CNEl-0400-25 Page 1 of 19 '

Rev.2 Catawba Unit 2 Cycle 7 Core Operating Limits Report May 1994 Duke Power Company P

DATE PREPARED BY:

M d f 3 (Ash

/4 A 94 7

0 $ %, k $, f

[k1,ff9' CHECKED BY:

<w g///'[ M 5/i 9/f y CHECKED BY:

APPROVED BY:

[k

( *,!f F QA CONDITION 1

)

NOTE This document does not contain information that affects the results and conclusions presented in the C2C7 Reload Report, Safety Analysis.

g601oOS2940523 p

ADOCK 05000414 I

PDR

,_ __._,_,,j

Catawba 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 Page 2 of 19 Rev.2 INSERTION SHEET Remove Insert pages 1-302, rev. I pages 1-19, rev. 2

)

I Y

I Catawba 2 Cycle 7 Core Operating Limits Rtport

- CNEl-0400-25 Page 3 of 19 Rev.2 i

REVISION LOG -

Revision Effective Date Comment OriginalIssue 15 February 1993 C2C6 COLR Revision 1 14 April 1994 C2C6 COLR rev.

l Revision 2 19 May 1994 C2C7 COLR I

I l

~

i l

/

k

Catawha 2 Cycle 7 Core Operating Limits Report -

CNEl-0400-25 Page 4 of 19 Rev.2 1

1.0 Core Operating Limits Report This Core Operating Limits Report (COLR) for Catawba Unit 2, Cycle 7 has been prepared in accordance with the requirements of Technical Specification 6.9.1.9.

The Technical Specifications affected by this report are listed below:

2.2.1 Reactor Trip System Instrumentation Setpoints 3/4.1.1.3 Moderator Temperature Coefficient 3/4.1.2.5 Borated Water Scurce - Shutdown 3/4.1.2.6 Borated Water Source - Operating 3/4.1.3.5 Shutdown Rod Insertion Limit 3/4.1.3.6 ControlRod Insertion Limit 3/4.2.1 AxialFlux Difference 3/4.2.2 Heat Flux Hot CharmelFactor 3/4.2.3 Nuclear Enthalpy Rise Hot Channel Factor 3/4.3.3.11 Boron Dilution Mitigation System 3/4.5.1.

Accumulators 3/4.5.4 Refueling Water Storage Tank 3/4.9.2 Instrumentation

/

i

Catawba 2 Cycle 7 Core Operating Limits Report CNEl-04@25 Page 5 of 19 Rev.2 1.1 Operating Limits The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using NRC-approved methodologies specified in Technical Specification 6.9.1.9.

2.0 Reactor Trip System Instrumentation Setpoints (Specification 2.2.1) 2.1 Overtemperature AT Setpoint Parameter Values Parameter Value Overtemperature AT reactor trip setpoint K = 1.1953 i

Overtemperature AT reactor trip heatup setpoint K = 0.03163/oF 2

penalty coefficient Overtemperature AT reactor trip depressurization K = 0.001414/ psi 3

setpoint penalty coefficient Measured reactor vessel AT lead / lag time t = 12 sec.,

i constants T = 3 sec.

i 2

Measured ATlag time constant T = 0 sec.

3 Measured reactor vessel average temperature T = 22 sec.,

4 lead / lag time constants -

t = 4 sec.

s Measured reactor vessel average temperature lag T = 0 sec.

)

6 time constant f (AI) " positive" breakpoint

= 3.0% AI i

f (AI) " negative" breakpoint

= -39.9% Al i

f (AI) " positive" slope

= 1.525% ATo/ % Al i

f (AI) " negative" slope

= 3.910% AT / % Al i

o

[

Catawba 2 Cycle 7 Core Operr. ling Limits Report -

CNEl-0400-25 Page 6 of 19 i

Rev.2 i

I 2.2 Overpower AT Setpoint Parameter Values i

Parameter Value i

i Overpower AT reactor trip setpoint K = 1.0819 4

j_

Overpower AT reactor trip heatup setpoint penalty K = 0.001291/aF 6

coefficient (for T > 590.8 *F) _

1 Overpower AT reactor trip heatup setpoint penalty K = 0.0/aF 6

i' coefficient (for Ts 590.8 @

Measured reactor vessel ATlead/lsg time t = 12 sec.,

i

{

constants T = 3 sec.

2 1

}

Measured ATlag time constant T = 0 sec.

3

\\

Measured reactor vessel average temperature lag 1 = 0 'sec.

6 j

time constant 1

Measured reactor vessel average temperature rate-1 = 10 sec.

7 lag time c'onstant i

i f (AI) " Positive" breakpoint

= 35.0% AI.

2 l

f (AI)" negative" breakpoint

= -35.0% AI 2

f (AI) " Positive" slope

= 7.0% ATg % AI 2

f (AI) " negative" slope

= 7.0% ATg % AI 2

m-w

1

. 1 Catawba 2 Cycle 7 Core Operating Limits Report CNEI-0400-25 Page 7 of 19 Rev.2 3.0 Moderator Temperature Coefficient (Specification 3/4.1.1.3) 3.0.1 The Moderator Temperature Coefficient (MTC) Limits are:

The MTC shall be less positive than the limits shown in Figure 1. The BOC, ARO, HZP MTC shall be less positive than 0.7

  • 104 AK/K/'F.

The EOC, ARO, RTP MTC shall be less negative that -4.l* 104 AK/K/ F.

3.0.2 For the MTC Surveillance Limit:

The 300 PPM /ARO/RTP MTC should be less negative than or equal to -3.2

  • 104 AK/K/ F, Where:

BOC stands for Beginning of Cycle EOC stands for End of Cycle ARO stands for All Rods Out HZP stands for Hot Zero (Thermal) Power

' RTP stands for Rated Thermal Power i

l e

~'

+

+,e..

,,,y

- Catawba 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 Page 8 of 19 Rev.2 1

0.9 --

0.8 --

Unacceptable Operation E 0.7 29 0.6 -.

.5g 0.5 --

s

  • y

.4 --

Acceptable Operation 1 0 t

g0.3--

0.2 --

0.1 -..

O O

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power

. Figure 1 i

Moderator Temperature Coefficient Versus Percent of Rated Thermal Power l

l i

G I

l

~

l l-I

Catawba 2 Cycle 7 Core Operating 1,imits Report CNEl-0400-25 Page 9 of 19 Rev.2 3.1 llornted Wnter Source - Shutdown (Specification 3/4.1.2.5) 3.1.1 Volume and b'oron concentrations for the Boric Acid Storage System and the Refueling Water Storage Tank (RWST) during modes 5 & 6:

Parameter Limit Boric Acid Storage System minimum boron 7,000 ppm concentration for LCO 3.1.2.5a Boric Acid Storage System minimum contained 12,000 gallons water volume for LCO 3.1.2.5a Boric Acid Storage System minimum water volume 585 gallons required to maintain SDM at 7,000 ppm Refueling Water Storage Tank minimum boron 2,175 ppm concentration for LCO 3.1.2.5b Refueling Water Storage Tank minimum contained 45,000 gallons.

water volume for LCO 3.1.2.5b Refueling Water Storage Tank minimum water 3,500 gallons volume required to maintain SDM at 2,175 ppm 1

/

l l

Catawba 2 Cycle 7 Core Operating Limits Report CNEl-tM00025 Page 10 of 19 j

Rev.2 3.2 llorated Water Source - Operating (Specification 3/4.1.2.6) 3.2.1 Volume and boron concentrations for the Boric Acid Storage System and the

- Refueling Water Storage Tank (RWST) during modes 1,2,3, & 4:

1 Parameter Limit Boric Acid Storage System minimum boron 7,000 ppm concentration for LCO 3.1.2.6a i

Boric Acid Storage System minimum contained 22,000 gallons water volume for LCO 3.1.2.6a Boric Acid Storage System minimum water volume 9,851 gallons required to maintain SDM at 7,000 ppm Refueling Water Storage Tank minimum boron 2,175 ppm

]

concentration for LCO 3.1.2.6b Refueling Water Storage Tank minimum contained 363,513 gallons water volume for LCO 3.1.2.6b l

Refueling Water Storage Tank minimum water 57,107 gallons volume required to maintain SDM at 2,175 ppm 3.3 Shutdown Rod Insertion Limit (Specification 3/4.1.3.5) 3.3.1 The shutdown rods shall be withdrawn to at least 222 steps.

3.4 Control Rod Insertion Limits (Specification 3/4.1.3.6) 3.4.1 The control rod banks shall be limited to physical insertion as shown in Figure 2.

3.5 Axial Flux Difference (Specification 3/4.2.1) 3.5.1 The Axial Flux Difference (AFD) Limits are provided in Figure 3.

~

Catawba 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 Page 11 of 19 -

Rev.2

[^

Fully Withdrawn (29.1 %,230)

(Maximum = 230)\\ (79.6%,230) 220 -=-------

Fully Withdrawn -

f 200 -

(Minimum = 222)

/ HANKB

- 180 - -

(100 %,161)

-160 --(0%,163)

G g140-g BANK C a 120 -

[100--

8 y 80 --

BANK D

.E 60 --/

.g

/

ca 40 -.(0%,47) 20 - -

Fully Inserted (30%,0) o 0

10 20 30 40 50 60-70 80 90 -

100 I

Percent of Rated Thermal Power l

Figure 2-Control Rod Bank Insertion Limits Versus Percent of Rated Thermal Power L

t i.

I 1

s

I-L Catawba 2 Cycle 7 Core Operating Limits Report

- CNEl.0400,25 Page 12 0f 19 Rev.2 I

i

,f

( 17,100)

(+ 10,100)

, rm Unaccepubic Operation l g,,

~

~

Unaccepuble OperaGon 70 --

Acceptable Operation A

60 --

30 --

(-36,50)

(+21,50) 3 40 --

Il

.E 30 --

l l

20 --

10 --

i f

R f

I n

f I

I f

E 5

5 5

5 4

4 8

-50

-40

-30 20 10 0

10 20 30 40 50 l

Axial Flux DiNerence (% Delta I)

Figure 3 Percent of Rated Thermal Power Versus Axial Flux Difference Limits l

l l

i 1

I

Catawba 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 Page 13 of 19 Rev.2 3.6 IIcat Flux Ilot Channel Fnctor, F (X,Y,Z) (Specification 3/4.2.2)

Q F[ = 2.32 3.6.1 3.6.2 K(Z) is provided in Figure 4 for Mark-BW fuel.

3.6.3 K(Z) is provided in Figure 5 for OFA fuel.

The following parameters are required for the Surveillance Requirements of T.S. 3/4.2.2:

Ph(X,Y,Z)

  • Mg(X,Y,Z) 3.6.4 [F (X,Y,Z)]OP =

q

[Fh(X,Y,Z)]OP cycle dependent maximum allowable design where:

=

peaking factor which ensures that the F (X,Y,Z) q limit will be preserved for operation within the LCO limits. [Fj(X,Y,Z)]oP includes allowances for calculational and measurement uncertainties.

the design power distribution for Fq. ((X,Y,Z)

(X,Y,Z)

=

is provided in Table 1, Appendix A for normal operation and Table 2, Appendix A for power escalation testing during initial startup.

M (X,Y,Z) the margin remaining in core location X,Y,Z to

=

n the LOCA limit in the transient power distribution. M (X,Y,Z) is provided in Table 1, n

Appendix A for normal operation and Table 2, Appendix A for power escalation testing during l

initial startup.

l Measurement Uncertainty, = 1.05.

l UMT

=

Engineering Hot Channel Factor, = 1.03.

MT

=

Peaking penalty that accounts for allowable TILT

=

quadrant power tilt ratio of 1.02, = 1.035.

NOTE: [E(X,Y,Z)]OP is the parameter identified as [q (X,Y,Z) in DPC-NE-2011PA.

q l

l

Catawba 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 Page 14 of 19 i-Rev.2 (X,Y,Z)

  • M (X,Y,Z)

C 3.6.5 [E(X,Y,Z)]RPS =

q where:. [IE(X,Y,Z)]RPS cycle dependent maximum allowable - design

=

q

~

l peaking factor which ensures that the centerline i

fuel melt limit will be preserved for all' operation.

((q(X,Y,Z)]RPS includes -

allowances for calculational and measurement uncertainties.

}

D F (X,Y,Z) the design power distributions for Fq.

(X,Y,Z)-

=

q 1

is provided in Table 1, Appendix A for normal operation and Table 2,. Appendix-A for power escalation testing during initial startup.

M (X,Y,Z) the margin remaining to the CFM limit in core c

=

location - X,Y,Z from _ the transient'. power distribution. M (X,Y,Z) calculations parallel the c

M (X,Y,Z) calculations described in DPC-NE-n 20llPA, except that the LOCA limit is replaced with the CFM limit. M (X,Y,Z) is provided in c

Table 3, Appendix A for normal operation and Table 4, Appendix A for power escalation testing-during initial startup.

Measurement Uncertainty,: = 1.05.

UMT

=

Engineering Hot Channel Factor, = 1.03.

MT

=

TILT

= ' Peaking penalty' that accounts for allowable quadrant power tilt ratio of 1.02, = 1.035.

NOTE: [lE(X,Y,Z)]RPS is simihr to the parameter identified as [q (X,Y,Z) in n

DPC-NE-2011PA except that M (X,Y,Z) replaces Mg(X,Y,Z).

C KSLOPE = adjustment to the K value from OTAT required to compensate for 3.6.6 i

each 1% that [k(X,Y,Z)]RPS exceeds it limit, = 0.0725 q

?%.'

Catawha 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 3'

Page 15 of 19 l

Rev.2-

'a t

4 1.2 a

~

j.

(0.0,1.00)

(8.0.1.00)

{

l-(10.8,0.94)

I

~

1 i

]

0.8 e

F 1>

E 0.6 (12.0.0.647) 3 x

4 4

0.4 4

I i

i 0.2 4-i i

c c

r O

0 1

2 3

4 5-

'6 7-8 9

10 11

- 12 l

Core Height (ft) ii j

j Figure 4 K(Z), Normalized F (X,Y,Z) as a Function of Core Height for MkBW Fuel Q

i t

4 F

b i.

e

~-

"f Catawba 2 Cycle 7 Core Operating Limits Report CNEl-0400-25 Page 16 of 19

-Rev.2 1

1.2 (6.0,1.00)

(0.0,1.00) 1 (10.8,0.94)

~

l 0.8 l

(12.0,0.647) 80.6

.m

. \\

O,4' 0.2 l

0 0

1 2

3 4

5 6

7-8 9

10 11-12 I

Core Height (ft)

~l Figure 5 I

K(Z), Normalized F (X,Y,Z)as a Function of Core Height for OPA Fuel Q

i l

l i

L

Catawba 2 Cycle 7 Core Operating Limits Report CNEl.0400-25 Page 17 of 19 Rev.2 3.7 Nuclear Enthalpy Rise IIot Channel Factor, FAlI(X,Y,Z) (Specification 3/4.2.3)

The following parameters are required for the LCO Requirements of T.S. 3/4.2.3:

1

~

3.7.1 [ F[,(X, Y)]"

= MARP (X,Y)

  • 1.0 + RRH * (1.0 - P) where:

MARP(X,Y) = Catawba 2 Cycle 7 Operating Limit Maximum Allowable Radial Peaks, (M ARP(X,Y)) is provided in Table 7, Appendix A for non-axial blanket fuel and in Table 8, Appendix A for axial blanket fuel.

Thermal Power p

  • Rated Thermal Power RRH is defined in section 3.7.3 The following parameters are required for the Surveillance Requirements of T.S. 3/4.2.3:

[F[,(X,Y)]SURV = F[,(X,Y)x Mm(X,Y) 3.7.2 UMR x TILT where: [F[,(X,Y)]S*V cycle dependent maximum allowable design peaking

=

factor which ensures that the FAH(X,Y) limit will be preserved for operation within the LCO limits.

[F[,(X,Y)]S*" includes allowances for c!cuhtional and measurement uncertainties.

F,(X,Y) = the design power distribution for FAH. F,(X,Y) u u

is provided in Table 5, Appendix A for nomial operation and Table 6, Appendix A for power j

escalation testing during initial startup.

MAH(X,Y) = the margin remaining in core location X,Y to the Operadonal DNB limit in the transient power l

distribution. MAH(X,Y) is provided in Table 5, Appendix A for normal operation and Table 6, Appendix A for power escalation testing during initial startup.

UMR = Uncertainty value for measured radial peaks, = 1.04.

l TILT = Peaking penalty that accounts for allowable quadrant power tilt ratio of 1.02, = 1.035.

l l

l l

r l

Catawha 2 Cycle 7 Core Operating Limits Report CNEl 0400-25 Page 18 of 19 Rev.2 NOTE: [Fh(X,Y)]"" is the parameter identified as F7(X,Y) in DPC-NE-20llPA.'

3.7.3 RRH = Thermal Power reduction required to compensate for each 1% that FAH(X,Y) exceeds its limit, = 3.34.

TRH = Reduction in OTAT K setpoint required to compensate for each 3.7.4 1

1% that FAH(X,Y) exceeds its limit, = 0.04 i

3.8 Boron Dilution Mitigation System (Specification 3/4.3.3.11) l 3.8.1'. Reactor Water Makeup Pump flowrate limits:

Applicable Mode Limit Mode 3 or 4 s 150 gpm -

Mode 5

$ 70 gpm 3.9 Accumulators (Specification 3/4.5.1).

3.9.1 Boron concentration limits during modes 1,2 and 3:

Parameter Limits Cold Leg Accumulator minimum boron 2,000 ppm concentration for LCO 3.5.1c Cold Leg Accumulator maximum boron

'2,275 ppm concentration for LCO 3.5.lc Minimum Cold Leg Accumulator boron 1,900 ppm l

concentration required to ensure post-LOCA subcriticality 3.10 Refueling Water Storage Tank (Specification 3/4.5.4) 3.10.1-Boron concentration limits during modes 1,2,3 and 4:

Parameter jlmits Refuelir.g Water Storage Tank minimum boron 2,175 ppm concentration for LCO 3.5.4b 1.

,~,..

.. _,. _ - _. -. - -., _, _.. -.. -... - -.. ~..

~ -,.

. ~

Catawba 2 Cycle 7 Core Operating Limits lleport CNEl-04GO-25 Page 19 of 19 Rev.2 1

Refueling Water Storage Tank maximum boron 2,275 ppm concentration for LCO 3.5.4b 1

3.11 Instrumentation (Specification 3/4.9.2) 3.11.1 Reactor Makeup Water Pump Flowrate Limit:

- Aoolicable Mode Limits Mode 6 370 gpm

  • - Values provided as Tables in the Appendix to this document were generated in the C2C07 Maneuvering Analysis calculational file (CNC-1553.05-00-0177). The CNS Reactor Engineering Group will control this information via computer file (s) and should be contacted if there is a need to access this information.

1 e

4 l

w n,-ase

,-~e-w.,

n w w w --. n e

~<m.e--

r,

-r,-e

)

Catawba 2 Cycle 7 Core Operating Limits Report Appendix A

Catawba 2 Cycle 7 Core Operating Limits Report Page 1 of 144 Appendix A i

TABLE 1 1

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 100% POWER, 4 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOH)

)

e e e e e e e e e s e. e. e e.... e e........ e e e e e e e e e e e e.......C........B.. e e. e. e e e e e e.

H G

F E

D A

8*

.4038 *

.3010 *

.5698 *

.3534 *

.5741 *

.6587

  • 6190 *

.4819

  • e.2. 7133.*.3. 8753..*.2. 1069..esa. 3. 3818
  • 2 0799.*.1. 7983.*.1. 9195.*.2. 4357..*

e**e 9*

.3010 *

.5162 *

.3438 *

.6051 *

.3866 *

.6330 *

.6340 *

.4263 *

  • 3. 8753.*.2. 3085..*.3. 4776.*.1. 9691
  • 3.0699 1.8809
  • 1.8613
  • 2.7608
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10 *

.5698 *

.3438 *

'.5912 *

.3620 *

.6126 *

.6426 *

.5858 *

.2431 *

  • 2. 1069.*. 3. 4700.*.2. 0088.*.3 2775.*eee.9336
  • 1.8292
  • 2 0165
  • 4. 8121.*

1

. e eeeeeeeeeeeeeeeee eeeeee.

q 11 *

.3534 *

.6083 *

.3631 *

.5751 *

.3695 *

.5944 *

.5580 *

.4014 *

  • 3.3818
  • 1.9621
  • 1 eeeeeeeeeeeeeeee**e 3. 2650.*.1. 9864
  • 3.0690.*eee.9215
  • 2.0741
  • 2.9059 *

..eeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeee 12 *

.5741 *

.3888 *

.6148 *-.3706 *

.5708 *

.5494 *

.4948 *

  • 2. 079.9.*.3. 0521
  • i. 9265.*.3. 0631..*.1. 8742..*.1 9472..*.2. 2.984.*.

e.

13 *

.6587 *

.6351 *

.6437 *

.5965 *

.5516 *

.5034 *

.3395 *

. 1. 7983..*. 1 8742..*.1. 8250.*. 1. 9160.*.1 9424.*.2. 1069.*.3. 2970..*

14 *

.6190 *

.6340 *

.5869 *

.5591 *

.4969 *

.3459 *

  • 1.9195
  • 1.8610
  • 2. 0118..*. 2. 0686.*. 2. 2884
  • 3. 2305.*.
  • eeeeeeeeeeeeeeee...

15 *

.4819 *

.4252 *

.2442 *

.4027

  • 2. 4357..*. 2. 7615
  • 4. 8099
  • 2. 8961.* M-SUB-Q AT 100% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 2 = BOTTOM)

H Q

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8*

.6019 *

.8439 *

.8429 *

.9350 *

.8172 *

.9018 *

.9221 *

.7818

  • 2.4061
  • 1.7691
  • 1.7902
  • 1.60 eeeeeeeeeeeeeeeeee.eeeeeeeeeeeee.49..*. 1. 8292
  • 1.6455
  • 1.6102
  • 1.8501
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9 *

.8439 *

.7518 *

.9168 *

.8750 *

.9735 *

.9414 *

.9168 *

.6372 *

. 1. 7. 6 91.. *. 1. 9 911. *. 1 6 3 9 7.. *.1 717 9.. *. e. 5 2 9 3

  • 1. 57 8 8. *.1.

6.14 3.. *. 2. 3127.. *.

1.......

10 *

.8429 *

.9178 *

.8857 *

.9457 *

.9114 *

.8996 *

.8836 *

.7090 *

  • 1.7902
  • 1.6371
  • 1.6957
  • 1.5624
  • 1.6344
  • 1.6538
  • 1.6751
  • 2.0691
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11 *

.9350 *

.8782 *

.9478 *

.8172 *

.9553 *

.8889 *

.8643 *

.6094 *

  • 1.6049
  • 1.7120 8 1 5601
  • 1 7971..*. 1 5377...*.1 6523.*.1. 6868..*e.2. 4066
  • e *eeseseeeeeeeeeeeen

)

12 *

.8172 *

.9778 *

.9157 *

.9585 *

.8750 *

.8718 *

.7s40 *

  • 1.e.8292
  • 1.5223eeeeeeeeeeeeee. 1. 6277..*.1. 5330
  • 1.6100
  • 1 6316
  • 1.8429

..eeeeeeeeeeeee *eeeeeeeeeeeeee 13 *

.9018 *

.9446 *

.9029 *

.8911 *

.8739 *

.8397 *

.5205

  • 1 e.1. 6 4 5 5. ** e e e. 57 51.. *. 1. 6. 4 6 9.. *.1 e. 6 4 6 9
  • 1. 6 2 6 3
  • 1. e. 6 7 9 4
  • 2. 7 4 9 2
  • e.

eeeeeeeeeeeeee..

eeeeeeeeeee.ee.

14 *

.9221 *

.9178 *

.8857 *

.8664 *

.7883 *

.5323 *

. 1. 6102..*. 1. 6127..*.1. 6709..*.1 6821..*. 1. 8356

  • 2. 6885
  • 15 *

.7818 *

.6362 *.7101 *

.6105

  • 1. 8 8 01..*. 2. 3131. *. 2. 0 6 5 0. *. 2. 3 9 8 0..
  • M-SUB-Q eeeeee..

ee...

eeeeee.

i i

i

~,

Catawha 2 Cycle 7 Core Operating Limits Report Page 2 0f 144 Appendix A TABLE 1'(CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F*SUB-Q OP MARGIN) - NORMAL OPERATION l

AT 100% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 i

(LEVEL 18 e TOP OF CORE, LEVEL 1 m BOTTOM) i H

G E

s e e e e e e e e e e e e e e e e e e... F... e e e e e e e........ D.........C.........B......... A......

t f

8 *

.7872

  • 1.1096
  • 1.0967
  • 1.2038
  • 1.0207
  • 1.1138
  • 1.1203 *

.9789 *

  • 2. 0796.*..1 4847..*. 1. 5108.*. 1. 3679...*.1 6036
  • 1.4724
  • 1.4571
  • 1.6497
  • e.

..eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.1096 *

.9660

  • 1.1984
  • 1.1278
  • 1.2209
  • 1.1599
  • 1.1310 *

.7679

  • eeeeeeeee. 4127
  • 1.43891.. eeeeeeeeeee*eee.0991
  • 2
  • 1.4847
  • 1.6979
  • 1.3778
  • 1.4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.643.*. 1.3414
  • e eeeee.

10

  • 1.0967
  • 1.1995
  • 1.1513
  • 1.2252
  • 1.1449
  • 1.1341
  • 1.0892 *

.9039

  • l

. 1. 5108 *

... 1. 3767..*. 1. 4349.*e. 3328

  • 1. 4302.*ee. 44,1..... *. 1. e. 4 9 6 9. e *e.1. 7 8 5 4. *.

1

.ee.

ee.

ees 11

  • 1.2038
  • 1.1320
  • 1.2274
  • 1.0389
  • 1.2252
  • 1.1149
  • 1.0935 *

.7658 *

  • 1.3679
  • 1.460 1.4602
  • 1.4754
  • 2.1080
  • eeeeeeeeeeeeeee.2...*.1. 3311..*.1. 5648
  • 1.3302
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.0207
  • 1.2263
  • 1.1503
  • 1.2274
  • 1.1460
  • 1.1299 *

.9853 *

  • 1.6036
  • 1.3354
  • 1.4252
  • 1.3302
  • 1.4107
  • 1.4221
  • 1.6331
  • esseeeeeeeeeeeeeeeeseeeeeeeeee***eeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13
  • 1.1138
  • 1.1652
  • 1.1374
  • 1.1181
  • 1.1331
  • 1.0817 *

.6362 *

  • 1.4724
  • 1.4078
  • 1.4399
  • 1.4552 *'1.4174
  • 1.4807
  • 2.5051
  • f eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-14
  • 1.1203
  • 1.1331 + 1.0913
  • 1.0967 *

.9896 *

.6512

  • eeeeeeeeeeeeeeeeeeeeeee.36
  • 1.4703
  • 1.6255
  • 2.44581.4571
  • 1.4369
  • 1.49..eeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.9789 *

.7668 *

.9061 *.7679

  • F-SUB-Q e.1. 6 4 9 7.. *.2.1012.. *.1.7 810
  • 2. 1015. *e N-SUB-Q j

j l

t AT 100% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 l

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.9136

  • 1.3045
  • 1.2809.* 1.4019
  • 1.1717
  • 1.2809
  • 1.2745
  • 1.1224
  • 1.8873
  • 1.3336 *
1. 3614.*.1 2377..*.1. 4.635.*. 1 3476..*.1. 3486..*. 1 5159..*

eeeeeeeeeeeeeeee....

9

  • 1.3045
  • 1.1224
  • 1.4052
  • 1.3120
  • 1.4126
  • 1.3302
  • 1.2981 *

.8686

  • 1 e.1. 3 3 3 6. *.1.5 3 2 9..*.1.2 3 7 7..
  • e e e. 3 2 7 5.. *. 1. 2 2 2 8.. *. 1 2 9 9 7.. *.1 3 216..*.1.

9 4 41.

  • e e

10

  • 1.2009
  • 1.4062
  • 1.3420
  • 1.4319
  • 1.3238
  • 1.3088
  • 1.2456
  • 1.0421 o
  • 1. 3614..*.1 2363..*. 1 2980.*.1 2061.*. 1. 3069..*.1. 3191.*. 1 3794 *... 1.6328.*.-

I 11

  • 1.4019
  • 1.3152
  • 1.4341
  • 1.2027
  • 1.4309
  • 1.2863
  • 1.2659 *

.8782 *

  • 1.2377
  • 1.32 1
  • eeeeeeeeeeeee.32 *e**.2040
  • 1.4228
  • 1.2067 8 1.3?te
  • 1.3476 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee,.eeeee.. 1. 9425

  • 12
  • 1.1717
  • 1. 4191
  • 1. 3 2 91
  • 1. 4 3 41 + 1. 3 2 80
  • 1. 3163
  • 1.13 63 ' *
  • 1.4635
  • 1.2172
  • 1.3020
  • 1.2040
  • 1.2941
  • 1.2980
  • 1.5019 ~*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.2809
  • 1.3355
  • 1.3152
  • 1.2906
  • 1.3205
  • 1.2541 *

.7229

  • 2 e.1. 3. 47 6.. *. 1. 2 9 4 9. *. 1. 313 4.. *.1 3 3 41.. *. 1. 2 9 3 3. *.1.

3 5 81.. *. e e 3 2 9 5 *

.. ee eee.

14

  • 1.2745
  • 1.3002
  • 1.2488
  • 1.2702
  • 1.1417 *

.7411 *

  • 1.3486
  • 1.3198
  • 1.3759
  • 1.3426
  • 1. 4945.*. 2. 2714 *
      • eeeee**eeeeeeeeeeeeeeeeeeeeee......

15

  • 1.1224 *

.8675

  • 1.0442 *

.8814

  • 1.5159
  • eeeeeeeeeee. 9474 *1..... 1. 6290.*.1. 9353..*. M-SUB-Q I

I t

l i

t I

l l

~

Catawba 2 Cycle 7 Core Operating Limits Report Page 3 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 100% POWER, 4 BPPD, THIS IS LEVEL 14 OF.18 (LEVEL 18 = TOP OF CORE,' LEVEL 1 = BOTTOM) e...H.........G.........F.....e...E.........D.........C.........B.........A......-

)

B*

.9757

  • 1.4062
  • 1.3762
  • 1.5069
  • 1.2477
  • 1.3720
  • 1.3559
  • 1.1963 *

. 1. 8672..*.1. 311.4.*. 1. 3445.*.1. 2205.*. 1 4493.*.1. 3356.*. 1 3448.*. 1. 5105.*.

9* 1.4062

  • 1.2006
  • 1.5155
  • 1.4052
  • 1.5219
  • 1.4180
  • 1.3880 *

.9178 *

  • 1. 3.114.*.1. 5112..*. 1. 2.170
  • 1. 3143..*.1. 2009.*.1. 2937..*.1 3119.*.1 9420.*.

e.

.es.

10

  • 1.3762
  • 1.5176
  • 1.4373
  • 1.5422
  • 1.4180
  • 1.4052
  • 1.3270
  • 1.1117
  • 1.3038
  • 1.3755
  • 1.6260
  • e.1. 3445.*.1. 2156..*.1. 2844
  • 1.1994
  • 1 2970
  • eeeeeeeeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5069
  • 1.4084
  • 1.5455
  • 1.2852
  • 1.5412
  • 1.3752
  • 1.3559 *

.9318 *-

e.1. 2205.*. 1. 3104.*. 1 1974

  • 1.4059
  • 1.1901
  • 1.3300
  • 1.3371
  • 1.9451 *

...eeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12 *'1'2477

  • 1.5203
  • 1.4244
  • 1.5444
  • 1.4212
  • 1.4137
  • 1.2124 *
  • 1. 4.493.*. 1. 2020.*.1. 2914.*.1 1074.*. 1. 2875..*. 1. 2860.*. 1 4989.*'

j e.

13

  • 1.3720
  • 1.4234
  • 1.4116
  • 1.3805
  • 1.4180
  • 1.3430 *

.7658 *

. 1. 3356.*.1. 2.003..*.1. 2983..*. 1 32.50.*. 1. 28.14 *... 1. 3532..*.2. 3307..*

i 14

  • 1.3559
  • 1.3902
  • 1.3302
  • 1.3612
  • 1.2188 *

.7850

  • e.1 3448.*. 1. 3101..*.1 3715.*.1. 3321..*.1. 4906.*.2. 2726
  • e***

15

  • 1.1963 *

.9168

  • 1.1130

. 1 5105.*.1 9438.*.1 6224.*. 1. 9365.* M-SUB-Q r

AT 100% POWER, 4 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON)'

    • e.H.........G........F.........E.........D.........C.........B........A......

B

  • 1.0560
  • 1.5315
  • 1.5005
  • 1.6408
  • 1.3559
  • 1.4908
  • 1.4737
  • 1.3023 *

. 1. 8255

  • 1 2817..*.1 3122..*.1 1935.*.1 4.114.... 1. 3090..*. 1. 3170.*.1 4772..*e l

9

  • 1.5315
  • 1.3066
  • 1.6526
  • 1.5315
  • 1.6579
  • 1.5422
  • 1.5101 *

.9950

  • i
1. 2 817..*. 1 47 0 6..*. 1. 18 8 3.*.
1. 2 8 4 8.*e e e e.1817
  • 1. 2 67 4
  • 1. 2 8 4 0
  • 1. 8 9 8 0
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10
  • 1.5005
  • 1.6536
  • 1.5658
  • 1.6804
  • 1.5444
  • 1.5294
  • 1.4416
  • 1.2081
  • e.1. 3122..*.1. 1869..*. 1. 2570.*. 1. 1651..*.1. 2711.e*eeee.2772
  • 1.3493
  • 1.5943
  • 1 eeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.6408
  • 1.5337
  • 1.6847
  • 1.3987.* 1.6793
  • 1.4983
  • 1.4791
  • 1.0100 *

..1 1935

  • 1.2817
  • 1.1626
  • 1.3718 1.1657
  • 1.3059
  • 1.3114'*

eeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee........... 1. 9152..*

12

  • 1.3559 *'1.6654
  • 1.5519
  • 1.6836
  • 1.5476
  • 1.5422 8 1.3195'8
  • 1. 4114.*.1. 1766.*.1. 2651..*.1. 1632..*. 1. 2649.*. 1. 2612..*. 1. 4731.*.

e.

13

  • 1.4908
  • 1.5487
  • 1.5369
  • 1.5037
  • 1.5476
  • 1.4641 *

.8290 *

. 1.3090.*. 1. 2622..*. 1 2711..*. 1. 3003.*. 1 2568..*.1 3282..*.2. 2905.*.

e**ee.

14

  • 1.4737
  • 1.5133.* 1.4459
  • 1.4844
  • 1.3270 *

.8504 *

. 1 3170..*. 1 2817..*. 1 3456.*.1. 3059..*.1. 4651.*. 2. 2325..*

)

15

  • 1.3023 *

.9939

  • 1.2113
  • 1.0142
  • 1.4772
  • 1.8997
  • 1.5908
  • 1.9084
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee w

i 1

c-c

Catawba 2 Cycle 7 Core Operating Limits Report Page 4 of 144 j

Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-8UB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION i

AT 100% POWER, 4 EFPD, THIS IS LEVEL 12 OF 18 i

(LEVEL 18 = TOP OF CORE, LEVEL 1 s BOTTOM)

)

i H

0 F

E C

_ A

e. e e e e e e e e e e e e e e e e e.e e e e e e e e e e e e e e e e e e.D........e e e e e e e e e.B......e e e e e e e e.

)

8e 1.0903

  • 1.5947
  • 1.5604
  • 1.7104
  • 1.4084
  • 1.5530
  • 1.5337
  • 1.3559 1.3355
  • 1.3455
  • 1.5085 *

)

. 1. 8820

  • 1. 3065.*. 1. 3396.*. 1. 2156..*. 1. 4478
  • i ee

.ee.........

eeeeeeee.........

9

  • 1. 5 9 47
  • 1. 3 559
  • 1.7 2 4 3 a 1.5926
  • 1.7307
  • 1.6044
  • 1.5744
  • 1.0303
  • 1.3121
  • 1.2021
  • 1.2948
  • 1.3089
  • 1.9513 *

. 1.3065

  • 1.5075
  • 1.2008
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeee.

1 10

  • 1.5604
  • 1.7254
  • 1.6279
  • 1.7543
  • 1.6C76
  • 1.5958
  • 1.4994
  • 1.2552
  • e.1. 3396.*. 1. 207.5.*. 1 2833..*. 1 1850e*eee.2963
  • 1.3002 *.1.3789
  • 1.6312
  • 1 e

eeeeeeeeeeeeeeeeeeeeee**eeeeeeen.

11

  • 1.7104
  • 1.5958
  • 1.7596
  • 1.4555
  • 1.7522
  • 1.5594
  • 1.5412-*'1.0442
  • l 1.2156
  • 1.3081
  • 1.1824
  • 1.4028'* 1.1857
  • 1.3314
  • 1.3355
  • 1.9675
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene-1.7393
  • 1.6151
  • 1.7575
  • 1.6097
  • 1.6097
  • 1.3720
  • J 12
  • 1.4084
  • 1.4478
  • 1.1968
  • 1.2909
  • 1.1831
  • 1.2909
  • 1.2833
  • 1.5053
  • eeeeeeee.**eeeee***eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13
  • 1.5530 *-1.6108
  • 1.6033
  • 1.5658
  • 1.6161
  • 1.5251'*

.8579

  • f
  • 1.3355
  • 1.2894
  • 1.2940
  • 1.3265
  • 1 2787..*. 1. 3547..*. 2. 3567.*

1 1

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.......

14

  • 1.5337
  • 1.5776
  • 1.5037
  • 1.5487
  • 1.3805 *

.8804 *

. 1. 3 4 5 5. *.1.3 0 6. 5.' *.1.

37 4 5.. *.1.3 2 9 8

  • 1 4 9 7 0..
  • e 2 9 5 5.
  • 2 15
  • 1.3559
  • 1.0292
  • 1.2584
  • 1.0496
  • 1. 50 8 5
  • 1. 9 531
  • 1. 627 5
  • 1. 9 58 6
  • N-SUB-Q -

1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*

AT 100% POWER,-

4 BFPD, THIS IS LEVEL 11 OF 18 (LEVEL 10 m TOP OF COPE, LEVEL 1 s BOTTON)

H G

F

.E D.

.C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8* 1.1010

  • 1.6268
  • 1.5894
  • 1.7489
  • 1.4330
  • 1.5872
  • 1.5658
  • 1.3837 *
  • 1.9734
  • 1.3497
  • 1.3877
  • 1.2558
  • 1.5160
  • 1.3797
  • 1.3913
  • 1.5584 *

)

eseeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

9

  • 1.6268
  • 1.3773
  • 1.7629
  • 1.6226
  • 1.7714
  • 1.6354
  • 1.6108
  • 1.0464
  • i 1

I

. 1. 3 4 9 7..*. 1 57 9 9. e' *e.1.

2. 4 8 5
  • 1. 3 5 9 8.. *e s. 2 414
  • 1 3 421.*.1.

3 513.. *

  • 2. 0 3 9 2. e *e l

e.

.ee..

eeee.ee

... *seee 10

  • 1.5894
  • 1.7650
  • 1.6590
  • 1.7950
  • 1.6397
  • 1.6333
  • 1.5203
  • 1.2777
  • e.1. 3 87 7..*. 1. 2 471..*. 1. 3 314.*. 1. 2 2 52.. *. 1. e. 3 4 4 6
  • 1. 3 4 3 8
  • 1. 4 2 9 8
  • 1. 6 8 8 4
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7489
  • 1.6268
  • 1.8004
  • 1.4844
  • 1.7939
  • 1.5904
  • 1.5754
  • 1.0581
  • i
  • 1.2558
  • 1.3564
  • 1.2225
  • 1.4692..*. 1 2259.*. 1. 3833
  • 1.382.4.*. 2. 0474..*.

]

eseeeeeeeeeeeeeeeeeeeeeeeeeeeemen.

.eeseeee.

12 + 1. 43 3 0

  • 1.7 8 00
  • 1. 6 4 8 3
  • 1.7 9 9 3
  • 1. 6 418
  • 1. 6472
  • 1. 3 9 6 6
  • e 1. 516 0
  • 1. 2 3 57. *. 1. 33 8 0
  • 1. e. 22 31
  • 1. 3 4 21
  • 1. 3 3 06
  • 1. 56 63
  • ee....eeeeeeee

.ee..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.-

13

  • 1.5872
  • 1.6429
  • 1.6418
  • 1.5969
  • 1.6547
  • 1.5572 *

.8686 *

. 1. 37 9 7.. *. 1. 3 3 6 3. *.1.

3 3 7 2 e *e e e e. 3 7 71.. *. 1. 3 2 4 9 1.4085.+.2. 4816

  • 1 e

14

  • 1.5658
  • 1.6140
  • 1.5326
  • 1.5829
  • 1.4062 *-.8921 *
  • 1.3913
  • 1.3488
  • 1.4251
  • 1.3762
  • 1.5562
  • 2.4171
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.3837
  • 1.0453
  • 1.2809
  • 1.0635
  • F-SUB-Q eeeeeee... 2. 0411..*. 1. 6844
  • 2. 0378..* M-SUB-Q
  • 1.5584
  • e 4

e

,-i

l Catawba 2 Cycle 7 Core Operating Limits Report Page 5 of 144 Appendix A TABLE 1 (CONTINUED)

F-8UB-Q E M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 100% POKER, 4 BFPD, THIS IS LEVEL 10 OF 18 (LEVVL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1299
  • 1.6804
  • 1.6451 *. 1.8132
  • 1.4812
  • 1.6451
  • 1.6268
  • 1.4362 *
  • 1.9882
  • 1.3430
  • 1.3789 *
  • 1.3771
  • 1.3957
  • 1.5618 *
    • eeeeeeeeeeeeeeeeeeeeeeeee. 1. 2492.*. 1.5213 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6804
  • 1.4201
  • 1.0282
  • 1.6815
  • 1.8378
  • 1.6965
  • 1. 129
  • 1.0817 *

]

. 1. 3430.*. 1. 5827..*.1. 2414..... 1. 3530.*.1. 2364.*.1. 3421..*.1. 356.... : 4.2.,07 02..

  • i 10
  • 1.6451 *-1.0303
  • 1.7179
  • 1.8635
  • 1.7007
  • 1.6965
  • 1.5840
  • 1.0116
  • 1 2400..*. 1. 3249.*.1. 2211
  • 1. 3405.* 1.3430
  • 1.4393
  • 1. 70.14
  • 1.3789 *

. ee

.ee.

... eeeeeeeeeeeeeeeee.

eeeeee....

11

  • 1.8132 + 1.6847
  • 1.8689
  • 1.5390
  • 1.8625
  • 1.6504 + 1.6376
  • 1.0913 a e.1. 2. 4 9 2.. *. 1. 3 5 0 5. *.1.

219 0.. *. 1 47 5 5. *.1 2 2 31.. *.1.

3 8 8 6.. *. 1 3 9. 57.. *. 2. 07 0 9 12

  • 1,4812
  • 1.8475
  • 1.7093
  • 1.8689
  • 1.7029
  • 1.7136
  • 1.4469 *
  • 1.5213
  • 1.2301
  • 1.3339
  • 1.2197
  • 1.3480
  • 1.3388
  • 1.5835
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6451
  • 1.7050
  • 1.7040
  • 1.6579
  • 1.7200
  • 1.6172 *

.8954

  • eeeeeeeeee.1. 3363.*. 1. 3355.*.1 3824
  • 1.3330
  • 1.4205
  • 2.5438 *
  • 1.3771
  • ee.

........eeeeeeeeeeeeeeeeeeeeeeeeen.

14

  • 1.6268
  • 1.6761
  • 1.5894
  • 1.6451
  • 1.4576 *

.9200

  • 1.4346
  • 1.3895
  • 1.5731
  • 2.4767 *
  • 1. 3957.*.1.3530 *

.....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.4362
  • 1.0806
  • 1.3259
  • 1.0967

. 1. 5618..*. 2. 0722..*.1. 6976.*.2. 0630..* M-8UB-Q e**e AT 100% POWER, 4 EFFD, THIS IS LEVEL 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

F E

D C

B A

eeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1074
  • 1.6611
  • 1.6236
  • 1. 7 9 9 3
  • 1. 4 5 87
  • 1. 63 2 2 * ' t. 614 0
  • 1. 42 3 4 *

. 1. 9873..*. 1. 3249..*.1. 3632..*. 1 2280..*. 1. 5117..*.1. 3539.*. 1. 3719..*. 1 5.462...*

9

  • 1.6611
  • 1.3955
  • 1.8153
  • 1.6622
  • 1.8202
  • 1.6815
  • 1.6633
  • 1.0667 *

. 1. 3 2 4 9.. *.1.57 7 7..*. 1. 219 7. e

  • e e e. 3 3 6 3.. *.1.

213 6. *.1. 3 2 2 5. *. 1. 3 3 0 6. *.2.

0 6 3 0.. *.

1 4

ee.

e ee.

1 10

  • 1.6236
  • 1.8175
  • 1.6975
  • 1.8539
  • 1.6825
  • 1.6879
  • 1.5679
  • 1.3066 *
  • 1.3632
  • 1.2183
  • 1.3089
  • 1.1994
  • 1.3325
  • 1.3176
  • 1.4177
  • 1.6910
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7993
  • 1.6665
  • 1.8593
  • 1.5208
  • 1.8518
  • 1.6343
  • 1.6258
  • 1.0742
  • 30..*. 1. 1961.*.eee.4617..*. 1. 2008. *. 1. 3684..*. 1 3710
  • 2. 0650 *
  • 1.2280
  • 1.33 1

eeeeeeeeeeeee..

e..

12

  • 1.4507
  • 1.3378
  • 1.6922
  • 1.8582
  • 1.6868
  • 1.7050
  • 1.4309
  • 1
  • 1.5117
  • 1.2075
  • 1.3152.*.1 1968.*. 1. 3290..*. 1.3144
  • 1.561R eeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeeeeeeeeeeeee.

13

  • 1.6322
  • 1.6900
  • 2.6954
  • 1.6418
  • 1.7125 + 1.6033 *

.8814

  • e e e e e e.9..*. 1. 316 0.. *. 1. 310 5
  • 1. 3 615
  • 1. 3 0 8 9
  • 1. 3 9 9 4
  • 2. 5 4 5 5 *
  • 1.353

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.6140
  • 1.6675
  • 1.5733
  • 1.6333
  • 1.4405 *

.9050 *

  • 1. 3 719.. *.1. e. 3 2 81
  • 1. 413 0
  • 1. 3 6 41.. *. 1. 5 517.. *. 2 47 8 5.. *.

e.

eeeeeeeeeeeeeeeeeee 15

  • 1.4234
  • 1.0656
  • 1.3109
  • 1.0796
  • 1. 6858..*. 2.0552..*. M-SUB-Q
    • ee.

...ee.

i I

Catawba 2 Cycle 7 Core Operating Limits Report Page 6 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M.SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 1004 POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 TOP OF CORE, LEVEL 1 = BOTTOM)

(LEVEL 18 m

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1203
  • 1.6911
  • 1.6558
  • 1.8368
  • 1.4876
  • 1.6665
  • 1.6536
  • 1.4587 *

. 1.e.9204

  • 1.2750
  • 1.3081
  • 1.1773
  • 1.4519
  • 1.2979
  • 1.3105
  • 1 4732
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eee.

9

  • 1.6911
  • 1.4191
  • 1.8539
  • 1.6965
  • 1.8678
  • 1.7200
  • 1.7040
  • 1.0892
  • e.1. 2 7 5 0.. *. 1 5191. *.1.

16 8 4. *. 1. 27 9 5.. *. 1.16 0 9. *.1.

2 6 31..*.1.2 6 9 8. *. 1. 9 7 2 2..

  • ee...

10

  • 1.6558 *.1.8560
  • 1.7318
  • 1.8946
  • 1.7222
  • 1.7275
  • 1.6044
  • 1.3366 *
  • 1.3081
  • 1.1671
  • 1.2536
  • 1.1449
  • 1.2638
  • 1.2587
  • 1.3547
  • 1.6166 *'

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 11

  • 1.8368
  • 1.7018
  • 1.9010
  • 1.5540
  • 1.8935
  • 1.6729
  • 1.6665
  • 1.0956 *
3.. *. 1. 27 6 5..*.1 1419. *.1. 3 9 7 5. *.1.

14 61. *. 1. 3 0 4 2.. *. 1. 3 0 4 9. *e e e e. 9 7 8 3

  • 1
  • 1.177

..... ee.

ee**ee eeeeee.

12

  • 1.4876
  • 1.8785
  • 1.7307
  • 1.9010
  • 1.7254
  • 1.7489
  • 1.4641 *
  • 1. 4519..*.1. 15.47..*. 1. 2572..*.1.1425
  • 1.2660
  • 1. 2471..*.1. 4878.*.

e.

. eeeeeeeeeeeeeeeeee 13

  • 1.6665
  • 1.7286
  • 1.7350
  • 1.6804
  • 1.7564
  • 1.6440 *:.8986 *

. 1. 2979..*.1.e.2565.*. 1. 2514

  • 1.2979
  • 1.2414
  • 1.3281.*. 2. 433.9.*.

e...

. eeeeeeeeeeeeeeeeeeeeeeeeeeee 1.6536

  • 1.7082
  • 1.6108
  • 1.6750
  • 1.4748 *

.9232

  • 14
  • e.1. 3105..*. 1 2 67 5 e
  • e e e. 3 4 97
  • 1. 2 9 87
  • 1. 47 7 6
  • 2 3 67 4
  • 1 e

eeeeeeeeeeeeeeeeeeeeeeeee eeeen 15

  • 1.4587
  • 1.0892
  • 1.3409
  • 1.1010
  • 1.4732
  • 1.9740
  • 1.6118 *.1.9693
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee AT 100% POWER, 4 EFPD, THIS IS LEVEL ~7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

F E

D C

B A

....H.........G......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. eee...eeeeeeeeeeeeeeee 8* 1.0956

  • 1.6665
  • 1.6322
  • 1.8164
  • 1.4651
  • 1.6483
  • 1.6386
  • 1.4459
  • e.1. 9 0 3 7.. *. 1. 2 47 9.. *. 1. 2 818. e *e.1.

14 9 4. *.1.4 212. *.1. 2 6 4 0.. *e e e e. 2 7 02

  • 1. 4 219
  • 1 ee eeeeeeeeeeeeee.

9

  • 1.6665
  • 1.3944
  • 1.8336
  • 1.6740
  • 1.8507
  • 1.7007
  • 1.6900
  • 1.07.53
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 2355
  • 1.2325
  • 1.9112 *
  • 1.2479
  • 1.4914
  • 1.1443
  • 1.2563
  • 1.1365
  • 1 eeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6322
  • 1.8357
  • 1.7082
  • 1.8775
  • 1.7029
  • 1.7125
  • 1.5872
  • 1.3216 *
  • 1.2818
  • 1. 1431.*. 1. 2345.*. 1. 1273..*. 1. 2429..*. 1.2305.*. 1. 3221.*. 1 5649..*.

eeeeeeeee..

ee.

eeeeee 11

  • 1.8164
  • 1.6793
  • 1.8839
  • 1.5337
  • 1.8764
  • 1.6558
  • 1.6515
  • 1.0796 *-

1247

  • 1 3826.*.1. 1298 *. **ee 2902..*. 1. 2808.*. 1. 9288.*.

1

  • 1
  • 1.2533
  • 1

... 1494

..eeeeeeeeeee...

1.7061 = 1.1J50 = 1.e460

  • 1 12
  • 1.4651
  • 1.8603
  • 1.7125
  • 1.8828
  • 1.4212
  • 1.1306
  • 1.2360
  • 1.1258
  • 1.2550
  • 1.2322
  • 1.4713
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese l

13

  • 1. 6 4 8 3
  • 1.710 4
  • 1.7211
  • 1. 6 f 3 3
  • 1.7 42 5 a 1.6279 *

.8846

  • 2 2 3 5..*. 1. 2.n 41. e *e e e e. 2 2 6 6. *. 1. 31. 4 4. *. 2. 412 4
  • 1
  • 1.2640
  • 1.2292
  • 1 e.

ee**e

    • eeeeeeeeeeeeeeeee.

14

  • 1.6386
  • 1.6943
  • 1.5936
  • 1.6611
  • 1.4587 *

.9093 *

  • 1. 2702.*.1. 2304.*. 1. 3174
  • 3.4746..*.1. 4606.*.2. 3470..*

ee eeeeeeee i

15

  • 1. 4 4 5 9
  • 1. 07 42
  • 1. 32 59
  • 1. 0 8 4 9

... 4219 *... 1. 9128.*.1. 5604.*. 1. 9199

  • M-SUB-Q 1..

e**ee.

J

1 l

l l

Catawba 2 Cycle 7 Core Operating Limits Report Page 7 of 144 l

Appendix A l

l l

TABLE 1 (CONTINUED)

)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION j

l I

AT 100% POWER.

4 EFPD, THIS IS LEVEL 6 OF 18 l

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) e...H.........G.........F.........E.........D........C.........B.........A......

)

  • 1.3880
  • 8
  • 1.0378
  • 1.5926
  • 1.5572
  • 1.7425
  • 1.3977
  • 1.5840
  • 1.5722 e.1. 9134... 1 2 4 91..*.1.2 8 6 5.. *.1.
1. 4 6 4. *.1 4 2 5 8.. *.1.

2 57 4. *.1.2 6 6 2.. *.1.

416 5.. *e 9

  • 1.5926
  • 1.3259
  • 1.7586
  • 1.5990
  • 1.7768
  • 1.6290
  • 1.6258
  • 1.0260
  • e.1. 2 4 91. * **.1 5 015.. *. 1. 1419. *.1.

2 5 82.. *.1.13 3 3. *. 1. 2 3 2 7.. *. 1. 2 2 5 9. *. 1. 9161. *.

10

  • 1.5572
  • 1.7607
  • 1.6322
  • 1.8036
  • 1.6311
  • 1.6472
  • 1.5208
  • 1.2659
  • e.1. 2865.*. 1. 1401..*.1. 2358..... 1 1198 *... 1. 2408.*.1 2234.*.1. 3186..*. 1. 5613..*.

11

  • 1.7425
  • 1.6044
  • 1.8100
  • 1.4662
  • 1.8025
  • 1.5862
  • 1.5862
  • 1.0292
  • j

. 1. 1464.*. 1. 2544.*. 1. 1164.*.1 3790.*. 1 1214 *.... 1. 2826.*. 1. 2703.*. 1. 9308..*

t 1.8100

  • 1.6343
  • 1.6675
  • 1.3848 i

12

  • 1.3977
  • 1.7875
  • 1.6408
  • eeeeeeeeeeeeeee.48.*. 1. 2337
  • 1.1174
  • 1.2552
  • 1.2256
  • 1.4619
  • 1.4258
  • 1.12 l

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen.

13

  • 1.5840
  • 1.6386
  • 1.6558
  • 1.5947
  • 1.6761
  • 1.5604 *

.8429 *

. 1. 257.4.*. 1 226.5.*.1. 2160.*. 1 2758.*.1. 2200.*.1 3105..*.2. 4063. *.

l 14

  • 1.5722
  • 1.6290
  • 1.5262
  • 1.5958
  • 1.3955 *

.8664

  • l
  • 1. 2662..*.1. 2233.*. 1. 3138..ee. 1 2636.*. 1. 4512..*.2. 3392..*

ee e

l 15

  • 1.3880
  • 1.0260
  • 1.2702
  • 1.0346
    • e 4165..*. 1. 9165.*. 1 5568.*. 1 9222..*. M-SUB-Q 1...

AT 100% POWER, 4 EPPD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) l

....H.........G.........F.........E.........D.........C.........B........A......

1.0025

  • 1.5465
  • 1.5165
  • 1.6997
  • 1.3623
  • 1.5530
  • 1.5433
  • 1.3634
  • 8 *
  • 1.3797 *
  • 1.8906
  • 1.2317
  • 1.2647
  • 1 1246..*. 1. 3989
  • 1.2267
  • 1.2334
          • eseeeeeeeeeeeeeeeeeeeeeen

..eeeeeeeeeeeee**ee eeeeeeeeee.

9* 1.5465

  • 1.2863
  • 1.7147
  • 1.5594
  • 1.7372
  • 1.5958
  • 1.5947
  • 1.0046
  • e.1. 2 317 *.1. 47 9 9. *. 1. 12 0 8.. *. 1. 2 3 4 8 *.... 1. 1051..*. 1. 2015
  • 1e.1942.*.1. 8726.*.

e***

1.5165

  • 1.7168
  • 1.5904
  • 1.7629
  • 1.5947
  • 1.6119
  • 1.4898
  • 1.2402
  • 10 *

.... *

  • 2116. *. 1. 19 4 9.. +. 1. 2 8 5 4.. *.1.

5 2 42.. *.

  • 1 e.1. 2647..*. 1. 1191
  • 1.2120..*.1. 0939

..e**e*ee.

11 + 1.6997

  • 1.5658
  • 1.7693
  • 1.4319
  • 1.7618
  • 1.5530
  • 1.5551
  • 1.0046
  • eee 1246 *.... 1. 2299..*. 1. 0903
  • 1. 3465.*.1. 0945..*. 1. 2487.*. 1. 2352..*ee. 89161....*
  • 1 12
  • 1.3623
  • 1.7489
  • 1.6054
  • 1.7693
  • 1.6001
  • 1.6354
  • 1.35b9
  • 1.1874
  • 1.4220
  • 6.*.1. 2178 *
  • 1.398 1

1.2042

  • 1.090 eeeeee.9.*eee.0980
  • eeeeeeeeeeeeeeeeeeeeen eeeeeeeeeeeeeeeeeee..

13

  • 1.5530
  • 1.6044
  • 1.6204
  • 1.5615
  • 1.6440
  • 1.5305 *

.8225

  • i

. 1. 2267

  • 1 1968..*. 1. 1877.*. 1. 2422..*. 1. 1816..*.1 2689..*. 2.3465.*.

1.5979

  • 1.4962
  • 1.5647
  • 1.3666 *

.8461

  • 14
  • 1.5433 *
  • 1. 2334.*.1*.1919..*. 1. 2809.*. 1. 2289.*. 1. 4113..*. 2. 2800..*.

e.

15

  • 1.3634
  • 1.0046
  • 1.2434
  • 1.0100

3797

  • 1..,8736 *... 1.5199.*. 1.8817..* M-SUB-Q
  • 1 e***e.

i I

r I

l i

l

~

l-I l

l Catawba 2 Cycle 7 Core Operating Limi(s Report Page 8 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 100% POWER, 4 BFPD, THIS IS LEVEL 4 OF 18 s(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F E

D C-B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.9050

  • 1.4073
  • 1.3773
  • 1.5583
  • 1.2445
  • 1.4341
  • 1.4234
  • 1.2574
  • 1 4713.*.1. 2747..*.1. 2835
  • 1 4365.*.
  • 2.0153
  • 1.3009
  • 1.3388
  • 1.1792
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

9

  • 1.4073
  • 1.1674
  • 1.5669
  • 1.4223
  • 1.5990
  • 1.4673
  • 1.4716'*

.9221 *

  • 1. 3009..*.1. 5690.*.1.1779
  • 1.3001.*.1 1518..*. 1. 2533.*eeee.2414
  • 1.9585
  • 1 e.

.ee.

..eeeeeeeeeeeeee...

ee.**eeeeeeeee.

10

  • 1.3773
  • 1.5690
  • 1.4491
  • 1.6172
  • 1.4608
  • 1.4833
  • 1.3687.* 1.1374
  • e.1. 3388.*..1. 1763
  • 1.2774
  • 1.1424
  • 1 2677.e*eee.2450
  • 1.3416
  • 1.5939
  • 1 eeeeeeeeeeeeeeeeeeeeeeee.

e eeeeeeeeeeeeeeeeeeeeeeen 11

  • 1.5583
  • 1.4287
  • 1.6236
  • 1.3088
  • 1.6172
  • 1.4244
  • 1.4298 *

.9178 *

  • 1. 1792..*. 1. 2946.*.1. 1384.*. 1. 4117..*.1 1424.*.1. 3032.*. 1 2854.*.1 9865.*

e.

12

  • 1.2445
  • 1.60.7
  • 1.4705
  • 1.6247
  • 1.4673
  • 1.5048
  • 1.2434 *^

1 e.1 4713..*. 1. 1442.*.1. 2602..*.1. 1382

  • 1. 2680.*eee.2312
  • 1.4829

.ee..

eeeeeeeeeeeeeen l

l 13

  • 1.4341
  • 1.4737
  • 1.4908
  • 1.4319
  • 1.5123
  • 1.4062 *

.7518

  • e.1 2747..*. 1. 2486.*. 1. 2372.*. 1 2970
  • 1.2253
  • 1.3179
  • 2.4519 *

.ee

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.4234
  • 1.4748
  • 1.3741
  • 1.4384
  • 1.2531 *

.7743 *

. 1 2835.*.1 2393..*. 1. 3366.*.1 2782..*.1. 4718..*. 2. 3830..*.

J

/

15

  • 1.2574 *

.9221

  • 1.1417 *-.9221

e e e e e *

  • e e e e e e e e e e e e e e e e e e e e e. 97 6 6.
  • M-SUB-Q 1.4365
  • 1.9603
  • 1.5892
  • 1....

i I

l I

AT 100% POWER, 4 RFPD, THIS IS LEVEL 3 OF 18 i

j (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON)

I i

H G

F E

D C

B A

l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

l 8*

.8107

  • 1.2574
  • 1.2349
  • 1.4084
  • 1.1353 a 1.3216
  • 1.3173
  • 1.1535 *

- 1

.I e.2. 1782.*.1*.4083

  • 1.4445
  • 1.2600
  • 1.5596
  • 1.3359.e*eeee.3401
  • 1. 5.116 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeee.

.een I

9

  • 1.2574
  • 1.0485
  • 1.4062
  • 1.2831
  • 1.4608
  • 1.3516
  • 1.3548 *

.8504 *

. 1. 4 0 8 3.. *.1.6 8 8 9.. *. 1. 2 6 8 5. *.1 3 9 2 3.. *. 1. 2181. *. 1. 313 6. *. 1. 3 02 5. *. 2. e. 0 5 2 9

  • eeeee.

10

  • 1.2349
  • 1.4084
  • 1.3034
  • 1.4641
  • 1.3313
  • 1.3527
  • 1.2574
  • 1.0335 *
  • 1.4445
  • 1.2670
  • 1.3724
  • 1.2181
  • 1.3425
  • 1.3160
  • 1.4105
  • 1.6942
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 11
  • 1.4084
  • 1.2895
  • 1.4705
  • 1.1920
  • 1.4662
  • 1.2991
  • 1.3045 *

.8322 *

  • 1.260c
  • 1.3865 + 1.2136
  • 1.4949
  • 1.2174
  • 1.3768
  • 1.3582
  • 2.1144 *
    • ,e***,*****eseeeeeeeeeeeeeeessesseeeessseseeeeeeeeeeeeeeeeeeeessessese.

12

  • 1.1353
  • 1.4705
  • 1.339"
  • 1.4715
  • 1.3377
  • 1.3720
  • 1.1353 *

. 1 5 5 9 6. *. 1. 2 09 9.. *. 1e. 3 3 51

  • 1. 212 6. *.1.

3 4 01. *.1.3 0 0 2.. *. 1. 5 6 4 8. *.

eeeeeeeeee...

13

  • 1.3216
  • 1.3570
  • 1.3612
  • 1.3066
  • 1.3784
  • 1.2852 *

.6897

  • 1 1

i

  • 1.3359
  • 1.3088
  • 1. 3080
  • 1.3698.*. 1. 2940..*.1.3874..*. 2. 5787..*e l

eeeeeeeeeeeeeeeeee..

..eeeeee..

14

  • 1.3173
  • 1.3580
  • 1.2627
  • 1,3120
  • 1.1449 *

.7101

  • 4
  • 1.340 1

eeeee. 1.*.eee.2997

  • 1.4054
  • 1.3506
  • 1.5529
  • 2. 5037..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1535 *

.8493

  • 1.0378 *

.8365

. 1. 5116

  • 2. 0540..*. 1. 6889.* 2. 1042
  • M-SUB-Q e*e.

.een.

1 p

l i

i l

Catawba 2 Cycle 7 Core Operating Limits Report Page 9 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION 1

AT 100% POWER, 4 EFPD.

THIS IS LEVEL 2 OF 18 l

(LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM) j i

A l

....He e e e e e e. 0......... F...... e. 3. e' e....

.D......... C........ B.. e e.... e e e e e e.

8*

.6501 *

.9800 *

.9703

  • 1.1192 *

.9339

  • 1.1117
  • 1.1203 *-.9436
  • l
  • 2. 6545.*. 1. 7631.*. 1. 7931.*.1 5455.'*.1. 8442..*.1. 5.433..*.1 5317
  • 1.7982
  • e.

... eeeeeeeeeeeeeee 9*

.9800 *

.8354

  • 1.0988
  • 1.0185
  • 1.1995
  • 1.1385
  • 1.1395 *

.7229 *

  • 1.e.7631.*. 2. 0686 8. 1. 5 817 e *e.1.

710 0. *. 1. 4 42 8.. *.1.5157.. *. 1. 5 0 51.. *. 2. 3 5 2 3.. * -

ee ee..

ee.

eeee

.ee 10 *

.9703

  • 1.1010
  • 1.0260
  • 1.1642
  • 1.0903
  • 1.1138
  • 1.0T39 *

.8247 *

~

I

. 1. 7931..*.1 5794

  • 1.6993
  • 1.4900
  • 1.5951
  • 1. 5477..*. 1. 6362
  • 2.0666
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeee.

11

  • 1.1192
  • 1.0239
  • 1.1685 *

.9725

  • 1.1931
  • 1.0710
  • 1.0667 *

.6737

  • 1 e.1 5455.*.1. 7019.*.1. 4849
  • 1.7855.*.1. 4535.*.1. 6220
  • 1.6124
  • 2.5449.*

]

.. eeeeee.e..

e***eeeeeeeeeeeeee**

  • 12 *

.9339

  • 1.2070
  • 1.0967
  • 1.1995
  • 1.0903
  • 1.1224 *

.9361 *

  • 1 8442..*.1. 4337..*. 1. 5857..*.1 4467..*eee.5974
  • 1.5400
  • 1.8451
  • 1 l

e..

..... e eeeeeeeeeeeeeeeeeeeeeeee -

13

  • 1.1117
  • 1.1428
  • 1.1192
  • 1.0764
  • 1.1288
  • 1.0549 *

.5805

  • e.1 5 4 3 3. *.1.510 4. *.1. 5 4 0 0. *.1.613 6. *.1. 5 313. *. 1. 6 412.. *. 2. 97 6 0. *.

14

  • 1.1203
  • 1.1417
  • 1.0581
  • 1.0731 *

.9425 *

.5976 *

'

  • 1. 5317. *.1. 5. 0 2 0. *.1.63 0 0.. *. 1. 6 0 4 0. *.1.

8 310.. *. 2. 8 9 2 5.. *.

l 15 *

.9436 *

.7219 *

.8279 *

.6769

  • 1. 7982..*.2. 3533..*. 2. 0596
  • 2.5313. *. M-sUB-Q e.

..eeeeee i

AT 100% POWER,

& EFPD,'

THIS IS LEVEL 1 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F E

.D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeeeeee.eeeeeeeeeeeeeeeeee 8*

.4155 *

.3181 *-.5858 *

.3791 *

.6030 *

.7561 *..7036 *

'.5430

  • 4.46 3

eeeeeeeeee.5 3146..*eee.9058

  • 3 5.. *.2.7 9 8 6.. *.2.2181.*. 2. 3 9 3 8.
  • e e e. 0 6 4 4 *
  • 4.0651
  • 2 eeeeeeeeee..

es

. e eeeeee l

9*

.3181 *

.5216 *. 3684 *

.6319 *

.4295 *

.7015 *

.7336 *

.4541

  • j e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.37..*.3.

9 312. e * *2 4 09 8.*.2.

2 82. 5.*.3.e. 677 6

  • j
  • 5.3146
  • 3.2538
  • 4.6115
  • 2.69 eeeee.

i 10 *

.5858 *

.3694 *

.6126 *

.3963 *

.6640 *

.7422 *

.6400 *

.2613 *

  • 2.9058
  • 4.6115
  • 2.7786
  • 4.2869
  • 2.5522
  • 2.2682..*eeee.5999
  • 6.3923 *

'2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeen 11 *

.3791 *

.6351 *

.3973 *

.6300 *

.4284 *

.6640 *

.6437 *.4134

  • e.4. 4635.**2.6803
  • 4.2700
  • 2.6922..*.3. 9496.*. 2. 5613
  • 2.6156 *.4.0651 *
        • eeee**eeeeeeeeeee.

..eeeeeeeeme**eeeeeeeese 12 *

.6030 *

.4327

  • 6683 *

.4305 *

.6608 *

.6676 *

.5569 *

  • 2.7986
  • 3.9029
  • 2.5373
  • 3.9353
  • 2.5734
  • 2.4579
  • 3.0368
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l

'13 *

.7561 *

.7047 *

.7454 *

.6672 *

.6908 *

.6201 *

.3599 *

.. 2. 2181.. *. 2. 4 018.. *. 2. 2 5 87.. *. 2. 5 4 9 2.. *.2.

4 4 6 8. *. 2. 7 315 * ** e.4 7 07 4.. *.

14 *. 7036 *

.7347 *

.6512 *

.6469 *

.5612 *. 3695

  • 1 I

. 2. 3938..... 2. 2801..*.2. 5906

  • 2. 6030..*. 3. 0132..*.4 5822..*.

15 *

.5430 *

.4541 * '.2624 4155

. 3. 0 6 4 4.. *. 3. 677 6. *. 6. 3 7 3 5.. *. 4. 0 4 5 5. *. M-SUB-Q q

i t

i i

t h

l I

h I.

(

l l

l Catawba 2 Cycle 7 Core Operating Limits Report.

Page 10 of 144 Appendix A TABLE 1 (CONTINUED)

(

F-SUB-Q & M-SUB-Q VALUES (F-SUS-Q OP KARGIN) - NORMAL OPERATION I

AT 100% POWER, 150 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.4991 *

.4038 *

.6640 *

.4552 *

.6501 *

.7497 *

.6972 *

.5516

  • eeeeeeeeeeeeeeeeeeeeeee.2.7338
  • 1.9015 *.1.6341
  • 1.7479
  • 2.1855
  • 3.0136
  • 1.8859
  • e.2. 2805
  • eeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9*

.4038 *

.6094 *

.4477 *

.6854 *

.4830 *

.7101 *

.7186 *

.4766

  • l
  • 3. 0136.*.2. 0413
  • 2.7853
  • 1.8174
  • 2. 5790..*. 1. 73.45.e*eee.7046
  • 2. 5362..*.

1 e.

eeeeee.eeeeeeeeeeee.eee..

e eeeeee.

[

10 *

.6640 *

.4477 *

.6758 *

.4605 *..6865 *..7358 *

.6576 *

.2967 *

  • eme.859..*. 2. 7853..*.1. 8330
  • 2.6942
  • 1.7979
  • 1.6816
  • 1.8805
  • 4.1286 *
  • 1.8..

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11 *

.4552 *

.6865 *

.4616 *

.6458 *

.4584 *

.6597 *

.6340 *

.4477 *

  • 2. 7338.*.1 8.132..*.2. 6850
  • 1.8611
  • 2.6045
  • 1 8074
  • 1.9147
  • 2.7250 *

.. eeeeeeeeeeeeeeeeeeeee..eeeeeeeeeeeeeeeeeeeeee.

12 *

.6501 *

.4852 *

.6887 *

.4595 *

.6362 *

.6276 *-.5537 *

  • 1. 9015..*. 2. 5664..*.1 7951.*.2. 6003.*. 1. 7510.*. 1. 7814.*.2. 1432..*

I 13 *

.7497 *

.7111 *

.7379 *

.6608 *

.6287 *..5644 *

.3856

  • e.1 6341.*. 1. 7326.*. 1. 6781 8'1. 8033.*. 1. 7774.*.1. 9521.*.3. 00.92..*.

14 *

.6972 *

.7197 *

.6587 *

.6362 * '.5558 *

.3909

  • l eeeeeeeeeeee*e 46.e*e**.8774
  • 1.9110
  • 2.1363
  • 2.9653 *
  • 1.7479
  • 1.70 1

e

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15 *

.5516 *

.4766 *

.2967 *

.4477

  • 2. 1855.*. 2. 5362..*.4 1244.*.2. 7203.*. M-sUB-Q 1

j AT 100% POWER, 150 EFPD, THIS IS LEVEL 17 OF 18

)

(LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON)

H O

F E.

D C

B.

A

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7358

  • 1.0174 *

.9800

  • 1.0871 *

.9328

  • 1.0249
  • 1.0025 *

.8504

  • e 2.0434
  • 1.5345
  • 1.6037.*. 1 4321
  • 1.6567
  • 1.5010
  • 1.5139
  • 1.7639 eeeeeeeeeeeeeeeeeeeeeeee

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.0174 *

.8889

  • 1.0721 *

.9971

  • 1.1010
  • 1.0367
  • 1.0185 *

.6779 *

. 1. 5 3 4 5.. *. 1. 7 5 8 9. *.1.

4 6 4 3 e *e e e e. 57 3 4. *.1.

4 071.. *. 1. 4 9 7 6.. *.1.

5 0 9 2.. *. 2. 214 5.*.

1 e

10 *

.9800

  • 1.0731
  • 1.0121
  • 1.0860
  • 1.0164
  • 1.0228 *

.9618 * '.7786 *

  • 1.6037
  • 1.4632
  • 1.5468
  • 1.4275
  • 1.5311
  • 1.5238
  • 1.6107
  • 1.9747
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

11

  • 1.0871 *

.9992

  • 1.0860 *

.9253

  • 1.0828 *..9735 *

.9436 *'.6490

  • i

. 1. 4321..*.1. 5696..*. 1. 4254..*. 1. 6671..*.1. 4254.*. 1.e.5732

  • 1.6215
  • 2.3556 *

.ee

    • eeeeeeeeeeeeeeeeeeeeen 12 *

.9328

  • 1.1042
  • 1.0196
  • 1.0839 *

.9564 *

.9607 *

.8332 *

. 1. 6567.*. 1. 3989..*. 1. 5270..*. 1. 42.40.*.1 5392..*. 1. 5433..*. 1. 8100.*.

1 I

13

  • 1.0249
  • 1.0399
  • 1.0260 *

.9757 * '.9639 *

.8943 *

.5644

  • e.1. 5 010.. *. 1. 4 9 6 4..
  • e e e. 519 8
  • 1. 5 6 9 4. *. 1. 5 4 0 4. *.1.

6 4 41. *. 2. 6 2 4 9.. *. -

1 eeeeeeeee..

14

  • 1.0025
  • 1.0185 *

.9628 *

.9457.*-

.8365 *

.5741 *

  • 1.5139
  • 1.5000
  • 1.6088
  • 1.6174
  • 1.8043
  • 2.5815
  • eeeeeeeeeeeeeeeeeeeeeeeeeee**ee.. eeeeeeeeeen. eeeeeeee 15 *

.8504 *

.6779 *

.7797 *

.6501

  • 1.7639
  • 2.2170
  • 1.9727
  • 2.3528
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

v

<w-

+

Catawba 2 Cycle 7 Core Operating Limits Report Page 1I of 144

/gppendix A TABLE 1 (CONTINURD)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 100% POWER, 150 EFPD,- THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 e BOTTOM) e...H.........Q.........F.........E.........D........C.....e.3........A......

8 *

.9243

  • 1.2852
  • 1.2203
  • 1.3484
  • 1.1224
  • 1.2445
  • 1.1749
  • 1.0185 *
  • 1.3 1.3992.*.1.5927
  • e 1 8 4 0 9. *.1. 3 3 7 9. *.1 4110 *. e e e. 2 5 2 2
  • 1. 4 8 5 9eeeeeeeeeeeeeeee.410
  • 1 eee e.eeeeee ee eeeeeeee.

9

  • 1.2852 a 1.0935
  • 1.3462
  • 1.2359
  • 1.3452
  • 1.2370
  • 1.2167 *

.7818 *

. 1 3379.*.1 565.1.*.1. 2783.*. 1 3823..*. 1 2583.*. 1. 3713..*.1 3685..*. 2. 0726.*

10

  • 1.2209
  • 1.3473
  • 1.2584
  • 1.3602
  • 1.2349
  • 1.2488
  • 1.1417 *

.9478 *

  • 1 4110.*.1. 2772..*.1 3643.*. 1 2599..*.1. 3858.*.1. 3681..*.1 4866.*. 1. 7630 11
  • 1.3484
  • 1.2381 + 1.3602
  • 1.1267
  • 1.3484
  • 1.1749
  • 1.1428 *

.7765 *.

e.1.., 4. n. 41.. *.1.3 7. 8 6. *. 1. 2 6 07.. *.1.

5 0 4 6. *.1.2 6 3 5.. *.1 4 3 8 6. *. 1. 47 2 4. *. 2. e.15 8 6

  • eeeee.

12

  • 1.1224
  • 1.3495
  • 1.2391
  • 1.3505
  • 1.2017
  • 1.1942 *

.9960 *

. 1 48.59.*.1. 2.522.*. 1. 3811.*.1. 2614.*.1. 3980.*.1 3996... 1. 6770..*

l 13

  • 1.2445
  • 1.2413
  • 1.2531
  • 1.1770
  • 1.1963
  • 1.0935 *

.6587 *

. 1. 3410

  • 1 3667..*. 1. 3636 *... 1. 4356..*. 1 3964.*.1 5197..*.2. 4915.*.
    • ee.

14

  • 1.1749
  • 1.2177
  • 1.1428
  • 1.1460
  • 1.0003 *

.6704 *

.. 1 3992..*. 1. 3667..*. 1. 4838..*. 1. 4692..*.1. 6715..*. 2. 4486.*

i i

15

  • 1.0185 *

.7818 *

.9489 *

.7775

  • 1. 5 9 27.. *.2.07 47..*. 1. 7 615. *. 2. 15 6 3. *e M-SUB-Q i-l AT 100% POWER, 150 EFPD, THIS IS LEVEL 15 OF 18 l

(LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM) l

[

....H.........G.........F.........E........D.........C.........B.........A......

t 8* 1.0367

  • 1.4576
  • 1.3741
  • 1.5155
  • 1.2445
  • 1.3848
  • 1.2852
  • 1.1181
  • e.1. 7 210. *.1. 2 3 3 5. *.1.2 9 5. 4. *. 1. 1514.. *.1.

3 7 91. *.1.2 4 6 0.. *. 1. 3 215.. *. 1. 5 017 *

.eeen 9

  • 1.4576
  • 1.2242
  • 1.5230
  • 1.3869
  • 1.5144
  • 1.3666
  • 1.3441 *

.8472 *

  • 1. 2335.*.1. 4509.*.1.1701
  • 1.2741.*. 1 1577..*. 1 2819.*.1. 2787..*. 1. 9676
  • e.

..... eeeeeeeeeeee eeeeee 10

  • 1.3741
  • 1.5240
  • 1.4137
  • 1.5347
  • 1.3794
  • 1.3944
  • 1.2541
  • 1.0442 *

. 1 2954.*. 1. 1694.*.1. 2641.*.1. 1685.*. 1. 2961.*.1. 2725.*. 1. 4003..*.1. 6498.*.

)

11

  • 1.5155
  • 1.3891
  • 1.5347
  • 1.2552
  • 1.5165
  • 1.3034
  • 1.2659 *

.8493

  • 1 i

. 1 151.4.*. 1 2710..*. 1 1690.*.1. 4128.*. 1 1807..*.1. 3643.*. 1. 3956..*. 2. 0621.*.

12

  • 1.2445
  • 1.5197
  • 1.3837
  • 1.5107
  • 1.3366
  • 1.3334
  • 1.0956
  • eeeeeeeeeeeeeeeee 6063
  • e.1. 3 7 91 *. 1. 1514. *. 1. 2 9 2 3. *. 1. 17 87.. *.1. e. 3 27 4
  • 1.3239 *1 eeeeee 13
  • 1.3848
  • 1.3709
  • 1.3987
  • 1.3066
  • 1.3366
  • 1.2092 *

.7165

  • ene 2460
  • 1. 2780.*. 1. 2679
  • 1.3613
  • 1. 3206.*. 1. 4542.*. 2. 4074.*.
  • 1

..ee eeeeeeeeeeeeeeee 14

  • 1.2852
  • 1.3462
  • 1.2563
  • 1.2691
  • 1.0999 *

.7294 *

  • 1.3215
  • 1.2772
  • 1.3984
  • 1.3929
  • 1.6010
  • 2.3650
  • eeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.e I

15

  • 1.1181 *

.8461

  • 1.0453 *

.8514

. 1 5017..*. 1. 9695.*.1. 6485..*. 2. 0580..*. M.SUB-Q l

l l

i i

Catawba 2 Cycle 7 Core Operating Limits Report Page 12 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-8UB-Q OP MARGIN) - NORMAL OPERATION AT 100% POWER, 150 EFPD, THIS IS LNVEL 14 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8
  • 1.0764 *. 1.5251
  • 1.4309
  • 1.5808 *.*. 2841
  • 1.4351
  • 1.3195
  • 1.1438 *
  • 1.7221
  • 1.2243
  • 1.2859
  • 1.1469
  • 1.3792
  • 1.2488
  • 1.3385
  • 1.5261
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5251
  • 1.2702
  • 1.5915
  • 1.4405
  • 1.5787
  • 1.4084
  • 1.3859 *

.8611 *

  • 1.2243.*.1 4401.*. 1 1575.*.1. 2712
  • 1.1531
  • 1.2874
  • 1.2866
  • 1.9999
  • eeeeee...

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.-

10

  • 1.4309
  • 1.5926
  • 1.4673
  • 1.6011
  • 1.4298 *.1.4469
  • 1.2873
  • 1.0699
  • e.1. 2. 8 5 9. *.1.15 6 9. *.1 2 57 7
  • 1.15 8 8. *.1 2. 9 4 8. *.1 2 6 67. e.*.1.

4 0 9 6.

  • e e e. 6 67 5
  • 1

... eeeeee e.. eeeeeee....

eeeee.

'11

  • 1.5808
  • 1.4416
  • 1.6001
  • 1.2981
  • 1.5776
  • 1.3441
  • 1.3034 *

.8654 *

  • 1 1469.*. 1. 2690.*. 1. 1582..*.1. 4142.*.1 1863.*. 1. 3848.*.1. 4167..*.2. 0959.*.

ene 12

  • 1.2841
  • 1.5829
  • 1.4341
  • 1.5008
  • 1.3784
  • 1.3773
  • 1.1224 *
  • 1.3792
  • 1.1475
  • 1.2906
  • 1.1843
  • 1.3536
  • 1.3489
  • 1.6462
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4351
  • 1.4126
  • 1.4512
  • 1.3473
  • 1.3805
  • 1.2413 *

.7283 *

  • 1.2488
  • 1.2827
  • 1.262 1

eeeeeeeeeeeeeeeeeeeeeeeee.1.*.1.3812e*eeee.3455

  • 1.4948
  • 2.4788'*'

. eeee.

eeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.3195
  • 1.3880
  • 1.2895
  • 1.3066
  • 1.1267 *-.7411 *
  • 1.3385
  • 1.2850
  • 1.4068
  • 1.4138
  • 1.6399
  • 2.4361
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1438 *.8611
  • 1.0710 *

.8675

  • 1.9999
  • 1.6662
  • 2.0938... M-8UB-Q eeeeeeeeeeeeeeeeeeeeeeeeee AT 100% POWER, -150 BFPD, THIS IS LEVEL 13 OF 18 (LIVEL 18 = TOP OF CORE, LEVEL 1 = 30TTOM)

H 0

.F E

D C-B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1353
  • 1.6172
  • 1.5155
  • 1.6761
  • 1.3537
  • 1.5144
  • 1.3848
  • 1.2006
  • e.1. 6 8 3 0
  • 1. 2 013 *.1.2 617.. *.1 1311. *.1 3 5 9 5. *.123 6 3. *.1. 3 3 3 5.. *.152.19. *..

eeeeeeeeeeeee..

9

  • 1.6172
  • 1.3430
  • 1.6858
  • 1.5230
  • 1.6708.* 1.4833
  • 1.4598 *

.8996 *

  • 1. 2 013.. *. 1. 4 07 7.. *.1.

13 47. e

  • e e e. 2 514
  • 1. e.13 7 7. e t 1. 2 714
  • 1. 27 4 3
  • 1. 9 9 03.. *.

1 e

eeeeeee eeeeeeeeeeeeeeeeeee....

10

  • 1.5155
  • 1.6879
  • 1.5508
  • 1.6943
  • 1.5101
  • 1.5283
  • 1.3516
  • 1.1213 *
  • 1.2617..*.1. 1335.* 1.2349
  • 1.1353..*.1. 2699..*..1. 2435.*.1. 3930
  • 1. 6539.*.

e**ee.

.... e eeeeeeeeeee eeeeee.

11

  • 1.6761 *.1.5251
  • 1.6933
  • 1.3687
  • 1.6675
  • 1.4148
  • 1.3720 *

.9039 *

  • 1.1311
  • 1.2500
  • 1.13 1

e e e e e e e e e e e e e e e e e e e e e e e. 47. e *e e e e. 3 8 51. *. 1. 16 3 4. *.1.

3 6 67..*. 1 3 9 5 9....

2. 0826..*.

a e...

12

  • 1.3537
  • 1.6761
  • 1.5144
  • 1.6708 8 1.4501
  • 1.4512 *-1.1760 *-

e.1 3 5 9 5. *. 1. e.1317.. *. 1. 2 6 5 4. *. 1. 16 0 9. *.1.

3 4 4 7. *.1 3 3 8 8. *. 1 6 3 81.

  • 13
  • 1.5144
  • 1.4876
  • 1.5337
  • 1.4180
  • 1.4555
  • 1.3023 *

.7604 *

  • 1.2363
  • 1.2676
  • 1.2392
  • 1.3638
  • 1.3355
  • 1.4937
  • 2.4743
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.384S
  • 1.4619
  • 1.3537
  • 1.3752
  • 1.1002 *

.7743 *

  • 1.3335
  • 1.2728
  • 1.3903
  • e e e e e e e e e e e e e e e e e e e e e e e e e e e. 1 3 9 2 3.*.1. 6 3 22..*.2.43 03.*.

15

  • 1.2006 *

.8996

  • 1.1224 *

.9050

  • 1.5219
  • 1.9921
  • 1.6527
  • 2.0786
  • N-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

Catawha 2 Cycle 7 Core Operating Limits Report Page 13 of 144 Appendix A l

I TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALU38 (F+SUB-Q OP KARGIN) -. NORMAL OPERATION i

AT 100% POWER, 150 BFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D" C

B A

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8* 1.1513

  • 1.6504
  • 1.5422
  • 1.7104
  • 1.3730
  • 1.5401
  • 1.4019
  • 1.2134
  • 1.7376
  • 1.2190
  • 1.2932
  • 1.1628
  • 1.4072
  • 1.2749
  • 1.3813
  • 1.5005
  • eneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

9

  • 1.6504
  • 1.3645
  • 1.7200
  • 1.5487
  • 1.7029
  • 1.5037
  • 1.4823 *

.9061

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 1679
  • 1.3088
  • 1.3135
  • 2.0756
  • 1.2190
  • 1.4406.* 1.1598
  • 1.2856
  • 1..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.5422
  • 1.7222
  • 1.5765
  • 1.7265
  • 1.5337
  • 1.5551
  • 1.3666
  • 1.1310
  • 1.2932
  • 1.1591
  • 1.2668
  • 1.1604
  • 1
  • 1.4324
  • 1.7008
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 2994
  • 1.2727

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 11

  • 1.7104
  • 1.5497
  • 1.7265
  • 1.3891
  • 1.6975
  • 1.4330
  • 1.3912
  • 49042 *
  • 1.1628
  • 1.2848
  • 1.1598
  • 1.4166
  • 1.1864
  • 1.4046
  • 1.4258
  • 2.1469
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeee l

12

  • 1.3730
  • 1.7002
  • 1.5390
  • 1.7018
  • 1.4683
  • 1.4716
  • 1.1867
  • 1.4072
  • 1.1629
  • 1.2948
  • 1.1838
  • 1.3766
  • 1.3662
  • 1.6863 *-

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.5401
  • 1.5080
  • 1.5604
  • 1.4373 *'1.4758
  • 1.3163 *

.1647

  • s
  • 1.2749
  • 1.3049
  • 1.2675
  • 1.4009
  • 1.3622
  • 1.5261
  • 2.5464
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.4019
  • 1.4844
  • 1.3698
  • 1.3944
  • l'.1910 *

.7786

  • e 1.3813
  • 1.3120
  • 1.4305
  • 1.4230
  • 1.6792
  • 2.5032
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2134 *

.9061

  • 1.1331 *

.9104

  • 1.5805
  • 2.0776
  • 1.7074
  • 2.1427
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen i

AT 100% POWER, 150 EFPD, THIS IS LEVEL 11 OF 18

(

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D

. C

-B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8

  • 1.1481
  • 1.6590
  • 1.5465
  • 1.7211
  • 1.3730
  • 1.5455
  • 1.4019
  • 1.2102
  • l

. 1. 8235.*. 1 2701.*.1. 3567

  • 1.2173
  • 1.4992
  • 1.3391
  • 1.4560
  • 1. 6676.*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

j 9

  • 1.6590
  • 1.3655
  • 1.7307
  • 1.5519
  • 1.7115
  • 1.5037
  • 1.4855 *

.9007 *

.)

