Proposed TS 6.3.1, Facility Staff Qualifications
ML20069D452
Person / Time
Site: Millstone 
Issue date: 05/27/1994
From:
NORTHEAST NUCLEAR ENERGY CO.
To:
Shared Package
ML20069D451 List:
References
NUDOCS 9406030210
Download: ML20069D452 (4)


Text

-..

Docket No. 50-423 B14811 l

Millstone Nuclear Power Station, Unit No. 3 Proposed Revision to Technical Specifications Administrative Controls - Section 6 Marked Up Pages May 1994 9406030210 940527 PDR ADOCK 05000423 P

PDR

ADMINISTRATIVE CONTROLS 6.3 FACILITY STAFF OUALIFICATIONS 6.3.1 Each member of the facility staff shall meet or exceed the minimum 1

qualifications of ANSI N18.1-1971Mor comparable )ositions, except for the I

Health Physics Manager who shall meet or exceed tie qualifications of Regulatory Guide 1.8, Revision 1, May 1977.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff k

shall be maintained under the direction of the Senior Vice President -

o Millstone Station and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and 10 CFR Part 55.59. The Director-Nuclear Training has the overall responsibility for the implementation of the Training Program.

6.4.2 Deleted.

6.5 REVIEW AND AUDIT 6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC)

FUNCTION 6.5.1.1 The PORC shall function to advise the Nuclear Unit Director on all matters related to nuclear safety.

COMPOSITION i

6.5.1.2 The PORC shall be composed of the:

i Chairperson:

Nuclear Unit Director Vice Chairperson and Member:

Operations Manager Member:

Maintenance Manager

'Ie'...se r :

Instrument and Controls Manager Member:

Reactor Engineer is9ber:

Radiation Protection Supervisor or Chemistry Supervisor Member:

Engineering Manager Member:

Staff Engineer N fir 4he perlock e uck -Wree. gc.cs c<fH r % tSC voM c 6'f AmeNb"'*b NO-4t4. Opero-hows O f r wdl bc (>ermibc} h hoM MdA Senior re('t hr o p rc,4r h u ns t. At A sim ile r f'resvrireci W hr Ree}ct c4h+r j

4hm Ch(Irlow Und pJe 9aNd d Ws4 ope g & @nM os Osw b M shcu w.id c senior yoto og,4 ug,,g MILLSTONE - UNIT 3 6-5 AmendmentNo.7J,JJ,##,#

0193

Docket No. 50-423 B14811 1

1 Attachment 2

Millstone Nuclear Power Station, Unit No. 3 i

Proposed Revision to Technical Specifications Administrative Controls - Section 6 Retyped Pages a

2

.i May 1994 5

ADMINISTRATIVE CONTROLS 6.3 FACILITY STAFF OVALIFICATIONS 6.3.1 Each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971* for comparable positions, except for the i

Health Physics Manager who shall meet or exceed the qualifications of Regulatory Guide 1.8, Revision 1, May 1977.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction of the Senior Vice President -

Millstone Station and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and 10 CFR Part 55.59.

The Director-Nuclear Training has the overall responsibility for the implementation of the Training Program.

6.4.2 Deleted.

6.5 REVIEW AND AUDIT 6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC)

FUNCTION 6.5.1.1 The PORC shall function to advise the Nuclear Unit Director on all matters related to nuclear safety.

COMPOSITION 6.5.1.2 The PORC shall be composed of the:

Chairperson:

Nuclear Unit Director Vice Chairperson and Me'mber:

Operations Manager Member:

Maintenance Manager Member:

Instrument and Controls Manager Member:

Reactor Engineer Member:

Radiation Protection Supervisor or Chemistry Supervisor Member:

Engineering Manager Member:

Staff Engineer

  • For the period ending three years after the issuance of Amendment No.

, the Operations Manager will be permitted to have held a senior reactor operator license at a similar Pressurized Water Reactor other than Millstone Unit No. 3 and at least one of the Operations Assistant (s) shall hold a senior reactor operator license.

MILLSTONE - UNIT 3 6-5 Amendment No. JJ, J7, JJ, 79, 0267