  • 1. 2701..*. 1. 5249..*. 1. 2119..*. 1. 3500
  • 1.2201
  • 1.3748
  • 1.3783
  • 2. 2184.*.

1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 10

  • 1.5465
  • 1.7318
  • 1.5787
  • 1.7350
  • 1.5358
  • 1.5604
  • 1.3645
  • 1.1267 *
  • 1 3 5 6 7.. *. 1. 210 6. *. 1 3 2 8 5. *.1.

2 0 9 2.. *. 1. 3 5 9 3. *.1.

3 2 9 3.. *. 1. 5 0 4 5.. *. e e e.7 9 6 0

  • 1 eeeeen l

[

11

  • 1.7211
  • 1.5530
  • 1.7350
  • 1.3902
  • 1.7050
  • 1.4319
  • 1.3912 *

.9007 *

  • 1.2173
  • 1.348
  • 2.2558
  • eeeeeeeeee***ee.3.
  • 1.2099.*.1e.4930
  • 1.2297
  • 1.4560
  • 1.4839 t

e******ee e*e****ee*****eae***eeeeeeeeee****eseessee l.

12

  • 1.3730
  • 1.7168
  • 1.5412
  • 1.7082
  • 1.4662
  • 1.4737
  • 1.1813
  • 1
  • 1.4992
  • 1.2160
  • 1.3551
  • 1.2270
  • 1.4329
  • 1.4188
  • 1.7553
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.5455
  • 1.5090
  • 1.5669
  • 1.4362
  • 1.4769
  • 1.3130 *

.7583

  • e.1. 3 3 91.. *. 1. 3 7 0 4. *. 1. e. 3 2 4 4.., *. 1. 4 5 21. *. 1. 414 2. *. 1. 5 9 2 9.. *. 2. 6 9 2 6. * '

en.

14

  • 1.4019
  • 1.4865
  • 1.3666
  • 1.3944
  • 1.1856 *:.7722
  • e.1. 4560..*.eee.3765
  • 1.5024
  • 1.4808
  • 1.7497
  • J.6460
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2102 *

.9007

  • 1.1278 *

.9029

  • 1.6676
  • 2.2184
  • 1.7945
  • 2.2511
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee I

1 l

r W

l-i.

l

Catawha 2 Cycle 7 Core Operating Limits Report Page 14 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q 8 N-SUB-Q VALUES (F-SUB-Q OP NJh IN) - NORMAL OPERATION AT 100% POWER, 150 EFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H 0

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8

  • 1.1695
  • 1.7007
  • 1.5840
  • 1.7661
  • 1.4019
  • 1.5819
  • 1.4330
  • 1.2359
  • e.1 919 9..*. 1. 3 214. *.1.415 5...*.1.

2 6 6 6

  • 1. 5 8 2 2
  • 1. 3 9 6 4
  • 1. 516 9
  • 1.7 3 3 0.*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.7007
  • 1.3944
  • 1.7757
  • 1.5883
  • 1.7554
  • 1.5300
  • 1.5208 *

.9168 *

  • 1. 3214.*. 1. 6069.*.1. 2593..*.1.4082
  • 1. 2674.*. 1 4324.*. 1. 4333.*e. 3321..*

2 e.

... eeeeeeeee

.... e 10

  • 1.5840
  • 1.7768
  • 1.6161
  • 1.7789
  • 1.5712
  • 1.6001
  • 1.3934
  • 1.1481 *.

e.1. 4155 *. e e e e e e. 2 5 8. 5. *e e. 3 8. 57. *. 1. 2 5 5 6

  • 1. 415 5.- *.1. e. 3 8 0 4. *. 1. 5 6 47.. *.1.

8 6 6 5

  • 1 1

eeeeeeee**e..

e..

eeeeee 1.7661

  • 1.5904
  • 1.7789
  • 1.4212
  • 1.7479
  • 1.4630
  • 1.4223 *-.9146
  • 11
  • 1.2666
  • 1.4064
  • 1.2556
  • 1.5684
  • 1.2733
  • 1.5081.* 1.5348
  • 2.3427
  • eeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.s019
  • 1.7618
  • 1.5765
  • 1.7511
  • 1.4973
  • 1.5080
  • 1.2038
  • e.1. 5122
  • 1.2629
  • 1.4109
  • 1.2703
  • 1.4793
  • 1.4554
  • 1.8104
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

1.5433

  • 1.6065
  • 1.4673
  • 1.5123
  • 1.3398 *

.7700

  • 13
  • 1.F819 *
  • 1.3954 *-1.4276
  • 1.3751
  • 1.5039
  • 1.4515
  • 1.6343
  • 2.7916
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.4330
  • 1.5230
  • 1.3955
  • 1.4255
  • 1.2001 *

.7840

  • 1 5.169.*.1. 4314.*.1. 5624.*. 1. 5315..*. 1. 8029.*. 2. 7420.*.

15

  • 1.2359 *

.9168

  • 1.1492 *

.9168

  • 1.7330
  • 2.3321
  • 1.8649
  • 2.3402
  • N-SUS-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee AT 100% POWER, 150 BFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) l H

0

.F E

D C-B A:

    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8
  • 1.1460
  • 1.6804
  • 1.5626
  • 1.7500
  • 1.3784
  • 1.5637
  • 1.4126
  • 1.2167 *

. 1. 9 2 7 2.. *.1.3 217.. *. 1. 42 51. *.1.27 3 5.. *. 1. 6 0 8 2.. *. 1 4 2 0 5. *. 1. 5 67 4.

  • e e e. 8112
  • 1 eeeeee i

9

  • 1.6804
  • 1.3709
  • 1.7597
  • 1.5669
  • 1.7393
  • 1.5165
  • 1.5026 *

.9996 *

  • 1.3217
  • 1.6178
  • 1.2683
  • 1.42 1

1.4766

  • 2.4477
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.23.e*eeee.2825
  • 1.4666
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.5626
  • 1.7607
  • 1.5926
  • 1.7618
  • 1.5497
  • 1.5829
  • 1.3709
  • 1.1288 *
  • 1. 4251.*. 1. 2675..*. 1. 3994.*. 1. 2668
  • 1. 4393.*. 1. 4075.*.1.e.6190
  • 1. 9551.*'

)

e ee.

eeeeee.

11

  • 1.7500
  • 1.5679
  • 1.7618
  • 1.3987 *.1.7297
  • 1.4394
  • 1.4030 *

.8964

  • i
  • 1. 2735.*.1. 4214
  • 1.2668
  • 1.5916.*. 1. 2909..*.1. 5495..*. 1. 5858..*. 2. 4644..*.

.e******eeeeeeeee

.e i

12

  • 1.3784
  • 1.7457
  • 1.5551
  • 1.7339
  • 1.4726
  • 1.4876 8 1.1824.*
  • 1. 6 0 8 2.. *. 1. 2 7 87.. *.1.

4 3 4 6. *. e..' 2 87 9.. *. 1. 518 0.. *. 1 5 0 3 3.. *. 1. 8 8 2 0..

  • l.

13

  • 1.5637
  • 1.5219
  • 1.5894
  • 1.4448
  • 1.4930
  • 1.3184 *

.7529 *

  • 1.4?05
  • 1.4627
  • 1.4021
  • 1.5451
  • 1.4991
  • 1.6937
  • 2e.9512
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeen 14

  • 1.4126
  • 1.5048
  • 1.3730
  • 1.4062
  • 1.1877 *

.7668 *

  • 1.5674
  • 1.4756
  • 1.6166
  • 1.5823
  • 1.8755
  • 2.8960.*:

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15

  • 1.2167 *

.8996

  • 1.1299 *

.8986

  • F-8UB-Q eeeeee.... 2. 4477..*.1. 9533
  • 2.4588..*. N-SUB-Q
  • 1.8112
  • eeeeeeeee.

u, A.

--,s a

w Catawha 2 Cycle 7 Core Operating Limits Report Page 13 of 144 Appendix A TABLE 1 (CONTINUED)

NORMAL OPERATION F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN)

AT 100% PONER, 150 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 s BOTTOM)

H O

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1663
  • 1.7190
  • 1.5'979
  • 1.7929
  • 1.4073
  • 1.6001
  • 1.4469
  • 1.2466
  • e.1. 8 4 3 6.. *.1.

2 5 6 5. *. 1 3 5 47.. *. 1. 2 0 81. *.1.

5 3 3 0. *.1.3 4 9 7.. *.1.

4 8 9 8. *.1.7107.. *e 9

  • 1.7190
  • 1.3987
  • 1.8025
  • 1.6022
  • 1.7832
  • 1.5519
  • 1.5412
  • 9189
  • 1.2..... 1 5429.*.1.2021
  • 1.3513
  • 1.2156 *.....

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.2. 3174..*.

1.3931

  • 1.4003 *
      • ee.565
  • 10
  • 1.5979
  • 1.8046
  • 1.6279
  • 1.8046
  • 1.5851
  • 1.6236
  • 1.4019
  • 1.1545 *
  • 1.3547
  • 1.2014
  • 1.3306
  • 1.2006
  • 1.3667
  • 1.3330
  • 1.5385
  • 1.8503
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7929
  • 1.6033
  • 1.8046
  • 1.4287
  • 1.7714
  • 1.4726
  • 1.4373
  • 9146
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.2. 3412..*.

1.2081

  • 1.3505
  • 1.2008
  • 1.5138
  • 1.2225
  • 1.4696
  • 1.5022
  • 12
  • 1.4073
  • 1.7896
  • 1.5915
  • 1.7757
  • 1.5048
  • 1.5251
  • 1.2092 *
  • 1.5330
  • 1.2115
  • 1.3615
  • 1.2197...*.1. 4393..*. 1. 4195..*.1. 7843..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.6001
  • 1.5572
  • 1.6301
  • 1.4769
  • 1.5305
  • 1.3505 *

.7679

  • 1.3497
  • 1.3886
  • 1.3281
  • 1.4656
  • 1.4158
  • 1.6022
  • 2.7987
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.4469
  • 1.5422
  • 1.4052
  • 1.4405
  • 1.2145 *

.7829 *

  • 1.4898
  • 1.3984
  • 1.5352
  • 1.4991
  • 1.7770
  • 2.7490
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.2466 *

.9189

  • 1.1556
  • 9157
  • F-SUB+Q
  • 1.7107
  • 2.3 eeeeeeeeeeeee.174
  • 1.0483
  • 2.3380
  • M-SUB-Q
    • eeeeeeeeeeeeeeeeeeee.

AT 100% POWER, 150 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BCrFTOM)

H O

F D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeee....E...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1556
  • 1.7157
  • 1.5936
  • 1.7939
  • 1.4019
  • 1.6001
  • 1.4459
  • 1.2477
  • e.1. 8112.. *. 1 2 2 0 0. *. 1. 315 0..
  • e e e.16 9 2.. *. 1. 4 8 3 2.. *. 1. 2 9 7 7.. *.1.

42 4 9.. *.1.6 3 4 2.. *.

1 e

eee 9

  • 1.7157
  • 1.3902
  • 1.8036
  • 1.5979
  • 1.7843
  • 1.5508
  • 1.5433
  • 9168 *
  • 1. 2200..*. 1. 5017..*.1. 1643..*. 1. 3112..*.1. 1749..*. 1 3423..*. 1. 3394
  • 2. 2200.*.

eeeeee.

10

  • 1.5936
  • 1.8046
  • 1.6236
  • 1.8057
  • 1.5819
  • 1.6247
  • 1.4009
  • 1.1535
  • 1.315..0. *.1.16 3 7.. *e e e e. 2 9 3 2
  • 1.16 3 7.. *. 1. 3 2 4 3.
  • e e e. 2 8 5 2
  • 1. 47 61
  • 1. 7 6 7 2
  • 1 1

eeeeeeeeee.

.. e eeeeeeeeeeeeeeeeeeeeeee*

eeeeee.

11

  • 1.7939
  • 1.6001
  • 1.8046
  • 1.4244
  • 1.7725
  • 1.4705
  • 1.4384
  • 9104 *
  • 1.1692
  • 1.3104
  • 1.1638
  • 1.4723
  • 1.1856
  • 1.4251
  • 1.4441
  • 2.2418
  • eeeeeeeeeessaseassaaessaaneessee***eeeeeeeeeeeeeaneseeeeeeeeessaaneaeases 12
  • 1.4019
  • 1.7907
  • 1.5883
  • 1.7779
  • 1.5015
  • 1.5272
  • 1.2081 *

. 1. 4832..*. 1. 1706.*. 1. 3194..*. 1. 1826

  • 1.4066
  • 1.3800
  • 1.7223
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6001
  • 1.5562
  • 1.6322
  • 1.4758
  • 1.5315
  • 1.3505 *

.7647 *

  • 1. 2 9 7 7.. *..1.

3 3 8 2.. *. 1. 27 9 9.. *. 1. 4 211.. *. 1. 3 7 6 2.. *. 1. 5 57 8.. *. 2. 7 0 2 6. *.

14

  • 1.4459
  • 1.5455
  • 1.4041
  • 1.4416
  • 1.2134 *

.7786

  • 1.7154
  • 2.6554 *

. 1. 4249

  • 1.3384
  • 1. 4741
  • 1.4412 *
    • ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.2477 *

.9168

  • 1.1556 *-.9125
  • F-SUB-Q e.1. e. 6 3 4 2. *. 2. 2 2 0 0. e *e.1.

7 6 5 8.. *. 2. 2 3 8 9..

  • M-SUB-Q w

x

Catawha 2 Cycle 7 Core Operating Limits Report Page 16 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 100% POWER, 150 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 TCP OF CORE, LEVEL 1 = BOTTOM)

E D

C B

A e...H.........G........Feeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8

  • 1.1181 e 1.6729
  • 1.5519
  • 1.7532
  • 1.3645
  • 1.5647
  • 1.4148
  • 1.2220 *

. 1. 7817...*.1. 1967..*.1. 2919.. 1. 1447...*.1. 4584 *.. 1. 2704.*.1 3943.*. 1. 5977..*.

9

  • 1.6729
  • 1.3505
  • 1.7629
  • 1.5572
  • 1.7457
  • 1.5144
  • 1.5123 *

.8943

  • ee. 19.67. *eee.4798
  • 1.1393
  • 1.2878
  • 1.1484
  • 1.3142
  • 1.3080
  • 2.1797
  • 1 1

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.5519
  • 1.7650
  • 1.5819
  • 1.7 6 61
  • 1. 5 4 4 4
  • 1. 5 915 + 1. 3 6 87
  • 1.127 8 * '
  • 1.2919
  • 1.1387
  • 1.2697..*. 1. 1371
  • 1.2973
  • 1.2552
  • 1.4443
  • 1.7305
  • eeeeeeeeeeeeeeeeeeeeaeeee

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.7532
  • 1.5583
  • 1.7661
  • 1.3880
  • 1.7350
  • 1.4362
  • 1.4084 *

.8879 *

  • 1.1447
  • 1.2871 8 1.1375
  • 1.4434
  • 1.1565
  • 1.3914
  • 1.4019
  • 2.2002
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.3645
  • 1.7532
  • 1.5497
  • 1.7404
  • 1.4662
  • 1.4951
  • 1.1802 *
  • 1.4584
  • 1.1441
  • 1.2926
  • 1.1536
  • 1.3718.* 1.3400
  • 1.6798
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee I

13

  • 1.5647
  • 1.5197
  • 1.5979
  • 1.4416
  • 1.5005
  • 1.3216 *

.7433 *

. 1. 2704.*. 1. 3100

  • 1. 2501.*. 1. 3876.*.1 3359.*.1. 5121..*. 2. 6.481.*

ee.

e***ee.

14

  • 1.4148
  • 1.5144
  • 1.3720
  • 1.4126
  • 1.1856 *

.7572 *.

  • 1.3943
  • 1.3070
  • 1.4424
  • 1.4052
  • 1. 6720
  • 2. 5996..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesee 15

  • 1.2220 *

.8943

  • 1.1299 *

.8900

. 1. 5977

  • 2.1797..*eee.7277
  • 2.1957..* M-SUB-Q

. eeeeeeeee eeeeeeeeee..

AT 1004 POWER, 150 EFPD, THIS IS LEVEL 5 0F 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

H Q

F E

D C

.B A

eeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8* 1.1096

  • 1.6686
  • 1.5497
  • 1.7532
  • 1.3645
  • 1.5690
  • 1.4244
  • 1.2327
  • e.1. 710 0. *. 1. 14 5 0.' *.1.2 3 4 5. *. 1 0 9 2 5. *. 1. 3 919.. *.1.

2 0 9 2.. *. 1. 3 219.. *.1.

513 4.

  • 9
  • 1.6686
  • 1.3452
  • 1.7639
  • 1.5562
  • 1.7500
  • 1.5208
  • 1.5230 *

.8996 *

  • 1 1450..*. 1. 4165..* 1. 0865.*.1. 2291.e. 1. 0 9 2 9. *.1. 2 4 8 9.. *.1.

2 3 9 8.. *. 2. 07 0 4.. *.

e..

10

  • 1.5497
  • 1.7661
  • 1.5797
  • 1.7682
  • 1.5465
  • 1.5979
  • 1.3773
  • 1.1353
  • e.1. 23.45..*.1 0856.*.eee.2121
  • 1.0829
  • 1.2357
  • 1.1921
  • 1.3705
  • 1.6422
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7532
  • 1.5583
  • 1.7682
  • 1.3880
  • 1.7404
  • 1.4426
  • 1.4180 *

.8911 *

  • 1.0925
  • 1.2282
  • 1.0832
  • 1. 3748.*.1 0990.*. 1. 3211.*.-1 3347..*.2. 0938.*.

eee**

eeeeeeeeeeeeeeeeeeeeee.

12

  • 1.3645 8 1.7564
  • 1.5530
  • 1.7457
  • 1.4716
  • 1.5056
  • 1.1877 *
  • 1.9919
  • 1.0891
  • 1.2308
  • 1.0962
  • 1.2999
  • 1.2667
  • 1.5910
  • e e*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13

  • 1.5690
  • 1.5262
  • 1.6054
  • 1.4469
  • 1.5112
  • 1.3313 *

.7454 *

. 1. 2092..*.1. 2443..*.1. 1874

  • 1.3165..*. 1. 2625.*. 1 4285..*. 2. 5191..*.

..eeeeee 14

  • 1.4244
  • 1.5251
  • 1.3794
  • 1.4223
  • 1.1931 *

.7604

  • e.1. 3 219..
  • 1. 2 3 8 4. *. 1. 3 6 8 2..*. 1. 3 314.. *.1.

5 8 4 4.*2. 4711.. *

  • ee 15
  • 1.2327 *

.8996

  • 1.1374 *

.893 2

  • 1.5134
  • 2.0704
  • 1.6401
  • 2.0898
  • N-SUB-C l

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

1 l

Catawha 2 Cycle 7 Core Operating Limits Report Page 17 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M.8UB-Q VALUES (F-sUB-Q OP MARGIN) - NORMAL OPERATION AT 100% POWER, 150 EFPD, 'THIS IS LEVEL 4 OF 18 l

(LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

.... H...... e e e e e e e e e e e e e e e e e e e e e......... D......... C......... B......... A..... e O

F E

8

  • 1.0367
  • 1.5701
  • 1.4587
  • 1.6558
  • 1.2884
  • 1.4898
  • 1.3602
  • 1.1781 *
  • 1.7505
  • 1.1633
  • 1.2554
  • 1.1065
  • 1.4102
  • 1.2186
  • 1.3255
  • 1.5158
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.5701
  • 1.2638
  • 1.6675
  • 1.4683
  • 1.6590
  • 1.4448
  • 1.4533 *

.8579

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.56.9.*eeee.2432
  • 2.0810 *
  • 1.1633
  • 1.4428
  • 1.0992
  • 1.2470
  • 1.1026
  • 1.2 1

eeeeeeeeeeeeeee 10

  • 1.4587
  • 1.6697
  • 1.4898
  • 1.6740
  • 1.4619
  • 1.5187 * ~1.3109
  • 1.0806 *
  • 1.3764 *-1.6509 *
  • 1.2554
  • 1.0983
  • 1.2297
  • 1.0933
  • 1.2491 *=1.1993 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.6558
  • 1.4694
  • 1.6740
  • 1.3120
  • 1.6515
  • 1.3(98
  • 1.3505 *

.8461

  • e.1. 10 6 5.. *.1.2. 4 5 5. *.1.0 9 3 3.. *.1.

3 8 9 9 1.1064

  • 1.3....280.*.1 3.378.*.2.1102..*

...eeeeeeeeeeee.

ee...

12

  • 1.2884
  • 1.6654
  • 1.4683
  • 1.6558
  • 1.3966
  • 1.4351
  • 1.1320 *
  • 1.4102
  • 1.0987
  • 1.2436
  • 1.1031
  • 1.3045
  • 1.2660
  • 1.5933
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4898
  • 1.4501
  • 1.5251
  • 1.3741
  • 1.4394
  • 1.2702 *

.7079 *

  • 1.4252
  • 2.5310
  • j

. 1 2186 *... 1 2520

  • 1.1940
  • 1.3234
  • 1.2616 i~

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.3602
  • 1.4544
  • 1.3141
  • 1.3548
  • 1.1374 *

.7219 *

..eeeeeeeeeeeeeeeeeeee.1. 3345

  • 1.5855
  • 2.4817
  • e.1. 3255
  • 1.2418
  • 1.3738 *

..eeeeeeeeeeeeeeeeeeeee.

15

  • 1.1781 *

.8579 + 1.0828 *

.8482

  • e 515 8.. *. 2. 0 0 0 4.*.
1. e 6 4 8 4
  • 2.10 61.*.M-sUB-Q
  • 1..

eeeeeeeeee..

r AT 100% POWER, 150 EFPD, THIS IS LEVEL. 3 OF 18 l

(LEVEL 18 = TOP OF CORR. LEVEL 1 m BOTTOM) l j

.... H......... O......... F......... B......... D......... C.. e e e e e e e e e e e e e... A......

B 8*

.9618

  • 1.4576
  • 1.3570
  • 1.5433
  • 1.2145
  • 1.4084
  • 1.3013
  • 1.1245
  • tl'
  • 1.8179
  • 1.2091
  • 1.2997.*.1. 1403..*.1. 4419..*. 1. 3431...*.1 3350.*. 1 5316
  • e eeeeeeeeeeeeeeeeeeeeeeee.

. eeeeee 9

  • 1.4576
  • 1.1792
  • 1.5540
  • 1.3709 * *.5530
  • 1.3709
  • 1.3827 *

.8225 *

(

  • 1.2091
  • eeeeeeeeee.1. 4906 *. e e.1.

13 7 2.. *. 1. 2 8 6 8. *. 1. 13 4 4. *. 1. 2 7 57.. *.1.

2 5 8 6. *. 2. 0 9 5 4.

  • e 10
  • 1.3570
  • 1.5551
  • 1.3902
  • 1.5647
  • 1.3730
  • 1.4330
  • 1.2477
  • 1.0239
  • e.1. 2 9 9 7.. *.1.

13 6 2.. *.1.

2 6 0 9.. *. 1. 12 7 5.. *. 1. 2 8 07.. *. 1 2 2 3 9. *.1.

3 9 3 3. *.1.6 813.

  • 11
  • 1.5433
  • 1.3720
  • 1.5637
  • 1.2349
  • 1.5497
  • 1.2959
  • 1.2809 *

.8011 *

  • 1. 1403
  • 1.28.53.*. 1. 1275..*.1. 4214 *.1. 1350..*.1. 3506
  • 1 3577..*. 2.1504 *

.eeeeeee

..+.

.**ee eeeeee**

12

  • 1.2145
  • 1.5594 = 1.3794
  • 1.5540
  • 1.3195
  • 1.3500
  • 1.0785 *
  • 1. 4419 1.1298
  • 1.2757
  • 1.1316
  • 1.3271 a 1.2858
  • 1.6099
  • e.

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13

  • 1.4084
  • 1.3762
  • 1.4405
  • 1.3002
  • 1.3634
  • 1.2113 *

.6747

  • e.1. 2 4 31. *.1.2 712.. *. 1. 218. 4. *.1.

3 4 6 4. *. 1. 2 812.. *.1.

4 3 7 5.. *.2.

5 5. 4 5. *

. e 14

  • 1.3013
  • 1.3848
  • 1.2509
  • 1.2852
  • 1.0839 *

.6887 *

  • 1 3350.*. 1. 2574..*. 1. 3906
  • 1. 3537..*. 1. 6028
  • 2. 5031.*.

e..

ee..

eeee 15

  • 1.1245 *

.8215

  • 1.0260 *

.8032

. 1. 5316..*.2. 0954..*. 1. 6787..*. 2. 1446.* M-30B-Q

=

w-e w

i l

Catawba 2 Cycle 7 Core Operating Limits Report Page la of 144 Appendix A TABLE 1 (CONTINUED) 1 1

F-8UB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARCIN) - NORMAL OPERATION AT-100% POWER, 150 EFPD, THIS IS LEVEL 2 OF 18 l

(LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

....H.........Gee.....F.........E.........D.........C.........B.........A......

l 8*

.0054

  • 1.1835
  • 1.1160
  • 1.2723
  • 1.0324
  • 1.1920
  • 1.1428 *

.9596

  • 29.*. 1. 6494.*. 1. 4253..*.1. 4779.*. 1. 7468.*.
  • 2.1142
  • 1.4459
  • 1.5364
  • 1.34 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 9

  • 1.1835 *

.9832

  • 1.2659
  • 1.1310
  • 1.3002
  • 1.1813
  • 1.1931 *

.7272 *

-)

  • 1. 4459.*.1 7392..*. 1. 3552..*. 1. 5145.*.1 3100..*.1. 4392..*.1 41.69.*. 2. 3036.*

10

  • 1.1160
  • 1.2670
  • 1.1449
  • 1.2831
  • 1.1578
  • 1.2113
  • 1.0806 *

'568 *

  • 1. 5364
  • 1,3535
  • 1.4970
  • 1.3313..*. 1. 4712..*.1.4043..*.1 5635 *. 9560
  • e.

...eeeeeeeeeeeeeeeeeeeeeeee.

........ eeeeee...

....e 11

  • 1.2723
  • 1.1342
  • 1.2863
  • 1.0453
  • 1.2809
  • 1.1063
  • 1.0903 *

.6812

  • e.1 3 4 2 9.. *. 1. 510 3.. *. 1. 3 2 81..*.1.

6 311. *.1. 3 3 3 0. *.1.5 3. 42. *.1 5 5 01.. *.2.

4 6 21..

  • 12
  • 1.0324
  • 1.3066
  • 1.1642
  • 1.2852
  • 1.1138
  • 1.1578 *

.9286

  • j
  • 1. 6494.*. 1 3040.*. 1. 4642..*.1. 3291.*. 1. 5277..*.1. 4646.*. 1. 8158..*

l 13

  • 1.1920
  • 1.1956
  • 1.2145
  • 1.1106
  • 1.1620
  • 1.0399 *

.5923

  • I
  • 1. 4253..*. 1. 4335..*.1. 3997..*.1. 5299.*.1. 4590.*.1. 6255.*.2. 8332..*.

e.

14

  • 1.1428
  • 1.1952
  • 1.0828
  • 1.0935 *

.9339 *

.6040

  • eeee 779.*.1. 4159
  • 1. 5604
  • 1.5449.*. 1. 8067
  • 2.7751.*
  • 1.4

.ee.

..eeeeeee.

.eeeeeeeeeeees 15 *

.9596 *

.7272 *

.8579 *

.6822

  • 1. 7 4 6 8.*. 2. 3 060..*. 1. 9 5 43
  • 2. 4 57 3.*M-SUB-Q e.

eeeeeeeeee...

6 AT 100% POWER, 150 BFPD, THIS IS LEVEL 1 OF 18 i

I (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON)

E D

C B

A

[

e..H...... e e.G.........P. e e e e e e e e e..... e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e l

i 8 *

.5205 *

.4327 *

.6822 *

.4862 *

.6619 *

.8215 *

.7476 *

.5826

  • e. 3. 1915. *. 3. 8 4 4 2.. *. 2. 4 5 0 6.*.
3. 4 312.. *.2.5 0 9 4
  • 2. 019 3.. *. e e e. 2161
  • 2. 8 2 3 2.. *.

2 eeeeee.

9*

.4327 *

.6190 *

.4798 *

.7015 *

.5226 *

.7551 *

.7872 *

.4798 *

  • 3. 8442..*. 2. 6996..*.3. 4792..*.2. 3787..*. 3. 1788.*. 2. 1965.*.2. 1024
  • 3. 4242..*.

e.

eeeeee.

10

  • 6822 *

.4798 *

.6908 *

.4969 *

.7122 *

.8097 *

.6919 *

.3031 *'

. 2. 4506..*.3. 4792..*.2. 4186e**e.. 3. 3567..*. 2. 3366.*. 2. 0518

  • 2 3918.*eeee.3925
  • 5

.eeeeee...

eeeeee 11 *

.4862 *

.7036 *

.4980 *

.6737 *

.5087 *

.6994 *

.6865 *

.4370 *

. 3. 4312..*. 2. 3696.*. 3. 3464.*. 2. 4693.*. 3. 2622..*. 2. 3735.*.2. 4097..*. 3. 7556 *

..eee 12 *

.6619 *

.5259 *

.7154 *

.b098 *

.6983 *

.7315 *

.5837 *

  • 2.5094
  • 3.1602
  • 2.3266
  • 3.2524
  • 2.3795
  • 2.2640
  • 2 eeeeeeeeeeeeeeee.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 8306.*.

I 13 *

.8215 *

.7572 *

.8129 *

.7015 *

.7336 *

.6469 *

.3834 *

  • 2. 0193..*. 2. 1921.*.2. 0441
  • 2.3665.*.2. 2570.*. 2. 5550.*.4. 287.4.*

..e eee l

I 14 *-.7476 *

.7872 *

.6940 *

.6887 *

.5869 *

.3920

  • f
  • 2. 2161.*.2. 1024
  • 2.3866
  • 2.4017..*. 2. 8159..... 1984.*.
  • 4 eeeeeeeeeeeeeeeeen.

15 *

.5826 *..4798 *

.3042 *

.4380

  • 2.8232
  • 3.4200
  • 5.3886
  • 3.7491
  • M-SUB-Q
      • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

I l

l 1

i l

l

(

l Catawha 2 Cycle 7 Core Operating Limits Report -

Page 19 of 144 l

Appendix A I

l l

TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-C OP KARGIN) - NORMAL OPERATION AT 100% POWER, 415 BFPD, THIS IS LEVEL 18 OF 1B (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

F E

A e... H......... O...... e e e e e e e e e e e e......... D.........C......... B........ e e e e e e e 8*

.7219 *

.6415 *

.8954 *

.6812 *

.8675 *

.9746 *

.9061 *

.7411

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee* 4438
  • 1.7484
  • 1.6430
  • 2.0452
  • 1.5113
  • 1.9525
  • 1.5240 1.3514
  • 1 eeeeeeeeeeeeeee 9*

.6415 *

.8450 *

.6779 *

.9029 *

.6919 *

.9339 *

.9318 *

.6297 *

  • 2. 0452..*. 1. 5852..*.1. 9.986..*. 1. 4776.*.1. 9233..*. 1. 4223..*. 1 4112..*. 2. 0582..*

e.

10 *

.8954 *

.6779 *

.9082 *

.6790 *

.9082 *

.9650 *

.8611-*

.4477 *

. 1. 5113..*. 1. 9986.*.1. 4888.*.1. 98.50..*. 1. 4865.*.1. 4016..*.1. 5683.*. 2. 9653..*

11 *

.6812 *

.9029 *

.6801 *

.8514 *

.6587 *

.8675 *-.8407 *

.5998 *

. 1. 9 52 5.. *.1.47 3 9. *. 1 9 82 5.

  • e.1. 5 4 6 9. *.1 9 7 0 6. *.1.

5 0 3 5. *.1 5 8 0 4. *. 2. 2 3 3 0.. *.

e***

12 *

.8675 *

.6940 *. 9104 *

.6587 *

.8322 *

.8343 *

.7358 *

  • 1 5240..*.1 9139..*. 1. 4846.*. 1 9706.*. 1. 4272..*. 1 4477..*.1. 7594.*.

e..

13 *

.9746 *

.9350 *

.9660 *

.8686 *

.8354 *

.7446 *

.5409

  • e.1. 3 514. *. 1. 4197.. *.1.4 0 0 4. *. 1. 5 021.. *.1.

4 4 6 4. *.1.5 8 9 3.. *. 2. 3 3 9 8.

  • 14 *

.9061 *

.9318 *

.8622 *

.8418 *

.7360 *

.5462 *

  • 1. 4 4 3 8. *. 1. 4117.. +. 1. 5 6 8 3. *. 1. 57 8 9.. *.1.

7 57 4. *. 2. 317 7.. *.

15 *

.7411 *

.6297 *

.4477 *. 6 0 0 8

  • F-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeee 2330.*. M-SUB-Q
  • 2.0591
  • 2.9617
  • 2 e.1.

7 4 0 4 l

l AT 100% POWER, 415 EFPD, THIS IS LEVEL 17 OF 18 i

(LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTON)

H G

F E

C B

-A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee........D eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.9960

  • 1.3195
  • 1.2274
  • 1.3409
  • 1.1438
  • 1.2531
  • 1.1663
  • 1.0078
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.24.*.1. 4372..*.1. 3.051.*. 1. 3897
  • 1.5914
  • 1.6042
  • 1.2651
  • 1.3746
  • 1.23 eeeeeeeeeeeeee.

9

  • 1.3195
  • 1.1385
  • 1.3377
  • 1.2263
  • 1.3366
  • 1.2177
  • 1.1984 *

.8032 *

  • 1. 2651.e*eee.4713
  • 1.2575
  • 1.3615..*. 1 2366..*.1 3560..*.1. 36 5.*eee.0013
  • 1 2

e.

.. e eeeeeeeeeeeeeeeeeee..

... e eeeee.

10

  • 1.2274
  • 1.3377
  • 1.2456
  • 1.3409
  • 1.2156
  • 1.2359
  • 1.1256 *

.9628

  • I
  • 1.3746
  • 1 2575.*. 1. 3530e*eee.2515.*.1. 3833..*eee.3610
  • 1.4887
  • 1.7018
  • 1 1

e eeee.

eeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeee.

11

  • 1.3409
  • 1.2263
  • 1.3409
  • 1.1331
  • 1.3216
  • 1.1481
  • 1.1224 *

.7818

  • i

......... 1. 3595.*. 1 2510..*.1. 4729

  • 1.2579
  • 1.4365
  • 1 4792
  • 2.1303
  • l
  • 1.2324 *

........eeeeee.

12

  • 1.1433
  • 1.3409
  • 1.2177
  • 1.3227
  • 1.1395
  • 1.1578 *

.9769 e j

  • 1*.4372..*. 1 2332..*.1. 3813.*.1. 2570
  • 1. 3851.*.1. 3797..*.1. 6672..*.

e.

  • e 13
  • 1.2531
  • 1.2199
  • 1.2370
  • 1.1492
  • 1.1588
  • 1.0464 *

.7090

  • i

. 1. 3051.*. 1. 3535..*.1. 3601..*. 1. 4354

  • 1. 3787..*. 1. 5126.*. 2 2670..*.

14

  • 1.1663
  • 1.1984
  • 1.1267
  • 1.1224 *

.5810 *

.7144 *

  • 1 3887..*.1. 3659..*.1. 4876
  • 1.4781.*. 1. 6643..*. 2. 2486..*.

e..

ee

...eeeeee..

15

  • 1.0078 *

.8022 *

.9628 *

.7810

(

. 1. 5914 *... 2. 0034

  • 1 7018.*eeee.130.*3
  • N-SUB-Q 2

[

eeeee.....

ee i

l<

i

=

Catawba 2 Cycle 7 Core Operating Limits Report Page 20 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M.SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 100% POWER, 415 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEt,1 = BOTTOM)

....H.........G.........F...eeeeee.........D........C.........B.........A......

E 8

  • 1.1449
  • 1.5037
  • 1.3859
  • 1.5133
  • 1.2584
  • 1.3928
  • 1.2627
  • 1.1096 *
  • 1.5674
  • 1.2078
  • 1.3093
  • 1.1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.729..*e-1 3961.*.1. 2543..*.1.3776
  • 1.5519
  • e.....

. eeeeeeeeeeeeeeeee 9

  • 1.5037
  • 1.2702
  • 1.5197
  • 1.3827
  • 1.5048
  • 1.3377
  • 1.3184 *

.8579

  • e.1 2 07 8.. *.1.4 2 3 3.. *.1 19 3 3.. *. 1. 2 9 91. *.1.

17 9 8..*.1.3 27 2.. *.1.3 317.. *. 2. 0 0 3 2.. * -

10

  • 1.3859
  • 1.5187
  • 1.4052
  • 1.5165
  • 1.3591
  • 1.3837
  • 1.2284
  • 1.0667 *

. 1. 3093.*.1 1930.*eee.2940

  • 1.1970..*.1. 3373..*. 1. 3136.*.1. 4663.*.1 6485.*

1

...... e eeeeeeeeee.

11

  • 1.5133
  • 1.3827
  • 1.5165
  • 1.2563
  • 1.4908
  • 1.2745
  • 1.2466 *

.8579 *

  • 1.1729..*.1. 2983.*.ese.1970
  • 1.43.61.*. 1. 2141.*. 1. 4125.*.1 4481 *'2. 1012..*

1 e*ee.

eeeeeeeeee

......eee.

12

  • 1.2584
  • 1.5090
  • 1.3612
  • 1.4919
  • 1.3066
  • 1.3088
  • 1.0753
  • e.1. 3 9 61. *. 1. 17 71
  • 1. 3 3 5 6
  • 1.213 4.*. 1. 3 6 8 3.. *.1.3 5 9 9.*.1.6 613.
  • eeeeeeeeeeeeeeeee.

13

  • 1.3998
  • 1.3398
  • 1.3848
  • 1.2756
  • 1.3098
  • 1.1717 *

.7636

  • e.1. 2 5 4 3.. *.1.

3 2 4 0.. *. 1 3.12. 4. *.1.

4115.. *.1.3 5 81. *.1 5131...*. 2. 3 0 4 4.

  • 14
  • 1.2627
  • 1.3184
  • 1.2284
  • 1.2477
  • 1.0764 *

.7700 *

  • 1.3776.*.1. 3317.
  • 1. 4656.*. 1e.4471 *.1.6594
  • 2.2838.*.

eseeee..

eeeeeeeeeeeeeeeeee...

15

  • 1.1096 *

.8579

  • 1.0667 *

.8579

  • F-SUB-Q e.1. 5519..*. 2. 0032.*.1. 6485.*.2. 1012..* M-SUB-Q AT 100% POWER, 415 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

. B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1845
  • 1.5615
  • 1.4319
  • 1.5722
  • 1.2852
  • 1.4394
  • 1.2841
  • 1.1331 *
  • 1.5638
  • 1.1991
  • 1 eeeeeeeeeeeeeeeee.. 1. 2959
  • 1. 1595.*eee.3913
  • 1.2475
  • 1.3849e e e e e e e e e e e e e e e e e e e e e e e e.1.
55. 40..*.

9* 1.5615

  • 1.3045
  • 1.5787
  • 1.4255
  • 1.5530
  • 1.3666
  • 1.3495 *

.8675

  • e.1. 19 91. *.1.417 7.. *.1.17 6 4.*.1. 2 8 9 0..*.1.16. 9 8. *. 1. 3 2 9 0.. *. 1. 3 3 01. *. 2. 0121.
  • 10
  • 1.4319
  • 1.5787
  • 1.4469
  • 1.5701
  • 1.3977 a 1.4266
  • 1.2509
  • 1.0924 *
  • 1. 2959..*.1. 1757..*.1. 2840..*.1. 1833..*. 1. 3390..*.1. 3048 *...... 1. 4694.*.1. 6438..*.

e.

11

  • 1.5722
  • 1.4255
  • 1.5701
  • 1.2873
  • 1.5390
  • 1.3066
  • 1.2798 *

.8739

  • e.1 15 9 5.. *.1.2. 8 8 2.. *.1 18 3 3.. *.1.

4 3 9 9

  • 1. 216 5.. *.1. 4 27 7 *.1.4 57 4. *e e e e.118 8
  • 2

..eeeee**

e.

. ee. **.

eeeee.

12

  • 1.2852
  • 1.5562
  • 1.3987
  • 1.5390
  • 1.3420
  • 1.3495
  • 1.0978
  • e.1. 3 913.. *.1.167 2.. *.1.3 3 7 4. *.1 215. 8. *.1.

3 8 6 4. *. 1. 3 7 5 2.. *.1 6 8 0 3..

  • 13
  • 1.4394
  • 1.3687
  • 1.4276
  • 1.3077
  • 1.3505
  • 1.2017 *

.7743 *

  • 1. 2475.*.1. 3265..*. 1. 3029.*. 1. 4267..*.1 3734.*.1. 5396.*. 2. 3535.*.

e.

ee 14

  • 1.2841
  • 1.3495
  • 1.2509
  • 1.2798
  • 1.0999 *

.7808 *

  • 1.3849
  • 1.3301
  • 1.4694
  • 1.4574
  • 1.6856
  • 2.3338
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1331 *

.8675

  • 1.0924 *

.8739

  • 2.0121
  • 1.6446e e e e e e e e e e e e e e e e e e e e e e e e e e e.9 0.*.

M-SUB-Q 2.11

Catawba 2 Cycle 7 Core Operating Limits Report Page 21 of 144 Appendix A TABLE 1 (CONTINUED)

NORMAL OPERATION F-SUB-Q ts M-SUB-Q VALUES (F-SUB-Q OP MARGIN)

AT 100% POWER, 415 EFPD, THIS IS LI?RL la CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

'....H........G.........F.........B.........D.........C.........B.........A......

8

  • 1.1*03
  • 1.5219
  • 1.3902
  • 1.5347
  • 1.2424
  • 1.3966
  • 1.2413
  • 1.0978
  • t 1

1.4657

  • 1.3175
  • 1.4675
  • 1.6441
  • e.1. 6 4 0 3.
  • e e e. 2 5 5 3
  • 1. 3 6 0 0
  • 1.215 8 *

.... e eeeeeeeeeeeeeeeaseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.5219
  • 1.2649
  • 1.5390
  • 1.3827
  • 1.5090
  • 1.3227
  • 1.3088 *

.8365

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.e... 1 2320..*.eee.4061 + 1.4043
  • 2.1261 *
  • 1.2553
  • 1.4785
  • 1.2292
  • 1.3576
  • 1 eeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3902
  • 1.5390
  • 1.4019
  • 1.5305
  • 1.3548
  • 1.3859
  • 1.2092
  • 1.0981 *
  • 1.3600
  • 1.2292
  • 1.3507
  • 1.2387..*. 1 4013..*.1 3664.*.1. 5495.*eee.7339
  • 1 eeeene eeeeeeee**eeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5347
  • 1.3827
  • 1.5315
  • 1.2456
  • 1.4962
  • 1.2659
  • 1.2424 *

.8450 *

  • ee 2158..*. 1. 3576..*. 1 2380.*ee. 5106.*. 1. 2845.*.1. 5145..*.1. 5347
  • 2. 2215.*..

1...

  • 1 eeeeee.

12

  • 1.2424
  • 1.5123
  • 1.3559
  • 1.4962
  • 1.3002
  • 1.3098
  • 1.0635 *
  • 1. 4 6 57.. *.1.2 2 8 9.*e e e e. 3 9 9 4
  • 1. 2 8 37..*. 1. 47 8 9.. *.1. e. 4 6 4 9. *.1. e.7 9 8 3
  • 1 ee....
    • eseeeeee.

ees..

eeeee.-

13

  • 1.3966
  • 1.3238
  • 1.3869
  • 1.2670
  • 1.3120
  • 1.1652 *

.7454 *

. 1. 3175..*. 1. 4036.*.1. 3.655.*.1. 5.134.*. 1. 4629..*.1 6474.*.2. 5144..*.

14

  • 1.2413
  • 1.3088
  • 1.2092
  • 1.2424
  • 1.0646 *

.7518 *

. 1 4675.*. 1. 4048.*. 1. 5495.*. 1 5347..*. 1. 7953

  • 2.4935
  • eeeeeeeeeeeee.

15

  • 1.0978 *

.8365

  • 1.0581 *

.8439

  • 1.6441
  • 2.1275
  • 1.7348
  • 2.2238.* M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

AT 1004 POWER, 415 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 m TOP 07 CORE, LEVEL 1 = BOTTOM) e...H.........G.......F.........E.........D....... e e e e e e e e e e e e e e e e e e e e e e e e e,

j C

B A

8

  • 1.1503
  • 1.5200
  • 1.3891
  • 1.5422
  • 1.2402
  • 1.3977
  • 1.2413
  • 1.0999 *

)

. e e e e e e e e e e e e e e e e e e e e e e.0 3. e

  • e e e.2 42 6.. *.1.

5 0 0 6.*.1. 3 5 53..*. 1. 5110..*. 1. e. 6 871 *

  • 1.6636
  • 1.2781
  • 1.39 1

e e.

eeeee.

9

  • 1.5208
  • 1.2627
  • 1.5455
  • 1.3816
  • 1.5112
  • 1.3205
  • 1.3109 *

.8375

  • I
  • 1. 2781.*. 1. 5032..*.1. 2.498.... 1. 3 9 21.. *.1.

2 6 6 2.. *. 1. 4 4 61. *. 1. 4 4 0 7.. *. 2. 17 3 9..

  • 10
  • 1.3892
  • 1.5455
  • 1.3987
  • 1.5380
  • 1.3537
  • 1.3891
  • 1.2081
  • 1.0603 *
  • *
  • e. 9 0 3. *. 1. 2 4 9 8. *.1.

3 8 2 5. *. 1. 2 5 8 8.*.

1. 4 3 3 0.. *.1 3 914. *. 1. 5 815.. *.1.

7 7 3 0..

  • 1.3...

11

  • 1.5422
  • 1.3816
  • 1.5300
  • 1.2424
  • 1.4962
  • 1.2659
  • 1.2456 *

.8450 *

  • 1.2425
  • 1.3921
  • 1.2583
  • 1.5321
  • 1.3052
  • 1.5429
  • 1.5547
  • 2.2629
  • ee*****eeeeeeeee***eeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*

1.4973

  • 1.2981
  • 1.3130
  • 1.0646
  • 12
  • 1.2402
  • 1.5133
  • 1.3548

. 1 5006..*.1 2627..*.1. 4317..*.1. 30.47..*. 1. 5175..*.1. 4978.*.1. 8327..*.

13

  • 1.3977
  • 1.3216
  • 1.3902
  • 1.2659
  • 1.3152
  • 1.1674 *

.7454 *

  • 1. 3553..*. 1. 4445..*.1. 3908.*. 1. 5417..*. 1. 4964
  • 1. 6878..*. 2. 5643.*.

14

  • 1.2413
  • 1.3109
  • 1.2081
  • 1.2456
  • 1.0667 *

.7518 *

  • 1 5110.*. 1. 4407.*. 1. 5823.*. 1. 55.47..*. 1. 8312..*. 2. 5416..*

eeee 15

  • 1.0999 *

.8365

  • 1.0603 *.8450
  • 1. 6871
  • 2.17 47
  • 1.773 5
  • 2.2 653
  • M-SUB-Q

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee

=

I Catawba 2 Cycle 7 Core Operating Limits Report Page 22 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION l

AT 100% POWER, 415 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 =. TOP OF CORE, LEVEL 1 = BOTTOH)

H G

F C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeee...Ee e e e e e e..D..'..... e e e e e e e e.

eeeeeeeeeeeeeeeeee 8* 1.1235

  • 1.4919.*.1.3591
  • 1.5155
  • 1.2124
  • 1.3698
  • 1.2156
  • 1.0796 *
  • 1.7486
  • 1.3385
  • 1.4552
  • 1.3001
  • 1.5848 *'1.4249
  • 1.5879
  • 1.7718 *
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.4919
  • 1.2338
  • 1.5187
  • 1.3516
  • 1.4844
  • 1.2927
  • 1.2063.*

.8193 *

. 1. 3385.*. 1 5809.+. 1. 3022..*.1. 4601.*. 1 32ee.*.1. 5154.*ee 5074.*.2. 2915..*

1 j

63 L

.1.3645

  • 1.1835
  • 1.0309
  • 10 *-1.3591
  • 1.5187
  • 1.3677
  • 1.5101
  • 1.3248
  • 1. 4 552. e
  • e e e. 3 027
  • 1. 4 47 8
  • 1. 3106
  • 1. 4 9 53
  • 1. 4 458
  • 1. 6 506
  • 1. 8550
  • 1 eeee...

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.5112

  • 1.2145
  • 1.4683
  • 1.2391
  • 1.2231 *

.8268

  • 11
  • l.5155
  • 1.3516
  • e.1. 3001
  • 1.4601
  • 1. 3103..*.1. 6100 *.1.3626
  • 1.6079
  • 1 6156.*.2. 3520.*.

.eeeeeeeeeeeeee

..eeeeeeeeeeeeeeeeeeeeeeee 12

  • 1.2124
  • 1.4876
  • 1.3259
  • 1.4694 *.1.2702
  • 1.2895
  • 1.0432 *
  • 1.5848
  • 1.3217
  • 1.4932
  • 1.3617
  • 1.5740
  • 1.5456
  • 1.9013
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 1.2938
  • 1.3645
  • 1.2402
  • 1.2906
  • 1.1460 *

.7283

  • 13
  • 1.3698 *

. 1. 4249......1. 5144.*. 1 4449..* 1. 6067..*eee.5441.*.ee 7404

  • 2. 6584..*

1 1

eee.

...e..

14

  • 1.2156
  • 1.2863
  • 1.1835
  • 1.2231
  • 1.0453 *

.7358 *

  • 1.5879
  • 1.5084
  • 1.6 1

1.9996

  • 2.6342
  • eeeeeeeeeeeeeeeeeeeeee.518.e*eee.6194
  • e eeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.0796 *

.8182

  • 1.0389 *.8257
  • F-SUB-Q e e e e e e ee e e e e e e e e e e e e e e e.55
  • 2.3 546
  • M-SUB-Q 1.7718
  • 2.2923
  • 1.85..eeeeeeeeeee AT 100% POWER, 415 EFPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A-i I

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 8

  • 1.0967
  • 1.4630
  • 1.3291
  • 1.4876
  • 1.1845
  • 1.3430
  • 1.1910
  • 1.0581
  • j 1.4033
  • 1.5373
  • 1.3692.* 1.6958
  • 1.5029
  • 1.6775
  • 1.8682 *
  • 1.8639
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.4630
  • 1.2059
  • 1.4898
  • 1.3216
  • 1.4566
  • 1.2649
  • 1.2627 *

.5000 *

. 1 4033.*.1. 6825.*. 1. 3698.*. 1. 5442..*.eee.3947

  • 1.5992
  • 1.5864
  • 2.4438
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

10

  • 1.3291
  • 1.4898
  • 1.3366
  • 1.4823
  • 1.2959
  • 1.3388
  • 1.1588
  • 1.0174 *
  • 1.5373
  • 1.3698
  • 1.5290
  • 1.3767
  • 1.5733
  • 1.5138
  • 1.7357
  • 1.9493
  • l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.4876
  • 1.3205
  • 1.4823
  • 1.1877
  • 1.4405
  • 1.2124
  • 1.1995 .0075
  • eeeeeeeeeeeeeeeeen... 3759
  • 1.7062
  • 1.4242
  • 1.6845
  • 1.6850
  • 2.4635 *
  • 1.3692
  • 1.5442'* 1

.eeeeeeeee...ese....

..seeen..............eeeeeeee.

12

  • 1.1845
  • 1.4598
  • 1.2970
  • 1.4416
  • 1.2424
  • 1.2659
  • 1.0217
  • 1.3920
  • 1.5722
  • 1.4236
  • 1.6566
  • 1.6168
  • 1.9886 *
  • 1.6958
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3430
  • 1.2659 *'1.3388
  • 1.2134
  • 1.2670
  • 1.1224
  • 7111 *-

j

  • 1.5029
  • 1.5980
  • 1.5134
  • 1.6831
  • 1.6156
  • 1.8216 *'2.8120 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.1910
  • 1.2627
  • 1.1578
  • 1.1995
  • 1.0228 *

.7176

  • e e e e.7 7 5. *e e. 5 87 2.. *.1.

7 3 6 2

  • 1. 6 8 5 8
  • 1. 9 8 67.. *.2.

7 8 52.. *.

  • 1.6 1

eee eeeeeeeee eeeeeeeee 15

  • 1.0501 *

.8000

  • 1.0174 *

.8065

  • 1.8683
  • 2.4438.*. 1. 9511..*.2 4673..*. N-SUB-Q eeeeeeeeeeeeee..

Catawba 2 Cycle 7 Core Operating Limits Report Page 23 of 144 Appendix A TABLB 1 (CONTINUED)

F-SUB-Q f M-SUB-Q VALUES (F-SUB-Q OP MARQIN) - NORMAL OPERATION AT 100% POWER, 415 EFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18. TOP OF CORE, LEVEL 1 = BOTTOM)

H O

B A

      • ee......ee.........F.........E.........D........Ceeeeeeeeeeeeeeeeeeeeeeen 8
  • 1.1031
  • 1.4758
  • 1.3377
  • 1.5037
  • 1.1899
  • 1.3548
  • 1.1995
  • 1.0667
  • l e.1 9557..*.1. 4584.*. 1 6057..*.1. 4225.*.1. 7870.*.1. 5626.*eeee.7445
  • 1.9350
  • 1 eeeeeeeeeeeeee.

1 9

  • 1.4759
  • 1.2113
  • 1.5058
  • 1.3291
  • 1.4726
  • 1.2723
  • 1.2745 *

.8065 *

. 1. 4584..*. 1. 7722...*.1 4222..*.1. 6129..*.1. 4459......1. 6641.*.1. 6452.*.2. 5558.*e

  • 1.3516
  • 1.1652
  • 1.0260
  • 10
  • 1.3377
  • 1.5058
  • 1.3441
  • 1.4983
  • 1.3034
  • 1. 6 0 57.. *.1.42 2 2.. *.1.5 9 67.. *. 1. 42 7 2.. *. 1. 6 3 7 7.. *.1 5 6 6 4. *. e e e. 7 9 7 6
  • 2. 014 8
  • 1 e.

.ee eeeeee.

  • 1.2102 *

.8129

  • 11
  • 1.5037
  • 1.3291
  • 1.4983
  • 1.1931
  • 1.4523
  • 1.2199

. 1 4225

  • 1. 6133.*. 1. 4268.*.1. 7899.*.1. 4700.*. 1. 7380.*. 1. 7348.*.2. 5385.*
  • 1.2777
  • 1.0292
  • 12
  • 1.1999
  • 1.4758
  • 1.3045
  • 1.4533
  • 1.2499 ~
  • 1. 7870..*. 1. 4433.* 1. 6365.*. 1. 4700.*.1. 7029..*.1 65.40
  • 2.0349.*

e.

.e

.eeeeee...

13

  • 1.3548
  • 1.2734
  • 1.3516
  • 1.2209
  • 1.2788
  • 1.1320 *

.7154

  • 1.5626'* 1.6633
  • 1..5656
  • 1.7371
  • 1.6528
  • 1.8614
  • 2.e.8952 eeeeeeeeeeeeeeeeeeeeeeee....

eeeee*

eeeeeeeeeeeeeeeeeeee.

14

  • 1.1995
  • 1.2734
  • 1.1652
  • 1.2102
  • 1.0303 *

.7229

  • i

. 1. 7445.*.1 6457..*. 1. 7986.*.1. 7362..*. 2. 0330.*.2. 8682..*.-

15

  • 1.0667 *

.8054

  • 1.0249 *

.8118

  • F-8UB Q j
  • 1. 9 3 50.*. 2 556 9.*.2. 0160 *.2. 542 5.* M-SUB-Q AT 100% POWER, 415 EFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.......eeeeeeee 8

  • 1.0806
  • 1.4533
  • 1.3120
  • 1.4812
  • 1.1652
  • 1.3323
  • 1.1770
  • 1.0485 *
5..' *. 1 5 212.. *.1.9 2 21.. *. 1. 6 6 7 6.. *. 1. 8 6 2 6. *. 2. 0 611. *.
  • 1.5495
  • 1.716 e 2.0729 eeeeeeeeeeeeeeeeee**ee.

9

  • 1.4533
  • 1.1867
  • 1.4833
  • 1.3034
  • 1.4501 + 1.2477'* 1.2531 *

.7893

  • e.1 5 4 9 5. *. 1. 8 919. *. 1 5212.. *. 1. 7 2 8 8.. *. 1. 5 4 51.. *. 1. 7 7 9 9. *. 1. 7 52 6. *. 2. 7 3 8 6..
  • 10
  • 1.3120
  • 1.4833
  • 1.3173
  • 1.4748
  • 1.2777
  • 1.3291
  • 1.1428
  • 1.0067 *
14. *. 1. 9187.. *. 2. 14 47.. *.
  • 1.7165
  • 1.5212
  • 1.7097
  • 1.5266
  • 1.7540
  • 1.67 e eeeeeeeeeee

.eeeeee**eeeeeeeeeeeeeeeeeeeeeeeee..

11

  • 1.4812
  • 1.3034
  • 1.4758
  • 1.1695
  • 1.4298
  • 1.1963
  • 1.1888 *

.7958

  • eeeeeeeeeeeeeeeeeeeeeeeeee........... 1. 5652 *....... 8546
  • 1.8467.e* 2.7077 *
  • 1.5212
  • 1.7288
  • 1.5255
  • 1.9204
  • 1 12
  • 1.1652
  • 1.4523
  • 1.2736
  • 1.4309
  • 1.2252
  • 1.2563
  • 1.0100 *
  • 1. 9221.*. 1 541.8.*.1. 7526.*. 1. 5640 *. 1. 8158..*.1. 7554.*.2. 1640.*.-

1 13

  • 1.3323
  • 1.2488
  • 1.3302
  • 1.1963
  • 1.2574
  • 1.1117 *

.7004 *

  • 1. 6676
  • 1. 7785.*. 1. 6714..*. 1. 8546.*. 1. 7540.*. 1. 9747..*. 3. 0946.*.

14

  • 1.1770
  • 1.2520
  • 1.1428
  • 1.1888
  • 1.0110 *

.7069 *

  • 1. 8626..*. 1. 7540.*. 1 9204.*.1. 8.483.*.2. 1619..*. 3. 0639.*.

e.

15

  • 1.0485 *

.7893

  • 1.0067 *

.7947

... 0611 ** 2...... 2. 7420.*. 2. 1447..*. 2. 7111..*e M-SUB-Q i

I I

l i

l

Catawba 2 Cycle 7 Core Operating Limits Report :

Page 24 of 144 Appendix A TABLE 1 (CONTINUBD)

F-SUB-Q & M-SUB-Q VALUES (F-SUS-Q OP MARGIN) - NORMAL OPERATION

]

AT 100% POWER, 415 MFFD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)-

O F

E D

'C B

'A e...H*eeeeeeeeeeeeeeeeeeeeeeeeeee...eeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeee 8

  • 1.1053
  • 1.4940
  • 1.3409
  • 1.5208
  • 1.1899
  • 1.3645 + 1'2038
  • 1.0742 *
  • -1.9480..*. 1. 4499..*.1 6142..*.l.4270.*.1 8112
  • 1 5789
  • 1.7740
  • 1.9632
  • eeeee ee.

.... eeeeee.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.4940 * '1.2124
  • 1.5240
  • 1.3323 *'1.4887
  • 1.2745 8.1.2831 *

.8075 *

'* 1. 4499..*. 1 7799

  • 1.4251
  • 1.6251.*.1. 4558
  • 1.6897
  • 1 6689 2.6089
  • e.

..eeeeeeeeeeeeee....

.. eeeeeeeeeeeeee eeeeeeeeeeeeee.

10

  • 1.3409
  • 1.5240
  • 1.3452
  • 1.5144'* 1.3045
  • 1.3612
  • 1.1685
  • 1.0314 *

. 1. 6142.*. 1. 4251.*. 1. 6106.*.1 4336.*.1 6561e*eeee.5846

  • 1.8296
  • 2.0447 *

- i 1

eeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5208
  • 1.3313
  • 1.5144
  • 1.1942
  • 1.4630
  • 1.2220
  • 1.2177 *~.8140 *.
  • 1. 4270..*. 1. 6263.*.1. 4336..*. 1. 8082.
  • 1. 4756.*.1. 7626.*. 1 7611..*.2. 5905.*..

12

  • 1.1899
  • 1.4908
  • 1.3055
  • 1.4641
  • 1.2509
  • 1.2863
  • 1.0335 *
  • 1.8112..*. 1.e.4528
  • 1.6548
  • 1.4756.*e.1. 7233
  • 1 6740..*. 2. 0709.*

eseeen.

eeeeeeeeeeeeeeeeeee..

.e...

.ec 1

13

  • 1.3645
  • 1.2745
  • 1.3623
  • 1.2231
  • 1.2873
  • 1.1385 *'.7165 *

]

eneeseseeeeeeeeeeee.1 5841.. 1. 7626.*. 1 6727

  • 1.8853
  • 2.9715 *
  • 1.5789
  • 1.6897 *

. eeeeeeeeeeeeeeeeeeeeeee -

- 14

  • 1.2038
  • 1.2820
  • 1.1674
  • 1.2177
  • l'0346 *-

.7229'*

l j

-. 1. 77 4 0..*. 1. 6 6 8 9..*. 1. 8 311.. *. 1. 7 611.. *. 2. 0 6 9 0..*. 2. 9 43 2..*. -

f 15

  • 1.0742 *

.8075'* 1.0303 *

.8129

. 1. 9632...*.2 6089..*. 2 0448..*.2. 5936.* M-sUB-Q i

l l

AT 100% POWER, 415 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM) '

.e..H........G.........F.........E........D.........C......... B.. e e e.... A.......

8

  • 1.1160
  • 1.5165
  • 1.3559
  • 1.5433
  • 1.2006
  • 1.3816-* 1.2156
  • 1.0871 *-

r eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.505.'*.1. 7176.*.1 4894.*. 1 6771..*.1. 8.550.*;

  • 1.8610
  • 1.3764
  • 1.5353
  • 1.3...

l.

.. e i

9

  • 1.5165
  • 1.2252
  • 1.5465
  • 1.3462 *:1.5090
  • 1.2863
  • 1.2981 *'.8150 *
  • 1. 3764.*. 1. 6952..*.1. 3497.
  • 1. 5451..*.1. 3760..*eee.5995
  • 1.5747
  • 2.4718
  • 1 l

I.

e eeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3559
  • 1.5455
  • 1.3580
  • 1.5347
  • 1.3184
  • 1.3784
  • 1.1802
  • 1.0421 *
  • 1. 5353.*. 1. 3497..*.1. 5320 *.. 1. 3 57 2.. *. 1. 5719.. *.1.4 9 67.. *..1.

7 2 9 6. *. 1. 9 312.. * -

11

  • 1.5433
  • 1.3452
  • 1.5358
  • 1.2049
  • 1.4823
  • 1.2338
  • 1.2327 *..8215 *

~

i e e e e e e e e e e e e e e e.1.* e e e.3 572. e *e.1 7 2 07..*.

1. 4003.*. 1.6714
  • 1. 659 4
  • 2. 4 523
  • 1.3505
  • 1.545.

1 j

eee 12

  • 1.2006
  • 1.5112
  • 1.3184
  • 1.4833
  • 1.2627'* 1.3023
  • 1.0442
  • i a
  • 1.7176..*.1. 3735..*.1. 5708..*.1. 3.994.*.1 6.442..*. 1. 5860
  • 1.9532
  • eeeeee eeeeeeeeeeeeee 13
  • 1.3816
  • 1.2873
  • 1.3784
  • 1.2349
  • 1.3034
  • 1.1524 *

.7219 *

. i e e * *

  • e e e e e e e e e e e e e e e e e e e e e e e e e e e.14. *.1.

5 8 4 8.*.1. 7 8 61. *.2.8 0 6 4.

  • 1.4894
  • 1.5983
  • 1.4967
  • 1.67..

4 i

14

  • 1.2156
  • 1.2970
  • 1.1792
  • 1.2316
  • 1.0464 *

.7294 *

  • 1. 6771..*. 1. 5748..*. 1 7309.*. 1. 6607
  • 1.9514
  • 2.7777 *-

eeeeeeeeeeeeeeeeee**e*e 15

  • 1.0871 *

.8150 *.1.0421 *

.8204-* F-SUB-Q

[

  • 1. 8550
  • 2. 4719.*. 1. 9328.*. 2. 4551
  • M-SUB-Q

.eeee.

t l-J t

m e-e-

n-

,wn v

, ~

wy,, -

3 t

]

Catawba 2 Cycle 7 Core Operating Limits Report Page 25 of 144 j

Appendix A TABLE 1 (CONTINUED) l F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 100% POWER, 415 EFPD, THIS IS LEVEL 6 OF 18 m TOP OF CORE, LEVEL 1 m BOTTON)

I (LEVEL 18 s

J H

O F

B D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 8*

1.1192

  • 1.5272
  • 1.3623
  • 1.5530
  • 1.2038
  • 1.3880
  • 1.2199
  • 1.0903
  • 1

. 1. 7783..*. 1. 3090.*. 1. 4648.*. 1. 2862..*.1. 6438..*. 1 4220

  • 1.6032
  • 1 7738.*

j

. eeeeeeeeeeeeeee..

a

  • 1.2906
  • 1.3045 *

.8150

  • l 9* 1.5272
  • 1.2295
  • 1.5572
  • 1.3516
  • 1.517F 1.3110
  • 1.5286
  • 1.5018
  • 2.3715 *
  • 1.3090..*.1. 6184.*. 1. 2840
  • 1.4748
  • eeeeee.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeweeeeeeeeeeeeen 10

  • 1.3623
  • 1.5562
  • 1.3634
  • 1.5444
  • 1.3227
  • 1.3859
  • 1.1824
  • 1.0442
  • 1.4648
  • 7
  • 1.8481
  • eeeeeeeeee.1. 2847..*.1. 4619
  • 1.2924
  • 1.5013
  • 1.4269
  • 1.654

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.5530
  • 1.3516
  • 1.5455
  • 1.2001
  • 1.4908
  • 1.2370
  • 1.2370 *

.8204

  • ee._,e 2.*.1. 47.58.*eee.2924.e. 1. 6428.*. 1. 3313..*.1. 5954.*. 1. 5822
  • 2.3509
  • ' 96 1

eee.

.ee

.eeee**eeeeeeee 1.5197

  • 1.3238:* 1.4908
  • 1.2659
  • 1.3088
  • 1.0464
  • 12
  • 1.2038
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.1 5076
  • 1.8648 *
  • 1.6438
  • 1.3087
  • 1.5002
  • 1.3305
  • 1.5646 *

.. eeeeeeeeeeee 13

  • 1.3880
  • 1.2906
  • 1.3859
  • 1.2381
  • 1.3098
  • 1.1556 *

.7208

  • e 1.4220
  • 1.5276
  • 1.4269
  • 1.5943..*.1. 5056.*. 1. 6995.*. 2. 6878
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

..ee 14

  • 1.2199
  • 1.3034
  • 1.1813
  • 1.2370
  • 1.0474 *

.7283

  • j
  • 1. 6032..*. 1. 5029..*.1. 6548.*.1. 5834
  • 1. 9632...*.2.

6614

  • e.

15

  • 1.0903 *

.8140

  • 1.0442 *

.8193

eeeeeeeeeeeeen.39

  • 1.8497
  • 2.3534
  • N-SUB-Q
  • 1.7738
  • 2.37 eeeeeeeeeeeeeeeeeeeeee AT 100% POWER, 415 EFPD, THIS Is LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

H O

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1674
  • 1.6001
  • 1.4212
  • 1.6258
  • 1.2541
  • 1.4501
  • 1.2713
  • 1.1374 *
  • 1.634 1

1.3036

  • 1.4709
  • 1.6222
  • eeeeee.1.*eee.2009
  • 1.3482
  • 1.1801
  • 1.5107
  • eeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-4 9* 1.6001
  • 1.2831
  • 1.6301
  • 1.4105
  • 1.5883
  • 1.3452
  • 1.3612 *

.8493 *

. 1 2 00 9..*.1. 4 8 9 3. *.1 17 8 7.. *.1.

3. 57 7.. *...1 2027..*.1 4051.*. 1. 3765.*.2. 1719 8

4

.... e 10

  • 1.4212
  • 1.6301
  • 1.4223
  • 1.6172
  • 1.3784
  • 1.4469
  • 1.2327
  • 1.0892 *
  • 1.3482
  • 1.1793
  • 1.3466
  • 1.1866
  • 1.3815
  • 1.3092
  • 1.5187
  • 1.6924
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeees 4

11 a 1.6258

  • 1.4105
  • 1.6172
  • 1.2595
  • 1.5583
  • 1.2895
  • 1.2916 *

.8536

  • e.1. 1801.*.1. 3h77
  • 1.1866
  • 1.5116..*. 1. 2231.*.1. 4685.*. 1 4518.*. 2. 1587..*.

eeeeeeeeeeeeeeeeeee.

12

  • 1.2541
  • 1.5904
  • 1.3794
  • 1.5594
  • 1.3184
  • 1.3655
  • 1.0913
  • j
  • 1. 5107..*. 1. 2013.*. 1. 3006.*. 1. 222.4.*.1. 4407..*.1. 3851..*. 1. 7137..*

i 13

  • 1.4501
  • 1.3452
  • 1.4469
  • 1.2895
  • 1.36(6
  • 1.2059 *. 7497 *
  • 1. 3036.*.1.e.40.ee.* 1. 3100.*. 1. 4676.*.1. 3842
  • 1 5615..*.2. 4715.*.

43 e

eee.ee 1

14

  • 1.2713
  • 1.3602
  • 1.2316
  • 1.2906
  • 1.0924 *

.7583

  • i
  • 1. 4709... 1 3774.*. 1. 5198.*.1. 4528...... 1. 712 3..
  • 2. 4 4 6 4.. *.

15

  • 1.1374 *

.8482

  • 1.0881 *

.8525

. 1. 6 2 2 2..*. 2.17 41

  • 1. 6 9 3 7. e *e e e e.16 3 0..
  • N-SUB-Q 2

ee eee.eeeeee e..

M 4

I i

1 -

4 1

I I

Catawba 2 Cycle 7 Core Operating Limits Report Page 26 of 144 Appendix A TABLE 1 (CONTINUED)

F-8UB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 100% POWER, 415 BFFD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.2649

  • 1.4651
  • 1.2841
  • 1.1481
  • 8*

1.1738

  • 1.6140
  • 1.4351
  • 1.6418
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen.16..*eee.2245
  • 1.3819
  • 1.5289 *
  • 1.5385
  • 1.1272
  • 1.2668
  • 1.1088
  • 1.42 1 eeeeeeeeeeeeeeeeeeeeeeee 9 *'1.6140
  • 1.2948
  • 1.6461
  • 1.4234
  • 1.6022
  • 1.3580
  • 1.377J *

.8536 *

  • 1.1272 e 1.3999
  • 1.1076
  • 1.2759
  • 1.1306
  • 1.3203
  • 1.2918
  • 2.0535
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-

- 10

  • 1.4351'* 1.6451
  • 1.4362
  • 1.6322
  • 1.3902
  • 1.4641
  • 1.2434
  • 1.0967 *

. 1 2 6 6 8.. *. 1. 107 6..*.1.

2 6 5 3.. *. 1. 114 6. *. 1. 2 9 8 5. *. 1. 2 2 81. *.1.

42. 8 8..* e 1. 5 9 8 4
  • eeeeeee.

11

  • 1.6418
  • 1.4234
  • 1.6322
  • 1.2702
  • 1.5744
  • 1.3002
  • 1.3045 *

.8557 *

  • .1.1088
  • 1.2766
  • 1.1141
  • 1.4197
  • 1 1.3633
  • 2.0456
  • eeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeee.. 1 1444.*eeee.3789
  • eeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2649
  • 1.6054
  • 1.3912
  • 1.5754 + 1.3302
  • 1.3816.* 1.0999
  • e.1. 4216..*.1. 1288
  • 1.2977..*eeee.1438 *-1.3501
  • 1.2948.*.1. 6103.*

1 eeeeeeeeee eeeeeeeeeeeeeeeeee....

eeeee 1.4651

  • 1.3591
  • 1.4641
  • 1.3002
  • 1.3827
  • 1.2177 *

.7529

  • 13
  • 1.2245
  • 1.3195
  • 1.2281
  • 1.3780
  • 1.2932
  • 1.4618
  • 2.3329
  • l eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees

(

14

  • 1.2841
  • 1.3762
  • 1.2424
  • 1.3034
  • 1.1010 *

.7604 *'

e.1. 3 819. *.1.2 9 2 6.. *.1.

4 2 9 8.. *.1. e. 3 6 4 2. *.1.

6 0 91.. *. 2. 3 07 8. *.

eee.

ee e.e.

15

  • 1.1481 *

.8536

  • 1.0956 *

.8b57

  • 1.5289.*.e. 0555
  • 1. 5996..*.2. 0477..*. M-8UB-Q 2

e.ee...

..ee.

l AT 100% POWER, 415 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F D

B A

eeeeeeeeeee..eeeeee....ee.....E..eeeeeeeeeeeee...C..eeeeeeeeeeeeeeeeeeeee.

i j

1.4533

  • 1.6665
  • 1.2873
  • 1.4919
  • 1.3173
  • 1.1727
  • 8* 1.1856
  • 1.6376 *

. 1. e. 4 5 f 1

  • 1. 0 6 4 5.. *. 1. 19 8 3. e *.1.
0. 4 8 0.. *. 1. 3 4 0. 4.
  • 1. 15 2 8. *.1.

2 9 3 9.

  • e e e. 4 3 6 6
  • 1 eeeee..

s eeeee.

9

  • 1.6376
  • 1.3141
  • 1.6708
  • 1.4426 *.1.6258
  • 1.3869
  • 1.4094 *

.8739 *

  • 1. 0645.*. 1. 3219..*.1.e.0474
  • 1.2071
  • 1.0691
  • 1. 2397..*.1. 2110..*. 1. 9287
  • e.

.ee eeeeeeeeeeeeeeeeeeeeee, e

. eee.

l 10

  • 1.4533
  • 1.6697
  • 1.4566
  • 1.6536
  • 1.4116
  • 1.4919
  • 1.2733
  • 1.1160 *

.eeeeeeeseeeeeeeeee 1541

  • 1.3409 *. 5083
  • e.1. 1983..*. 1. 0479..*. 1. 1956.*.1.0553
  • 1.2254
  • 1

.eeeeeeeeeeeeeee esee 11

  • 1.6665
  • 1.4426
  • 1.6536
  • 1.2927
  • 1.6022
  • 1.3259
  • 1.3313 *. 8 6. 7 *
  • 1. 0480..*. 1. 2071
  • 1.0548
  • 1.3371..*. 1 0777..*eee.2953
  • 1.2808
  • 1.9340
  • 1 i

eeeeeeeeeeeeeeeeeeeeeee.

. eeeeeeeeeeeeeeee 12

  • 1.2873
  • 1.6279
  • 1.4126
  • 1.6033
  • 1.3548
  • 1.4105
  • 1.1245 *
  • 1.3404
  • 1.0670
  • 1.2246
  • 1.0766 + 1.2683
  • 1.2131
  • 1.5105
  • l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 13

  • 1.4919
  • 1.3880
  • 1.4930
  • 1.3259
  • 1.4116
  • 1.2456 *

.7700 *

. 1. 1528..*. 1. 2389.*. 1. 1541.*. 1. 2945..*e 2124.*.1. 3683..*.2. 1849

  • 1 ee eeeee.

14

  • 1.3173
  • 1.4084
  • 1.2702
  • 1.3313
  • 1.1256
  • 7786 *
  • 1. 2939
  • 1. 2125..*.1.e.3418..*.1. 2815 8. 1. 5084
  • 2. 1626.*

e..

15

  • 1.1727 *

.8729

  • 1.1149 * '.868 6
6. *.1. 9 2 87..
  • e e e. 5 0 9 5
  • 1.9357
  • M-sUB-Q 1
  • 1.436 eeeeeeeeeeee...

eeeeee.

i l

l l

r I

Catawba 2 Cycle 7 Core Operating Limits Report Page 27 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-8UB-Q VALUES (F-SUB-Q OP KARGIN) - NORK,. OPERATION AT 100% POWER, 415 BPPD.

THIS IS LEVEL 2 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

D C

B A

e...H.........O.........F.........E.......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8

  • 1.0903
  • 1.4898
  • 1.3334
  • 1.5187
  • 1.1995
  • 1.3944
  • 1.2520
  • 1.0924 *

. 1. 5382..*.1. 1322.*.1. 2667..* 1. 1084.*.1 3934.*e.1. 1943

  • 1 3199..*. 1 4977..*

.eeeeee 9

  • 1.4898
  • 1.2134
  • 1.5208
  • 1.3216
  • 1.4887
  • 1.3034
  • 1.3227 *

.8332

  • e.1. 13 2 2.. *.1.3 8 57.. *. 1 10 9 4. *. 1. 2 7 5 9. *.1.

12 4 3.. *.1.27 71.. *. 1. 2 511

  • 1. 9 6 2 4.
  • eeeeee.

10

  • 1.3334
  • 1.5197
  • 1.3355
  • 1.5090
  • 1.3055
  • 1.3923
  • 1.1995
  • 1.0303 *
  • 1. 2667..*. 1 1100.*. 1. 2630
  • 1.1131
  • 1.2845
  • 1.1983
  • 1.3778
  • 1. 5867..*.,

e.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5187
  • 1.3216
  • 1.5101
  • 1.2027
  • 1.4726
  • 1.2370
  • 1.2359 *

.8075

  • ee. 1084.*. 1.2766
  • 1. 1125.*. 1. 3923.*.1. 1345
  • 1.3439
  • 1.3340
  • 2.0221..*.
  • 1

.ee.....

..eeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.1995
  • 1.4940-* 1.3066
  • 1.4737
  • 1.2584
  • 1.3141
  • 1.0571
  • 1202..*. 1. 2830..*. 1. 1339..*.1. 3229.*. 1 2607..*.1 5566.*. -
  • 1.3934
  • 1 eeeeeeeeeee.

13

  • 1.3944
  • 1.3045
  • 1.3934
  • 1.2370
  • 1.3163
  • 1.1685 *

.7315

  • e.1. 1943.*.1 2770.*. 1 1977..*.1 3438
  • 1.2592
  • 1.4125
  • 2.2310 *

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

1.3216

  • 1.1984
  • 1.2359
  • 1.0581 *

.7401

  • 14
  • 1.2520 *
  • 1. 3199..*.1. 2518..*.1. 3778'* 1.3340..*. 1. 5544.*.2. 2058.*

e.

.eeeeee.

15

  • 1.0924 *

.8332

  • 1.0292 *

.8065

  • F-SUB-Q e.1 4977..*. 1. 9626.*.1. 5878.*.2. 0240
  • N-8UB-Q eeeeen AT 1004 POWER, 415 EFPD, THIS Is LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) i H

Q F

E D

C B

A seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7700 *

.6951 *

.9050 *

.7208

  • 8504
  • 1.0089 *

.9189 *

.7518 *

. 2. 1172..*.2. 3506.*.1. 8090.*. 2. 2686

  • 1.9081
  • 1.6047
  • 1.7579
  • 2.1299
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9*

.6951 *

.8450 *

.7197 *

.9018 *

.7294 *

.9371 *

.9682 *

.6148 *

  • 2.3506
  • 1.9332
  • 2.2734
  • 1.8137
  • 2.2267..*. 1. 7307.e*ee1.6687
  • 2.6022 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeee 10 *

.9050 *

.7197 *

.9061 *

.7186

  • 9125
  • 1.0067 *

.8643 *

.4487

  • e.1. 8 0 9 0. *. 2. 2 7 3 4. *.1 8 0 6 0.. *. 2 2 710.. *. 1. 7 811. *. 1. 6118 8 ' 1. 8 6 5 6. *. 3. 5 42 6...*

11 *

.7208 *

.9018 *

.7186 *

.8493 *

.7101 *

.8814 *

.8729 *

.5773 *

  • 2. 2686.*. 1. 8137.*. 2. 2686.*. 1. 9113..*eee.2791
  • 1.8365
  • 1.8432
  • 2.7607 *-

2 e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12 *

.8504 *

.7304 *

.9136 *.7111 *

.8771 *

.9286 *

.7508 *

  • 1.9081
  • 2.2219
  • 1.7781
  • 2.278 9.. *. 1. 8 4 4 3.. *. 1. 7 3 9 4.. *.2.

14 0 6. *.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.0089 *

.9382

  • 1.0078 *.8825 *

.9296 *

.8257 *

.5280

  • e. 3..,6 0 47.. *.1.7 2 9 2.. *. 1. 610 6.. *.1.

8 3 4 9.. *e e e e.7 3 67

  • 1. 9 527 ^
  • 3. 0 2 6 4
  • 1 eeeeeeeeeeeeeeeeeeeeeee.

14 *

.9189 *

.9671 *

.8643 *

,8729 *

.7529 *

.5344 *

  • e 7579..*.1. 6688..*. 1. 8656
  • 1.8432
  • 2.1364
  • 2.9884 *
  • 1

...eeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.7518 *

.6148 * -.4487 *

.5773

  • 2. 1299 2.6022
  • 3.5432
  • 2.7642
  • M-SUB-Q' ee

.eeeeeeeeee***eeeeeeeeeeeeeeee

~

4 l

Catawba 2 Cycle 7 Core Operating Limits Report Page 23 of 144 Appendit A TABLE 1 (CONTINUED)

NORMAL OPERATION F-SUB-Q & H-SUB-Q VALUES (F-SUB-Q OP KARGIN)

AT 75% POWER, 4 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 m TOP OF CORE. LEVEL 1 m BOTTOM) i

....H...

.... 0.........F........B.........D.........C.........B.........A...

.e 8*

.3288 *

.2710 *

.5473

  • 3438
  • 5633 *

.6662 *

.6276 *

.4884 *

. 3 3 3 4 0. *. 4. 7 0 6 4. *. 2. 5 2 8 6. +. 4 0 4 57.. *. 2. 4. 6 9 2. *.2.

0. 8 9 2.. *. 2. 2 2 62. *.2.

8 4 2 9.. *.

ee.

9*

.2710 *

.4852 *

.3277

  • 5783
  • 3748 *

.6287 *

.6394 *

.4263 *

  • 4 7064.*.2. 78.65..*.4 1659.*.2. 3427
  • 3.6272
  • 2 2098
  • 2.1577
  • 3. 2.516..*

i eeeeeeeeeeeeeeee eeeeeeeeeeeee.

1 10 *

.5473 *

.3277 *

.5591

  • 3406
  • 5923 *

.6276 *

.5773 *

.2356 *

. 2. 5286..*.4 1577..*.2. 4016.*. 3. 9031.*. 2. 2744.*.2. 1229.*. 2. 3453..*.5. 7013.*

i 11 *

.3438 *

.5826 *

.3416

  • 5216
  • 3245 *

.5366 *-.5184 *

.3781 *

  • 4. 0457..*ee. 3349.*.3. 8887
  • 2.3*532
  • 3.6147
  • 2.2573
  • 2.4071
  • 3 4432..*.

2 e.

    • eeeeeee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.e..

12 *

.5633 *

.3770 *

.5944

  • 3256
  • 4487 *

.4520 *

.4273

  • j

. 2. 4692..*. 3. 6085.*. 2. 2646.*. 3. 602.4.*. 2 2168.*.2. 2597..*.2. 6800.*.

e....

13 *

.6662 *

.6297 *

.6297

  • 5387
  • 4541 *

.3823 *

.2731 *

  • 2. 0892..*.2. 2052..*.2. 1165
  • 2.2500
  • 2.2524
  • 2.4491
  • 3.90.*31 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee ee.

14 *

.6276 *

.6405 *

.5783 *- 5205

  • 4295'*..2785 *'
  • 2. 2 2 6 2.. *. 2. 157 7...*. 2. 3 4 01. *. 2. e. 3 9 8 8. *. 2. 6. 6 9 8. *. 3. 8 2 5 0.. *.

)

15 *

.4884 *

.4263 *

.2367

  • 3791

5

  • 2. 8429.*.3. 2516.e*eee.6859
  • 3.4319..* M-SUB-Q e

eeeeeeeee...

AT 75% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LBVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

H G

F E

D C

B A

eeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.4616 *

.7958 *

.8311

  • 9371
  • 8236 *

.9232 *

.9468 *

.8011 *

. 2. 8 9 8 6.. *. 2 0 9 0 9.

  • e * *. 0 9 6 0
  • 1. 8 719
  • 2.13 6 0
  • 1. 8 9 9 6
  • 1. 8 571
  • 2.18 31 *

.2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

9 *

.7958 *

.7176 *

.9039

  • 8675
  • 9682 *

.9543 *

.9318 *

.6447

  • l

. 2. 0909..*.2. 3549..*.1. 9123..*. 1. 9984..*.1 7678..*. 1. 8190..*.1 8598.*. 2. 7094.*

10

  • 8311 *

.9050 *

.8664

  • 9221
  • 8889 *

.8900 *

.8771 *

.7015 *

  • 2. 0 9 6 0.. *.1.9 0 9 4.. *.1.

3 7 5 4. *.1.815 2. *.1.0 8 8 4.

  • e e 910 9.. *. 1. e. 9 3 2 4
  • 2. 416 8. *e 1

e ee..

11 *

.9371 *

.8707 *

.9253

  • 7593
  • 8771 *

.8129 *

.8043 *

.5826 *

  • 1.4407
  • 1.8126
  • 2.0892
  • 1.7751
  • 1.905 1

I

    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.2e*eeee.9440
  • 2.8316 *

.+1 8719 eeeeeeeeeeeeeee i

12 *

.8236 *

.9768 *

.8932

  • 8804
  • 6201 *

.7069 *

.6822

  • e.2. 13 6 0.. *.1.7 6 0 5. *. 1. 0 815..*..~ 1. 7 6 9 0
  • 1.8544
  • 1.8747
  • 2.1360 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeen.

13 *

.9232 *

.9564 *

.8932

  • 8161 *

.7101 *

.6126 *

.4180 *

  • 1. 8996
  • 1.8139
  • 1.9024
  • 1.8982
  • 1.8692
  • 1.9382
  • 3.2417
  • e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14 *

.9468 *

.9339 *

.8793

  • 0065 *

.6865 *

.4295

  • e.1. 8 571.. *.1.8 5 71. *. 1. 9 2 8 0. *.1 9 3 67.. *. 2. 12 5 4. *. 3. 16 5 9. *.

15 *

.8011 *

.6447 *

.7026

  • 58 48
  • 2.1831
  • 2.e.7122
  • 2. 4123
  • 2.8192
  • N-8UB-Q eeeeeeeeee.

eeeee..

.eeeeeeeeeeeee m.

,w

,9 y

e.=w

Catawha 2 Cycle 7 Core Operating Limits Report Page 29 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q MLUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER,

& EPPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON)

H B

A

.............G........F.........B.........D.........C......eeeeeeeeeeeeeeee ee 8 *

.5955

  • 1.0624
  • 1.0978
  • 1.2231
  • 1.0357
  • 1.1395
  • 1.1556
  • 1.0078
  • 1 e.2. 5 0 62.. *.1.7 5 21
  • 1. 7 6 6 8
  • 1. 5 9 5 3...*.1.

8 7 7 5.. *. 1. 7 0. 9 6. *. 1 6 3 9 6.

  • e e e. 92 6 9 *

.. eeeeeeeeeeeeeeee..

eeeee.

9

  • 1.0624 *

.9361

  • 1.2006
  • 1.1353
  • 1.2220
  • 1.1706
  • 1.1578 *-.7808 *
  • 1.7 521
  • 2. 0 0 57
  • 1. 6 0 37
  • 1. 7 021. e *e e e e. 5 537
  • 1. 6371
  • 1. 6 6 6 0
  • 2. 47 67
  • 1
  • eeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.0978
  • 1.2017
  • 1.1449
  • 1.2081
  • 1.1299
  • 1.1310
  • 1.0881 *

.9018

  • 1.6018
  • 1.6690
  • 1.. ee*eee.6559
  • 1.6751 + 1.7366
  • 2.0961
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 5476
  • 1.7668
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.2231
  • 1.1406
  • 1.2134 *

.9810

  • 1.1417
  • 1.0282
  • 1.0282 *

.7411

  • 1.7074
  • 2.4921
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.212
  • 1.e.5406
  • 1.6885 *
  • 1.5953
  • 1.6958
  • 1.5450
  • 1.8.....

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.0357
  • 1.2284
  • 1.1363
  • 1.1449 *

.6032 *

.9125 *

.8664 *

  • ee 8775..*. 1 5467..*.1 6489..*.1. 5398.*. 1 6294.*.1. 6401.*. 1 9041.*
  • 1 13
  • 1.1395
  • 1.1760
  • 1.1363
  • 1.0324 *

.9168 *

.7893 *

.5184 *

  • 1.7096
  • 1.6303
  • 1.6670
  • 1.6833
  • 1.6342
  • 1.7160
  • 2.9726
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.1556
  • 1.1588
  • 1.0913
  • 1.0324 *

.8707 *

.5312

  • e.1. 6 8 9 6. *.1 6 62 9.. *. 1. 7 3 2 2.. *.1.

7 011

  • 1. 8 9 3 6
  • 2. 8 9 6 9
  • eeeeeeeeeeeeeee. eee.

15

  • 1.0078 *

.7808 *

.9039 *

.7433

  • 1. 9 2 6 9
  • 2. 47 9 0
  • 2. 0 913
  • 2. 4 8 31.
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee....

AT 75% POWER, 4 RFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen B*

.7144

  • 1.2723
  • 1.2991
  • 1.4394
  • 1.1995
  • 1.3184
  • 1.3238
  • 1.1610 *
  • 2.2947
  • 1.5852
  • 1.6034
  • 1.4544
  • 1.7289
  • 1.5852
  • 1.5798
  • 1.7922
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.2723
  • 1.1053
  • 1.4276
  • 1.3355
  • 1.4319
  • 1.3559
  • 1.3388 *

.4879

  • 2 e.1. 5852..*. 1. 8251.*. 1. 4506.*. 1. 5551
  • 1 4297..*.1 5203.*.1. 54.56.*.eee.3198
  • eeeen........ ee.

eeeeen 10

  • 1.2991
  • 1.4287
  • 1.3537
  • 1.4298
  • 1.3270
  • 1.3238
  • 1.2595
  • 1.0485 *
  • 1.6034 *-1.4491
  • 1.5211
  • 1 4116.*.1. 5269.*. 1.5396
  • 1.6174
  • 1.9400
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeee....

eeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.4394
  • 1.3409
  • 1.4373
  • 1.1599
  • 1.3655 ' 1.2156
  • 1.2156 *

.8611 *

  • 1.4544
  • 1.5499
  • 1.4088
  • 1.6723
  • 1.4116
  • 1.5620
  • 1.5762
  • 2.3229
  • eneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.1995
  • 1.4394
  • 1.3345
  • 1.3698 *

.9746

  • 1.1053
  • 1.0303
  • e.1. 72 89.*. 1. 42 2 4
  • 1. 52 03..*.1 408 0.*. 1.e. 5 087
  • 1. 5112
  • 1.77 06
  • eeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3184 *'1.3623
  • 1.3313
  • 1.2209
  • 1.1106 *

.9693

  • 6148 *
  • 1.5852
  • 1.5137
  • 1.5337
  • 1.5568
  • 1.5055
  • 1.5906
  • 2.7922
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.3238
  • 1.3409
  • 1.2627
  • 1.2209
  • 1.0367 *

.6308 *

  • 1.5798
  • 1.5430
  • 1.6127
  • 1.5700
  • 1.7605
  • 2.7205
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**ee 15
  • 1.1610 *

.8879

  • 1.0517 *

.8643

  • 2.3217
  • 1.93 55
  • 2.3132
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

l e

~..

4

' Catawba'2 Cycle 7 Core Operating Liraits Report Page 30 of 144 Appendix A 1

TABLE 1 (CONTINUED) l J

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION l

1 AT 75% POWER, 4 EFPD, 'THIS IS LEVEL 14 OF 38,

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

]

H F

H D

C B

A eeeeeeeeeeee.G eeeeeeeeeeeeeeeeeeeeeee..eeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeee 8*

.8472

  • 1.4084
  • 1.4159
  • 1.5637
  • 1.2895
  • 1.4234
  • 1.4169
  • 1.2424
  • a
  • 1.7396
  • 1.5959
  • 1.6004
  • 1.8176
  • i
  • 2.3032
  • 1.5825
  • 1.6059
  • 1.4546 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

9

  • 1.4084
  • 1.2081
  • 1.5626
  • 1.4501
  • 1.5658
  • 1.4641
  • 1.4437 *

.9446

  • j eeeeeeeeeeeeeeeeeeeeeeee e.2. 3559..*

1.5361

  • 1.5590
  • ee. 5825.* 1.8277.*. 1. 4457..*. 1. 5.624..*.1.4340 *
  • 1.... eeeeee

+

10

  • 1.4159
  • 1.5647
  • 1.4737
  • 1.5647
  • 1.4480
  • 1.4426
  • 1.3591'* 1.1299
  • 3 4
  • 1.9669
  • e.1 6059..*.1. 4442..*.1 5270.*. 1. 4125.*.1. 5378
  • 1.5453
  • 1.6 9
    • eeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5637
  • 1.4544
  • 1.5722
  • 1.2745
  • 1.5230
  • 1.3495
  • 1.3420 *

.9286

  • f
  • 1.4546
  • 1.5564
  • 1.4090
  • 1.6777
  • 1.4132
  • 1.5772
  • 1.5896
  • 2.3652
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2895
  • 1.5733
  • 1.4555
  • 1.5283
  • 1.1770
  • 1.2756
  • 1.1524
  • 1 5204 *. 1. 7968.*

e.1. 7 3 9 6. *. 1. 4 2 6 0. *.1.

5 311.. *.1.4 0 9 0. *.1. 5 2 37. *..

.e e

.. e 13

  • 1.4234
  • 1.4705
  • 1.4501
  • 1.3548
  • 1.2831
  • 1.1727 *

.6960 *

  • 1.5959
  • 1.5286..*. 1. 5386.*.1 5702..*.1. 5147.*.1. 610.5.*. 2. 8396..*

eeeeeeeeeeeee

-14

  • 1.4169
  • 1.4459
  • 1.3634
  • 1.3484
  • 1.1599 *

.7122 *

. 1 600.4.*.1 5555.*. 1. 6337..*. 1. 5825

  • 1.7855
  • 2.7634 *

.eeeeeeeeeeeeeeeeeeeee.

15

  • 1.2424 *

.9436

  • 1.1331 *

.9328

  • 1. 817 6.*. 2. 3 57 9. *.1.9 614.*.2. 3 5 3 4.*.M-EUB-Q e.

AT 75% POWER, 4 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 s BOTTOM)

H G

F D

B A

e e e e e e e e e e e e e e e e e e e e e e e e e e e e e..E.... e e e e e e e e e e n e

.C. e e e e e e e e e e e e e e.

eeeeeeeee 8

  • 1.0335
  • 1.5712
  • 1.5637
  • 1.7179
  • 1.4116
  • 1.5594
  • 1.5487 *-1.3570
  • eee 302.1.*. 1. 5826.*.1. 6056.*. 1. 4564.*.1. 7362..*.1. 6020.*. 1 6074
  • 1.8242 *
  • 2

. eeeeeeeeeeeeee.

9

  • 1.5712
  • 1.3388
  • 1.7265
  • 1.6001
  • 1.7307
  • 1.6108
  • 1.5829
  • 1.0282
  • eeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 5417
  • 1. 631.eeeeeeeeeeeee*eeee.3 5 6 2
  • 1.5826
  • 1.8208
  • 1.4454
  • 1.5636
  • 1.4338
  • eeeeee it
  • 1.5637
  • 1.7286
  • 1.6279
  • 1.7382 + 1.6044
  • 1.5936
  • 1.4962
  • 1.2402 *
  • 1. 6 0 5 6..*. 1. 4 4 3 2..*.
1. 5 2 8 6.*e e. 414 0.*. e e e. 5 4 0 9
  • 1. 5 47 6.*. e e e. 6 471.*. 1. 9 7 5 0.
  • 1 1

1...

eeeeeeeeeeee.

eee.

e.

11

  • 1.7179
  • 1.6033
  • 1.7393
  • 1.4244'* 1.7168
  • 1.5230
  • 1.5058
  • 1.0228
  • eeeeeeeeeeeeeeeeeee.1. 4099.*. 1.6730
  • 1.4140
  • 1.5817
  • 1.5931
  • 2.3818 *
  • 1.4564
  • 1.5577 *

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen "12

  • 1.4116
  • 1.7393
  • 1.6129
  • 1.7222
  • 1.5208
  • 1.5208
  • 1.3130
  • eeeeeeeeeeeeeeeeeee.1. 5335
  • 1.4099
  • 1.529.4.*.1. 5221.*. 1. 8047..*.
  • 1.7362
  • 1.4267 *

.eeeeeeeeeeeeeeeeeen 13

  • 1.5594
  • 1.6163
  • 1.6022
  • 1.5294
  • 1.5272
  • 1.4223 *

.7990 *

  • 1.6020..*.ee 5335
  • 1.5409
  • 1.5748 **e**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8467
  • 1 1.5165
  • 1.6147
  • 2 eeeee.

...ee.

14

  • 1.5487
  • 1.5862
  • 1.5015
  • 1.5133
  • 1.3216 *..8215
  • 2.7708 *

. 1.6074

  • 1.5602
  • 1.6415
  • 1. 5861
  • 1.7934
  • j eeeeeeeeeeeeeeeee.eeeeeee..

eeeeeeeeeeeeee*eeeeeeeen 15

  • 1.3570
  • 1.0271 *.1.2434
  • 1.0282

1

. 1. 8242.*. 2.3603.*.eee.9709eee... 2 3719..*. M-SUB-Q l

P e

WQ

^

V 1'

Y

Catawba 2 Cycle 7 Core Operating Limits Report Page 31 of 144 Appendix A F

TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER, 4 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H

'Q

F E

D C

B-A-

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1042
  • 1.6547
  • 1.6376
  • 1.7993
  • 1.4705 a 1.6290
  • 1.6151
  • 1.4137 *

. 2. 4234.*.1. 6542..*.1.6812

  • 1.5233.*. 1.e.8269
  • 1.6782
  • 1.6861
  • 1.9064 *

.... eeeeeeeeeee...

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

  • 1.6568
  • 1.0667
  • 9
  • 1.6547
  • 1.4030
  • 1.0143
  • 1.6761
  • 1.8218
  • 1.6858
  • 1.6542
  • 7 2.4804
  • e e e e e e e e e e.1.

9.13 5

  • 1. 5106
  • 1. 63 9 2..*.1. 49 9 6
  • 1. 619 0
  • 1. 63 3
  • eeeeeeeeeeeeeeeee

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6376
  • 1.8164
  • 1.7093
  • 1.8357
  • 1.6879
  • 1.6761
  • 1.5658
  • 1.2948 *
  • 1.6812
  • 74*

e e e e e s e. e e.1. 50 9 2

  • 1. 6 037 + 1. 48 0 4.*.1 6181
  • 1. 6217
  • 1.7 3 05
  • 2. 0 3

...e eeeeeeeeeeeee.......eeeeeeeeeeeeeeeeeeeeee.eeeeeeee 11

  • 1.7993
  • 1.6804
  • 1.8357
  • 1.5080
  • 1.8261
  • 1.6183
  • 1.5969
  • 1.0609 *
  • 1.5233 *'1.6346
  • 1.4759
  • 1 1.4812
  • 1.6628
  • 1.6724
  • 2.5094 8'

eeeeeeeeeeeeeeeeeeeeeeeeeeeee. 7610 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12

  • 1.4705
  • 1.8314
  • 1.6965
  • 1.8325
  • 1.6590
  • 1.6579
  • 1.4009
  • eee 8269..*.1. 4919.*eee.6100..*. 1. 4766
  • 1.6100
  • 1.5984
  • 1.9002 *
  • 1 1

n..

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee is

  • 1.6290
  • 1.6943
  • 1.6858
  • 1.6258
  • 1.6643
  • 1.5540 *

.8579 *

  • 1.6782
  • 1.6109
  • 1.6145
  • 1.6552
  • 1.5913.*.1.6990
  • 3.0118
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. eeeeeeeeeeeeeeeee l

14

  • 1.6151
  • 1.6600
  • 1.5712
  • 1.6054
  • 1.4105 *

.8814

  • l 1.6861
  • 1.6346
  • 1.7254
  • 1.6647
  • 1.8878
  • 2.S307
  • eeeeeeeeeeeeeeee. eeeeeeeeeeeeeeeee.eeeeeeee.seeeeeeeee 15
  • 1. 4137
  • 1.0667
  • 1.29 91
  • 1.0742
  • 2.483 0
  • 2.0675
  • 2.4985
  • M-SUB-C.

I eeeeeeeee**eeeeeeeeeeeeeeeeeeeeee AT 75% FOWER, 4 EFPD,. THIS IS LEVEL 11 OF 19

(

(LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

.ee.H..ee.....G........F.eeee....E.........D.

......C.........B.........A...

1.1256

  • 1.6922
  • 1.6675
  • 1.8368
  • 1.4940
  • 1.6611
  • 1.6440
  • 1.4384
  • 8 *

. 2. 5 8 82.. *.1 7. 42. 0. *.1777 4..*.1 6055. *e e 9 4 9 5

  • 1 7 67 6
  • 1.77. 63. *.2.

0 03 0 *

  • ~

1 eee.e.e.

.eee...ee eeeeee l

9

  • 1.6922
  • 1.4276
  • 1.8560
  • 1.7072
  • 1.8646
  • 1.7179
  • 1.6911
  • 1.0817 *
  • 1 7 4 2 0.*.2. 0 4 31.*. 1 5 9 2 2.. *. 1. 73 57..*. 1. 5 817.
  • 1. 7141.*. e e e.7 2 6 4
  • 2. 6 3 8 4
  • 1 eee

..ee eeeeeeeeeeeeee.

10

  • 1.6675
  • 1.8582
  • 1.7436
  • 1.8828
  • 1.7232
  • 1.7157
  • 1.5958
  • 1.3195
  • l 1.7774
  • 1.5905
  • 1.6990
  • 1.5629
  • 1.7151
  • 1.7131
  • 1.8327
  • 2.1897
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.8368
  • 1.7115
  • 1.8871
  • 1.5465
  • 1.8796
  • 1.6622
  • 1.6418
  • 1.0881 *
  • 1.6055
  • 1,7305
  • 1.5587
  • 1.88 1
  • 1.7698
  • 2.6644
  • e e e e e e e e e e ee.e eeeee ee e e e e e e ee ee e.39.*.1. 56.38..*.e ee.7644 eeeeeeeeeeee***e eeeeeen 12
  • 1.4940
  • 1.8742
  • 1.7329
  • 1.8860
  • 1.7136
  • 1.7190
  • 1.4416
  • 1.9495
  • 1.5731
  • 1.7060
  • 1.5587
  • 1.7111
  • 1.6930
  • 2.0184
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

.8836

  • 13
  • 1.6611
  • 1.7275
  • 1.7254
  • 1.6708
  • 1.7265
  • 1.6108
  • 1.7676
  • 1.7050
  • 1.7040
  • 1.7569
  • 1.6861
  • 1.8052
  • 3.2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.337
  • eeen.

14

  • 1.6440
  • 1.6943
  • 1.6022
  • 1.6504
  • 1.4523 *

.9082 *

  • 1. 7763.*eee.7223.* 1.8269
  • 1.7611..*.2. 0043..*.3. 1481
  • 1

. e ee... ee..eeeeeee.

..e..

j 15

  • 1.4304
  • 1.0006
  • 1.3238
  • 1.0935
  • 2. 0030'* 2. 6409.*. 2. 1831
  • 2. 6522..* M-SUB-Q t

.e..

eee e

l

l Catawba 2 Cycle 7 Core Operating Limits Report Page 32 of 144 Appendix A.

TABLE 1 (CONTINUED)

F-SUB-Q E M-8V8-Q VALUES (F-SUS-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER, 4 EFPD.

THIS IS LEVEL 10 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

I

....H........ 0.........F.........E........D.........C.........B.........A.....e 8*

1.1545

  • 1.7425
  • 1.7168
  • 1.8935
  • 1.5369
  • 1.7123
  • 1.6965
  • 1.4855
  • 1
  • 2 1

1

... 6 315...*.1.7 4 8 3. *e e e e. 7 818

  • 1. 610 9. *.1.

9 7 41..*.1 7 8 0.) e *e e e e. 8 0 07

  • 2. 0 3 6 9..
  • 1 eeeeeeeeee...

eeeeeeeee.

9

  • 1.7425
  • 1.4683
  • 1.9149
  • 1.7597
  • 1.9257 *.1.7725
  • 1.7468
  • 1.1138
  • l
  • 1.7483
  • 2.0663
  • 1.5957
  • 1.7410
  • 1.5878'* 1.7295
  • 1.7483
  • 2.7186
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.7168
  • 1.9171
  • 1.7971
  • 1.9471
  • 1.7789
  • 1.7725
  • 1.6483
  • 1.3612 *

. 1. 7 818.*. 1. 5 9..* 0*..1 7050.*. 1. 5714.*..1 7233..*.1. 726.4.*. 1. 8634

  • 2e.2477 *

...e eeeeen 11

  • 1.8935
  • 1.7639
  • 1.9535
  • 1.5990
  • 1.9449
  • 1.7211
  • 1.7018
  • 1.1213 *

. 1. 6109.*. 1. 7368.*. 1. 5672..*. 1. 9073

  • 1.5740
  • 1.7884
  • 1.8052
  • 2. 7455..*.

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.5369
  • 1.9364
  • 1.7886
  • 1.9534
  • 1.7768
  • 1.7875 a 1.4951 *'
  • 1. 9 7 41
  • e e e. 57 91
  • 1.7141
  • 1. 5 6 8 0.*.
1. 7 3 47.. *.1.7 213...*.2.0 616.*

1 eeeeeeme e eeeeeeeeeeeeeeeeeee..

13

  • 1.7179
  • 1.7821
  • 1.7832
  • 1.7297
  • 1.7961
  • 1.6761 *

.9157

  • 1.7202
  • 1.7161
  • 1.7796
  • 1.7131
  • 1.6408
  • 3.3640 *
  • 1.7807
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.6965
  • 1.7500
  • 1.6536
  • 1.7104
  • 1.5058 *

.9403 *

1. 7441..*. 1 8562..*. 1.7951 *'2.0470
  • 3.2759 *
  • 1.8007
  • semeeeeeeeeeeeeeeeeeeeeee.

eeee**ee...

15

  • 1.4855
  • 1.1128
  • 1.3 655
  • 1.1267
  • 2. 0369..*. 2. 7211'* 2 2407..*. 2. 7299.*e M-SUB-Q

..a ee AT 75% POWER, 4 EFPD, THIS 18 LEVEL 9 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 m BOTTOM)

E G

E C

B A

eeeeeeeeeeeeeeeeee...F...eeeeeeeeeeeee..D... eeeeeeeeeeeeeeeeeeeeeeeeeeene 8* 1.1256

  • 1.7125
  • 1.6825
  • 1.8646
  • 1.5048
  • 1.6868
  • 1.6686 *.1.4619
  • e.. 6669... 1. 7 5 2 6.. *e e e e. 7 9 0 6. *.1.

6 07 3.. *. 1. 9 8 9 2. *. 1. 77 41.. *.1.

7 8 51..*. 2. 0.141.

  • 1
  • 2 ene..

1.7125

  • 1.4351
  • 1.0871
  • 1.7254
  • 1.9000
  • 1.7414
  • 1.7222
  • 1.0913
  • 9
  • 56
  • 1.7494..*. 1. 5870.*. 1. 7347..*.1. 7410..*.2. 7044.*.
  • 1.7526
  • 2.0914
  • 1.59

.eeeeee.

eeeeeeeeeeeeeeeeeeeeen..

10

  • 1.6825
  • 1.8892
  • 1.7618
  • 1.9224
  • 1.7468
  • 1.7500
  • 1.6194
  • 1.3388 *
  • 1 7906.*. 1. 5948.*. 1. 7.141..*.1 5706.*. 1 7305.*. 1. 7254.*.1. 8682..*.2. 2494.*.
  • ee 11
  • 1.8346
  • 1.7307
  • 1.9289
  • 1.5712
  • 1.9203
  • 1.6933
  • 1.6793
  • 1.0978
  • e.1. 6 07 3.. *. 1. 7 4 52.. *.1.

5 6 5 5. *.1.9 2 2. 9. *.1.572 3. *. 1 7 9 4 0. *. 1. 8 0 52.. *. 2. 7 612..

  • 12
  • 1.5048
  • 1.9107
  • 1.7575
  • 1.9278
  • 1.7479
  • 1.7671
  • 1.4716 *
  • 1.9892
  • 1.5783
  • 1.720*
  • 1.5663.*. 1. 7410..*. 1. 7202..*. 2.

0.V.d.0..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeees 93e 13

  • 1.6868
  • 1.7511
  • 1.7597
  • 1.7018
  • 1.7757
  • 1.6536 *

.8986

  • 1.7741
  • 1.7243
  • 1.7141
  • 1.78..51. *. 1. 7121. *.1. 8 4 3 2.. *. 3. 410 0.. *.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.6686
  • 1.7154
  • 1.6258
  • 1.6879
  • 1.4823 *

.9232 *

  • 1.7853..*. 1 7368..*.1. 8610.*.1. 7951.*.2. 0528.*. 3. 3160.*.

eeeeee.

ne..

15

  • 1.4619
  • 1.0903
  • 1.5430
  • 1.1031
  • F-sUB-Q e.2. 0141.*.2. 7 0.6 9. *.2.2 42 4.*. 2. e.7 4 5 5. *. M-SUB-Q e...

i

i l

Catawba 2 Cycle 7 Core Operating Limits Report Page 33 of144 Appendix A l

TABLE 1 (CONTINUED)

F-SUB-Q ts M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORtiAL OPERATION AT 75% POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eeeeeeeeeeeeeeeeeeeeeeeeeeseeeeese 8* 1.1320

  • 1.7297
  • 1.7018
  • 1.8871
  • 1.5208
  • 1.7082
  • 1.6943
  • 1.4865
  • e.2. 5811..*.1 6890.*.1. 7233..*.1. 5355
  • 1.8977..*. 1. 6851.*.1. 6890.*.1. 8939..*e

.....e**e 1.7297

  • 1.4480
  • 1.9107
  • 1.7457
  • 1.9257
  • 1.7671
  • 1.7489
  • 1.1053
  • 9
  • e 1.6890
  • 2.0155
  • 1. 5355
  • 1. 6831.*.1 5258.*. 1. 6609..* 1 6523
  • 2 5492..*.

eeeeeeeeeeeeeeee..

ee.....

ee..

e..eeeeeee..

[

10

  • 1.7018
  • 1.9128
  • 1.7832
  • 1.9492
  • 1.7704
  • 1.7768
  • 1.6440
  • 1.3591 *
  • 1.6647
  • 1.6561
  • 1.7917
  • 2.1300 *
  • 1 7233..*.1. 53.39.*.1. 6514.*.1 5122 l

e..

......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeee.

11

  • 1.8871
  • 1.7511
  • 1.9567
  • 1.5915
  • 1.9481
  • 1.7190
  • 1.7072
  • 1.1117
  • eeeeeeeeeeeeeeee... 1.5074
  • 1.8538
  • 1.5146
  • 1.7295
  • 1.7347
  • 2.6474 *
  • 1.5355
  • 1.6782 *.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.5208
  • 1.9364
  • 1.7811
  • 1.9556
  • 1.7736
  • 1.7982
  • 1.4951 *
  • 1.8977
  • 1.5169.*. 1. 6552
  • 1.5090
  • 1.6841
  • 1.6609
  • 1.9947
  • eeeeeeeeeeeeeee.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.7082
  • 1.7768
  • 1.7864
  • 1.7275
  • 1.8068
  • 1.6836 *

.9104 *

  • 1.6851
  • 1.6523
  • 1.6457
  • 1.7202
  • 1.6523
  • 1.7818
  • 3.3046
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*e 14
  • 1.6943
  • 1.7532
  • 1.6504
  • 1.7168
  • 1.5069 *

.9361

  • e 1 6890..*.1. 6486.*. 1. 7851.*. 1. 7254
  • 1.9796
  • 3.2128
  • e ee.

eeeeeeeeeeeeeeeeeeeeeeee 15

  • 1.4865
  • 1.1053
  • 1.3634
  • 1.1181
  • 1.8939
  • 2.551 eeeeeeeeeeeeeee.5..*.2. 1237
  • 2.6353
  • M-SUB-Q l

..eeeeeeeeeeee.

AT 75% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) 0 F

E D

C B

A

  • ee.H.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e.

8

  • 1.0978
  • 1.6890
  • 1.6611
  • 1.8496
  • 1.4844
  • 1.6740
  • 1.6622
  • 1.4598
  • een 5028.*. 1 6064 *...... 1.e.6299..*.1. 4521
  • 1.7995
  • 1.5905
  • 1.5966
  • 1.7906 *
  • 2 e

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6890
  • 1.4094
  • 1.0710
  • 1.7061
  • 1.8882
  • 1.7307
  • 1.7179
  • 1.0817
  • eeee.. 4 *.1. 9178.*eeee.4550
  • 1. 5966
  • 1. 4463.e*. 1. 5680 *..... 1. 5553.*. 2 4190 *
  • 1.606 1

eeeeee.

e

..e e.

10

  • 1.6611
  • 1.8742
  • 1.7414
  • 1.9128
  • 1.7339
  • 1.7457
  • 1.6108
  • 1.3323
  • l e.. 6299..*. 1. 4528.*ee. 5766.*. 1. 4470
  • 1.5905
  • 1.5672
  • 1 6881
  • 2.0030
  • 1...

1 eeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeee.

11

  • 1.8496
  • 1.7125
  • 1.9203
  • 1.5572
  • 1.9117
  • 1.6847
  • 1.6772
  • 1.0860 *
  • eee 4521.*. 1. 5922
  • 1.4391
  • 1.7962
  • 1.4632
  • 1.6782
  • 1 476
  • 2.5028
  • 1

.ee

.eeeeeeeeeeeee ee eee ens ee eeee e eeeeeee e eee eeee-eeeeeeeeeeeeee 1.9000

  • 1.7447
  • 1.9192
  • 1.7372
  • 1.7671
  • 1.4651
  • 12
  • 1.4844 *
  • 1.7995
  • 1.4384
  • 1. 5809
  • 1.4572..*. 1. 6676..*. 1. 6281..*. 1. 9332..*.

eeeeeeeeeeeeeeeeeee.

.eeeeeeee.

13

  • 1.6740
  • 1.7404
  • 1.7h43
  • 1.6933
  • 1.7757
  • 1.6526 *

.8889 *

  • 1 5 9 0 5. *.1. 5 5 9 5.*. e e e. 5 57 9
  • 1. 6 6 8 6
  • 1. 6 2 0 8. *. 1. 7 5 0. 5.*.
3. 2 0 9 2. *.

1 e.

eeeeeeeeee........

14

  • 1.6622
  • 1.7222
  • 1.6172
  • 1.6868
  • 1.4769 *

.9146 *

  • 1.5966
  • 1.5520
  • 1.6822
  • 1.6590
  • 1.9191
  • 3.1224
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 15

  • 1.4598
  • 1.0806
  • 1.3366
  • 1.0924

~

l

  • 1.7906
  • 2.4210
  • 1.9974
  • 2.4899
  • M-SUB-Q j

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

I l

l l

Catawba 2 Cycle 7 Core Operating Limits Report Page 34 of 144 Appendix A i

TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUS-Q OP KARGIN) - NORMAL OPEi TION 1

AT 75% POWER, 4 BFPD.

THIS IS LEVEL 6 OF 18 (LEVEL 18 m TCP OF CORE, LEVEL 1 m BOTTOM)

......................F.........B.........D........C.........B.........A......

H-G 1.0314

  • 1.5990
  • 1.5690
  • 1.7564
  • 1.4019
  • 1.5915
  • 1.5787
  • 1.3869
  • 8
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 3..*. 1. 7687..*.1. 5528..... 1. 5629.*. 1. 7526.*
  • 2.4251
  • 1.5604
  • 1.5966
  • 1.419 9
  • 1.5990
  • 1.3280
  • 1.7768
  • 1.6129
  • 1.7950
  • 1.6397
  • 1.6343
  • 1.0228 *

'.*.1 5604.*.1. 8755.*. 1. 4172..*.1. 5621..*.1. 4048.*.1. 5290..*.1. 5161.* 2. 3791..*

eeeeee.

10

  • 1.5690
  • 1.7789
  • 1.6451
  • 1.8106
  • 1.6440
  • 1.6611
  • 1.5272
  • 1.2638
  • 1.5454
  • 1.5201 + 1.6429
  • 1.9528 *

. 1.e.5966

  • 1.4151
  • 1.5379.* 1.4000 eeeeeeeeeeeeeeeeeeeeee. **eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 11
  • 1.7564
  • 1.6194
  • 1.8261
  • 1.4726
  • 1.8175
  • 1.5979
  • 1.5936
  • 1.0260
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee** 4068
  • 1.6181
  • 1.6019
  • 2.4353 *
  • 1.4193
  • 1.5562
  • 1.3966
  • 1.7347
  • 1 eeeeeeeeeeeeeeeeeeeeeeee**eeeeee.

12 + 1.4019

  • 1.8057
  • 1.6536
  • 1.8261
  • 1.6461
  • 1.6815
  • 1.3880 *
  • 1.7687
  • 1.3960
  • 1.5363
  • 1.4014
  • 1.6019
  • 1.5655
  • 1.8658
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.5915
  • 1.6493
  • 1.6697
  • 1.6054
  • 1.6900
  • 1.5679 +

.8397

  • eeeeeeeeeeeeeeeeeeeeee.106 *1.5528
  • 1.5209
  • 1.5... 1 6091
  • 1.5579
  • 1.6871
  • 3.1191 *

[

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 14

  • 1.5787
  • 1.6386
  • 1.5337
  • 1.6033
  • 1.3998 *

.8632

  • e.1. 5 6 2 9. *.1.513 0
  • 1. 6 3 6 4
  • 1. 5 9 31
  • 1. 8 515.. *. 3. 0 3 07 *

.eeeeeeeeeeeeeeeeeeeeeeeeeee.. eeeeee.

I 15

  • 1.3869
  • 1.0217
  • 1.2681
  • 1.0314
  • 1.7526
  • 2.3811
  • 1.9463.*. 2. 4230.* M-SUB-Q

. eeeeeeeeeeeeeeeeeeeeee.

AT 75% POWER, 4 EFPD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8*

.9875

  • 1.5380
  • 1.5123
  • 1.6965
  • 1.3537
  • 1.5444
  • 1.5337
  • 1.3495
  • 1.6890 *

. 2.e.3425

  • 1.5130
  • 1.5495
  • 1 3747..*. 1 7131..*.1 4973.*.1. 5067
  • eeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeee.

9

  • 1.5300
  • 1.2766
  • 1.7136
  • 1.5572
  • 1.7350
  • 1.5894
  • 1.5872 *-.9917
  • e.1. 513 0. *. 1. 8 2 0 0. *. 1. 3 7 0 8.. *.1.

510 6. *. 1. 3 5 2 8. *. 1. 47 0 6. *.1.

4 5 9. 5. *.2.2 9 7 7.. *.

10

  • 1.5123 + 1.7168
  • 1.5883
  • 1.7597
  • 1.5915
  • 1.6086
  • 1.4801
  • 1.2252 *
  • 1. 5495..*. 1. 3695..*. 1. 48.50..*. 1. 3440..*. 1. 4873..*.1. 4624.*.1. 5774.*. 1. 8792. *.

11

  • 1.6965
  • 1.5637
  • 1.7661
  • 1.4244
  • 1.7586
  • 1.5476
  • 1.5465 *

.9917 *

  • 1.3747..*.1. 5043
  • 1 3396..... 6590.*. 1. 3453.*.1 5396
  • 1. 5241.*. 2. 3406
  • 1

..e e e.

1.6311

  • 1.3452 '

1.3537

  • 1.7 4 57
  • 1. 6 011
  • 1.7 6 61
  • 1. 6 v 47
  • 12
  • e.. 7131.. *.1.3 4 3 4.. *. 1. 47 81. *. 1. 3 4 0 3.. *. 1. 5 0 67
  • 1. 4 6 9 9
  • 1. 7 6 5 4 *
  • 1 eeeeeeeeeeeeeeeeeeeeeeeee.

.8118

  • 13
  • 1.5444
  • 1.5990
  • 1.6172
  • 1.5562
  • 1.6397
  • 1.3219
  • e 4 9 7 3.. *. 1. 4 6 4 6. *. 1. 4 5 2 8. *. 1. 5314. *. 1 4 6 2 4.. *.1.

57 91.. *. 2. 9 412.. *.

  • 1 e***e l

14

  • 1.5337
  • 1.5904
  • 1.4865
  • 1.5562
  • 1.3570 *

.8354 *

  • 1. 5067..*. 1. 4558.*. 1. 5714.*. 1. 5154..*. 1. 7515..*. 2.8568..*.

15

  • 1.3495 *

.9907

  • 1.2295 *

.9971

. 1 6890.*. 2. 2996..*. 1. 8731..*.2. 3292..*. M-SUB-Q ee I

i l

i I

Catawha 2 Cycle 7 Core Operating Limits Report Page 35 of 144 Appendix A TABLE 1-(CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 75% POWER, 4 EFPD, THis IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL l's BOTTOM)

H G

A e.....................F.........E.........D.........C........

B eeeeee.........

8*

.8836

  • 1.3859
  • 1.3602
  • 1.5380
  • 1.2242
  • 1.4126
  • 1.3998
  • 1.2316
  • e. 2 4 7 07.. *.1.5 8 61. *. 1. 62 81. *. 1. 4 3 2 0.. *. 1. 7 9 0 6 *.eeeeeeeeeeeeeeeeeeeee.1. 7483.*

1.5470

  • 1.5587
  • 9
  • 1.3859
  • 1.1460
  • 1.5508
  • 1.4052
  • 1.5797
  • 1.4448
  • 1.4491 *

.9018

  • 1 1.3994
  • 1.5233
  • 1.5082
  • 2.3890
  • eeeeee.1.a1.586.. 1. 9140 *eeee.4305
  • 1.5800
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3602
  • 1.5530
  • 1.4319
  • 1.5979
  • 1.4416
  • 1.4651
  • 1.3462
  • 1.1128
  • e e e e e e e... 1. 4 2 91. *.1.

5 5 3 7.. *. 1 3 9 0 6. *. 1. 5 4 3 7

  • 1. 513 0
  • 1. 6 3 4 6
  • 1. 9 4 8 9 *
  • 1.6281
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.6044
  • 1.2884
  • 1.5979
  • 1.4041
  • 1.4073 *

.8975

  • 11
  • 1.5380
  • 1.4116 *
  • 1. 4320..*.1. 5731
  • 1.3859
  • 1.7223
  • 1.3913
  • 1.5905
  • 1.5697..*.2. 4353
  • e.

..*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeee 12

  • 1.2242
  • 1.5904
  • 1.4512
  • 1.6044
  • 1.4469
  • 1.4844
  • 1.2209
  • eeeeee.... 1 3899
  • 1.5339
  • 1.3859
  • 1.5503
  • 1.5043
  • 1.8177 *
  • 1.7906 *..ee.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13
  • 1.4126
  • 1.4533
  • 1.4726
  • 1.4126
  • 1.4930
  • 1.3837 *

.7358 *

  • e e e e e e e e e e e e e e e e e e e e e e e.7...*.1.

5 817..*. 1. 4 9 7 3...*.1.

615 4.*. 3. e. 02 4 4 *

  • 1.5470
  • 1.5177
  • 1.502 ee.

eeeee.

14

  • 1.3998
  • 1.4533
  • 1.3527
  • 1.4159
  • 1.2316 * -.7572 *
  • 1. 5587..*. 1. 5043.*..l..6281..*. 1. 5604..*.1 8040.*.2 9382.*.

e.

15

  • 1.2316 *

.9007

  • 1.1171 *

.9029

  • P-sUB-Q
  • 1.7 483
  • 2.3 909
  • 1. 9 423
  • 2.4230
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.....

AT 75% POWER, 4 BFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

C B

A e e**eeeeeeeeeeeeeeeeeeeeeeeeeee.......D...eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.7840

  • 1.2263 ' 1.2070
  • 1.3773
  • 1.1033
  • 1.2884
  • 1.2820
  • 1.1192 *
1. 7141..*. 1. 7537..*.1. 52.82..*. 1. 8939.*.1. 6190..*.1 62.44..*. 1. 0373..'8
  • 2.6644
  • eeeeee.....

9

  • 1.2263
  • 1.0207
  • 1.3773
  • 1.2563
  • 1.4276
  • 1.3173
  • 1.3205 *

.8236

  • e 1.7141.*.2. 0557
  • 1. 5388.*.ee 6890.*.1. 47.59.*. 1. 5931..*.1. 5783
  • 2. 4985..*.

1

  • ee...

l 10

  • 1.2070
  • 1.3794
  • 1.2756
  • 1.4319
  • 1.3002
  • 1.3216
  • 1.2242 + 1.0025
  • I l'
  • 1. 7 5 3 7..*. 1. 5 3 63.. *.1.

6 6 57..*. 1. 47 81.. *. 1. 6 2 9 9.. *.1.

5 9 4 8. *.1.7131. *.2. 0 6 6 0. *e i

l 11

  • 1.3773
  • 1.2616
  • 1.4373
  • 1.1620
  • 1.4330
  • 1.2681
  • 1.2702 *

.0065 *

................... 1 4729.*. 1. 8177..*. 1. 4774 *............. 1. 6523.*. 2.5834 *e 1.6744 =

  • 1.5282
  • 1.6822
  • l l

12 8 1.1053

  • 1.4373
  • 1.3088
  • 1.4364
  • 1.3055 4 1.3398 8 1.1042 a

. 1. 8939.*. 1. 4661.*.1. 6199..*.1. 4721..*.1. 6299

  • 1.5809..*. 1. 9090
  • i l

..eeeeee

.eee.

13

  • 1.2884
  • 1.3227
  • 1.3302
  • 1.2756
  • 1.3462
  • 1.2520 *

.6683

  • e.1. 61. 9 0. *.1.5 8 7 0
  • 1 5 8 4 3..*.1.G. 6 47.. *.1.

5 731...*.1.

6 9 2 0..*. 3. 16 0 0. *

.e**e 14

  • 1.2820
  • 1.3238
  • 1.2295
  • 1.2788
  • 1.1138 *

.6676

  • eeeee.44.*.1. 5748.*. 1. 7070
  • 1.6429 *. 1 8939
  • 3.0694 *
  • 1.62..

eeeeeeeeeee

.. eeeeeeeeeeee.

15

  • 1.1192 *

.8225

  • 1.0057 *

.8118

  • 1.8373..*. 2. 5007..*ee 0586
  • 2. 5696..* M-sUB-Q 2

eeeee.

l i

i il'

= _ - -

F i

l Catawba 2 Cycle 7 Core Opercting Limits Report Page 36 of 144 Appendix A I

TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 75% POWER, 4 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)-

H Q

E D

C B

A eeeeeeeeeeeeeeeeeee*e.Feeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8 *

.6223 *

.9457 *

.9382

  • 1.0817.*-.8996
  • 1.0742
  • 1.0817 *

.9082

  • e. 3. 2 4 8 9. *. 2 14 9 0. *.2.

18 31. e

  • e e e. 87 9 2.- *.2.

2 4 4 2.. *. 1. 87 4 3. *.1.

8 5 9 8. *.2.18 9 7.. *.

1 e

e...

9 *

.9457 *

.8043

  • 1.0646 *

.9864

  • 1.1599
  • 1.0999
  • 1.1010 *

.6940 *

  • 2. 1490 *...... 2.e.5247
  • 1.9229
  • 2.0779.*. 1. 7526*.1. 8420..*.1. 8280.*eee.8653..*

2 e.

eeeeeeeeeeeeeeeeeee.

eee.

10 *

.9382

  • 1.0656 *

.9928

  • 1.1256
  • 1.0539
  • 1.0774
  • 1.0174 *

.7925 *

  • 2 2

e.. 1831.*.1. 9204.*. 2. 0675.*.1. 8120..*.1. 9397

  • 1.8792
  • 1 9905
  • 2.52 5
  • eeeeeeeeeeeee....eeeeeeeeeeeee.

11

  • 1.0817 *

.9907

  • 1.1310 *

.9302

  • 1.1545
  • 1.0346
  • 1.0303 *

.6400 *

  • 1.8792
  • 2.0690
  • 1.8063
  • 2.1749
  • 1.7665
  • 1.9742
  • 1.9635
  • 3.1090
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 1.1685
  • 1.0603
  • 1.1610
  • 1.0539
  • 1.0860 *

.9029

  • 12 *

.8996 *

. 2. 2442..*. 1. 7410.*. 1. 9281..*.1. 7579

  • 1.9450 *. 1. 8755
  • 2.2512
  • eeeeeeeeeeee eeeeeeeeeeee.

13

  • 1.0742
  • 1.1042
  • 1.0828
  • 1.0410
  • 1.0913'* 1.0185 *

.5580 *

  • 1 8743.*.1. 8350.*eee.8706.*.1 9621
  • 1.8646
  • 2.0016
  • 3.6468
  • 1 e..

... e e....eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.0817
  • 1.1031
  • 1.0217
  • 1.0367 *

.9093 *

.5741 *-

ee. 8598

  • 1. 8234
  • 1.9823
  • 1.9528
  • 2.2338
  • 3.5439
  • 1.eeeeee I

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15 *

.9082 *

.6940 *

.7958 *

.6512

-)

  • 2 1897.*. 2. 8682.*. 2. 5137..*. 3. 0924.*e M-8UB-Q e

ee....

)

i AT 75% POWER, 4 EFPD, THIS IS LEVEL 1 OF 18' (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) i

....H.....ee..Q.........F.........Ee e e e e n...D.........C......... B..... e... A. e e...

j 8 *

.3931 *

.3010 *

.5580 *

.3599 *

.5751 *

.7240 *

.5726 *

.5184

  • 1

. e. 0 0 57..*. 6. 53 4 5..*.3.

5 614..*. 5. 47 0 2..*. 3. 4 2 21

  • 2. 7 0 4 4
  • 2. 9 2 0 4 *e***eeeeeeee.3. 7461.*
  • 5 i

eeeee.

9*

.3010 *

.4959 *

.3491 *

.6019 *

.4091 *

.6715 *'.7015 *'.4327 *

  • e 5 3 4 5. *. 3. 9 8 9 3. *.5.

6 5 2 2. *.3.2 9 71..*. 4. 8.b. 5 8.

  • 2. 9 412..*. 2. 7 8 52..*. 4. 4 9 8 9.*.

6...

... ee..

10 *

.5580 *

.3502 *

.5837 *

.3759 *

.6340 *

.7111 *

.6201 *

.2485 *

  • 3 5614.*.5. 6411.*. 3. 4 0 2 0.*. 5. 2 514
  • 3.1191
  • 2.7 665.*e e e e.17 3 9
  • 7. 8 4 8 5.*.

3 e..

eeeeeeeeeeeeee***ee.

eeeeee.

11 *

.3599 *

.6051 *

.3781 *

.6008 *

.4081 *

.6330 *

.6158 *

.3941

  • eeee.eeeeeeeeeeeeees.e.eeeeeeeee 71
  • 4.8380
  • 3.1360
  • 3.1985'* 4.9884
  • i
  • 5.4702
  • 3.2784
  • 5.2324
  • 3.29 4

l

.eee.ee....eeeeeeeeeeeeeeeeeeeeeeeeeee 12 *

.5751 *

.4123 *

.6383 *

.4091 *

.6297 *

.65S7 *

.$323 *

  • 3. 4221
  • 4.7740
  • 3.0990
  • 4.8218..*.eee.1497
  • 3.0055
  • 3.7172
  • 3

...eeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeen i

13 *

.7240 *

.6737 *

.7144 *

.6362 *

.6619 *

.5933 *

.3438

  • 2 3.3429
  • 5.7765 *
  • 2.7044.*eee.9322
  • 2.7560
  • 3.e.1191
  • 2.9930
  • t eeeee..

eeeeeeeeeee,*eee eeeeeeeeeeee.eeeeeeeeeeeeeeeeeeee l

14 *

.6726 *

.7026 *

.6233 *

.6190 *

.5366 *

.3524 *

. 2. 9204......2. 7825.*.3. 1635.*. 3. 1809

  • 3.6887
  • 5.6301
  • eeeeeeeeeeeeeeeeeeeeeee 15 *

.5184 *

.4327 *

.2485 *

.3963

  • 4. 4 9 8 9. *.7.

8 273..*. 4 9. 6 2 7.. *e M-SUB-Q e

Catawba 2 Cycle 7 Core Operating Limits Report Page 37 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORRAL OPERATION AT 75% POWER, 150 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H F

E C

B A

eseeeeeeeee..G...eeeeeeeeeeeeeeeeeeeeee

  • Deeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.4188 *

.3748 *

.6555 *

.4562 *

.6565 *

.7754 *

.7229 *

.5687 *

  • 1.7920
  • 1.9178
  • 2.4126
  • e.2. 6975..*.3.5273.*.2. 1489.*. 3.0623
  • 2.1229

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9*

.3748 *

.5901 *

.4391 *

.6812 *

.4830 *

.7304 *'.7422 *

.4873

  • 813 0
  • 2.8163
  • e.3. 5273..*.2. 3.ee..*. 3. 1972..*. 2.e.0545
  • 2.8819
  • 1.9073
  • 1.870 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10 *

.6555 *

.4402 *

.6640 *

.4477 *

.6769 *-.7315 *

.6587 *

.2935 *

  • 2.1489..*. 3. 1972..*. 2. 1221.*.3. 1105
  • 2.0727
  • 1.9006
  • 2.1207
  • 4. 6647..*.

eeen.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11 *

.4562 8

.6854 *

.4487 *

.6148 *

.4145 *

.6105 *

.6019 *

.4204

  • e 3.0623..*.2. 0425.*.3. 1014.*.2. 1459..*. 2. 9856.*eee.0700
  • 2.1762
  • 3.1699
  • 2 ee

.ee.

eeeeeeeeeeeeeeeeeeeeeee.

12 *

.6565 *

.4862 *

.6790 *

.415K *

.5173'*

.5226 *

.4873 *

  • 2.0178
  • 2.0216
  • 2.4515
  • e.2. 12 2 9..*. 2. 8 6 2 3.. *.2.

0 6 4 5. *.2.

9 8 0 0 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13 *

.7754 *

.7315

  • 7336 *

.6126 *

.5248 *

.4380 *

.3138 *

  • 1.7920
  • 1.9039
  • 1.9034
  • 2.0652
  • 2.0178.*eee.3230
  • 3.4982
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeeeeeeeeeeee 14 *

.7229 *

.7422 *

.6597 *

.6030 *

.4894 *

.3192 *

. 1. 9178.*.1. 8700.*. 2. 1186..*. 2. 1710..*. 2. 4421.*.3. 4.448.*.

15 *

.5687 *

.4873 *

.2935

  • 1

.4295

  • 2 4126..*. 2. 9163..*.4. 6544.*. 3 1620'* M-SUB-Q n eeeee.

AT 75% POWER, 150 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 e BOTTOM)

H G

P E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen B*

.5687 *

.9810 *

    • M5
  • 1.1171 *

.9Lv6 + 1.0624

  • 1.0507 *..8857
  • f 1 5859
  • 1.8372
  • 1.6553
  • 1.6574
  • 1.9440
  • e.2. 3 7 81.. *.1.7 5 8 2..
  • e eess;

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9 *

.9810 *

.8675

  • 1 A.0153
  • 1.1331
  • 1.0656
  • 1.0560 *

.7004

  • eeeeeeeeeeeeeeeeeeeeeeee eeee. 7486.*. 1. 5524..*eee.6436
  • 1.6553
  • 2.4607 *
  • 1.7582
  • 2.0170
  • 1..

., a 1 1

eeeeeeeeeeeeeeeeeeeeeee.

10 *

.9885

  • 1.0839
  • 1.0174
  • 1.0892
  • 1.0142'* 1.0346 *

.9725 *

.7861 *

  • 1. 8050.*. 1. 6478..*. 1 7518.*.1. 6159..*.1. '7276..*. 1. 7114.*. 1 8063..*.2. 2037..*.

e.

11

  • 1.1171
  • 1.0196
  • 1.0935 *

.8868

  • 1.0196 *

.9082 *

.9082 *

.6308

  • e.1. 5.859
  • 1.7415
  • 1. 6136
  • 1.8930
  • 1 6136.e*eeee.7731
  • 1.8302
  • 2. 7206..*.

1 eeeeeeeeeee..

ee...eneeenesee eeeeeeeeeeeeeee.

12 *

.9596

  • 1.1406
  • 1.0195
  • 1.0217 *

.7015 *.7861 *.7336 *

  • 1. 8372..* 1. 542 2
  • 1.7 210
  • 1. 6112
  • 1.73 6 9
  • 1.e.7 3 8 8
  • 2.0 58 9 -
  • ee

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeeeeeeeeeene 13

  • 1.0624
  • 1.0667
  • 1.0389 *

.9114 *

.7893 *

.6597 *

.4573

  • e.. 6 5. 5 3..*. 1. 6 415..*. 1. 7 0 57..*. 1.7 6 91..*. 1. 7 3 4 2. *. 1. 8 5 9 8..*. 3. 0 418.*e
  • 1 ea 14
  • 1.0507
  • 1.0571 *

.9735 *.3104 *

.7368 *

.4659 *

. 1. 6574

  • 1.6542
  • 1.8037
  • 1.8259
  • 2.0518
  • 2.9877 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15 *

.8857 *

.7004 *

.7861 *

.6319

  • 1 9 440
  • 2. 4631
  • 2.2 018
  • 2. 7177..* M-BUB-Q

.....eeeeeeeeeeeeeeeeeeeee..

1 r

Catawba 2 Cycle 7 Core Operating Limits Report Page 33 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q CP MARGIN) - NORMAL OPERATION AT 75% POWER, 150 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1.=

BOTTOM)

.... H......... G......... F......... E......... D........ e *

  • e e e e e e e Be e e e e e... A..... e C

8 *

.6983

  • 1.2477
  • 1.2424
  • 1.3977
  • 1.1620
  • 1.2948
  • 1.2327
  • 1.0624
  • e.2. 1507
  • 1.5342
  • 1.5842
  • 1.3985
  • 1.6647
  • 1.4961
  • 1.5528
  • 1.7817
  • e***eeeeeeeeeeeeee+eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.-

9

  • 1.2477
  • 1.0753
  • 1.3730
  • 1.2691
  • 1.3891
  • 1.2702
  • 1.2649 *

.8075

  • e.1 53.42..*.1. 7980.*. 1. 4358 *.1. 5450..*.1.4064
  • 1.5295
  • 1.5210.* 2. 3369.*

eeeeeeeeeeeeeeeeeeee 10

  • 1.2424 *.1.3741
  • 1.2788
  • 1.3720
  • 1.2424
  • 1.2691
  • 1.1556 *

.9543 *

  • 1.5842
  • 1.4351
  • 1.5424
  • 1.4304
  • 1.5696
  • 1.5380
  • 1.6731
  • 1.9984
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee,eeeeeeeee 1.2723
  • 1.3730
  • 1.0903
  • 1.2756
  • 1.0956
  • 1.1021 *

.7561

  • 11
  • 1.3977 *
  • 1.3985
  • 1.7132
  • 1.4333
  • 1.6308
  • 1.f)L6 *'2.5150
  • eeeeeeeeee.1. 5406
  • 1.4306
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.1620
  • 1.3977
  • 1.2466
  • 1.2788 *

.8611 *

.9585 *

.8?50

  • 1.6647
  • 1.3985
  • 1.5640
  • 1.4309
  • 1.5850
  • 1.5866
  • 1.924C
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.2948
  • 1.2745
  • 1.2734
  • 1.0988 *

.9618 *

.7904 *

.5323

  • eeeeeeeeeeeeeeeeeeeeeeeeeee. 1. 6266
  • 1.5826
  • 1.7331
  • 2.9119 *
  • 1.4961
  • 1.5244
  • 1.5329 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2327
  • 1.2659
  • 1.1578
  • 1.1042 *

.8793 *

.5419 *

. 1 552*8

  • 1 5193.*.1. 6700.*.'1. 6712..*. 1 9174.*.2. 8602..*.

15

  • 1.0624 *

.8075 *

.9553 *

.7583

  • 1.7817
  • 2.3389
  • 1.9970
  • 2.5096
  • M-EUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen l

AT 75% POWER, 150 BFPD, THIS IS LEVEL 15 OF 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON) l l

H O

F E

D C

B A

l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

8*

.7936

  • 1.4287
  • 1.4094
  • 1.5797
  • 1.2927
  • 1.4459
  • 1.3516
  • 1.1652
  • l
  • 2

...eeeeeeeeeeeeeeeeeeeeeeeeeee.1. 7192.*e ee. 0340

  • 1.4280
  • 1.4819
  • 1.3119
  • 1.5766
  • 1.4188
  • 1.4990 *

..eeeeeeeeeeeeeeeeeeeeeee.

l' l

9

  • 1.4287
  • 1.2145
  • 1.5658
  • 1.4309
  • 1.5701
  • 1.4094
  • 1.4019 *

.8750 *

. 1. 4280..*.1. 6838.*. 1. 3349.*. 1. 4536

  • 1.3193
  • 1.4628
  • 1.4536
  • 2.2701
  • t

.eeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeee**ee 10

  • 1.4094
  • 1.5669
  • 1.4469
  • 1.5637
  • 1.3977
  • 1.4255
  • 1.2766
  • 1.0549 *
  • 1.4819
  • 1.3337
  • 1. 4437.e*eee.3356
  • 1.4846
  • 1.4533
  • 1.6099
  • 1 9181.*

1 e eeeeeeeeeeee**ee..

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen....

[

11

  • 1.5797
  • 1.4341
  • 1.5658
  • 1.2274
  • 1.4512
  • 1.2263
  • 1.2316 *

.8322 *

  • 1 e.. 3119.. *. 1. 4 4 9 8.. *. 1. 3 3 4 9.. *. 1. 6 27 7.. *. 1. 3 5 4 9. *. 1. 5 6 6 9. *. 1. 6116.. *. 2. 4 3 6 6.
  • i 12
  • 1.2927 e 1.5767
  • 1.4030
  • 1.4544 *

.9736

  • 1.0828 * :.9746
  • e ee.766..*.1. 3119..*. 1. 4793.*. 1. 3522
  • 1.5237
  • 1.5207
  • 1.8716 *
  • 1.5 eeeeeeeeeeeeeeeeeeeeeeeeeeeen.

1 13

  • 1.4459
  • 1.4137
  • 1.4309
  • 1.2295
  • 1.0860 *

.8911 *

.5890 *

  • 1. 4188......1. 4574.*.1. 4480.*. 1. 5625.*.1 5166
  • 1. 682.9.*. 2. 8543
  • 1 1

14

  • 1.3516
  • 1.4041
  • 1.2788
  • 1.2349 *

.9789 *

.6008 *

  • 1.4990
  • 1.4513
  • 1.6062
  • 1.6069..*. 1. 8637..*. 2. 8021..*

e eeeeeeeeeeeeeeeeee.**ee....eee.

i 15

  • 1.1652 *

.8750

  • 1.0560 *

.8343

  • ee 7192
  • 2.2701
  • 1.9155
  • 2 4324
  • M-SUB-Q
  • 1 e...eeeeeeeeeeeeeeeeeeeen.

eee i

l l

[

{

l 6

I

Catawha 2 Cycle 7 Core Operating Limits Report Page 39 of 144 i

Appendix A l

TABLE 1 (CONTINUED) i F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION 1

AT 75% POWER, 150 EFPD, THIS 18 LEVEL 14 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM) e...H.........G.......F.......... e e e e e... D......... C......... B. e e e e n e e e e e e.

]

B A

8*

.8643

  • 1.5230
  • A.4833
  • 1.6558 *'1.3420
  • 1.5058
  • 1.3902
  • 1.1931
  • 1 e.2. 0721.*.1. 4393.*eee.4971
  • 1.3353.*.1. 6173
  • 1.4593
  • 1.5615
  • 1. 7968..*.

1

... e eeeeeeeeee...

.eeeeeeeeeeeeeeeeeeee.

e 9

  • 1.5230
  • 1.2798
  • 1.6526
  • 1.4994
  • 1.6451
  • 1.4630
  • 1.4512 *

.8921 *

  • 1.4393
  • 1 6997
  • 1.3435.*.1.4784
  • 1.3441.* 1.5001
  • 1.5024
  • 2.3699
  • eeeeeeeeeeee

.eeeeeeeeee

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 10

  • 1.4833
  • 1.6536
  • 1.5107
  • 1.6504
  • 1.4651
  • 1.4930
  • 1.3205-* 1.0860
  • e.1 4971..*.1 3423.*. 1 4610..*. 1 3448.*. 1 507.4.*.1. 474.4.*.1. 6555..*.1. 9959..*.

11

  • 1.6558
  • 1.5015
  • 1.6526
  • 1.2927
  • 1.5455
  • 1.2959
  • 1.2916 *:.8579 *
  • 1.3353..*. 1. 4761
  • 1.3435
  • 1.6587..*. 1. 3858 *'1. 6220..*. 1. 6685.*. 2. 52.45.*

esee..

.eeeeeeeeeeeeeeeeee..

12

  • 1.3420
  • 1.6547 *.1.4716
  • 1.5497
  • 1.0656
  • 1.1695
  • 1.0324 *
  • 1.6173
  • 1.3359
  • 1.9589
  • eeeeeeeeeeeeeeeeeee 1. 5010
  • 1.3826
  • 1.5846
  • 1.5808
  • eeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.5058
  • 1.4683
  • 1.4983
  • 1.2991
  • 1.1738 *

.9821 *

.6287

  • e 1.4593.*.1. 4946.*. 1. 4684
  • 1.6167..*. 1. 5758..*.1 766.8.*.3. 0004.*.

ee....

...eeeeeee..

14

  • 1.3902
  • 1.4533
  • 1.3227
  • 1.2948
  • 1.0367 *

.6405 *

  • 1.5615
  • 1.5000
  • 1.6517
  • 1.6643
  • 1.9503
  • 2.9452 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1531 *

.8921

  • 1.0871 *-.8600
  • F-SUB-Q e 1. 7 9 6 8. *. 2. e. 3 7 2 0
  • 1.9932
  • 2.5200
  • M-sUB-Q eeeeee eeeeeeeeeeeeeeeeeeeeeee.

AT 75% POWER, 150 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C.

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8

  • 1.0249
  • 1.6579
  • 1.5904
  • 1.7671
  • 1.4234
  • 1.5979
  • 1.4641
  • 1.2531 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 6014
  • 1.8501 *
  • 2.0679
  • 1.4466
  • 1.5054
  • 1.3490
  • 1.6351
  • 1.4821
  • 1.eeeeeeeeeeeeee 9
  • 1.6579
  • 1.3805
  • 1.7736
  • 1.6033
  • 1.7543
  • 1.5551
  • 1.5380 *

.9350

  • e 1 4.466 *.... 1. 7003. *.1. 3484.*. 1 4907..*.1. 3578.*. 1. 5204.*. 1. 5267..*.,2.4362
  • ee.

eeeeeeeee 10

  • 1.5904
  • 1.7746
  • 1.6268
  • 1.7714
  • 1.5712
  • 1.5969
  • 1.3998
  • 1.1460'*

1.5149

  • 1.4836
  • 1.6787
  • 2.0311
  • e.1. 5054
  • 1. 3471..*.1 4702..*. 1. 3490
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7671
  • 1.6044
  • 1.7725
  • 1.3966
  • 1.6890 * '1.4126
  • 1.3891 *

.9082

  • 1....

1

... 3490..*eee.4891

  • 1.3484
  • 1.6642
  • 1. 3905..*.1 6403,* 1.6851.*.2.5691
  • eeeeeeeeeeeeeeeeeee......

.,e eeeeeee.. eeeeeene I

12

  • 1.4234
  • 1.7639
  • 1.5776
  • 1.6922
  • 1.2691
  • 1.3495
  • 1.1342 *

. 1 6351.*. 1. 3496..*.1 5085.*. 1. 3871..*. 1. 6148.*. 1. 6091..*. 1. 9979

  • 13
  • 1.5979
  • 1.5604
  • 1.6033
  • 1.4169
  • 1.3537
  • 1.1760 *

.7015

  • eeeeeeeeeeeeeeeeeeeeeeeeeeee.1. 6357
  • 1.6046
  • 1.8122
  • 3.0654 *
  • 1.4821
  • 1.5148
  • 1.4775 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.4641
  • 1.5401
  • 1.4030
  • 1.3934
  • 1.1385 *

.7154 *

  • 1.6014
  • 1.5251
  • 1.6758
  • 1.6808
  • 1.9891
  • 3.0003 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 15
  • 1.2531 *-.9339
  • 1.1481 *. 910 4
  • 2.0282
  • 2.5645
  • M-SUB-Q e...

.eeeeeeeeeeeeeeeeeeeeeee i

I

1 Catawba 2 Cycle 7 Core Operating Limits Report Page 40 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 75% POWER, 150 NFPD,.

THIS IS LEVEL 12 OF 18 ILEVEL 18 m TOP OF CORE, LEVEL 1. BOTTOW)

B A

e...H.........G......... F........E......... D.........C. e e e e e e e e e e e e e e e e e e e e e e e 8* 1.1610

  • 1.7243
  • 1.6333
  • 1.8175
  • 1.4469
  • 1.6290
  • 1.4823
  • 1.2659 *

. 2. 1936..*.1 5093..*. 1. 5897..*. 1. 4263.*.1. 7439... 1. 57 4 0. *. 1. 710. 4. *.1.

9 7 2 9..

  • 9* 1.7243
  • 1.4223
  • 1.8250
  • 1.6418
  • 1.8025
  • 1.5862
  • 1.5647 *

.9425 *

. 1. 5093..*.1 7912..*. 1. 4200..*. 1. 5776.*.1. 4312..*.1. 613.4.*. 1. 6232.*.2. 6089.*

10

  • 1.6333
  • 1.8271
  • 1.6666
  • 1.8239
  • 1.6151 *'1.6397
  • 1.4266'*.1.1642 *
  • 1.5897
  • 1. 4186.*.1.e.5540
  • 1.4207
  • 1.5967.e*eee.5647
  • 1.7807
  • 2.1565
  • 1 eeeeeeeeee.

eeeee **eneeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeee

  • 1.4705
  • 1.4330 *

.9243

  • 11
  • 1.8175
  • 1.6440
  • 1.8250
  • 1.4437
  • 1.7639
  • 1. 4263..*.1. 5759.*.1. 4193.*.1 7536.*.1.4614.*.1 7378.*.1 77.52.*. 2. 7213..*

e..

e**ee.

12

  • 1.4469
  • 1.8089
  • 1.6204
  • 1.7682
  • 1.4758
  • 1.4758
  • 1.1988
  • l
  • 1.743 1

- 1 eeeeee.9.*. 1. 4262. *eee.5906

  • 1.4577
  • 1.7023
  • 1.6907
  • 2.1141 *

... e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.6290
  • 1.5926
  • 1.6461
  • 1.4748
  • 1.4791
  • 1.2970 *

.7454 *

  • 1. 57 40
  • 1. 6 07 2
  • 1. 5 5 80
  • 1.73 2 6
  • 1. 6 8 57..
  • e ee. 9 04 5
  • 3. 2 371 * '

1 e.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e

eeeeeeeeeeeeee.

1 14

  • 1.4823
  • 1.5669
  • 1.4298
  • 1.4362
  • 1.1942 *

.7593 *

  • e e e e e e e e e e e e e e e e e e e e e e e e e.. 1.7 6 9 8
  • 2.10 43
  • 3.177 7 *
  • 1.7104 8'1.6206
  • 1.7764
  • eeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.2659 *

.9414

  • 1.1663 *

.9264

. 1.9729

  • 2 6089.*.2. 1533
  • 2.71.62e* M-SUB-Q I

eeeeeeee.e.....

eeeeeeeee e

AT 75% POWER, 150 EFPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

H" Q

F E

D C'

B

'A e+eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1835
  • 1.7447
  • 1.6397
  • 1.8303
  • 1.4448
  • 1.6311
  • 1.4758
  • 1.2606 *

)

. 2. 3708 *... 1 6 2. 51. *.1.7 2 4 9.. *. 1. 5 4 3 0. *. 1. 919 3.. *.1.

710 5. *. 1. 8 5 9 8.. *.2. e.13 6 3

  • eeeeee 9
  • 1.7447
  • 1.4298
  • 1.8389
  • 1.6472
  • 1.8153
  • 1.5872
  • 1.5647 *

.9350 *

- )

. 1. 6251..*.1. 9573..*. 1. 5348.*. 1. 7137..*. 1. 5.470..*.1. 7.529.*. 1 7624

  • 2.8579

. eeeeeeeeeeeeee.

10

  • 1.6397
  • 1.8410
  • 1.6750
  • 1.8378'* 1.6226
  • 1.6483
  • 1.4255
  • 1.1620 *

. 1.e.7249

  • 1.5332
  • 1 6858..*. 1. 5356.*. 1. 7290..*.1. 6915..*.1 9317.*. 2.e.3384
  • eeeeeee**eee.....

eeeee.

11

  • 1.8303
  • 1.6483
  • 1.0389
  • l'4555
  • 1,7896
  • 1.4908
  • 1.4448 *

.9243

  • l eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 9074 *1..ee..
2. 9478
  • 1.5430
  • 1.7117
  • 1.5340
  • 1.9091
  • 1.5654
  • 1.8633
  • 12
  • 1.4448
  • 1.8228
  • 1.6290
  • 1.7950
  • 1.5176
  • 1.5187
  • 1.2001
  • 1
  • 1.8188
  • 2.2743 *

. 1. 919 3. *. 1. 5 413.. *.1.7 218..*. 1. 5 62 0.*e e e e. 8 3 4 9 eeeeeeeeeeeeeeeeeeeeeese-13

  • 1.6311
  • 1.5926 *'1.6558
  • 1.4962
  • 1.5230
  • 1.3398 *

.7615 *

  • 1. 7105..*. 1. 7466.*. 1. 6847..*.1. 8574.*. 1. 8130..*. 2. 0577..*. 3. 5376..*

14

  • 1.4758
  • 1.5669
  • 1.4287
  • 1.4491
  • 1.2134 *

.7754 *

  • 1.8598
  • 1.7603
  • 1.9278.*. 1.e.9024
  • 2.2654
  • 3.4730
  • i eeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeee 15

  • 1.2606 *

.9350

  • 1.1642 *

.9253

. 2. 1363 *.2. 8607..*. 2. 3365..*. 2. 9.418..* M-SUB-Q

)

. e 1

i l

Catawba 2 Cycle 7 Core Operating Limits Report Page 41 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 75% POWER, 150 EFPD, THIS IS LEVEL 10 OF 18

.(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) e eeeeee.................eeeeeeeeeeeeeeeeeeeee..C..eeeeeeeeeeeeeeeeee**ee H

Q F

E D

B A

8* 1.2081

  • 1.7832
  • 1.6708
  • 1.8689
  • 1.4683
  • 1.6611
  • 1.4994
  • 1.2809
  • e.2. 5230.*.1. 7213..*.1. 8385
  • 1.6448
  • 2.0812
  • 1.8420
  • 1.9864
  • 2.2760 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 9

  • 1.7832
  • 1.4566
  • 1.8785
  • 1.6772
  • 1.8550
  • 1.6151
  • 1.5936 *

.9478 *

  • 1.7213
  • 2.0964
  • 1.6364
  • 1.8327
  • 1.6500
  • 1.0902
  • 1.8939
  • 3.0795
  • seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10
  • 1.6708
  • 1.8807
  • 1.7061
  • 1.8775
  • 1.6536
  • 1.6836
  • 1.4512
  • 1.1835
  • e.1. 8385.*. 1. 6355.*.1. 8018.*.1 6373..*. 1. 8586.*. 1 8185.*. 2. 0794.*.2. 5072..*e

.e*

e..

11

  • 1.8689
  • 1.6793
  • 1.8785
  • 1.4855
  • 1.8336
  • 1.5251
  • 1.4780 *

.9393

  • e.1. 6.448.*e 8303.*. 1 6364
  • 2 0574.*. 1. 6763..*.1. 9967..*.2 0417..*.3. 1658..*.

1...

1

.. eeeeee...

.. e 12

  • 1.4603
  • 1.8614
  • 1.6611
  • 1.8389
  • 1.5583
  • 1.5658
  • 1.2391
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.1 9312
  • 2.4231 *'
  • 2.0812
  • 1.6523
  • 1.8515
  • 1.6714
  • 1.9588
  • eeeeeeeeeeeeen-13
  • 1.6611
  • 1.6215
  • 1.6900
  • 1.5305
  • 1.5701
  • 1.3816 *

.7529

  • 1.8841
  • 1.8116
  • 1.9912
  • 1.9248
  • 2.1817
  • 3.7823 *

. 1. 8420 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***

14

  • 1.4994
  • 1.5958
  • 1.4544
  • 1.4823
  • 1.2445 *

.7979

  • e.1. 9864.*.1. 8915.*. 2. 0764
  • 2.0373
  • 2.4130
  • 3.7139
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.2809 *

.9478

  • 1.1856 *

.9414

  • 2.2760
  • 3.0795
  • 2.5050
  • 3.1591
  • M-SUB-Q.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

AT 75% POWER, 150 IFPD, THIS IS LEVEL ' 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

H G

F E

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..D.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8* 1.1781

  • 1.7500
  • 1.6333
  • 1.8336
  • 1.4319
  • 1.6268
  • 1.4662
  • 1.2520
  • 2.5742
  • 1.7378
  • 1.8634
  • 1.6609
  • 2.1190
  • 1.8670
  • 2.0572
  • 2.3890
  • eeenaeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9
  • 1.7300
  • 1.4223
  • 1.8443
  • 1.6386
  • 1.8207
  • 1.5787
  • 1.5615 *

.9243

  • e***eeeeeeeeeeeeeeeeeeeee.74..*.1. 6744.*.ee 9281...*.1. 9476
  • 3.2416
  • 2.1363
  • 1.6523
  • 1.85 1

e.1. 7378

  • eeeeeeeeeeeeee.

10

  • 1.6333
  • 1.8453
  • 1.6665
  • 1.8421
  • 1.6183 + 1.6515
  • 1.4191
  • 1.1567
  • e.1 8 6 3 4.. *. 1. 6 514.. *. 1. 8 2 8 0.. *. 1. 6 5 4 2.. *. 1. 8 2 41. *. 1. 8 4 4 4. *. 2. 14 5 8. *. 2. e. 6 2 81
  • eeeee.

11

  • 1.8336
  • 1.6408
  • 1.8443
  • 1.4533
  • 1.8025
  • 1.4951
  • 1.4501 *

.9168

  • i
  • 1.6609
  • 1.8562
  • 1.6523
  • 2.0960
  • 1,6930
  • 2.0441
  • 2.1036
  • 3.3237 *
      • eeeeeeeeee.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

12

  • 1.4319
  • 1.8271
  • 1.6247
  • 1.8068
  • 1.5272
  • 1.5401
  • 1.2156 *

. 2. 119 0. *.1. 6 67 6. *e e e e. 87 67

  • 1. 6 8. 81. *. 2. 0 016.. *.1.

9 87 8..*. 2. 5.15 9

  • 1 1

eeeeeeeeee 1

13

  • 1.6268
  • 1.5851
  • 1.6590
  • 1.4994
  • 1.5455
  • 1.3500 *

.7668 *

  • 1. 8 6 7 0.. *.1 9 2 0 4.. *. 1 8 3 7 3..
  • 2. 0 3 6 9.. *. 1. 9 810.. *.2.

2 5 47.. *. 3 9 9 4 8.. *e i

j

[

14

  • 1.4662
  • 1.5626
  • 1.4223
  • 1.4544'* 1.2209 *

.7808

  • 2.0 2

i e e. e. 5 7 2.. *. 1. 9 4 5 0. *e e. 1410.. *. 2. 0 9 7 5. *. 2. 5 0 5 0.. *e

3. 918 9
  • l

.eee 15

  • 1.2520 *

.9232

  • 1.1588 *

.9189

  • 2.6257
  • 3.3160
  • M-SUB-Q
  • 2.3890
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

1 l

l l

i t.

Catawba 2 Cycle 7 Core Operating Limits Report Page 42 of 144 -

Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-sUB-Q VALUES (F-803-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER, 150 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

F E

D C

B A

e...H.........G........... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

1.1888

  • 1.7725
  • 1.6536
  • 1.8603
  • 1.4480
  • 1.6493
  • 1.4865
  • 1.2713
  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.4 0
  • 2. 00 0 5
  • 1.7 5 9 0
  • 1. 9 2 5 5
  • 2. 21 2.4985
  • 1.6734
  • 1.7917
  • 1.59..eeeeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeee 9

  • 1.7725
  • 1.4373
  • 1.8710
  • 1.6590
  • 1.8475
  • 1.6001
  • 1.5862 *

.9361 *'

  • 1. 6734..*. 2. 0572
  • 1.5896..*.1. 7862..*. 1. 6064.*. 1. 8385 *.... 1 8246.*. 3. 0117..*.

e.

eeeeee*ee..

10

  • 1.6536
  • 1.8721
  • 1.6868
  • 1.8689
  • 1.6386
  • 1.6772
  • 1.4394
  • 1.1749 *
  • .2.4415 *
  • e e e e e e e e. 1. e. 5 8 8 7...*.1.7 6 3 3 *eeeeeeeeeee.913
  • 1.8142.*.1. 7644
  • 2.0369 1.5
  • 1.7917
  • e..

eeeeeeeeee..

eeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.8603
  • 1.6611
  • 1.8700
  • 1.4716
  • 1.8303
  • 1.5165
  • 1.4748 *

.9286 *

  • 1.5940
  • 1.7851
  • 1.5905
  • 2.0269
  • 1.6364
  • 1.9796
  • 2.0113
  • 3.1326
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.4480
  • 1.8550
  • 1.6461
  • 1.8346
  • 1.5487
  • 1.5679
  • 1.2349 *
  • 2.0085
  • 1.5966
  • 1.8074
  • 1.6318
  • 1.9450
  • 1.9255
  • 2.4312 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.-

13

  • 1.6493
  • 1.6065
  • 1.6847
  • 1.5208
  • 1.5733
  • 1.3816 *

.7775

  • e.1. 7 5 9 0. *.1.8 315.. *. 1. 7 5 6 9. *.1.

9 7 2. 9. *. 1. 9 2 0 4. *.2.

18 81. *. 3. 8 613..

  • 14
  • 1.4865
  • 1.5872
  • 1.4426
  • 1.4791
  • 1.2402 *

.7925 *

  • 1. 9 2 5 5.*. 1. e. 8 2 3 4
  • 2. 0 3 4 0
  • 2. 0 071.*. 2. 4 210..*. 3. 7 9 5 4.*.

eeeeee..

eeeeeeeeeeeeeeeeeee..

15

  • 1.2713 *

.9361

  • 1.1760 *

.9307

eeeeeeeeeeeeeeeeeeeeeeeeeeeee. 1292

  • M-SUB-Q 2.2149
  • 3.0117
  • 2.4394
  • 3.eeee.

AT 75% POWER, 150 EFPD, THIS 18 LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeee.....E.eeeeeeeeeeeeeeeeeeeeeeeeeeee*****eeeeeeee 1.7500

  • 1.6301
  • 1.8389
  • 1.4255
  • 1.6311
  • 1.4705
  • 1.2595
  • 8* 1.1663
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeee. 4699
  • 1.8622
  • 1.6263
  • 1.7829
  • 2.0513 *
  • 2.3655
  • 1.5570
  • 1.6500
  • 1..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.7500
  • 1.4137
  • 1.8496
  • 1.6365
  • 1.8282
  • 1.5819
  • 1.5712 *

.9232 *

  • 1. 5570..*. 1. 9140..*. 1. 4676.*. 1. 6504
  • 1. 4827..*.1 6930..*. 1. 6822.*. 2. 7960.*

10

  • 1.6301
  • 1.8518
  • 1.6622
  • 1.8485
  • 1.6103
  • 1.6611
  • 1.4234
  • 1.1620
  • eeeeeeeeee**,.. 1.6812
  • 1.6254
  • 1.8755
  • 2.2512
  • i 1

1.4699 *

  • 1.6500.*. 1. 4669.*eeee.6336
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee+

i eee**ee.

11

  • 1.8389
  • 1.6376
  • 1.8496
  • 1.4512
  • 1.8111
  • 1.4983
  • 1.4608 *

.9168 *

  • 1.4699
  • 1.6486
  • 1.4684
  • 1.8890
  • 1.5274
  • 1.8491
  • 1.8646
  • 2.8941

I eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 12 + 1. 42 5 5

  • 1. 8 3 57
  • 1. 62 47
  • 1. 8164
  • 1. 53 0 5
  • 1. 55 40
  • 1. 2 2 2 0 *

. 1. 8622..*.1.4744.*. 1. 6744.*. 1 5233..*. 1. 8503..*. 1. 8108.*. 2. 2618..*

e**e..

13

  • 1.6311
  • 1.5872
  • 1.6686
  • 1.5037
  • 1.5594
  • 1.3687 *

.7679

  • i
3..*. 1. 6 871...* e e e. 6181
  • 1. 8 4 4 4. *. 1. 8 0 5 2.. *.2.

0 5 57.. *. 3. 6 013.. *.

  • 1.626 1

eeeeeeeeee...

eeeeee.

14

  • 1.4705
  • 1.5722
  • 1.4266
  • 1.4651
  • 1.2274 *

.7829 *

  • 1. 7829..*. 1. 6802..*. 1. 8718..*.1. 8598..*.2.2529.*. 3. 5309..*

i 1

15

  • 1.2595 *

.9243

  • 1.1642 *

.9189

  • 2. 0513..*. 2. 7960.*. 2. 2494..*.2. 8883.*. M-SUB-Q w

b Catawha 2 Cycle 7 Core Operating Limits Report Page 43 of 144 1

Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & H-SUB-Q VALUES (F-SUB-Q OP HARGIN)

NORMAL OPERATION AT 75% POWER, 150 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 m TOP OF CORE,. LEVEL 1 = BOTTOM)

H G

F E

D B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..C.eeeeeeeeeeeeeeeeeeeeee.

8* 1.1160

  • 1.6868
  • 1.5690
  • 1.7757
  • 1.3720
  • 1.5765
  • 1.4212 *.1.2199 *
  • 1.7774
  • 1.5462
  • 1.6970
  • 1.9515.*

l

1. 5757..*.1. 3939
  • 2.2166
  • 1.4676 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

    • eeeeeeeeeeeeee....

9

  • 1.6868
  • 1.3570
  • 1.7864
  • 1.5754
  • 1.7682
  • 1.5272
  • 1.5208 *

.8921

  • 1.5948
  • 2.6694 *
  • 1 4676.*.1.8154
  • 1.3893
  • 1.5706
  • 1.4014
  • 1.6046
  • eee

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen.

10

  • 1.5690
  • 1.7886
  • 1.6001
  • 1.7864
  • 1.5604
  • 1.6076
  • 1.3752
  • 1.1245
  • e 1. 57 57.. *.1.3 8 8 6.. *.1. 5 5 0 3. *.1.

3 9 0 6. *.1 5 8 87.. *. 1. 53 3 9.. *. 1. 7 7 3 0. *.2.

13 47. *.

ee ee....

e 11

  • 1.7757
  • 1.5765 *-1.7864
  • 1.3966
  • 1.7522
  • 1.4469
  • 1.4148 *

.8846 *

-* 1.3939

  • 1.5689
  • 1.3899
  • 1.7774
  • 1.4263
  • 1.7285
  • 1.7441
  • 2.7351
  • eeee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.3720
  • 1.7746
  • 1.5669
  • 1.7575
  • 1.4769
  • 1.5048
  • 1.1813
  • 12
  • e.1. 7774.*.1. 3960.*.1.5826
  • 1.4228
  • 1 2223
  • 1.6881
  • 2.1113 *

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen.

13

  • 1.5765
  • 1.5326
  • 1.6140
  • 1.4523
  • 1.5101
  • 1.3259 *

.7390

  • l
  • 1. 5462..*.1. 5993.*. 1. 5274..*.1. 7233..*. 1. 6822.*. 1. 9191..*. 3. 3820.*. -

14

  • 1.4212
  • 1.5230
  • 1.3784
  • 1.4191
  • 1.1877 *

.7540 *

  • 1. 6970.e*.1. 5931..*. 1. 7698.*.1e.7389
  • 2.1021
  • 3.3160
  • e eeeeeeeeeeeeeeeeeeeeeeen 15
  • 1.2199 *

.8921

  • 1.1256 *

.8868

. 1. 9 515.. *. 2. 6 6 9 4. *.2.1316. *. 2. 7 2 7 3.. *e N-SUB-Q l

j

..e i

AT 75% POWER, 150 BFPD,.THIS IS LEVEL 5 OF 18

)

(LEVEL 18 = TOP OF. CORE, LEVEL 1 e BOTTON) 1

....H.........G.........F.........E.........D..e.....C.........B.........A......

f 8

  • 1.0956
  • 1.6633
  • 1.5476
  • 1.7554
  • 1.3559
  • 1.5626
  • 1.4148
  • 1.2167
  • I
  • 2. 0690..*. 1 3747..*. 1. 4781.*. 1. 3069.*e. 6695.*. 1. 4478..*. 1. 5843
  • 1.8200
  • 1 e.

. e eeeeeeeeeeeeeee 9

  • 1.6633
  • 1.3366
  • 1.7661
  • 1.5562
  • 1.7511
  • 1.5144
  • 1.5144
  • 8879
  • eeeeeeeeeeeeeeeeeeeeeee.04.*. 1. 4721
  • 1.3093
  • 1.4973
  • 1.4865
  • 2.4942 *
  • 1.3747
  • 1.7030
  • 1.30..

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.5476
  • 1.1682
  • 1.5797
  • 1.7671
  • 1.5444
  • 1.5947
  • 1.3677
  • 1.1192 *
  • 1.4781
  • 1.2993
  • 1.4521
  • 1.2993
  • 1.4819
  • 1.4291
  • 1.6495
  • 1.9851
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 11
  • 1.7554
  • 1.5572
  • 1.7671
  • 1.3816
  • 1.7372 8.1.4362
  • 1.4084 *

.8782

  • eseeeeeeeeeeeeeeeeeeeeeeeeeeeeee.52..*.1.3225..*.1 5948
  • 1.6118
  • 2.5402 *
  • 1.3069
  • 1.4706
  • 1.2998
  • 1.65

. eeeeee

..eeeeeeeeeeeeeeeeeeeeee.

12

  • 1.3559
  • 1.7575 a 1.$50s
  • 1.7414 a 1.4651
  • 1.4983
  • 1.1760 *
  • 1. 6695.*.1. 3040.*.1. 4759..*. 1. 3188..*. 1. 5740..*. 1. 5371.*. 1. 9358
  • e.

13

  • 1.5626
  • 1.5208
  • 1.6022
  • 1.4416
  • 1.5037
  • 1.3205 *

.7336

  • e.1 4 47 8..
  • e e 4 919.. *.1.

4 2 2 8.*.1. 5 8 9 6.*.1. 5 3 2 2.. *. 1. 7 410.*. 3. 0 8 91..

  • 1 14
  • 1.4148
  • 1.5165
  • 1.3698
  • 1.4126
  • 1.1824 *

.7486

  • 1.6457
  • 1.6073
  • 1.9268
  • 3.0307 *
  • 1. 5843..*. 1 4850
  • e**e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15
  • 1.2167 *

.8879

  • 1.1213 *

.8804

  • 2.4920
  • 1. 9837
  • 2.5358.* M-SUB-Q eeeeeeeeeeee..

.eeeeeeee...

l i

I Cctawba 2 Cycle 7 Core Operating Limits Report Page 44 of 144 i

Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION I

AT 75% POWER, 150 EFPD, THIS IS LEVEL 4 OF 18 I

(LEVEL 18 = TOP OF CORE, LEVEL 1 s BOTTON)

I I

H G

F B

D.

C B

A

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

1.0121

  • 1.5476
  • 1.4405
  • 1.6386
  • 1.2659
  • 1.4673
  • 1.3355
  • 1.1513 *

.j 8

  • e e e. 9 6 0.*. e e e. 3 8 5 9
  • 1. 4919
  • 1. 3140
  • 1. 67 82
  • 1. 4 4 8 5
  • 1. 577 4
  • 1. 8 0 97 *
  • 2.0 1

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee I

9

  • 1.5476
  • 1.2424
  • 1.6504
  • 1.4501-* 1.6397
  • 1.4234
  • 1.4287 *

.8365 *

  • 1. 3859.*. 1. 7202..*.1. 3057..* 1. 4819..*e 1.3105
  • 1.4950.*.1.e.4796
  • 2.4877
  • e,*eeeeeeeee.ee..

eeeeeeeeeeeeeee 10

  • 1.4405
  • 1.6515
  • 1.4716
  • 1.6536
  • 1.4437
  • 1.4983
  • 1.2873
  • 1.0549 *
  • 1 4919.*. 1. 3.045.*.1. 4617..*. 1. 3004.*.1. 4857..*.1. 4256..*.1 6420.* 1. 9783.*

j e..

ee.

e...

11

  • 1.6386
  • 1.4523
  • 1.6536
  • 1.2906
  • 1.6290
  • 1.3484 + 1.3270 *

'.8257

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 3176
  • 1.5852
  • 1.5993
  • 2.5336.*.
  • 1.3140
  • 1.4804
  • 1.3004
  • 1.6571
  • 1 eeeeeeeeeeeeeeeeeeeeeeee...

12

  • 1.2659
  • 1.6472
  • 1.4501
  • 1.6343 *-1.3752
  • 1.4116
  • 1.1096 *
  • 1. 6782
  • 1.3051
  • 1.4789
  • 1.3140
  • 1.5595
  • 1.5161
  • 1.9128.*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4673
  • 1.4287
  • 1.5058
  • 1.3527
  • 1.4169
  • 1.2477 *

.6897

  • 1
  • 1.4485
  • 1.4896
  • 1.4193 *'1.5800
  • 1.5106
  • 1.7111
  • 3.0564 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeese 14
  • 1.3355
  • 1.4309
  • 1.2906
  • 1.3313
  • 1.1149 *

.7036

  • e.1. 5774.*.1. 4774
  • 1. 6383
  • 1.5948
  • 1.9027
  • 2.9961
  • ee..

..eeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1513 *

.8375

  • 1.0571 *

.8279

. e e e e e e e e e e e e e e e e e e e e e *

  • e 52 91
  • M-SUB-Q
  • 2.4877
  • 1.9756
  • 2
  • 1. 8097 eeeee.

AT 75% POWER, 150 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)'

eeeeeeeeeeeeeeeeeeeeee

.......E.eeeeeeeeeeeee....C'

~ B A

H G

F D

eeeeeeeeeeeeeeeeeeeeeee.

B*

.9307

  • 1.4201
  • 1.3259
  • 1.5080
  • 1.1813
  • 1.3709
  • 1.2649'* 1.0881'*

+

I

  • 2.16 8 4.*e e e e. 43 55
  • 1. 5412
  • 1. 3 516
  • 1 7121. *.1.47 44
  • 1. 5 852
  • 1. 82 4 6
  • 1 eeeeee..

eeeeeeeeeeeeeeeeeee.........

..eeeeeeeeeeeeeeeeeeee 9

  • 1.4201
  • 1.1470
  • 1.5208
  • 1.3398
  • 1.5187
  • 1.3355
  • 1.3452 *

.7947 *

      • e.355.*. 1. 7719..*.1. 3471..*.1. 5250
  • 1.3440
  • 1.5138 *'1.4942
  • 2.4963 *-
  • 1.4..

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee t

10

  • 1.3259.* 1.5219
  • 1.3591
  • 1.5283
  • 1.3409
  • 1.3987
  • 1.2124 *

.9896 *.

. 1 5412..*.1. 3459.*. 1 5043..*. 1. 33.65.*.1 5185..*. 1. 4507..*. 1. 6571

  • 2.0071
  • eeeeeeeeeeeeee.

11

  • 1.5080
  • 1.3409
  • 1.5283
  • 1.2017
  • 1.5123
  • 1.2616
  • 1.2456 *

.7743 *

  • 1.3516
  • 1.5233
  • 1.3372
  • 1.6890
  • 1.3471
  • 1.6055
  • 1 6172..*. 2. 5696.*

ee***e ee

  • e.ee*

eeeeeeeeeeeeeee........................

12

  • 1.1813
  • 1.5251
  • 1.3473
  • 1.5165 e 1.2863
  • 1.3227
  • 1.0464 *
  • 1.7121
  • 1.3390
  • 1.5122
  • 1.3434
  • 1.5791
  • 1.5314
  • 1.9229
  • seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3709
  • 1.3409
  • 1.4062
  • 1.2670
  • 1.3270
  • 1.1770 *

.6522

  • e.1. 47 4 4
  • 1 5 0 8 2
  • 1. e. 4 4 4 9. *. 1.e. 6 0 01. *. 1. 52 5 8
  • 1. ?161
  • 3. 0 62 8
  • I

..ee.ee.

ee.ee..

e..

e.

.eeeeee**eeeeeeeeee eee i

14

  • 1.2649
  • 1.3473
  • 1.2156
  • 1.2488
  • 1.0517 *

.6662 *

  • 1.5852
  • 1.4919***eee.6533
  • 1.6127..*.1. 9128..*. 3 0024.*.

1 j

eeeeeeeeeeeeee..

ee***eeeee.

i t

I 15

  • 1.0881 *

.7947 *

.9917 *

.7765

4985.*. 2. 0043.*.2.5651

  • M-SUB-Q
  • 1.8246
  • 2

..... eeeee.e.

eeeee.ee.ee.

l i

i i

i I

i Catawba 2 Cycle 7 Core Operating Limits Report Page 45 of 144 l

Appendis A l

TABLE 1 (CONTINUED) l F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER, 150 BFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H 0

F E

D C

B A

    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7711

  • 1.1406
  • 1.0785
  • 1.2284 *

.9939

  • 1.1492
  • 1.1010 *

.9211

  • 1.8246
  • 1.59..48.*. 1. 9608.*. 1. 6920.*. 1. 7.569.*.2. 0809.*
  • 2.5247
  • 1.7202
  • j e eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

I 9

  • 1.1406 *

.9457

  • 1.2252
  • 1.0924
  • 1.2563
  • 1.1395
  • 1.1503 *

.6983

  • l eeeeee.2..*eee.0704
  • 1.6091
  • 1.7984
  • 1.5562
  • 1.7090
  • 1.6841
  • 2.7401 *
  • 1.720 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10
  • 1.0785
  • 1.2263
  • 1.1063
  • 1.2381
  • 1.1181
  • 1.1695
  • 1.0410 *

.8215 *

. 1. 8 2 4 6.. *..1.6 07 3. *.1 7 7 7 4. *. 1. 5 8 2 6. *. 1. 7 4 8 3...*.1.

6 6 8 6. *.1 8 610..' *. 2. e. 3 3 4 9

  • eeeee*

11

  • 1.2284
  • 1.0956
  • 1.2424
  • 1.0057
  • 1.2370
  • 1.0678
  • 1.0496 *

.6533 *

  • 1 5948..*.1. 7940 *...... 1. 5783.*. 1. 9410.*.1 5843..*.1.e.8257
  • 1.8467
  • 2.9442
  • e..

eeeeeeeeeeeeeeeeeeeeeee.

12 *

.9939

  • 1.2616
  • 1.1235
  • 1.2402
  • 1.0731
  • 1.1160 *

.8932

  • 1..5487..*.1 7399.*. 1. 5800
  • 1. 8200
  • 1.7452
  • 2.1684.*
  • 1.9608
  • eeeeeeeeeeeeeeeeee....

eeeeeeeeeeee 13

  • 1.1492
  • 1.1438
  • 1.1738
  • 1.0710
  • 1.1203
  • 1.0014 *

.5676 *

  • 1.7389
  • 1.9397
  • 3.3940 *
1. 7030.*. 1. 6628.*.1.8200
  • 1.6920 *

..... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeee...

14

  • 1.1010
  • 1.1513
  • 1.0432
  • 1.0539 *

.8986 *

.5794

  • e.1. 7 5 6 9
  • 1. 6 8 2 2
  • 1. 8 57 4.+.1. 8 4 0 8
  • 2.157 0
  • 3. 3 2 3 7 *

..e....

..eeeeeeeeeeeeeeeeeeeee.

15 *

.9211 *

.6972 *

.8225 *

.6544

  • 2. 0809. e*****e.. 7...*.2. 3330
  • 2. 9382..* M-SUB-Q
  • 2.750 l

AT 75% POWER, 150 EFPD, THIS IS LEVEL 1 OF 18 l

(LEVEL 18 s TOP OF CORE, LEVEL 1 a BOTTOM) s e e.......... O...... e e. F......... E.........D....... e e a e e..... B. e *

  • e e e e e s e e e e.

H 9

A 8 *

.4927 *

.4102 *

.6490 *

.4605 *

.6297 *

.7840 *

.7133 *

.5548

  • e.3. 8306... 4. 6065.*.2. 9293.*.4 102.6.*.2. 9961
  • 2.4069
  • 2.6425
  • 3.3781 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 9*

.4102 *

.5880 *

.4562 *

.6683 *

.4969 *

.7219 *

.7508 *

.4562 *

  • 4.6065 *
  • eeeeee... 3. 2271..*. 4. 1618
  • 2. 8400
  • 3.7954
  • 2.6209
  • 2.5094
  • 4.0968
  • ee..

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

10 *

.6490 *

.4562 *

.6565 *

.4712 *

.6801 *

.7743 *

.6608 *

.2870 *

. 2. 9293..*.4.1558..*.2. 8.883..*.4.0115..*. 2. 7906.*. 2. 4477..*. 2. 8568... 6 4759..*.

11 *

.4605 *

.6704 *

.4734 *

.6405 *

.4830 *

.6662 *

.6544 *

.4155

  • l
  • 4.1026
  • 2.8316
  • 4.0004
  • 2.9532
  • 3.9031
  • 2.8373
  • 2.8825
  • 4.5059
  • i eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*e eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12 a

.6297 *

.4991 *

.6633 *

.4852 *

.6640 *

.6983 *

.5569 *

  • 2.9961
  • 3.7755
  • eeeeeeeeeeeeeeeeee 2.7772
  • 3.8925
  • 2.8484
  • 2.7094
  • 3 3900..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

i 13 *

.7840 *

.7229 *

.7765 *

.6683 *

.7004 *

.6180 *

.3652 *

. 2 4069... 2. 613 8. *. 2. 4 3 9 4. *. 2. 8 2 8 9.. *. 3. 6 9 9 3. *. 3. 0 5 9 6. *. e e 14 8 4.. *.

5 l

eeeee.

14 *

.7133 *

.7518 *

.6619 *

.6565 *

.5591 *

.3727 *

  • 2.6425
  • 2.5072
  • eeeeeeeeeeeeeeee... 2. 8512... 2. 8710 *... 3. 3741. *.5 0406 15 *

.5548 *

.4562 *

.2881 *. 415 5

. 3. 3 7 81

  • 4. 0 9 6 8
  • 6. 4 614
  • 4. 4 9 8 9
  • M-SUB-Q

.......eeeeeeeeeeeeeeeeeeeeeeeee I

m 1

Catawba 2 Cycle 7 Core Operating Limits Report' L Page 46 of 144 l

Appendix A t

TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER,- 415 EPPD,.THIS IS LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H

'O F'

E D

C' B'

A neeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen. neeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.6319 *

.6340 *

,9478 *

.7358 *

.9457

  • 1.0785
  • 1.0078 *

.8193 *

  • 1.9478
  • 2.3787
  • 1.6006
  • 2.0568
  • 1.6035
  • 1.4090
  • 1.5048
  • 1.8353
  • eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.-

l l

9 *

.6340 *

.8675 *

.7165 *

.9714 *

.7508

  • 1.0217
  • 1.0314 *

.6919

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.29..*

2.3787

  • 1.7439
  • 2.1134
  • 1.5621
  • 2.0184
  • 1.4888
  • 1.4702
  • 2.17 l

10 *

.9478 *

.7165 *

.9596 *

.7154 *

.9607

  • 1.0292 *

.9232 *

.4745 *

  • 1. 6006.*.2. 1113.*.1. 5821.*.2. 1155..*. 1.5826
  • 1.4775
  • 1.6441
  • 3. 1510..*.

i

.eeeeeeeeeeeeee*eeeeeeeeee.

11 *

.7358 *

.9735 *

.7165 *

.8761 *

.6373 *

.8611 *

.8514 *

.6158 *

  • 2.0568
  • 1.5569
  • 2.1134
  • 1.7297
  • 2.2890
  • 1.7424
  • 1.7771
  • 2.4389
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 9457 *

.7540 *

.9618 *

.6383 *

.7133 *

.7390 *

.5887 *

  • 2.0556
  • J035
  • 2.0088
  • 1.5796
  • 2.2877
  • 1.6616
  • 1.6749 e.et eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 13 *

.0785

  • 1.0239
  • 1.0303 *

.8611 *

.7401 *

.6223 *

.4670 *

  • 1.4090
  • 1.4852
  • 1.4754
  • 1.7410
  • 1.6729
  • 1.8474 8 2.7911
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen i

14

  • 1.0078
  • 1.0314 *

.9232 *

.8525.*

.6897 *

.4712 *

.)

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 0516..*.2.e.7618 *

  • 1.5048
  • 1.4702
  • 1.6434
  • 1.7756
  • 2...

j eeee.

l 15 *

.8193 *

.6919 *

.4745'*

.6158

  • 1.8353
  • 2.1729
  • 3.1488
  • 2.438 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeense.9.* M-sUB-Q I

l l

AT 75% POWER.

415 EFPD,' THIS IS LEVEL 17 OF 18 i

(LIVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON)

H G

F E

D C

B A

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7786

  • 1.3462
  • 1.3184
  • 1.4748
  • 1.2584
  • 1.3934
  • 1.3088 8'1.1224 *

. 1. 8502..*. 1. 4108..*. 1. 4414.*. 1. 2887..*.1. 5051

  • 1.3623
  • 1.4445
  • 1.6708
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

i I

9

  • 1.3462
  • 1.1792 *-1.4405
  • 1.3345
  • 1.4694
  • 1.3430
  • 1.3323 *

.8868

  • l e 1.4108
  • 1.6072
  • 1.3207
  • 1.4235.*.1. 2922.*. 1. 4129.*eeee.4219
  • 2. 1157..*.

1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeee.

~

j-10

  • 1.3184
  • 1.4416
  • 1.3377
  • 1.4351
  • 1.2970
  • 1.3291
  • 1.2145
  • 1.0389
  • 1 1.5561
  • 1.8062
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 4655.*.eee.4298 *
  • 1.4414
  • 1.3200
  • 1.4216
  • 1.3258
  • 1....

e+eeeeeeeeeeeeeeeeeeeeen 11

  • 1.4748
  • 1.3377
  • 1.4351
  • 1.1620
  • 1.3259
  • 1.1385 e 1.1535.*

.8086 *-

1.2887

  • 1.4208
  • 1.3258
  • 1.6331
  • 1.4250
  • 1.6299
  • 1.6410
  • 2.3208
  • eseesseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenaaeasesasetaaeaeeenasseeeeeeeeen 12
  • 1.2584
  • 1.4748
  • 1.3002
  • 1.3280 *

.8750 *

.9810 *

.9114 *

  • 1.5051 + 1.2874
  • 1.4626
  • 1.4243
  • 1 1

l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 5725.*.see.5686

  • 1.9207
  • eeeeeeeeeeeeeee l

I 13

  • 1.3934
  • 1.3452
  • 1.3323
  • 1.1395 *

.9821 *

.8204 *

.6040 *

  • 1. 3 6 2 3. *.1e. 4 0 9 5
  • 1. 4 2 7 4. +. 1. 6 27 9..
  • 1. 5 6 67.. *.1.

7 3 21 *.2. 67 3 7.. *.

l-eeeeee.

ee.ee.eeeee.

eee l

14

  • 1.3088
  • 1.3323
  • 1.2156
  • 1.1545 *

.9136 *

.6094 *

  • 1.4445
  • 1.4219
  • 1.5572
  • 1.6394
  • 1.9164
  • 2.6475
  • I l

i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1224 *

.8868

  • 1.0389 *

.8086

  • 1.8062
  • 2.3208
  • M-sUB-Q e**e. 081.67..*eee.1166 eeeeeeeeeeeeeeeeeeeeeeee n

c.+

m p

i r

I i

Catawba 2 Cycle 7 Core Operating Limits Report Page 47 of 144 Appendix A -

TABLE 1 (CONTINUED) i l

(

F-SUB-Q E M-SUB-Q VALUES (F-8US-Q OF MARGIN) - NORMAL OPERATION AT 75% POWER, 415 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18's TOP OF CORE, LEVEL 1 m BOTTOM)

H Q

F E

D C

B A

e ee.....eeeeeeeeeeeeeeeeeeeeeeeeeeeee.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

~

I 8 *

.8846

  • 1.5272
  • 1.4865
  • 1.6590
  • 1.3816
  • 1.5476
  • 1.4062
  • 1.2252 *

. 1. 8 0 5 3. *.1 3 5 2 0. *. 1. 3 8 5 6..*.1 2 3 8 9

  • 1. 4 7 7 7.. *. 1 3 27 8. *.1. e. 4 5 6 3
  • 1. 6 5 9 7.. *e e**ee.

eeeeee.

9

  • 1.5272
  • 1.3141 + 1.6354
  • 1.5005
  • 1.6515
  • 1.4651
  • 1.4576 *

.9403

  • y

. 1. 3520..*.1 5612..*.1. 2610..*. 1.3724 8. 1. 2455.a. 1. 4023..*. 1. 4080.*e. 1553.*.

j 2

.e

    • e

.. e 10

  • 1.4865
  • 1.6365
  • 1.5058
  • 1.6279
  • 1.4448
  • 1.4791
  • 1.3130
  • 1.1428
  • 1.5589
  • 1.7818
  • e.1. 3856.*. 1. 2608.*.1. 3710.*.1. 2699
  • 1.4253
  • 1.3907 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

(

11

  • 1.6590
  • 1.5015
  • 1.6279
  • 1.2852
  • 1.4865
  • 1.2413
  • 1.2670 *

.8793

  • 1
  • 1. 2389ee.1 3717..*.1. 2696 *... 1. 5964..a. 1. 3747.eee'1.6072
  • 1.6169
  • 2.3094
  • a e.

eeeeeeeeeeeeeeeeeeeeeeeeee i

12

  • 1.3816
  • 1.6568
  • 1.4469
  • 1.4876 *'.9821
  • 1.0764 *

.9832

  • eeeee**ee. 1. 2418.e*eee.4224
  • 1.3737
  • 1.5560
  • 1.5524
  • 1.9281 *
  • 1.4777 *-

1 e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.5476
  • 1.4683
  • 1.4812
  • 1.2424
  • 1.0774 *

.8846 *

.6372 *

  • 1.3278
  • 1.3987
  • 1.3882
  • 1.6057
  • 1.5502
  • 1.7432
  • 2.7370
  • eeeeeeeeeeeeeeeeeeeeeeeeeee**eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.4062
  • 1.4576
  • 1.3141
  • 1.2670 *

.9842 *

.6437 *

  • 1.4563
  • 1.4080
  • 1.5580
  • 1.6159
  • 1.9246
  • 2.7111
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15
  • 1.2252 *

.9393

  • 1.1428 *

.8793

  • 1.659 e e e e e e.7.. *.2.

15 61. *. 1. 7 818. *.2.3 0 9 4.

  • M-SUB-Q I

AT 75% POWER, 415 BFPD, THIS IS LEVEL 15 OF 18' (LEVEL 18 = TOP OF CORE, LEVEL 1.= BOTTOM).

l H

G F

B D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.7157

  • 1.3977
  • 1.5765 *.1.4137
  • 1.2370
  • 8*

.9200

  • 1.5733
  • 1.5219
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 1 3466
  • 1.4952
  • 1.6997 *
  • 1.8186
  • 1.3619
  • 1.4011
  • 1.2d28
  • 1.5032 *. eeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5733
  • 1.3388
  • 1.6847
  • 1.5347
  • 1.6900
  • 1.4812
  • 1.4758 *

.9403 *

(

. 1. 3619..*. 1 5787..*.1. 2683..*.1. 3884

  • 1 259.6.*.1. 4329.*. 1 4357..* 2. 2120
  • t

.e***

ee

..e I

10

  • 1.5219
  • 1.6847
  • 1.5369
  • 1.6729
  • 1.4694
  • 1.5080
  • 1.3216
  • 1.1556 *
  • 1.4011
  • 1.2677
  • 1.3887
  • 1.27 1.4116
  • 1.6041
  • 1.8197
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.70..*.1. 4510
  • e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.7157
  • 1.5347
  • 1.6729
  • 1.3045
  • 1.5187
  • 1.2552
  • 1.2841 *

.8857 *

  • 1.s5a4
  • 2.3a11 *

)

  • 1.2428
  • 1.3861
  • 1.2770
  • 1.6219
  • 1.3925 *-1.6457 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee==

l 12

  • 1.3977
  • 1.G954
  • 1.4716
  • 1.5208
  • 1.0078
  • 1.0924 *.

.9896~*

1

. 1. 5032..*eeee.2559

  • 1.4483
  • 1.3911.*.1. 5965.*. 1. 5919.*. 1. 9911.*.

i eeeeeeeeeeeeeeeeee.....

l 13

  • 1.5765
  • 1.4844
  • 1.5112
  • 1.2563
  • 1.0946 *

.8932 *

.6372

  • j
  • 1. 3466..*. 1. 4300..*. 1. 4095..*.1. 6442..*.1. 5896.*.1. 8019. *.2. 8386.*

l 14

  • 1.4137
  • 1.4758
  • 1.3216
  • 1.2841 *

.9917 *

.6426 *

  • 1. 4 9 5 2. *. 1. 4 3 57..*. 1 6 0 3 5. *. 1. 6 5 8 0.
  • e e e. 9 8 8 2
  • 2. 8110
  • 1 l

eeeeeeeeeeeeee.

15

  • 1.2370 *

.9403

  • 1.1555 *

.8846

. 1. 6997..* 2. 2138.*. 1. 8197..*. 2. 3820..*e M-SUB-Q I

l-t l

l l

I l

.~

i t.

l-Catawba 2 Cycle 7 Core Operating Limits Report Page 48 of 144 Appendix A l

TABLE 1 (CONTINUED).

I F SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER, 415 EFPD,- THIS IS LEVEL 14 CF 18 (LEVEL'18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G.........F....eeeeee........D.........C..'.......B.........A......

E h'

8*

.8900

  • 1.5197
  • 1.4651
  • 1.6579
  • 1.3377
  • 1.5133
  • 1.3516
  • 1.1813
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeee**eeeeeee. 1 8589 *
  • 1.9404
  • 1.4643
  • 1.5303
  • 1.3481
  • 1.6403
  • 1.4701
  • 1.6385 *

...eeen 9

  • 1.5197
  • 1.2863
  • 1.6311
  • 1.4748.*'1.6268
  • 1.4169
  • 1.4148~*

.9954 *

-* 1.4643

  • 1.7197 *-1.3759
  • 1.5179
  • 1.3737
  • 1.5713
  • 1.5678.* 2.4166
  • emeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eseeeeeeene 10
  • 1.4651
  • 1.6311
  • 1.4758
  • 1.6161
  • 1.4105
  • 1.4501
  • 1.2616
  • l'.1063.*
  • 1. 5303.*.1. 3757..*.1. 5203.*.1. 3890.*.1. 5895.*.1 5431.*. 1. 7639..*. 1. 9939.*.

e.

11

  • 1.6579
  • 1.4758 *~1.6172
  • 1.2499
  • 1.4630
  • 1.2027
  • 1.2316 *

.8461

  • e e
  • s e.4 81.*.

1 5171.*.1 3 87 9..*. 1 7715

  • 1. 49 67
  • 1.7 82 4
  • 1. 82 00
  • 2. 6201
  • 1.3.. -

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.3377
  • 1.6322
  • 1.4126
  • 1.4641 *

.9714

  • 1.0507 *

.9489 *

  • 1.6403
  • 1.3694'*.* 5872
  • 1.4951
  • 1.7398
  • 1.7315.*.2. 1662
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

..eee 13

  • 1.5133
  • 1.4201
  • 1.4523
  • 1.2030
  • 1.0528 *.55s9 *

.6094 *

  • 1.4701
  • 1.5682
  • 1. 5409
  • 1.7813
  • 1.7304
  • 1.9707
  • 3.0970
  • eeeeeeeeeeeeeeeeee..

eeeeeeeeeeeeeeeeeeeeeeeeeee**** eeeeeeeen i

14

  • 1.3516
  • 1.4148
  • 1.2616
  • 1.2316 *-.9500 *-.6148 *
  • 1.6385
  • 1.5678 *-1.7639
  • 1.8200
  • 2.1629
  • 3.0664
  • eeeeee* eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeee 15
  • 1.1813 *

.8943

  • 1.1053 *

.3450

  • F-SUS-Q e.1. 8589......2. 417B *...... 1 9939
  • 2.6226~* M-SUB-Q

. eeeeeeeeeeeeee.

AT 75% POWER, 415 EFPD,- THIS IS LEVEL 13 OF 18

(

(LEVIL 18 m TOP OF. CORE, LEVEL 1 - = Boff 0N) eeeeeeee.....G........F....e.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.A H

E D

C B

eeeeene 8*

.8879

  • 1.5144
  • 1.4555
  • 1.6536
  • 1.3238
  • 1.5037
  • 1.3355
  • 1.1717 *
  • 2. 0176..*. 1. 5252..*. 1. 6.498.*. 1. 4443.*. 1. 7602..*.1. 5775..*. 1. 7628..*.1. 9904.*.

e.

9

  • 1.5144
  • 1.2777
  • 1;6301
  • 1.4641
  • 1.6161
  • 1.4019
  • 1.4030 *

.8868

  • e 1.5252
  • 1 8041..*.1. 472.4
  • 1.6365.*.,1.e.4770
  • 1.6955
  • 1.6835
  • 2.5780
  • eeeeeeeeee eeeeee..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.4555
  • 1.6301
  • 1.4651
  • 1.6161
  • 1.4009
  • 1.4416 *.1.2499 *'1i0988 *
  • 1.6498
  • 1 4720
  • 1.6407
  • 1.4566
  • 1 7130
  • 1.6594
  • 1.8993
  • 2.1361
  • eeeeeeeee*e eeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.6536
  • 1.4641
  • 1.6161
  • 1.2413
  • 1.4576
  • 1.1963
  • 1.2284 *. 8418
  • e.1. 4443..*. 1. 6365.*. 1. 4859.*. 1. 8412.e*eeee.5626
  • 1.8662
  • 1.8996
  • 2.8121
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.6226
  • 1.4030
  • 1.4587 *

.9682'* 1.0539 *

.9500

  • 12
  • 1.3238 *
  • 1.7602
  • 1.4713
  • 1.7109
  • 1.5615
  • 1.8355
  • 1.5215
  • 2.2649
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

l 13

  • 1.5037
  • 1.4041
  • 1.4437
  • 1.1974
  • 1.0560 *

.5654 *

.6137 *

. 1. 57 7 5.. *. 1. 6 915. *. 1. 6 57 0.. *.1.

8 6 5 0

  • 1. 819 2 e *e e e e. 07 4 3
  • 3. 2 3 2 5
  • 2 eeeeeeeee**e eeeeeeeeeeeeeee 14
  • 1.3355
  • 1.4030
  • 1.2499
  • 1.2284 *'.9510 *

.6201 *

  • 1 7628..*. 1. 6845..*. 1. 8999.*. 1. 0992
  • 2.2626
  • 3.2005
  • e..

eeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1717 *

.8857

  • 1.0978 *

.8407

. 1. 9 9 0 4.* e e 57 9 0.*.2.1377

  • 2. 814 9
  • M.SEB-Q '

2

. eeeeeeeeeee.

l i

t i

i '

h

.,,,. ~,

Catawha 2 Cycle 7 Core Operating Limits Report Page 49 0f 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER, 415 BFPD, THIS IS LEVEL 12 OF 18 (LEVEL'18 = TOP OF CORE, LEVEL 1 = BOTTOM)

D C

-B A

e...H.........G.........F.........E. e e e e e e e e e e e e.... e e e e e e e e e e e e e e e e e e e e e e e e.

  • 1.1395
  • 8*

.8857

  • 1.4930
  • 1.4212
  • 1.6172
  • 1.2841
  • 1.4641
  • 1.2959

. 2 1775.*.1. 6441.*. 1. 7895.*.1. 5876..*.1. 9574.*.1. 7.417..*.1. 9472..*.2. 1892..*.

9

  • 1.4930
  • 1.2509
  • 1.5001
  • 1.4266
  • 1.5797
  • 1.3612
  • 1.3645 *

.8600 *

  • 1. 6 4 41. *.1 9 5 6 0. *.1 5 914. *.1.7 9. 4 0. *.1.6 27 6.. *.1 87 8 0. *.1.
8. 5 5 9. *.2. e. 8 4 7 8
  • e.

.ee.

eeeee.

10

  • 1.4212
  • 1.6001
  • 1.4298
  • 1.5851
  • 1.3687
  • 1.4094
  • 1.218a
  • 1.0710 *
  • 1.7895
  • 1.5914
  • 1.7805
  • 1.6038
  • 1.8485
  • 1.7912
  • 2.0769
  • 2.3498
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.6172
  • 1.4266
  • 1.5862
  • 1.2167
  • 1.4394
  • 1.1813
  • 1.2092 *

.8236 *

  • 1.5876
  • 1.7 1.6029
  • 1.9918
  • 1.6792
  • 2.0030
  • 2.0374
  • 3.0288 *
  • eeeeeeeeeeee.9.40 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 12

  • 1.2841
  • 1.5862
  • 1.3698
  • 1.4405 *

.9714

  • 1.0614 *

.9478 *

. 1 95?.4..*. 1 6219.*. 1 8.462...*.1. 67.02

  • 1 9400.*ee 9354
  • 2.4160
  • 1 eeeeeeeeeee 13
  • 1.4641
  • 1.3634
  • 1.4105
  • 1.1813
  • 1.0624 *

.8825 *

.6190 *

  • 1. 7 417.. *.1 87 4 3. +.1 7 9 0.1. *. 2. 0 017.. *. 1. 9 3 2 8.. *.2.

2 0 0 5. *. 3. 4 3 9 5..*

  • eeeeee 14
  • 1.2959
  • 1.3645
  • 1.2188
  • 1.2092 *

.9489 *

.6244 *

  • 2.0384
  • 2.4133
  • 3.4036 *
  • 1.9472..*.1 8571..*.2. 0769 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeee.

15

  • 1.1395 *

.8600

  • 1.0710 *

.8236

  • F-SUB-Q e.2. 18 9 2.. *.2.8 4 9 4. *.2.3 5 07.. *. 3. 03 2 0..*e M-8UB-Q AT 75% POWER, 415 EFPD, THIS IS LEVIL 11 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOH)

F E

B A

....H......... Q.. e e e e e e e e e e e e e e e e e........D.........C... e e e e e e e e e e e e e e e e e e e e e 8*

.9639

  • 1.4887
  • 1.3923
  • 1.5819
  • 1.2488
  • 1.4255
  • 1.2584
  • 1.1085 *
      • e 994.a. 1. 7849.*. 1. 9522..*. 1. 7292..*.2. 1717..*. 1.e.9249
  • 2.1594
  • 2.4198 *
  • 2.3 ee.

eeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.4887
  • 1.2338
  • 1.5712
  • 1.3923
  • 1.5444
  • 1.3238
  • 1.3291 *

.8354 *

  • 1.7849
  • 2.1493
  • 1.7294
  • 1.95 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.99..*. 1 7695..*.2. 0518

...... 2.0494.*eee.1823

  • 3 eeeee.

10

  • 1.3923
  • 1.5712
  • 1.3987
  • 1.5583
  • 1.3420
  • 1.3859
  • 1.1931
  • 1.0474
  • e.1. 9522..*. 1. 7295..*.1. 9.417..*.1. 7400
  • 2 0090.*.1 9391.*. 2. 2541.*. 2. 5729.*

11

  • 1.5819
  • 1.3923
  • 1.5583
  • 1.2027
  • 1.4394
  • 1.1824
  • 1.1995 *

.8097 *

  • 1.7292
  • 1.9599
  • 1.7398
  • 2. 1853..*.1. 8204..*.2. 1746... 2. 1939.*. 3. 2696..*.

eeeeeeeeeeeeeeeeeee.........

12

  • 1.2488
  • 1.5497
  • 1.3430
  • 1.4405
  • 1.0571
  • 1.1192 *

.9628 *

  • e1717
  • 1.7653 82.eeeeeeeeeeeeeeeee.0064
  • 1.8192
  • 2.1281
  • 2.0901
  • 2.6122
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4255
  • 1.3259
  • 1.3869
  • 1.1835
  • 1.1203 *

.9564 *

.6394

  • e.1. 9 2 4 9. *. 2. 0 5 0 4. *.1.

9 3 7 8.. *. 2. 17 3 0

  • 2. 0 8 81
  • 2. 3 7 4 2
  • 3. 7 4 6 2 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.2584
  • 1.3180
  • 1.1931
  • 1.1995 *

.9639 *

.6458 *

  • 2.1594
  • 2.0494
  • 2.2544
  • e eeeeeeeeeeeeeeeeeeeeeeeee. 2. 1939.*.2. 6094.*. 2. 7073.*

15

  • 1.1085 *

.8343

  • 1.0464 *

.8097

  • 2.4198
  • 3.1823
  • 2.5752
  • 3.2733
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen

=

=

1 i

I Catawba 2 Cycle 7 Core Operating Limits Report

' Page 50 of 144 Appendix A i

TABLE l' (CONTINUED)

F-SUB-Q te M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 75% POWER,- 415 EFPD, THIS IS LEVEL 10 OF 18

)

(LEVEL 18 = TOP OF CORR, LEVEL 1 = BOTTOM)

......................F.........B.......ee.........C.. eeeeeen.e.....A H

G D

P eeeeee 8* 1.0924

  • 1.5272
  • 1.4041
  • 1.5947
  • 1.2499
  • 1.4298
  • 1.2584 1.1128
  • 1
  • 2.5912
  • 1.9102
  • 2.1036
  • 1.8562
  • 2.3634
  • 2.0672
  • 2.!!10
  • 2.6044
  • eneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5272
  • 1.2541
  • 1.5915
  • 1.3998
  • 1.5551
  • 1.3302
  • 1.3334 *

.8375

  • seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.8
  • 1.8964
  • 2.2076
  • 2.1963
  • 3. 4570.*e
  • 1.9102
  • 2.3327
  • 1.8550
  • 2.112

...eeeeeeeeeeeeeeeeeeeeeeeeeee.

i 1.4052

  • 1.2038
  • 1.0549
  • 10
  • 1.4041
  • 1.5915
  • 1.4084
  • 1.5776
  • 1.3559
  • 2

-me. 1036..*. 1. 8550..*. 2. 0929..*. 1. 0646

  • 2.1603
  • 2.0739
  • 2.4109
  • 2.7445
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

.I 11

  • 1.5947
  • 1.3998
  • 1.5707
  • 1.2252
  • 1.4823
  • 1.2252
  • 1.2284 *

.8725 *

)

i

. 1. 8562..*.2. 1128.*.1. 8646.*. 2. 3653

  • 1.9421
  • 2.3171
  • 2.3308
  • 3.4785
  • ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

j 3

12

  • 1.2499
  • 1.5604
  • 1.3570
  • 1.4833
  • 1.2113
  • 1.2349
  • 1.0110
  • l
  • 2.3634
  • 1.0927
  • 2.1570
  • 1.9408
  • 2.2701
  • 2.2150
  • 2.7587 8.

eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.4298
  • 1.3313
  • 1.4052
  • 1.2263
  • 1.2370
  • 1.0764 *

.6822

  • ee. 0672..*. 2. 2059..*.2 0727..*.2. 3153.*.2. 2133.*e. 5134.*.3. 9838.*

2....

  • 2 ee..

.... e 14

  • 1.2584
  • 1.3334
  • 1.2038
  • 1.2284
  • 1.0121 *

.6887 *

  • 2.3310
  • 2.1964
  • 2.4130
  • 2.3312
  • 2.7556
  • 3.9455
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1128 *

.8365

  • 1.0549 *

.8215

  • 2. 6044.*.3. 4570.*.2. 7464.*eee.4827..* M-SUB-Q 3

e.

e..

AT 75% POWER, 415 EPPD,- THIS IS LEVEL 9 OF 18 I

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) l eeeeeeeeeeeeeeeeen....F.....eee E*

  • e e. e...D..........Ce e e... e e e e e e e e e.

.A...... -

H Q

B 8

  • 1.1063
  • 1.5176
  • 1.3762
  • 1.5626
  • 1.2177
  • 1.3966
  • 1.2284
  • 1.0860
  • 2149.*.1. 9542.*. 2.5115..*.2. 1947
  • 2'.4899
  • 2.7798 *
  • 2.7196
  • 1.9988
  • 2
  • emeeeeeeeeeeeeeeeeee ee..

eeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5176
  • 1.2349
  • 1.5637
  • 1.3687
  • 1.5240-* 1.3013
  • 1.3055 *

.8150

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.86.*.2.e.0057
  • 2.3501
  • 2.3463
  • 3.7124
  • 1.9988
  • 2.4602
  • 1.9515
  • 2.22...

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3762
  • 1.5637
  • 1.3794
  • 1.5508
  • 1.3313
  • 1.3837
  • 1.1813
  • 1.0346 *
  • 2.2149
  • 1.9515
  • 2.2098
  • 1.9675.*.2. 2886.*. 2. 2065..*. 2. F857..? 2. 9.472. *.
    • eeeeeee.eeeeeeeeeeeeeeeeeeeee.. e 11
  • 1.5626
  • 1.3687
  • 1.5508
  • 1.2092
  • 1.4758
  • 1.2242
  • 1.2188 *

.8097

  • i
  • 3.7 I

. 1.e.9542..*e 2303.*.1. 9661

  • 2.5094.*. 2. 0542..*. 2. 4728 *... 2. 4963......... 559 2

e.

e

..eeeeee..

)

12

  • 1.2177
  • 1.5272
  • 1.3323
  • 1.4769
  • 1.2413
  • 1.2670
  • 1.0174
  • l
  • e e.115. *. 2. 0016.*. 2. 2 8 6 8. *. 2. 0 5 4 2.. *.2.

417 0.. *.2.3. 5 7 4. *.2.9 6 8 4.. *.

2.5...

13

  • 1.3966
  • 1.3023
  • 1.3837
  • 1.2252
  • 1.2651
  • 1.1106 *

.6919

  • e. 2. 19 47.. *. 2. 3 4 8 2. *.2.

2 0 4 8. *. 2. 47 07.. *. 2. 3 6 5 5.. *. 2. 6 918.. *. 4. 3 3 67.. *.

14

  • 1.2284
  • 1.3055
  • 1.1813
  • 1.2188
  • 1.0185 *

.6994 *

  • 2.4899
  • 2. 3463
  • 2.5880
  • 2.4985
  • 2.9654
  • 4.2916 *

....................eeeeeeeeeeeeeeeeeeeee.

15

  • 1.0860 *

.8150

  • 1.0335 *

.8086

  • 2. 7798.*.3. 712.4
  • 2. 9472..*. 3. 7608
  • M-sUB-Q e.

eeeee 1

.~.

Catawba 2 Cycle 7 Core Operating Limits Report Page 51 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION j

l AT 75% POWER, 415 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8

  • 1.1363
  • 1.5572
  • 1.3987
  • 1.5936
  • 1.2338
  • 1.4201
  • 1.2456
  • 1.1053
  • i i

. 2. 6474.e*e.1. 9217

  • 2 1222.*. 1. 8.658.*. 2 3713.*.2. 0516..*.2. 3000.*. 2. 5476..*-

1

.e*ee...

ee..

9

  • 1.5572
  • 1.2574
  • 1.5959
  • 1.3902
  • 1.5551
  • 1.3216
  • 1.3280 *..8290 *
  • 3.3944
  • e e e e.217..*e e e e. 3 5 5 8 *eeeeeeeeeeeeeeeeeee 31..*.1. 9039.*e2.2149
  • 2.1746 1.8670
  • 2.13
  • 1.9 2

.... eeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.3987
  • 1.5958
  • 1.4019
  • 1.5840
  • 1.3548
  • 1.4125
  • 1.2038
  • 1.0549 *
  • 2.1222
  • 1.8670
  • 2.1190
  • 1.8804
  • 2.1815
  • 2.0839
  • 2.4109 *'2.6914
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5936
  • 1.3902
  • 1.584C
  • 1.2338
  • 1.5144
  • 1.2563
  • 1.2499 *

.8279 *

  • 1.8658
  • 2.1331 *
  • 2.3349
  • 3.4507
  • eeeeeeeeeeeeeeee... 1. 8004
  • 2. 3989
  • 1.9661.* 2.3539

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2338
  • 1.5583
  • 1.3559
  • 1.5155
  • 1.2820
  • 1.3130
  • 1.0507
  • s e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.61..*.2.

3 4 63.*.2. 2 671..*.2. 7 8 52..*.

  • 2.3713
  • 1.8989
  • 2.1798
  • 1.96 l

I 1.4126

  • 1.2574
  • 1.3152
  • 1.1556 *

.7186

  • I 13
  • 1.4201
  • 1.3216
  • 2.5673
  • 4.0339 *
  • 2. 0516.*.2. 2132..*.2. 0824.*.2. 3520.*. 2. 2635 *#

I e.

e eeeeeeeeeeeeeen.

14

  • 1.2456 + 1.3200
  • 1.2027
  • 1.2499
  • 1.0517 *

.7261

  • e 2 3008
  • 2.1763
  • 2.4109
  • 2.3349
  • 2.7825
  • 3.9948 *-

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15

  • 1.1053 *

.8279

  • 1.0539 *

.82 68

  • 2. 5 47 6. *. 3. 3. 9 51.. *. 2. 6 9 3 9..*. 3 4 5 4 9.*.

M-SUB-Q e.

AT 75% POWER, 415 EFPD, THIS IS LEVEL 7 OF 18 l

{ LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM) e...H........G........F.........E.........D.........C.........B........A......

j i

8

  • 1.1406
  • 1.5669
  • 1.4009 *'1.6011
  • 1.2327
  • 1.4223
  • 1.2456
  • 1.1074 *

. 2. 3616.*.1. 7100.*. 1. 8900.'*. 1. 6542

  • 2.1008
  • 1.8155
  • 2.0432
  • 2 2638.*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

i 9

  • 1.5669
  • 1.2595
  • 1.6044
  • 1.3912
  • 1.5615
  • 1.3216
  • 1.3313 *

.8290

  • e.1. 7100.*. 2. 1021.*.1 6591.*. 1. 8972..*.1. 6855 *...... 1. 9642..*.1. 9255.* 3. 0195.*

10

  • 1.4009
  • 1.6033
  • 1.4030
  • 1.5904
  • 1.3570
  • 1.4191
  • 1.2059
  • 1.0581
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee****ee... 2. 1385
  • 2.3798 *
  • 1.8900
  • 1.6593
  • 1.8888
  • 1.6724
  • 1.9464
  • 1.8530
  • j

...eeeeeeeeeee i

11

  • 1.6011
  • 1.3912
  • 1.5915
  • 1.2359
  • 1.5262
  • 1.2627
  • 1.2574 *

.8311 *

  • 1. 6542
  • 1.8983........................ 2. 1426 *......... 547
  • 2.1051
  • 2. 0809..*. 3.0656.*
  • 1.6724
  • 1.7

]

e.

.ee...

e 12 a 1.2327

  • 1.5637
  • 1.3560
  • 1.5262
  • 1.2906 e 1.3260
  • 1.0603
  • l

. 2. 1000.*. 1. 6.806.*. 1 9451.*. 1. 7537

  • 2.0975
  • 2.0212
  • 2.4877
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4223
  • 1.3227
  • 1.4191
  • 1.2638
  • 1.3291
  • 1.1695 *

.7251

  • 1.8530
  • 2.1051
  • 2 0198
  • 2.2886
  • 3.6103 *
  • 1.8155..*. 1 9642
  • eeeeee.

.....eeeeeeeeeeeeeeeeeee....eeeeeeeeeeeeeeeeeee.

14

  • 1.2456
  • 1.3313
  • 1.2049
  • 1.2574
  • 1.0614 *

.7336 *

  • e n e 4 3 2.*.1. 9 2 6 8
  • 2. 14 01..*.~.2.

0 8 2 4.*.2. 4 8 5 6

  • 3. 57 4 6..
  • 2.0..

15

  • 1.1074 *

.8279

  • 1.0571 *

.8300

  • F-SUB-Q e.. 2 6 3 8. *. 3. 02 2.1. *. 2. 3 817.. *. 3. 0 6 8 8. *. M-SUB-Q
  • 2

Catawba 2 Cycle 7 Core Operating Limits Report '

Page 52 of 144 i

' Appendix A l

TABLE 1 (CONTINUED)

F-SUB-Q G M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION s

AT ' 7 5% POWER, 415 EFPD, THIS IS LEVEL 6 OF 18 I

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BO7 TON)

('

H G

F E

D C

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...s Beeeeeeeeeeeeeen 8

  • 1.1310
  • 1.5594
  • 1.3902
  • 1.5904 *'1.2209-* 1.4116
  • 1.2349
  • 1.0978
  • t l
  • 2. 0853
  • 1.5205
  • 1.6917..*.1 4820..*.1. 8939.*.1. 6364.'*.1 8481.*. 2. 0501.*

eeeeeeeeeeeeeeeeee......

... e 9

  • 1.5594
  • 1.2480
  • 1.5947
  • 1.2805
  • 1.5508
  • 1.3109
  • 1.3227
  • 8193 *
  • '1.5205 *-1.8768
  • 1.4821
  • 1.7023
  • 1.5131
  • 1.7672
  • 1.7352
  • 2.7420
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.3902
  • 1.5947
  • 1.3912
  • 1.5819
  • 1.3462
  • 1.4105
  • 1.1963
  • 1.0496 *'
  • 1.6917
  • 1.4829
  • 1.6915
  • 1.4941
  • 1.1405
  • 1.6561
  • 1.9227
  • 2.1487
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.5904 1.3794
  • 1.5819
  • 1.2263
  • 1.5176
  • 1.2541
  • 1.2509
  • 8225 *
  • 1.4820
  • 1.7023
  • 1.4941
  • 1.9131
  • 1.5597
  • 1.8759
  • 1.8537
  • 2.7555
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1. 22 09
  • 1. 5 540
  • 1. 3 473 * ~ 1. 5187
  • 1. 282 0
  • 1. 3 23 8
  • 1. 053 9
  • l ee e e e e e e e e e e e ee eee eee e e e ee e e eee ee e e ee e e 8608.*.1.e.7 966
  • 2.2155
  • 1.8939
  • 1.5092
  • 1.7395
  • 1.5589
  • 1.....

eeeeeeeeeeee se 13

  • 1.4116
  • 1.3109
  • 1.4105
  • 1.2541
  • 1.3248
  • 1.1642 *

.7197.*

i

  • 1.6364
  • 1.7664
  • 1.6561
  • 1.8746
  • 1.7955
  • 2.0369
  • 3.2333
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2349 *'1.3216
  • 1.1952
  • 1.2499
  • 1.0549 *

.7272'*

  • 1.8481
  • 1.7362
  • 1.9240
  • 1.8549
  • 2.2138
  • 3.1982
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.0978 *:.8182
  • 1.0485 *.8215
  • 2.0501
  • 2.74 M-SUB-Q t

e e e e e e e e e e e e e s e.41...*.2.

1503

  • 2.7 608.*e eeeeeeeee...

i AT 75% POWER, 415 BFPD, 'THIS Z8 LEVEL-- 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

U G

F E

D C

.B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1652
  • 1.6108
  • 1.4309'* 1.6429
  • 1.2563
  • 1.4555
  • 1.2702
  • 1.1320 *
  • 1.8093
  • 1.3244
  • 1.48 1

. 1.6705

  • 1.4415
  • 1.6330
  • 1.8112
  • l ee e e ee eee e e e e e e e ee e e e ee.57..*ee ee.2 992
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese

.9

  • 1.6108
  • 1.2863
  • 1.6472
  • 1.4201
  • 1.6011
  • 1.3484
  • 1.3623
  • 8429
  • i
  • 1.3244
  • 1.6444
  • 1.2976
  • 1.4962
  • 1.3272 = 1.5566
  • 1.5291
  • 2.4251 *

^

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.4309
  • 1.6461
  • 1.4319
  • 1.6322
  • 1.3848
  • 1.4544
  • 1.2306
  • 1.0006
  • l

. 1. 4857..*.1. 2976

  • 1.4857.*ee. 3079.e*e.1. 5287..*. 1. 4517
  • 1. 6918 *e.e.8960
  • 1 1.

.ee.

1

...eeee.eee ee

..ee..

..e.

l' 11

  • 1.6429
  • 1.4201
  • 1.6333
  • 1.2616
  • 1.5679
  • 1.2906
  • 1.2906
  • 8472
  • j
  • 1.2992
  • 1.4970
  • 1.3079
  • 1. 6750 *.... 1. 3587.*. 1 6359.* 1. 62.18..*. 2. 4271..*

assassaeaeeeee...............

l 12

  • 1.2002
  • 1.CG44
  • 1.355; a 1.567G
  • 1.3205
  • 1.3655
  • 1.0871
  • f
  • 1 6705
  • 1.32.53
  • 1.5278
  • 1.3580..*. 1. 6076
  • 1. 5511.*. 1. 9257
  • e.e

..eeeen eeeeeeeeeeeeeeeeee

.ee.

eee.

13

  • 1.4555
  • 1.3484
  • 1.4544
  • 1.2916
  • 1.3666
  • 1.2027 *

.7422 *

  • 1.4415
  • 1.5565
  • 1.4517
  • 1.6351
  • 1.5496
  • 1.7555
  • 2.7996
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 14
  • 1.2702
  • 1.3612
  • 1.2295
  • 1.2895
  • 1.0883. * -.7508
  • e.1. 6 3 3 0.. *. 1. 52 9 9. *. 1. 6. 9 3 0.. *. 1 62 27.. *. 1. 9 2 3 4. *. 2. 7 7 0 6. *.

15

  • 1.1320 *

.8429

  • 1.0806 *

.8461

  • 1.8112
  • 2.4271
  • 1.8972
  • 2.4295
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

L

+-.

m.-

v

Catawba 2 Cycle 7 Core Operating Limits Report Page 53 of 144 Appendix A TABLE 1 - (CONTINUED).

F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION.

AT 75% POWER, 415 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D-C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1556
  • 1.6033
  • 1.4244
  • 1.6354
  • 1.2499
  • 1.4512
  • 1.2681
  • 1.1278
  • 1.5509
  • 1.3366
  • 1.5147
  • 1.6828
  • e.1 6779
  • 1 2251.*.1. 3765.*. 1 2038 *

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6033
  • 1.2798
  • 1.6397
  • 1.4137
  • 1.5947
  • 1.3441
  • 1.3612 *

.8375 *

  • 1.2251
  • 1.5237
  • 1 2.019
  • 1.3867
  • 1.2301
  • 1.4.424.*ee 4148..*. 2. 2625.*

1 eeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.4244
  • 1.6397
  • 1.4255
  • 1.6258
  • 1.3784
  • 1.4512'* 1.2263
  • 1.0753 *
  • 1.3765
  • 1.2019
  • 1.3757
  • 1.2107
  • 1.4163
  • 1.3416
  • 1.5682
  • 1.7635 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.6354
  • 1.4137
  • 1.6268
  • 1.2563
  • 1.5615
  • 1.2852
  • 1.2873 *

.8397 *

~

e e e e e e e e e e.1. 3 87 4

  • 1. 2107
  • 1. 5 4 9 6. *. 1. e. 2 512
  • 1. e. 5107
  • 1. 4 9 8 0
  • 2. 2 6 2 2. *
  • 1.2038 *

.eeeeeeeeeeeeeeeeeeeeeee eeeeeee eeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2499
  • 1.5969
  • 1.3794
  • 1.5626
  • 1.3152
  • 1.3645
  • 1.0828
  • eee 5.509.*. 1. 2281 *.1 4150
  • 1.e.2.ee..*.1. 4798
  • 1 4233
  • 1.7771.*
  • 1 506 e.

....eee

. eeeee.

.eeeeee 13

  • 1.4512
  • 1.3452
  • 1.4512
  • 1.2863
  • 1.3655
  • 1.2006 *

.7368

  • eeeeeeeeeeeeeeeeee
1. 3416
  • 1.5099
  • 1.4220
  • 1.6116
  • 2.5881 *
  • 1.3366
  • 1.4417 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2681
  • 1.3602
  • 1.2252
  • 1.2873
  • 1.0839 *

-.7454 *

  • 1. 5147..*.1. 4161.*. 1 5691.*. 1. 4986.*.1 7749
  • 2.5610
  • e.

.ee.

    • eeeeeeeeeeee 15
  • 1.1278 *

.8375

  • 1.0753 *

.8386

  • 1.6828
  • 2.2640
  • 1.7648
  • 2.2 eeeeeeeeeeeeeeeeeeeeeeeeeee.**ee.640.* M-SUB-Q AT 75% POWER, 415 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTON) e............O........F.......ee.........D.........C.........B.........A......

H E

8

  • 1.1535
  • 1.6033
  • 1.4255
  • 1.6365
  • 1.2563
  • 1.4608
  • 1.2841
  • 1.1395 *
  • 1. 5812..*.1. 1496.*.1. 2939..*. 1 1308.*. 1 4525.*.1. 2507..*.1. 408.4.*. 1 5718.*

e.

p

  • 1.6033
  • 1.2831
  • 1.6408
  • 1.4148
  • 1.5958'* 1.3559
  • 1.3762
  • 8482 *

. 1. 1.496 *.... 1. 42 9 8. *. 1. 12 9 6.. *. 1. 3 0 3 5.. *. 1. 15 5 8. *.1.

3 4 51.. *. 1 318 2. *. 2. 110 0.. *e e.

10

  • 1.4255
  • 1.6397
  • 1.4276
  • 1.6247
  • 1.3827
  • 1.4619
  • 1.2391
  • 1.0828
  • e.1. 2 9 3 9
  • 1.13 0 5
  • 1. 2 915
  • 1 13 91.. *. 1. 3 27 3.. *.1.2 5 27.. *.1.4 614. *. 1. 6. 5 3 3.. *.

eeeeee**eeeeeeeeeeeeeeee 11

  • 1.6365
  • 1.4148
  • 1.6247
  • 1.2616
  • 1.5690
  • 1.2948
  • 1.2901 *

.8439

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 7.e*eee.1695
  • 1.4088
  • 1.3970
  • 2.1234 *
  • 1.1308
  • 1.3035
  • 1.1390
  • 1.449 1

e eeeeeeeeeeeeeeeeeeeeeeeeeee**eeen 12

  • 1.2563
  • 1.5990
  • 1.3837
  • 1.5690
  • 1.3238
  • 1.3773
  • 1.0946'*
  • eeeeeeeeeeeeeeeeeeeeeeee... 1. 1686
  • 1.3798
  • 1.3230
  • 1.6527 *
  • 1.4525
  • 1.1536
  • 1.3261 *

+eee***eeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4608
  • 1.3570
  • 1.4619
  • 1.2959
  • 1.3784
  • 1.2145 *

.7465 *

  • 1. 2507..*.1. 3444.*.1. 2523..*.1. 4081..*.1. 3218.*. 1. 4950..*. 2. 4029..*.

e.

ee ee 14

  • 1.2841
  • 1.3752
  • 1.2381
  • 1.2981
  • 1.0956 *

.7551

  • e.1. 4 0 8 4. *.1.319 2.. *. 1. e. 4 6 2 3.. *. 1 3 9 7 6.. *. 1. 6. 5 0 0. *. 2. 3 7 7 9.. *.

e.

. ee 15

  • 1.1395 *

.8472

  • 1.0817 *

.8439

  • 1.5718
  • 2.1115
  • 1. 6542
  • 2.1249.*. N-SUB-Q e.eeeeeeeeeeeeeeeeee eeeeeee...

I t

l' l

I i

t

Catawba 2 Cycle ? Core Operating Limits Report.

Page 54 of 146 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGAN) - NORMAL OPERATION AT 75% POWER, 415 EFFD,. THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

G F

A e...H...eeeeeeeeeeeeeee.........B......... D......... C......... B....... e e e e e e e.

8* 1.0464

  • 1.4394
  • 1.2895
  • 1.4748
  • 1.1556
  • 1.3484
  • 1.2001'* 1.0517 *
  • 1 1.4358
  • 1.6364
  • e.. 6669.*.1 2233..*. 1. 3678.*.1. 1971..*. 1.5105
  • 1.2954
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

.9

  • 1.4394
  • 1.1695
  • 1.4769
  • 1.2788
  • 1.4448
  • 1.2595
  • 1.2777 *-.8011 *
  • 1. 2 2 3 3.. *.1.4 9 9 6. *.1.19 7 3.. *. 1. 37 87.. *. 1. 216 6. *. 1. 3 8 62...*.1.

3 6 07.. *. 2. 14. 43.. * -

10

  • 1.2895
  • 1.4758
  • 1.2927
  • 1.4651
  • 1.2616
  • 1.3473
  • 1.1578

.9896 *

  • 1. 3 67 8. *.1 19 8 3. *.1.3 6. 4 6.*. e * *. 2 0 3 4. *. 1. 3 912.. *.1 3 0 0 0.. *.1.

5 0 0 0. *.1.7 3 6 8..

  • l 1

..e**e e

11

  • 1.4748
  • 1.2788
  • 1.4662
  • 1.1599 *'1'.4244
  • 1.1952
  • 1.1931 *

.7765

  • 4 l

. 1. 1971.*. 1 3787..*. 1. 2028.*.1. 5090.*.1. 2.313..*.1. 4611..*. 1. 4548..*. 2. 2162..*.

I 12

  • 1.1556
  • 1.4501
  • 1.2638
  • 1.4255
  • 1.2145
  • 1.2702
  • 1.0196 *

. 1. 510 5.

  • e e e. 2121
  • 1. 3 8 9 4
  • 1. 2 3. 07.. *.- 1. 4 3 8 3.. *.1.

3 7 2 9. *. 1. 7 0 0 9

  • e

]

1 eeeeeeeeeeeeeeeeeee 13

  • 1.3484
  • 1.2606
  • 1.3484
  • 1.1952
  • 1.2713
  • 1.1278 *

.7036

  • j
  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e 3..*.1. 3 716.*. 1. 5 416.*. 2. 4 471..*.
  • 1.2954
  • 1.3855
  • 1.2994
  • 1.460 14
  • 1.2081
  • 1.2766
  • 1.1567
  • 1.1931
  • 1.0207 *

.7111 *

  • 1. 4358.*.1. 3614.*.1. 5008.*. 1. 4554.*.1. 6989..*.2. 4209.*.

15

  • 1.0517 *

.8011 *

.9896 *

.7754

  • 1. 63 6 4.*. 2. 1456.*. 1. 7 37 6.e *e e e e.2183.* M-SUB-Q 2

j e...

l AT 75% POWER, 415 EFPD, THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

I

....H.........G.........F.........E.e.......D........C.........B.........A......

l;'

8*

.7283'*

.6587 *

.8632 *

.6844 *

.8086 *

.9639 *. 8771 *

.7165 *

-. 2. e. 3 0 9 6. *. 2. 5 6 2 4.. *. 1. 9 6 8 4.

  • e e e. 4716.. *.2 0 8 2 8. *. 1 7 5 0 6. *.1.

9 2 0 3. *.2.

3 3 6 8 *

...., 2 e

    • e.

9 *-.6587 *

.8032 *

.6833 *

.8611 *

.6929 *

.8954 *

.9243 *

.5858

  • e 2.5624..*. 2. 1049
  • 2.4758
  • 1.9735.*.eee.4316
  • 1.8888.*.1. 0227
  • 2.8562
  • 2 ee.

eeeeeeeeeeeeee.**ee.

eeeeeeeeeee.

eeeeeeeeeeeeeen 10 *

.8632 *

.6833 *

.8654 *

.6833 * -.8718 *

.9628 *

.8257 *

.4252 *

  • 1. 9684
  • 2. 4758.*. 1. 9644.*. 2. 4754..*.1 9428
  • 1. 7580.*.2. 0411..*. 3. 9.043.*.

11 *

.6844 *

.8611

  • 6833 *-.8075 *

.6747 *

.8407 *

.8332 *

.5494 *

  • 2. 4716
  • 1. 9735.*.2. 4729
  • 2. 0861..*. 2. 4931.*eeee.0083
  • 2.0199.*.3. 0412..*

2 e.

ee..

eeeeeeeeeee...

l_

12 *

.8086 *

.6940 *

.8729 *

.6758 *

.8354 *

.8857 *

.7165 *

  • e. 0828
  • 2.4239
  • 1.9399
  • 2.4909.*. 2. 0181.*.1. 9041..*.2. 3482..*
  • 2

...eeeeeeeeeeeeeeeeeeeeeee...

13 *

.9639 *

.8954 *

.9628 *

.8418 *

.8868 *

.7883 *

.5023

  • I l
  • 1. 7506
  • 1. 8866
  • 1.7571..*. 2. 0069.*. 1. 9016..*. 2. 140.4.*. 3.3338 *

..eeeeee.

ee.

eeeeeee.

l 14 *

.8771 *

.9231 *

.8257 *

.8332 *

.7186 *

.5087

  • e.1. 9203
  • 1. 8239..*.2. 0.413..*. 2 0199..*. 2. 3444
  • 3. 2927..*.

15 *

.7165 *

.5858 *

.4252 *

.5484

  • 2. 3368.*. 2. 8562.e*.3. 9053..*.eee.0445
  • M-SUB-Q 3

ee eeeee.

l.

i i

1 l

~

t:

.i l

Catawba 2 Cycle 7 Core Operating Limits Report.

Page 55 of 144 l

Appendix A 1

TABLE 1 - (CONTINUED) f j

I F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 50% POWER, 4 EFPD, THIS IS LEVEL 18 OF 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

G F

E D

C.

B

'A

  • ee.H.......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.3192 *

.2731.*

.5623 *

.3534 *

.5858 *

.7079

  • 6694 *

.5141 *

  • 4.6959
  • 6.5335
  • 3.4602
  • 5.51...6 9. *.3. 3 42 9.*.2. 7 6 57.. *. 2. 9 410.
  • e e e. 8 02 0
  • 3 eeeeee e eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9*

.2731 *

.4937 *

.3363 *

.5976 *

.3898 *

.6683 *' 6812 *

.4455 *

. 6. 53 3 5.*.3. 8.437..*.5 6 8 5 9.* e e e.177 9

  • 4. 877 4
  • 2.9273
  • 2. 8 506
  • 4 3 82 9.*.

3 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

10 *

.5623 *

.3363 *

.5751 *

.3502'*'.6180 *

.6640

  • 6003 *

.2420 *

  • 3.4602
  • 5.6859
  • 3.270
  • eeeeee...eeeeeeeeeeeeee.1
  • 5.2859
  • 3.0431
  • 2.8050..*. 3. 1121
  • 7.7345 *
  • eeeeeeeeeeeeeeeeeeeeeeee..

.. eeeeeeeeeee.

11 *

.3534 *

.6019 *

.3513 *

.5323 *

.3309 *

.5537

  • 5390 *

.3856

  • e.5 5169
  • 3.1652
  • 5.2682
  • 3.1811
  • 4.8400
  • 3.0227
  • 3.1843
  • 4.6820 *

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 12 *

.5858 *

.3920'*

.6212 *

.3320 *

.4391 *

.4584 4338 *

  • 3.3429
  • 4.8474
  • 3.0285
  • 4.8252
  • 2.9912
  • 2.9799
  • 3.5819
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13 *

.7079 *

.6694 *

.6662 * ~.5558 *

.4616 *

'.3770

  • 2677'*

e.2. 7 6 57.. *.2.916 5.*.2. 7 9 51

  • 3. 0111...*.2.9 6 8 6.*.3. 2 4 6 6.*.5 2 9 47..*.

...eeeeee..

14 *

.6694 *

.6822 *

.6105 *

.5419 *

.4370 *

.2742 *

  • 2.9410
  • 2.8481
  • 3.1060
  • 3.1715
  • 3.5617
  • 5.1732
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.5141 *

.4455 *

.2431 *.. 3866

  • 3.8020
  • 4.3829
  • 7.7156
  • 4.6681 *
  • eeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeee. M-8UB-Q I

AT 50% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOW)'

A

....H.........G.........F.........E.ee......D........'.C......e**B-eeeeeeeeee**eee 8 *

.4595 *

.8279 *

.8782'*

.9939 * ' '.8675 *.9885

  • 1.0164 *

'8602 *

  • 4.0092
  • 2.8326
  • 2.0038
  • 2.4925
  • 2.8557
  • 2.5022
  • 2.4436
  • 2.9095

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9*

.8279 *

.7454 *

.9575 *

.9211

  • 1.0282
  • 1.0217
  • 9982 *

.6779

  • e 2. 8 3 2 6.*.3. 19 3 4.*. 2. 5 417
  • 2. 6 4 81
  • 2. 3 3 0 0.* 2. 3 9 0 6
  • 2. 4 4 51
  • 3. 6 3 5 5 *

.eeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeeee.

10 *

.8782 *

.9585 *

.9168 *

.9778 *

.9425 * '.9478

  • 9296 *

.7294 *

  • 2 8038
  • 2.5384
  • 2.6229
  • 2.4025
  • 2. 4861
  • 2.5169 *-2.5501
  • 3. 2472..*.-

[

  • ee....eeeeeeeeeeeeeeeeeeeeeee eeeeee

..eeeeeeeeeeeeeeeeeeeeee.

11 *

.9939 *

.9253 *

.9821 *

.7904 *

.9189 *

'8525 *

.8439 *

.5998

  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.7 6.. *. 2. 3 3 4 3.. *.2.

5 0 5 4.

  • 2. 5 5 8 6.. *.3.

818 9 *

  • 2.4925
  • 2.6390
  • 2.3981
  • 2.77 eeeeee 12 *

.8675

  • 1.0378 *

.9478 *

.9232 *

.6255 *.7229

  • 6972 *
  • 2. 85. 57..*. 2. 317 5
  • 2. 47 49
  • 2.3 2.5 8.*. 2. 432 8 e *e e e e. 4 5 45
  • 2. 83 0 9 * '

2 eeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeee.

l 13 *

.9885

  • 1.0249 *

.9510 *

.8557 *

.7272 *

.6094

  • 4134
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.57..*.2. 4467
  • 2.5552
  • 4.3774 *
  • 2.5022
  • 2.3833 8 2.5038
  • 2.49

..eeeeeeeeeeeeeeeeeeee.

l 14

  • 1.0164
  • 1.0003 *

.9328 *

.8472 *

.7015 *

.4241 *

  • 2. 4436.*. 2. 4405.*.2. 5417..*. 2. 5484..*.2. 8223
  • 4.2662
  • l e.

.eeeeeeeeeeee.

15

  • 8482 *

.6769 *

.7315 *

.6030

  • 3.2390.* 3.8038
  • N-SUB-Q e 2.9095
  • 3.6389 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l.

1 e+--,

se

. - ~.

l Catawba 2 Cycle 7 Core Operating Limits Report.

Page 56 of 144 Appendix A I

TABLE 1 (CORTINUFO)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTON) 6

....H.........G.........F......**E-ee.....ee.........C.........B.......A.....e D

l I

8*

.6008

  • 1.1042
  • 1.1588
  • 1.2959
  • 1.0892
  • 1.2124
  • 1.2316
  • 1.0614
  • 2

. 3. 4638..*eeee.3695

  • 2.3640
  • 2.1259
  • 2.5217
  • 2.2714
  • 2.2442
  • 2.5885
  • l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.1042 *

.9714

  • 1.2702
  • 1.2038
  • 1.2927
  • 1.2434
  • 1.2295 *

.8161

  • l
  • 2. 3695.*. 2. 7209.*.2. 1325..*.2. 2602..*.2. 0579..*. 2. 1696.*. 2. 2092'* 3.3505 *

)

eee eeeeeeeeeeeeen 10

  • 1.1588-* 1.2723
  • 1.2102
  • 1.2798
  • 1.1920
  • 1.1963 *-1.143t *

.9339 *

  • 2. 3640..*. 2. 1292..*. 2. 2187..*.2. 0517..*. 2. 1916..*. 2. 2164.*. 2. 3096.*.2. 8287..*

e.

e..

1.2092

  • 1.2863
  • 1.0185
  • 1.1877
  • 1.0656
  • 1.0614 *

.7572

  • 11
  • 1.2959
  • 2.1259
  • 2.2515
  • 2.0476
  • 2.4261
  • 2.0385
  • 2.2320
  • 2.2664
  • 3.3819
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

12

  • 1.0892
  • 1.3013
  • 1.1995
  • 1.1920 *

.8150 *..9232 *

.8729

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 2.e.1515
  • 2.1616
  • 2.5465 *
  • 2.5217
  • 2.0466
  • 2.1823
  • 2.0375
  • eeeeeeeeeeeeeeeeeeeeeeee i

13

  • 1.2124
  • 1.2477
  • 1.2027
  • 1.0710 *

.9286 *

.7786 *-.5034 *

  • 2.2714
  • 2.1594
  • 2.2057
  • 2.2235.*. 2. 1537..*. 2. 2789.*.4. 0372..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2316
  • 1.2327
  • 1.1470
  • 1.0667 *

.8782 *

.5173 *

. 2. 2442.*. 2. 2045.*.2. 3032..*. 2. 2552..*.2. 5328..*.3. 9288..*.

15

  • 1.0614 *

.8150 *

.9361 *

.7 604

  • 2.5885
  • 3.3533
  • 2. 8210
  • 3.3653.*. M-SUB-Q eeeeeeeeeeeeeeeeee..

eeeeeeeeee...

I 1

l AT 50% FOWER, 4 EFPD, THIS Is LEVEL 15 OF 18 (LEVRL 18 e TOP OF CORE, LEVEL 1 m BOTTOM)-

e e e e e e... e...G......e * *F..... e e e e e e e e e e e e e' e e e e e e e e e e

.....B........ A......

l H

E D

C ee

.7026

  • 1.3023
  • 1.3570
  • 1.5112
  • 1.2499
  • 1.3827
  • 1.3966
  • 1.2113
  • 8 *
  • 3. 18 9 7.. *.2.16 2 4. *..' 2. 16 8. 0. *. 1. 9 5 9 5. *. 2. 3 4 61..*. 2. 13 91. *. 2. 1271.. *. 2. e. 43 7 4
  • e.

eeeeee 1.3023

  • 1.1320
  • 1.4940
  • 1.4009
  • 1.4983
  • 1.4191
  • 1.4073 *

.9189

  • 9
  • e 2.1624
  • 2.4963
  • 1.9485
  • 2.0888
  • 1.9164
  • 2.0419
  • 2.0764
  • 3.1774
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3570
  • 1.4973
  • 1.4148
  • 1.4951
  • 1.3816'* 1.3805
  • 1.3045
  • 1.0742 *
  • 2. 1610. *.1. 9 4 5 8. *.2.0 4 2 9.. *. 1. 8 9 3 8. *.2.

0 4 5 9.. *.2.

0 6 2 0 *

  • e e 18 0 4. *. 2. 6 4 91..
  • 2...

3 11 a 1.5112

  • 1.4073
  • 1.5037
  • 1.1824
  • 1.3902
  • 1.2284
  • 1.2274 *

.8675 *

  • 1. 9 5 9 5.
  • 2. 0 8 0 5.*.1. 8 8 8 5.*.2. 2 5 52..*. 1. 8 9 0 4. *.2.

0 9 3 0..*. 2. 119 6

  • 3.10 4 2..*e eeeeeeeeeee

~

12

  • 1.2499
  • 1.5112
  • 1.3891
  • 1.3955 *

.9489

  • 1.0753
  • 1.0067
  • eeeeeeeeeeeeeeeeeeeeeeeeeee. 1. 8878
  • 2.0172..*.2.e.0172
  • 2.3996 *
  • 2.3461
  • 1.9050
  • 2.0359
  • eeeeeeeeeeee.

eeeeeeeeeeeeee.

13

  • 1.3827
  • 1.4266
  • 1.3891
  • 1.2349
  • 1.0817 *

.9082 *

.5751 *

  • 2. 1391..*.2. 0310..*. 2. 0529
  • 2.0...836.*.2. 0095.*. 2. 1413..*.3. 8347..*.

l

.. eeeeee.

14

  • 1.3966
  • 1.4105
  • 1.3098
  • 1.2338
  • 1.0132 *

.5901 *

  • 2. 12 71.. *. 2. 07 2 3.. *.2.

17 2 5.. *. 2. e.10 8 9.. *. 2. 3 8 3 2.. *. 3. 7 3 0 9.. *.

e.

e.

l 15

  • 1.2113 *

.9189

  • 1.0774 *

.8718

  • 2,4374
  • 3 1799
  • 2.6424
  • 3.1697
  • M-sUB-Q eeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeee

(

l r

i' Catawba 2 Cycle 7 Core Operating Limits Report Page 57 of 144 1

Appendix A l

TABLE 1 (CONTINUED) i F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 4 EFPD, THIS IS LEVEL 14 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 e BOTTOM) i e............G.........F.........B.........D.........C.........B.........A......

H 1.6215

  • 1.3280
  • 1.4748
  • 1.4769
  • 1.2841
  • 8*

.7551

  • 1.4073
  • 1.4566 *
  • ee 240.0.*eee.1876
  • 2.2035
  • 1.9913
  • 2.3951
  • 2.1887
  • 2.1933
  • 2.5101 *
  • 3 2

e.

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9

  • 1.4073
  • 1.2124
  • 1.6119
  • 1.4994
  • 1.6119
  • 1.5090
  • 1.4973 *

.9682 *

  • 2.1876
  • 2.531
  • 1.9737
  • 2.1326
  • 1.9537
  • 2.0988
  • 2.1315
  • 3.2757..*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

e 10

  • 1.4566
  • 1.6140
  • 1.5155
  • 1.6129
  • 1.4791
  • 1.4801
  • 1.3859
  • 1.1428 *
  • 2. 2035.a. 1 97.10..*.2. 0844.*. 1 9262..*. 2. 0967..*. 2. 1051.*.2. 2467..*.2. 7264.*

e.

11

  • 1.6215
  • 1.5048
  • 1.6194
  • 1.2670
  • 1.5015
  • 1.3163
  • 1.3184 *

.9221

  • 1.9913
  • 2.1240
  • 1.9210
  • 2.2987
  • 1.9262
  • 2.1499
  • 2.1753
  • 3.2916
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.3280
  • 1.6215
  • 1.4876
  • 1.5080
  • 1.0239
  • 1.1631
  • 1.0006
  • e.2 e. 3 9 51.*.1. 9 4 3 0.. *. 2. 0 8 6 4. *.1.

9 2 01.*.2. 07 52.. *.2.0 671.*.2. 47 3 5.

  • e..

ee.

.e 1.5176

  • 1.4887
  • 1.3238
  • 1.1706 *

.9832 *

.6169

  • 13
  • 1.4748 *
  • 2.1887..*.2. 0874.*.2. 0957..*. 2. 1401
  • 2.0580
  • 2.2047
  • 3.9563
  • e...

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.4769
  • 1.5015
  • 1.3912
  • 1.3248
  • 1.0892 *

.6340

  • 2.1933
  • 2.1272
  • 2.2396
  • 2.1642
  • 2.4563
  • 3.8468
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.2841 *

.9671

  • 1.1460 *

.9264

. 2. 5101. *.3. 27 82.*. 2. 7177...*.3 273 8.*. M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 13 CF 18 (LEVEL 18 = TO7 OF CORB, LEVEL 1 = BOTTOM)

H G

F D

C B

A e eeeeeeeeeeeeeeeeeeeeee....ee.E...... ee......eeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.8290

  • 1.5422
  • 1.5915
  • 1.7650
  • 1.4416
  • 1.6001
  • 1.6001
  • 1.3923
  • 2 e. 3 2 8 8 5..*. 2. 2 2. 5 3.*.
2. 2 415.*. 2. 0 3 0 0. *.2.4 3 5 5. *.2.2 3 8 0..*.2.

2 4 6 2..*. e e e. 5 6 6 5

  • eeeee.

9

  • 1.5422
  • 1.3259
  • 1.7618
  • 1.6343
  • 1.',618
  • 1.6429
  • 1.6268
  • 1.0464 *
  • 2. 2253.*. 2. 5662..*. 2. 0082..*.2. 1947..*. 1. 9905.*.2. 1464.*. 2. 1791.*.3. 3400.*.

e.

10

  • 1.5915
  • 1.7639
  • 1.6558
  • 1.7629
  • 1.6172
  • 1.6151
  • 1.5090
  • 1.2434 *

. 2. 2415..*. 2. 0054 *... 2. 12 5 2.. *. 1. 9 6 5 0.. *. 2. 14 2 2.. *. 2. 14 9 7..*. 2. 3 015. *. 2. 7 87 7.. *.

1.6397

  • 1.7693
  • 1.3912
  • 1.6547
  • 1.4512
  • 1.4533
  • 1.0057
  • 11
  • 1.7650
  • e.2. 0300..*.2. 1659.*.1 9588.**2.3367.*.1. 9650
  • 2.1980
  • 2.2218
  • 3.3737 *
  • e

..e********eeeeeeeeeeeee*eeeeeen 12

  • 1.441G
  • 1.7714
  • 1.6268
  • 1.6622
  • 1.1374
  • 1.3013
  • 1.2017 *
  • 2. 4 3 5 5. *. 1. 9 7 9 5.. *. 2. 13 0 5. *.1.

9 5 8 8.. *. 2. 12. 4 2.. *. e e e.1117

  • 2. 5 318
  • 2 e.

eeeeeeeeeeeeee.

13

  • 1.6001
  • 1.6515
  • 1.6258
  • 1.4598
  • 1.3098
  • 1.1117 *

.6908

  • e.2 2380
  • 2.1347..*. 2. 1390..... 2. 1879.*. 2. 1024.*. 2. 2533..*. 4. 0365.*

.....ee...

14

  • 1.6001
  • 1.6311
  • 1.5155
  • 1.4608
  • 1.2102 *

.7101

  • e.2. 2 4 6 2.. *. 2. 17 47.*.
2. 2 9 2 9. *.2.210 4
  • 2. G14 0
  • 3.9272 *

.eeeeeeeeeeeeeeeenesee

1. 0 4 53
  • 1. 2 477
  • 1. 0110
  • 1.3923 *
    • e 5665
  • 3.3434
  • 2.7805
  • 3.3579 M-SUB-Q
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeee w------- - - - - - - -

(-

)

l i

Catawba 2 Cycle 7 Core Operating Linsits Report Page 58 of 144 Appendix A TABLE 1 (CONTINUED) k F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION f

AT 50% POWER, 4 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) 3 i.

H G

F B

D

.C B

A i

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8 *

.9125

  • 1.6290
  • 1.6611
  • 1.8400
  • 1.4962
  • 1.6643 + 1.6579
  • 1.4426
  • l 4

2.359 7...*.2.3 8 4 4

  • 2.15 6 5.. *. 2. 6 0 0 9.. *. 2. 3 8 0 4. *. 2 3..... e e.909
  • 2 7179..*
  • 3.5088 *

<f eeeeeeeeee**ee.

. e**eeee.

I 9

  • 1.6290
  • 1.3891
  • 1.8453
  • 1.7050
  • 1.8464
  • 1.7115
  • 1.6933
  • 1.0817 *

. 2. 3 5 9 7.. *. 2. 7 3 51..*.2.

13 52..*.2. e. 3 2 0 5.*.2.

12 0 6.*.2. 2 9 47..* 2. 3 2 0 5 * - 3. 5 618.. *e 10

  • 1.6611
  • 1.8475
  • 1.7286
  • 1.8464
  • 1.6943
  • 1.6933
  • 1.5754
  • 1.2959
2. 13 21.. *.2.2 718. *.2. 0 9. 6 0..*. 2. 2 9 3 5.*.
2. 2. 9 5. 9. *.2.

4 6 4 4.. *. 2. 97 7 6...*

  • 2.3844 *
    • eeeeee...

11 *'1.8400

  • 1.7093
  • 1.8560
  • 1.4694
  • 1.7661
  • 1.5487
  • 1.5455
  • 1.0507
  • s 2

3.6224 *

  • 2.1565
  • 2.3118
  • 2.0899
  • 2.5057.*eee.0970
  • 2.3584
  • 2.3778
  • t eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee s

12

  • 1.4962
  • 1.8571
  • 1.7050
  • 1.7736
  • 1.2809
  • 1.4341
  • 1.2959 *

... 6009

  • 2. 1082..*. 2. 2802..*.2. 0899..*. 2. 2802.*.2. 2612..*.2. 7179.*.
  • 2

=

.e**e.

4 13

  • 1.
  • M4 3
  • 1.7211
  • 1. 7 0 4 0
  • 1. 5 572
  • 1. 4 42 6
  • 1.2691 *

.7561

  • l
  • 2 2826.*.2. 2850.*.2. 3456 *.. 2. 2518.*. 2. 4190.*.4. 3509.*.
  • f i

6ee ee i

is *

. 1.6975

  • 1.5808
  • 1.5540
  • 1.3055 *

.7775

  • 1

....... 2. 315 5.*. 2. 4 5 6 0. *. 2. 3 6 61.*.

2. 6 9 7 6.. *. 4. 2. 3 37..
  • eeee i

15

  • 1.4426
  • 1.0806
  • 1.3002
  • 1.0560
  • F-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeee.. 3.e.6043.* M-SUB-Q
  • 2.7179
  • 3.5648
  • 2.9674
  • 1 e...

i AT 50% POWER, 4 EFPD, THIS IS LEVEL 11 OF 18 i

(LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM) 1

....H........O.........F........E.........D.........C.een.....B.........A.ee.e.

i 8

'410

  • 1.6900
  • 1.6965'* 1.8775
  • 1.5187
  • 1.6954
  • 1.6825
  • 1.4641 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 2. 7745.*. 2 4856..*.2. 4842..*. 2. 7915.*

433

  • 2.5321
  • 2.5681
  • 2.2923
  • 1 9
  • 1.6900
  • 1.4276
  • 1.8914
  • 1.7404
  • 1.8967
  • 1.7468
  • 1.7265
  • 1.0946
  • 2.5321
  • 2.9751
  • 2.2947
  • 2.5028
  • 2.2002
  • 2.4686
  • 2.

3.7009

  • j eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.4408
  • eeeeeeeeeeeeee-d 10
  • 1.6965
  • 1.8946
  • 1.7671
  • 1.8967
  • 1.7404
  • 1.7393
  • 1.6108
  • 1.3227
  • eeeeeeee.. 2. 2911.e*eeee.4546
  • 2.2565..*.2. 4757
  • 2.4742
  • 2.6612
  • 3. 1554.*.
  • 2.5681
  • 2 t

eeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeee.

2-11

  • 1.8775
  • 1.7447
  • 1.9075
  • 1.5262
  • 1.8571
  • 1.6279
  • 1.6151
  • 1.0764 *
  • 2.2923. 8. 2.4956
  • 2.2494
  • 2.7320
  • 2.2588
  • 2.5530
  • 2.5666
  • 3 9207 *
    • eeene e***eee******eeeeeeeeeeeee*esee**********ee********

12

  • 1.5187
  • 1.9075
  • 1.7511
  • 1.6646
  • 1.5647
  • 1.6022
  • 1.3805
  • _eseeeeeeeeeeeeeeeeeeeeeeeee. 2. 2506
  • 2.4742
  • 2.4463
  • 2.9432 *
  • 2.7745
  • 2.2671
  • 2.4616 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6954
  • 1.7564
  • 1.7511
  • 1.6376
  • 1.6097
  • 1.4705 *

.8182

  • eeeeeeeeeeeee.602..*. 2. 4602..*.2. 5395
  • 2.4353
  • 2.6225
  • 4.7695 *
  • 2.4856
  • 2.4

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

a 14

  • 1.6825
  • 1.7307
  • 1.6172
  • 1.6247
  • 1.3902 *

.8418 *

)

  • 2. 4842..*.2. 4353..*eeee.6514
  • 2.5545
  • 2.9233
  • 4.6351
  • j 2

j e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese i

e J:

1 15

  • 1.4641
  • 1.0935
  • 1.3270 * -1.0817

. 2. 7 915.. *. 3. 7 0 41. *. 3. 14 6 3...*.3.

8 9 9 5. *. M-SUB-Q 1

1 i

i i

+

1 4

J i

9-

,,n

~ 1 1

4 i

Catawha 2 Cycle 7 Core Operating Limits Report Page 59 of 144 i

~ Appendix A

]

TABLE 1,(CONTINUED)

)

P-8UB-Q & M-8UB-Q VALUES (F-SUB-Q OF MARGIN) - NOhMAL OPERATION AT 50% POWER,

& EFPD,

.8 IS LEVEL 10 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM) e... H......... O........ P....... e e e e e e e e e e e e e e e e e e e e e e e e e.... B......... A..

E D

C

  • 1.7350
  • 1.5112
  • 1.1395
  • 1.7629
  • 1.7543
  • 1.9396
  • 1.5647
  • 1.7489 8
  • e.3. 9221.*.2 5666
  • 2. 5336..*.2. 2378 8'2.7358
  • 2.4491
  • 2.4504.*.2.7525 *

.eeeeeeeeeeeeeeeeeeeeeeeeeee... eeeeeee.

9

  • 1.7629
  • 1.4823
  • 1.9610 *'1.8004
  • 1.9696
  • 1.8078
  • 1.7843
  • 1.1267 *
  • 2. 5666 *...... 3. 0404.*.2. 2790.*.2. 4644.*. 2. 2600..*.2. 4339.*.2. 4096..*.3 6906.*

10

  • 1.7543
  • 1.9642
  • 1.8325
  • 1.9781
  • 1.8111
  • 1.8078
  • 1.6708
  • 1.3709
  • e. 2. 5 3 3 6.. *. 2. 2 7 5 4. *.2.
4. 57 4.. *.2.

27 5. 4. *. 2. 5 07 2.. *. 2. 4 6 8 6..*. 2. 6 5 47.. *. 3. 112 4..

  • j 11
  • 1.9396
  • 1.8046
  • 1.9813
  • 1.6033
  • 1.9610
  • 1.7232
  • 1.7040
  • 1.1181 *

.I

..... 4 5 3 2.. *.2.2 6 2 3.. *. 2. 7 9 0 6. *.2.

2 911..*. 2. 6 0 9 9. *. 2. 6 417.. *. 3. 9 5 6 5

  • 2..

. 2. 2378

  • 12
  • 1.5647
  • 1.9813
  • 1.8218
  • 1.9696
  • 1.7564
  • 1.7650
  • 1.4748 * '

. 2.7358

  • 2.2378
  • 2.4913
  • 2.2826 *e. 5291.*eee.5086
  • 3.0360
  • i 2

2...

eeeeeeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee**e e 13

  • 1.7489
  • 1.6186
  • 1.8186
  • 1.7329
  • 1.7736
  • 1.6376 *

.8846 *

  • 2 4491..*.2. 4203.*.2. 4518
  • 2.5958
  • 2. 4956.*. 2. 6976
  • 5. 0225.*.

e..

eeeeeeeeee......

14

  • 1.7350
  • 1.7886
  • 1.6772
  • 1.7136
  • 1.4865 *

.9104 *

  • 2.4504
  • 2.4029
  • 2.6465
  • 2.6273
  • 3.0128
  • 4.8750 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15 *.1.5112
  • 1.1256
  • 1.3752
  • 1.1245
  • F-SUB-Q e.2. 7 52 5..*. 3. 6 9 3 8. *.3.

10 57..*. 3. 9 3 8 5.

  • M-SUB-Q AT 50% POWER, 4 EFFD, THIS IS LEVEL 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) i

....H.........O.........F.........E.........D.........C.........B.........A......

1.1267

  • 1.7425
  • 1.7222
  • 1.9107
  • 1.5315
  • 1.7222
  • 1.7040
  • 1.4844
  • l 8
  • eeeeeeeeeeeeeeeeeeeeee.518.*. 2.e.1597
  • 2.6677
  • 2.3558
  • 2.3623
  • 2.6661
  • 4.0226
  • 2.5174
  • 2.4..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.7425
  • 1.4555
  • 1.9364
  • 1.7682
  • 1.9481
  • 1.7789
  • 1.7586
  • 1.1021
  • e.2. 5174 *.... 2. 9573..*.2.e.1947
  • 2.3883
  • 2.1804
  • 2.3;33 2.3205
  • 3.6043
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10
  • 1.7222
  • 1.9396
  • 1.8036
  • 1.9610
  • 1.7854 *-1.7886
  • 1.6461
  • 1.3505 *
  • 2. 4 518..*. 2. 1914.. *. 2. 3 7 91.*.2. 19 3 6. *.2.4 2 9 8..*. 2. 3 817.. *.2.

57 42..

  • e e e. 0 6 3 9
  • 3 eeeeee 11
  • 1.9107
  • 1.7736
  • 1.9653
  • 1.5904
  • 1.9546
  • 1.7168
  • 1.6975
  • 1.1021 *
  • 2*.1597
  • 2.3751
  • 2. 1815
  • 2.8446
  • 2.3218
  • 2.6563
  • 2.6809
  • 3.9207
  • 1 ee
    • e******+

e***.

..e*******e******eee******++++eeeeee***ee ********

j 12

  • 1.5315
  • 1.9589
  • 1.7971
  • 1.9631
  • 1.7650
  • 1.7821
  • 1.4748
  • e.2. 6677..*. 2. 1597..*.2. 4136.*.2. 3131
  • 2.5757
  • 2.5425
  • 3.0880
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.7222
  • 1.7896
  • 1.8004
  • 1.7265
  • 1.7907
  • 1.6558 *

.8879

  • e.. 3558
  • 2. 3444.*. 2. 3661.*. 2. 6401..*eeee.5306
  • 2.7420
  • 5.1393 *
  • 2 2

eeeeeeeeeeeeeeeeeeeeeeen 14

  • 1.7040
  • 1.7639
  • 1.6536
  • 1.7072
  • 1.4865 *

.9136

  • 2
  • 2. 3623..*. 2. 3155.e*eeee.5635
  • 3.6644
  • 3.06..39.*. 4. 9970
  • eeeeeeeeeeeeeeeeeee.

.ee 1

15

  • 1. 4 8 4 4
  • 1.1021.
  • 1.3 5 4 8
  • 1.107 4
  • 2

... 6661.*. 3. 6043..*.3. 0531.*.3 8995..*. M-SUB-Q-

Catawba 2 Cycle 7 Core Operating Limits Report Page 60 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION l

AT 50% POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

)

e...H.........G.........F.........E.........D.........C.........B.........A.......

8

  • 1.1353
  • 1.7597
  • 1.7393
  • 1.9299
  • 1.5455
  • 1.7404
  • 1.7254
  • 1.5048
  • e * *
  • e. 8 5. *. 2. 3 8 0 4...*.2.

3 2 3 0

  • 2. 0 4 5 5. *. 2. 5 2 91. *. 2. 2 2 63.. *. 2. 2 2 9 7.. *. 2. 5115.
  • 3.93..

eeeeeee..

9

  • 1.7597
  • 1.4683
  • 1.9589
  • 1.7875
  • 1.9728
  • 1.8025
  • 1.7832
  • 1.1149 *
  • 2.3804
  • 2.8005
  • 2.0769
  • 2.2635
  • 2.b660
  • 2.2240
  • 2.1914
  • 3.4006
  • eeeeee.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.7393
  • 1.9610
  • 1.8239
  • 1.9888
  • 1.8089
  • 1.8132
  • 1.6697
  • 1.3698
  • j

. 2. 3230..*. 2. 0739

  • 2.2541
  • 2.0759.*. 2. 2996..*. 2. 2529.*.2. 4326.*. 2. 8.941..*e l

eeeeeeeeeeeeeeeeee

  • e 11
  • 1.9299
  • 1.7929
  • 1.9963
  • 1.6161
  • 1.9867
  • 1.7479
  • 1.7307
  • 1.1171 *
  • 2.0455
  • 2.2541
  • 2.0640
  • 2.6893
  • 3 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee... 2. 2.483.*.2. 5958.*.2. 5696.*eee.7124
  • e eeeee.

12

  • 1.5455
  • 1.9846
  • 1.8207
  • 1.9953
  • 1.8014
  • 1.8250
  • 1.5080 *
  • 2 5291...*.2. 0.455.*. 2. 2838.*.2. 2390.*.2 5262..*. 2. 4899.*.3. 0191.*.

eee..

13

  • 1.7404
  • 1.8121
  • 1.8250
  • 1.7575
  • 1.0346
  • 1.6997 *

.9082

  • e 2 2263.*. 2. 2149.*.2. 2378.*.2. 5803.*.2. 4771...*.2. 6859.*. 5 0494.*

14

  • 1.7254
  • 1.7875
  • 1.6772
  • 1.7414
  • 1.5197 *

.9350 *

. 2. 2297..*.2. 18.59... 2 4217..*.2. 5545.*.2. 9941.*.4 9064.*

15

  • 1.5048
  • 1.1138
  • 1.3752
  • 1.1235
  • F-SUB-Q e.2. 5115.*.3. 4033.*. 2. 8844
  • 3. 6903 *. M-SUB-Q AT 50% POWER, 4 EPPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM) e...H.........O.........F.........B.........D.........C.........B.........A......

8

  • 1.0999
  • 1.7125
  • 1.6922
  • 1.8828
  • 1.5026
  • 1.6986
  • 1.6836
  • 1.4705 *
  • 3. 8205.*.2. 2814.*.2. 232.0
  • 1. 9586.*.2. 4258... 2. 1165.*. 2. 1185.*.2. 3713..*

e.

. e 9

  • 1.7125
  • 1.4255
  • 1.9107
  • 1.7393
  • 1.9267
  • 1.7575
  • 1.7425
  • 1.0849 *

. 2. 2814.*.2. 6926.*.1. 9947..*. 2. 1749.*.1 9783..*. 2. 1237..*. 2. 0849.*.3. 2235

  • eeeeee 10
  • 1.6922
  • 1.9139
  • 1.7746
  • 1.9460
  • 1.7639
  • 1.7746
  • 1.6301
  • 1.3388 *

. 2.2320... 1. 9919

  • 2.1716
  • 1.9928.*. 2. 2127..*.2. 1565.*. 2. 3230..*.2. 7386.*.

ee

.eeeeeeeeeeeeeeeee...

11

  • 1.8828
  • 1.7457
  • 1.9535
  • 1.5765
  • 1.9449
  • 1.7093
  • 1.6965
  • 1.0992 *
  • 1 e.. 9586............... 3 9810
  • 2.5942..*. 2. 1630..*.2.5218........... 4580.*. 3. 5309..*
  • 2.1662 *
  • 2

.....eeeeee.

12

  • 1.5026
  • 1.9385
  • 1.7757
  • 1.9535
  • 1.7618
  • 1.7918
  • 1.4758
  • e. 2. 42 5 8. *. 1. 9 5 8 6. *. 2. 19 81. *. 2. 15 3 3. *.2.

5 07 2.. *. 2. 4 4 91.. *. 2. 9 313.. *.

13

  • 1.6986
  • 1.7682
  • 1.7843
  • 1.7190
  • 1.8014
  • 1.6686 *

.8879 *

  • 2.1165.*. 2. 1154..*. 2.1426
  • 2.5086..*.2. 4367..*. 2. 6482..*. 4. 9176..*.

e...

eeeeeeeeeeee.

14

  • 1.6836
  • 1.7468
  • 1.6365
  • 1.7061
  • 1.4887 *

.9146

  • e.2. 1185.*.2. 0799.*.2. 3143..*. 2. 4435
  • 2.9096
  • 4.7766
  • ee.

...eeeeeeeeeeeeeeeeeeee 15

  • 1.4705
  • 1.0849
  • 1.3430
  • 1.0956
  • 2. 3 713.. *.3. 2 2 5 9.. *.2.

7 2 9 9. *. 3. 513 7..*. M-SUB-Q e.

I I

I l

i

Catawha 2 Cycle 7 Core Operating Limits Heport Page 61 of 144 Appendlix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN)

  • NORMAL OPERATION AT 50% PONER,-

4 EFPD, THIS IS LEVEL -6 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 a BOTTOM)

H O

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.0282

  • 1.6119
  • 1.5883
  • 1.7768
  • 1.4105
  • 1.6044
  • 1.5883
  • 1.3891
  • 8 *
  • 3.7316
  • 2.23
  • 2.0789
  • 2.3255
  • eeeeeeeeeeeeee.67..*.2. 1981
  • 1.9204
  • 2.3909
  • 2.0709 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.6119
  • 1.3345
  • 1.8025
  • 1.6343
  • 1.8207
  • 1.6558
  • 1.6483
  • 1.0207 *

. 2. 2367..*.2. 6547.*.1. 9533..*.2. 1.416.*. 1.9393

  • 2.0009
  • 2.0388
  • 3.1739 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10
  • 1.5883
  • 1.8057
  • 1.6675
  • 1.8400
  • 1.b611
  • 1.6793
  • 1.5358
  • 1.2627 *
  • 2.19 81..*. 1. 9 507
  • 2.13 6 3.*. 1. 9 471e *.2 16 8 4.*.2.105.e e *.2.27 42
  • 2. 6 0 09..*

1

.ee..

eeee ee

.eeeeee..

e......

1.6408

  • 1.8475
  • 1.4833
  • 1.8389
  • 1.6119
  • 1.6044
  • 1.0239
  • i 11
  • 1.7768
  • 1021.*. 2. 4546.*eee.3857
  • 3.4604.*.

2 2.5380

  • 2 e.1. 9204.*.2. 1321.*. 1. 93.58
  • eeeeeeeeeeee

.eeeeeeeeeeee.

12.* 1.4105

  • 1.8325
  • 1.6719
  • 1.8475
  • 1.6611
  • 1.6965
  • 1.3923 *
  • 2. 3909.*. 1. 9204
  • 2.1533
  • 2.0929
  • 2.4312
  • 2.3765
  • 2.8559 e.

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6044
  • 1.6654
  • 1.6890
  • 1.6215
  • 1.1061
  • 1.5765 *-.8365
  • 2.0739
  • 2.0909
  • 2.4408
  • 2.3636
  • 2.5773
  • 4.8191 *
  • 2.0709 *
  • eeee**ee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

?

14

  • 1.5883
  • 1.6526
  • 1.5433
  • 1.6140
  • 1.4041 *

.8611

  • 2.0340
  • 2.2647
  • 2.3713
  • 2.8316
  • 4.6786
  • t
  • 2.0789
  • i seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.3891
  • 1.0196
  • 1.2670
  • 1.0303

. 2. 3255.*. 3. 1762..*.2. 6727..*. 3. 4439.* M-SUB-Q

.... e AT 50% POWER, 4 EFPD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

]

H O

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 8 *

.9778

  • 1.5390
  • 1.5187
  • 1.7029
  • 1.3516
  • 1.5444
  • 1.5305
  • 1.3398 *
1..*. 1 8 610..*. 2. 316 8. *.1.9 9 9 3.. *. 2. 0 0 4 8.
  • e e e. 2 413
  • 2
  • 3.5453
  • 2.1662
  • 2.132 eeeeee eeeeeeeeeeeeeeeeeeeeeee..

9

  • 1.5390
  • 1.2745
  • 1.7254 5 1.5647
  • 1.7457.* 1.5926
  • 1.5872 *

.9821 *

  • 2. 16 6 2..*. 2. 5712.. *.1.8 910. *. 2. 07 4 9.*.1. 8 6 9 8. *e.2.

0 0 3 0..*. 1. 9 6 4 8.*.

3. 0 6 8 3. *..

10

  • 1.5187
  • 1.7286
  • 1.5969
  • 1.7661
  • 1.5958
  • 1.6140
  • 1.4780
  • 1.2156 *
  • 2.1321.*. 1.e.8878
  • 2.0670
  • 1.8787
  • 2.0869
  • 2.0254
  • 2.1848
  • 2.5003
  • eee**ee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.7029
  • 1.5722
  • 1.7736
  • 1.4244
  • 1.7650
  • 1.5497
  • 1.5444 *

.9832

  • eeeeee.9993
  • 2.3032
  • 2.2571
  • 3.3249 i

..ee......

2.0640e***ee....ee.ee...

4363

  • 1,
  • 1.8610 *
  • 1.8674 *2

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeen 12

  • 1.3516
  • 1.7575
  • 1.6065
  • 1.7736
  • 1.5379
  • 1.6343
  • 1.3409
  • l
  • 2.3168
  • 1.8570
  • 2.0729
  • 1.9910
  • 2.2996
  • 2.2448
  • 2.6826
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.5444
  • 1.6022
  • 1.6236
  • 1.5594
  • 1.6429
  • 1.5197 *

.0032 *

. 1. 9993..*. 1. 9956.*. 2. 0123..*. 2. 2898..*.2. 2332

  • 2.4353
  • 4. 5556 *-

eeeeeeeeeeeeeeee 14

  • 1.5305
  • 1.5915
  • 1.4855
  • 1.5540
  • 1.3516 *

.8279

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.. 4 4253.*e
  • 2.0048
  • 1.9595
  • 2.1760
  • 2.2529
  • 2.6595
  • 15
  • 1.3398 *

.9821

  • 1.2199 *

.9896

07 0 4. *. 2. 57 2 7.. *. 3. 3 07 2 6 N-SUB-Q eeee.

Catawba 2 Cycle 7 Core Operating Limits Report Page 62 of 144

. Appendix A TABLE 1 (CONTINUED)

F SUB-Q & H-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 50% POWER, 4 EFPD, THIS IS LEVEL 4 OF 10 s TOP OF CORE, LEVEL 1 = BOTTOM)

(LEVEL 18 e.....................F.........E........D.........C.........B.........A.....e H

O 8*

.8686

  • 1.3752
  • 1.3537 *'1.5305
  • 1.2124
  • 1.3998
  • 1.3848
  • 1.2134 *
  • 3.6840
  • 2.2413
  • 2.2297
  • 1.9341
  • 2.4163.* 2.0630
  • 2.0739
  • 2.3205
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 9
  • 1.3752
  • 1.1342
  • 1.5465
  • 1.3998
  • 1.5712
  • 1.4341
  • 1.4362 *

.8857

  • 1.9247
  • 2.0690
  • 2.0264
  • 3.1879 *

. 2. 2413..*. 2. 6793..*.1. 9639.*.2. 1651 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3537
  • 1.5497
  • 1.4266
  • 1.5904
  • 1.4330
  • 1.4566
  • 1.3334
  • 1.0956 *
  • 2. 2297..*. 1. 9612..*. 2. 1543..*.1 9419..*. 2. 1586..*. 2. 0839.*. 2. 2518.*. 2. 6694..*

e.

11

  • 1.5305
  • 1.4062
  • 1.5969
  • 1.2777
  • 1.5894
  • 1.3944
  • 1.3934 *

.8825 *

. 1.9341

  • 2.1533
  • 1.9298
  • 2.5014
  • 2.0245
  • 2.3406
  • 2.2923
  • 3.4330 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2124
  • 1.5829
  • 1.4426
  • 1.5969
  • 1.4362
  • 1.4748
  • 1.2070
  • eeeeeeeeeeeeeeeeeeeeee.

16.*. 2. 0160

  • 2.3143
  • 2.2471
  • 2.7231 *
  • 2.4163
  • 1.9111
  • 2.14 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.3996
  • 1.4426
  • 1.4651
  • 1.4019
  • 1.4823
  • 1.3698 *

.7229 *

  • 2.0630
  • 2.0611
  • 2.0699
  • 2.3255.*.2. 2355..*. 2. 4312..*.4. 5894.*e e*eeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

14

  • 1.3848
  • 1.4405
  • 1.3388
  • 1.4019
  • 1.2177 *

.7443 *

  • 2.0739
  • 2.0216
  • 2.2424
  • 2.2778
  • 2.7010
  • 4.4572
  • eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2134 *

.8857

  • 1.0988 *

.8879

  • F-SUB-Q e.2. 3 2 0 5. *.3.19 0 3..*. 2. 6 612..*. 3. 414 0..*.

M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H F

E D

C B

A e eeeeeeeee..G.....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7647

  • 1.2059
  • 1.1899
  • 1.3570
  • 1.0849
  • 1.2659
  • 1.2574
  • 1.0935 *

. 3. 8070..*. 2. 3739.*. 2. 3844.*. 2. 0572..*.2. 5470..*. 2. 1554.*. 2. 1586..*. 2. 4353.*

l 9* 1.2059

  • 1.0014
  • 1.3602
  • 1.2391
  • 1.4073
  • 1.2938
  • 1.2970 *

.8032

  • 2.0151
  • 2.1543
  • 2.1154
  • 3.3275 *
  • 2.3739.*.2. 8353
  • 2. 0980.*.2. 2996
  • eee**.

eeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10

  • 1.1899
  • 1.3623
  • 1.2584
  • 1.4116
  • 1.2809
  • 1.3023
  • 1.2017 *

.9778

  • 2.2935
  • 2.0542
  • 2.2553
  • 2.1793
  • 2.3431
  • 2.8151
  • e.2. 3844
  • 2.0950 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.3570
  • 1.2445
  • 1.4169
  • 1.1417
  • 1.4116
  • 1.2477
  • 1.2466 *

.7872 *

............ 2866

  • 2.0426..*.2 5942
  • 2. 0980
  • 2. 3949.*. 2. 3610..*.3. 6013..*.
  • 2.0572
  • 2

.e**e.......

12

  • 1.0849
  • 1.4169
  • 1.2895
  • 1.4180
  • 1.2841
  • 1.3173
  • 1.ue17 *
  • 2. 5470..*. 2. 0002..*. 2. 2390..*. 2. 0899.*. 2. 3962..*. 2. 3267..*.2. 7825.*.

e.

13

  • 1.2659
  • 1.3002
  • 1.3109
  • 1.2541
  • 1.3248
  • 1.2284 *

.6512

  • 2
  • 4.7142
  • e.2. 15 5 4. *. 2. 14 5 8. *.2.

16 51..*. 2. 3 8 0 4. *e e

e. 314 3
  • 2. 5 218 e**ee..

.....eeeeeeeee 14

  • 1.2574
  • 1.3002
  • 1.2059
  • 1.2541
  • 1.0913 *

.6715

  • e.2. 1586.*. 2. 1103.* 2.3330.*.2. 3469.*. 2. 7595..*.4 5749..*

15

  • 1.0935 *

.8022 *

.9810 *

.7915

  • 2. 4353..*.3 3300.*.2. 8060.*.3. 5805..* M-SUB-Q' h

i

. m

Catawha 2 Cycle 7 Core Operating Limits Report Page 63 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M SUB-Q VALUES (F-SUB-Q OP KAROIN) - NORMAL OPERATION AT 50% POWER, 4 EFPD.

THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

B A

e...H**.....O.........F.........E.........D.....ee..C.eeeeee.eeeeeeeeeeeeeee.

B*

.6008 *

.9189 *

.9146

  • 1.0549 *

.8739

  • 1.0453
  • 1.0507 *

.8793

  • e 4.5365
  • 2 9372
  • 2.9532
  • 2.5247..*. 3. 0065
  • 2.4927
  • 2. 4714
  • 2.9037.*

ee.eeeeee.

eeeeeeeeeeeeeeeeee.

eeeeeeeeeeeee.

eeeeeeeeeeeee e 9*

.9189 *

.7808

  • 1.0399 *

.9628

  • 1.1310
  • 1.0710
  • 1.0710 *

.6715 *

  • 2. 9372..*.3.4466.*.2. 6114..*. 2. 8187..*. 2 3778... 2. 4799.*.2. 4.435.*eee.8137.*

3 ee..

. e eeee.

10 *

.9146

  • 1.0410 *

.9693

  • 1.0978
  • 1.0282
  • 1.0507 *

.9896 *

.7668 *

(

. 2. 9532..*. 2. 6067..*.2. 8279.*. 2. 5144

  • 2. 6563.*.2.5727..*.2. 7044.*. 3. 4248.*.

.e.ee..

.... ee.

11

  • 1.0549 *

.9671

  • 1.1021 *

.9114

  • 1.1256
  • 1.0078
  • 1.0014 *

.6265 *

. 2. 5247..*. 2. 8023.*. 2. 4.999.*. 3. 0704.*.2. 4757..*. 2 7754..*.2. 7595.* 4 2980.*.

l 1.1395

  • 1.0346
  • 1.1320
  • 1.0260
  • 1.0571 *

.8761

  • l 12 *

.8739 *

  • 3.0065
  • 2. 3610..*.2. 6369
  • 2.4630
  • 2.7933
  • 2.6909
  • 3.2187
  • eeeeeeeeee.

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.0453
  • 1.0753
  • 1.0571
  • 1.0142
  • 1.0624 *

.9907 *

.5398 *

  • 2. 4 9 27.. *.2.4714.*. 2. 5 6 0 5.
  • e e 7 5 9 5. *.2.

67 6 0.*. 2. 8 9 2.1.*.5. 2 9 6 3..*.

2 e.

14

  • 1.0507
  • 1.0731 *

.9939

  • 1.0078 *

.8836 *

.5558 *

... 4714.*. 2. 4394.*.2. 6943..*.2. 7420.*. 3. 1926.*.5 1454..*.

2 15 *

.8793 *

.6715 *

.7690 *

.6297

  • 2. 9 0 3 7.. *. 3. 8171. *. 3. 414 0. *. 4 27 2 6
  • M-SUB-Q I

i AT 50% POWER, 4 EFPD, THIS IS LEVEL 1 OF 18 l

(LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

I

....H.........Q.........F.........E........D.........C........B.........A......

8*

.3748 *

.2870 *

.5344 *

.3438 *

.5516 *

.6972 *

.6469 *

.4969 *-

eeeeeeeeeeeeeeen.4.*. 4 8191.e*e.7. 3680

  • 4.5894
  • 3.e.6013
  • 3.8890
  • 4.9798
  • i
  • 6.8768
  • 8.914

.. eeeeeeeeeeeen eeeeeeeeeeeeeeeeeeeeeeee l

i 9*

.2870 *

.4745 *

.3342 *

.5773 *

.3909 *

.6469 *

.6758 *

.4145 *

  • 8
  • 4.4849
  • 6.5051
  • 3.9421
  • 3.7156
  • 5.9922
  • e.. 9144..*. 5. 422.3
  • 7. 6680

.......eeeeeesteeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10 *

.5344 *

.3342 *

.5601 *

.3599 *

.6105 *

.6854 *

.5976 *

.2356

  • 6600
  • 4.6736
  • 7.1847..*. 4 2350..*. 3. 7542..*. 4. 2895.*10.6447 *
  • 4.8191
  • 7 eeeeeeeeeeeeeeeee.

...eeeeeeee.

eeeeeeeeeeee 11 *

.3438 *

.5805 *

.3609 *

.5751 *

.3898 *

.6083 *

.5923 *

.3770 *

  • 7. 3680 *..... 4. 4 618...*.7.

14 9 2.. *. 4. 6. 6 8 5. *. 6. 7 8 0 0. *. 4 3 9 3 9..e 4., 4 4 3 3..e 6. 8768..*

e.

12 *

.5516 *

.3541 *

.6148 *

.3920 *

.603D *

.4340 *

.S119 *

  • 4.5894
  • 6.4566
  • 4.2103
  • 6.7483
  • 4.4710
  • 4.2895
  • 5.2834
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13 *

.6972 *

.6490 *

.6887 *

.6115 *

.6372 *

.5719 *

.3299 *

. 3 6013..*.3. 9314.*. 3. 7380..*. 4.3717..*. 4.2642..*. 4 7925.*. 8. 3155.*.

14 *

.6469 *

.5769 *

.5998

  • 5955 *

.5162 *

.3384 *

  • 3. 8890..*. 3. 7124
  • 4 2726
  • 4.4208
  • 5.2450
  • 8.0979
  • e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15 *

.4969 *

.4145 *

.2367 *

.3791

  • 4.9798
  • 5.9922 *10.6186
  • 6.8442
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.....

l

Catawba 2 Cycle 7 Core Operating Limits Report Page 64 of 144 Appendlix A TABLE 1 (CONTINUED)

F-SUB-Q E H-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 50% POWER, 150 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

D A

.... H....... e

  • Q* e....... F......... E. e e e e e e e e e e e e e e e e
  • C....... B ee eeeeeeeeeeee..e l

1 8*

.4048 *

.3748 *

.6672 *

.4734 *

.6737 *

.7636 *

.6265 *

.4552

  • e s e e.137..*.4 1317.*.e e e. 53 3 5
  • 3. 67 2 0
  • 2. 5 6 60
  • 2.142 6
  • 2.3 06 3
  • 2. 977 9
  • 2 3.2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9*

.3748

  • 5430 *

.4338 *

.7058 *

.5023 *

.7401 *

.7186 *

.4327 *

. 4 1317..*.2. 7752..*. 3. 7284.*. 2. 4155

  • 3.3820
  • 2.2667
  • 2.2268.*.3. 4893..*

.eeeeeeeeeeeeeeeeeeeeeeeeeeee..

10 *

.6672 *

.4338 *

.5912 *

.4498 *

.7090 *

.7733 *

.6812 *

.2924 *

  • 2.5335..*.3. 7240.*.2. 4510
  • 3.5769
  • 2. 3809..* 2.e.1617..*. 2. 4411.*.5. 6269.*

eeeee

.eeeeeeeeeeeeeee e

11 *

.4734 *

.7101 *

.4509 *

.6040 *

.4316 *

.6415 *

.6372 *

.4413

  • e.3. 6720..*. 2. 4081.*.3. 5648..*.2. 4794
  • 3.4183
  • 2.3754.*.2. 4889
  • 3.7267 *

. eeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeee.

12 *

.6737 *

.5044 *

.7122 *..4327 *

.5152 *

.5473 *

.5098 *

  • 2. 5660.*.3. 3642..*.2. 3721.*.3. 4107...*.2. 3200
  • 2.3041
  • 2.8337
  • e.

eeeeeeeeeeeeeeeeeeeee.

13 *

.7636 *

.7422 *

.7765 *

.6437 *

.5494 *

.4466 *

.3202

  • e.. 1426..* 2. 2618.*.2. 1557
  • 2. 3699..*.2 2975.*. 2. 5528 *... 4 1136..*
  • 2 14 *

.6265 *

.7197 *

.6833 *

.6394 *

.5119 *

.3256 *

      • eeeeee. 3. 2267..*.2. 43.54...*.2. 4829
  • 2.8210
  • 4.0402 *
  • 2.3063 *.

e***eeeeeeeeeeeeeeeeeee.

15 *

.4552 *

.4338 *

.2935 *'.4423

  • 2. 97 7 9.. *. 3. 4 8 9 3.. *.5.

616 9.*. 3. 718 3..* M-SUB-Q AT 50% POWER, 150 EFPD, THIS IS LEVEL 17 OF 18 (LEV 5L 18 = TOP OF CORE, LEVEL 1 m BOTTOM) i D

A e...H.........Q........F.........E..eeeeeeeene......C.........Beeeeeeeeeeeeee.

8*

.5687

  • 1.0260
  • 1.0560
  • 1.2059
  • 1.0282
  • 1.1267
  • 1.0025 *

.0065 *

  • 2.7922
  • 2.0159
  • 2.0698
  • 1.8584
  • 2.1838'* 1.9607
  • 1.9877
  • 2.3962 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.0260 *

.8804

  • 1.1492
  • 1.0913
  • 1.2049
  • 1.1363
  • 1.0871 *

.6576

  • 2.0159
  • 2.3198
  • 1.8737
  • 2.00...9 6. *.1. 8 013.*. 1. 913 3.*. 1. 9 4 9 6..* e e e. 0 4 0 9
  • 3 eee
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.0560
  • 1.1503 *

.9382

  • 1.1663
  • 1.0956
  • 1.1171
  • 1.0324 *

.8097 *.

  • 2. 0698.*.1 8719..*. 1. 9799..*. 1. 8268..*.1. 9.488.*.1. 9352..*.2. 0.691.*.2 6409..*.

l 11

  • 1.2059
  • 1.0967
  • 1.1717 *

.9082

  • 1.0817 *

.9746 *

.9735 *

.6608 *

  • 1. 8584.*. 2. 0034.*. 1. 8234. 8. 2. 153.4.*.1. 8232..*.2. 0082..*.2. 0857..*.3. 1828
  • eeeeee r

12

  • 1.0282
  • 1.2145
  • 1.1010
  • 1.0849 *

.7165 *

.8268 *

.7722

  • l l

e e e e 83 8

  • 1.7 9 3 8
  • 1. 9 4 01
  • 1. 8181
  • 1. 9 6 8 4
  • 1. 9 69 3
  • 2. 3 6 9 9
  • l
  • 2.1
  • eeeeeee**eeeeeeeeeeeeeeeee..eeeeeneseeeeeeeeeeeeeeeeeeee.

13

  • 1.1267
  • 1.1406
  • 1.1224 *

.9778 *

.8311 *

.6758 *

.4670 *

  • 1. 9 6 07.. *. 1. 9 0 6 7.. *. 1. 9 2 7 6.. *.2.

0 019.. *. 1. 9 6 3 3.. *. 2. 12 57.. *. 3. 5 6 2 9..

  • l 14
  • 1.0025
  • 1.0892
  • 1.0346 *

.9768 *

.7765 *

.4766 *

  • 1. 9877..*. 1. 9467..*.2. 0637..*. 2. 0791
  • 2.3597
  • 3.4954
  • eeeeeeeeeeeeeeeeeeee.

15 *

.8065 *

.6576 *

.8107 *

.6619

  • 2. 3962..*.3 0409..*. 2 6356 *... 3. 1750.* M-SUB-Q e.

i i

1 l

l I

l i

I N

l t

F

Catawha 2 Cycle 7 Core Operating Limits Report Page 65 of 144 Appendix A l

I I

TABLE 1 (CONTINUED) j F-SUB-Q & H-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION

)

i 1

AT 50% POWER, 150 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

H G

C B

A eeeeeeeeeeeeeeeeeeeee.F.........E........D eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7090

  • 1.3345
  • 1.3527 *'1.5305
  • 1.2616
  • 1.4030
  • 1.2959
  • 1.0892
  • 1
  • 2. 5 3 67.. *.1.7 6. 9 6. *. 1. 8 3 4 8.. *.1.

6 5 4 2.. *.1.

9 9 9 7...*.1.

7 9 6 3. *.1.8 9 57.. *.2.2 3 4 4. *.

e.

9

  • 1.3345
  • 1.1395
  • 1.4919
  • 1.3848
  • 1.5197
  • 1.3805
  • 1.3537 *

.8290 *

. 1.7696

  • 2 0806.*. 1. 6470
  • 1.7958.*. 1. 6410...*.1. 78.54
  • 1 82.14.*.2. 9334.*

eeeeeeeeee

.. eeeeeee..

10

  • 1.3527
  • 1.4930
  • 1.3666
  • 1.4919
  • 1.3527
  • 1.3837
  • 1.2413
  • 1.0046
  • l
  • 1.8348
  • 1.6450
  • 1.7606
  • 1.6275
  • 1.7863
  • 1.7641
  • 1.9493
  • 2.4186
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

t l

11

  • 1.5305
  • 1.3902
  • 1.4983
  • 1.1588
  • 1.3698
  • 1.1738
  • 1.1802 *

.7958

  • l

. 1. 6542..*.1. 7918.*.1 6275.*. 1. 9643.*. 1. 6.338..*. 1 8667..*.1 9345

  • 2.9714
  • t

... eeeeeeeeeeeeee.

12

  • 1.2616
  • 1.5305
  • 1.3591
  • 1.3730 *

.8825 *

.9982 *

.9136 *

.eeeeeeeeeeeeeee.299

  • 1 8134
  • 1.8173
  • 2.2417
  • 1.7787
  • 1.6......
  • 1 9997..*.1. 6339 eeeeeeeeeeeeeeeeeeeeeee.

e..

13

  • 1.4030
  • 1.3859
  • 1.3902
  • 1.1781
  • 1.0025 *

.7979 *

.5366

  • e.1. 7963
  • 1. 7785.*. 1. 7566.*. 1. 8608
  • 1.8124
  • 2.0048
  • 3.4492 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2959
  • 1.3559
  • 1.2445
  • 1.1845 *

.9178 *

.5473 *

  • 1. 8957..*. 1. 8190.*.1.9456
  • 1.9282
  • 2.2308
  • 3.3839 *

......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

l 15

  • 1.0892 *

.8290

  • 1.0057 *

.7979

  • 2. 2344.*. 2. 9334.*. 2. 4144.*. 2. 9628.* M-sUB-Q l

(

AT 50% POWER, 150 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G.........F.........E.........D.........C.........B.........A......

8*

.8011

  • 1.5294
  • 1.5369
  • 1.7307
  • 1.4041
  • 1.5733
  • 1.4598
  • 1.2381 *
  • 2.4446
  • 1.6892
  • 1.7617
  • 1.59 1
  • 1.8803
  • 2.2118
  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.13.. *.1.

9 437..

  • e e e.7 48 9 eeeeeeeeeeeeeeeeeeeeeeen l

9

  • 1.5294
  • 1.2981
  • 1.7093
  • 1.5658
  • 1.1179
  • 1.5315
  • 1.5176 *

.9264 *

  • 1. 6892..*. 2. 0008..*. 1. 5740 *.... 1. 7311.*. 1. 5775..*.1. 7554.*. 1. 7890.*.2. 9218.*

e.

10

  • 1.5369
  • 1.7104
  • 1.5722
  • 1.7072
  • 1.5165
  • 1.5487
  • 1.3677
  • 1.1149 *

. 1 7617...*.1. 5723.*.1. 6989.*.1. 5617..*.1. 7339.*. 1 7146..*. 1. 9277..*.2. 3824.*.

11

  • 1.7307
  • 1.5690
  • 1.7093
  • 1.3077
  • 1.5465
  • 1.2938
  • 1.3034 *

.8707 *

  • 1.5913
  • 1 72.83..*. 1. 562.3
  • 1.9080
  • 1. 5781
  • 1 8344.*.1. 9031.*.2. 9504.*

eeeeeeeeeee.

12

  • 1.4041
  • 1.7297
  • 1.5240
  • 1.5508 8

.9610 a 2,o973 e

,9950 *

  • 1.9437
  • 1.5710
  • 1.7261
  • 1.5739
  • 1.7837
  • 1.7835
  • 2.2272 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13 a 1.5733
  • 1.5300
  • 1.5562
  • 1.2981
  • 1.1031 *

.8675 *

.5762 *

  • 1.7489
  • 1.7482
  • 1.7070
  • 1.8287
  • 1.7774
  • 1.9915
  • 3.4534 *-

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.4598
  • 1.5197
  • 1.3720
  • 1.3077 *

.9992 *

.5800 *

  • 1.8803
  • 1.7866
  • 1.9233
  • 1.8962
  • 2.2166
  • 3.3857
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 15

  • 1.2381 *

.9264

  • 1.1171 *

.8729

. 2. 2118.*. 2. 92.39.*. 2. 3784.*.2. 9440.* N-SUB-Q l-1 l

l 1

E

l Catawha 2 Cycle 7 Core Operating Limits Report Page 66 of 144

)

Appendix A j

TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUBS (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 50% POWER, 150 NFPD, THIS IS LEVEL 14 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

D C

B A

e...H.......O.........F.........E.. e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e ee 8 *

.0365

  • 1.5958
  • 1.5926
  • 1.7929
  • 1.4405
  • 1.6226
  • 1.4962
  • 1.2691
  • 2.5968
  • 1.7888
  • 1.8734
  • 1.6862
  • 2.0746
  • 1.5710
  • 2.0314
  • 2.3912
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5958
  • 1.3441
  • 1.7800
  • 1.6183
  • 1.7789.* 1.5679
  • 1.5583 *

.9446 *

    • e.888.*..2. 12.43..*.1 6684.*. 1. 8471
  • 1.6775
  • 1.8894
  • 1.9258
  • 3. 1590..*.
  • 1.7...

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

i 10

  • 1.5926
  • 1.7821
  • 1.6301
  • 1.7779
  • 1.5615
  • 1.5947
  • 1.3944
  • 1.1385
  • 1.8734
  • 1.6664
  • 1.8133
  • 1.6605
  • 1.8558
  • 1.8333
  • 2.0861
  • 2.5797
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-11
  • 1.7929
  • 1.6215
  • 1.7000
  • 1.3484
  • 1.6011
  • 1.3216 8.1.3323 *

.8814

1. 8439.*.1 6605
  • 2.0365.*. 1. 6833..*.1. 9778..*.2. 0.547..*.3. 2076..* -
  • 1.6862 *

..... eeeeeeeeee...

eeeeee.e...

]

12

  • 1.4405
  • 1.7907
  • 1.5690
  • 1.6054
  • 1.0121.* 1.1224
  • 1.0089

. 2. 0746..*.1. 6709.*.1 8471..*. 1. 6787

  • 1.9251
  • 1.9231
  • 2.4189

)

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6226
  • 1.5754
  • 1.6033'* 1.3270
  • 1.1278 *

.5825

  • 5816
  • 1 1.8254
  • 1.9714
  • 1.9162
  • 2.1612
  • 3.7512 *

'

  • 1. 8710..*e e e e. 8 018
  • eeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.4962
  • 1.5604
  • 1.3977
  • 1.3355
  • 1.0142 *

.5933

  • e.2. 0 314..*. 1. 9 2 2 4. *.2.0 810.. *.2.0 47 0.*.2. 4 07 9.. *.3.67 0 6
  • 15
  • 1.2691 *

.9436

  • 1.1406
  • 8836
  • 2. 3 912. * ' 3. 159 0
  • 2. 57 51
  • 3.2 0 03
  • N-8UB-Q ee eeeeeeeeeeeeeeeeeeeeee.

AT. 50% POWER, 150 XFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

.....O.. e e e e e e e e e e e e e e e e.........D.........C......... B......... A......

e...H...

F E

1.6793

  • 1.6697
  • 1.8753
  • 1.5015
  • 1.6933
  • 1.5540
  • 1.3195 *'

8*

.8889 *

1. 8 9 2 4.*.1. 9 8 7 7..*. 1. 7 8 5 6.*e e e e.19 9 8
  • 1. 9 9 2 3.. *.2.

167 0..*. 2. 5 2 2 9.. *.

2

  • 2.7437
  • eeeeee.

eeee**ee...

9

  • 1.6793
  • 1.4094
  • 1.8678
  • 1.6933
  • 1.8614
  • 1.6322
  • 1.6236 *

.9789 *

. 1. 8924.*.2. 2.444.*. 1. 7694.*. 1. 9641

  • 1.7834
  • 2.0204
  • 2.0562
  • 3.3328
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6697
  • 1.0700
  • 1.7050
  • 1.8657
  • 1.6301
  • 1.6665
  • 1.4469
  • 1.1835 *
  • 1. 9877..*. 1. 7672..*. 1. 9298..*. 1. 7665.*. 1. 9795.*. 1 9543..*.2. 2369.*.2. 7644.*.

e.

11

  • 1.8753
  • 1.6954
  • 1.8668
  • 1.4084
  • 1.6772
  • 1.3773
  • 1.3069 *

.9114

  • 47..*. 1. 7968.*.2. 1242.*. 2. 3059.*.3. 4550..*
  • 1.7856
  • 1.9615
  • 1.7665 8 2.16 eeeeeeeeeeesenesseesessesseeeeee.

12

  • 1.5015
  • 1.8742
  • 1.6376
  • 1.6825
  • 1.0689
  • 1.1760
  • 1.0485 *

]

  • 2.19 9 8. *.1. 7 7 6 0.*.1. 9 713..*. 1. 7 915.*. 2. 07 4 0.. *. 2. 0 6 B 0.. *.2.

613 3...* -

e ee...

13

  • 1.6933
  • 1.6397
  • 1.6740
  • 1.3827
  • 1.1802 *

.9286 *

.6062 *

  • 1.9923
  • 2.0119
  • 1.9455
  • 2.1169
  • 2.0611
  • 2.3375
  • 4.0386
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee it
  • 1.5540
  • 1.6250
  • 1.4501
  • 1.3912
  • 1.0539 *

.6180

  • easeeeeeeeeeeeeeeeeeeee.22..*e 2.2002
  • 2.6007
  • 3.9590 *
  • 2.1670
  • 2.0522
  • 2.23 eeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.3195 *

.9778

  • 1.1845
  • 9136

. 2. 5229..*.3 3355.*. 2. 7591.*.3. 4467..*. M-sUB-Q i

h---

i -

-a m

y e-r-~-w m

g.g

+rpy-

Catawha 2 Cycle 7 Core Operating Limits Report Page 67 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 150 EFPD, THIS IS LEVEL 12 OF 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

A s e e e e e e e e e e e e e e e e e e e.. F......... E......,.. D......... C......... B...............

8*

.9018

  • 1.6922
  • 1.6740
  • 1.8817 + 1.4963
  • 1.6954
  • 1.5487
  • 1.3152 *
  • 3. 0541.*. 2. 0.929.*.2. 2059..*. 1. 975.6.*.2. 4.338..*.2. 1848..*. 2. 3571
  • 2.7368
  • eeeeeeeeeeeeee.

9

  • 1.6922
  • 1.4126
  • 1.8764
  • 1.6943
  • 1.8668
  • 1.6290
  • 1.6215 *

.9725

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9792..*eeee.2518
  • 2 2.588 *.... 3. 6289..*

2 2.4983

  • 1.9612
  • 2.1859
  • 1..
  • 2.0929
  • eeeee...

10

  • 1.6740
  • 1.8785
  • 1.7061
  • 1.8742
  • 1.6311
  • 1.6697
  • 1.4416
  • 1.1792 *
  • 2.2059
  • 1.9586
  • 2.1490
  • 1.9612
  • 2.2070
  • 2.1716
  • 2. 4971
  • 3. 0574.*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeee.

11

  • 1.8817
  • 1.6975
  • 1.8753
  • 1.Y105
  • 1.6868
  • 1.3784
  • 1.3869 *

.3061 *

. 1 9756.*. 2. 1826..*.1. 9595

  • 2.4213
  • 2.0020
  • 2.3817
  • 2.4644
  • 3.8648 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 12

  • 1.4983
  • 1.8796
  • 1.6386
  • 1.6911
  • 1.0828
  • 1.1835
  • 1.0496
  • 9711
  • 2.1981
  • 1.9965
  • 2.3318
  • 2.3193
  • 2.9392
  • 1
  • 2.4338
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeee.

13

  • 1.6954
  • 1.6365
  • 1.6772
  • 1.3827
  • 1.1888 *

.9403 *

.6073 *

  • 2.1848
  • 2.2424
  • 2.1619
  • 2.3739
  • 2.3118
  • 2.6257
  • 4.5516
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.5487
  • 1.6236
  • 1.4448
  • 1.3912
  • 1.0549 *

.6201

  • eee**ee...
2. 2553..*.2. 4913
  • 2.4574
  • 2.9253
  • 4.4607 *
  • 2.3571 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.3152 *

.9725

  • 1.1813 *

.9082 *'F-SUB-Q i

  • 2. 7 3 6 0.. *. 3. 6 3 2 0.*.

3 0 5 31.*. 3. 8 5 4 4. *. M-SUB-Q AT 50% POWER, 150 EFPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H O

D C

B A

e e e e e e e e e e e e e e e.......F.........E....e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.

8*

.8943

  • 1.6772
  • 1.6504
  • 1.8582
  • 1.4737
  • 1.6718
  • 1.5219
  • 1.2927
  • eneeeeeeeeeeeeeeeeeeee.813.e*eeee.1716
  • 2.6806
  • 2.3752.e*eeee.5696
  • 2.9735
  • 2 2
  • 3.4981
  • 2.3636
  • 2.4.

eeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeee 9

  • 1.6772
  • 1.3934
  • 1.8560
  • 1.6697
  • 1.8443
  • 1.6022
  • 1.5969 *

.9532

  • 3
  • 2.3636
  • 2.8560
  • 2.2070
  • 2.4408.*. 2.e.1870
  • 2.4785
  • 2.4518.*eeee.9835
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeeeeeeeeeeeeeeee..

eeeeee 10

  • 1.6504
  • 1.8582
  • 1.6815
  • 1.8539
  • 1.6076
  • 1.6493
  • 1.4169
  • 1.1610 *

... 4 813.. *. 2. 2 0. 4 8. *. 2. 4 3 67.. *. 2. 2 0 9 3.. *. 2. 5 07 2.. *. 2. 4 2 3 0.. *. 2. 7 612.. *. 3. 2 9 9 6..

  • 2 11
  • 1. 8 5 82
  • 1. 6718
  • 1. 8 5 50
  • 1. 3 9 23 + 1. 67 0 8
  • 1. 3 602
  • 1. 3 6 9 8 *

.8900 *

                • ee.2. 4367. **2.2070
  • 2.7817.***2 2706
  • 2.7077
  • 3.7969
  • 4. 3108.*
  • 2.1716
  • 6

.e eeeeee

  • e
                    • eeeeeeeeeeee.

12

  • 1.4737
  • 1.8560
  • 1.6151
  • 1.6761
  • 1.0742
  • 1.1760
  • 1.0389 *
  • 2. 680.6.*. 2. 1727..*. 2. 4971..*.2.2647
  • 2.6498
  • 2.6273
  • 3.3326
  • e.

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.6718
  • 1.6097
  • 1.6568
  • 1.3655
  • 1.1813 *

.9371 *

.6030

  • e. 2. 3 7 5 2.. *. 2. 4 6 8 6. *.2.

410 9.. *. 2. 6 9 9 3.. *. 2. 619 3. *.2.

9 817.. *. 5. 2110..

  • 14
  • 1.5219
  • 1.6001
  • 1.4212.* 1.3741
  • i.0442 *

.6148 *

  • 2.5696.*.2. 4.491..*.2.7542.*. 2.7897..*.3 3173.*. 5. 1114..*.-

e.....

. ee...

    • e 15
  • 1.2927 *

.9532

  • 1.1620 *

.8921

  • 3. 2971..*. 4 3023..*. N-SUB-Q

.eeeeee 4

1 e -

Catawba 2 Cycle 7 Core Operating Limits Report Page 68 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OF MARGIN) - NORMAL OPERATION AT 50% POWER, 150 EFPD, THIS IS LRVRL 10-OF 18 (LEVEL 18 m TCP OF CORE, LEVEL 1 a BOTTOM)

H G

F.

E D

C B

A

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8 *

.9061

  • 1.7007
  • 1.6665
  • 1.8796
  • 1.4833
  • 1,6868
  • 1.5315
  • 1.3023
  • l

. 3. 7386..*.2. 5130

  • 2.6146
  • 2.2838.*. 2. 8496.*.2. 4927..*.2. 6893..*.3. 0946..*

eeeeeeeeeeeeeeeeee..

.e..

9

  • 1.7007
  • 1.4084
  • 1.8785
  • 1.6847
  • 1.8625
  • 1.6161
  • 1.6119 *

.9585 *

  • 2.5130
  • 3.0707
  • 2.3193
  • 2.5727..*.'2. 2984
  • 2.6052
  • 2.5651
  • 4.1968
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

... eeeeeeeeeeeeeeeeeeeeeeeeee.-

10

  • 1.6665
  • 1.8807
  • 1.6965 *.1.0753
  • 1.6236
  • 1.6686
  • 1.4309-* 1.1717
  • 2.6146
  • 2.3100
  • 2.5712
  • 2.3230
  • 2.6498
  • 2.5410
  • 2.8921
  • 3.4384
  • eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.8796
  • 1.6868
  • 1.8775
  • 1.4094
  • 1.6986
  • 1.3805
  • 1.3923 *

.8996 *

  • 2.2838
  • 2.5681
  • 2.3205
  • 3.0086
  • 2.4435
  • 2.9552
  • 3.0065
  • 4 5035
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.4833
  • 1.8742
  • 1.6311
  • 1.7040
  • 1.0935
  • 1.2049
  • 1.0614
  • e.2. 8496..*.2. 2838..*.2. 638.5
  • 2.4367
  • 2.8941
  • 2.8883
  • 3.6840
  • eeeeeeeeeeeeeeeeeeeeeee...eeeeeeeeeeen 13
  • 1.6868
  • 1.6226
  • 1.6772
  • 1.3859
  • 1.2102 *

.9660 *

.6201 *

  • 2. 4 9 27..*.2. 5 9 5 8.*.2. 5 3 0 6.*.2.9 4 5 2.*. e e e. 87 87.
  • 3. 2 9 4 6.*.

5 8. 5 3 9..*.

2 e.

. ee.

eee..

14

  • 1.5315
  • 1.6151
  • 1.4341
  • 1.3955
  • 1.0667 *

.6319 *

. 2. 6 8 9 3. *. 2. 5 6 2 0. *.2.8. 8 6 3..*.2.

9 9 82.. *.3.6. 6 0 4. *. 5. 7 3 7 2.. *..

j 15

  • 1.3023 *

.9585

  • 1.1738 *

.9018

. 3. 0 9 4 6. *. 4. 19 6 8.. *. 3. 4 3 3 0.. *. 4. 4 9 42.. *e N-SUB-Q e#e.

AT 50% POWER, 150 RFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.9061

  • 1.6793
  • 1.6301
  • 1.8432
  • 1.4437
  • 1.6483
  • 1.4919
  • 1.2691
  • e.3. 9031.*.2. 5306.*.2. 5757..*. 2. 2623..*.eee.8521
  • 2.4985
  • 2.7386
  • 3.1903
  • 2 eeeeeeeeeeeeeeseeeeeeeeeeeeeeeeee j

9

  • 1.6793.* 1.380'S
  • 1.8443
  • 1.6440
  • 1.8218
  • 1.5787
  • 1.5754 *

.9318 *

  • 2.5306
  • 3.0510
  • 2.2814
  • 2.5425
  • 2.2790
  • 2.6337
  • 2.6130
  • 4.3498
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6301
  • 1.8453
  • 1.6590
  • 1.8410
  • 1.5904
  • 1.6386
  • 1.4009
  • 1.1449 *

... 5757..*. 2. 2790..*.2. 5395..*. 2. 2886.*. 2. 6498.*eee.5575

  • 2.9735
  • 3. 5805.*e 2

... e eeeeeeeeeeeeeee.

11

  • 1.8432
  • 3.6461
  • 1.8432
  • 1.3880
  • 1.6868
  • 1.3698
  • 1.3762'*

.8814 *

]

4 6 61..*. 2. 62 91 *. 3. 07 0. e e *.3. e. 0 9 9 0...*.4.

7 5 0. 4.*

  • 2.2623
  • 2.5395
  • 2.2874
  • 3.0 i

j eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

seeeeeeeeeees e.

12

  • 1.4437
  • 1.8346
  • 1.5279
  • 1.6922
  • 1.1063
  • 1,2220
  • 1.0635
  • j
  • 2. 8.521.*. 2.2647..*. 2. 6369..*. 2. 5218...*.3. 0086 *.... 2. 9920..*. 3. 8238.*

i

    • e..

13

  • 1.6483
  • 1.5851
  • 1.6461
  • 1.3752
  • 1.2274 *

.9960 *

.6276

  • l
  • 2.4985
  • 2.6209
  • 2.5455
  • 3.0596
  • 2.9837
  • 3.4167
  • 6.1365
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.4919
  • 1.5776
  • 1.4041
  • 1.3805
  • 1.0689 *

.6405

  • j
  • 2.7386
  • 2.6083
  • 2.9674
  • 3.0902
  • 3.8070
  • 6.0172
  • j

.j eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*e eeeeeeeee.

15

  • 1.2691 *

.9318

  • 1.1470 *

.8836

  • 3.1903
  • 4.3498
  • 3.5746
  • e,7400
  • N-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

Catawba 2 Cycle 7 Core Operating Limits Report Page 69 of 144 j

Appendix A i

TABLE 1 (CONTINUED) 1 F-SUB-Q & M-SUB-Q VALUES (F-DUB-Q OP MARGIN) - NORMAL CPERATION AT 50% POWER, 150 EFPD, THIS Z8 LEVEL 8 Of 18 (LEVEL 18 m TOP OF CORE. LEVEL 1 = BOTTOM)

....H.........G.........F.........H.........D.........C........B........A......

  • 1.4651
  • 1.6761
  • 1.5144
  • 1.2906
  • 8* 1.0121
  • 1.7393
  • 1.6643
  • 1.8828

. 3. 8 3 7 4..*.2.3 8 57.. *. 2.,. 4 3 3 9

  • 2.13 8 4.*. 2. 7 0 2 7.. *.2.

3 62 3.. *.2.57 7 3.. *.2.9 7 3 5.*e eeeeeeeeee.

9

  • 1.7393
  • 1.4180
  • 1.8860
  • 1.6761
  • 1.8582
  • 1.6097
  • 1.6065 *

.9457

  • 2.3857
  • 2.8844
  • 2.1533
  • 2.4055
  • 2.1543
  • 2.4899
  • 2.4616
  • 4.0604
  • seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6643
  • 1.8882
  • 1.6933
  • 1.8839
  • 1.6311
  • 1.6804
  • 1.4341
  • 1.1695
  • e.2. 4 3 3 9..*.2.15 2 2
  • 2. 4 0 2 9. *.2.

16 0 8. *. 2 5 0 57.. *.2.

413 6...*.2.8 0 9 6.*.3. 3 4 2 9. *.

11

  • 1.8828
  • 1.6783
  • 1.8850
  • 1.4341
  • 1.7607
  • 1.4341
  • 1.4276 *

.9050 *

  • 2 13 8. 4.*.2. 402 9.*.2. e.15 97
  • 2. 8 97 9.*.2.40 9 6
  • 2. 9 8 58
  • 2. 919 4
  • 4. 4572
  • e..

eeeeeeeeee...

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12

  • 1.4651
  • 1.8678
  • 1.6386
  • 1.7661
  • 1.2531
  • 1.3452
  • 1.1310
  • ee. 7027. *eeee.1405
  • 2. 4942
  • 2.4015..*.2. 9941.*.2. 9532..*. 3. 7124.*e
  • 2 2

eeeeee.

.eeeeeeeee..

13

  • 1.6761
  • 1.6172 + 1.6879
  • 1.4394
  • 1.3505
  • 1.1470 *

.6801 *

  • 2.3623
  • 2.4785
  • 2.4029
  • 2.9735
  • 2.9452
  • 3.3820
  • 5.9757
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.5144 + 1.6086
  • 1.4373
  • 1.4319
  • 1.1363 *

.6940 *

  • 2.5773
  • 2.4588
  • 2.8023
  • 2.9116
  • 3.6966'* 5.8625
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2906 *

.9457

  • 1.1706 *

.9071

  • 3.3377
  • 4.4480
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeees.

AT 50% POWER, 150 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H B

A e e e e

  • e....... G........ F.........E......... D.........C.. e e e e e e e e e e e e e e e e e e e e e.

8

  • 1.1245
  • 1.7586
  • 1.6600
  • 1.8796
  • 1.4523
  • 1.6665
  • 1.5037
  • 1.2820
  • e.3. 6560.*.2. 2343
  • 2.2862
  • 1.9965
  • 2.5247
  • 2.1947
  • 2.3870
  • 2.7490
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.7586
  • 1.4212
  • 1.8850
  • 1.6675
  • 1.8593
  • 1.6054
  • 1.6011 *

.9371 *

  • 2. 2343..*.2. 7094.*. 2. 0179... 2 2576..*.2. 0113.*.2. 3100.*.2. 2754.*.3. 7673.*

10

  • 1.6600
  • 1.8871
  • 1.6890
  • 1.8828
  • 1.6343
  • 1.6836
  • 1.4341
  • 1.1663 *
  • 2.3456
  • 2.2459
  • 2.5989
  • 3.0902 *

. 2.2862

  • 2.0160
  • 2.2588
  • 3.0254

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.8796
  • 1.6697
  • 1.8850
  • 1.4469
  • 1.7982
  • 1.4683
  • 1.4480 *

.9082 *

  • 1.9965
  • 2.2541
  • 2.0245
  • 2.7179
  • 2.2518
  • 2.7825
  • 2.6993
  • 4.1222
  • j seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

12

  • 1.4523
  • 1.s60s
  • 1.6408
  • 1.8036
  • 1.4459
  • 1.4725
  • 1.1738 *

. 2. 5247..*. 1. 9983..*. 2 3355.*. 2. 2459...*.2. 8391..*.2. 7861.*.3. 5109.*.

13

  • 1.6665
  • 1.6119
  • 1.6911
  • 1.4737
  • 1.4758
  • 1.2734 *

.7176

  • 2
  • 2.7772
  • 3.1832
  • 5.6485
  • e.2.19. 47.. *. 2. 3 0 81.*.2.

2 3 67. e *e e e e.7 718 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 14

  • 1.5037
  • 1.6033
  • 1.4373
  • 1.4523
  • 1.1002 *

.7315 *

  • 2.3870
  • 2.2718
  • 2.5927
  • 2.6926
  • 3.4939
  • 5.5401
  • e eeeeeeeeeeeeeeeeeeeeeeeee sseeeeeeeeeeeeeeeeeeeeeeeen 15
  • 1.2820 *

.9382

  • 1.1674 *

.9104

  • F-SUB-Q e. 2. 7 4 9 0. *. 3 7 6 7 3.. *. 3. 0 8 8 0.. *. 4. 110 4. *e M-SUB-Q l

w

i a

d Catawba 2 Cycle 7 Core Operating Limits Report Page 70of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION 1

AT 50% POWER, 150'BFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F B

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.4052

  • 1.6194
  • 1.4598
  • 1.2466
  • 8
  • 1.1203
  • 1.7232
  • 1.6119
  • 1.8303 e.3. 4604
  • 2.1269
  • 2.1837
  • 1.9017
  • 2. 4163
  • 2.0919
  • 2.2754
  • 2.6178.*

4

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.7232
  • 1.3827
  • 1.8378
  • 1.6183
  • 1.8153
  • 1.5637 *-1.5594 *-.9093
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.2
  • 2.1630
  • 3. 5983 *
  • 2.1269
  • 2.5896
  • 1.9221
  • 2.1576
  • 1.9170
  • 2.208 eeeeeeeeeeee.

...e.

I 10

  • 1.6119
  • 1.8400
  • 1.6418
  • 1.8368
  • 1.5947
  • 1.6451'* 1.3998
  • 1.1385 *.

e.2. 1837...*.1.9212

  • 2.1565
  • 1.9281
  • 2.2332
  • 2.1331
  • 2.4700
  • 2.9392.*

1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.8303
  • 1.6204
  • 1.8378
  • 1.4180
  • 1.7779
  • 1.4566
  • 1.4287 *

.8889 *

  • 1.9027
  • 2.1543
  • 1.9264
  • 2. 5850
  • 2.1289
  • 2.6289.*eee.5485
  • 3.9136
  • 2
    • eeeeeeeeeeeeeeeeeeeeeeeee..

. eeeeeeeeeeeeeeeee.. e eeeeeeeeeeeeeen 12

  • 1.4052
  • 1.8228
  • 1.6022
  • 1.7832
  • 1.4716
  • 1.4973
  • 1.1749
  • 2.4163
  • 1.9043
  • 2.2229
  • 2.1227
  • 2.6727.* 2.6225
  • 3.3097
  • eeeeeeeeeeeeee.......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6194
  • 1.5701
  • 1.6526
  • 1.4619
  • 1.5015
  • 1.3055 *. 7229
  • 2.0919
  • 2.1992.* 2.1237
  • 2.6193
  • 2.6162
  • 3.0024
  • 5.3619
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee la
  • 1.4590
  • 1.5615^* 1.4030
  • 1.4330
  • 1.1802 *-.7379 *
  • 2. 2754..*. 2. 1608.*. 2. 4644..*.2. 5410..*.3. 2946..*.5 2578.*

e.

e 15

  • 1.2466 *

.9093

  • 1.1406 *

.8911

  • F-SUB-Q eeeeeeeeeeeeeee.3.*eee.9372
  • 3.9031
  • M-SUB-Q
  • 2.6178
  • 3.595.2 eeeeeeeeesmenee AT 50% POWER, 150 EFPD, THIS IS LEVEL 5 OF 18 :

4 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H 0

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1149
  • 1.7115
  • 1.5990
  • 1.8164
  • 1.3934
  • 1.6097
  • 1.4555
  • 1.2466
  • e.3. 1.554.*.1. 9873..*.2. 047.4.*. 1. 7836
  • 2.2683
  • 1.9586
  • 2.1248
  • 2.4394 *

.eeeeeeeeeeeeeeeeeeeeeeeeeee.**eeeeeeeeee 9

  • 1.7115
  • 1.3720
  • 1.8271
  • 1.6065
  • 1.8078
  • 1.5583
  • 1.5572 *

.9071 *

  • 1.9873
  • 2.4244
  • 1.8007
  • 2.0235.*.1. 7969..*.2. 0591.*. 2. 0151.*.3.e.3584
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeee 10
  • 1.5990
  • 1.8282
  • 1.6301
  • 1.8250
  • 1.5894
  • 1.6429
  • 1.4009
  • 1.1406
  • eeeeeeeeeeeeeeeeeeeee 0198..*.1. 8037
  • 2.0829
  • 1.9864
  • 2.2947
  • 2.7368.*
  • 2.0474
  • 1.7992
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

11

  • 1.8164
  • 1.6076
  • 1.8271
  • 1.4148
  • 1.7811
  • 1.4662
  • 1.4373 *.8921 *
  • 1.7836
  • 2.0207
  • 1. 8022
  • 2.4029.*. 1. 9702..*. 2. 4136..*.2. 3.495..*.3.6285
  • eeeeeeeeeeeeeeeeeeee

.eeeeeeeee..

eeeeeeen 12 a 1.3934

  • 1.8153
  • 1.5969
  • 1.)see
  • 1.4e98
  • 1.6197
  • 1.1910 *
  • 2.2683
  • 1.7851
  • 2.0729
  • 1.9639
  • 2.4230
  • 2.3713
  • 2.9755
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6097
  • 1.5647
  • 1.6504
  • 1.4716
  • 1.5251'* 1.3334 *

.7347 *

. l

. 1. 9 5 8 6.* e e e. 0 513.*e e. e.977 4.* e. 405 5.*.2.

3 6 48

  • 2.7162. e *e e.8 4 61'
  • 4 2

2 1

..eeeeee ee eeeeee.

eeee

..e 14

  • 1.4555
  • 1.5594
  • 1.4041
  • 1.4416
  • 1.1963 *

.7508

  • e.2. 1248
  • 2 0132.e*eeee.2898 *e.... 2. 3 431.*.2.

9 613. *. 4.7 5 0 4. *.

2 ee 15

  • 1.2466 *

.9071

  • 1.1417 *

.8943

  • 2. 4394
  • 3.3584.*. 2. 7334..*.eee.6194..* M-sUB-Q 3

e.

...e ee...

e 1

. -. ~ _

Catawha 2 Cycle 7 Core Operating Limits Report Page 71 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M.SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 50% POWER, 150 EFPD, THIS 18 LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

G F

E D

C B

A e e n.H.......e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e 8

  • 1.0346
  • 1.5958
  • 1.4887
  • 1.6965
  • 1.3023
  • 1.5123
  • 1.3741
  • 1.1792
  • 2

. 3. 15 31. *.1. 9 7 2 9. *. 2. 0 5 42.. *. 1. 7 8 51.. *. 2. 2 7. 5 4. *.1.

9 5 51.. *. 2. 113 4..

  • e e e. 4 2 4 4 *

.ee.

eeeeen 9

  • 1.5958
  • 1.2766
  • 1.7082
  • 1.4983
  • 1.6954
  • 1.4662
  • 1.4705 *

.8557 *

  • 1.9729
  • 2.4217
  • 1.7984
  • 2.0302
  • 1.7984
  • 2.0474..*.2. 0011
  • 3.3455
  • ee***eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

.eeeeeeeeeeee.

10

  • 1.4887
  • 1.7093
  • 1.5208
  • 1.7072
  • 1.4887
  • 1.5455
  • 1.3216
  • 1.0774
  • e.2. 0 5 4 2.. *. 1. 7 9 6 9. *.2.

02 07..*. 1. 8 0 07...*.2.

0719.. *. 1. 9 6 9 3.. *. 2. 2718. *.2.

719 6.

  • 11
  • 1.6965
  • 1.5005
  • 1.7082
  • 1.3259
  • 1.6772
  • 1.3827
  • 1.3602 *

.8418 *

. 1 7851..*.2. 0273..*. 1. 7992..*. 2. 3752.*. 1. 9161.*.2. 3343..*.2. 2996.*.3. 5864.*.

12

  • 1.3023
  • 1.7029
  • 1.4951
  • 1.6825
  • 1.4084
  • 1.4437
  • 1.1310 *
  • 2. 275.4.*.1. 7858.*.2. 0621.*.1. 9102..*.2. 3546.*. 2. 2971.*. 2. 8921.*.

e.

13

  • 1.5123
  • 1.4716
  • 1.5530
  • 1.3800
  • 1.4491
  • 1.2713 *. 6983 *
  • -1.9551;* 2 0388.*.1 9604
  • 2.3255..*.2. 2886.*.2. 6083.*.4 70.40.*.

eeeeeeeeeeee

. eeeeee..

14

  • 1.3741
  • 1.4726
  • 1.3248
  • 1.3645
  • 1.1374 *

.7133

  • e.2. 1134
  • 1 9983..*.2. 2659.*. 2. 2935.*. 2. 8787..*.4 6089.*

15

  • 1.1792 *

.8568

  • 1.0796 *

.8439

  • 2. 4 2 4 4. *. 3. 3 4 5 5..*.2.

716 2.. *. 3. 57 7 5.. *. W -SUB-Q AT 50% POWER, 150 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF COPE, LEVEL 1 = BOTTON)

....H.........O........F.........E.........D.........C.........B.........A......

8*

.9500

  • 1.4608
  • 1.3666
  • 1.5572
  • 1.2124
  • 1.4105
  • 1.2981
  • 1.1128 *

. 3. 1101.*.2. 0011..*.2. 1041..*. 1. 8272

  • 2.3131
  • 1.9846
  • 2.1216
  • 2.4400 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 9

  • 1.4608
  • 1.1770
  • 1.5701
  • 1.3805
  • 1.5669
  • 1.3741
  • 1.3816 *

.8118 *

  • 2. 0011..*. 2. 4560..*.1. 8436..*. 2. 0799... 1. 0 412.. *.2.

0 611.. *. 2. 015.1. *. 3. 3 5 0 7..

  • e.

10

  • 1.3666
  • 1.5712
  • 1.4009
  • 1.5744
  • 1.3805
  • 1.4405
  • 1,2434
  • 1.0100 *

. 2. 10.41.*.1. 8412..*.2. 0650..*. 1. 8.436.*.2. 0960

  • 1.9882
  • 2.2742
  • 2.7472 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.5572
  • 1.3827
  • 1.5744
  • 1.2316
  • 1.5551
  • 1.2948
  • 1.2756 *

.7893 *

  • 1.8272
  • 2.0759
  • 3 eeeeeeeeeeeeeeeee.. 1. 8358
  • 2.3804.*. 1. 9161.*. 2. 3032.*,2. 2.850.e*eee.5953 *

..eeeeee...

e eeeese 12

  • 1.2124
  • 1.5733
  • 1.3869
  • 1.6604
  • 1.31s4
  • 1.3548
  • 1.0678 *
  • 2. 3131..*. 1. 8280.*.2. 0859..*. 1. 9102..*. 2. 313.1.*. 2. 2541..*. 2. 8060.*.

13

  • 1.4105
  • 1.3794
  • 1.4480
  • 1.3002
  • 1.3591
  • 1.2027 *

.6619

  • e n e e e e e e e e e e e e e e e e e e e e e e e e e e e ee e e e e e e e e e e e e e e e e e e e e e e e e e. 57 49..*.

1.9846

  • 2.0523
  • 1.9792
  • 2.2947
  • 2.2471
  • 2.5545
  • 4..

14

  • 1.2981
  • 1.3837
  • 1.2466
  • 1.2798
  • 1.0742 *

.6769 *

  • 2. 1216..*.2. 0123.*. 2. 2695..*. 2. 2790..*eee.7933
  • 4.4802
  • 2 e

eeeeeeeeeeeeeee 15

  • 1.1128 *

.8118

  • 1.0110 *

.7915

  • 2 4408.*. 3. 3507..*. 2 7.438

.eeeeeee.64.*. M-SUB-Q e..

w

1 1

Catawba 2 Cycle 7 Core Operating Limits Report Page 72 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M SUB-Q VALUES (F-8UB-Q OP NARGIN) - NORMAL OPERATION AT 50% POWER, 150 EFPD.

THIS IS LEVEL 2 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM) e e e e e e e e e e e e e e e e e e e e e e......... E......... D......... C......... B........ A......

H G

F 8*

.7840

  • 1.1674
  • 1.1053
  • 1.2595
  • 1.0153 ' 1.1770
  • 1.1256 *

.9393

  • e.3. 5395.*eee.3623
  • 2.4799
  • 2.1533
  • 2.6449
  • 2.2659
  • 2.3495
  • 2.7843
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.1674
  • 9660
  • 1.2574
  • 1.1203
  • 1.2873
  • 1.1663
  • 1.1770 *

.7101 *

  • 2.3623
  • 2.8391
  • 2.1925
  • 2.4463
  • 2.1185
  • 2.3100
  • 2.2671
  • 3.6840
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.1053
  • 1.2584
  • 1.1342
  • 1.2691
  • 1.1449
  • 1.1984
  • 1.0635 *

.8354 *

  • e 4799.e*e.2. 1903.*. 2. 4326.*. 2. 1662
  • 2.3976
  • 2 2826.*eeee.5395
  • 3.1716
  • 2

' 2 eeeeeeeeeeeeeeee..

eeeeeeeeeeeeee.

11

  • 1.2595
  • 1.1235
  • 1.2745
  • 1.0271
  • 1.2649
  • 1.0913'* 1.0710 *

.6640 *

- l l

e.2. 15 3 3.. *. 2 4 3 8 0.*.

2. 157 6.*. 2. 7 0 9 4
  • 2. 2127
  • 2. 5 6 6 6
  • 2. 5 0 0 3
  • 4. 0 0 3 3
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.0153
  • 1.2927
  • 1.1503
  • 1.2691
  • 1.0967
  • 1.1395 8'

9104 *'

' l

  • 2.6449
  • 2.1092
  • 2.3844
  • seeeeeeeeeeeeeeeeeeeeeeeee.. 2.e.2059
  • 2.6052
  • 2.5101
  • 3.1101
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.1770
  • 1.1717
  • 1.2027
  • 1.0956 *'1.1438
  • 1.0207 *. 5751 *
  • 2.2659
  • 2.3094
  • 2.2730
  • 2.5575'* 2.4999
  • 2.8070
  • 4.9400
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.1256
  • 1.1781
  • 1.0667
  • 1.0753 *. 9157 * -.5850 *.

e.2. 3 4 9 5.*.2.2 647..*.2. 53 5 0.*.2. 5727 e *e e e e.09 46

  • 4. 8 3 53
  • 3 eeeeeeeeeeeeeee 15 *

.9393 *

.7101

  • 8365
  • 6651
  • 2. 7 8 4 3. *. 3. 6 8 71.. *. 3. 16 9 3.. *. 4 07 5 6.. *. M-SUB-Q AT 50% POWER, 150 BFPD, TEIS IS LEVEL 1 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

H Q

F 3

D C-B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8 *

.4959 *

.4134

  • 6587 *

.4659 *

.6372 *

.7968 *

.7240 *

.5612 *

. 5. 2 8 9 9

  • 6. 315 4
  • 3. 97 8 3
  • 5. 5 5 4 4. *. 4. 0 4 52. e
  • e e e. 23 07
  • 3. 5 4 5 3
  • 4. 5271 * '

3 eeeeee

.eeeeeeeeeeeeeeeee...

e eeeeeeeeeeeeeeeeeeeeeeee i

9*

.4134 *

.5944

  • 4616 *

.6769 *

.5023 *'.7336 *

.7636 *

.4627 *

  • 6. 315.4.*. 4. 4118..*. 5. 6707..*. 3. 8786.*.5. 1576
  • 3.5366
  • 3.3715
  • 5.5049
  • e.

eeeeeeeeeeee3eeeeeeeeeeeeeeeeeeen 10 *

.6587 *

.4616

  • 6651 *.4766 *

.6908 *

.7872 *

.6704 *'.2892 *

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.980.*.3. 8037
  • 3.3429
  • 3.0960
  • 8.8416.*

3.9783

  • 5.6633
  • 3.9565
  • 5.4...

..eeeeeeeeeeeeeeeeeeeeeeeeeeee 11 *

.4659 *

.6790

  • 4787 *

.6480 *

.4884 *

.6747 *

.6640 * -.4188 *

  • 5.5544
  • 3.8648
  • 5.4840
  • 4.1026
  • 5.4564'* 3.9783
  • 4.0152
  • 6.2426
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeen 12 *

.6372 *

.5055 *

.6940 *

.4894 *

.5704 *

.7019 *

.5633

  • 5'
  • 4.0452
  • 5.1271
  • 3.7871
  • 5.4427
  • 4.0301
  • 3.8786
  • 4.8191
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13 *

.7968 *

.7347 *

.7904 * -.6769 *

.7101 *

.6255 *

.3604 *

..... 4 0 2 8.. *.7.4 312.. *.

. 3. 2307..*. 3. 5309..*.3 3300.*.3. 9638.*.3. 0648 4

14 *

.7240 *

.7636 *

.6726 *'.6662 *

.5666 *

.3759

  • i
  • 3.5453
  • 3.3715
  • 3.8890
  • 4.0004
  • 4.7925
  • 7.2813
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.5612 *

.4627 *

.2892 *

.4198

  • F-SUS-Q e.4 5271..*.5. 5049..*.8. 8236
  • 6.2247
  • M-SUB-Q

..eeeeeeeeeee.

p-~

4 v-

-e

-,v-4,-

w m,

w e.

i 1

Catawba 2 Cycle 7 Core Operating Limits Report Page 73 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 415 EFPD.

THIS IS LEVEL 18 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1.m BOTTOM)

H O

F E

D C.

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8*

.5666 *

.5730 *

.5675 *

.6972 *

.8889 *

.9714 *

.7283 *

.5307

  • e.2. 2330
  • 2. 6913..*.1 8011.*.2. 3000.*. 1. 8162..*.1. 5735.*. 1. 6943.*.2. 1065.'*

9*

.5730 *

.7229 *

.6276 *

.9168 *

.7154 *

.9618 *

.8932 *

.5473 *

  • 2.6913
  • 1.9774
  • 2.3653
  • 1.7614
  • 2.2663
  • 1.6752-* 1.6511
  • 2.5060
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10 *

.8675 *

.6276 * -.7208 *

.6480 *

.9382

  • 1.0132 *

.8814 *. 4305 *

. 1. 8011.*.2. 3.640..*. 1. 7800.*.2. 3706

  • 1.7864
  • 1.6574
  • 1.8692
  • 3.6919.*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11 *

.6972 *

.9200 *

.5490 *

.7883 *

.6426 *

.8782 *

.8750 *

.6040

  • e.2. 3 0 8 0. *.1.7. 5 67.. *. 2. 3 6 8 8. *. 1. 9 6 0 9. *. 2. 57 9 0. *.1. 918 3
  • 1. 9102
  • 2 7 4 6 4.
  • ee. eeeeeeeeeeeeeeeee.

12 *

.8889 *.7176 *

.9403 *

.6437 *

.7026 *

.7840 *

.7229 *

  • 1. 8162..*. 2. 2.550.*.1 7827..*.2. 5769
  • 1.0039
  • 1.8941
  • 2.2934
  • e.

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13 *

.9714 *

.9639

  • 1.0153 *

.8793 *

.7861 * '.6662 *

.4937

  • e.1. 57 3 5.. *.1.6711.. *. 1. 6. 5 4 0. *.1.

916 0. *.1.0 919. *.2.1073...*. 3. 2 6 01.

  • 14 *

.7283 *

.8943 *

.8825 *..5761'*

.7251 *.5002 *

  • 1.6943
  • 1.6511
  • 1.0681
  • 1.9079
  • 2.2867
  • 3.2233
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.5367 *

.5472 *

.4316 *

.6040

  • 2.10 6 5
  • 2. 50 66
  • 3. 6 889.
  • 2.7 4 41
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee AT 50% POWER, 415 EFPD, THIS AS LEVEL 17 OF 18 (LEVEL 18 m TOP OF CORE, LE%dL 1 m BOTTOM)

H 0

F E

D C.

.B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-8*

.7219

  • 1.2424
  • 1.2466
  • 1.4437
  • 1.2242
  • 1.3077 *

.9585 * -,7486 *

  • 2.1018
  • 1.5752
  • 1.5986
  • 1.4299
  • 1.6868
  • 1.5146
  • 1.6245
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.1. 9178..*

9

  • 1.2424
  • 1.0142
  • 1.3548
  • 1.2906
  • 1.4373
  • 1.2991
  • 1.2124 *

.7058 *

  • 1.5752
  • 1.8020
  • 1.4592
  • 1.5791
  • 1.4370
  • 1.5003
  • 1.5952
  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e eee e e e e e e e ee e e e e e e e ee e e e e e ee e e e e.2. 43 0.5.*

10

  • 1.2466
  • 1.3559 *

.9628

  • 1.3709
  • 1.2916
  • 1.3323
  • 1.1802 *.9553 *
  • 1.5986
  • 1 4587
  • 1. 5763
  • 1.4667
  • 1.6350'* 1.5976 *'1.7601
  • 2.0965
  • esee.............

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.4437
  • 1.294.
  • 1.3741
  • 1.0603
  • 1.3163.* 1.1792
  • 1.1877 *

.8065

  • 2 e.1. 4 2 9 9. *.1.57 6 4. *.1 4 6 61..*. 1 8 3 61. *.1.5 9. 4 4. *.1.818 6.. *. 1. 7 9 8 3.
  • e e e. 62 2 9 ' *

... e eeeeee 12

  • 1.2242
  • 1.4437
  • 1.2948
  • 1.3184 *

.8804

  • 1.0442 *

.9650

  • e 1.6868
  • 1.4313
  • 1.6310
  • 1.5931
  • 1.7726
  • 1.7742
  • 2.1801
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.3077
  • 1.3023
  • 1.3345
  • 1.1813
  • 1.0464 *

.8804 *

.6426 *

'* 1. 5146..*. 1. 5760..*. 1. 5945.*. 1. 8152

  • 1.7718
  • 1.9794
  • 3.1273..*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeee 14 *

.9585

  • 1.2134
  • 1.1813
  • 1.1988 *

.9671 *

.6490 *

  • 1.6245.*. 1. 5952...1. 7673..*. 1. 7966
  • 2.1739
  • 3.0922
  • esee

..eeeeeeeeeeeeeeeeeeen 15 *.7486 *

.7058 *

.9553 *

.0075

  • 1.9178
  • 2.4395
  • 2 2

e e e e e e e e e e e e e e e e e e e e. 0 9 65.e

  • e e e. 62.11..*. M-8DB-Q

.. e e

l. -

i.

t Catawba 2 Cycle 7 Core Operating Limits Report Page 74 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q 8 M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 415 BFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

D C

B A

eeeeeeeeeeeeeees......F.........E.......

eee. eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.8300

  • 1.4469
  • 1.4405 8'1.6654 a 1.3709
  • 1.4844
  • 1.0678 *

.8557

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.149.e*eeee.6729
  • 1.9432 *
  • 2.0854
  • 1.5330
  • 1.5630
  • 1.3899
  • 1.6867
  • 1.5.

1 eeeeeeeeeeeeee.

9

  • 1.4469
  • 1.1620
  • 1.5797
  • 1.4801
  • 1.6504
  • 1.4437
  • 1.3516 *

.7733 *

  • 1. 5330..*eeee.7765
  • 1.4168
  • 1.5463
  • 1.4082'* 1.6000
  • 1.6135
  • 2.5329
  • 1 e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.4405
  • 1.5797
  • 1.1245
  • 1.5776
  • 1.4437
  • 1.5015.* 1.2938
  • 1.0710
  • 1.5630
  • 1.4163
  • 1.5444
  • 1.4258
  • 1.6199
  • 1.5849
  • 1.8090
  • 2.1069
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

11

  • 1.6654
  • 1.4844
  • 1.5808
  • 1.1910
  • 1.4705 + 1.2916
  • 1.3109 *

.8868

  • I
  • e e e e e e e e e e e e. e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e. 1. 8 0
  • 1.3899
  • 1.5454
  • 1.4253
  • 1.8269
  • 1.5646
  • 1.8448
  • l eeeeeeeeeeeeee.

12

  • 1.3709
  • 1.6579
  • 1.4469
  • 1.4716 *'.9864
  • 1.1385
  • 1.0389
  • 1.6867
  • 1.4027
  • 1.6163
  • 1.5634
  • 1.7880
  • 1.7926
  • 2.2429
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.4844
  • 1.4469
  • 1.5037
  • 1.2938
  • 1.1406 *

.9382 *

.6737

  • e.1 5.149.*.1.5957
  • 1.5819
  • 1.8415
  • 1.7903
  • 2 0332
  • 3.2590 *

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeee 14

  • 1.0678
  • 1.3537
  • 1.2948
  • 1.3130
  • 1.0410 *

.6812 *'

  • 1.6729
  • 1.6135
  • 1.8082
  • 1.8060
  • 2.2368
  • 3.2256
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.8557 *

.7743

  • 1.0721 *

.8868

  • F-sUB-Q-

. 1. 9432..*.2. 5345.*.2. 1069.*. 2. 6519.*e M-SUB-Q l

.eee l

l AT 50% POWER, 415 EFPD, THIS IS LEVEL 15 OF 18 I

(LEVEL 18 e TOP OF CORE, LEVEL 1 a BOTTOM) l H

G F

E D

C

.B A

[

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8825

  • 1.5508
  • 1.5294
  • 1.7725
  • 1.4266
  • 1.5690
  • 1.1813 *

.9746 *

.. 2. 1580.*.1 5900.*eee.6268

  • 1.4290
  • 1.7587
  • 1.5007
  • 1.7752
  • 2.0521
  • 1

....... e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5508
  • 1.2445
  • 1.6890
  • 1.5583
  • 1.7372
  • 1.5005
  • 1.4159 *

.8107

  • e e e e. e e.. 1. 8 5 0 9. *e e. 4 6 3 4. *. 1. 6 0 9 2.. *.1.

4 6 2. 4. *. 1. 6 8 3 7.. *. 1 6 9 9 5. *. 2. e. 6 8 2 3

  • 1....
  • 1.5900
  • eeeee.

10

  • 1.5294
  • 1.6890
  • 1.2606
  • 1.6697
  • 1.5048
  • 1.5626
  • 1.3366
  • 1.1192 *
  • e e e e e e... 1. 4 62 9...* e e 614 6
  • 1. 47 8 6
  • 1. 6 912
  • 1,. 6 4 9 9. e *e e e e. 9 0 5 3
  • 2. 2 0 6 8 *
  • 1.6268
  • 1 1

..eeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeen 11

  • 1.7725
  • 1.5615
  • 1.6729
  • 1.2477
  • 1.5422
  • 1.3173
  • 1.3441 *

.9071 *

  • 1. 4 2 9 0. *.1.6 0 8 6.. *.1. e. 47 7 6
  • 1. 9 0 5 3
  • 1 6 3 4 6 + 1. 9 4 4 9. *.1.

8 9 5 5. *.2.7 87 0.

  • eenen...
        • ee.eee.......

12

  • 1.4266
  • 1.7436
  • 1.5060
  • 1.5433 1.0453
  • 1.0164
  • 1.1513 a
  • 1.7587
  • 1.4568
  • 1.6878
  • 1. 6327
  • 1.8929
  • 1.8954
  • 2.3832
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.5690
  • 1.5037
  • 1.5647
  • 1.3195
  • 1.1535 *

.9371 *

.6683 *

. 1 5807

  • 1.6790.*. 1. 6466.*. 1. 9413.*.1. 8929.*. 2. 1640..*.3. 4771..*

r

. eeeeeeeeeee.

14

  • 1.1813
  • 1.4159
  • 1.3366
  • 1.3452
  • 1.0474 *

.6758 *

  • 1.7752.e*e.1. 7000
  • 1. 9053..*e. 8938
  • 2.3777
  • 3.4423
  • 1 ese** e

..ee..

e

.eeeeeeeeeeeeeeeeeee**e 15 *

.9746 *

.8107

  • 1.1192 *

.9071'* F-SUB-Q

  • 2.0521
  • 2.6827
  • 2.2068
  • 2.7870
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene

~

~

Catawba 2 Cycle 7 Core Operating Limits Report Page 75 of 144 Appendix A TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUD-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 415 EFPD,- THIS IS LEVEL 14 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

E D

C B

1 e e e e e e e e e e e...........F... e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e 1.5690

  • 1.5337
  • 1.7714
  • 1.4094
  • 1.5776
  • 1.3120
  • 1.1138
  • 8*

.8836

  • e e e e e e e e e e e e e e e e e e e e. 82.13.*e e e e. 5 92 4
  • 1. 9 67 8 * - 1.7 637
  • 1. 9 8 9 4
  • 2. 2 911
  • j
  • 2.3860
  • 1.7696
  • 1 1

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen eeeee 9

  • 1.5690
  • 1.2981
  • 1.7061
  • 1.5508
  • 1.7265
  • 1.4844
  • 1.4373 *

.8547 *

  • 1.7696
  • 2.0651
  • 1.6278
  • 1.8042
  • 1.6366 8 1.8910
  • 1.8986
  • 2.9890
  • eeeeeeeeeeeeeeeeeeeeeeeeeeenseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.5337
  • 1.7061
  • 1.4608
  • 1.6783
  • 1.4908
  • 1.5401
  • 1.3184
  • 1.1224 *

. 1. 8 213.. *.1. 6 27 8. *. 1. 810 4.. *..' 1. 6 4 5 5. *.1.

9 0 2 0. *. 1. 8 4 0 9. *. 2. e.14 6 3

  • 2. 4 6 5 4.
  • e*ee..

eeeeee.

11

  • 1.7714'* 1.5530
  • 1.6004
  • 1.2745
  • 1.5347
  • 1.2766
  • 1.3066 *

.8836 *

  • 1. 5924.*.1. 8035.*.1. 6442..*.2. 1304.*..1 02.43.*.2. 1842..*. 2. 1208.*. 3. 1150.*

12

  • 1.4094
  • 1.7350
  • 1.4940
  • 1.5358 *

.9928

  • 1.1053
  • 1.0025 *
  • 1.9678
  • 1.6303
  • 1.8986
  • 1.8223
  • 2.1413
  • 2.1433
  • 2.7021
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.5776
  • 1.4876
  • 1.5422
  • 1.2777
  • 1.1074
  • 8911 *

.6340 *

. 1. 7 637..*. 1.e. 8 860

  • 1. 83 8 5
  • 2.1009
  • 2.140 0
  • 2. 45 8 3
  • 3. 9 3 69
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.3120
  • 1.4373
  • 1.3195
  • 1.3077
  • 1.0046 *

.6405

  • e 1.9894
  • 1.8995 *.2.1455
  • 2.1198
  • 2.6969
  • 3.8959
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1138 *

.8547

  • 1.1224 *

.8836

  • 2.2 911
  • 2.9911
  • 2.4668
  • 3.1150
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

AT 50% POWER, 415 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E-D C

B A

    • eeeeeeeeeee.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8 *

.9018

  • 1.6108
  • 1.5690
  • 1.8089
  • 1.4298
  • 1.6236
  • 1.4137
  • 1.2209 *

. 2. 59 8 9.*.1. 9 3.58..*.2.023 3 + 1.73 6 6

  • 2.1221
  • 1. 9 3 41
  • 2.2152
  • 2. 53 3 2 * '

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6108
  • 1.3527
  • 1.7650
  • 1.5840
  • 1.7629
  • 1.5101
  • 1.4940 *

.9232 *

  • 1 9358
  • 2.2984
  • 1.8094
  • 1.9887..*.1. 7716.*. 2. 0562..*.2. 1110.*. 3. 2923..*.

e....eeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.5690
  • 1.7650
  • 1.5669
  • 1.7468
  • 1.5123
  • 1.5594
  • 1.3377 *.1.1578
  • 2.0233
  • 1.8094
  • 2.0275
  • 1.8301
  • 2.0621
  • 1.9768
  • 2.2917
  • 2.6618
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.8089
  • 1.5851
  • 1.7479
  • 1.3238
  • 1.5583 *.1.2756
  • 1.3120 *

.8900

  • eeeeeeeeeeeeeeeeeeeeeeee.1. 9968.*eeee.3857
  • 2.3027
  • 3.3605 *'

1.8286

  • 2.3574
  • 2

. 1. 7366.*. 1e.9850

  • eeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.4298
  • 1.7704
  • 1.5155
  • 1.5594 *

.9939

  • 1.0988 *

.9971 *

. 2. 1221.*. 1. 7636..*. 2. 0581...*.2. 9949.*. 2. 3717..*.2. 3656.*.2. 9771..*.

13

  • 1.6236
  • 1.5133
  • 1.5615
  • 1.2766
  • 1.0999 *

.8804 *. 6276 *

  • 1 9 3. 41.*. 2. 0 5 2 2..*. 1. 97 41.e *e e e e. 3 8 31.. *. 2. 3 6 2 3. *. 2. 7 0 8 3. *. 4. 3112..*. -

2 e.

14

  • 1.4137
  • 1.4940
  • 1.3377
  • 1.3130 *

.9982 *

.6340 *

  • 2. 2152..*.2. 1120..*.2. 2917..*.2. 3015
  • 2.9714
  • 4.2674 *.

i eeeeeeeeeeeeeeeeeeeeeee 15

  • 1.2209 *

.9221

  • 1.1567 *

.8900

  • 2.5332
  • 3.2949
  • 2.6635
  • 3.3632
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeee****eeeeeeeeeeee l

--~

,n n

T Catawba 2 Cycle 7 Core Operating Limits Report Page 76 of 144 Appendix A 4

TABLE 1 (CORTINUED) j F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION i

AT 50% POWER, 415 EFPD, THIS IS LEVEL 12 OF 18 4

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F-E D

B-A eeeeee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.....C..eeeeeeeeeeeeeeeeeeeese 8*

.8879

  • 1.5894
  • 1.5412
  • 1.7789
  • 1.3987 a 1.6001
  • 1.4052
  • 1.2242
  • 2.1914
  • 2.2401
  • 1.9264
  • 2.3
  • 2.1196
  • 2.4176.* 2.7665
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e 739 e 2.9656
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9
  • 1.5894
  • 1.3334
  • 1.7436
  • 1.5551
  • 1.7329
  • 1.4812
  • 1.4823 *

.9211 *

  • 2.1914
  • 2.5570..*.1 9892..*.eee.2127
  • 1.9675
  • 2.2826
  • 2.2838
  • 3.5920 *'

2 eseeeeeeeeeee..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.5412
  • 1.7447
  • 1.5476
  • 1.7275
  • 1.4801
  • 1.5283
  • 1.3109
  • 1.1438
  • 4 2.2401
  • 1.9892
  • 2.2506
  • 2.0067
  • 2.2996
  • 2.2070
  • 2.5455
  • 2.8999
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7789
  • 1.5562
  • 1.7286
  • 1.3034
  • 1.5272
  • 1.2402 8 1.2809 *

.8707

  • l

. 1. 9264.*. 2. 2093..*. 2. 0057..*.2. 6025.*.2. 2378..*. 2. 7027

  • 2.5911
  • 3 7608..*

eeeeeeeeeeeeee..

4 12

  • 1.3987
  • 1.7404
  • 1.4823
  • 1.5283 *

.9693

  • 1.0667 *

.9682 *

  • 2. 3739
  • 1.9586
  • 2.2959
  • 2.2355
  • 2.6763
  • 2.6542
  • 3.3484
  • 1 e.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.6001
  • 1.4844
  • 1.5305
  • 1.2413
  • 1.0689 *

.8536 *. 6073 *

  • 2.1196
  • 2.2778
  • 2.2048
  • 2.7010
  • 2.6510
  • 3.0408
  • 4.8338
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.4052
  • 1.4823
  • 1.3109
  • 1.3809 *

.9693 *

.6137

  • e.2. 417 6..*. 2. 2 8 3 8.. *. 2. 5 4 5 5.*.
2. 5 911.*. 3. 3 4 3 2..*. 4. 7 8 3 5.*.

.ee.

15

  • 1.2242 *

.9211

  • 1.1438 *

.8697

  • 2. 7665.*. 3. 5950.*.eee.9018
  • 3.7640
  • M-SUB-Q 2

e.

eeeeeeeeeeeeeee AT 50% POWER, 415 EFPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM) e H

0 F

E D

C B

A seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8 *

.8686

  • 1.5455
  • 1.4919
  • 1.7254
  • 1.3516
  • 1.5540
  • 1.3666
  • 1.1974 *
  • 3.4867
  • 2 5086
  • 2.5757
  • 2.2104
  • 2.7602
  • 2.4149
  • 2.7162
  • 3.0661
  • eeeeeeeeeeee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
  • 1.5455
  • 1.2927
  • 1.6933
  • 1.5037
  • 1.6793
  • 1.4330
  • 1.4437 *

.8986 *

  • 2.5086
  • 2.9525
  • 2.2730
  • 2.5440
  • 2.2576
  • 2.6146
  • 2.5803
  • 4.0399
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese f

10

  • 1.4919
  • 1.6933
  • 1.4973
  • 1.6761
  • 1.4298
  • 1.4801
  • 1.2691
  • 1.1138 *

. 2. 57 57.. *.2.2 7 3 0..*. 2. 5 6 81. *.2.

2 8 8 6. *. 2. 6 514.. *e e e e. 5 3 6 5

  • 2. 915 5
  • 3 2 772..*.

2 eeeeeeeeeeeeeee..

11

  • 1.7254
  • 1.5037
  • 1.6772
  • 1.2616
  • 1.4801
  • 1.1984
  • 1.2413 *

.8429 *

  • 2.2104
  • 2.5440
  • 2.2862
  • 3.0044
  • 2.5773 *-3.1349
  • 2.9858
  • 4.3151 *
      • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeee 12
  • 1.3516
  • 1.6868
  • 1.4319
  • 1.4823 *

.9436

  • 1.0357 *

.9371 *

  • 2.7602
  • 2.2483
  • 2.6482
  • 2.5742
  • 3.0976
  • 3.0529 + 3.8568
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen i

13

  • 1.5540
  • 1.4362
  • 1.4823
  • 1.1995
  • 1.0378 *

.8300 *

.5880 *

  • 2.4149
  • 2.609 5.5976
  • eeeeeeeeeeeeeee.9
  • 2. 5350
  • 3. 1326
  • 3.0486
  • 3.4908 *
  • ee.

ee...

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.3666
  • 1.4426
  • 1.2691
  • 1.2413 *-.9382 *

.5944 *

  • 2.7162
  • 2.5819
  • 2.9155
  • 2.9858
  • 3.e.8500
  • 5.5340
  • eeeeeeeeeeeeeee eeeeee.eeeeeeeeeeeeeee e3eeeeeee eeeee 15
  • 1.1974 *

.8975

  • 1.1138 *

.8429

  • 3. 0 661
  • 4. 0 43 7
  • 3. 27 9 6
  • 4. 319 4
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeee p

w

Catawba 2 Cycle 7 Core Operating Limits Report Page 77 of 144 Appendix A J

TABLE 1 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 415 EFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) 1 0

F B

B A

e...H..... e e e e e e e e e e e e e e e e e e e e e e e........D. e e e e e * * *C eeeeeeeeeeeeeeeeeeeeeee.

1. 5 3 37
  • 1. 472 6 + 1.7 082
  • 1. 3 3 3 4
  • 1. 5401
  • 1. 35 48
  • 1.1931
  • 8 *

.8750 *

  • 3. 8 3 8 4. *.2.7 9 8 7..*.3.0 0 0 3..*.2.5 6 3 5. *.3.2 414..*.2.7 8 4 3.*.3. 112 4.
  • e e e. 47 4 3
  • 3 eeeeen j

e.

i 9

  • 1.5337
  • 1.2777
  • 1.6793
  • 1.4833
  • 1.6654
  • 1.4159
  • 1.4330 *

.8932 *

7.. *. 3. 4 4 0 5. *.2. 6 3 21
  • 2. 9 6 3 3...*. 2. 614 6.
  • 3. 0 2 9 6.. *.2.

9 5 3 2..*. 4. 6 2 91.. *e

  • 2.798

... ee.

ee..

. e eeeeee.

l 10

  • 1.4726
  • 1.6793
  • 1.4769
  • 1.6622
  • 1.4116 *'1.4662
  • 1.2574
  • 1.1096 *

. 3. 0003..* 2. 6321..*.2. 9879..*.2. 6498

  • 3.0880
  • 2.9352
  • 3.3611
  • 3.7380
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

s t

11

  • 1.7082
  • 1.4833
  • 1.6622
  • 1.2488
  • 1.4673
  • 1.1977
  • 1.2338 *

.6386 *

  • 2. 5635.*.2. 9633..*.2. 6482.*.3 5190.*. 2. 9096..*. 3. 5338.*. 3. 4384
  • 4.9344..*.

e.

eeeeeeeeeeee 12

  • 1.3334
  • 1.6718
  • 1.4137
  • 1.4683 *

.9478

  • 1.0367 *

.9339

  • e.3. 2414..*.2. 6036
  • 3. 0836..*.2. 9076.*e.3. 4521..*. 3. 4096.*.4 2980.*

.ee.

13

  • 1.5401
  • 1.4180
  • 1.4673
  • 1.1877
  • 1.0378 *

.8354 *

.5800 *

  • e.**ee.

. 3. 0254.*. 2. 9332..*. 3. 5309

  • 3.4033
  • 3.8995 *eeeeeeeeeeeeeeeeeeeeeeeee. 3168 *
  • 2.7843
  • 6 eeeeee 14
  • 1.3548
  • 1.4319
  • 1.2574
  • 1.2338 *

.9350 *..5944 *

  • 3. 1124.**2.9552..*. 3. 3637..*eeee.4384
  • 4.2938
  • 6.2436
  • 3

. e

  • ee..

eeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1931 *

.8932

  • 1.1085 *

.8375

  • 3. 4743..*.ee 6341..*.3 7413
  • 4.9400 ** M-8UB-Q 4

e.

e**ee...

.ee AT 50% POWER, 415 EFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H 0

F.

E D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

1.4823

  • 1.3045
  • 1.1513
  • 8*

.8472

  • 1.4812
  • 1.4148
  • 1.6440
  • 1.2788 *

. 4 2144

  • 3. 0107..*. 3. 1349.*. 2. 6960.*. 3. 4275
  • 2.9593
  • 3.3455
  • 3.7542
  • 1

..e..

.ee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9* 1.4812

  • 1.2284
  • 1.6172
  • 1.4234
  • 1.6022
  • 1.3602
  • 1.3816 *

.8600 *

  • 3 0107
  • 3.6103
  • 2.7525
  • 3.1101
  • 2. 7595..*. 3. 2259.*.3. 1670.*eeee.0260
  • 5
  • e

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeee 10

  • 1.4148
  • 1.6161
  • 1.4180
  • 1.5990
  • 1.3559
  • 1.4137
  • 1.2124
  • 1.0710
  • 3.1349
  • 2.7542
  • 3.1326
  • 2.7843
  • 3.2673 *-3.1281
  • 3.6315
  • 4.0490
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.6440
  • 1.4234
  • 1.6001
  • 1.1995
  • 1.4180
  • 1.1460
  • 1.1942 *

.8097

  • i 2.6960
  • 3.1079
  • 2.7825
  • 3.7092
  • 3.1531
  • 3.8544
  • 3.7188 *
    • ***eeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eeeeeeeeeeeeeeeeeeeeeeeee.5 3953
  • eeeee 12
  • 1.2788
  • 1.6086
  • 1.3580
  • 1.4191 *

.9200

  • 1.0089 *

.9071 *

  • 3. 4..$.7 5.*..e e e.7 472
  • 3. 2 62 3
  • 3.150 8..* e e e.77 0 6
  • 3.7156
  • 4. 67 8 6
  • 2 3

eeeeeeeeeeeeeeeeee...

eeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.4823
  • 1.3623
  • 1.4148
  • 1.1470
  • 1.0100 *

.8161 *..5719 *

  • 2. 9593.*. 3. 219.7.*. 3. 1258
  • 3.8544.*.3. 712.4.*. 4 2558..*. 6. 8987..*.

e.

eeeeeeeeee....

14

  • 1.3045
  • 1.3816
  • 1.2113
  • 1.1931 *

.9082'*

.5783

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.203.3 455
  • 3.169 3
  • 3.6315
  • 3.72

.e

  • e e e. 673 6
  • 6. 83 3 4
  • 4 e

eeeeeeeeeeeeee.

j 15

  • 1.1513 *

.8600

  • 1.0710 *

.8086

. 3. 7542..*.5. 0318.*.4 0490.*. 5. 4020..*. M-SUB-Q i

l

i Catawba 2 Cycle 7 Core Operating Limits Report Page 78 of 144 Appendix A i

TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION 2

AT' 50% POWER, 415 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

....H........G.........F........E........D.........C........B........A......

e 8*

.8547

  • 1.4919
  • 1.4201
  • 1.6536
  • 1.2820
  • 1.4908
  • 1.3098
  • 1.1610 *

. 4 0301..*.2. 8653..*.2. 9879..*. 2. 5620...*.3. 2404.*.2. 7790

  • 3. 1168.*.3. 4659..*.

i 9

  • 1.4919
  • 1.2349
  • 1.6290
  • 1.4276
  • 1.6129
  • 1.3634
  • 1.3902 *

.8664 *'

i

  • 2. 8653..*. 3. 4357..*. 2. 6193..*.2. 9613
  • 2.6099
  • 3.0360
  • 2.9512
  • 4 6385.*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

10

  • 1.4201.* 1.6290 *.1.4223
  • 1.6119
  • 1.3623
  • 1.4244
  • 1.2209 * *.0017 *
  • 2.9879.*. 2. 6193..*. 2. 9879.*.2. 6465
  • 3.1012
  • 2.9492..*. 3. 3873
  • 3.7380
  • e eeeeee

...eeeeeeeeeeeeeeeee eeeeeeeeeeeeee.

11

  • 1.6536
  • 1.4276
  • 3.6129
  • 1.2001
  • 1.4298
  • 1.1567
  • 1.2092 *

.8193 *

. 2. 5 6 2 0.*. 2. 9 6 3 3..*.2.6 4 6 5. *. 3. 5 2 51.*.

2. 9 7 3 5. *.3.5 9 2 4..*.3.4 6 07..* e e 0 02 8.. *.

5

- 12

  • 1.2820
  • 1.6194
  • 1.3634
  • 1.4309 *

.9296

  • 1.0271 *

.9232 *

  • 3.2404
  • 2.6005
  • 3.0968
  • 2.9735
  • 3.5924
  • 3.4882
  • 4.3237
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.4908
  • 1.3666
  • 1.4255
  • 1.1578
  • 1.0282 *

.8365 *-.5858.* :

2.7790

  • 3.0318
  • 2.9472
  • 3.5924
  • 3.4854 a 3.9820
  • 6.371 eneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.2 *
  • ee 14
  • 1.3098
  • 1.3891
  • 1.2199
  • 1.2081 *

.9243 *

.5923 *

  • 3. 116 8. *.2. 9 5 3 2..*.3.3 87 3. e *e e< 3. 4715..*. 4. 319 4.*.
6. 3 0 6 3. * -

e.

eee 15

  • 1.1610 *. 8654
  • 1.0806 *

.8172

  • 3. 4659.*. 4. 6385.*.3. 7413.*. 5. 0085..* N-5UB-Q 4

AT 50% POWER, 415 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1.*

BOTTOM) i e...H.........O.........F.........E.........D.........C.........B.........A......

8*

.8643

  • 1.5015
  • 1.4169
  • 1.6515
  • 1.2734
  • 1.4844
  • 1.3023
  • 1.1567
  • 3.6997
  • 2.5247
  • 2.6465
  • 2.2671
  • 2.8806
  • 2.4658
  • 2.7718
  • 3.0792
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5015
  • 1.2349
  • 1.6311
  • 1.4223
  • 1.6097
  • 1.3559
  • 1.3848 *

.8611 *

... 5 2 47.. *. 3. 0 3 81.. *. 2. 314 3.. *. 2. 6 2 7 3.. *. 2. 310 6. *. 2. 6 9 9 3. *.2.

619 3.. *. 4. 12 61. *.

  • 2 10
  • 1.4169
  • 1.6311
  • 1.4100
  • 1.6140
  • 1.3602
  • 1.4266
  • 1.2188
  • 1.0006 * -

e e e e. 4 6 5.. *.2.

314 3. *.2. 6 4 8 2. e *.2.

3 3 9 3. *.2.7 472.. *. 2. 6 0 8 3.*.3. 0 0 4 4. *. 3. 317 3.. *

(

2.6..

e 11

  • 1.6515
  • 1.4223
  • 1.6140
  • 1.2092
  • 1.4405.* 1.1674
  • 1.2177 *

.8215 *

  • 2.2671
  • 2 6273
  • 2. 3380.*.3.1168
  • 2.6353
  • 3.2428
  • 3.0618 *eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.4 429 eeeeeeeeee**

ee**

ee 12

  • 1.2734
  • 1.6161
  • 1.3623
  • 1.4416 *

.9446

  • 1.0517 *

.9403 *

. 2. 8 8 0 6.. *. 2. e. 3 02 0. *.2.

7 4 5 5. *. 2. 6 3 3 7.. *. 3. 312 2.. *. 3. 2 0 4 4.. *. 3. 9 6 01.. *.

e..

13

  • 1.4844
  • 1.3580
  • 1.4266
  • 1.1674
  • 1.0528 *

.8643 *

.6019 *

  • 2. 4658..*.2. 6943..*.2. 6083..*. 3. 2428.*. 3. 1997..*.3. 6560.*. 5. 8625.*.

e.

e.

14

  • 1.3023
  • 1.3837
  • 1.2188
  • 1.2177 *

.9414 *

.6094 *

  • 2.7718
  • 2.6209
  • 3.0065
  • 3.0618
  • 3.9565
  • 5
  • eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 7997
  • eeeee 15
  • 1.1567 *

.8611

  • 1.0796
  • 82 0 4
  • 3 0792..*. 4. 1300..*.3. 3198..*. 4 4389..*. N-8UB-Q 4

=

w

l Catawho 2 Cycle 7 Core Operating Limits Report Page 79 of 144

/4ppendix A f

TABLE 1 (CONTINUED)

F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP MARGIN) - NORMAL OPERATION AT 50% POWER, 415 BFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

G F

B D

C B

A

....H....... e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.... e e e e e e e e e e e e e e e e e e e e e e e e e e e i

l 8*

.9221

  • 1.5240
  • 1.4159
  • 1.6451
  • 1.2627
  • 1.4726
  • 1.2884
  • 1.1449 *

. 3. 2 7 7 2.. *. 2. 2 5 6 5. *.2.

3 8 31. *. 2. 0 4 07.. *.2.

6 0 5 2..*e e. 2 2 8 6. *. 2. 511. e e *e. 2. 7 915.

  • 2 5

e 9

  • 1.5240
  • 1.2424
  • 1.6311
  • 1.4159
  • 1.6011
  • 1.3462
  • 1.3730 *

.8504 *

  • 2. 2.565..*. 2. 7282..*.2. 0799..*.2. 3687.*.2. 0839.*. 2. 4422.*. 2. 3700.*. 3. 7510..*
  • 1.0742 *

)

10

  • 1.4159
  • 1.6311
  • 1.4159
  • 1.6140
  • 1.3602
  • 1.4276
  • 1.2156

. 2. 3831..*. 2. 0799.*. 2. 3844.*. 2. 1021..*. 2. 4757..*.2. 3469.*.2. 7128..*.3 0003.*.

i i

11

  • 1.6451
  • 1.4159
  • 1.6140
  • 1.2124
  • 1.4662
  • 1.1877
  • 1.2306 *

.8215 *

  • 2.0407..*.2.3700
  • 2.1021
  • 2.8041
  • 2.3558
  • 2.8999
  • 2.7438
  • 4.0004
  • e ee...

.... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2627
  • 1.6076
  • 1.3612
  • 1.4673
  • 1.0142
  • 1.1063 *

.9703

  • 2.6052
  • 2.0759
  • 2.4728
  • 2.3546
  • 2.9372
  • 2.8503
  • 3.4967 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13
  • 1.4726
  • 1.3473
  • 1.4276
  • 1.1888
  • 1.1074 *

.9296 *

.6308 *

. 2. 2286.*. 2. 4300..*. 2. 3.469.* 2. 8999.*.2. 8484.*. 3. 2574.*. 5 2514.*

14

  • 1.2884
  • 1.3730
  • 1.2145
  • 1.2295 *

.9714 *

.6372 *

  • 2. 5115.. *. 2. 3 7 0 0.. *.2.

7 2 4 5.. *. 2. 7 4 5 5. *e e e e. 4 9 3 9

  • 5.19 47
  • 3 e.

eeeeeeeeeeeeee.-

15

  • 1.1449 *

.8504

  • 1.0731 *

.8204

  • 2.7915
  • 3.7542
  • 3.0024
  • 4.0078
  • N-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee AT 50% POWER, 415 EFPD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

D C

B A

....H.........O.........F.........B..... e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.

8* 1.0946

  • 1.6204
  • 1.4758
  • 1.7082
  • 1.3045
  • 1.5230
  • 1.3291
  • 1.1824 *
  • *
  • e e. 4 2.. *.1 9 612.. *. 2. 0 87 9.. *. 1. 7 8 9 5.. *. 2. 2 9 47.. *. 1. 9 6 3 0.. *. 2. 219 5. *. 2. 4 6 5 8.
  • e 2.75 9* 1.6204
  • 1.3066
  • 1.7040
  • 1.4716
  • 1.6622
  • 1.3955
  • 1.4201 *

.8782

  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.9 9. *. 1. 8 2 8 8.. *.2.

15 3 3.. *.2.0 8 8 9..

  • e e e. 317 3 *
  • 1.9612
  • 2.3804
  • 1.8173
  • 2.07 3

. e eeeee.

10

  • 1.4758
  • 1.7040
  • 1.4737
  • 1.6858
  • 1.4191
  • 1.4930
  • 1.2649
  • 1.1138 *
  • 2 0879..*.1. 0173
  • 2.0899
  • 1. 8365
  • 2.1684
  • 2.0542
  • 2.3817
  • 2.6417 *
  • e

. eeeeeeeeeeeen.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.7082
  • 1.4705
  • 1.6868
  • 1.2734
  • 1.5626
  • 1.2734
  • 1.2991 *

,8579 *

  • 1.7895
  • 2.0809
  • 1.8365
  • 2.4463
  • 2.0407
  • 2.4885
  • 2.3883
  • 3.5080
  • i emeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeeeeeeeee.

)

12

  • 1.3045
  • 1.6686
  • 1.4201 = 1.5637
  • 1.2145
  • 1.2768
  • 1.0528
  • e. 2. 2 9 47. *. 1. 8 219.. *.2.

16 6 2.. *. 2. 0 3 9 7.. *. 2. 47 9 9.. *. 2. 4 0 4 2.. *. 2. 9 7 9 6.. *.

13

  • 1.5230
  • 1.3966
  • 1.4930
  • 1.2734
  • 1.2798
  • 1.1021 *

.6972 *

  • 1. 9630..*. 2. 1501.*.2. 0542..*.2. 4870..*. 2. 4029
  • 2.7507
  • 4.4208
  • e.

eeeeeeeeeeeeeee**eeeeee.

14

  • 1.3291
  • 1.4191
  • 1.2638
  • 1.2981
  • 1.0539 *

.7047

  • 1 e.2.2195
  • 2.0899
  • 2.3844
  • 2.3896
  • 2.9755
  • 4.3717
  • l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1824.*

.8771

  • 1.1138
  • 8568
  • F - S UB-Q 2.6449
  • 3.51
    • ee.650'* 3.3198 *

. e e e e e e e e e e e e e e e e e e e e e e e e e. 37..*. M-SUB-Q

  • 2.4 l

w

.s--

Catawba 2 Cycle 7 Core Operating Limits Report Page 110 of 144

' Appendix A-1 TABLE 1 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - NORMAL OPERATION AT 50% POWER, 415 EFPD, THIS IS LEVEL' 4 OF 18 (LEVEL 18 = TOP OF COREi T.EVEL 1 m BOTTOM)

H O

F E

D C

B A-eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

8

  • 1.1738
  • 1.6558
  • 1.4844
  • 1.7147
  • 1.3045
  • 1.5230
  • 1.3291
  • 1.1802 *

. 2. 5291

  • 1. 7619..... 1. 9195.*.1. 6511
  • 2.1248
  • 1.8173
  • 2.0572
  • 2.2898 *

..e**e

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6558
  • 1.3227
  • 1.7136
  • 1.4769
  • 1.6675
  • 1.4019
  • 1.4234 *

.8739 *

. 1 7619

  • 2.1738
  • 1.6708
  • 1.9187
  • 1.6910
  • 1.9928
  • 1.9332
  • 3.0902 *-

+

. eeeeeeeeeeeeeeeeeeeeeee**eneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10

  • 1.4844
  • 1.7136
  • 1.4833
  • 1.6965
  • 1.4309
  • 1'.5080
  • 1.2723
  • 1.1160 *
  • 1.9195
  • 1 eeeeeeeeeeee 6714
  • 1.9204
  • 1.6884
  • 1.9919
  • 1.8836
  • 2.1936
  • 2.4477
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7147
  • 1.4758
  • 1.6975
  • 1.2927
  • 1.6033
  • 1.3109
  • 1.3216 *

.8632 *'

e.1. 6511.*.1. 9195.*.1. 6877...*.2. 2343

  • 1.8234
  • 2.2390
  • 2.1716
  • 3.2380.*

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

12

  • 1.3045.* 1.6708
  • 1.4319
  • 1.6044
  • 1.3216.* 1.3655
  • 1.0f3.3 *
  • 2.1248
  • 1.6844
  • 1.9901
  • 1. 8 2.19.. *.2.2 5 0 6. *.2.17 4 9. *.2.6 8 9 3...*.
  • eeeeeeeeeeeeeeeeeeeeeeeeee..

13

  • 1.5230
  • 1.4019
  • 1.5080
  • 1.3109
  • 1.3677
  • 1.1920 *

.7294,*

e.1. 8.173..*. 1. 9 9 01.. *.1.

8. 8 3 6
  • 2 2. 37 8.*.2.17 27.. *.2.47 9 9.*.. 4 0 3 01. *.

14

  • 1.3291
  • 1.4223
  • 1.2713
  • 1.3205
  • 1.0924 *

.7379 *

  • 2.0572
  • 1.9341
  • 2.1947
  • 2.1727
  • 2.6859
  • 3.9856
  • eeeeeee**e**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees-15
  • 1.1802 *

.8739

  • 1.1149 *.8622
  • 2.2898
  • 3.0924 *.

s

  • eeeeeeeeeeeeeeeee. 2. 4504
  • 3.2404
  • M-8UB-Q eeeeeeeeeeeeee AT -50% POWER, 415 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

.... H......... G.. e...... F........ E...... e e e. e 'e., e e.. C......... B. e e...... A..... e l

D 8

  • 1.1920
  • 1.6729
  • 1.4919
  • 1.7211
  • 1.3141
  • 1.5347
  • 1.3473
  • 1.1942 *

. 2. 2766

  • 1.6220
  • 1.7888
  • 1.5456
  • 1.9855
  • 1. 6990.*.1 9178.*.2. 1384.*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

9

  • 1.6729
  • 1.3366
  • 1.7211
  • 1.4833
  • 1.6750
  • 1.4191
  • 1.4426 *

.8868 *

  • 1.6220
  • 1 eeee**ee.. 2. 0048
  • 1.5618.* 1. 7932..*. 1. 5864.*eeee.8499
  • 1.8007
  • 2.8787
  • i eeeeee....

ee eeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.4919
  • 1.7200
  • 1.4940
  • 1.7040
  • 1.4448
  • 1.5294-* 1.2927
  • 1.1278
  • i

... 7 8. 8 8

  • 1. 5 618.. *.^ 1. 7 8 8 8. *.1.

57 6 6. *. 1. 8 4 8 3. *. 1 7. 42 7.. *.2.

0 2 9 2.. *. 2 *. 2 8 6 2..* '

  • 1
  • ee.

11

  • 1.7211
  • 1.4833
  • 1.7050
  • 1.3109
  • 1.6311
  • 1.3420
  • 1.3484 *

.8750 *

]

  • 1.5456 *

...eee....

1. 7940
  • 1.5760 *

.. 2.e.0513

  • 1.6695
  • 2.0311 aeeeeeeessossseeseeeeeeeeeeeeeeeee.3. 0044.

' l 1.9892 *

.eeeeee****

.e i

12

  • 1.3141
  • 1.6793
  • 1.4459 1.6322
  • 1.3634
  • 1.4148
  • 1.1256
  • j
  • 1 9855.*. 1 5794.*. 1. 8.467..*. 1 6689
  • 2.0207
  • 1.9489
  • 2.4203
  • j e..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

(

13

  • 1.5347
  • 1.4201
  • 1.5294
  • 1.3420
  • 1.4169
  • 1.2424 *

.7593 *

  • 1.6990
  • 1.8491
  • eeeeeeeeeeeeeeee... 1. 7420.*. 2. 0302
  • 1.9471
  • 2.2252
  • 3.5953 *-

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

14

  • 1.3473
  • 1.4416
  • 1.2927
  • 1.3473
  • 1.1267 *. 7690
  • 1.9128
  • 1.8014
  • 2.0311
  • 1.9901
  • 2.4176
  • 3.5541
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1942 *

.8857

  • 1.1267 *

.8739

  • 2.13 84
  • 2. 8 806
  • 2.2 886
  • 3.000 6
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-e-

I i

i Catawha 2 Cycle 7 Core Operating Limits Report Page 81 of 144 Appendix A l

TABLE 1 (CONTINUED)

.'l F-SUS-Q & M-SUB-Q VALUES (F-SUB-Q OP MAROIN) - NORMAL OPERATION q

l AT 50% POWER, 415 BFPD, THIS Is LEVEL 2 OF 18 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

O F

E A

e...He e e e e e e e e e e e e e e e e e e e e e e e e e e e........D.........C.........B...... e e e e e e e e.

8* 1.0849

  • 1.5026
  • 1.3495
  • 1.5476
  • 1.2081
  • 1.4159
  • 1.2681
  • 1.1010
  • 0680 *-1. 7619.*.1.9533
  • 2.2320 *
  • 2.3674
  • 1.7030.* 1.8845
  • 1.6380
  • 2.......

.... eeeeeeeeeeeeeeeee e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

i 9

  • 1.5026
  • 1.2188
  • 1.5476
  • 1.3398
  • 1.5144
  • 1.3184
  • 1.3398 *

.8386

  • l
  • 1. 70.30
  • 2.e.0839
  • 1.6517
  • 1.8952
  • 1.6663
  • 1.9060
  • 1.8594
  • 2.9313
  • t

.... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10

  • 1.3495
  • 1.5465
  • 1.3516
  • 1.5337
  • 1.3184
  • 1.4105
  • 1.2092
  • 1.0324 *

. 1. 8845.*. 1 6523..*. 1. 8845.*.1 6682..*. 1. 9281.*.1. 7992..*. 2. 0769.*. 2. 4002.*

l 11

  • 1.5476
  • 1.3388
  • 1.5347
  • 1.2070
  • 1.4833
  • 1.2434
  • 1.2434 *

.8075

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.2. 0523
  • 3.1191 *
  • 1.6380
  • 1.8952
  • 1.6669
  • 2.1134
  • 1.7343
  • 3.0789
  • eeeeeeeeeeeeee.

12

  • 1.2081
  • 1.5208
  • 1.3205
  • 1.4855
  • 1.2595
  • 1.3152
  • 1.0560 *
  • 2.0680
  • 1.6599
  • 1.9255
  • 1.7330
  • 2.0719
  • 1.9864
  • 2.4602
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen...eeeeeeeeeeeeeeeeeeeeeeeees 13
  • 1.4159
  • 1.3195
  • 1.4116
  • 1.2434
  • 1.3173
  • 1.1652
  • 7240 *
  • ee 7619.
  • 1 90.52..*.1. 7984.*. 2. 0779.*. 1. 9846
  • 2. 2448.*.3. 5894.*.
  • 1 ee..

e l

14

  • 1.2681
  • 1.3388
  • 1.2092
  • 1.2434
  • 1.0501 *

.7326

  • 1.9533
  • 1.8602
  • 2.0779
  • 2.0533
  • 2.4574
  • 3.5511
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1010 *

.8375

  • 1.0314 *

.8065

  • 2.9332 eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.13..* M-SUB-Q
  • 2.4015
  • 3.12 i

AT 50% POWER, 415 EPPD, THIS IS LEVEL ' 1 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM) l e...H.... ee. 0.eeeeeee.Fe e e e e e e e e e....... D......... C......... B......... A......

E 8*

.7508 *

.6801 *

.8964 *

.7101 *

.8397

  • 1.0067 *

.9157 *

.7465 *

  • 3. 2501..*.3. 5805..*.2. 7231.*. 3. 4140.*. 2. 8634.*.2. 3962..*. 2. 6209
  • 3.2021 *-

e.

ee eeeeeeeeeeeeee.

9*

.6801 *

.8311 *

.7079 *

.8943 *

.7186 *

.9318 *

.9650 *

.6105 *

  • 3.5805
  • 2.9293
  • 3.4330
  • 2.7282
  • 3.3637
  • 2.6083
  • 2.4999
  • 3.9207
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 10 *

.8964 *

.7079 *

.8986 *

.7069 *

.9061

  • 1.0025 *. 8600 *

.4402

  • I l

. 2. 7 2 31.. *. 3. 4 3 3 0 *. 2. 7 2 4 8. *.3.

4 411. *.2.7 010...*.2.4 3 9 4. *. 2. 8 3 3 5.*.

5. 4 4 2 7.. *e l

11 *

.7101 *

.8943 *

.7079 *

.8354 *

.6972 *

.8718 *

.8654 *

.5687

  • l
  • 3.4140
  • 2.7282
  • 3.4384
  • 2.9293
  • 3.5309
  • 2.8409
  • 2.8559
  • 4.2853
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12 *

.8397 *

.7208 *

.9071 *

.6983 *

.8632 *

.9168 *

.7422

  • l 2.8634
  • 3.3532
  • 2.6976
  • 3.52 e e e e e e e e e e e e e e e e e e e e e e e e e e e e ee e e.80
  • 2 89 9 9..*.
2. 7 507
  • 3.37 41
  • I eeeeee eeeeeeeeeeeeee.

13

  • 1.0067 *

.9328

  • 1.0035 *

.8718 *

.9178 *

.8140 *

.5173 *

  • 2. 3962.*.2. 6052
  • 2. 4300..*. 2.8391
  • 2. 7472..*. 3. 1124.*.4. 8798.*.

.ee4e...

14 *

.9157 *

.9639 *

.8600 *

.8654 *

.7433 *

.5237

  • i eeeeeeeeeeeeeeeee.59.* 3. 3689
  • 4.8138
  • I
  • 2.6289.*. 2. 5028
  • 2.8335
  • 2.85 eeeeee.

..eeeeeeeeee.

15 *

.7465 *

.6094 *

.4391 *

.5676

. 3. 2021.*.3.9243.*. 5. 4427

  • 4.2895
  • M-sUB-Q sene......

.. eeeeeeeeeee.

4

i. -

N 1

c i

Catawba 2 Cycle 7 Core Operating Limits Riport Page 82 0f 144 Appendix A TABLE 2 F-SUB-Q & N-SUB-Q VALUES (P-SUB-Q OP KARQ1N) - POWER ESCALATION AT 100% POWER, 4 EPPD, THIS Is LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F 1B D

C B

A e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8*

.3813 *

.2945 *

.5644 *

.3502 *

.5698 *

.6544 *

.6148 *

.4798

  • e 2. 7133
  • 3.8753
  • 2.1069
  • 3.3818..*. 2. 0799..*. 1 7983..*.1 9195..*. 2. 4357.*

eeeeeeeeeeeeeeeeeeeeeeeeee..

9*

.2945 *

.5098 *

.3406 *

.5987 *

.3834 *

.6265 *

.6297 *

.4230 *

  • 3. 8753.*.2. 3.085.*.3. 4776..*. 1. 9691..*eeee.0699
  • 1. 8809.*. 1 8613
  • 2. 7608.*

3 e.

eeeee..

. eeeeee.

10 *

.5644 *

.3406 *

.5826 *

.3566 *

.6062 *

.6351 *

.5805 *

.2410

  • e. 2. 10 6 9. *. 3. 47 0 0..*. 2. 0 0 8 8.
  • 3. 2 7 7 5.. *.1.

9 3 3 6. *. 1. 8 2. 9 2..

  • 2. 016 5. *. 4 e. 8121 *

.ee eeee.

11 *

.3502 *

.6008 *

.3577 *

.5633 *

.3588 *

.5805 *

.5484.*

.3963 *

  • 3. 3818..*. 1. 9621..*. 3. 2650.e*eee.9864
  • 3.0690
  • 1.9215
  • 2.0741
  • 2. 9059.*

1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12 *

.5698 *

.3856 *

.6083 *

.3599 *

.5355 *

.5205 *

.4798 *

  • 2. 0799..*.3. 0521.*.1. 92.65.*. 3. 0631.*. 1 8742..*. 1. 9.472..*.2. 2.984..*

13 *

.6544 *

.6297 *

.6372 *

.5816 *

.5226 *

.4712 *

.3277 *

  • 3.2970 *
  • 1 7983.*.1.8742
  • 1.8250
  • 1.9168
  • 1.9424
  • 2.1069
  • ee

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14 *

.6148 *

.6297.*

.5816 *

.5494.*

.4819 *

.3342

  • 1.9195
  • 1.8610
  • 2.0118
  • 2.0686
  • 2.2884
  • 3.2305 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.4798 *

.4230 *

.2420 *

.3973

.eeeeee 61.*. M-SUB-Q

  • 2.89
  • 2.4357..*. 2. 7615.*. 4 8099 eeeeee.

AT 100% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 8*

.5633 *

.8332 *

.8354 *

.9286 *

.8129 *

.9975 *

.9168 *

.7775

  • 1.+.1. 7691..*.1 7902..*. 1. 6049.*.ee 8292..*. 1. 6455
  • 1.6102
  • 1.8801
  • 1 2.406..

.eeeeeeeeeeeeeeeeeeeeee.

eeeeee.

9*

.8332 *

.7433 *

.9082 *

.8675 *

.9650 *

.9350 *

.9104 *

.6340 *

. 1 76.91..*.1. 9911..*.1. 6397..*. 1. 7179..*. 1. 5293.*. 1. 5788..*. 1. 6143

  • 2.3127
  • eeeeeeeeeeeeee.

10 *

.8354 *

.9093 *

.8771 *

.9307 *

.9018 *

.8911 *

.8761 *

.7036

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.24.*.1 6344.*. 1. 6.538.*.1 6751.*.2. 0691.*.
  • 1.7902
  • 1.6371
  • 1.6957
  • 1.56 11 *

.9286 *

.8707 *

.9328 *

.8022 *

.9382 *

.8729 *

.8504 *

.6030 *

  • 1.6049
  • 1.7120
  • 1.5601
  • 1.7971..*.1. 5377..*.1. 6523..*. 1. 686.8.*. 2. 4066.*.

eseeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12 *

.8129 *

.9693 *

.9061 *

.9414 *

.7915 *

.8354 *

.7668

  • e.1. 8292.*. 1. 5223..*.1. 6277..*.1. 5330..*.1. 6100
  • 1.6316
  • 1.8429 *

. ee

.eeeeeeeeeeeeeeeeeeeee.

13 *

.8975 *

.9371 *

.8954 *

.8750 *

.8386 *

.8032 *

.5055 *

  • 1. 6455..*. 1. 5751.*.1. 6469..*. 1. 6469..*. 1. 6263..*. 1. 6794.*. 2. 7492..*.

14 *

.9168 *

.9125 *

.8782 *

.8536 *

.7700 *

.5173 *

  • 1. 6102
  • 1. 6127..*.1. 6709.*..1. 6821.*. 1. 8356.*.2. 6885.*e e.

15 *

.7775 *

.6330 *

.7047 *

.6051

. 1. 8001.*.2. 3131.*. 2. 0650. *.2. 3900.*. M-SUB-Q e

e

Catawba 2 Cycle 7 Core Operating Limits Report Page 83 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 100% POWER, 4 EFPL, THIS Is LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G........F.........E.........D.........C.........B........A......

8*

.7765

  • 1.1010
  • 1.0903
  • 1.1974
  • 1.0153
  • 1.1085
  • 1.1149 *

.9V57

  • 1 1.4724
  • 1.4571
  • 1.6497 *

... 0796... 1. 4 8 47. *.1. 510. 8. *.1.3 67 9.. *e e e e. 6 0 3 6 *

  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9* 1.1010 *

.9596

  • 1.3910
  • 1.1213
  • 1.2134
  • 1.1535
  • 1.1256 *

.7647 *

. 1. 4847..*.1. 6979

  • 1.3778
  • 1.4643
  • 1.3414
  • 1.4127
  • 1.4389
  • 2.0991
  • e****eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.0903
  • 1.1920
  • 1.1428
  • 1.2134
  • 1.1363
  • 1.1256
  • 1.0817 *

.8986

  • e.1. 5108... 1. 3767..*.1. 4349.*. 1. 3328..*.1.e.4302
  • 1.4460
  • 1.4969.*.eee.7854 1

eeeeeeeeeeeeeeeeee...

eee...

11

  • 1.1974
  • 1.1245
  • 1.2156
  • 1.0282
  • 1.2124
  • 1.1021
  • 1.0817 *

.7604

  • 1.3303
  • 1.4602
  • 1.4754
  • 2.1080
  • e.1.3679**ee**ee.1. 4602..*.1 3311.*.1. 5648 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen.

12

  • 1.0153
  • 1.2188
  • 1.1417
  • 1.2145
  • 1.1224
  • 1.1074 *

.9714

  • e 1 6036.*.1. 3.354.*. 1. 4252.*.1. 3302
  • 1.4107
  • 1.4221
  • 1.6331
  • e**eeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.1085
  • 1.1578
  • 1.1299
  • 1.1053
  • 1.1106
  • 1.0581 *

.6255

  • e.1. 4724
  • 1.4078
  • 1.4399
  • 1.4552
  • 1.4174
  • 1.4007..*. 2. 5051..*

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.1149
  • 1.1267
  • 1.U839
  • 1.0860 *

.9757 *

.6405 *

  • 1 4571..*.1. 4369.*. 1 4936..*.1. 470.3.*eeee.6255
  • 2.4458
  • 1 e..

eeeeeeeeeeeeee.

15 *

.9757 *

.7636 *

.9007 *

.7626

. 1. 6 4 9 7.. *. 2. 1012.. *. 1. 7 810.. *. 2. 1015. *. M-SUB-Q AT 100% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 e BOTTOM)

H O

F E

D C

.B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.9082

  • 1.2991
  • 1.2766
  • 1.3966
  • 1.1674
  • 1.2777
  • 1.2713
  • 1.1203
  • e 1. 8 87 3..*.1 3 3 3 6.*.1 3 614.*.1. 2 377
  • 1. 4 63 5
  • 1. 3 47 6 * ~ 1. 3 4 8 6
  • 1. 5159
  • ee..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.2991
  • 1.1181
  • 1.3998
  • 1.3066
  • 1.4073
  • 1.3248
  • 1.2938 *

.8654 *

. 1 3336..*.1 5329 6 1. 2377..*. 1. 3275.*. 1. 2228.*.1. 2997..*. 1. 3216..*. 1. 9441..*

j 1

10

  • 1.2766
  • 1.4009
  • 1.335b
  • 1.4234
  • 1.3173
  • 1.3034
  • 1.2402
  • 1.0378
  • e.1. 3614..... 1. 2363..*. 1. 2980.*. 1. 2061
  • 1.3069
  • 1.3191
  • 1.3794
  • 1. 6328..*

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.3966
  • 1.3098
  • 1.4266
  • 1.1952
  • 1.4223
  • 1.2777
  • 1.2584 *

.8739

  • j

. 1. 2377

  • 1.3232
  • 1.2040
  • 1.4228
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.4.*. 1.3476
  • 1.9425
  • 1.2067
  • 1.338 eeeeeeeeeeeeeeee.

4 12

  • 1.1674
  • 1.4137
  • 1.3238
  • 1.4255
  • 1.3113
  • 1.3045
  • 1.1278 *
  • 1.4635
  • 1.2172
  • 1.3020
  • 1.2040
  • 1.2941
  • 1.2900
  • 1.5019
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.2777
  • 1.3302
  • 1.3098
  • 1.2820
  • 1.3088
  • 1.2424 *'.7165
  • e.1 3 47 6. *.1.2 9 4 9.. *. 1. 313 4..*. 1. 3 3 41.. *. 1. 2 9 3 3.*.
1. 3 5 81..*. 2. 3 2 9 5. *.

14

  • 1.2713
  • 1.2959
  • 1.2434
  • 1.2627
  • 1.1331 *

.7347

  • e.1 3 4 8 6. *. 1. 319 8. *.1.3 7 5 9. *.1.3 42. 6. *. 1. 4 9 4 5.. *.2.

2 714.

  • 15
  • 1.1203 *

.8654

  • 1.0399 *..8771
  • 1.5159
  • 1.9474
  • 1.6290
  • 1.93 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.53.*. M-SUB-Q e

v m

v n

_m m.

L Catawba 2 Cyde 7 Core Operating Limits Report Page 84 of 144 Appendix A TABLE 2 (CONTINUED)

POWER ESCALATION F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP MARGIN)

AT 100% POWER, 4 "FPD, THIS IS LEVEL 14 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

C

.8 A

....H......... O........ F......... E......... D...... e e e e e e e e e.

eeeeeeeeeeeeeeeeee 8*

.9735

  • 1.4041
  • 1.3730
  • 1.5048
  • 1.2456
  • 1.3698
  • 1.3537 *~1.1942
  • e.1. 8. 6 7 2.. *.1.

3114..*.1. 3 4 4 5.. *.1 2 2 0 5. *.1 4 4 9 3.. *.1 3 3 5 6. *.1.

3 4 4 8. *.1..~. 510 5.

  • 9
  • 1.4041
  • 1.1984
  • 1.5123
  • 1.4030
  • 1.5187
  • 1.4148
  • 1.3848 *

.9168 *

  • 1 3114..*.1. 5112..*.1. 2170..*.1 3143
  • 1.2089
  • 1.2937
  • 1.3119
  • 1.9420 *.

e..

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.3730
  • 1.5144
  • 1.4341
  • 1.5300
  • 1.4148
  • 1.4019
  • 1.3238
  • 1.1096 *

. 1. 3445

  • 1. 2156.*. 1. 2.844.*. 1. 1894.*.1. 2970.*.1 3038.*.1. 3758.*.1. 6260.*

11

  • 1.5048 *'1.4052 *-1.5412
  • 1.2820
  • 1.5358
  • 1.3709
  • 1.3516 *..9296
  • e.1. 2205
  • 1. 3104.*.1. 1874..*. 1. 4059.*.1. 1901.*. 1. 3300..*..1 3371.
  • 1. 9.451.*.

12

  • 1.2456
  • 1.5251
  • 1.4201'* 1.5401
  • 1.4159
  • 1.4084
  • 1.2001 *

' l

  • 1 4493 4'1. 3028.*..-1. 2914.*. 1. 1874.*..1 2875.*.1 2840.*. 1 4989.*

13

  • 1.3698
  • 1.4212
  • 1.4004
  • 1.3762
  • 1.4126
  • 1.3366 *..7626
  • e 1.3356.*. 1. 2883..*. 1. 2983..*..1. 3250.*.1 2814.* 1 3532..e. 2. 3 3 07.. *e ee 14
  • 1.3537
  • 1.3069
  • 1.3270
  • 1.3570
  • 1.2145 *.7818
  • e.1 3448.*.1. 3101..*..1. 3715.*..l1. 3321
  • 1.4906
  • 2.2736
  • eeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1942 *'.9157
  • 1.1117 *.932S
  • F-SUB-Q-
  • 1. 5105.*.1. 943.8.*. 1. 6224 *eeee.9365.* M-5DB-Q 1.....

. e AT 100% POWER,.

4 EFPD, THIS IS LEVEL 13 OF 10

(LJVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

....H.........O... e e e e e e e e e e e e e e e e e e e e e e e'e e e n...... C.........B......... A......

F E

D 8* 1.0560

  • 1.5305
  • 1.4994
  • 1.6397
  • 1.3548
  • 1.4090
  • 1.4737
  • 1.3013 *

. 1. 8255.*.1. 2817..*.1. 3122..*. 1. 1935.*.1. 4114.*. 1 3090.*.1. 3170..*. 1. 4772..*

9

  • 1.5305
  • 1.3055
  • 1.6515
  • 1.5294
  • 1.6560
  • 1.5412
  • 1.5090 *

.9939

  • i
  • 1. 2 817.. *. 1. 47 0 6. *. 1. 18 8 3
  • 1. 2 8 4 8.. *. 1. 1817..*. 1. 2 67 4.. *. e e e. 2 8 4 0
  • 1. 8 9 0 0
  • 1 eeeeeeeeeee.

eeeeeeeeeeeeee.

10

  • 1.4994
  • 1.6526
  • 1.5637
  • 1.6783
  • 1.5433
  • 1.5203
  • 1.4405
  • 1.2001 *
  • 1. 3122..*.1. 1869.*.1. 2570..*. 1. 1.651.*. 1. 2711..*. 1. 2772..*. 1. 3493..*. 1. 5943.*.

11

  • 1.6397
  • 1.5326
  • 1.6825
  • 1.3977
  • 1.6772'* 1.4962
  • 1.4769
  • 1.0089 *
  • 1. 19 3 5. *.1. 2 817.. *. 1. 16 2 6.. *. 1. 3718. *.1.

16 57.. *.1.3 0 5 9...*.1.

3114. *. 1. 9152.. *e e.

12

  • 1.3548
  • 1.6643
  • 1.5497
  • 1.6815
  • 1.5444
  • 1.5401
  • 1.3184 *

. 1. 4114. *.1. 17 6 6. *. 1. 2 6 51.. *. 1. 16 3 2.. *. 1. 2 6. 4 9.. *. 1. 2 612.. *. 1. 4 7 31. *. =

13

  • 1.4898
  • 1.5476
  • 1.5358
  • 1.5015
  • 1.5455
  • 1.4619 *

.8279

  • e.1. 3 0 9 0.. *. 1 2 6 2 2.. *. 1. 2711. e *e e e e. 3 0 0 3
  • 1. 2 5 6 8
  • 1. 3 2 8 2
  • 2 2 9 0 5
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeee een 14
  • 1.4737
  • 1.5123
  • 1.4440
  • 1.4833
  • 1.3259 *

.8493 *

  • 1. 3170..*. 1. 2817.* 1. 3459..*. 1. 3059.*.1. 4651.*..-2. 2325..*.

e.

15

  • 1.3013 *

.9939

  • 1.2102
  • 1.0132
  • F-8UB-Q-

. 1. 4772..*.1 8997..*.1 5908..*. 1. 9084.*. M-SUB-Q-i i

- 1

~ ~

,.- ~~

~

- - ~

1

(

Catawba 2 Cycle 7 Core Operat_ing Limits Report Page 85 of 144 Appendix A 1

l TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q M MARGIN)_-. POWER ESCALATION AT 100% POWER, 4 EFPD, THIS IJ LEVEL 12 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)'

k

.....................F.........E.........D........C.........B.........A.....

H Q

8* 1. 0 9 03

  • 1. 5 9 5 8 + 1. 5615
  • 1.7115
  • 1.4084
  • 1.5540
  • 1.5347
  • 1.3559
  • a
  • 1.8820
  • 1.3065 + 1 3396
  • 1.2156
  • 1.4478
  • 1.3355
  • 1.3455
  • 1.5085
  • j e eeeeeeeeeeeeeee....

.eeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeee j

9

  • 1.5958
  • 1.3559
  • 1.7243
  • 1.5926
  • 1.7307
  • 1.6044
  • 1.5744
  • 1.0314 *
  • 1.3065
  • 1.5075
  • 1.2088
  • 1.3121
  • 1.2021
  • 1.2948
  • 1.3089
  • 1.9613
  • 3 i

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 10

  • 1.5615
  • 1.7265
  • 1.6290
  • 2.7543
  • 1.6076
  • 1.5958
  • 1.4994
  • 1.2563 *
  • 1.3396
  • 1.2075
  • 1.2833
  • 1.1850
  • 1.2963
  • 1.3002
  • 1.3789
  • 1.6312 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

1 11

  • 1.7115
  • 1.5958
  • 1.7586
  • 1.d555
  • 1.7 522
  • 1.559 4
  • 1.5412
  • 1.0453
  • 24.*. 1. 4028.*. 1. 1857..*. 1. 3314.*. 1. 3355.*.1 9675..*.
  • 1.2156
  • 1.3081
  • 1.18 eeeeeeeeeeeeeeeeeeeeeee.

eeee.

10

  • 1. 637 9
  • 1. 8218
  • 1. 7 018
  • 1. 8 571
  • 1. 6 86 8
  • 1. 6911
  • 1. 5712
  • 1. b i9 8 *

. 1 3632..*. 1. 2183.*.1. 3089.*.1. 1994.*.1. 3225.*. 1. 3176..*.1. 4177..*. 1. 6510..*.

11

  • 1.8036
  • 1.6697
  • 1.8635
  • 1.5240
  • 1.8560
  • 1.6376
  • 1.6290
  • 1.0774
  • 1.3604
  • 1.3710
  • 2.0650 *

...... 1. 3330

  • 1.1961.*. 1 4617
  • 1.2008 *
  • 1 2280 *

....ee..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

e..

12

  • 1.4639
  • 1.8410
  • 1.6954
  • 1.8625
  • 1.6900
  • 1.7062
  • 1.4341
  • e.1. 5117.. *. 1, *. 2 07 5.. *. 1. 315 2
  • 1. 19 6 8. *. 1. 3 2 9 0. *. 1. 314 4. *.1. 5 618.
  • e e

..ee..

13

  • 1.6354
  • 1.6933
  • 1.6997
  • 1.6461
  • 1.7157
  • 1.6065 *

.8836 *

  • 1. 3539..*. 1. 3160.*. 1. 3105.*. 1. 3615
  • 1.3089
  • 1.3994
  • 2.5455 *

.e

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeet 14

  • 1.6183
  • 1.6708
  • 1.5776
  • 1.6376
  • 1.4437 *

.9071 *

  • 1. 3 719.. *. 1. 3 2 81.. *. 1. 413 0
  • 1. 3 6 41.. *e e e e. 5 517.. *. 2. 47 8 5.
  • 1 e.

.eeeeee..

ee.

15

  • 1.4266
  • 1.0678
  • 1.3141
  • 1. 0817
  • 2.0650
  • 1.6858
  • 2. 0552..*. M-8UB-Q 1..eeeeeeeee ** ee.

Catowba 2 Cycle 7 Core Operating Limits Report Page 87 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q G M SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 100% POWER, 4 BFPD, THIS IS LEVEL ' 8 'OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G...ee....F.........E.........D.........C.........B.........A......

8* 1.1235

  • 1.6954
  • 1.6600
  • 1.0410
  • 1.4908
  • 1.6708
  • 1.6579
  • 1.4630 *

. 1. 9204.*.1. 27.50.*.1 3081.*.1 1773..*.1. 4519...*.1. 297.9.*. 1. 3105.*. 1. 4732.*.

l

...... e.

l 9

  • 1.6954
  • 1.4234
  • 1.8582
  • 1.7007
  • 1.8732
  • 1.7243
  • 1.7093
  • 1.0924 *-

. e.1 2 7 5 0. *. 1 5191. *.1.16 8 4. *.1.2 7 9 5. *.1.16 0 9. *. 1. 2. 6 31. *.1 2. 6 9 8. *. 1 9 7 2 2..

  • i 10
  • 1.6600
  • 1.8603
  • 1.7372
  • 1.9000
  • 1.7265
  • 1.7318.* 1.6086
  • 1.3409 *
  • 1. 3081..*.1. 1671..*.1. 2536
  • 1. 1449.*. 1 2.638..*.1. 2587..*.1 3547..*.1. 6166..*

e.

11

  • 1.6410
  • 1.7061
  • 1.9064
  • 1.5572
  • 1.8989
  • 1.6772
  • 1.6708
  • 1.0988
  • e e e e e e e e e e e e e e e e e e e e e e. 419. e
  • e e e. 3 9 7 5. *.1 14 61. *.1.

3 0. 4 2.. *. 1. 3 0 4 9. *.1 9 7 8 3. *.

1 1.1773

  • 1.2765
  • 1.1..

e e.

12

  • 1.4908
  • 1.8828
  • 1.7361
  • 1.9053
  • 1.7297
  • 1.7532
  • 1.4683 *
  • 1. 4519.*.1.1547
  • 1.2572
  • 1.1425
  • 1.2660
  • 1 2471.*.1. 4878 l

... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

.. een j

13

  • 1.6700
  • 1.7329
  • 1.7404
  • 1.6847
  • 1.7607
  • 1.6483 *

.9007 *

. 1. 2979.*. 1. 2565.*. 1.2514

  • 1.2979.*. 1. 2414.*.1 3281..*.2. 4339.*

eeeeeeeeeee 14

  • 1.6579
  • 1.7125
  • 1.6151
  • 1.6793
  • 1.4791 *'.9253 *

-. 3 3105..*.1. 2675..*. 1 3.497..*.1. 2987..*. 1. 4776.*.2. 3674.*.

15

  • 1.4630
  • 1.0913
  • 1.3441
  • 1.1042
  • 1. 47 3 2.. *.1 97 4 0..*.1. 6118.*.1. 9 6 9 3. *e M-SUB-Q l

AT 100% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) i H

G F

E D

C B

A seeeeeeeeeeeeeeeeeeeeeeeeeeeeeee....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e j

8

  • 1.0988
  • 1.6718
  • 1.6376
  • 1.8218
  • 1.4694
  • 1.6536
  • 1.6429
  • 1.4501
  • l 1.9037
  • 1.2479
  • 1.28..eeeeee 1

i eeeeeeeeeeeeeeeeeeeeee. 18

  • 1.1494..*eee.4212
  • 1.2640
  • 1.2702
  • 1. 42.19..*.

e eeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6718
  • 1.3987
  • 1.8389
  • 1.6783
  • 1.8560
  • 1.7061
  • 1.6954
  • 1.0785 *
  • 1. 2 47 9. *.1. 4 914. *.1.14 4 3.. *. 1. 2 5 63.. *.1.

13 6 5. *. 1. 2 3 5 5.. *. 1 2 3 2 5. *. 1. 9112.. *e l

10

  • 1.6376
  • 1.8410
  • 1.7136
  • 1.8828
  • 1.7072
  • 1.7179
  • 1.5926
  • 1.3259
  • i
  • 1.2818
  • 1.1431
  • 1.2345
  • 1 1273..*. 1. 2.429.*. 1. 2305.*.1. 3221.*.1. 5649.*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeen 11

  • 1.8218
  • 1.6847
  • 1.8892
  • 1.5380
  • 1.8817
  • 1.6500
  • 1.656a
  • 1,na3B e
  • 1.1494
  • 1.2533
  • 1.1247
  • 1.3826
  • 1.1298
  • 1.2902
  • 1.2808
  • 1.9288
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 12
  • 1.4694
  • 1.8657
  • 1.7179
  • 1.8892
  • 1.7115
  • 1.7393
  • 1.4523 *

. 1. 4212..*e41.1306.*. 1. 2360.*.1. 1258.*. 1 25.50.*. 1. 2322..*.1. 4713..*.

13

  • 1.6536 '

7147

  • 1.7265
  • 1.6686
  • 1.7479
  • 1.6333
  • 88C8
  • e.1 2640.*._ 2292...*.1. 2235..*. 1 2841..*. 1 2.266.*.1. 3144... 2. 4124.*.

14

  • 1.6429
  • 1.6997
  • 1.5979
  • 1.6654
  • 1.4630 *..9125
  • e.1. 2 7 0 2.. *.1.

2 3 0 4. *. 1. 317 4. *. 1. 2 7 4 6

  • 1. 4 6 0 6. *. 2. 3 47 0.. *.

15

  • 1. 4 501
  • 1. 077 4
  • 1. 33 02
  • 1. 08 81
  • 1.4219
  • 1.9128
  • 1.5604
  • 1.9199
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeee....eeeeeeeeeee c.

e

4 Catawba 2 Cycle 7 Core Operating Limits Report Page 88 of 144 Appendix A I

TABLE 2 (CONTINUED) j F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION..

AT 100% POWER, 4 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

G F

D C

B A

e...H....... e e e e e e e e e e e e e e

  • e..B.. e e e e e e... s e e e e e e e e e e e e e e e e e e e e e.

eeeeeee B* 1.0410

  • 1.5979
  • 1.5626
  • 1.7479
  • 1.4019
  • 1.5883
  • 1.5776
  • 1.3934 *

. 1 9134.*.1. 2491.*. 1. 2865.*.1. 1464

  • 1.4258
  • 1.2574 *.1.2662-* 1.4165 *-

a eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.5979
  • 1.3302
  • 1.7639
  • 1.6044
  • 1.7832
  • 1.6343
  • 1.6311
  • 1.0303 *
  • 1. 2 4 91. *. 1 5 015. *.1 1419.. *.1.

2 5 8 2. *.1.1313.. *. 1. 2 3 2 7. *. 1. 2 2 5 9

  • 1. 9161.. *e i

.ee.

eeeeee.

10

  • 1.5626
  • 1.7661
  • 1.6365
  • 1.8089
  • 1.6365
  • 1.6526
  • 1.5262
  • 1.2702 *-
  • 1 1.2408
  • 1.2234
  • 1.3186
  • 1.5613.*

eee 2865

  • 1.1401
  • 1.2358
  • 1.1198
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

- 11

  • 1.7479
  • 1.6097
  • 1.8153
  • 1.4705
  • 1.8078
  • 1.5915
  • 1.5915
  • 1.0324
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.308.*

1.1214

  • 1.2826
  • 1.2703
  • 1.9..

e.1 1464 *..e 1.2544

  • 1,1164
  • 1.3790
  • 4 eeeeeeeeeee i

12

  • 1.4019
  • 1.7929
  • 1.6461
  • 1.8153
  • 1.6397
  • 1.6729
  • 1.3902
  • eeeeeeeeeeeeeeeeeeeeee.337..*.1 1174.*. 1. 2.552
  • 1.2256 *'1.4619
  • j
  • 1.4258
  • 1.1248
  • 1.2 ee.

.eeeeeeeeeeeeeeeeeeeen 13

  • 1.5883
  • 1.6440
  • 1.6611
  • 1.5990
  • 1.6815
  • 1.5658 *

.8450 *

')

j

  • 1. 2 57 4. e *e.1.

2 2 6 5. *. 1. 216 0

  • 1. 27 5 8. *. 1. 2 2 0 0.
  • e n 310 5. *. 2. 4 0 6 3..
  • 1 ee

.eeeeeeeee.

eee e e ee 1

14

  • 1.5776
  • 1.6343
  • 1.5315
  • 1.6011
  • 1.4009 *

.8697 *

  • t.40 l

,

  • e e. 6 2. *. 1. 22 3 3.. *.1. 313 8. *. 1. 2 6 3 6. *.14 512
  • 2.3 3 9 2
  • 5

......eeeeeeeeeeeeee i

15

  • 1.3934
  • 1.0292
  • 1.2745
  • 1.0389

. 1 4165.*.1. 9165..*. 1.5568

  • 1.9222..* M-SUB-Q

.eeeeeeeeeee j

.I l

AT 100% POWER, 4 EFPD,. THIS 18 LEVEL 5 OF 18 (LEVEL 18_= TOP OF CORE, LEVEL 1 = BOTTON) 1 H

G F

E D

'C-B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 1

8

  • 1.0067
  • 1.5519
  • 1.5219
  • 1.7061'* 1.3677
  • 1.5583
  • 1.5487
  • 1.3687 *

)

  • 1.8906
  • 1.2317
  • 1.2647
  • 1.1246
  • 1.3989
  • 1.2267
  • 1.2334
  • 1.3797
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.5519
  • 1.2916
  • 1.7200.* 1.5647
  • 1.7436
  • 1.6011
  • 1.6001
  • 1.0089 *
  • 1.2317
  • 1.4799
  • 1.1208
  • 1.2348
  • 1.1051
  • 1.2015
  • 1.1942
  • 1.8726
  • l 1

1 eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeee l

10

  • 1. 5219
  • 1. 7222
  • 1. 59 5 8
  • 1.7 6 81
  • 1. 6 011
  • 1. 6172
  • 1. 49 51 + 1. 2 4 4 5
  • e.1. 2 6 47..*. 1. 1191..*. 1. 212 0.. *.1.0 9 3 9..*. 1. 2.116
  • 1.1949
  • 1.2854
  • 1.5242
  • J eeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 1

11

  • 1.7061
  • 1.5712
  • 1.7757 a 1.4373
  • 1.7682
  • 1.5583
  • 1.5604
  • 1.0089
  • eeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeee 2487
  • 1.2352
  • 1.8916
  • e.1. 12.46
  • 1.2299
  • 1.0903
  • 1.3456
  • 1.0945
  • 1
    • eeeeeeeeeeeeeeeeeeeee.

12

  • 1.3677
  • 1.7554
  • 1.6108
  • 1.7757
  • 1.6054 *21.6408
  • 1.3612
  • i
    • ee.989.*. 1.0980
  • 1.2042
  • 1.0906
  • 1.2178
  • 1.1874
  • 1.4220 *
  • 1.3..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.5583
  • 1.6097
  • 1.6258
  • 1.5669
  • 1.6493
  • 1.5358 *

.8257 *

  • 1.2267
  • 1.1968
  • 1.1877
  • 1.2422
  • 1.1816
  • 1.2689
  • 2.3465
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.5487
  • 1.6044
  • 1.5015
  • 1.5701
  • 1.3720 *

.8493 *

  • 2.2808 *-

. 1 2334.*. 1. 1919.*.1. 2809..*. 1. 2289.*. 1.4113

.eeeeeeeeeeeeeeen 15

  • 1.3687
  • 1.0078
  • 1.2488
  • 1.0142
  • - 1. 3 7 9 7.. *. 1. 8 7 3 6. *. 1. 519 9. *.1 8 817.. *. M-SUB-Q ~

Catawba 2 Cycle 7 Core Operating Limits Report Page 89 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OF MARGIN) - POWER ESCALATION AT 100% POWER, 4 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

)

B A

e... H......... G......... F......... E...... e

  • D......... C....... e e....... e e e e e e e e 8*

.9082

  • 1.4126
  • 1.3827
  • 1.5637
  • 1.2499
  • 1.4394
  • 1.4287
  • 1.2627
  • eeeeeeeeeeeeeeeeeeeeeeeeeee
1. 1792
  • 1.4713
  • 1.2747..*.eee.2835
  • 1.4365 *
  • 2.0153
  • 1.3009
  • 1.3388
  • 1 eeeeeeeeeeeeeeeee eeeeeeeeeeeeee.

9

  • 1.4126
  • 1.1717
  • 1.5722
  • 1.4276
  • 1.6054
  • 1.4726
  • 1.4769 *-.92C4 *
  • 1. 3 0 0 9. *.1. 5 6 9 0.. *.1.

17 7 9. *.1.3 0 01.. *. 1. 1518.. *.1e. 2 5 3 3

  • 1. 2 414..*.1. e. 9 5 8 5
  • eeeeeen..

eeeeeeeee..

eeeee 10

  • 1.3827
  • 1.5744
  • 1.4544
  • 1.6236
  • 1.4662
  • 1.4887
  • 1.3741
  • 1.1417 *
  • 1.3388 4 1.1763
  • 1.2774
  • 1.1424
  • 1.2677
  • 1.2450
  • 1.3416
  • 1.5939
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11 + 1.5637

  • 1.4341
  • 1.6301
  • 1.3141 + 1.6236
  • 1.4298
  • 1.4351 *

.9211

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.17..*eee.1424
  • 1.3032
  • 1.2854
  • 1.9865 *
  • 1.1792
  • 1.2946
  • 1.1384
  • 1.41 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.2499
  • 1.6161
  • 1.4758
  • 1.6301
  • 1.4726
  • 1.5101
  • 1.2477 *

['

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 2..*.1. 2600

  • 1.2312
  • 1.4829 *
  • 1.4713
  • 1.1442
  • 1.2602
  • 1.138 eeeeeeeeeeeeeeeeeeeeee.

l 13

  • 1.4394
  • 1.4791
  • 1.4962
  • 1.4373
  • 1.51871.4105 *

.7551 *

  • 1. 27 47
  • 1 2 4 8 6.
  • e e. 2372
  • 1. 2 9 7 0
  • 1. 22 53
  • 1. 317 9
  • 2. 4 519
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeeeeeeee 14

  • 1.4287
  • 1.4812
  • 1.3794
  • 1.4437
  • 1.2584 *

'.7765

  • j 1.2835
  • 1.2393
  • 1.3366
  • 1.2782
  • 1.4718
  • 2.3830
  • l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2627 *

.9253

  • 1.1460 *

.9264

  • F-SUB-Q e.1 4 3 6 5. *.1 9. 6 0 3.. *. 1. 5 8 9 2.. *. 1. 9 7 6 6..
  • M-SUB-Q j

i l

AT 100% POWER, 4 EFPD, TH78 IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEV 8 1 = BOTTON) l e...H.........G........F.........B.... e e. e e e. e e e e e e e........ e e e e e e e... A......

D C

B r

l 8*

.8140

  • 1.2627
  • 1.2402
  • 1.4148
  • 1.1395
  • 1.3270
  • 1.3227
  • l'.1588
  • 0..*. 1. 5596.*. 1. 3359.*. 1. 3.40.1.*. 1. 5116
  • eeeeeeeeee.1. 4083..*. 1 4445
  • 1.260
  • 2.1782 *

...e

..eeeeeeee...

9

  • 1.2627
  • 1.0528
  • 1.4116
  • 1.2884
  • 1.4662
  • 1.3570
  • 1.3602 *

.8536

  • 2 3..*.1.218.1.*.1. 313 6.*. 1. 3 02 5..*. 2.e. 0 5 2 9 *
  • 1.4083
  • 1.6889
  • 1.2685
  • 1.39 eeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

10

  • 1.2402
  • 1.4137
  • 1.3088
  • 1.4694
  • 1.3366
  • 1.3580
  • 1.2627
  • tiO378 *
  • 1. 4445
  • 1. 2670..*. 1. 3724..*.1. 2181.*. 1. 3425.*. 1. 3160..*.1 410.5.*.1 6942..*.

...e**e 11

  • 1.4148
  • 1.2938
  • 1.4758
  • 1.1974
  • 1.4726
  • 1.3045 *'1,3098 *

.8354 *

  • 1.2600
  • 1 3865
  • 1. 2136 *ee..... 49491....*. 1.2174
  • 1. 3768
  • 1.3582
  • 2.1144 *
    • eeeeeeeeee eee....

.eeeeeeeeeeeeeeeeeeeeeen 12

  • 1.1395
  • 1.4758
  • 1.3452
  • 1.4769
  • 1.3430
  • 1.3773
  • 1.1395
  • e.1. 5596
  • 1. 2099..*. 1. 3351.*. 1 2126.*eee.3401
  • 1.3002
  • 1.5648 1

..e eeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.3270
  • 1.3623
  • 1.3666
  • 1.3109
  • 1.3837
  • 1.2906 *

.6919

  • e 1. 3359.*. 1. 3088.*ee. 3080..*. 1 3698 *..... 1. 2 9 4 0.. *.1.

3 8 7 4.. *.2.

57 87.. *.

1 14

  • 1.3227
  • 1.3634
  • 1.2681
  • 1.3173
  • 1.1492 *

.7122 *

  • 1.3401
  • 1.2997
  • 1.4054
  • 1.3506
  • 1.5529
  • 2.5037
  • eeeeeeeeeeeeeeeeeeeeeeeeeweeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 15

  • 1.1588 *

.8536 ' 1.0421 *

.8397

. 1.e.5116

  • 2.0540
  • 1.6889
  • 2.1042
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l I

I l-l

. ~

e m

e

i Catawba 2 Cyde 7 Core Operating Limits Report' Page 90 of 144.

)

Aqppendix A

~

TABLE 2'(CONTINUED)

F-SUB-Q ti M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - POWER ESCALATION

.AT 100% POWER, 4 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

..,O...........F.........E.........D.........C.........B......eee**.e.

A e...H......

8 *

.6522 *

.9842 *

.9746

  • 1.1235 *

.9382

  • 1.1171
  • 1.1256 *

.9478

  • e e e e e e e e e e.1. 7 631
  • 1.7 931
  • 1 5 4 5 5
  • 1. 8 4 42
  • 1. 5 43 3
  • 1. 5317
  • 1.7 9 82 *
  • 2.6545 *
    • eeeeeeeeeeeeeee... eeeeeeee.**eeeeeeeeeeeeeeeeeeeeeeeeeeeee 9*

.9842 *

.8386

  • 1.1031
  • 1.0228
  • 1.2038
  • 1.1438 8'1.1438 *

.7261 *

  • 1.763 l

e * *

  • e e.1. *. 2. 0. 6 0 6
  • 1. 5 817.. *. 1 710 0. *.1 4 4 2 8.. *. 1. 5157.. *.1.

5 0 51. *. 2. 3. 5 2 3. *.

['

......ee..

10 *

.9746

  • 1.1053
  • 1.0303
  • 1.1695
  • 1.0946
  • 1.1181
  • 1.0581 *

.8290 *'

  • 1.7931
  • 1.5794
  • 1.6993.* 1.4900
  • 1.5951
  • 1.5477.* 1.6362
  • 2.0666
  • eeeeeeeeeeeeeeeeeeeeeeeeeee...e.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.1235
  • 1.0271
  • 1.1738 *

.9768

  • 1.1984
  • 1.0753
  • 1.0710 *

.6769 *

. 1. 5 4 5 5.. *.1.7 019. *. 1. 4 8 4 9

  • 1.7 8 5 5
  • 1. 4 5 3 5
  • 1. 6 2 2 0.
  • e e e. 612 4
  • 2. 5 4 4 9
  • 1 eeeeeeeeeeeeeee.

....eeeeeeeeeeeeeeeeeeeeeeeeeee 12 *

.9382

  • 1.2124
  • 1.1010
  • 1.2038
  • 1.0946 *.1.1267 *

.9393

  • l eeee.442..*.1. 4337..*. 1. 5857.e*eee.4467
  • 1.5974
  • 1.5400
  • 1.8451 *
  • 1.8 1

.. e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13

  • 1.1171
  • 1.1481
  • 1.1235
  • 1.0006
  • 1.1331
  • 1.0592 *

.5826 *~

  • 1. 5433..*.1. 5104.*.1. 5400..*.1. 6136.*. 1. 5313..**1.6412...*.2. 9760 *

.ee e

      • ee eeeeee 6

14 a 1.1256 + 1.1460

  • 1.0624 *=1.0774 *

.9468 *

.5998'*

i

  • 1. 5317..*. 1. 5020.*. 1 6300..*. 1. 6040
  • 1.8310
  • 2.8925
  • eeeeeeeeeeeeeeeeeeeeeeen r

.7251-*

.8311 *,.6801

,,47, e

  • 1. 7 9 8 2. *. 2. 3. 5 3 3.*.2.0 5 9 6. *. 2.e. 5 313..
  • M-SUB-Q -

s.

e.e AT 100% POWER, 4 EFPD, THIS Is LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H G

E D

C B'

A eeeeeeeeeeeeeeeeeeee..F......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee B*

.4177 *

.3192 *..5880 *

.3802 *

.6051 *

.7593 *

.7058 *

.5451 *

  • ee 0651..*.5 3146.*. 2. 9058.*..4.4635
  • 2.7986
  • 2.2181
  • 2.3938
  • 3.0644 *
  • 4

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9' *

.3192 *

.5237 *

.3695 *

.6340 *

.4316 *-.7047 *

.7368 *

.4562

  • l
  • 5. 3146.*.3.2538 *
  • e e.. e e. e e 6115.* e e e. 6 9 3 7..*. 3. 9 312..*. 2. 4 0 9 8..*.2.

2 8 2 5. *. 3. 677. 6.*.

l 4.... e 2

e l

10 *

.5880 *

.3695 *

.6158 *

.3973 *

.6662 *

.7454 *

.6512 *-.2624

  • i
  • 2.9058
  • 4.6115
  • 2.7786
  • 4.28 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.69..*. 2.e.5522
  • 2.2682..*e.2.5999
  • 6.3923
  • i eeeeeeeee.. e eeeeeeeeeeeeeeeee 11 *

.3802 *

.6372 *

.3995 *

.6340 *

.4305 *

.6662 *

.6458 *

.4155 *

  • 4.4635
  • 2.6803
  • 4.2700
  • 2.6922
  • 3.9496
  • 2.5613 a 2.6156
  • 4.0651
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 12 *

.6051 *

.4348 *

.6704 *

.4327 *

.6640 *

.6908 *

.5591 *

  • 2.7986
  • 3.9029
  • 2 5373
  • 3.9353***eee.5734
  • 2.4579..*. 3 0368 2

t eeeeeeeeeeeeeeeeee...

.eeeeeeeee.

eeeeeeeeeeee

...e

'.6940 *

.6233 *

.3620

  • 13 *

.7593 *

.7069 *

.7486 *

.6694 *

  • 2.2181
  • 2.4018
  • 2.2587
  • 2.5492
  • 2.4468
  • 2.7315
  • 4.7074
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenee

(

14 *

.7058 *

.7379 *

.6533 *

.6501 *

.5633 *

.3716 *

  • * * *
  • e e... 2. 2 8 01. *. 2. 5 9 0 6. *.2.

6 03 0.

  • e * *. 013 2..
  • 4 5 8 2 2.. *.
  • 2.3938
  • 3 ee 15 *

.5451 *

.4562 *

.2635 *

.4177

  • 3. 0644.*.3. 6776. *see.3735
  • 4.0455
  • M-SUB-Q 6

e.

eeeeeeeeeeeeee.

i l

l

?

h u

i i

I

f Catawba 2 Cycle 7 Core Operating Limits Report Page 91 of 144 Appendix A TABLE 2 (CONTINUND)

F-SUB-Q & M-3UB-Q VALUES (F-SUB-Q OP MARGIN).* POWER ESCALATION.

AT 75% POWER, 4 EFPD, THIS Is LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 s BOTTON)*

j H

O F

E D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.3631 *

.2945 *

.5837 *

.3641 *

.5965 *

.7015 *

.6597 *'.5119 *

  • 3.3340
  • 4.7064
  • 2.5286
  • 4.0457
  • 2.4692
  • 2.0892
  • 2.2262
  • 2.8429
  • 9 2945
  • 5216 3513
  • 6212
  • 4006
  • 6640
  • 6747 4477 *
  • 4.7064
  • 2.7865
  • 4.1659
  • 2.3427
  • 3.6272
  • 2.2098
  • 2.1577
  • 3.2516
  • j eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10 *

.5837 *

.3513 *

.5998 *

.3674 *

.6362 *

.6747 *

.6158 *

.2517 *

  • 2.5286
  • 4.1577
  • 2.4

'y eeeeeeeeeeeeeeeeeeeeeee.016.*. 3. 9031..*.2.2744

  • 2.1229
  • 2.3453
  • 5.7013 *

... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

.3620 *

.5944 *-.5719 *

.4102

  • 11 *

.3641 *

.6244 *

.3695 *

.5698 * '

  • 4 0.457..*. 2. 3349..*. 3. 8887
  • 2.3532
  • 3.6147
  • 2.2573
  • 2.4071
  • 3.4432
  • e..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

12 *

.5965 *

.4027 *

.6383 *

.3631 *

.5119 *

.5205 *

.4862

  • l.
  • 2.4692
  • 3. 6085..*. 2. 2646
  • 3.6024
  • 2.2168
  • 2.2597
  • 2.6800
  • eeeeeeeeee.

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen j

j 13 *

.7015 *

.6651 *

.6769 *

.5965 *

.5237 *

.4530 *.3202

  • l
  • 2.0892
  • 2.2052
  • 2.1165
  • 2.2500
  • 2.2524
  • 2.4491
  • 3.9031
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14 *

.6597 *

.6758 *

.6180 *.5741 *

.4894 *

.3267

  • e.2. 2262.*.2 1577..*.2.e.3401
  • 2.3988
  • 2.6698
  • 3.8250
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15 *

.5119 *

.4477 *

.2517 *

.4113

  • 2.8429
  • 3. 2516.*. 5 6859
  • 3. 4319..* M-SUB-Q eeeeee eee.

..** ee.

AT 75% POWER, 4 BFPD,..THIS IS LEVEL 17 OF - 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H O

F E

D C'

-B A-r eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.5376 *

.8686 *

.8900 *

.9950 *

.8697 *

.9725 *

.9950 *

.8386

  • eeeeeeeeeeeeeeeeeeeeeeeeeeee.1. 8719..*. 2. 1360
  • 1.8996
  • 1.8571
  • 2.1831 *
  • 2.8986
  • 2.0909
  • 2.0960
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee p

9*

.8686 *

.7786 *-.9703 *

.9296

  • 1.0357
  • 1.0100 *

.9864 *~.6769 *

  • 2. 09 0 9. *. 2. 3 5 4 9.*.1. 912 3.' *. 1. 9 9 8 4
  • 1.7 67 8
  • 1. 819 0
  • 1. 8 5 9 8.*e e e e.7 0 9 4
  • 2 i

e.

eeeeeeeeeeeeeeeeeeee.**eeee..

eeeese 10 *

.8900 *

.9725 *

.9339 *

.9928 *

.9639 *

.9575 ' '.9425 *

.7486

  • ee**eeeeeeeeeeeeeeeeeeeee... 1. 8152..*e. 8884
  • 1.9109
  • 1.9324
  • 2.4168 *
  • 2.0960
  • 1.9094
  • 1.9754
  • 1.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen e

11 *

.9950 *

.9328 *

.9971 *

.8397 *

.9853 *

.9157 *

.8986 *

.6330 *

1. 7751.*.1. 9052..*.1. 0440 *...... 2. 8316...*
  • 1.8719
  • 1.9907
  • 1.8126
  • 2.0892
  • l eseeeeeeeeeeeeeeeeeeeeeeeeeeeeee......

12 *

.8697

  • 1.0399 *

.9693 *

.9885 *

.7626 *

.8418 *

.7904 *

. 2. 13 6 0.*. 1. 7 6 0 5.. *. 1. 8 815.. *.1.e.7 6 9 0. *. 1. 8 5 4 4.*.

1. 87 47..*.2. 13 6 0.*..

13 *

.9725

  • 1.0132 *.9618 *

.9189 *

.8461 *

.7733 *

.5044 *

  • 1. 8996.*.1. 8139..*. 1. 9024.*.1. 8982
  • 1.8692
  • 1.9302
  • 3.2417
  • e.

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14 *

.9950 *

.9885 *

.9446 *

.9029 *

.7947 *

.5162

  • 1 e.1. 8 571..
  • e e e. 8 571
  • 1 9 2 8 0..
  • e e e. 9 3 67..*. 2. 12 5 4.*.
3. 16 5 9.
  • 1 1

)

e eeeeeeee e..

e 15 *

.8386 *

.6758 *

.7497 *

.6351

  • 2.1831
  • 2.7122
  • 2.4123
  • 2.8192
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

I I

=- - -

Catawba 2 Cycle 7 Core Operating Limits Report Page 92 0f 144 Appendix A l

TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - POWER ESCALATION AT 75% POWER, 4 BFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF. CORE, LEVEL 1 = BOTTOM) a e.ee..................F......eeee........D.........C.........B.........A......

H G

E 8*

.7647

  • 1.1652
  • 1.1717
  • 1.2927
  • 1.0913
  • 1.1963
  • 1.2092
  • 1.0496
  • 2.5062
  • 1.7521
  • 1.7668
  • 1.5953
  • 1.8775
  • 1.7096
  • 1.6896
  • 1.9269 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.1652
  • 1.0164
  • 1.2852
  • 1.2113 *-1.3098
  • 1'.2477
  • 1.2199 *

.8150

  • e.1. 7 521. *.2. 0 0 57.. *. 1. 6 0 3 7.. *.1.

7 021. *.1. 5 537.. *.1.6 371.. *.1 6 6 6 0. *. 2. 47 67..

  • 10
  • 1.1717
  • 1.2863
  • 1.2306
  • 1.2991
  • 1.2242
  • 1.2145
  • 1.1652 *

.9585 *'

  • 3.7668.*. 1. 6018.*.1 6690.*. 1. 5476.*. 1. 6559
  • 1. 6751.*.1. 7366.*.2. 0961.*

eeeeee.

ee..

11

  • 1.2927
  • 1.2156
  • 1.3045
  • 1.0892
  • 1.2906
  • 1.1727
  • 1.1535 *

.8011 *

. 1. 5953..*.1 6958.*.1. 5450..*. 1. 8212..*.1. 5406..*.1. 688b

  • 1.7074
  • 2 4921.*

s

..eeeeeeeeeeeee.

.12

  • 1.0913
  • 1.3173
  • 1.2306
  • 1.2938
  • 1.1299
  • 1.1438
  • 1.0174 *
  • 1.8775
  • 1.5467
  • 1.6489
  • 1.5398
  • 1.6294
  • 1.6401
  • 1.9041
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.1963
  • 1.2531
  • 1.2209
  • 1.1770
  • 1.1481
  • 1.0774 *

.6372

  • e.1.7 0 9 6..*. 1. 63 03..
  • e e e. 6 67 0
  • 1. 6 8 3 3
  • 1. 63 42
  • 1.716 0
  • 2. 9 72 6
  • 1

. e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2092
  • 1.2220
  • 1.1685
  • 1.1588
  • 1.0239 *

.6533 *

  • 1.6896
  • 1.6629
  • 1.7322
  • 1.7011
  • 1.8936
  • 2.8969
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.**eeeeeeeeeeeeeeee l

15

  • 1.0496 *

.8140 *

.9607 *. 8 0 43

e.1. 9269.*. 2. 4790..*.2. 0913.*. 2. 4831

  • M-SUB-Q

..eene I

AT 75% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

~

... H.........G......e*F.......E.........D........C.........Be e e e e e... A.

  • e 8*

.9425

  • 1.3837
  • 1.3762
  • 1.5000
  • 1.2541
  • 1.3773
  • 1.3752
  • 1.2017 *
  • 2. 2947..*. 1. 5852..*.1. 6034
  • 1.4544
  • 1.7289
  • 1.5852
  • 1.5798
  • 1.7922
  • e.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.3837
  • 1.1899
  • 1.5144
  • 1.4126
  • 1.5330
  • 1.4330
  • 1.3998 *

.9200 *

. 1. 5852..*. 1. 8251.*.1. 4506

  • 1.5551
  • 1.4297
  • 1.5203
  • 1.5456
  • 2.3198 *

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.3762
  • 1.5155
  • 1.4426
  • 1.5347
  • 1.4244
  • 1.4094
  • 1.3366
  • 1.1053 *
  • 1.6034
  • 1.4491 1.5211
  • 1.4116
  • 1.5269
  • 1.5396
  • 1.6174
  • 1.9408
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 11
  • 1.5080
  • 1.4180
  • 1.5347
  • 1.2788
  • 1.5283
  • 1.3720
  • 1.3495 *..9221 *
  • 1.4544
  • 1.5499
  • 1.4088
  • 1.6723
  • 1.4116
  • 1.5620
  • 1.5762
  • 2.3229
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

12

  • 1.2541
  • 1.5305
  • 1.43J9
  • 1.5326
  • 1.4062
  • 1.3923
  • 1.1952 *
  • 1.7289
  • 1.4224
  • 1.5203
  • 1.4080
  • 1.5087
  • 1.5112
  • 1.7706
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.3773
  • 1.4394
  • 1.4169
  • 1.3784
  • 1.3977
  • 1.3152 *

.7433 *

. 1 5852.*.1. 5137..*.1 5337..*.1. 5568..*.eee.5055

  • 1.5906
  • 2.7922
  • 1 eeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.3752
  • 1.4030
  • 1.3409
  • 1.3559
  • 1.2027 *

.7626'*

  • 1.5798.*. 1. 5430..*.1. 6127..*.1. 5700
  • 1.7605
  • 2.7205 *
      • e.

.eeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2017 *

.9189

  • 1.1074 *

'.9264

  • F-SUB-Q-2 e.1 7 9 2 2.. *.2.3 217 e *.1.9 3 5 5. e
  • e e e. 313 2.. *. M-8UB-Q e

e e

1 1

i Catawba 2 Cycle 7 Core Operating Limits Report Page 93 of 144 J

Appendix A '

'l o

TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 75% POWER, 4 BFPD, THIS IS LEVEL 14 OF 18

.(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) f

....H........G........F.........E.........D.........C.........B.........A......

e 8

  • 1.0110
  • 1.4940
  • 1.4750
  • 1.6183
  • 1.3323
  • 1.4694
  • 1.4555
  • 1.2723
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeee.1 8176.*.
  • 1.5959
  • 1.6004
  • j
  • 2. 3032..*. 1. 5825.*.1. 6059..*. 1. 4546
  • 1.7396 9
  • 1.4940
  • 1.2723
  • 1.6322
  • 1.5133
  • 1.6386 *'1.5240
  • 1.4908 *

.9682 *

    • ee.825..*. 1. 8277..*.ee 4457..*. 1. 5624.*eee.4340
  • 1.5361..*. 1.5590
  • 2.3559 *~

1 1..

  • 1.5 2

.. e eeeeeeeen ee eee.e.eeeeeeeeee.

10

  • 1.4750
  • 1.6333
  • 1.5465
  • 1.6558
  • 1.5251
  • 1.5112
  • 1.4201
  • 1.1738
  • j

. 1 6059.*.1. 4442.*.1 5270

  • 1 4125.*.1 5378..*.1. 5453..*.1. 6394.*.'1. 9669.*

j 11

  • 1.6183
  • 1.5165
  • 1.6579
  • 1.3720
  • 1.6515
  • 1.4748
  • 1.4491 *

.9778

  • j

. 1. 4546.*.1. 5564.*. 1. 4090.*.1. 6777..*. 1. 4132'* 1.5772..*. 1.5896.*.2. 3.652..*.

eeeeeeeeee

.ee.

l:

12

  • 1.3323
  • 1.6472
  • 1.5326
  • 1.6568
  • 1.5200
  • 1.5123
  • 1.2831 *
  • 1. 7 3 9 6..*. 1. 4 2 6 0..*. 1. 5 311.. *. 1. 4 0 9 0..*. 1. 52 3 7.. *. 1. 52 0 4..*. 1. 7 9 6 8..*.

j 13

  • 1.4694
  • 1.5315
  • 1.5187
  • 1.4801
  • 1.5176
  • 1.4255 *

.7947

  • 4
  • 1. 5959.*. 1. 5286.*.1. 5386.*. 1. 5702.*.1 5147. *.1 6105..*.2. 8396.*

4 14

  • 1.4555
  • 1.4940
  • 1.4255
  • 1.4555
  • 1.2906 *

.8161

  • i
  • 1. 6004.*. 1. 5555..*.1. 6337..*. 1. 5825.*. 1. 7855.*. 2. 7634..*

J 15

  • 1.27J3 *

.9671

  • 1.1770 *

.9821

e.1. 017 6.. *e.2. 3 57 9 *eeeeeeee.1. 9614.*. 2. 3534.* M-SUB-Q 3

4 AT 75% POWER, 4 NFPD,. THIS IS LEVEL 13 OF 18 2

(LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

I

~

e...H.........G.........F..e.....E.........D.........C.........B..........A......

8

  • 1.0903
  • 1.6183
  • 1.6001
  • 1.7511
  • 1.4373
  • 1.5862
  • 1.5712 ' 1.3730 *
  • 2. 3021.*.1. 5826.*.1. 6056.*. 1. 4.564.*.1. 7362..*.1. 6020.*.1. 6074.*.1 82.42..*.

~

9

  • 1.6183
  • 1.3762
  • 1.7693
  • 1.6386
  • 1.7768
  • 1.6483
  • 1.6119
  • 1.0410 *
  • 1. 5826.*. 1. 8208.* 1 4454.*. 1. 5636.*. 1...4338.*.1. 5417..*.1. 5636..*. 2. 3583..*.

.j 10

  • 1.6001
  • 1.7714
  • 1.6750
  • 1.7961
  • 1.6536
  • 1.6365
  • 1.5347
  • 1.2659
  • j
  • 1. 6056..*. 1. 4432..*. 1. 5286..*. 1. 4140.*. 1. 5409..*. 1. 5476..*.1. 6471..*. 1. 9750.*.

11

  • 1.7511
  • 1.6429
  • 1.8004
  • 1.4876
  • 1.7939
  • 1.6001
  • 1.5744 *~1.0539
  • 4;
  • 1 4564.*.1. 5577.*.1.4099..*.1. 6730
  • 1. 4140.*.1. 5817.
  • 1 5931.*.2. 3818
  • 12
  • 1.4373
  • 1.7864
  • 1.6622
  • 1.6004 8 1.6536
  • 1.6483
  • 1.3923 *

. 1. 7 3 6 2.. *.1.4 2 67.. *. 1. 5 3 3 5

  • 1. 4 0 9 9.. *. 1. 5 2 9 4. *. 1. 52 21.. *. 1. 8 0 47..*e eeeeeeee 13
  • 1.5862
  • 1.6558
  • 1.6451
  • 1.6076
  • 1.6547
  • 1.5540 *

.8600

  • e.1 6020.*. 1. 5335..*. 1. 5409.*.1. 5748.*.1 5165.*. 1. 6147..*.2. 8467..*

e 14

  • 1.5712
  • 1.6161
  • 1.5401
  • 1.5819
  • 1.4019 *

.8836 *

  • 1. 6074.*. 1. 5602..*. 1. 6415.*. 1. 5861.*. 1 7934.*. 2. 7708..*.

e.

15

  • 1.3730
  • 1.0399
  • 1.2702
  • 1.0581
  • 1.8242
  • 2.36 eeeeeeeeeeeeen.03
  • 1.9709
  • 2.3719..*. M-SUB-Q eeeeeeeeeeeeeeeee i

l l

I i

I

)

__l 1

Catawba 2 Cycle 7 Core Operating Limits Report Page 94 of M4 Appendix A i

1 TABLE 2 (CONTINUED)

F-8UB-Q & M-SUB-Q VLLUES (F-SUB-Q CP KARGIN)

POWER BBCALATION AT

'#5% POWER,

.4 EFPD, THIS IS LEVEL 12 OF.18 (LB78L 18 = TOP OF CORE, LEVEL 1 = BOTTON)

H-0 F

E

.D

. C B

A eeeeeee............eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8* 1.1160

  • 1.6675
  • 1.6472
  • 1.8068
  • 1.4758
  • 1.6343
  • 1.6172
  • 1.4126 *

.eeeeeeeeeeeeeeeeeeeeeeee9.3 41.6542

  • 1.6812
  • 1.523.. 1. 8269.*. 1. 678.2.*.1 6861..*. 1. 9064..*

e 2.4234

  • ee.

9

  • 1.6675
  • 1.4126
  • 1.8282
  • 1.6879
  • 1.8368
  • 1.6965
  • 1.6622
  • 1.0667 *
  • 1.6542
  • 1.9135
  • 1.5106
  • 1.6392
  • 1.4996
  • 1.6190
  • 1. 6373
  • 2. 4808..*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

.. eee.

10

  • 1.6472
  • 1.8303
  • 1.7254
  • 1.8571
  • 1.7050
  • 1.6900
  • 1.5787
  • 1.3013 *
  • 1.6812
  • 1.5082 a 1.6037
  • 1.4804
  • 1.6181
  • 1.6217
  • 1.7305
  • 2.0734
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

11

  • 1.8068
  • 1.6922
  • 1.8625
  • 1.5315
  • 1.8550
  • 1.6504
  • 1.6247
  • 1.0796
  • j ene*ee.3.*. 1 6346.*eeee.4759
  • 1.7610
  • 1.4812
  • 1.6628
  • 1.6724
  • 2.5094
  • 1 1.523 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 12
  • 1.4758
  • 1.8464
  • 1.7136
  • 1.8614 *.1.7061
  • 1.7061
  • 1.4341
  • e.1 82.C.9.*.1. 4919..*.1 6100.*.1 4766
  • 1.6100
  • 1.5984
  • 1.9002 *

.......... eeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13

  • l'6343
  • 1.7050
  • 1.6997
  • 1.6579
  • 1.7136
  • 1.6044 *=.8836 *
  • 1.6782
  • 1.6109
  • 1.6145
  • 1.6552
  • 1.5913.*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1.6990
  • 14
  • 1.6172
  • 1.6665
  • 1.5840
  • 1.6322
  • 1.4437 *

.9082 *

  • 1. 6861.*. 1. 6346 *.ee.1. 7254..*.1. 6647
  • 1.8878
  • 2.9307
  • e.

eeeeeeeeeeeeeeeeeeeeee.

15

  • 1.4126
  • 1.0656
  • 1.3055
  • 1.0849
  • 1.9064
  • 2.4830
  • 2.0675
  • 2.4985
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee r

AT 75% POWER, 4 EFPD, THIS Z8 LEVEL 11 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTON)

D C

B A

....H.........G.........F.........E........ e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.

I 8

  • 1.1160
  • 1.6783
  • 1.6536
  • 1.8207
  • 1.4801
  • 1.6461-* 1.6268
  • 1.4223 *

. 2. 5 8 8 2.. *.1.7 42 0.. *. 1. 77 7 4. *. 1. 6 0 5 5. *.1 9 4 9 5. *.1 7 67 6. *. 1. 7 7. 6 3. *.2. e. 0 0 3 0

  • eeeee.

9

  • 1.6783
  • 1.4159
  • 1.8432
  • 1.6954
  • 1.8528
  • 1.7061
  • 1.6761
  • 1.0699 *
  • 1 7420.*. 2. 0431..*. 1. 5922..*.1. 7357
  • 1.5817
  • 1.7141
  • 1.7264
  • 2. 6384.*
    • e

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6536
  • 1.8453
  • 1.7329
  • 1.8742
  • 1.7136
  • 1.7061
  • 1.5851
  • 1.3077 *-

. 1. 7774.*. 1. 5905.*.1. 6990.*. 1. 562.9.*. 1 7151.*.1. 7131..*. 1. 8327..*. 2. 1897..*.

11

  • 1.8207
  • 1.6997
  • 1.8807
  • 1.5412
  • 118732
  • 1.6600
  • 1.6376
  • 1.0806 *
  • 1 6055
  • 2.7305
  • 1. 5587..*. 1. 8839.*. 1. 5638..*.1 7644
  • 1.7698
  • 2. 6644
  • e..

esseeeeeeeeeeee.

    • .eeee..

l'7157

  • 1.7232
  • 1.4416
  • 12
  • 1.4601
  • 1.8636
  • 1.7232
  • 1.8796 e.1. 9 49 5.*. 1. 5731.*. 1. 7 0 60.*. 1. 5 587
  • 1.7111
  • 1. 6 9 3 0
  • 2. 018 4 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.6461
  • 1.7147
  • 1.7147
  • 1.6686
  • 1.7307
  • 1.6172 *

.8857 *

  • 1. 7 6 7 6.*.1. 7 0 5 0..*. 1. 7 0 4 0..*. e e e.7 5 6 9
  • 1. 6 8 61
  • 1 8 0 5 2..*. 3. 2 3 37
  • 1 e.

eeeeeeeeeeeeeeeee

.eee.

14

  • 1.6268
  • 1.6793
  • 1.5915
  • 1.6461
  • 1.4523 *-.9104
  • l

. 1. 7 7 6 3...*.1.

7 2 2 3.. *. 1. 8 2 6 9. *. 1. 7 611.. *. e e e. 0 0 4 3

  • 3.14 81
  • 2 eeeeeeeeeeeeeee 15
  • 1. 42 2 3
  • 1. 0 6 8 9
  • 1. 312 0
  • 1. 0 8 6 0
  • 2. 0030..*. 2. 6409.*. 2. 1831.*.2. 6522..* M-SUB-Q e.

I I

1

.I l

u 1

t 1

~

l Catawba 2 Cycle 7 Core Operating Limits Report Page 95 of 144 Appendix A TABLE 2 (CONTINUED) 1 F-SUB-Q & M-SUB-Q VALUES (F+SUB-Q OP KARGIN) - POWER ESCALATION i

AT 75% POWER, 4 BFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........O.........F.........E..........D.........C.........B.........A eeeee.

1.1310

  • 1.7093
  • 1.6847
  • 1.8582
  • 1.5069
  • 1.6793
  • 1.6633
  • 1.4544
  • 8 *
  • 2.6315
  • 1.7483
  • 1.7818
  • 1.6109
  • 1.9741
  • 1.7007
  • 1.8007
  • 2.0369 *
  • eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.7093
  • 1.4405
  • 1.8807
  • 1.7286
  • 1.8925_* 1.7404
  • 1.7136
  • 1.0903 *

. 1. 7483..*. 2. 0663 ***1. 5957..*. 1. 7410.*. 1. 5878..*. 1 7295.*.1. 7483.*. 2. 7186.*

10

  • 1.6847
  • 1.8839
  • 1.7661
  • 1.9149
  • 1.7489
  • 1.7436
  • 1.6183
  • 1.3355 *
  • 1. 7 818. *.1. 5 9 4 0. *.1 7 0 5 0.
  • e. 571. 4. *.1. 7 2 3 3...*.1 7 2 6 4. *. 1 8 6 3 4
  • 2. 2 47 7
  • 1 e.

........ e

..ee.

. eeeeeeeeeeeeeee 11

  • 1.8582
  • 1.7329
  • 1.9214
  • 1.5722
  • 1.9139
  • 1.6943
  • 1.6740
  • 1.0999
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.. 1. 5740
  • 1.7884
  • 1.8052
  • 2.7455 *-
  • 1.6109
  • 1.7368
  • 1.5672
  • 1.9073 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeee 12

  • 1.5069
  • 1.9032
  • 1.7586
  • 1.9203
  • 1.7511
  • 1.7629
  • 1.4726 *
  • 1.9741.*.1. 5791
  • 1.7141
  • 1.5600..*.1. 7347..*. 1. 7213..*. 2. 0616.*
      • ee

.eeeeeeee

. eeeeee.

13

  • 1.6793
  • 1.7500
  • 1.7522
  • 1.7029
  • 1.7704
  • 1.6536 *

.9018

  • e.1. 7 0 07.. *.1.7 2 0 2
  • 1. 7161
  • 1. 7 7 9 6
  • 1. 7131
  • 1. 8 4 0 8
  • 3. 3 7 5 9 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.6633.* 1.7168
  • 1.6247
  • 1.6836
  • 1.4833 *

.9264 *

  • 1.8007
  • 1.7441
  • 1.8562
  • 1.7951
  • 2.0470
  • 3.2796
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 15
  • 1.4544
  • 1.0892
  • 1.3398
  • 1.1053

. 2. 0369.... 2. 7211..*. 2. 2407..*. 2 7299

  • M-SUB-Q eees AT 75% POWER, 4 EFPD, TRIS IS LEVEL 9 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

C B

A e...H.........O-.........F........ 2........D......eeeeeeeeeeeeeeeeeeeeeeeeeen 8* 1.0935

  • 1.6665
  • 1.6376
  • 1.8153
  • 1.4630
  • 1.6408
  • 1.6226
  • 1.4201
  • e.2. 6669.*.1. 7526 *e e. 1. 7 9 0 6
  • 1. 6 07 3
  • 1. 9 8 9 2.. *. 1. 7 7 41
  • 1. 7 8 51
  • 2. 0141
  • eeeeeeeeeeeeee...

eeeeeeeeeeeeeeeeeeese 9

  • 1.6665
  • 1.3955
  • 1.8378
  • 1.6804
  • 1.8507.* 1.6954
  • 1.6761
  • 1.0592 *
  • 1.7526
  • 2.0914
  • 1.5966
  • 1.7494
  • 1.5870
  • 1.7347
  • 1.7410
  • 2.7044
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 10
  • 1.6376
  • 1.8400
  • 1.7168
  • 1.8732
  • 1.7018
  • 1.7061
  • 1.5765
  • 1.3013
  • e.1. 7906.... 1.5948..*. 1. 7141.*. 1. 5706
  • 1. 7305
  • 1.7254
  • 1.8682
  • 2.2494
  • e**.e eeeeeee..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.8153.* 1.6858
  • 1.8796
  • 1.5305
  • 1.8721
  • 1.6504
  • 1.6354
  • 1.0678 *
  • 1 1.8052
  • 2.7612
  • e.1. 6073..*. 1. 7452.*. 1.565G
  • 1 9229-*... 1.5723....... 7940
  • eeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.4630
  • 1.8614
  • 1.7115
  • 1.8796
  • 1.7050
  • 1.7243
  • 1.4341
  • e.1. 9 8 9 2.. *. 1. 57 8 3.. *. 1. 7 2 02.. *. 1. 5 6 6 3.. *. 1. 7 410.. *. 1. 7 2 02.. *. 2. 0. 6 9 0. *.

13 *'1.6408

  • 1.7050
  • 1,7147
  • 1.6590
  • 1.7318
  • 1.6129 *

.8750 *

  • 1. 7741.*. 1. 7243..*. 1. 7141..*. 1. 7851..*. 1. 7121 *. 1. 8432..*.3. 4100..*.

j 14

  • 1.6226
  • 1.6793
  • 1.5829
  • 1.6451
  • 1.4448 *

.8996 *

. 1.7851

  • 1 7368.*. 1. 8610..*. 1. 7951..*. 2. 0528.*.3. 3160 *

.eeeeeee**

15

  • 1.4201
  • 1.0592
  • 1.3055
  • 1.0731
  • F-8UB-Q e.2. 0141..*. 2. 7069.... 2. 2.424.*.2. 7455..*. N-SUB-Q

- Catawha 2 Cycle 7 Core Operating Limits Report Page 96 of 144 Appendix A TABLE 2 (CONTINU3D)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARQIN) - POWER ESCALATION AT 75% POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.0924
  • 1.6718
  • 1.6461
  • 1.8261 + 1.4694
  • 1.6515
  • 1.6376
  • 1.4351 *
  • 2.5811 1.6890
  • 1 7233. 8. 1 5355
  • 1.8977
  • 1.6851
  • 1.6890
  • 1.8939
  • eeeeeeeeeeeeeee......

..eeeeeee***eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6718
  • 1.3987
  • 1.8485
  • 1.6890
  • 1.8635
  • 1.7082
  • 1.6911
  • 1.0667
  • 1 6831.*. 1. 5250.*. 1 6609..*. 1 6523..*.2. 5492..*.
  • 1.6890
  • 2.0155
  • 1.5355
  • eseeeeeeeeeeeeeeeeeeeeeeeen..

10

  • 1.6461
  • 1.8507
  • 1.7254
  • 1.8871
  • 1.7136
  • 1.7200
  • 1.5894
  • 1.3120
  • 1.6647
  • 1.6561
  • 1.7917
  • 2.1300 *

. 1. 7233..*.1. 5339..*. 1 651.4.*.1. 5122 *

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.8261
  • 1.6943
  • 1.8935
  • 1.5401
  • 1.8850
  • 1.6633
  • 1.6515
  • 1.0742 *
  • 1.5355
  • 1.6782
  • 1.5074
  • 1.8538
  • 1.5146
  • 1.7295
  • 1.7347
  • 2.6474
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.4694
  • 1.8742
  • 1.7232
  • 1.8935
  • 1.7168
  • 1.7404
  • 1.4459 *
  • 1.8977
  • 1.e.5169
  • 1.6552
  • 1.5090
  • 1.6841
  • 1.6609
  • 1.5947
  • eneeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.6515
  • 1.7179
  • 1.7286
  • 1.6718
  • 1.7489
  • 1.6290 *

.8793 *

  • 1.6851
  • 1.6523
  • 1.6457
  • 1.7202
  • 1.6523
  • 1.7818
  • 3.3046
  • 4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.6376
  • 1.6954
  • 1.5958
  • 1.6611
  • 1.4576
  • 49050 *
  • 1 6890
  • 1.6486
  • 1.7851
  • 1.7254
  • 1.9796
  • 3.2128
  • es.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.4351
  • 1.0667
  • 1.3163
  • 1.0796
  • 1.8939
  • 2.5515
  • 2.123 eeeeeeeeeeeeeeeeeeeeeeee.7..*.2. 6353..* M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LNVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

H G

F E

D C

4 A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.0549
  • 1.6247
  • 1.5990
  • 1.7789
  • 1.4266
  • 1.6108
  • 1.5979
  • 1.4019 *'

i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.21.*.1. 7995.*eee.5905

  • 1.5966
  • 1.7906 *
  • 2.5028
  • 1.6064
  • 1.6299
  • 1.45..

1

.. e eeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.6247
  • 1.3548
  • 1.8014
  • 1.6429
  • 1.8175
  • 1.6643
  • 1.6526
  • 1.0378 *

~

  • 1. 6064.*.1. 9178..*.1. 4550..*.1. 5966.*e 1. 4463
  • 1 5680.*. 1. 5533
  • 2.4190 *

....eee eeeeeeeeeeeeen 10

  • 1.5990
  • 1.8046
  • 1.6761
  • 1.8410
  • 1.6686
  • 1.6804
  • 1.5487
  • 1.2798 *
  • 1 6299
  • 1.4528
  • 1.5766
  • 1.4470
  • 1.5905
  • 1.5672
  • 1.6881
  • 2.0030
  • e.

....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.7789
  • 1.6483
  • 1.8485
  • 1.4973 + 1.8400
  • 1.6215
  • 1.6129 + 1,0433 *
1.. *. 1. 5 9 2 2.. *e
  • 1. 43 91
  • 1.7 9 62 1 4632.*. 1. 6782..*. 1. 6576
  • 2. 5020.*
  • 1.452 essene.
      • eeeeeeeeeeeee.......

eeeee..

12

  • 1.4266
  • 1.8282
  • 1.6793
  • 1.8475
  • 1.6718
  • 1.7007
  • 1.4084
  • 1.7995
  • 1.4384
  • 1.580..9.*.1. 4572..*. 1. 6676..*. 1. 6281.* 1.9332
  • eeeeeeeeeeeeeeeeeeeeeeee.

... e**eeeee 13

  • 1.6108
  • l'.6740
  • 1.6890
  • 1.6301
  • 1.7093
  • 1.5894 *

.8547 *

  • 1.5905
  • 1.5595
  • 1.5579
  • 1.6686
  • 1.6208
  • 1.7505
  • 3.2092
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 14
  • 1.5979
  • 1.6558
  • 1.5551
  • 1.6226
  • 1.4201 *

.8793 *-

  • 1 1
  • e e 5 9 6 6. *. e e 5 5 2 0.*.
1. 6 8 22...*.1.

6 5 9 0.. *. 1. 9191.*. 3. e.12 2 4

  • eeeee.

15

  • 1.4019
  • 1.0378
  • 1.2841
  • 1.0496
  • 1. 7906... 2. 4210..*.1. 9974 *... 2. 4899..* M-SUB-Q e.

Catawba 2 Cycle 7 Core Operating Limits Report Page 97 of 144 Appendix A TABLE 2 (CONTINJBD)

POWER ESCALATION F-SUB-Q & N-SUB-Q VALUES (F-SUB-Q OP KARGIN)

=

AT 75% POWER, 4 EFPD.

THIS IS LEVEL 6 OF.18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

C B

A

.... H......... G........ F........ E......... D... e e e e e e e e.

eeeeeeeeeeeeeeeeeeeee.

1.5315

  • 1.5037
  • 1.6825
  • 1.3420
  • 1.5240
  • 1.5112
  • 1.3270
  • 8*

.9864

  • 1 1.5629
  • 1.7526 *

'e.2. 4251.*.eee.5604

  • 1.5966
  • 1.4193
  • 1.7687
  • 1.5528
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9
  • 1.5315
  • 1.2713
  • 1.7029
  • 1.5469
  • 1.7211
  • 1.5712
  • 1.5658 *

.9778 *-

  • 1.56

+ 1.8755

  • 1.4172
  • 1.56..21. *.1. 4 0. 4 8. *.1 5 2 9 0.. *.1.

5161. +.2.3 7 91.. *.

e e e e e e.0 4

  • eeeeeeeeeeeeeeeeeeeeeeee.

1.7050

  • 1.5776
  • 1.7436
  • 1.5744
  • 1.5915
  • 1.4619
  • 1.2092
  • 10
  • 1.5037 +

e.1. 5966.*. 1 4151.*.1. 5379..*.1. 4000

  • 1.5454
  • 1.5201
  • 1.6429
  • 1. 9528.*

. eeeeeeeeeeeeeeeeeeeeeeeeeeeee..

1.7500

  • 1.4105
  • 1.7425
  • 1.5305
  • 1.5262 *

.9810.*

11

  • 1.6825
  • 1.5519
  • 1.3.eeeeeeee9 6 6
  • 1. 7 3. 47.. *.1.

4 0. 6 8. *.1 6181.. *.1.

6 019.. *. 2. e. 4 3 53 *

  • 1.4193
  • 1.5562
  • eeeee.

eeeeeeeeeeeeeeeeeeee...

1.5851

  • 1.7500
  • 1.5776
  • 1.6100
  • 1.3291
  • 12
  • 1.3420
  • 1.7307 *

. 1. 7687.*.1. 3960..*. 1. 5363..*. 1. 4014..*. 1. 6019..*. 1. 5655.*.1. 8658.*. -

13

  • 1.5240
  • 1.5797
  • 1.6001
  • 1.5390
  • 1.6194
  • 1.5015 *

.8032 *

  • 1.552.8.*. 1. 520.9.*.1 5106.*. 1 6091
  • 1.5579.*.1. 6871.*. 3. 1191.*.
      • ee.

eeeeeeeeeeee.

14

  • 1.5112
  • 1.5690
  • 1.4683
  • 1.5350
  • 1.3398 *

.8257

  • 1.5629.*. 1. 5130..*.1 6364.*. 1. 5931.*. 1. 8515..*.3. 0307..*-

eeeeee.

15.* 1.3270 *

.9778

  • 1.2124 *

.9875

  • 2.4230
  • M-SUB-Q
  • 1. 7526.e*eeee.3811
  • 1.9463 e.

eeeeeeeeeeeeeeeeeeeeeeee AT 75% POWER, 4 EFPD,, THIS IS LIVIL 5 OF 18 (LEVEL 18 = TOP OF. CORE, LEVEL 1 = BOTTOM)

H G

F

. E D

C B-A

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

.9414

  • 1.4673
  • 1.4437
  • 1.6194
  • 1.2916
  • l'4737
  • 1.4630
  • 1.2863
  • 8
  • eeeeeeeeeeeeeeeeeeeeeeeeeee. 1. 3747..*.1. Y.131
  • 1.4973
  • 1.5067
  • 1.6890
  • 2.3425
  • 1.5130
  • 1.5495
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.4673
  • 1.2177 1.6376
  • 1.4865
  • 1.6579
  • 1.5165
  • 1.5144 *

.9446 *

. 1. 5130..*.1. 8200

  • 1.3708
  • 1.5106.*. 1. 3528..*. 1 4706..*.1. 4595.*.2. 2977..'*.

. eeeeeeeeeeeeeeee 10 a 1.4437

  • 1.6397
  • 1.5165
  • 1.6804
  • 1.5187
  • 1.5350
  • 1.4126
  • 1.1674 *'
  • 1. 5495.*. 1. 3695.*.1 4850
  • 1.3440
  • 1.4873
  • 1.4624
  • 1.5774
  • 1.8792
  • e.

....... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeen 11

  • 1.6194
  • 1.4930
  • 1,6868
  • 1.3591
  • 1.6793
  • 1.4780
  • 1;4758 *

.9457 *

. 1.3747

  • 1 5043
  • 1.3396
  • 1. 6590..*. 1 3453
  • 1.5396
  • 1.5241
  • 2.3406 *

- i

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12

  • 1.2916
  • 1.6675
  • 1.5283
  • 1.6868
  • 1.5230
  • 1.5572
  • 1.2831
  • l
  • 1.7131
  • 1.3434
  • 1.4781
  • 1.3403
  • 1.5067
  • 1.4699
  • 1.7654
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee* eeeeeeeeeeeeeeeeee 13
  • 1.4737
  • 1.5262
  • 1.5444
  • 1.4855
  • 1.5647
  • 1.4523 *

.7733

  • i

. 1. 4973..*.1 4646 *e.....1 4528.*. 1. 5314

  • 1.4624.*. 1. 5791.*. 2. 9412..*.

... e e***ee.

14

  • 1.4630
  • 1.5176
  • 1.4191
  • 1.4844
  • 1.2938 *

.7958 *

    • e 5067..*. 1. 4558
  • 1. 5714.*.1. 5154.*. 1. 7515..*.2. 8568.*.
  • 1 15
  • 1.2863 *

.9446

  • 1.1717 *

.9510

.. 1. 6 8 9 0.. *. 2. 2 9 9 6..* 1. 87 31.. *. 2. 3 2 9 2.. *. M-sUB-Q l

s y

.,4

l r

i l

Catawba 2 Cycle 7 Core Operating Limits Report ~

Page 98 of 144 '

/gppendix A t

l TABLB 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUBS (F-SUB-Q OP MARGIN) - POWER ESCALATION j

AT 75% POWER, 4 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM) l

....H.........G.........F.........E.........D.........C.........B.........A......

~

l I

8*

.8397

  • 1.3184
  • 1.2948
  • 1.4651
  • 1.1642
  • 1.3441
  • 1.3313
  • 1.1706 a j
  • 2 4707..*.1. 5861.*.1. 6281..*.1. 4320.*.1. 7906..*. 1. 5.470.*.1. 5587..*. 1. 7483..*

1 9

  • 1.3184
  • 1.0903
  • 1.4769
  • 1.3388
  • 1.5037
  • 1.3752
  • 1.3794 *

.8568 *

  • 1. 5861..*. 1. 9140.*.1. 4305..*. 1. 5800.*.1. 3994.*. 1. 5233..*.1. 5082..*.2. 3890..*.
  • 1.0581
  • 10
  • 1.2948
  • 1.4791
  • 1.3634
  • 1.5208
  • 1.3730
  • 1.3944
  • 1.2809
  • 1. 6281.*.'1. 4291..*.1. 5537..*. 1 3906
  • 1.5437.*. 1.5130..*ee. 6346 *'1.9489
  • 1

...eeeeeeeee eee..

eeeee.eee..eeen

~ 11

  • 1. 4 6 51
  • 1. 3 4 41
  • 1. 5272
  • 1. 22 63
  • 1. 52 0 8
  • 1. 3 3 66
  • 1. 3 3 8 8 *

.8525 *

  • 1. 4320.*. 1. 5731..*. 1. 3.859..*. 1. 7223.*.1. 3913.*. 1. 5905.*. 1 5697..*. 2. 4353..*

e.

12 a 1.1642

  • 1.5144
  • 1.3816
  • 1.5272
  • 1.3773
  • 1.4126
  • 1.1610
  • l 1

. 1. 7 9 0 6.*. 1 3 8 9 9.*e e. e. 53 3 9

  • 1 3 8 5 9.*.1.

5 503.*. 1 50 4 3.*. 1 8177. *e j.

1 aeeeeee.

l 13

  • 1.3441
  • 1.3827
  • 1.4019
  • 1.3441
  • 1.4201
  • 1.3163 *

.6983

  • l

. 1. 5 4 7 0.. *. 1. 517 7.. *.1.

5 0 2 7.. *.1.

5. 817...*.1.

4 9 7 3.. *.1.

615 4.. *. 3. 0 2 4 4. *e 14

  • 1.3313
  • 1.3827
  • 1.2863
  • 1.3473
  • 1.1717,**

.7197

  • e.1. 5 5 87...*.1.

5 0 4 3. *. 1. 62 81.. *. 1. 5 6 0 4. *. 1. 8 0 4 0. *.2.

9 3 8 2.. * '

.**e.

'15

  • 1.1706 *

.8557

  • 1.0614 *

.8579

  • 1. 7483..*.2. 3909.*.1. 9.423.*. 2. 4230.*. M-8DB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

....H.........G.......F.........E.........D.........C........'.B.........A......

i 8*

.7433

  • 1.1642
  • 1.1460
  • 1.3077
  • 1.0496
  • 1.2231
  • 1.2167
  • 1.0614
  • l

. 2. 6644...*.1. 7141.*. 1. 7537..*. 1 5282.*. 1. 8939.*.1 6190.*. 1. 6244......1. 8373..*

l 9

  • 1.1642 *

.9693

  • 1.3088
  • 1.1931
  • 1.3559
  • 1.2499
  • 1.2531 *.7808 *

. 1. 7141..*. 2. 0557..*.1 5388.*.1. 6890.*. 1. 4759.*.'1. 5931.*. 1. 5783..'*. 2. 498.5.*.-

i 10

  • 1.1460
  • 1.3098
  • 1.2113
  • 1.3591
  • 1.2349
  • 1.2552
  • 1.1620 *

.9500 *

]

  • 1. 7537..*. 1. 5363.*.1. 6657..*. 1. 4781
  • 1 6299.*.1. 5948.*. 1 7131..*.2. 0660
  • i

.e***e ee..

eeee.

11

  • 1.3077
  • 1.1984
  • 1.3655
  • 1.1031
  • 1.3612 + 1.2038
  • 1.2059 *

.7647 *

  • 1.5282.*.1. 6922..*.1 4729
  • 1. 8177..*. 1. 4774 *.... 1. 6744.*. 1 652.3.*. 2 5834.*

seeeeeee 12

  • 1.0496
  • 1.3655
  • 1.2424
  • 1.3666
  • 1.2391
  • 1.2713.* 1.0485 *

. 1. 8 9 3 9.. *. 1. e. 4 6 61. *. 1. e. 619 9. *. 1 47 21.. *.1 6 2 9 9. *. 1. 5 8 0 9. *. 1 9 0 9 0. *.

e...

e..

l 13

  • 1.2231
  • 1.2552
  • 1.2638
  • 1.2102
  • 1.2788
  • 1.1877 *

.6340 *

  • 1. 6190..*. 1. 5870..*. 1. 5843..*.1 66.47..*. 1. 5731..*.1. 6920.*. 3. 1600.*.

14

  • 1.2167
  • 1.2563
  • 1.1663
  • 1.2134
  • 1.0571 *

.6522 *

  • 1. 6244.*.1. 5748.*. 1. 7070.*.1. 6429..*.1.e.8939
  • 3. 0694.*.

eeeee..

15

  • 1.0614 *

.7808 *

.9532 *

.7690

  • 1.8373.*.2. 5007.e*.2. 0586
  • 2.5696..*. M-SUB-Q l

.***ene e

eeeeeeeee..

s

Catawba 2 Cycle 7 Core Operating Limits Report Page 99 of 144 i

Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION 4

l AT 75% POWER, 4 EFPD, THIS IS LEVEL 2 OF 18 J

(LEVEL 18 = TOP OF CORE, LEVEL 1 BOTTOM) e.....................F.........B.........D.........C.........B.........A......

H G

8*

.5890 *

.8954 *

.8889

  • 1.0249 *

.8525

  • 1.0174
  • 1.0239 *

.8589

  • l

... 2489.e*e. 1490.. e e. 2. 18 31. *.1.8 7 9 2.. *.2.

2 4 4 2.. *e e e e. 87 4 3..

  • e e e. 8 5 9 8
  • 2. 18 9 7..
  • l 1

1

  • 3 2

.e

.ee.

e eeeee..

e j

9 *

.9954 * -.7626

  • 1.0089
  • 9339
  • 1.0988
  • 1.0421
  • 1.0421 *

.f57f

  • j

. 2. 1490.*.2 5247..*.1. 9229.*. 2. 0779.*.1 7526

  • 1.8420 *. eeeeeeeeeeeeeeeeeeeeeeeeee f. sh.*e 1.8280
  • 2 i

10 *

.8889

  • 1.0100 *

.9414

  • 1.0667 *

.9992.* 1.0207 *

.9639 *

.7508 *

  • 2.1831
  • 1.9204
  • 2.0675
  • 1.8120
  • 1.9397
  • 1.8792
  • 1.9905
  • 2.5225
  • eeeeeeeeeeeee. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.0249 *

.9382

  • 1.0710 *

.8879

  • 1.0935.*

.9800 *

.9757 *

.6126 *

  • 1.8792
  • 2.069
  • 1.7665
  • 1.9742
  • 1.9635
  • 3.1090
  • eeeeeeeeeeeeene.0.*.1 8063.*. 2. 1749

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen i

12 *

.8525

  • 1.1063
  • 1.0046
  • 1.0999 *

.9982

  • 1.0282 *

.8547 *

  • 2.2442
  • 1.7410
  • 1.9281
  • 1.7579
  • 1.9450
  • 1.8755
  • 2.2512
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.0174
  • 1.0464
  • 1.0260 *

.9864

  • 1.0335 *

.9650 *

.5280

  • e.1. 87 4 3.. *.1.8 3. 5 0.. *.1.

8 7 0 6. *.1.9 6 21.. *.1.8 6 4 6.. *.2 0 016. *. 3. 6 4 6 8.

  • 14
  • 1.0239
  • 1.0442 *

.9682 *

.9810 *

.8611 *

.5441 *

)

  • 1.8598
  • 1.8234
  • 1.9823
  • 1.9528
  • 2.2328
  • 3.5439
  • i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

)

15 *

.8589 *

.6565 *

.7529 *

.6169

  • 2. 1897..*.2. 8682..*.2. 5137..*. 3. 0924..* M-SUB-Q AT 75% POWER, 4 EPPD, THIS 18 JNEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 < BOTTOM) i H

O F

E D

C B

A eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.3716 *

.2849 *

.5269 *

.3395 *

.5430 *

.6944 *

.6351 *

.4894 *

  • 5.0057
  • 6.5 2
  • e e e e e e e e e e e 3 4 5
  • 3. 5 614
  • 5. 47 02..*.3.

4221.e

  • e e e.7 04 4
  • 2. 9 2 04
  • 3.7 4 61 *
    • eeeeee.......

e eeeeeeeeeeeeeeeeeeeeeese 9*

.2849 *

.4691 *

.3299 *

.5687 *

.3866 *

.6351 *

.6640 *

.4091 *

  • 6. 5 3 4 5. *. 3. 9 8 9 3. *. 5 6 5 2 2.. *. 3. 2 9 71.. *. 4 8 0 5 8.. *. 2. 9 412.. *. 2. 7 8 5 2..
  • e. 4 9. 8 9. *.

4 e.

10 *

.5269 *

.3309 *

.5516 *

.3556 *

.5998 *

.6726 *

.5869 *

.2345 *

. 3. 5514.*.5 6411..*. 3.4020..*.5. 2514.*. 3. 1191..*.2. 7665..*. 3. 1739..*. 7. 8485..*.

ee.

11 *

.3395 *

.5719 *

.3566 *

.5676 *

.3856 *

.5987 *

.5816 *

.3716 *

  • 5. 4702.*.3 2784...*.5 2.32.4.*.3.e.2971
  • 4.8380
  • 3.1360
  • 3.1985
  • 4.9884
  • j eeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeese la *

.5430 *

.3888 *

.6040 *

.3866 *

.5955 *

.6223 *

.5034

  • 1
  • 3.4221 *
  • * * *
  • e e... 4. 7 7 4 0.. *. 3. 0 9 9 0.. *. 4 8 218.. *.3.

14 9 7.. *. 3. 0 0 5 5. *. 3. 717 2.. *.

13 *

.6844 *

.6372 *

.6747 *

.6019 *

.6255 *

.5612 *

.3245 *

  • 2.7044
  • 2.9322
  • 2.7560
  • 3.1191
  • 2.9930
  • 3.3429
  • 5.7765 *
  • eeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14 *

.6351 *

.6640 *

.5890 *

.5848 *

.5077 *

.3331 *

  • .2. 920.4.*. 2. 7825.*. 3. 1635.*. 3 1809.*. 3. 6887..*.5. 6301..*.

15 *

.4894 *

.4091 *

.2345 *

.3738

  • 3 7461
  • 4. 4989
  • 7. 8273..*.4.9627
  • M-SUB-Q e.e 2

w

,p s

w+

W m

Cctawba 2 Cycle 7 Core Operating Limits Report Page 100 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 50% POWER,'

4 EPPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F B

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.3663 *

.3020 *

.6073 *

.3791 *-.6255.*

.7518 *

.7090 a'

.5430 *

6. 5335
  • 3.4602
  • 5.5169
  • 3.3429
  • 2. 7657..*.2. 9410
  • 3.8020 *
  • 4.6959 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeee.

eeeeeeeee..

9*

.3020 *

.5398 *

.3652 *

.6512 *

.4220 *

.7133 *

.7261 *

.4712

  • e 6.5335
  • 3.8437
  • 5.6859
  • 3.1779 *e.4.8774.*. 2 9273..*.2. 8506.*eee.3829
  • 4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeee **

eeeeen 10 *

.6073 *

.3663 *

.6265 *

.3845 *-.6747 *. 7251 *..6597 *

.2624 *

  • 3.4602
  • 5.6859
  • 3.2701
  • 5.2859
  • 3.0431
  • 2.8050
  • 3.1121
  • 7.7345
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 11 *

.3791 *

.6544 *

.3866 *

.5955 *-.3823 *..6319 *

.6126 *

.4273 *

  • 4.6820
  • eee 5169.e*e.3. 1652.*. 5 2682
  • 3.1811
  • 4. 8400.*.3. 0227..*.3. 1843
  • 5...

..eeeeeeeeeeee eeeeeeeeeeeeen 12 *

.6255 *

.4252 *

.6779 *

.3834 *

.5344 *

.5558 *'.5152 *-

  • 3 3429.*ee. 8.474..*.3. 0285
  • 4.8252..*.2. 9912
  • 2.9799
  • 3.5819 4

e.e eeeeeeeeee e.

.eeeeeeeeeeeeeeeeeeeee.

13 *..7518 *

.7144 *

.7283 *

.6340 *

.5591 *

.4809 *

.3331 *

  • 2.7 6 57...*.2.916 5.*.2. e.7 9 51
  • 3. 0111
  • 2. 9 6 8 6..'.' 3. 2 4 6 6..*. 5. 2 9 47..
  • eeee..

eeeeeeeeeeeeeeeeeeeee.

14 *

.7090 *

.7261 *

.6619 *

.6158 *

.5184-*

.3406 *

-* 2. 9.410 *.2. 8481.*.3. 1060

  • 3.1715.*.3. 5617..*.5. 1732.*

i l

....eeeeee 15 *

.5430 *

.4712 *'.2624 *

.4284

e.3. 8 02 0.*e e e e. 3 82 9

  • 7.715 6
  • 4. 66 81
  • N-SUB-Q e**eeeeeeeeeeeeeeeeeeeee AT 50% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) l.

B A

e... H..... e e.. O. e e...... F.........I.........D..... e e.. C....... e e........ e e. e e e e 8 *

.5591 *

.9211 *

.9553

  • 1.0699 *

.9286

  • 1.0528
  • 1.0785 *

.8954 *

  • e. 0 0 9 2..*. 2. 8 3 2 6.. *. 2. 8 0 3 8.*.
2. 49 2 5 '
  • 2. 8 5 57 ' ' 2. 5 0 2 2
  • 2. 4 4 3 6
  • 2. 9 0 9 5 *
  • 4...

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9*

.9211 *

.8236

  • 1.0474
  • 1.0046
  • 1.1224
  • 1.0967
  • 1.0699 *

.7176

  • J
  • 2. 8326.*.3 1934.*.2. 5.417..*. 2. 6481.*. 2. 3300.*. 2. 3906.*. 2. 4451.*. 3. 6355.*

10 *

.9553

  • 1.0485
  • 1.0089
  • 1.0742
  • 1.0464
  • 1.0378
  • 1.0185 *

.7925

  • j
  • 2. 8 0 3 8.. *. 2. 5 3. 8 4. *. 2. 6 2 2 9..*.2.

4 0 2 5. *.2.4 8 61.. *. 2. 516 9.. *. 2. 5 5 01.. *. 3. 2 47 2.. *.

.I i

11

  • 1.0699
  • 1.0089
  • 1.0796 *

.8996 *'1.0678 *

.9928 *

.9714 *

.6683 *

  • 2. 4925..*.2. 6390.*. 2. 3981.*. 2. 7776..*. 2. 33.43.*. 2. 5054 8. 2. 5586.*.3. 8189.*.

.i I

12 *

.9266 = 1.1288

  • 1.0517
  • 1.0721 *

.8236 *

.9114 *

.8461 *

. 2. 8557..*. 2. 3175.*. 2. 4749.*. 2. 3258

  • 2.4328
  • 2.4545
  • 2.8309 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.0528
  • 1.1010
  • 1.0432 *.9971 * '.9168 *

.8311 *

.5301 *

  • 2 5022..*. 2. 3833
  • 2. 503.8.*. 2. 4957..*.2. 4467..*. 2. 5552..*. 4.3774.*.

e..

ee..

14

  • 1.0785
  • 1.0721
  • 1.0217 *

.9763 *

.8514 *

.5441

  • e.2 4436
  • 2.4405
  • 2.5417..*. 2. 5484
  • 2.8223 *eeeeeeeeeeeeeee** 2662
  • 4

... eeeeeeeeeeeee..

.eeen 15 *

.8954 *

.7165

  • 7947 *

.6715

l

  • 2.9095.*. 3. 6389... 3. 4390
  • 3. 8038
  • M-SUB-Q eee I

l i

l i

l l

t

l Cctawba 2 Cyde 7 Core Operating Limits Report Page 101 of 144 Appendix A T ABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP kARGIN) - POWER ESCALATION AT 50% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

E B

A e...H.........G**eeeeee.F* *

  • e e e * * *........ D.........C.. e e e e e e e e e e e e e e e e e e e e n e 8 *

.7958

  • 1.2413
  • 1.2638
  • 1.3955
  • 1.1685
  • 1.2895
  • 1.3045
  • 1.1181 *

. 3. 4638

  • 2.3695
  • 2.3640
  • 2.1259..*. 2. 5217
  • 2.2714
  • 2.2442
  • 2e.5885 *

....eeeeeeeeeeeeeeeeeeeeeeeeee

. eeeeeeeeeeeeeeeeeeeeee.

eeeee.

9* 1.2413

  • 1.0796
  • 1.3934
  • 1.3130
  • 1.4212
  • 1.3516
  • 1.3184 *-.8611 *
  • 2...e*eeee..1325
  • 2.2602..*.2. 0579..*.2. 1696.*. 2. 2092..*.3. 3505.*.
  • 2.3695
  • 2.7209 e eeeeeeeeeeeeeeeeeee 10
  • 1.2638
  • 1.3955
  • 1.3345
  • 1.4105
  • 1.3200
  • 1.3173
  • 1.2563
  • 1.0153 *
  • 2. 3640.*.2. 12.92..*. 2. 2187
  • 2.0517
  • 2.1916
  • 2.2164
  • 2.3096
  • 2.8287
  • e.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.3953
  • 1.3184
  • 1.4180
  • 1.1717
  • 1.3977
  • 1.2702
  • 1.2445 *

.8461 *

  • eeeee.9.*. 2. 2515.*.eee.0476
  • 2.4261
  • 2.0385.*eee.2320
  • 2.2664
  • 3.3819
  • 2 2
  • 2.125 eeeeeeeeeeeeeeeeee... e eeeeeeeeeeeeeeeeeeeeeee.

i 12

  • 1.1685
  • 1.4298
  • 1.3355
  • 1.4019
  • 1.2242
  • 1.2413
  • 1.0881 *
  • 2.521 2.5485
  • eeeeee.7..*. 2. 0466..*.2. 1823.*. 2. 0375
  • 2.1515
  • 2.1616
  • ee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.2895
  • 1.3580
  • 1.3248
  • 1.2756
  • 1.2466
  • 1.1599 *

.6694

  • e.2. 2 714. *. 2. 15 9 4. *e e. 2 0 57.. *. 2. 2 2 3 5. *. 2. 15 37.. *.2.

2 7 8 9. *. 4 0 3 7 2.. *.

2 I

14

  • 1.3045
  • 1.3216
  • 1.2606
  • 1.2509
  • 1.0946 *

.6876

  • 3

. 2. 2. 4 4 2...*.2.

2 0 4 5. *.2.3 0 3 2.. *.2 2 5 52.. *.2. 5 3 2 8.*e e e e. 9 2 8 8 *

.. e ee

. ee.

eeeee.

15

  • 1.1181 *

.8611

  • 1.0174 *

.8493

  • 2. 5 8 8 5.*. 3. 3 5 3 3.. *. 2. 8 210..*. 3. 3 6 5 3. *. M -sUB-Q

)

AT 50% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE,' LEVEL 1 m BOTTOM)

H G

F B

D e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e..... e e........C.........B........ A B *

.9778

  • 1.4694
  • 1.4769
  • 1.0204
  • 1.3345
  • 1.4726'* 1.4726
  • 1.2702
  • 2 e. 3 18 9 7.. *. 2. e.16 2 4
  • 2.16 8 0
  • 1. 9 5 9 5.. *. 2. 3. 4 61.
  • e e e.13 91
  • 2.1271
  • 2. 4 3 7 4
  • eeeeeeeeeeeeeeeeeee..

.. e eeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.4694
  • 1.2584
  • 1.6343
  • 1.5251
  • 1.6461
  • 1.5422'* 1.5026 *

.9660

  • e.2.1624.*.2. 4963
  • 1 9485.*. 2. 0888.*.1. 9164.*.2. 0419.*.2. 0764..*. 3. 1774..*e ee..

..e**e ee.

10

  • 1.4769
  • 1.6365
  • 1.5562
  • 1.6536
  • 1.5369
  • 1.5197
  • 1.4309
  • 1.1642 *

. 2. 1680.*.1. 9458..*.2. 042.9.*. 1. 8938.*.2. 0459.*.2. 0620..*.2. 1804.*. 2. 6491.*

11

  • 1.6204
  • 1.5305
  • 1.6547
  • 1.3687
  • 1.6472
  • 1.4780
  • 1.4469 *

.9602 *

  • 1.9595
  • 2.0805
  • 1.8886
  • 2. 2552
  • 1. 8904
  • 2..0930..*.2. 1196.e*eeee.1842
  • 3 eeee**...seeeeeeeeeeeee**ee.

eeeeee j

12

  • 1.3345
  • 1.6547
  • 1.5455
  • 1.6526 1.5165 a 1.5026 a 1.2713
  • j

=

  • 2.3461
  • 1.9050
  • 2.0359 +
  • 2.0172
  • 2.0172
  • 2.3996
  • eeeeeeee**eeeeeeeeeeeeeee... 1. 8878

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13

  • 1.4726
  • 1.5497
  • 1.5283
  • 1.4855
  • 1.5090
  • 1.4084 *.7775 *

. 2. 13 91. *. 2. 0 310.. *. 2. 0 5 2 9. *.2.

0 8 3 6. *. 2. 0 0 9 5. *. 2. 1413.. *. 3. 8 3. e e e *.

47 14

  • 1.4726
  • 1.5069
  • 1.4362
  • 1.4544
  • 1.2798 *

.7990 *-

e. 2. 12 71.. *. 2. 07 2 3.. *. 2. 17 2 5.. *. 2. 10 8 9.. *. 2. 3 8 3 2.. *. 3. 7 3 0 9. *.

15

  • 1.2702 *

.9660

  • 1.1674 *

.9725

  • 2.4374
  • 3 1799.*. 2. 6424 *...... 3. 1697.* M-SUB-Q eeeeee........

1 I

Catawba 2 Cycle 7 Core Operating Limits Report Page 102 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION I

l

. 50% POWER, 4 EFPD, THIS IS LEVEL 14 OF 18 AT f

(LEVEL 18 = TOP OF CORE, LEVEL 1 = POTTOH) l e.....................F.........B........D.........C.........B.........A......

H G

l 8

  • 1.0432
  • 1.5733
  • 1.5712
  • 1.7232
  • 1.4052
  • 1.5572
  • 1.5444
  • 1.3334 *

. 3.2400.*.2. 1676.*.2. 2035..*. 1 9913..*. 2. 3951..*.2. 1887..*. 2. 1933.*. 2. 5101.*

e**

9* 1.5733

  • 1.3366
  • 1.7457
  • 1.6172
  • 1.7554
  • 1.6247
  • 1.5851
  • 1.0078 *
  • 2. 1876.*. 2. 5334.*. 1 9737..*.2. 1326.*. 1. 9537..*.2. 0988..*. 2. 1315.*.3. 2757 *-

ee.

10

  • 1.5712
  • 1.7479
  • 1.6536
  • 1.7682
  • 1.6311
  • 1.6140
  • 1.5058
  • 1.2263 *
  • 2. 2035..*.1. 9710..*.2. 0844.*. 1. 9262..*.2. 0967..*. 2. 1051.*.2. 2467..*. 2. 7264.*

e.

11

  • 1.7222
  • 1.6226
  • 1.7714
  • 1.4555'* 1.7639
  • 1.5744
  • 1.5390
  • 1.0185 *
  • 1 9913..*. 2. 12.40.*.1 9210..*.2. 2987..*. 1. 9262..*. 2. 1499.*.2. 1753.*..3. 2916.*.

e..

12

  • 1.4052
  • 1.7650
  • 1.6400
  • 1.7704
  • 1.6247
  • 1.6172
  • 1.3527
  • ene 3951..*.1. 9430..*.2. 0864.*.1. 9201-* 2.07522.0671
  • 2.4735 *
  • 2

..eeeeeeeeeeeeeeeeeeeeeeeeeees.

13

  • 1.5572
  • 1.6333
  • 1.6236
  • 1.5819
  • 1.6247
  • 1.5123 *

.8268

  • e.2. 1887..*. 2. 0.ee..*. 2. 0957..*. 2. 1401..*eee.0580
  • 2.2047
  • 2.9563
  • 874 2

e eeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.5444
  • 1.5894
  • 1.5112
  • 1.5465
  • 1.3623 *

.8493

  • i

. 2. 1933..*. 2. 1272..*.2. 2396.*. 2. 1642.e*eeee.4563

  • 3.8468
  • 2 l

eeeeeeeeeeeeeee I

15

  • 1.3334'* 1.0078
  • 1.2306
  • 1.0228
  • 2. 5101.*.3 2782..*.2. 7177..*.3. 2738.* M-8UB-Q l

l J

I 1

AT 50% POWER, 4 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

A

....H.........G.........F..........E.........D.........C.........B..... e e e e e e e e e e l

8

  • 1.1171
  • 1.6890
  • 1.6847
  • 1.8443
  • 1.5005
  • 1.6622
  • 1.6472
  • 1.4255 *-

e. 3. 2 8 8 5. *. 2. 2 2 5 3..*. 2. 2 415.. *.2.

0 3 0 0.. *.2.

4 3 5 5. *.2.2 3 8 0.. *. 2. 2 4 6 2.. *.2.

5 6 6 5.. *.

9

  • 1.6890
  • 1.4319
  • 1.8732
  • 1.7329
  • 1.8817 *-1.7372 *-1.6943
  • 1.0742 *
  • 2 2253..*.2. 5662...*.2. 0082..*.2. 1747..*.1. 990.5.*. 2. 1.464.*. 2. 1791.*.3. 3408.*

l.

10

  • 1.6847
  • 1.8753
  • 1.7714
  • 1.8978
  • 1.7489 *'1.7275
  • 1.6086
  • 1.3109
  • 1
  • e e. 4 9 7.. *.2. e. 3 015
  • 2.7 8 77.. *.

2.1

  • 2. 2415..*. 2. 0054.*. 2. 1252.*. 1 9650..*. 2. 1422 8 l

e.

.ee eeeeeeeeeeee 11

  • 1.0443
  • 1.7372
  • 1.9032
  • 1.5604
  • 1.8946
  • 1.6890
  • 1.6526
  • 1.0871
  • eeeeeeeeeeeeeeeeweeeeeeee es.3.3737
  • i
  • 2.0300
  • 2.16 1

eeeee+++.ee**e 59.*ee 9568

  • 2.3367.a 1.9650
  • 2.19so
  • 2.2218
  • eeeeeeee

..ee...

12 a 1.5005

  • 1.8925
  • 1.7586 e 1.9021
  • 1.7468 e 1.7436
  • 1.4533
  • 2 i

. 2. 4355..*. 1. 9795.*. 2 1305.*.1. 9588.e*.2. 12.42.e*eeee.1117

  • 2.5318 *

.. e eeeeeeeeeeeeeee 13

  • 1.6622
  • 1.7468
  • 1.7382
  • 1.6975
  • 1.7511
  • 1.6311 *

.8868 *

  • 2. 2380.*. 2. 1347..*. 2. 1390.*.2. 1879.*. 2. 1024..*. 2. 2533.*.4. 0365.*.

e.

14

  • 1.6472
  • 1.6986
  • 1.6151
  • 1.6611
  • 1.4641 *

.9114

  • e. 2. 2 4 62.. *. 2. 17 47.. *. 2. 2 9 2 9. *. 2. 210 4. *. 2. 514 0.. *.3.

9 27 2..*.

i 15

  • 1.4255
  • 1.0731
  • 1.3152
  • 1.0935

(

  • 2. 5665
  • 3 3434.*.2. 7805.*. 3. 3579.* M-SUB-Q I

r I

l I

f I-

t Catawba 2 Cycle 7 Core Operating Limits Report Page.103 of 144

- Appendix A TABLE 2 (CONTINUED)'

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN)

  • POWER ESCALATION AT 50% POWER,'

4 BFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 = TOP oF CORE, LEVEL 1

s. BOTTOM) e..H........ 0.ee.....F E

D

. C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8

  • 1.1320
  • 1.7222
  • 1.7147
  • 1.8807 *.1.5240
  • 1.6933
  • 1.6750
  • 1.4501 *
  • 3.5088
  • 2.3597
  • 2. 3844.*.2. 1.565
  • 2.6009
  • 2.3804.*. 2.e.3909
  • 2 7179..*.

eeeeeeeeeeeeeeeeeee.

.eeeeeeeeeeeeeeeee.

eeeeee.

9

  • 1.7222
  • 1.4544
  • 1.9117
  • 1.7629
  • 1.9203
  • 1.7661
  • 1.7265
  • 1.0892
  • eeeeeeeeeee. 73.51.*.2. 13.52..*.2. 3205~* 2.1206
  • 2.2947
  • 2.3205
  • 3.5618
  • 2.3597
  • 2

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1,7147
  • 1.9139
  • 1.8014
  • 1.9385
  • 1.7800
  • 1.7639
  • 1.6354
  • 1.3334 *
  • 2.3844
  • 2.1321
  • 2.2718
  • 2.0960
  • 2.2935
  • 2.2959
  • 2.4644
  • 2.9776
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

' I 11

  • 1.8807
  • 1.7671
  • 1.9439
  • 1.5894
  • 1.9353
  • 1.7200
  • 1.6858
  • 1.1031 *.

. 2. 15 6 5. *. 2 3118. *. 2. 0 8 9 9.. *. 2. 5 0 57..

  • e e e. 0 9 7 0
  • 2. 3 5 8 4
  • 2. 37 7 8
  • 3. 6 2 2 4. *.

2 e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

12

  • 1.5240
  • 1.9321
  • 1.7907
  • 1.9439
  • 1.7800
  • 1.7811
  • 1.4801 *-

-**e 6009.*.2. 1082..*. 2. 2802

  • 2.0899
  • 2.2802
  • 2.2612
  • 2.7179 *
  • 2

.ee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 13

  • 1.6933
  • 1.7757
  • 1.7736
  • 1.7297
  • 1.7896
  • 1.6643 *E.9018 *
  • 2 3804.*.2. 2826.*.2. 2850.'*. 2. 3456.*. 2. 2518..*. 2. 4190.*.4. 3509..*.

e..

14

  • 1.6750
  • 1.7307
  • 1.6418
  • 1.6954
  • 1.4908 *

.9275 *:

  • 2.3909
  • 2.3155
  • 2.4560
  • 2.3661
  • 2.6976
  • 4.233 e s e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.7..*e '

I 15

  • 1.4501
  • 1.0881'* 1.3377.* 1.1085
  • F-8UB-Q e.2. 717 9.. *.3.5 6 4 8.*.2. 9 67 4. *. 3. 6 0. 4 3. *. M-SUB-Q AT 50% POWER, 4 BFPD, THIS Z8 LEVEL 11 OF 18 (LEVEL 18 m TOP OF CORE,' LEVEL 1 = BOTTON)

B A

...H.........G......... F.........I.........D.........C..... e e e e e e e e e e e e e e e e e...

s 8

  • 1.1203
  • 1.7147
  • 1.7007
  • 1.8732
  • 1.5112
  • 1.6858'* 1.6643
  • 1.4426 *'

eeeeeeeeeeeeee.21..*eeee.5681

  • 2.2923
  • 2.7745
  • 2.4856
  • 2.4842
  • 2 7915.*.
  • 3.8233
  • 2.53 2

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.7147
  • 1.4416
  • 1.9042
  • 1.7489
  • 1.9139
  • 1.7532
  • 1.7190'* 1.0796 *
  • 2.5321
  • 2.97 51
  • 2. 2 9 47.e* e e e.5028..'ee' 2.2 802
  • 2.4686
  • 2. 4408
  • 3.7 009
  • 2 eeeeeeeeeeeeeeeeeee.

e e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.7007
  • 1.9064
  • 1.7875
  • 1.9321 1.7671
  • 1.7586
  • 1.6226
  • 1.3248
  • i'
  • 2.5681
  • 2.2911
  • 2.4546
  • 2.2565
  • 2.4757.* 2.4742
  • 2.6612 *:3.1554
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.8732
  • 1.7532
  • 1.9385
  • 1.5787 *.1.9299
  • 1.7082
  • 1.6793'* 1.0913
  • enee.

23... 2. 4956..*. 2. 2494

  • 2.7320. *. 2. 2588
  • 2.5530.*.2. 5666 *. e e..... 9 2 0 7.. *. -
  • 2.29 3

.ee.ee ee ee..ee.ee 12

  • 1.5112
  • 1.9246
  • 1.7779
  • 1.9374
  • 1.7671-* 1.7757
  • 1.4705
  • 1
  • 2 7745.*. 2. 2671..*.2.4616
  • 2.2506.*. 2. 4742.*. 2. 4463.*..'2. 9432..*.

l

    • e

. eeeeeeeeeeee.

13

  • 1.6858
  • 1.7629
  • 1.7671
  • 1.7179
  • 1.7832
  • 1.6568 *

.8932 *

  • 2.4856
  • 2.4602
  • 2.4602
  • 2.5395
  • 2.4353
  • 2.6225
  • 4.7695
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen.

14

  • 1.6643
  • 1.7222
  • 1.6290
  • 1.6879
  • 1.4812 .9189 *-
  • 2.4842
  • 2.4353
  • 2.6514
  • eeeeeeeeeeeeeeeeeeeeeeeeeee. 2. 5545..*. 2. 9233..*. 4 6351.*.

15

  • 1.4426
  • 1.0785
  • 1.3291
  • 1.0978
  • 2.7915
  • 3.7 041
  • 3.1463
  • 3. 89 9 5
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 1

-i e

l-Catawba 2 Cycle 7 Core Operating Limits Report '

' Page 104 of 144

)

/qppendix A.

TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION 1

AT 50% POWER, 4 EFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 = TOP OF. CORE. LEVEL 1 m BOTTOM)

I H

G F

E D

C B

A e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee B

  • 1.1235
  • 1.7254
  • 1.7115
  • 1.8871
  • 1.5197
  • 1.6986
  • 1.6793
  • 1.4576 *

. 3.9221.*.2. 56.66.*. 2. 5336

  • 2.2378..*.2. 7358.*.2. 4491..*.2. 4504
  • 2. 7525.*

ee.

.e

..eeeeee.e.

9

  • 1.7254
  • 1.4491
  • 1.9182
  • 1.7597
  • 1.9299
  • 1.7661
  • 1.7339 8'1.0871 *
  • 2.5666
  • 3.0404
  • 2.2790
  • 2.4644
  • 2.2600
  • 2.4339
  • 2.4096
  • 3.6906 *
    • es eeeee**eeee eee eeeee ee eeeee eeeeeeeeeeeee**ee eeeee ee eee ee ee ee eeeeeeeeee.-

10

  • 1.7115
  • 1.9214
  • 1.7982
  • 1.9481
  • 1.7800
  • 1.7736
  • 1.6343
  • 1.3355
  • eeeeeeeee. 2. 2754.*.2. 4574.e***2 2754
  • 2.5072
  • 2.4686
  • 2. 6547
  • 3.1124 *
  • 2.5336 *

..eeeeeeeeeeeeeeeeeee..

eeeeeeeeeeee**e 11

  • 1.8871
  • 1.7650
  • 1.9556
  • 1.5904
  • 1.9471
  • 1.7211
  • 1.6933
  • 1.0978 *
  • 2. 2378..*. 2.4532
  • 2.2623
  • 2. 7906..*. 2. 2911..*.2. 6099.*.2. 6417..*.3. 9.565.*

e.

eeeeeeeeee**eeeeee 12

  • 1.5197
  • 1.9407
  • 1.7907
  • 1.9546
  • 1.7800
  • 1.7929
  • 1.4823
  • l
  • 2.7358
  • 2.2378
  • 2.4913
  • 2.2826
  • 2.5291
  • 2.5086
  • 3.0360
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-13
  • 1.6986
  • 1.7757
  • 1.7832
  • 1.7307
  • 1.0014
  • 1.6729 *

.8986 *

  • 2.4491
  • 2.4203
  • 2.4518
  • 2.5958
  • 2.4956
  • 2.6976
  • 5.0225 *c
          • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee***eeeeeeeeeee 14
  • 1.6793
  • 1.7382
  • 1.6408
  • 1.7029
  • 1.4940'*

.9253 *

  • 2.4504
  • e e e e e e s... 2. 4029
  • 2.6465
  • 2.6273
  • 3.0128
  • 4.87 50 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15

  • 1.4576
  • 1.0860
  • 1.33 98
  • 1.1042
  • 2. 7 52 5
  • 3. 69 3 8
  • 3. 10 57..*. 3. 93 8 5.
  • M-SUB-Q
            • e..

i.

' I AT 50% POWER,'

4 EFPD, THIS IS LIVEL 9 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E-D C

B

'A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.0731
  • 1.6600
  • 1.6418
  • 1.8196
  • 1.4566
  • 1.6376
  • 1.6161
  • 1.4052 *
  • e. 0226.*. 2. 5174.*.2. 4518.*. 2. 1597
  • 2.6677
  • 2.3558
  • 2.3623..*eee.6661 *
  • 4 2

eeeeeeeeeeeeeeeeeeeeeeeeeeee e

eeeeee 9

  • 1.6600
  • 1.3869
  • 1.8496
  • 1.6879
  • 1.8614
  • 1.6965
  • 1.6729
  • 1.0432
  • I l

. 2. 5174

  • 2 9.573..*. 2. 19.47..*.2. 3883
  • 2.1804
  • 2.3533
  • 2.3205
  • 3.6043
  • eeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeee.eee.

I 10

  • 1.6418
  • 1.8518
  • 1.7243
  • 1.8796
  • 1.7082
  • 1.7115
  • 1.5712
  • 1.2852
  • l
  • 2.4518
  • 2.1914
  • 2 eeeeeeeeeeeeeeeeeeeee 3791..*. 2. 1936
  • 2.4298
  • 2.3817
  • 2.5742
  • 3.0639 *.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**.

11

  • 1.8196
  • 1.6933
  • 1.8871
  • 1.5272
  • 1.8785
  • 1.6536
  • 1.6322
  • 1.0528 *
  • 2.1597
  • 2.3791.*. 2. 1815.*. 2. 8446.**2.3218 **ee..... 2.6553.*. 2.6809
  • 3.9207
  • eeeeeeeeeeeeeeees

.... e

.seseeeeeeeeeeeen 12

  • 1.4566
  • 1.8721
  • 1.7190
  • 1.8860
  • 1.7093 *-1.7286
  • 1.4244
  • i

. 2. 6 67 7.. *.2.15 9 7.. *.2. e. 413 6

  • 2. 3131.*e e. 57 57..*. 2. 5 42 5. *.3.

0 8 8 0.*.

2..

l e ee.

13

  • 1.6376
  • 1.7072
  • 1.7211
  • 1.6633
  • 1.7372
  • 1.6097 *

.8622 *

  • 2.3558
  • 2.3444
  • 2.3661..*. 2.6401
  • 2.5306
  • 2.7420eeeeeeeeeeeeeeeeeeeeeeeeeeeee.393.*.

5.1...

    • eeeeeeeeeeeeeeeeeeee.

14 + 1. 6161

  • 1. 6772
  • 1. 577 6
  • 1. 6418
  • 1. 43 62 *

.8868 *

  • 2.362
    • ee..

3..*. 2.e.3155

  • 2.5635
  • 2.6644
  • 3.0639
  • 4.9970
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.4052
  • 1.0432
  • 1.2895
  • 1.0581

+ 2. 6661.*.3 60.43..*.3. 0531.*.3. 8995.*. M-8UB-Q l

I-l, u

l i.

i l

Catawba 2 Cycle 7 Core Operating Limits Report Page 105 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - POWER ESCALATION 1

AT 50% POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 TOP OF CORE, LEVEL 1 = BOTTON)

H F

D C

B A

e ee.....ee..O....eeeeee........E.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8* 1.0592

  • 1.6451
  • 1.6268
  • 1.8057
  • 1.4437
  • 1.6258
  • 1.6086
  • 1.4009
  • e.. 9385.*. 2. 3804.*.2. 3230.*.2. 0455.*.2. 5291.*.2. 22.63.*eeee.2297
  • 2.5115 *
  • 3 2

ee e**eeeeeeeee.**

9

  • 1.6451
  • 1.3720
  • 1.8346
  • 1.6740
  • 1.8485
  • 1.6858
  • 1.6654
  • 1.0378
  • 2.3804
  • 2.8005
  • 2.0769
  • 2.2635
  • 2.0660
  • 2.2240
  • 2.1914
  • 3.4006...*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.6268
  • 1.8378
  • 1.7093
  • 1.8678
  • 1.6965
  • 1.7018
  • 1.5626
  • 1.2788 *
2. 0739
  • 2.2541
  • 2.0759.*ee 2996.*.2 2529
  • 2. 4.32.6.*. 2. 8941.*

2

  • 2.3230 *

.ee.

eeeeeeeeeeeeeeee.

eeeeeeeeee.

11

  • 1.0057
  • 1.6793
  • 1.8753
  • 1.5165
  • 1.8657
  • 1.6429
  • 1.6247
  • 1.0442 *
  • 2. 0455..*.2 2541.*. 2. 0640.*. 2. 6893..*. 2 2.483.*.2. 5958.*. 2. 5696.*.3. 712.4.*.

e.

12

  • 1.4437
  • 1.8603
  • 1.7072
  • 1.8742
  • 1.6975
  • 1.7211
  • 1.4180
  • e 2 5291
  • 2.0455
  • 2.2838
  • 2.2390
  • 2.5262
  • 2.4899
  • 3. 0191
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

.. een 13

  • 1.6258
  • 1.6965
  • 1.7115
  • 1.6526
  • 1.7297
  • 1.6033 *

.8557 *

  • 2.2263
  • 2.2149
  • 2.2378
  • 2.5003
  • 2.4771
  • 2.6859
  • 5.0494
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.6066
  • 1.6697
  • 1.5690
  • 1.6354
  • 1.4298 *

.8804

  • eeeeeeeeeeeeeeeeeeeeeen.17..*. 2. 5545
  • 2.9941
  • 4.9064.*
  • 2.2297
  • 2.1859
  • 2.42

..eeeeeeeeeeeeeeeee...

15

  • 1.4009
  • 1.0367
  • 1.2831
  • 1.0507
  • 2.8844
  • 3.6903
  • M-SUB-Q

... eeeeeeeeeeeeeeeeeeeeeeeee.

AT 50% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.0110
  • 1.5776
  • 1.5604
  • 1.7361
  • 1.3827
  • 1.5647
  • 1.5487
  • 1.3505
  • e.3. 8 2 0 5. *. 2. 2 814. *.2.2. 3 2 0.*.1 9 5 8 6
  • 2. 42 5 8.*. 2. 116 5. *. 2. 118 5..*.2.3 713.
  • 9
  • 1.5776
  • 1.3120
  • 1.7639
  • 1.6054
  • 1.7789
  • 1.6204
  • 1.6044 *

.9960 *

  • e 2 814.*. 2. 6 9 2 6.*.1. 9 9 47.. *. 2. 17 4 9.*.1. 9 7 8 3..*.2.12 3 7..*. 2. 0 8 4 9. *.3.

2 2 3 5. * -

  • 2 10
  • 1.5604
  • 1.7661
  • 1.6386
  • 1.7971
  • 1.6290
  • 1.6386
  • 1.5015
  • 1.2306
  • j
  • 2.2320
  • 1.9919
  • 2.1716
  • 1.9928
  • 2.2127
  • 2.1565
  • 2.3230
  • 2.7386
  • 1
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 11
  • 1.7361
  • 1.6108
  • 1.8046
  • 1.4544
  • 1.7961
  • 1.5787
  • 1.5658
  • 1.0025 *

. 1. 9f.96..*.2. 1662..*.1. 9810

  • 2.5942
  • 2.1630
  • 2.5218
  • 2.4560
  • 3.5309 *
        • e**e,*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.3627
  • 1.7096
  • 1.0386
  • 1.8046
  • 1.6301
  • 1.6579
  • 1.3634 *
  • 2.4258
  • 1.9506
  • 2.1981
  • 2.1533
  • 2.5072
  • 2.4491
  • 2.9313
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.5647
  • 1.6301
  • 1.6483
  • 1.5883
  • 1.6665
  • 1.5433 *

.8204

  • i

. 2. 1165.*. 2. 1154.* 2 1426.*.2. 5086..*. 2.4367

  • 2.6482..*.4 9176..*

l eeeeeeeeeeee....

l 14

  • 1.5487
  • 1.6086
  • 1.5080
  • 1.5754
  • 1.3741 *

.8439

  • l
  • 2.1185
  • 2. 0799.*.2. 3143.*. 2. 4435..*e. 9096.*.4. 7766.*

2 15

  • 1.3505 *

.9960

  • 1.2349
  • 1.0078
  • 2. 3713..*. 3. 2259
  • 2. 7299.*. 3. 5137..* M-SUB-Q-1 1

i f

l' l

l t

1 1

Catawba 2 Cycle 7 Core Operating Limits Report -

Page 106 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 50% POWER, 4 EFFD, THIS IS LEVEL 6 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOH) e...H.........O........F........e.........D.........C.........B......ee.A.....e E

8*

.9339

  • 1.4683
  • 1.4480
  • 1.6194
  • 1.2841
  • 1.4608
  • 1.4448
  • 1.2606
  • e 3. 7 316.. *.2.2. 3 6 7.. *.2.

19 81

  • 1. 9 2 0. 4. *.2.3. 9 0 9. *.2.07 0 9. *. 2. 07 8 9.. *. 2. 3 2 5 5.
  • eee eeeeeeeeee 9
  • 1.4683
  • 1.2145
  • 1.6440
  • 1.4908
  • 1.6611
  • 1.5000
  • 1.4994 *

.9264

  • 6547
  • 1.9533.e*. 2. 1416
  • 1 93931*.... 2. 000.9.*.2.0388 *

.eeeeee.739.*.

3.1..

  • 2.2J67
  • 2 i

)

eeeeeeeeeeee eeeeee.e

. ee eeeeeeeeeeee 10

  • 1.4480
  • 1.6472
  • 1.5208
  • 1.6783
  • 1.5144
  • 1.5315
  • 1.3977
  • 1.1470 *
  • '2. 1981.*.1. 9.507..*.3. 1363.* 1. 9.471.*.2. 1684.* 2. 1051.*.2. 2742.*.2. 6809.*.-

)

e.

11

  • 1.6194
  • 1.4962
  • 1.6858
  • 1.3516
  • 1.6772
  • 1.4694
  • 1.4608 *

.9307

  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 0..*eee.1021
  • 2.4546
  • 2.3857
  • 3.4604 *
  • 1.9204
  • 2.1321
  • 1.9358
  • 2.538 2

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.2841
  • 1.6708
  • 1.5240
  • 1.6847.* 1.5155
  • 1.5476
  • 1.2681 *
  • 2. 3 9 0 9. *.1.9 2 0. 4. *. 2. 1. 5 3 3. *.2.

0 9 2 9. *. 2. 4 312.. *.2.

3 7 6 5. *. 2. 8 5 5 9. *e e.

q 13

  • 1.4608
  • 1.5176
  • 1.5401
  • 1.4780
  • 1.5562
  • 1.4373 *

.7604 *

  • 2.0709
  • 2.0739
  • 2.0909
  • 2.4408
  • 2.3636
  • 2.5773
  • 4.8191 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.4448
  • 1.5037
  • 1.4041
  • 1.4705
  • 1.2788 *

.7840

  • i

. 2. 0789.*.2 0340.*. 2. 2647..*. 2. 3713..*. 2. 8316.*. 4 6786.*.

15

  • 1.2606 *

.9253

  • 1.1513 *

.9361

  • 2. 3255.*eee.1762
  • 2.6727
  • 3.4439
  • M-SUB-Q 3

e**.

e eeeeeeeeeeeeeeeeeeeeeee.

AT 50% POWER,-

~4 EFPD,- THIS IS LEVEL 5 OF 18.

(LEVEL 18 s TOP OF CORE, LEVEL 1 e BOTTON)

H 0

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8804

  • 1.3891
  • 1.3709
  • 1.5369
  • 1.2188
  • 1.3923
  • 1.3794
  • 1.2059 *
  • 3.5453
  • 2.1662
  • 2.1321
  • 1.8610..*.2. 3168
  • 1.9993
  • 2. 0048
  • 2.2413
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

...e eeeeeeeee.

eeeeeeeeeeeeeen 9

  • 1.3891
  • 1.1492
  • 1.5594
  • 1.4137 + 1.5776
  • 1.4362
  • 1.4309 *

.8836 *

  • 2.1662
  • 2.5712
  • 1.8910
  • 2.0749
  • 1.8698
  • 2.0030
  • 1.9648
  • 3.0683
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.3709
  • 1.5615
  • 1.4426
  • 1.5958
  • 1.4405
  • 1.4576
  • 1.3323
  • 1.0935 *
    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 0869.*eee.0254
  • 2.1848.*. 2. 5803.*.
  • 2.1321
  • 1.8878
  • 2.0670
  • 1.8787
  • 2... e 2

eeeeemene...

11

  • 1.5369
  • 1.4201
  • 1.6022
  • 1.2852
  • 1.5947
  • 1.3998 *~1.3923 *

.8846 *

. 1. 8610.*.2. 0640

  • 1.8674
  • 2.4353......eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.. 3249..*
  • 1.9993
  • 2.3032
  • 2.2671
  • 3 12
  • 1.2183
  • 1.5872
  • 1.4501 8 1.6022 *'1.4426 8 1.4758
  • l'2092
  • e.2. 3168..*.1. 8570..*. 2. 0729
  • 1.9910
  • 2.2996
  • 2.2448
  • 2.6826
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3923
  • 1.4448
  • 1.4662
  • 1.4073
  • 1.4833
  • 1.3709 *

.7240 *

  • 1.9993
  • 1.9956
  • 2.0123
  • 2.2898
  • 2.2332
  • 2.4353
  • 4.5556
  • I eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 14
  • 1.3794
  • 1.4341
  • 1.3388'* 1.4019
  • 1.2188 *

.7454 *.

j

  • 2.0048
  • 1.9595
  • 2.1760
  • 2.2529
  • 2.6595
  • 4.4253 *-

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.2059 *

.8825

  • 1.0978 *

.8900

  • 2.5727
  • 3.3072
  • M-SUB-Q
  • 2

....eeeeeeeeeeeeeeeeeee l

)

Catawba 2 Cycle 7 Core Operating Limits Report

' Page 107'of 144 Appendix A TABLE 2_(CONTINUED)

F-SUB-Q & M.SUB-Q VALUBS (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 50% POWER, 4 BFPD, THIS IS LNVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

.... H......... G... e e e e e e e e e e e e e e e........ D......... C..

........B A

F E-eeeeeeeeeeeeee.

.7765

  • 1.2316
  • 1.2134
  • 1.3720
  • 1.0849
  • 1.2520
  • 1.2391
  • 1.0828
  • 8 *
  • 3.6840
  • 2.2413
  • 2.2297
  • 1.9341
  • 2.4163
  • 2.0630
  • 2.0739
  • 2.3205
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.2316
  • 1.0153
  • 1.3869
  • 1.2552
  • 1.4084
  • 1.2841
  • 1.2852 *

.1915

  • e.2. 2 413. *.2.67 9 3.. *. 1. 9 6 3 9. *.2.

16 51.*. 1. 9 2 47.. *.2.0. 6 9 0..*. 2. 02 6 4.*.

3. 187 9 *

. gee.

10

  • 1.2134
  • 1.3891
  • 1.2788
  • 1.4255
  • 1.2841
  • 1.3055
  • 1.1920 *

.9778

  • e 2. 2297
  • 1.9612
  • 2.1543
  • 1.9419
  • 2.1586
  • 2.0839
  • 2.2518
  • 2.6694
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

'11

  • 1.3720
  • 1.2606
  • 1.4309
  • 1.1438
  • 1.4244
  • 1.2488
  • 1.2466 *

.7883 *

  • 1.9341
  • 2.1533
  • 1.9298
  • 2.50..14.*. 2. 0245.*.2. 3406.*. 2. 2923.*.3. 4330..*.

e eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.0849
  • 1.4180
  • 1.2927
  • 1.4319
  • 1.2863
  • 1.3205
  • 1.0796
  • e.2. 4163.*.1. 9111..*.2. 1416
  • 2.0160
  • 2.3143
  • 2.2471
  • 2.7231.*.

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..

13

  • 1.2520
  • 1.2916
  • 1.3130
  • 1.2552
  • 1.3280
  • 1.2263 *

.6458 *

  • 2. 0630..*.2. 0611.*.2. 0699..*. 2. 32.55.*eeee.2355
  • 2.4312
  • 4.5894
  • 2 e.

eeeeeeeeeeeeeeeeeeeeeee.

'14

  • 1.2391
  • 1.2884
  • 1.1974
  • 1.2552
  • 1.0892 *

.6651

  • e e. 07 3 9.. *. 2. 0 216.. *.2.
2. 42 4. *. 2. 2 7 7 8. *. 2. 7 010. *. 4 4 57 2..*.
  • 2 15
  • 1.0828 *

.7904 *

.9821 *

.7925

I

  • 2. 3205.*.3. 1903.*.2. 6612..*ee. 4140.* M-SUB-Q 3.....

e.

AT 50% POWER, 4 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18.= TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F B

D C

B A

i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

B*

.6790

  • 1.0731
  • 1.0603
  • 1.2092 *

.9650

  • 1.1256
  • 1.1181
  • 49703 *

. 3. 8070..*.2. 3739.*. 2. 38.44... 2. 0572..*.2. 5470.*.2. 1554.*.2. 1586

  • 2.4353 *

[

.e.see..

ee.

9

  • 1.0731 *

.8911

  • 1.2134
  • 1.1042
  • 1.2531
  • 1.1513
  • 1.1535 *

.7122

  • e.2. 3 7 3 9.. *. 2. 8 3 5 3. *.2.

0 9 8 0

  • 2. 2 9 9 6..*. 2. 0.151. *.2.

15 4 3.*.2. 115 4.*. 3. 3 2 7 5.*.

..ee 10

  • 1.0603
  • 1.2145
  • 1.1213
  • 1.2574
  • 1.1406
  • 1.1599
  • 1.0678 *

.8675 *

  • 2. 38.44.*. 2e.0950
  • 2.2935
  • 2.0542
  • 2.2553
  • 2.1793
  • 2.3431
  • 2.8151
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1

11

  • 1.2092
  • 1.1085
  • 1.2627
  • 1.0153
  • 1.2574
  • 1.1096
  • 1.1085 *

.6994 *

.... 2. 2886.*. 2. 0.42G.*. 2. 5942..*. 2. 09.80

  • 2.3949
  • 2. 3610.*.3. 601,3,*
  • 2.0572 e...

eeeeeeeeeeee.

.ee.

e 12 S

.9650

  • 1.2616
  • 1.1461
  • 1.263s
  • 1.142e
  • 1.1727 *.sels *
  • 2.5470
  • 2.0002
  • 2 eeeeeeeeeeeeeeee... 2. 2390.*. 2. 0899.*eee.3962
  • 2.3267
  • 2.7825
  • eeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.1256
  • 1.1567
  • 1.1674
  • 1.1160
  • 1.1792
  • 1.0924 *

.5783 *

  • 2. 1554..*.2. 1458
  • 2 1651..*. 2.e.3804
  • 2. 3143..*.2. 5218.*.4. 7142..*

e.

.ee...

e.

14

  • 1.1181
  • 1.1556
  • 1.0731 + 1.1149 *

.9703 *

.5965 *

  • 2.1586
  • 2.1103
  • eeeeeeeeeeeeeeeeeee.2. 3330
  • 2.3469
  • 2.7595
  • 4.5749 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15 *

.9703 *

.7122 *

.8707 *

.7026

  • 2. 0060.*.3. 5805
  • M-SUB-Q

..eee i

i I

l l

l l

\\

r l

l'

Catawba 2 Cycle 7 Core Operating Limits Report

. Page 103 of 144 Appendix A TABLE'2 (COW.'INUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - POWER ESCALATION AT 50% POWER, 4 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 s BOTTOM)-

H G

F E

D C

. B A

eneseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8*

.5312 *

.8140 *

.8107 *

.9339 *

.7733 *

.9253 *

.9296 8

-.7765 *

  • 4.5365
  • 2.9372
  • 2.9532
  • 2.5247
  • 3.006E
  • 2.4927
  • 2.4714
  • 2.9037
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

..9478 *

.9478 *

.5933

  • 9*

.8140 *

.6919 *

.9221 *

.8536

  • 1.0025 *

.i-e eeeeeeeeeeeee.6

  • 2.6114
  • 2.8187
  • 2.3778
  • 2.4799
  • 2.4435 3.8137 *
  • 2.9372
  • 3.446.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10 *

.8107 *

.9232 *~.8589 *

.9725 *

.9104 *

.9307 *

.8750'*

.6769 *

  • 2. 9532..*.2. 6067
  • 2.8279
  • 2.5144
  • 2.6563
  • 2.5727
  • 2.7044
  • 3.4248
  • e.

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11 *

.9339 *

.8568 *

.9768 *

.8075 *

.9971 *

.8932 *

.8857 *

.5537

  • esee.247..*. 2. 8023
  • 2.4999
  • 3.0704
  • 2.4757
  • 2.7754
  • 2.7595
  • 4.2980
  • 2.5 e

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12 *

.7733

  • 1.0089 *

.9168

  • 1.0025 *. 9082 * '.9361 *

.7754 *

          • ee... 2. 3610..*.2. 6369..*.2. 4630
  • 2.7933
  • 2.6909
  • 3.2187 *
  • 3.0065 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

4 13 *

.9253 *

.9521 *

.9361 *

.8986 *

.9414 *

.8771 *

.4777'*

j

  • 2.4927
  • 2.4714
  • 2.5605
  • 2.7595
  • 2.6760
  • 2.8921
  • 5.2963
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee *eeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 14 *

.9296 *

.950' *

.8793 *

.8921 *

.7818 *

.4916

  • 4394..*.2. 6.943e*eee.7420
  • 3.1926
  • 5.1454
  • 2.4714
  • 2..

2 e

eeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeee.

j 15 *

.7765 *

.5933 *

.6801 *

.5569

  • 2. 9037
  • 3.8171
  • 3.4140
  • 4.272 6
  • N-SUB-Q e.

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

AT 50% POWER, 4 NFPD, THIS IS LEVEL' 1 OF 18 i

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D' C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.3299 *

.2528 *

.4712 *.3031 *

.4862 *-.6148 *

.5698 *

.4370

  • eeeeeeeeeeee... 7. 3680
  • 4.5894
  • 3.6013.*.3.8890
  • 4.9798
  • es. 8768.*eeee.9144
  • 6...

8 4.8191

  • eeeeeeeeeeeeeeeeeeeee. eeeeeeeeeeeeeeeee 9*

.2528 *

.4188 *

.2945 *

.5087 *

.3449 *

.5708 *

.5955 *

.3652

  • 4
  • 8.9144
  • 5.4223
  • 7.6680
  • 4.4849
  • 6.5051 *-3.9421
  • 3.7156
  • 5.9922
  • eeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10 *

.4712 *

.2945 *

.4937 *.3170 *

.5376 *

.6040 *

.5269 *

.2078 *.

e.. 8191..*.7. 6680.*. 4. 6736.*. 7. 1847..*. 4 2350.*. 3. 7542..*.4 2895.*10.6447 *

  • 4

...eeeeeeee.

I 11 *

.3031 *

.5119 *

.3181 *

.5066 *

.3438 *

'.5355 *

.5216 *

.3309 *

  • 7.3680
  • 4.4616
  • 7.1492
  • 4.6685 ***6.7800
  • 4.3939
  • 4.4435
  • 6.6766.*.

1 eseeeeeeeeeeee**esese**************

                          • .a

..e**

e******e lf 12 *

.4"C2'*

.3470 *.5415 *.3443 *

.5312 *.3551 *

.4503

  • t
  • 4.5894
  • 6.4566
  • 4.2103
  • 6.7483
  • 4.4710
  • 4.2895
  • 5.2834
  • j eeeeeeeeeeeeeee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j-13 *

.6148 *

.5730 *

.6073 *.5387 *

.5612 *

.5034'*

'.2902 *

  • 3.6013
  • 3.9314
  • 3.7380
  • 4.3717..*.4. 2642..*.4 7925..*.8 3155.*.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14 *

.5698 *

.5965 *

.5291'*

.5248 *

.4552 *

.2977 *

  • 3. 8890
  • 3.7124
  • 4.2726
  • 4.4208..*. 5. 2450....... 0979..*
  • 8 t

eeeeee.eeeeeeeeeeeeeee.....ee I

15 *

.4370 *

.3652 *

.2078 *.3331

e. 4 9 7 9 8.. *. 5. 9 9 2 2.. *.10.

618 6. *. 6. 8 4 4 2..

  • M-SUB-Q 4

4 1

l

)

4 1

1 Catawba 2 Cycle 7 Core Operating Limits Report Page 109 of 144 Appendix A

)

TABLE 2 (CONTINUED)

F-SUB-Q E N-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 30% POWER, 4 BFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

O F

E C

B A

e...H.. eeeeeeeeeeeeeeeeeeeeeeeee........D......eeeeeeeeeeeeeeeeeeeeeeeeee.

8 *

.3620 *

.3020 *

.6126 *

.3823 *

.6351 *

.7743 *

.7304 *

.5537 *

  • 15 5605.*18 6505.*.9. 1948 *14 7323..*.8. 8692..*.7. 2745..*.7. 7118.*.10. 1730.*

e..

9*

.3020 *

.5409 *.3684 *

.6597 *

.4295 *

.7347 *

.7486 *

.4787 *

  • 18 15
  • 7.5242 *11.7661
  • e.

6505.*10 4147e*eeee.2891

  • 8.5381 *13.1158
  • 7.6668 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10 *

.6126 *

.3684 *

.6340 *

.3888 * -.6897 *

.7476 *

.6779 *

.2635

  • e e e e e e e e e e e e e e e e e e e e e e e.8 42..*.14 4 8 8 8. *. 8. 16 6 8..*.7.

5 3 5 0.. *. 8. 3 0 8 8. *.21. 37 9 8. *

  • 9.1948 *15.2891
  • 8.8 11 *

.3823 *

.6629 *

.3909 *

.6019 *

.3888 *

.6458 *

.6297 *

.4305 *

  • 14.7323
  • 8.4967 *14 4094
  • 9. 3584.*14 4888..*.8 7221.*.8. 9446.*.13.0832
  • eeeeeeeeeeeeeeeeee..

eeeeee...........

eeeeeeeee 12 *

.6351 *

.4316 *

.6940 *

.3898 *

.5387 *

.5698 *

.5269

  • 8.8692 *13.0507
  • 8.1164 *14.4490 *10.4561
  • 9.8862 *10.6899
  • eneseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeen 13 *

.7743 *

.7358 *

.7508 *

.6480 *

.5741 *

.4916 *

.3363

  • e.. 2 7 4 5.*.7. 6. 5 57.. *.7.

5 0 2 8.*e e e e. 6 9 3 3

  • 9 812 4.
  • 11. 4 5 8 5.* 16 7 4 9 8 *
  • 7 8

eeeeeee...

...ee..

eeeen 14 *

.7304 *

.7497 *.6801 *

.6330 *

.5301 *

.3438 *

  • -7. 7118..*. 7. 5135.*.8. 282.6.*. 8. 8992..*10.,6251.*.16. 3845.*.

e.

15 *

.5537 *

.4787 *-.2645 *

.4327

  • 10.173 0
  • 11. 7 6 61
  • 21. 2 9 3 3
  • 13. 018 4
  • M-8UB-Q eeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeee.

P AT 30% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H O

F-E D

C B

A

    • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8 *

.5676 *-.947P *

.9917

  • 1.1117 *

.9585

  • 1.0967
  • 1.1235 *

.9243

  • e 2.1411
  • 7.27f**.e.6 P490.*.6. 1992
  • 7.1897
  • 6.2840
  • 6. 1342..*.7. 4563..*.-
  • 1 ee...eeeeee

.eeeeeeeeeeeeeeeeeeeeeee 9*

.9478 *

.84F

  • 1.3913
  • 1.0474
  • 1.1727
  • 1.1449
  • 1.1160 *

.7358

  • seeeeeeeeeeeeeee.765.*.6. 0194
  • 6.1754
  • 9.3665 *
  • 7. 2 7 0 9.. *. 8.14... e *e e e e. 314 8
  • 6

.5795

  • 5.8....

.eeeeeeeeeeeeeeeeeeeeee e.

en 10 *

.9917

  • 1.7s35
  • 1.0507
  • 1.1213
  • 1.0924
  • 1.0839
  • 1.0603 *

.8140

  • 6.9490
  • 6.3024
  • 6.5594
  • 6.14..59.*. 6. 3086.*.6. 3585.*.6. 4998..*.8. 4668.*..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.1117
  • 1.051
  • 1.1278 *

.9318

  • 1.1149
  • 1.0357
  • 1.0110 *

.6844 *

  • 6. 1992..*. 6 5527..*. 6. 1109 *. 7..,3.963..*eee.1814 **6.6544
  • 6.8165 *10.0701
  • 6 e.

ee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12 *

.9585

  • 1.1792
  • 1.036'
  • 1.1203 *

.8557 *

.9489 *

.8750 *

  • 7.1897
  • 5.8445
  • t 212
  • 6.1518
  • 8.0536
  • 7.2627
  • 7.8761
  • eeeeeeeeeeeeeeeeeeeeeeese seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.0967
  • 1.1492
  • 1.0903 = 1.0410 *

.9543 *

.8611 *

.5409 *

  • 6.2840
  • 5.9970
  • 6.3210
  • 6.6 7

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.202.e*eeee.2220

  • 8.0035 *12.7422
  • eeeeeeeeeeeeeeeeeeeeeeen 14
  • 1.1235
  • 1.1192
  • 1.0646
  • 1.0164 *

.8814 *

.5548 *

  • 6.1342..*. 6. 1577..*.6. 4736..*...

7806

  • 7.8187 *12.4224
  • e...

..eeeeeeeeeeeeeeeeeeeeeeee 15 *

.9243 *

.7358 *

.8172 .6676

  • 7.4563
  • 9.3665
  • 8.4335 *10.0230
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

S

C:etawba 2 Cycle 7 Core Operating Limits Report Page 110 of 144 -

Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 30% POWER, 4 EFPD, THIS IS. LEVEL 16 OF 18'

(.

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C'

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8118

  • 1.2895
  • 1.3227
  • 1.4608
  • 1.2145
  • 1.3462
  • 1.3623
  • 1.1567 *
  • 9.0099
  • 5.6974
  • 5.5543
  • 5.0290
  • 6.0225
  • 5.4571
  • 5.3928
  • 6.3515
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeee**eeee 9
  • 1.2895
  • 1.1181
  • 1.4641
  • 1.3794
  • 1.4919
  • 1.4159
  • 1.3794 *..8857
  • eeeeeeeeeeeeeeeese.888.*.5. 3258
  • 8.2582
  • 4.9243
  • 5.1...

e. 5. 6 9 7 4. *. 6 5 417.. *. 5. 018 0. *. 5. 3 2 5 8

  • eeeeeeeeeeeeeee 10
  • 1.3227
  • 1.4662
  • 1.4009
  • 1.4844
  • 1.3934
  • 1.3827
  • 1.3109
  • 1.0474 *
  • 5.5543
  • 5.0107
  • 5.2444
  • 4.9492
  • 5.3134
  • 5.6043
  • 7.0139
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 5.2726 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.4608
  • 1.3859
  • 1.4919
  • 1.2220
  • 1.4651
  • 1.3313
  • 1.2991 *

.8697

  • eeeeeeeeeeeeeeeeeeeeeeeee.3..*.5.a.9856
  • 5.0143
  • 5 5186.*. 5. 6551
  • 8 4.478..*.
  • 5.0290
  • 5.3011
  • 4.924 eeeeeeeeeeeeeeeee....

eeeeee.

12

  • 1.2145
  • 1.5015
  • 1.4019
  • 1.4705
  • 1.2841
  • 1.3013
  • 1.1288 *
  • 6.5082 *
  • 6.0225
  • 4.8927
  • 5.2404
  • 4.9961
  • 5.7211
  • 5.6458
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3462
  • 1.4244
  • 1.3902
  • 1.3377
  • 1.3077
  • 1.2001 *

.6865

  • ee. 4571
  • 5.1576
  • 5.2848
  • 5.4921
  • 5.6180
  • 6.0812 *10.6545 *
  • 5 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.3623
  • 1.3827
  • 1.3163
  • 1.3066
  • 1.1363 * -.7047
  • 5.3928
  • 5.3134
  • 5.5815
  • 5.6226
  • 6.4652 *10.3792
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.1567 *

.8857

  • 1.0507 *

.8739

  • F*SUB-Q i
  • 6.3515
  • 8.2582
  • 6 eseeeeeeeeeeeeeeeeee. 9925..*.8.4064
  • M-SUB-Q

... eeeeeee.

AT.30% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 I

(LEVEL 18 = TOP OF CORE, LNVEL 1 = BOTTOH)

D C

B A

[

....H.........G.........F........ ' E. e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e n 8

  • 1.0003
  • 1.5283
  • 1.5476
  • 1.6986
  • 1.3891
  • 1.5369
  • 1.5358
  • 1.3130 *
  • 7.3765
  • 4.8793
  • 4.8185
  • 4.3902
  • 5.3120
  • 4.8521
  • 4.8555
  • 5.6793
  • eeeeeeeeeeeeeeeeee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.5283
  • 1.3055
  • 1.7200
  • 1.6033
  • 1.7329
  • 1.6151
  • 1.5712 *

.9939

  • i eeeeeeeeeeeee.6519..*.4. 3355.*. 4.6512
  • 4.3033
  • 4.6172
  • 4.7463
  • 7.4242 *
  • 4.8793
  • 5.

I eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1

10

  • 1.5476
  • 1.7232
  • 1.6365
  • 1.7372
  • 1.6161
  • 1.5947
  • 1.4930
  • 1.2006
  • e.4. 8185.*. 4 3274..*.4 5568.*.4. 2927..*.4.6142
  • 4.6762
  • 4.9948
  • 6.2112**e e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.6986
  • 1.6097
  • 1.7436
  • 1.4287
  • 1.7297
  • 1.5508
  • 1.5101 *

.9960 *

]

. 4 3902..*.4. 6326..*.4.276.9

  • 5. 1647
  • 4.3113
  • 4.8086
  • 4.9381
  • 7.4869
  • i

.....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 12

  • 1.3891
  • 1.7425
  • 1.6258
  • 1.7361
  • 1.5926
  • 1.5776
  • 1.3195
  • i
  • 5 3120.*.4 2795..*.4 5868
  • 4.29..54.*. 4 682.4.*. 4 7269
  • 5.6516.*

e..

.. e e ee.

. eeeeeee.ee.

..eeeeee...

l 13

  • 1.5369
  • 1.6247
  • 1.6044
  • 1.5583
  • 1.5840
  • 1.4694 *'.7990
  • 4 4

l

  • 4.852 1..*. 4. 5898..*.4. 6481..*eee.7854.*eee.7078
  • 5.0749
  • 9.2355
  • e eeeee eeeeeeeeeeeeeeeeeeeeeeee eseeee.

14

  • 1.5358
  • 1.5744
  • 1.4963
  • 1.F 87
  • 1.3291 *

.8215

  • l
  • 4. 8555.*. 4. 7366 *...... 9 7 7 0.. *. 4.. s.C ?

4

  • 5.6106
  • 8.9827
  • e.

eeeeeeeeeeeeeeeeeeee.

l 15

  • 1.3130 *

.9928

  • 1.2038 *

' ;03

  • 5.6793
  • 7.4323
  • 6.1947 * ',.45..

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.48.*. M-SUB-Q I

l k

w

+mm

Catawba 2 Cycle 7 Core Operating Limits Report Page 111 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP KARGIN)

. POWER ESCALATION AT 30% POWER, 4 EFPD, THIS IS LEVEL 14 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 - BOTTOM)

B A

....H......... G.. e e e e e e F* e e e e e e..E.........De e......C. e e e e e e e e e e e e e e e e e e

  • e e e e 8
  • 1.0656
  • 1.6343
  • 1.6429
  • 1.8025
  • 1.4587
  • 1.6204
  • 1.6054
  • 1.3753
  • l
  • 6.9848
  • 4.6304
  • 4.6062
  • 4.1984
  • 5.1027
  • 4.6702
  • 4.7138
  • 5.5031
  • eeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.6343
  • 1.3837
  • 1.8336
  • 1.6975
  • 1.8432
  • 1.6975
  • 1.6515
  • 1.0346 *
  • 4.6304
  • 5.3792
  • 4.1273
  • 4.4580
  • 4.1057
  • 4.4580
  • 4.5823
  • 7.1945
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.6429
  • 1.8368
  • 1.7339
  • 1.8539
  • 1.7104
  • 1.6890
  • 1.5658
  • 1.2616 *
  • 4 4.4245
  • 4.4806
  • 4.8331
  • 5.9983 *

... 6062..*. 4. 1201.*. 4. 3644

  • 4.0820 *

[

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.8025
  • 1.7029
  • 1.8571
  • 1.5165
  • 1.8475
  • 1.6461
  • 1.6022
  • 1.0453 *
    • eeeeeeee.4. 4440..*..4 0749
  • 4.9081
  • 4.0962
  • 4.5972
  • 4.7232
  • 7.2397 *
  • 4.1984
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.4587
  • 1.8539
  • 1.7211
  • 1.8550
  • 1.7018
  • 1.6933
  • 1.4009 *
  • 5.1027
  • 4.0820
  • 4.3970
  • 4.0797
  • 4.4468
  • 4.4693
  • 5.40 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.21..*e 13
  • 1.6204
  • 1.7072
  • 1.6997
  • 1.6547
  • 1.7007
  • 1.5744 *

.8472

  • 4.4496
  • 4.8068
  • 8.7862
  • 4....4524.*.4. 5734 *
  • ee 6702.*.4 4328 *
  • 4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeen.

14

  • 1.6054
  • 1.6558
  • 1.5722
  • 1.6108
  • 1.4116 *

.8718 *

  • 4.7138
  • 4.5705
  • 4.8133
  • 4.6981
  • 5.3611
  • 8.5379
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.3752 + 1.0335
  • 1.2659
  • 1.0507
  • 5.5031
  • 7.2019
  • 5.9780
  • 7.20 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 28.*. M-SUB-Q AT 30% POWER, 4 EFPD, THIS IS LEVEL 13 OF 18 t

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C'

B A

eeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 1.1374
  • 1.7479
  • 1.7543
  • 1.9235
  • 1.5519
  • 1.7232
  • 1.7050
  • 1.4630
  • e 6.6008
  • 4.3929
  • 4.3768
  • 3.9917
  • 4.8379
  • 4.4556
  • 4.5032
  • 5.2483 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9
  • 1.7479
  • 1.4769
  • 1.9589
  • 1.8100
  • 1.9674
  • 1.8057
  • 1.7564
  • 1.0967
  • 5.0834.*. 3. 9197...*.4. 2421.*. 3.9026
  • 4.2522
  • 4.3714..*. 6. 8457..*e
  • 4.3929
  • e**eseeeeeeeeeeeeeeeee l

eeeeeeeeeee.ne..

l 10

  • 1.7543
  • 1.9621
  • 1.8496
  • 1.9813
  • 1.8250
  • 1.8004
  • 1.6654
  • 1.3430
  • e 4.3768
  • 3.9133
  • 4.1512
  • 3.8752
  • 4.2072
  • 4.2648
  • 4.6104
  • 5.7170
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

11

  • 1.9235
  • 1.8143
  • 1.9856
  • 1.6183
  • 1.9760
  • 1.7586
  • 1.7125
  • 1.1117 *
  • 3. 9 917..*. 4. 2 3 21.*.3. 8 6 6 8.* e e 6 3 9 3..*.
3. 8 8 57
  • 4.3 6 61
  • 4. 4 83 5
  • 6. 9 0 67
  • 4 l

ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.5519
  • 1.9792
  • 1.8357
  • 1.9846
  • 1.8207
  • 1.8164
  • 1.4994 *
  • 4.8379
  • 3.8794
  • 4.1827
  • 3.8689
  • 4.2171
  • 4.2271
  • 5.1208
  • j l

eeeeeeeeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 13

  • 1.7232
  • 1.8164
  • 1.8121
  • 1.7682
  • 1.8239
  • 1.6900 *

.9061

  • l
  • 4 l

... 4556.*.4. 2271

  • 4.2371
  • 4.3423
  • 4.2097
  • 4.5432
  • 8.2861
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

l 14

  • 1.7050
  • 1.7618
  • 1.6718
  • 1.7222
  • 1.5112 *

.9318 *

  • 4.5032
  • 4.3581
  • 4.5927
  • 4.4584 * $40809
  • 8.0575
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.4630
  • 1.0967
  • 1.3484
  • 1.1181
  • 6.8670
  • M-8UB-Q
  • 5.2483
  • eeeeeeeeeeeeeeeeeeeeeeen i

k i

F j..

a w

~ _ __

Catawba 2 Cycle 7 Core Operating Limits Report Page 112 of 144 Appendix A 4 ABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP HARGIN) - POWER ESCALATION AT 30% POWER, 4 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTON)

,H Q

F E

D C

B A

      • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8
  • 1.1470
  • 1.7736
  • 1.7746
  • 1.9514
  • 1.5669
  • 1.7447
  • 1.7222
  • 1.4801
  • eeeeeeeeeeeeeeeeeeee. 3577.ee*eee.9630
  • 4.8327
  • 4.4326.*.4 4905
  • 5. 22.48.*

6.6015

  • 4.3603
  • 4..

3 eeeeeeeeeeeeeeeeeee.... eeeeee.

9

  • 1.7736
  • 1.4930
  • 1.9867
  • 1.8293
  • 1.9953
  • 1.8239
  • 1.7779
  • 1.1063 *
  • 4.3603
  • 5.0719
  • 3.8925
  • 4.2276
  • 3.8758
  • 4.2400
  • 4.3498
  • 6.8444
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10
  • 1.7746
  • 1.9899
  • 1.8700
  • 2.0103
  • 1.8453
  • 1.8271
  • 1.6815
  • 1.3580
  • e. 4 3 57 7.. *. 3. 8 8 6 3..
  • e e e.13 5 5
  • 3. 8 4 6 9
  • 4.19 07
  • 4. 2 3 2 5
  • 4. 5 9 91
  • 5. 6 9 4 5. *.

4 e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.9514
  • 1.8346
  • 2.0156
  • 1.6376
  • 2.0060
  • 1.7789
  • 1.7361'* 1.1213 *
  • 3.9630
  • 4.2152
  • 3.8367
  • 4.6241
  • 3.8551
  • 4.3472
  • 4.4544
  • 6.8965
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.5669
  • 2.0071
  • 1.8571
  • 2.0146
  • 1.8432
  • 1.8432
  • 1.5176
  • 87..*.4 1956..*. 4 1956..*. 5. 0957..*
  • 4.8327
  • 3.8531
  • 4.1642
  • 3.83 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1. 7 d 47
  • 1. 8 3 4 6
  • 1. 83 68
  • 1,7 8 9 6
  • 1.8528
  • 1.7147 *

.9157 *

  • 4.4326
  • 4.2152
  • 4.2103
  • 4.3212
  • 4.1738
  • 4.5101
  • 8.2693
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.7222
  • 1.7832
  • 1.6890
  • 1.7457
  • 1.5305 *

.9425

  • e e e e e e e e e e e e e e e.7...*.4 57 87..*.4 42 9 9..*. e e e. 0 52 9
  • 8. 03 43 *
  • 4.4905
  • 4.336 5

eeeeeeeeeeeeee.

15

  • 1. 4 8 01
  • 1.10 53
  • 1. 3 63 4
  • 1.127 8
  • 5.2248
  • 6.8510
  • 5.6722
  • 6.8572
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

AT 30% POWER, 4 EPPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

F E

D C-B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 8

  • 1.1278
  • 1.7522
  • 1.7479
  • 1.9289
  • 1.5412
  • 1.7232
  • 1.6975
  • 1.4608
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. 9551
  • 4.4877
  • 4.5556
  • 5.2937 *
  • 6.7715
  • 4.4136
  • 4.4244
  • 4.0092
  • 4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee, 9
  • 1.7522
  • 1.4683
  • 1.9631
  • 1.8014
  • 1.9728
  • 1.7961
  • 1.7564
  • 1.0881 *
  • 4 4136.*. 5 2009.*. 3. 9393
  • 4.2929
  • 3.9200
  • 4.3057
  • 4.4028
  • 7.0181
  • e..

.seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

10

  • 1.7479
  • 1.9664
  • 1.8400
  • 1.9878
  • 1.8186
  • 1.8068
  • 1.6558
  • 1.3388 *
  • 4 4244
  • 3.9328
  • 4.2029
  • 3. 8904..*eeee.2524 4 eeeeeeeeeeeeeeeeeeeeeeee.5 7765.*.

4.2802

  • 4.6705
  • 4 e..

.eeeeeeeeeeeeeeeeeeee..

11

  • 1.9289
  • 1.8051
  • 1.9942
  • 1.6151
  • 1.9846
  • 1.7532
  • 1.7147
  • 1.1021
  • 4.0092
  • 4.2827
  • 3.8779
  • 4.728.4.*. 3. 8967..*.4 4109.*.4 5.101.*. 7. 0172 *

.ee eeeeeeeeeeeeeeeeeeeeeeeeeee..

)

12

  • 1.5412 8 1.9646
  • 1.6293
  • 1.9931
  • 1.8153
  • 1.8228
  • 1.4962 *
  • 4. 9551..*. 3. 8967..*. 4. 2276..*. 3. 8800
  • 4.2600.*eeee.2425
  • 5.1687
  • 4 e.

eeeeeeeeeens eeeeeeeeeeeeeee 13

  • 1.7232
  • 1.8068
  • 1.8164
  • 1.7629
  • 1.8314
  • 1.6922 *

.9007

  • I

. 4. 4877..*.4. 2802..*.4 2575..*. 4. 3868.*.4 2226..*. 4. 5700.*. 8. 4785..*.

l 14

  • 1.6975 1.7607
  • 1.6633
  • 1.7243
  • 1.5000 *

.9275 *'

  • 4.5556
  • 4.3921
  • 1 eeeeeeeeeeeeeeeeeee.4.6495.*. 4.4849.*.5. 1283
  • 8. 2337..*.

l eeeeee eeeee..

eee..

ee 15

  • 1.4608
  • 1.0881
  • 1.3441
  • 5.2 937
  • 7.0181
  • 5.7 53 5
  • 6.97 65
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

l

\\

Catawba 2 Cycle 7 Core Operating Limits Report Page i13 of 144 Appendix A TABLE 2 (CONTINUSD)

F-SUB-Q & M-SUB-Q VALugs (F-sus-Q OP MARGIN) - POWER ESCALATION AT 30% power, 4 EFPD, THIS 20 LEVEL 10 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) e...H.........G.........F.........B.........D.........C.........B.......A......

1.7222

  • 1.6975
  • 1.4630
  • 8* 1.1224
  • 1.7489
  • 1.7436
  • 1.9267
  • 1.5369 e.. 8612..*.4 4217..*.4 4353.*. 4 0137..*.5. 0108...*.4 4905.*. 4.5556
  • 5.2860 *
  • 6...

.eeeeeeeeeeeeeee.

9

  • 1.7489
  • 1.4641
  • 1.9610
  • 1.7961
  • 1.9717
  • 1.7939
  • 1.7575
  • 1.0871
  • e. 4 4 217.. *. 5. 2 6 01. *. 3. 9. 4 3 6. *. 4 3 0 57.. *. 3. 9 2 21...*. 4 310 8. *. 4 4 0 02.. *.7.

0 8 4 3.

  • 10
  • 1.7436 *.1.9642
  • 1.8357
  • 1.9867
  • 1.8143
  • 1.8068
  • 1.6536
  • 1.3388.*

... 4353.*. 3. 9371.*. 4. 2128... 3. 8925.*.4 2625.*. 4.2002..*. 4. 6766.*. 5 7765.*.

i

  • 4 11
  • 1.9267
  • 1.8014
  • 1.9942
  • 1.6129
  • 1.9835
  • 1.7500
  • 1.7147
  • 1.0988
  • e e. 3. 8779
  • 4.7746
  • 3. 8 9 88 *e e e e e e e e e e e e e.* e e e e e e e e e e e e e e e e e e 4.4190
  • 4.5101
  • 7.037 e..

0137 *e**. 2929

  • 4 4

12

  • 1.5369
  • 1.9835
  • 1.8261
  • 1.9931
  • 1.8121
  • 1.8239
  • 1.4962
  • e.5 0108......3 8988..*eee.2350
  • 3.8800
  • 4.2675.*. 4. 2.400.*.eee.1687
  • 4 5

eeeeeeeeeeeeeeee....

eeeees 13

  • 1.7222
  • 1.8046
  • 1.8164
  • 1.7607
  • 1.0325
  • 1.6943 *

.8996 *

. 4. 4905.*. 4.2.853..*.4 2575..*..4.3921.*.4 2201.*.ee 5643.*. 8. 5602

  • 4....

. ee.

14

  • 1.6975
  • 1.7618
  • 1.6611
  • 1.7254
  • 1.5080 *

.9264 *

  • 4. 5556.*. 4.3895.*.4 6555..*.4.4821..*.5. 1283.*.8 3128
  • e.

.... eeeeee i

15

  • 1.4630
  • 1. 0 871
  • 1. 3 4 3 0
  • 1.10 53

0 8 4 3..*. 5. 7 5 81. *. 6 9 9 6 8.

  • M-SUB-Q AT 30% PCKER, 4 EPPD, THIS IS LEVEL 9 OF 18 I

(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

[

....H.........G.........F.........B.........D.........C......... B.........A......

4

)

8

  • 1.0635
  • 1.6675
  • 1.6558
  • 1.8389
  • 1.4587
  • 1.6440
  • 1.6183
  • 1.3966
  • 3015.*.4.7040
  • 4.7787
  • 5.5371 *
  • 7.2716
  • 4.6375
  • 4 6705
  • 4.2054 *5 ee..eeeeeeeeeeeeeeeeeeeeeeeee eeeeeeeeeeeeeeeeee...

.eeeeeeeeeeee.

9

  • 1.6675
  • 1.3800
  • 1.8721
  • 1.7061
  • 1.8828
  • 1.7061
  • 1.6763
  • 1.0335
  • 1

. 4. 6 3 7 5..*. 5. 5715.. *. 4 13 0 8. *. 4 5 3 27..*. :.*.107 3...* e. 5 3 2 7..*. 4 6 07 9.*.

7. 4 8 2 5
  • 4 2

eeeee.

1.7254

  • 1.5733
  • 1.2756
  • 10
  • 1.6558
  • 1.8753
  • 1.7425
  • 1.8967
  • 1.~...

e.. 67 0 5. *. 4. 12 3 7.. *. 4 4 3 8 0. *. 4. 07 7 2.. *. 4 4 8 21. *. 4. 4 8 21.. *. 4 915 4.. *. 6. 0 6 27.. *.

  • 4 11
  • 1.8389
  • 1.7104
  • 1.9053
  • 1.5337
  • 1.8957
  • 1.6643
  • 1.6365
  • 1.0442 *

. 4. 2054.*. 4. 5214.*.4 0588..*.5 0424

  • 4 0795.*. 4. 6465.*. 4 7256.*.7. 4058..*.

l 12

  • 1.4587
  • 1.8946
  • 1.7361
  • 1.9042
  • 1.7222
  • 1.7404
  • 1.4244
  • 0818.*. 4 4544.*..4 0611..*.4.4905..*.4. 443.5.*. 5. 4291..*.
  • 5.3015
  • 4 5
    • ee 4.

4 eseeeee

    • ee 13
  • 1.6440
  • 1.7168
  • 1.7361
  • 1.6750
  • 1.7500
  • 2.6140 *

.8547

  • e eeeeeeeee.4 5045..*eee.4544
  • 4.6168
  • 4.4190
  • 4.7914
  • 9.0484 *
  • 4.7040
  • 4 e

eee ****eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.6183
  • 1.6825
  • 1.5808
  • 1.6461
  • 1.4362 *

.8793

  • i

... 7787.e**4 5962..*. 4. 6920..*. 4. 6979..*. 5.3845

  • 8.7950 *
  • 4
    • eeeeeeeeeeeeeee 15
  • 1.3966
  • 1.0335
  • 1.2009
  • 1.0496
  • 5 5373..*ee 4825.*.6. 0373..*. 7. 3680..*. M-SUB-Q 7....
  • ee..

Catawbri 2 Cycle 7 Core Operating Limits Report Page 114 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN)~- POWER ESCALATION AT 30% POWER, 4 EFPD, THIS IS LEVEL 8 OF 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 e BOTTON) e...H.........O......... F......... E. e e.... e e....... e e e e e e e. e e e e e e e e e 3. A....

D C

B ee 8

  • 1.0399
  • 1.6354
  • 1.6247
  • 1.8057
  • 1.4309
  • 1.6151
  • 1.5936
  • 1.3784
  • eeeeeeeeeeeeeeee... 4 7598
  • 2 7.. *. 5 4 0 47...*.4 7 8 8 2.*.
4. 8 52 6.*.e' 5. 610 5 *
  • 7.4363
  • 4.7207
  • 4.28

.eeeeeee.......

eeeeeee.-

1.6354'* 1.3602

  • 1.8378
  • 1.6740
  • 1.8496
  • 1.6772
  • 1.6526
  • 1.0174
  • 9
  • e.4 7287...*.5 6856.*. 4 2078...*.4 6197...*.4. 1810.*. 4 6109.*.4 6796.*.7. 6007..*

. ee 10

  • 1.6247
  • 1.8410
  • 1.7093
  • 1.8646
  • 1.6943
  • 1.6975
  • 1.5487
  • 1.2563
  • 598 4

4.5643

  • 4.5556
  • 4.9935
  • 6.1557 *
  • 4 7.eeee*eee.2005
  • 4.5242
  • 4.1474 *
  • ee e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.**eeeeeeeeeeeeeeeeeeee 11

  • 1.8057
  • 1.6793
  • 1.8721
  • 1.5069
  • 1.8625
  • 1.6365
  • 1.6119
  • 1.0260 *
  • 4 4.1308
  • 5.1320
  • 4.1522
  • 4.7256
  • 4.7978
  • 7.5373
  • ee 2827
  • 4.6050
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.4309 *'1.8614
  • 1.7050
  • 1.8721
  • 1.6911.* 1.7136
  • 1.4019 *
        • e 47..*. 4. 1546.*. 4 5356.*.4 1308.*. 4 5729.*. 4 5129.*.5 5162..*

5.40 e........

j 13

  • 1.6151
  • 1.6879
  • 1.7072
  • 1.6461
  • 1.7232
  • 1.5904 *.8397 *.
  • 4 7. 8 8 2...*. 4 5 816..*. 4 52 9 9. *. 4 6 9 7 9. *. 4 4 87 7.*. 4 8 62 4. *. 9 2.10 0. e*

i e..

[

l 14

  • 1.5936
  • 1.6568
  • 1.5551
  • 1.6215
  • 1.4137 *

.8643

  • i
  • .4 8526
  • 4.6675
  • 4.9729.*.4. 7693.*.5. 4702.*. 8 9475..*

e eeeeeeeeeeeeeeeeee.

t 15

  • 1.3784
  • 1.0174
  • 1.2616
  • 1.0324
  • 5 6105..*eeee.6007
  • 6.1296
  • 7. 4903
  • M-SUB-Q-7 eee...

eeeeeeeeeeeeeee.

...e**

i

-AT.

30% POWER, 4 EFFD, THIS IS LEVEL 7 OF 18 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

H Q

F D

b A

e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.E....e e e e e e e e e e e e..C...e e e e e e e e e n..e e e e 8*

.9821

  • 1.5519
  • 1.5401
  • 1.7157 *.1.3570
  • 1.5369
  • 1.5165
  • 1.3141
  • e.7. 8742..*.4 9832
  • 5.0213
  • 4 5073..*. 5. 6990.*.5 0318..*. 5. 0993.*. 5 8848.*e

......seeeeeeeeeeeeee..

9

  • 1.5519
  • 1.2863
  • 1.7466
  • 1.5872
  • 1.7597
  • 1.5936
  • 1.5744 *

.9671

  • ee**eeeeeeeeeeeeee
4. 4271.e*eee.8722
  • 4.3948
  • 4.8526
  • 4.9120
  • 7. 9963..*.
  • 4.9832
  • 6.0122
  • 4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.5401
  • 1.7489
  • 1.5194
  • 1.7746
  • 1.6076
  • 1.6161
  • 1.4716
  • 1.1952 *
  • 5. 0213..*. 4. 4217..*.4. 7756
  • 4. 3577..*. 4. 8106.*. 4 7851..*. 5 2552..*.6. 4701..*.

11

  • 1.7157
  • 1.5915
  • 1.7821 8 1.4298
  • 1.7725
  • 1.5540
  • 1.5347 *.9735
  • 4 4

4.9753

  • 5.0388
  • 7.9435 *
  • 4.5073..*. 4. 8591.e*eeee.3393
  • 5.4087.*aes.3629
  • e ee.

e**eeeeeeeeee seseeeeeeeeeessseseee************

12

  • 1.3570
  • 1.7714
  • 1.6194
  • 1.7811.* 1.6054
  • 1.6322
  • 1.3334 *

. 5 6990..*.4 3656.*. 4. 7756.*. 4 3419..*.4. 8170.*. 4 7380.*. 5. 7997..*.

ee 13

  • 1.5369
  • 1.6044
  • 1.6258
  • 1.5637
  • 1.6408
  • 1.5133 *

.7958

  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.57..*. 4. 713 2.. *. 5 1102.. *.9.

718 2..*.

  • 5.0318
  • 4.8202
  • 4.7567
  • 4.94 14
  • 1.5165
  • 1.5787
  • 1.4780
  • 1.5444
  • 1.3441 *

.8204

  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.74.*.5. 7535
  • 9.4264
  • 4.8987
  • 5.2324
  • 5.00..
  • 5.0993
  • eeeeeeeeeeeee 15
  • 1.3141 *

.9660

  • 1.2006 *

.9800

  • 5.8848
  • 8.0052
  • 6.4413
  • 7.8914
  • M-SUB-Q eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

~

4 I

I t

Catawba 2 Cycle 7 Core Operating Limits Report Page 115 of 144 Appendix A TABLE 2 (CONTINUED)

F-SUB-Q E H-SUD-Q VALUES (F-SUB-Q OP KARGIN) - POWER ESCALATION AT 30% POWER, 4 EFPL, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

G F

E D

C B

A e...H..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8975

  • 1.4266
  • 1.4126
  • 1.5797
  • 1.2445
  • 1.4180
  • 1.3977
  • 1.2124 *

. 8.6165..*. 5 4209..*. 5 4743

  • 4.895.4.*.6. 2140.*. 5. 4537...*.5 5331...*.6 3787..*

l eeeee

... ee.e.ee l

9

  • 1.4266
  • 1.1781
  • 1.6086
  • 1.4555
  • 1.6226
  • 1.4651
  • 1.4533 *

.8889 *

. 5. 4209.*. 6. 5642

  • 4.8074
  • 5.3132
  • 4.7661
  • 5.2783
  • 5.3210
  • 8.6996 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.4126
  • 1.6108
  • 1.4855
  • 1.6365
  • 1.4769
  • 1.4919
  • 1.3537
  • 1.1010 *
  • 5 4743.*. 4. 8010 *.... 2060..*. 4.7256.*. 5. 2362..*. 5. 1835.*.5 7125.*. 7 0240
  • 5 eeeee.

.8932

  • l 11
  • 1.5797
  • 1.4608
  • 1.6440
  • 1.3130
  • 1.6354
  • 1.4287
  • 1.4148 eeeeeeeeeeeeeee.7..*eee.7040
  • 5.8896
  • 4.7287
  • 5.4128.*. 5.4661
  • 8.6579 *
  • 4.8954
  • 5.293 4

i eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

.eeeeeeeeeeeeeee.

I 1.6440

  • 1.4758
  • 1.5048
  • 1.2263 *

.I 12

  • 1.2445
  • 1.6333
  • 1.4876 *

. 6. 2140

  • 4.7349.*. 5. 1985
  • 4 7040.*. 5. 2400.*. 5. 1393..*. 6 3063
  • l

~

1 eee***ee.

...ee..

13

  • 1.4180
  • 1.4748
  • 1.5005
  • 1.4384
  • 1.5133
  • 1.3934 *. 7304
  • eeeeeeeeeeeeeeeee.539
  • 5.3765
  • 5.1102
  • 5. 5501e*10.5875
  • j 5.1..eeeeeeeeeeeeeeeeee*e.
  • 5. 4537
  • 5.2438
  • eeeeeeeeee i

ee 14

  • 1.3977
  • 1.4576
  • 1.3602
  • 1.4244
  • 1.2370 *

.7529

  • j 5.5331
  • 5.3054
  • 5.6856
  • 5.4291
  • 6.2517 *10.2712
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.2124 *

.8879

  • 1.1053 *

.8996

  • 6.3787
  • 8.7101
  • 6.9968
  • 8.5960
  • M-SUB-Q
  • eeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeee.

AT

  • POWER, 4 EFPD, THIS IS LEVEL 5 OF 18 f

(LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

H Q

F E

D

, C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8365

  • 1.3334
  • 1.3216
  • 1.4801
  • 1.1674
  • 1.3323
  • 1.3173
  • 1.1449 *

. 9 2454

  • 5.7997.*. 5.8514..*. 5. 2248
  • 6.6245.*eee.8044
  • 5.8705
  • 6.7546.*

5 l

..eeeeeee.ee eeeee

..ee.eeen e.

e eeeeeeeeee eeeeeeeeeeee I

9

  • 1.3334
  • 1.1010
  • 1.5069
  • 1.3645
  • 1.5230
  • 1.3784
  • 1.3698 *

.8375

  • e. 5. 7 9 9 7..*.7.

0 2. 4 0. *. 5 13 2 0..*. 5. 6 677..*. 5. 07 7 8..*. e e 610 5.*.

5 6 4. 5 5. *e.9.

2 3 3 6..*.

5 10

  • 1.3216
  • 1.5090
  • 1.3912
  • 1.5369
  • 1.3859
  • 1.4019
  • 1.2745
  • 1.0367 *
  • 5.8514
  • 5.1247
  • 5.5586
  • 5.0310
  • 5.5801
  • 5.5162
  • 6.0678
  • 7.4594 *-

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.4801
  • 1.3687
  • 1.5433
  • 1.2327
  • 1.5358
  • 1.3430 *-1.3313 *

.8397

  • 6500
  • 5.0109
  • 6.2734..*.5.0353.*.5. 7581..*. 5. 8091..*eee.2100
  • 9
  • 5.2248
  • 5 *eeeeene****eeeeeee..

e**e..

eeeees

  • eeeeee
    • ee
  • 1.1535
  • 12
  • 1.1674
  • 1.5326
  • 1.3955
  • 1.5433
  • 1.3859
  • 1.4159
  • 6.6245
  • 5.0459
  • 5.5416
  • 5.0109
  • 5.5801
  • 5.4619
  • 6.7044
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3323
  • 1.3869
  • 1.4105
  • 1.3516
  • 1.4244
  • 1.3120 *

.6865 *

  • eeeeee... 5. 5758.*eee.4827
  • 5.7216
  • 5.4291
  • 5.8944 *11.2647 *
  • 5.8044
  • 5

. e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14

  • 1.3173
  • 1.3730
  • 1.2798
  • 1.3409
  • 1.1642 *. 7079
  • e. 5 8 7 0 5.. *. 5. 6 3 2 3. *. 6. 0 4 2. 4. *. 5 7 67 3.. *. 6 6 4 27.. *.10.

9 2 3 8. *.

15

  • 1.1449 *

.8375

  • 1.0410 *

.8450

  • 6.7546
  • 9.2336
  • 7.4287
  • 9.1517
  • eeeeee...eeeeeeeeeeeeeeeeeeeeeeeeeee M-SUB-Q

=

ce--

n,.

~.=

Catawba 2 Cycle 7 Core Operating Limits Report Page i16 of 144 Appendix A TABLE 2 tCONTINUED)

F-SUB-Q & M-SUB-Q VALUES (F-SUB-Q OP MARGIN) - POWER ESCALATION l

AT 30% POWER, 4 EFPD, THIS IS LEVEL '4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

P E

D.

C-B.

A eeeeeeeeeeeeeeeeeeee.*eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 1

8*

.7263

  • 1.1674
  • 1.1545
  • 1.3034
  • 1.0260
  • 1.1835
  • 1.1685
  • 1.0153
  • 10.6186
  • 6.6245
  • 6.6982
  • 5 e e e e e e e e e e e ee e e e e e e e e e e e e e e e ee 9332
  • 7.5372
  • 6.53 45
  • 6.6184
  • 7.6167 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.1674 *

.9607

  • 1.3227
  • 1.1942
  • 1.3409
  • 1.2167
  • 1.2145 *

.7411 *

.. 6. 6245 *. 8. 0498..*. 5.8467..*.6 4759.*.5. 7673..*. 6. 3562.*.6. 3674.*10. 4345.*-

e 10

  • 1.1545
  • 1.3248
  • 1.2177
  • 1.3548
  • 1.2188
  • 1.2391
  • 1.1256 *

.9157 *

  • 6.6982
  • 5.8372
  • 6.3506
  • 5.7080
  • 6.3450
  • 6.2400
  • 6.8703
  • 8.4452 *.

eeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.3034
  • 1.2006
  • 1.3612
  • 1.0839
  • 1.3537
  • 1.1824
  • 1.1760 *

.7390

  • e.5 9332..*.6. 4413..*.5 6811..*. 7. 1350._*. 5 7125
  • 6.5405
  • 6.5762 *10 4647
  • eeeeeeeeeeeeeeeeeeeeeeee
      • eee 12
  • 1.0260
  • 1.3505
  • 1.2274
  • 1.3612
  • 1.2199
  • 1.2509
  • 1.0174 *
  • 7.5372
  • 5.7261
  • 6.3007
  • 5.6811
  • 6.3395
  • 6.1821
  • 7.6007
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeee l

13

  • 1.1835
  • 1.2242
  • 1.2466
  • 1.1899
  • 1.2584
  • 1.1578 *

.6051

  • e. 6 5 3 4 5
  • 6 317 3.. *.6.2 03 3
  • 6. 4 9 9 2..*. 6. 1. 4 52..*.6.

67 9 6..*.12.7 7 9 9..*.

6

...e***e eeeeeeeee...

14

  • 1.1685
  • 1.2177
  • 1.1310
  • 1.1845
  • 1.0260 e

.6233 *

  • 6.6184
  • 6.3506
  • 6.8377
  • 6.5286
  • 7.5372 *12.4066
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 15
  • 1.0153 *

.7401 *

.9200 *

.7433

i eeeeeeeeeeeeeeeeeeeeee.059 *10.4044

  • M-SUB-Q
  • 7.6167 *10.4496
  • 8.4

.eeeeeeeeeeee l

AT 30% POWER, 4 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) i H

G F

E D

C B

A i

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

[

8 *

.6297

  • 1.0046 *

.9950

  • 1.1331 *

.9007

  • 1.0496
  • 1.0399 *

.8986 *

  • 12. 2800
  • 7.6979
  • 7.7725
  • 6.8248 8.5858
  • 7.3600
  • 7.4363.* 8.6063 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

9

  • 1.0046 *

.8322

  • 1.1406
  • 1.0367
  • 1.1738
  • 1.0753
  • 1.0753 *

.5587

  • l
  • 11.7409 *
  • 7.6979
  • 9.2930
  • 6.7800
  • 7.4594
  • 6. 5882..*. 7. 1919
  • 7.1919
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

...eeeeeeeeeeeeeeeeeeeee 10 *

.9950

  • 1.1428
  • 1.0539
  • 1.1792
  • 1.0678
  • 1.0860 *

.9950 *

.8022

  • e.7. 7 7 2 5.. *. 6. 7 67 3.. *. 7. 3 3 81.. *. 6. 5 5 8 3. *. 7. 2 4 2 4. *. 7. 1210.. *. 7. 7 7 2 5. *. 9. 6 4 0 4 *

.e.

11

  • 1.1331
  • 1.0410
  • 1.1845 *

.9489

  • 1.1792
  • 1.0378
  • 1.0324 *

.6469 *

  • 6.8248
  • 7. 4287..*. 6.5286
  • 8. 1497..*. 6.5583.*. 7. 4517..*. 7. 4903..*.11. 9547..*.

i l~

e eeeeee...

j 12 *

.9007

  • 1.1824
  • 1.0753
  • 1.1945
  • 1.0689
  • 1.0956 *

.8954 *

  • 8.5858
  • 6.5405
  • 7.1919
  • 6.5286
  • 7.2351
  • 7.0583
  • 8.6371
  • l eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

13

  • 1.0496
  • 1.0017
  • 1.0935
  • 1.0442
  • 1.1021
  • 1.0185 *

.5355

  • l
7. 0721.*.7. 4058.*.7. 0172..*. 7. 5927..*.14. 4.413..*. -

l

  • 7.3680
  • 7.1492
  • 1 eeeeeeeeeee***ee....

14

  • 1.0399
  • 1.0785 *

.9992

  • 1.0389 *

.9029 *

.5516 *

  • 7.4363
  • 7.1705
  • 7.7392
  • 7.4440
  • 8.5654 *14.0207
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15 *

.8986 *

.6587 *

.8054 *

.6501

. 8. 6 0 6 3. *.11. 7 4 0 9.. *. 9. 6 019.. *.11. 8 9 5 6.. *. M-GUB-Q l

e

.k Catawba 2 Cycle 7 Core Operating Limits Report Page 117 of 144 Appendix A-J TABLE 2 (CONTINUED)

F-SUB-Q E M-SUB-Q VALUES (F-SUB-Q CP MARGIN) - POWER ESCA'.ATION 8

6 1;

AT 30% POWER, 4 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 e BOTTOM) 4 D

C A

.... H......... G....... F......... E....... e e e e e e e e e e e e e e e e e n

  • B
  • eeeeeeeeeeeee.

h.

8 *

.4862 *

.7508 *

.7497 *

.8632 *

.7111 *

.8514 *

.8547 *

.7101

  • d -
  • 15 9045.*10.3005.*10.3152
  • 8.9586 *10.8745
  • 9.0826
  • 9.0484 *10.8909 e........... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9*

.7508 *

.6372 *

.8536 *

.7893 *

.9264 *

.8729 *

.8718 *

.5419

  • 597 8 8706 *14.2701 *
  • 10.3005 *12.1356
  • 9.0598
  • 9.7974
  • 8.3 e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.e.47 6..*.

8 8.e e e e *e e e e.

eeeeeeeeeeeeee.

10 *

.7497 *-.8557 *

.7958 *

.8986 *

.8407 *

.8600 *

.8054 *

.6180 *

  • 10.3152..*.9. 0371.*. 9. 7182.*. 8. 6063.*.9. 1983.*.8 9921.*. 9 6019..*12. 5141.*.

e ee.

11 *

.8632 *

.7936 *

.9029 *

.7433 *

.9211 *

.8236 *

.8140 *

.5055

  • I

... 9586.*. 9. 7445.*. 8. 5654.*.10 4044.*. 8 3961.* 9. 3897..*. 9 5009..*15.2980 *

  • 8

.eeeeeeee.

i

)

12 *

.7111 *

.9328 *

.8472 *

.9264 *

.8375 *

.8632 *

.7122 *

  • 10.8745
  • 8.2901
  • 9.1285
  • 8.3476
  • 9.2336
  • 8.9586 *10.8581.*

eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

i 13 *

.8514 *

.8771 *

.8643 *

.8290 *

.8675 *

.8065 *

.4359 *

. 9. 0 8 2 6. *.8. 816 4.*. 8. 9 47 5. *.9.3 2 9 0..*. 8. 914 4. *. 9 5 8 9 2..+.17.

7 412..

  • l 14 *

.8547 *

.8739 *

.8086

  • 8193 *..7186 *..4487 *
  • 9. 0484
  • 8. 8488
  • 9. 5638
  • 9 4388 *10.7610 *17.2331
  • t d

eeeeeeeeeeeeeeeeeeeeee.

15 *

.7101 *

.5419 *

.6201 *

.5087

  • 10.8909 *14.2701 *12.4709 *15.2014
  • M-SUB-Q a

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee AT 30% POWER, 4 EFPD, THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 e BOTTOM) 4 H

G F

E D

C B

A 3

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1

8*

.2956 *

.2271 *

.4273 *

.2721 *

.4402 *

.5580 *

.5173 *

.3952 *

  • 26 1618..*34 0597. *.18.0969.*28 3163..*.17. 5685.*13. 8592.ee*14. 9496 *19.5682 *

..ee eeee.eeeeeeee.

]

9*

.2271 *

.3781 *

.2656 *

.4616 *

.3117 *

.5184 *

.5398 *

.3299 *

  • 34.0597..*.20. 4551.*29.1156..*.16. 7533..*.24 8133..*14 9187 *14.3267 *23. 4437..*.

j

.**e

...... eeeeeeeeeeeeee 10 *

.4273 *

'.2656 *

.4466 *-.2860 *

.4884 *

.5484 *

.4787 *

.1864 *

  • 18.0969..*.29. 1156.*17. 3157..*.27. 0437..*15.8348.*.14 1028 *16.1536 *41.4980 *

.eeeeeeeeeeeeeeeeeeeen 11 *

.2731 *

.4648 *

.2870 *

.4504 *

.3106 *

.4852

  • 4723 *

.2977

  • 4
  • 28.3163 *16.6375 *26.9427 *16.8707 *24.8988 *15.9396 *16.3734 *25.9736 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeee.

12 *

.4402 *

.3138 *

.4916 *.3117 *

.4809 *

.5066 *

.4091 *

  • 17.5685 *24.6439 *15.7313 *24.8133 *16.0816 *15.2657 *18.9022
  • eeeeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13 *

.5580 *

.5205 *

.5516 *

.4884 *

.5098 *

.4573 *

.2613 *

  • 13. 8592..*.14. 8573..*.14. 0207..*.15. 8348.*.15 1694.*.16 9102..*.29. 5929..*.

14 *

.5173 *

.5409 *..4809 *

.4755 *

.4123 *

.2688 *

  • 14. 9 4 9 6.
  • 14 2 9 8 3. *.16.

0 816..*.16. e. 2 6 27

  • 18.7 5 5 0
  • 2 8.7 67 6
      • ee.

eeeeeeeeeeeeee*eeeeeeeee 15 *

.3952 *

.3299 *

.1864 *

.2999

  • 19.5682 *23.4437 '41.4980 *25.7881
  • M-SUB-Q eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen

+

1 I

l~

Catawba 2 Cycle 7 Core Operating Limits Report Page i18 of 144 -

Appendix A TABLE 3

]

V M-SUB-C VALUES (F-SUB-Q RPS KARGIN) - NORMAL OPERATION THIS IS LEVEL 18'OF 18

)

(LEVEL 18 = TOP OF CORE, LEVEL 1 s BOTTOM)

D C

j

....H.........Ge**ee....F.........E......eeeeee.ee..eeee...ee.Be e e e e e... A......

j 8

  • 5.2035
  • 7.5064
  • 4.1082
  • 6.4743
  • 3.8581
  • 3.3308
  • 3.6012
  • 4.4650
  • l
  • 3.8630
  • 5.2781
  • 3.2926
  • 4.7888
  • 3.2144
  • 2.8516
  • 3.0474
  • 3.8010 *
  • 2.4809
  • 3.2187
  • 2.3939
  • 3.1735
  • 2.4201
  • 2.2527
  • 2.4176
  • 2.9249 *

]

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 7.5064
  • 4.3611
  • 6.6688
  • 3.8148
  • 5.0087
  • 3.5807
  • 3.4415
  • 4.9902
  • 5.2781'* 3.4435
  • 4.8702
  • 3.1605
  • 4.4569
  • 3.0067
  • 2.9531
  • 4.2574
  • 3.1418
  • 2.3386
  • 2.3485
  • 3.3127
  • e.3. 2187..*.2. 4146..*.3. 1641.* 2. 3848 *

.....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

10

  • 4.1082
  • 6.6688
  • 3.9046
  • 6.2528
  • 3.6940 ' 3.3889
  • 3.7918
  • 8.9044 *
  • 3.2926
  • 4.8702
  • 3.1925
  • 4.6890
  • 3.1198 *.2.8882
  • 3.2022
  • 7.0022 *

~

  • 2. 3939..*.3. 1639..*.2. 3618..*. 3. 1544.*. 2. 3757..*. 2. 2490..*. 2. 5154.*. 4 7778..*

e.

11

  • 6.4743
  • 3.7964
  • 6.2403
  • 3.6808
  • 5.7656
  • 3.6555
  • 3.8177
  • 5.4422
  • 4.7888
  • 3.1510
  • 4.6820
  • 3.1062
  • 4.4950
  • 3.1075
  • 3.2518
  • 4.6202 *

. 3. 1735.*. 2. 3848

  • 3. 1.513. *. 2. 3822..*.3. 1448.*. 2. 4047..*.'2. 5222..*. 3. 5237..*. -

12

  • 3.8581
  • 5.7763
  • 3.6811
  • 5.7549
  • 3.5970
  • 3.6052
  • 4.2813
  • j
  • 3.2144
  • 4.4443
  • 3.1136
  • 4.4822
  • 3.0269
  • 3.0386
  • 3.6260 *
  • 2. 4 2 01.*.3. 13 5 6.*.2. 3 7 3 9..*. 3. 14 4 8.
  • e * *. 2 7 61..*. 2. 312 3.*.
2. 7 9 8 5
  • 2 e.

e

...e 13

  • 3.3308
  • 3.5766
  • 3.3416
  • 3.6470
  • 3.5968
  • 3.9388
  • 5.9223 *
  • 2.8516
  • 3.0038
  • 2.8829
  • 3.1014
  • 3.0327
  • 3.3134
  • 4.9098 *-

I

(

  • e s e e e e e e e e e e e e e e e. 2. 247 4.*.
2. 4029
  • 2.3106
  • 2. 5289
  • 3. 5552 *
  • 2.2527
  • 2.3352 +

eeeeeeeeeeeeen.

eeeeeeeeeeeeene 14

  • 3.6012
  • 3.4415
  • 3.7827
  • 3.8084
  • 4.2639
  • 5.7982 *
  • 3.0474
  • 2.9531
  • 3.1957
  • 3.2451
  • 3.6177
  • 4.8318 *
  • 2. 4176.*. 2. 3485.*. 2. 5148.*. 2. 5222..*.2. 7944.*.3. 5236.*.-

15

  • 4.4650
  • 4.9902
  • 8.8790
  • 5.4234
  • 3.8010
  • 4. 2 57 4
  • 7. 0 02 2
  • 4. 613 5
  • 15 0 EFPD 118 % POWER -
  • 2.9249
  • 3.3127
  • 4.7754
  • 3.5237
  • 415 EFPD 118 % POWER I

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON)

H G

F E.

D C.

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8* 3.6853

  • 2.7332
  • 2.7910
  • 2.4605
  • 2.7252
  • 2.4802
  • 2.4579
  • 2.8073 *
  • 2.7825
  • 2.1642
  • 2.2556
  • 2.0316
  • 2.2700
  • 2.1319
  • 2.1509
  • 2.5008 *
  • 2.0010
  • 1.6370
  • 1.7950
  • 1.6564
  • 1.8700
  • 1.7754
  • 1.8988
  • 2.1755
  • seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeee*

9

  • 2.7332
  • 3.0080
  • 2.5184
  • 2.6658
  • 2.3226
  • 2.4164
  • 2.4297
  • 3.4012 *
  • 2.1642
  • 2.3856
  • 2.0622
  • 2.2066
  • 1.9805
  • 2.0937
  • 2.1190
  • 3.0380
  • e.1. 6370..*.1. 8469
  • 1. 6394.*. 1. 8031..'*. 1 6616.*.1 8170.*. 1. 8465.*.2. 6288.*.

e**e..

10

  • 2.7910
  • 2.5143
  • 2.6368
  • 2.3868
  • 2.5148
  • 2.5041
  • 2.5494
  • 3.0922 *
  • 2.2556
  • 2.0595
  • 2.1701
  • 2.0006
  • 2.1348
  • 2.1276
  • 2.2237
  • 2.7140
  • i
  • 1. 7 9 5 0. *. 1. 6 3 9 4. *. 1. 7 7 0 0. *. 1. 6 3 9 3.. *. 1. 813 5.. *. 1. 7 871. *.1 9 5 01. *.2.

2 6 47.. *e e.

11

  • 2.4605
  • 2.6568
  • 2.3832
  • 2.6773.* 2.3278
  • 2.5269
  • 2.5245
  • 3.6512 *

'* 2.0316

  • 2.2004
  • 1.9981
  • 3.2465
  • 1.9968
  • 2.1821
  • 2.2363
  • 3.2418
  • l e.1. 6564.*. 1. 8031
  • 1.6393
  • 1.8579
  • 1. 6493..*. 1. 8807..*. 1. 9302..*. 2e.7536 *

..eeeeeeeeeeeeeeeeeeeeeee eeeee.

12 + 2.7252

  • 2.3140
  • 2.5068
  • 2.3226
  • 2.4598
  • 2.4547
  • 2.7934 *
  • 2.2700
  • 1.9743
  • 2.1291
  • 1.9930
  • 2.1392
  • 2.1363
  • 2.4889 *
  • 1. 8700.*. 1. 6573..*.1. 8115..*.1. 6487
  • 1.8115
  • 1.8039
  • 2.1675 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 2.4802
  • 2.4109
  • 2.5001
  • 2.5208
  • 2.4489
  • 2.5494
  • 4.0265 *
  • 2.1319
  • 2.0881
  • 2.1205
  • 2.1776
  • 2.1319
  • 2.2637
  • 3.4829 *
  • 1 7754.*. 1.8142
  • 1.7855
  • 1.8788..*. 1 8018..*.1. 9701.*. 2. 8187..*e e..

eeeeeeeeeeeeeeeeeeeee 14

  • 2.4579
  • 2.4260
  • 2.5432
  • 2.5163
  • 2.7811
  • 3.9329 *
  • 2.1509
  • 2.1176
  • 2.2206
  • 2.2316
  • 2.4811
  • 3.4241 *

. 1. 8988..*. 1 8465.*. 1. 9501.*. 1. 9291.*. 2. 1646.*. 2. 7962..*.

15

  • 2.8073
  • 3.4050
  • 3.0860
  • 3.6428
  • 2.5000 3.0410
  • 2.7117
  • 3.2351
  • 150 EFPD 118 % POWER i
  • 415 BFPD 118 % POWER
  • 2. 1755..*.2. 6288..*. 2. 2647..*.2. 7536 e.

1

)

i i

Catawba 2 Cycle 7 Core Operating Limits Report Page 119ef144 Appendix A -

TABLE 3 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORMAL OPERATION THIS IS LEVEL 16 OF 18 (LEVEL 18 s TOP OF CORE, LEVEL 1 m BOTTOM) e e e e e e e e e e e e e e e e e e e e e e e e e e.....E... e e....D.........C.........Beeeee....A....

H 0

F 8* 3.0080

  • 2.1506
  • 2.2050
  • 1.9644
  • 2.2649
  • 2.0899
  • 2.0937
  • 2.3243
  • I
  • 2.3652
  • 1.7653
  • 1.8535
  • 1.6761
  • 1.9315
  • 1.8006
  • 1.8812
  • 2.1435 *
  • 1. 8 418. *. 1. e. 47 0 6. *.1.

6 0 8 0. *. 1. 47 87...*.1.

712 2.. *. 1. 5 9 9 6. e *. 1 7 6 51.

  • e. 9 916.. *.

1 i

..e e

.ee.

.. e 9

  • 2.1506
  • 2.4198
  • 1.9794
  • 2.1291
  • 1.9124
  • 2.0368
  • 2.0378'* 2.9298
  • l
  • 1.7653
  • 1.9948
  • 1.6814
  • 1.8246
  • 1.6716
  • 1.7975
  • 1.8172
  • 2.7106 *
  • 1. 4706.*.1 6823
  • 1 4631
  • 1.6157..*.eee.4896
  • 1.6673..*..1..,6906
  • 2. 4863.*.

1 i

.. ee.....

ee...

.eeeeee..

eeeeeeeeee.

..eeee.

j 10

  • 2.2050
  • 1.9781
  • 2.0881
  • 1.9077 *'2.0649
  • 2.0500
  • 2.1450
  • 2.5122 *
  • 1.8535
  • 1.6796
  • 1.7893
  • 1.6549
  • 1.8109
  • 1.7873
  • 1.9237
  • 2.2950
  • l
  • 1. 60.80..*.1. 4631..*. 1 5870..* 1. 4677..*.1. 6387.*.1. 6116 *. 1. 8042..*. 2. 0630.*

.e 11

  • 1.9644
  • 2.1219
  • 1.9042
  • 2.1963
  • 1.8949
  • 2.0965
  • 2.0759
  • 3.0182 *

.I 1.6761

  • 1.8203
  • 1.6541
  • 1.9061
  • 1.6549
  • 1.8609
  • 1.9039
  • 2.7934
  • j
  • 1.4787..*. 1 6157..*. 1. 4677..*.1.7026
  • 1.4899
  • 1.7286
  • 1.7668
  • 2.5439
  • I eeeeee.

. ee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12

  • 2.2649
  • 1.9042
  • 2.0581
  • 1.8949
  • 2.0251
  • 2.0101
  • 2.3341 *
  • 1.9315
  • 1.6663
  • 1.0047
  • 1.6523
  • 1.8182
  • 1.8141
  • 2.1671
  • eeeeeeeeeeeeeen.4.*ee 6370.*eeee.4892
  • 1.6741.* 1.6617
  • 2.0215 *
  • 1.7122
  • 1.486 1

1 s

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 2.0899
  • 2.0316
  • 2.0526
  • 2.0895
  • 2.0049
  • 2.1148
  • 3.4789 *
  • 1.8006
  • 1.7924
  • 1.7812
  • 1.8645
  • 1.8099
  • 1.9632 *.3.1285
  • e.1. 5996.*. 1. 6655..*. 1. 6102...*.1 7270
  • 1.6600
  • 1.8436
  • 2.6979..*e eeeeeeeeeeeeeeeeeeeeeeeeee..

14

  • 2.0937
  • 2.0351
  • 2.1392
  • 2.0690
  • 2.3220
  • 3.3936 *
  • 1.8812
  • 1.8161
  • 1.9213
  • 1.9005
  • 2.1597
  • 3.0748 *
  • 1.7651
  • 1.6900
  • 1.8042
  • 1.7661
  • 2.0180
  • 2.6750
  • e**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 2.3243
  • 2.9326
  • 2.5062
  • 3.0067
  • 2.1435
  • 2.7131
  • 2.2916
  • 2.7885
  • 150 EFPD 118 % POWER e 1.9916
  • 2.4856
  • 2.0630
  • 2.5445.* 415 EFPD 118 % POWER-eeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

THIS IS LEVEL 15 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F B

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeeeeeeeeeeeee......een 8

  • 2.7301
  • 1.9159
  • 1.9681 *'1.75k1
  • 2.0638 a'1.9077
  • 1.9190
  • 2.1227
  • j 2.2106
  • 1.6159
  • 1.7032
  • 1.5416
  • 1.8066
  • 1.6743
  • 1.7762
  • 2.0290
  • l 1.8245
  • 1.4447
  • 1.5808 *-1.4470
  • 1.7010
  • 1.5764
  • 1.7566
  • 1.9758 *
                        • eseesessesseseessaansasseeeeee**eeeeeeeeeeeseeeeeeeeeeeee***e.

l 9

  • 1.9159
  • 2.1805
  • 1.7587
  • 1.9097
  • 1.7255
  • 1.8579
  • 1.8542.* 2.7131 *
  • 1.6159
  • 1.8527
  • 1.5363
  • 1.6814
  • 1.5363
  • 1.6832
  • 1.6995
  • 2.5995
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeee. 1. 4640..+..1. 6548.*. 1. 6733
  • 2.4944.*.

I

  • 1.4447
  • 1.6679
  • 1.4310
  • 1.5891
  • L ee eeeeeeeeee..

I 10

  • 1.9681
  • 1.7567
  • 1.8678
  • 1.7075
  • 1.8678
  • 1.8553
  • 1.9596
  • 2.2834 *
  • 1.7032
  • 1.5348
  • 1.6497
  • 1.5186
  • 1.6779
  • 1.6558
  • 1.8141
  • 2.1642 *
  • 1.5808
  • 1.4310
  • 1.5649-* 1.4417
  • 1.6193
  • 1.5862
  • 1.7977
  • 2.0460
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.7597
  • 1.9028
  • 1.7047
  • 1.9961
  • 1.7028
  • 1.9016
  • 1.8800
  • 2.7616 *
1. 5416
  • 1. 67 9 G
  • 1. 518 6
  • 1.7 812
  • 1. 5 2 67
  • 1.7 50 6
  • 1.7 853
  • 2. 6 591 *

. 1. 4. 47 0. *. 1. e. 5 8 91.. *.1 4 417.. *. 1. 6 913.. *. 1. 4 6 8 6. *.1.

719 5. *. 1 7 5 2 3. *. 2. 5 418

  • s.....

.eeen 12

  • 2.0638
  • 1.7179
  • 1.8601
  • 1.7028
  • 1.8373
  • 1.8152
  • 2.1319 *
  • 1.8066
  • 1.5318
  • 1.6725
  • 1.5237
  • 1.7042
  • 1.6950
  • 2.0595 *
  • 1. 7010.*.1 4609..*.1. 6171...*.1. 4679..*. 1 6700..*.1. 6548.*. 2. 02.41..*.

13

  • 1.9077
  • l'8503
  • 1.8487
  • 1.8948
  • 1.8089
  • 1.9249
  • 3.2349
  • I
  • 1.6743
  • 1.6787
  • 1.6506
  • 1.7457
  • 1.6914
  • 1.8612
  • 3.0199
  • l
  • 1.5764
  • 1.6530
  • 1.585..1.*.1. 7179..*. 1. 6527..*. 1. 8483..*. 2. 7408
  • eeeeeeeeeeeeeeeeeeeeeeee.

e**.

14

  • 1.9190
  • 1.8509
  • 1.9547
  • 1.8721
  • 2.1205
  • 3.1512 *
  • 1.7762
  • 1.6977
  • 1.8109
  • 1.7812
  • 2.0514
  • 2.9669 *
  • e e 7 5 6 6. *.1.67 3 2. *.1.7 9 7 0
  • 1. 7 5 2 3.*.2.

0215.. *.2.718 0. *.

1....

eee**eeeee...

15

  • 2.1227
  • 2.7155
  • 2.2783
  • 2.7520
  • 4 BFPD 118 % POWER
  • 2.0290
  • 2.6017
  • 2.1612
  • 2.6546
  • 150 EFPD 118 % POWER 2

415 EFPD 118 % POWER e.. 9758 *...... 4944

  • 2.0469..*. 2. 5439..*
  • 1 eeeeeeeeen..

.ee l

['

h-

a 4

Catawba 2 Cycle 7 Core Operating Limits Report Page 120of144 Appendix A j

. 1 TABLE 3 (CONTINUED)

(

)

M-SUB-C VALUES (F-SUB+Q RPS KARGIN) - NORKAL OPERATION J.

' THIS IS LEVEL 14 OF 18 i -

(LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

.... H......... G......... F......... E.. e e..... D......... C....... e e e e e e e e e.. A......

B j.

8

  • 2.7082
  • 1.8766
  • 1.9343
  • 1.7274
  • 2.0471
  • 1.8846
  • 1.9051
  • 2.1069 *
  • 2.2532
  • 1.6242
  • 1.7172
  • 1.5507
  • 1.8404
  • 1.6941
  • 1.8172
  • 2.0826
  • j
  • 1. 9370.*.1 5256.*.1. 6714.*.1 5191'* 1.8044
  • 1.6610 *.1.8524
  • 2.0758
  • e.

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

}'

9

  • 1.8766
  • 2.1543
  • 1.7207
  • 1.8812
  • 1.6972
  • 1.8395
  • 1.8313
  • 2.7155 *
  • -1.6242
  • 1.8814
  • 1.5401
  • 1.6968
  • 1.5439
  • 1.7125
  • 1.7276
  • 2.6867 *
  • 1.5256
  • 1.7695
  • 1.5090
  • 1.6807
  • 1.5447
  • 1.7530
  • 1.7671
  • 2.6355
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee d

10

  • 1.9343
  • 1.7179
  • 1.8395
  • 1.6753
  • 1.8427
  • 1.8237
  • 1.9451
  • 2.2650
  • 1.7172
  • 1.5386
  • 1.6663
  • 1.5259
  • 1.6968
  • 1.6716.* 1.8568
  • 2.2221
  • 1

. 1. 6714.*.1. 5090..*.1 6571..*. 1. 5228.*. 1. 7139

  • 1.6738
  • 1.9076
  • 2 1716..*

J e**e

..eeeeeeeeeeeeeeeeeeee.e s-I 11

  • 1.727 4
  • 1.87 45
  • 1.6717
  • 1.97 54
  • 1.6735 * ^ 1.8801
  • 1.8564
  • 2.7 544
  • i
  • 1.5507
  • 1.6941
  • 1.5257
  • 1.8130
  • 1.5386
  • 1.7833
  • 1.8246
  • 2.7448 *

' '.1. 5191.. *.1.6 8 07.. *.1 52 2 3.. *.1.

7 9 82. e *.1.

5 5 2 8.. *. 1 8 2 41.. *.1.

8 5 5 6.. *.2.

7102. * -

4 eee e

e.

12

  • 2.0471
  • 1.6880
  • 1.0352
  • 1.6700
  • 1.8182
  • 1.7870
  • 2.1176 *
  • 1.8404
  • 1.5386
  • 1.6914
  • 1.5356
  • 1.7390
  • 1.7256
  • 2.1190 *
  • 1. 8044..*.1. 5406..*. 1. 7120..*.1. 5520.*. 1. 7754.*.1. 7543.*. 2. 1572..*.

f 13

  • 1.8846
  • 1.8309
  • 1.8173
  • 1.8734
  • 1.7809
  • 1.9074
  • 3.2418 *
  • 1.6941
  • 1.7060
  • 1.6654
  • 1.7782
  • 1.7209
  • 1.9132
  • 3.1382 *
  • 1. 6610..*. 1. 7514.*. 1 6729.*. 1 8230.*. 1. 7524.*.1 9672..*.2. 9.451.*.

i 14

  • 1.9051
  • 1.8280
  • 1.9403
  • 1.8487 *'2.1049
  • 3.1577 *
  • 1.8172
  • 1.7256
  • 1.8535
  • 1.8193
  • 2.1105
  • 3.0810 *

'i

  • 1.8524
  • 1.7673
  • 1.9076
  • 1.8556
  • 2.1542
  • 2.9206
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 15
  • 2.1069
  • 2.7179
  • 2.2601
  • 2.7424 *. 4 EFPD 118 % POWER
  • 2.0826
  • 2.6867
  • 2.2190
  • 2.7400
  • 150 EFPD 118 % POWER j
  • 2.0758..*.2. 6378.*.2. 1716.*. 2. 7110..*. 415 EFPD 118 % POWER 4

s

...e**

3 l

THIS Z8 LEVEL 13 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) j.

F E

D C

B A

e...H.........G. e *

  • e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.

eeeeeeee.

8

  • 2.6679
  • 1.8356
  • 1.8891
  • 1.6899
  • 2.0093
  • 1.8465
  • 1.8667
  • 2.0621 *-
  • 2.2853
  • 1.6343
  • 1.7275
  • 1.5599 8 1.8618
  • 1.7097
  • 1.8416
  • 2.1134 *
  • 2.0253 + 1.5795
  • 1.7200
  • 1.5507
  • ese****eeee*****eeeeeeeeeeeeeee***ee. 1 8561
  • 1.7042
  • 1.9005
  • 2.1291
  • l

. **eeeeeeeeeeeeeeeeeeeeeeeeeeessee I

9

  • 1.8356
  • 2.1125
  • 1.6798
  • 1.8395
  • 1.6592
  • 1.8016 * '1.7922
  • 2.6702 *
  • 1.6343
  • 1.9013
  • 1.5461
  • 1.7097
  • 1.5515
  • 1.7313
  • 1.7457
  • 2.7375
  • 1.8026
  • 1.8047
  • 2.7082
  • e 1.5795
  • 1.8338
  • 1.5499
  • 1.7285
  • 1.5850
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee a

10

  • 1.8891
  • 1.6771
  • 1.7985
  • 1.6373
  • 1.8026
  • 1.7829
  • 1.9074'* 2.2213 *

]

  • 1.7275
  • 1.5446
  • 1.6796
  • 1.5348
  • 1.7116
  • 1.6841
  • 1.8823
  • 2.2572 *
  • 1.7200
  • 1.5..4 9 9.. *. 1. 7 0. 9 7.. *.1.

5 6 07.. *. 1. 7 7 0 2.. *.1 7 219.. *. 1. 9 6 57.. *.2 e. 2 2 0 6

  • eeeee.
  • eeeeeeeeeeee.

11

  • 1.6899
  • 1.8330
  • 1.6330
  • 1.9364
  • 1.6373
  • 1.8395
  • 1.8152
  • 2.7094
  • 1
  • 1.5599
  • 1.7069
  • 1.5356
  • 1.8349
  • 1.5499,* 1.8047
  • 1.8470
  • 2.8009
  • 4-
  • 1. 5 5 07.. *. 1. 7 2 8 5. *.1.

5 5 9 9.. *.1.

8 6 9 8.* e * *. 6151

  • 1. 9 0 6 2
  • 1. 9 213
  • 2.7 9 5 9
  • 1 i
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeese l'2
  • 2.0093
  • 1.6504
  • 1.7944
  • 1.6330
  • 1.7802
  • 1.7459
  • 2.0758 *
  • 1.8618
  • 1.5461
  • 1.7051'* 1.5469
  • 1.7623
  • 1.7438
  • 2.1553
  • l

. 1. 8 5 61. *. 1. 5 8 02.. *.1.

7 6 82.. *.1.614 3.. *. 1. 8 6 0 4. *. e e e. 8 2 8 3

  • 2. 2 5 5 0
  • 1 eeeeeeeeeeeeee.

13

  • 1.8465
  • 1.7934
  • 1.7768
  • 1.8320
  • 1.7390
  • 1.8656
  • 3.1942 *
  • 1.7097
  • 1.7256
  • 1.6770
  • 1.7995
  • 1.7390
  • 1.9439
  • 3.2043
  • a
  • 1. 7042.*. 1. 8006.*. 1. 7209..*. 1. 9051..*.1. 8266.*. 2. 0554.*.3. 0843..*.

e.

14

  • 1.8667
  • 1.7891
  • 1.9016
  • 1.8068
  • 2.0622
  • 3.1093
  • 1.8416
  • 1.7438
  • 1.8790
  • 1.8427 *'2.1479
  • 3.1447
  • e.1. 9005..+. 1. 8057..*.1. 9657..*.1. 9213
  • 2.2523
  • 3.0566 *

.. eeeeeeeeeeeeeeeeeeee.

15

  • 2.0621
  • 2.6726
  • 2.2150
  • 2.6978
  • 4 EFPD 118 % POWER'
  • 2.1134
  • 2.7399
  • 2.2539
  • 2.7959
  • 150 EFPD 118 % POWER

'. 2.1291

  • 2.7082
  • 2.2221
  • 2.7984
  • 415 EFPD 118 % POWER 4

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee a

s 5

-r w

r 9

-x'--

. ~ -

i i

Catawha 2 Cycle 7 Core Operating Limits Report Page 121 of 144 Appendix A f

2 TABLE 3 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORMAL OPERATION i

THIS IS LEVEL 12 OF 18 -

(LEVEL 18 = TOP OF CORE, LEV 1th 1 m BOTTOM)

....H....eeee.Ge e e e e e. e..... e e.. E......... D........ C........ B......... A. e e.. e F

8

  • 2.7623
  • 1.8859
  • 1.9451
  • 1.7361
  • 2.0750
  • 1.8961 a 1.9213
  • 2.1198 *
  • 2.4352
  • 1.7294
  • 1.8330
  • 1.6489
  • 1.9818
  • 1.8120
  • 1.9571
  • 2.2459 *
  • 2.2751
  • e.2. 1805.*.1. 6806
  • 1.8470
  • 1.6532
  • 1.9987
  • 1.8246
  • 2.0368 seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 9
  • 1.8869
  • 2.1805
  • 1.7236
  • 1.8948
  • 1.7047
  • 1.8568
  • 1.0421
  • 2.7573
  • 1.6352
  • 1.8151
  • 1.6420
  • 1.8405
  • 1.8503
  • 2.9185 *
  • 1.7294
  • 2.0226
  • eeeeeeeeeeeeeeeeeeeeeeeeee. 1. 8557.e*eee.6877
  • 1.9319
  • 1.9272
  • 2.9019.*
  • 1.6886
  • 1.9728
  • 1.6515
  • 1 e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.9451
  • 1.7217
  • 1.8535
  • 1.6825
  • 1.8579
  • 1.8334
  • 1.9657
  • 2.2867 *
  • 1.8330
  • 1.6343
  • 1.7843
  • 1.6259
  • 1.8182
  • 1.7833
  • 2.0045
  • 2.3999
  • f
  • 1.8470
  • 1.6515
  • 1.8352
  • 1.6610
  • 1.8936
  • 1.8309
  • 2.0993
  • 2.3692
  • eeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11 a 1.7361 e 1.8800

  • 1.6780
  • 1.9987
  • 1.6834
  • 1.8971
  • 1.8676
  • 2.0034
  • 1.9225
  • 1.9645
  • 2.9896 *
  • 1.6489
  • 1.8130
  • 1.6259
  • 1.9538
  • 1.6429 e.1. 6532
  • 1.8557
  • 1.6602
  • 2.0027
  • 1.7162
  • 2.0238.*eee.0395
  • 2.9755
  • 2

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

eeeeeeeeeeeeeen 12

  • 2.0750
  • 1.6954
  • 1.8492
  • 1.6780
  • 1.8363
  • 1.7953
  • 2.1435 *
  • 1.9818
  • 1.6360
  • 1.8120
  • 1.6394
  • 1.8790
  • 1.8546
  • 2.3017
  • 4 I

eeeeeeeeeeeeeeeeeeeeeeeeeeee.1 7153.*e1.9818

  • 1.9427
  • 2.3907..*.
  • 1.9987 a 1.6841
  • 1.8914 *

.. e eeeeeeeeeeeeeeeeeeeeee.

l 13

  • 1.8961
  • 1.8481
  • 1.8259
  • 1.8891
  • 1.7881
  • 1.9237
  • 3.3123 *
  • 1.8120
  • 1.8341
  • 1.7772
  • 1.9167
  • 1.8492
  • 2.0744
  • 3.4280
  • j
  • 1. 8246..*. 1. 9296..*. 1. 8309..*. 2. 0225.*eee.9403
  • 2.1882
  • 3.2909
  • 1 e.

.. e eeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.9213
  • 1.8378
  • 1.9596
  • 1.8598
  • 2.1305
  • 3.2246 *
  • 1.9571
  • 1.8481
  • 2.0006
  • 1.9596
  • 2.2916
  • 3.3673
  • e.2. 03 6 8.. *. 1 9 27 2..*. 2. 0 9 9 3.. *. 2. 0 3 9 5. *.2.

3 8 8 9. *.3.2 5 9 2..

  • i 15
  • 2.1198
  • 2.7598
  • 2.2817
  • 2.7910
  • 4 EFPD 118 % POWER i
  • 2.2459
  • 2.9185
  • 2.3980
  • 2.9839
  • 150 EFPD 118 % POWER 415 EFPD 118 % POWER 4 6.. *. 2. 3 6 9 2.. *.2.

9 7 8 3.. *e j

  • 2.2751
  • 2.90 1

eeeeeeeeeeeeee.

THIS IS LEVEL 11 OF 18

'I 1

{LNVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

I H

O F

E D

'C B

A 1

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 2.8556
  • 1.9669
  • 2.0342
  • 1.8009
  • 2.1728
  • 1.9744
  • 2.0032
  • 2.2009 *
2. 63 3 3
  • 1. 8 6 01
  • 1. 97 8 0
  • 1. 77 3 J
  • 2.1422 *
1. 9 4 9 9
  • 2.1077
  • 2. 4 07 2 *
  • 2.0070
  • 2.2348
  • 2.4811
  • eeeeeeeeeeeeee
    • ee.2. 0448 *..... 1. 8214e**2.2139
  • 2.4217
  • 1.8645 *

. * **eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 9

  • 1.9669
  • 2.2836
  • 1.7963
  • 1.9843
  • 1.7768
  • 1.9415
  • 1.9183
  • 2.8772 *

)-

,* 1.8601

  • 2.1868
  • 1.7594
  • 1.9620
  • 1.7663
  • 1.9868
  • 1.9893
  • 3.1382
  • eeeeeeeeeeeeeeeeeeeeee.193.e*eeee.0541
  • 1.8535
  • 2.1276
  • 2.1119
  • 3.1775 *
  • 1.8645
  • 2.1900
  • 1.8 2

4 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee j

4 10

  • 2.0342
  • 1.7943
  • 1.9427
  • 1.7557
  • 1.9463
  • 1.9136
  • 2.0568
  • 2.3868
  • 1.9780
  • 1.7584
  • 1.9296
  • 1.7515
  • 1.9645
  • 1.9190
  • 2.1627
  • 2.5807
  • i e 2.0440
  • 1.8193
  • 2.0316 *eeeeeeeeeeeeeeeeeeeeeeeee 1. 8267
  • 2.0881
  • 2.0070
  • 2.3017
  • 2.5892 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 1

11

  • 1.8089
  • 1.9768
  • 1.7508
  • 2.0950
  • 1.7567
  • 1.9893
  • 1.9508
  • 2.9394
  • 1.7732
  • 1.9596
  • 1.7515
  • 2.1154
  • 1.7702
  • 2.0799
  • 2.1176
  • 3.2285
  • j eeee***

.. 2. 0555.*. 1. 8267..*. 2. 2122..*.1. 8801..*. 2. 2159

  • 2. 2237.
  • 3. 2485..*.
  • 1.8214
  • a ee..

12

  • 2.1728
  • 1.7667
  • 1.9367
  • 1.7508
  • 1.9284
  • 1.8789
  • 2.2491
  • 2
  • 2.1422
  • 1.7603
  • 1.9571
  • 1.7663
  • 2.0355
  • 2.0032
  • 2.4889 *
  • 2. 213 9
  • 1. 8 503
  • 2. 0 8 68. *.1. 87 9 0..*e e e e.16 86
  • 2.1105
  • 2. 6 02 0
  • 2 4

eeeeeeeeeeeeeeeeeeeeeeee...

eeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.9744
  • 1.9331
  • 1.9054.* 1.9818
  • 1.8721
  • 2.0186
  • 3.4869 *-

1.9499

  • 1.9793
  • 1.9120
  • 2.0730
  • 1.9968
  • 2.2443
  • 3.7168
  • e.. 0 07 0.. *. 2. e.12 4 8
  • 2. 0 0 57 *. 2. 215 9.. *.2.

10 91.*. 2. 3 7 6 3. *. 3. 57 2 8. *.

2 eeeeeeeeee**e 14

  • 2.0032
  • 1.9148
  • 2.0514
  • 1.9423
  • 2.2348
  • 3.3936 *
  • 2.1077
  • 1.9000
  • 2.1582
  • 2.1119
  • 2.4792
  • 3.6499
  • eeeee.48..*.2. 1119.*.2 3017..*. 2. 2237e**2 5977
  • 3.5396
  • 2.23 e *. eeeeeeeeeeee 15
  • 2.2009
  • 2.87b9
  • 2.3813
  • 2.9284
  • 2.4072
  • 3.1414
  • 2.5786
  • 3.2252
  • 150 BFPD 118 % POWER

. 2. 4811.*.3 1775..*.2. 5892..*. 3 2518.

  • 415 BFPD 118 % POWER e

o

- - -, +

Catavta 2 Cycle 7 Core Operating Limits Report Page 122 0f 144 Appendix A TABLE 3 (CONTINUED) i M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORMAL OPERATION l

(

THIS IS LEVEL 10 OF 18 j

(LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTON)

H O

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8

  • 2.8290
  • 1.9582
  • 2.0212
  • 1.7994
  • 2.1620
  • 1.9781
  • 2.0109
  • 2.2245 *
  • 2.7325
  • 1.9596
  • 2.0881
  • 1.8667
  • 2.2616
  • 2.0488
  • 2.2001
  • 2.5128
  • 2.4127
  • 2.6591
  • e.2. 6493
  • 2.0382..* 2.2427
  • 1.9818
  • 2.4178
  • 2.1716 0

...ee...

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 9

  • 1.9582
  • 2.2717
  • 1.7860
  • 1.9731
  • 1.7728
  • 1.9427
  • 1.9266
  • 2.9130 *
  • 1.9596
  • 2.3113
  • 1.8535
  • 2.0717
  • 1.8590
  • 2.0909
  • 2.0854
  • 3.2873
  • l e. 2. 0 3 0 2.. *. 2. 4 02 6. *.1.

9 8 3 0. *.2.2 5 07.. *. 2. 0.121. *. 2. 3118. *. 2. e. 2 7 51

  • 3 412 6.. *e l

l ee..eeee e 1.7508

  • 1.9463
  • 1.9171
  • 2.0730
  • 2.4222
  • l 10
  • 2.0212
  • 1.7840
  • 1.9319
  • 2.0881
  • 1.8514
  • 2.0382
  • 1.8459
  • 2.0744
  • 2.0173
  • 2.2735
  • 2.7001 *

{

e.. 2427eeeee.1.9830..*. 2 2284.*.1 9880.*.2. 278.4.*.2. 1731.* 2 4831.*ee. 7713..*

2

  • 2 ee.

e

. ee. e...

11

  • 1.7994
  • 1.9669
  • 1.7459
  • 2.0864
  • 1.7518
  • 2.0019
  • 1.9719
  • 2.9981
  • l
  • 1.8667
  • 2.0689
  • 1.8459
  • 2.2366
  • 1.8656
  • 2.1943
  • 2.2253
  • 3.3918 *

. 1. 9818..*. 2. 2507..*. 1. 9880

  • 2.4217..*ee. 0461.*.2. 4072..*. 2. 3944
  • 3.4856
  • 2

...eeeeee eeeeeeeeeeeeee.

12

  • 2.1620
  • 1.7627
  • 1.9367
  • 1.7468
  • 1.9427
  • 1.8938
  • 2.2767 *
  • 2.2616
  • 1.8524
  • 2.0662
  • 1.8612
  • 2.1538
  • 2.1105
  • 2.6215 *
  • 2.4178
  • 2.0083
  • 2.2767
  • 2.0448
  • 2.3621
  • 2.2850
  • 2.8059
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13
  • 1.9781
  • 1.9331
  • 1.9065
  • 1.9918
  • 1.8857
  • 2.0408
  • 3.5728 *
  • 2.0488
  • 2.0854
  • 2.0096
  • 2.1882
  • 2.1035
  • 2.3674
  • 3.9177 *

. 2. 1716.*.2. 3101.*.2. 1716..*. 2. 4072

  • 2.2817
  • 2.5681
  • 3.8532
  • t

.eeeeeeeeeeeeeeeeeeeee**eeeeeeeee 14

  • 2.0109
  • 1.9219
  • 2.0662
  • 1.9631
  • 2.2620
  • 3.4789 *
  • 2.2081
  • 2.0826
  • 2.2685
  • 2.2190
  • 2.6128
  • 3.8484
  • e.2. 4127..*. 2. 2767..*. 2. 4850.*eee.3944
  • 2.8009
  • 3.0146
  • 2

... e eeeeeeeeeeeeeeeeeeeeeeee 15

  • 2.2245
  • 2.9158 ' 2.4165
  • 2.9867
  • 2.5128
  • 3.2909
  • 2.6955
  • 3.3845
  • 150 EFPD 118 % POWER
  • 2.6591
  • 3.4126
  • 2.773d
  • 3.4895
  • 415 EFPD 118 % POWER THIS Is LEVEL 9 OF 18 (LEVEL 18 e TOP OF CORE,' LEVEL 1 m BOTTOM)

H Q

F B

D C

B A

        • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8
  • 2.7901
  • 1.9254
  • 2.0173
  • 1.7829
  • 2.1543
  • 1.9533
  • 1.9880
  • 2.1931 *
  • 2.7350
  • 1.9547
  • 2.0951
  • 1.8711
  • 2.2853
  • 2.0799
  • 2.2784
  • 2.6193
  • ee. 9814.*. 2*.2850 **2 5228......2.e.2221.*. 2.7131
  • 2.4220
  • 2.6853
  • 2.9476 *
  • 2
  • e e...

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.9254
  • 2.2399
  • 1.7728
  • 1.9681
  • 1.7577
  • 1.9331
  • 1.9030
  • 2.8881 *
  • 1.9547
  • 2.3131
  • 1.8601
  • 2.0868
  • 1.8767
  • 2.1392
  • 2.1465
  • 3.4280 *
  • 2.2850
  • 2.7058
  • 2.2237
  • 2.5309
  • 2.2491
  • 2.5828
  • 2.5289
  • 3.7861
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10
  • 2.0173
  • 1.7707
  • 1.9284
  • 1.7351
  • 1.9367
  • 1.8995
  • 2.0608
  • 2.4128 *
  • 2.0951
  • 1.8590
  • 2.0528
  • 1.8568
  • 2.1035
  • 2.0528
  • 2.3515
  • 2.8311 *

..eeeeeeeeeeeeeeeeeeeeeeeee.284.*. 2. 5556

  • 2.4220
  • 2.7616
  • 3.0622 *
  • 2 e..

5228

  • 2.2237
  • 2.5068
  • 2.2

.. eeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1. 7 8 2 9
  • 1. 9 608
  • 1. 7 3 03
  • 2. 07 93
  • 1. 7 3 61
  • 1. 9 9 0 5
  • 1. 9 5 b7
  • 2. 9 9 81 *
  • 1.8711
  • 2.0854
  • 1.8579
  • 2.2565
  • 1.8880
  • 2.2539
  • 2.3017
  • 3.5685 *

. 2. 2221.*.2. 5309..*. 2. 2269..*. 2. 7179

  • 2.2800
  • 2.6863
  • 2.6546
  • 3.8521
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 2.1543
  • 1.7478
  • 1.9260
  • 1.7303
  • 1.9331
  • 1.8755
  • 2.2669 *
  • 2.2853
  • 1.0700
  • 2.0951
  • 1.8834
  • 2.2097
  • 2.1791
  • 2.7281 *
  • 2.7131..*.ee 2.459..*.2. 5535.*eeee.2784
  • 2.6324
  • 2.5309
  • 3. 1044
  • 2 2

eeeeee.

eeeeeeeeeeeeeeeeeeeeeeeee.....

13

  • 1.9533
  • 1.9225
  • 1.8891
  • l'9818
  • 1.0676
  • 2.0264
  • 3.5728 *
  • 2.0799
  • 2.1319
  • 2.0448
  • 2.2475
  • 2.1731
  • 2.4541
  • 4.1303 *
  • 2.4220
  • 2.5807
  • 2.4220
  • 2.6840
  • 2.5289
  • 2.8362
  • 4.2574
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 14
  • 1.9880
  • 1.8995
  • 2.0541
  • 1.9447
  • 2.2507
  • 3.4749 *
  • 2.2784
  • 2.1435
  • 2.3462
  • 2.2967
  • 2.7164
  • 4.0533 *

. 2. 6863..*. 2. 5309.*. 2. 7640..*.2. 6546.*. 3. 0983

  • 4.2103
  • eeeeeeeeeeeeee.

15

  • 2.1931
  • 2.8908
  • 2.4053
  • 2.9839
  • 2.6193
  • 3.4280
  • 2.8260
  • 3.5605
  • 150 EFPD 118 % POWER
  • 2 3.7908
  • 3.0652
  • 3.8568
  • 415 EFPD 118 % POWER e..

9476 *

..eeeeeeeeeeeeeeeeeeeeeeeeeeeees

_ _ ~ _ _ _

.-=

Catawba 2 Cycle 7 Core Operating Limits Report Page 123 of 144 Appendix A TABLE 3 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORRAL OPERATION THIS IS LEVEL 8 OF 18 (LEVEL 18 s TOP OF CORE. LEVEL 1 = BOTTON)

....H.........G.........F.........B.........D.........C.........B.........A.....

8* 2.6401

  • 1.8078
  • 1.8914
  • 1.6798
  • 2.0159
  • 1.8443
  • 1.8790
  • 2.0621 *
  • 2.5537
  • 1.8267
  • 1.9768
  • 1.7673
  • 2.1437
  • 1.9584
  • 2.1377
  • 2.4276
  • e.2 7598
  • 2. 1377..*.2. 3745.*.2. 1021.*.2. 5559.*.2. 3051.*.2. 5765.*.2. 8235..*.

9

  • 1.8078
  • 2.1051
  • 1.6735
  • 1.8579
  • 1.6654
  • 1.8330
  • 1.8036
  • 2.7034 *
  • 1.8267
  • 2.1589
  • 1.7603
  • 1.9756
  • 1.7742
  • 2.0225
  • 2.0186
  • 3.1941 *
  • 2.1377
  • 2.5262
  • 2.1007
  • 2.3889
  • 2.1377
  • 2.4636
  • 2.4257
  • 3.6196
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.8914
  • 1.6717
  • 1.8224
  • 1.6460
  • 1.8384
  • 1.8047
  • 1.9596
  • 2.2800 *
  • 1.9768
  • 1.7584
  • 1.9463
  • 1.7574
  • 1.9930
  • 1.9391
  • 2.2221
  • 2.6412
  • I

... 3745 *.... 2. 1007..*.2.3656

  • 2.1105.*.2. 4239..*.2. 3152..*.2. 6546.*.2. 9366.*.

2

... eeeeeeeee..

11

  • 1.6798
  • 1.8535
  • 1.6417
  • 1.9614
  • 1.6477
  • 1.9016
  • 1.8620
  • 2.8286 *
  • 1.7673
  • 1.9743
  • 1.7574
  • 2.1302
  • 1.7893
  • 2.1392
  • 2.1761
  • 3.3450
  • i
  • 2. 10 2.1.*. 2. 3 9 07.. *. 2. 10 91. *.2.

5 5 5 9.*. e e e.15 8 2

  • 2. 5 6 3 9
  • 2. 5 514
  • 3.7 2 02
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 2.0159
  • 1.6574
  • 1.8299
  • 1.6434
  • 1.8514
  • 1.7932
  • 2.1582 *
  • 2.1437
  • 1.7682
  • 1.9855
  • 1.7853
  • 2.1035
  • 2.0676
  • 2.5807
  • l
  • 2. 5559..*.2. 1348.*.2. 4220..*.2. 1567..*.2. 5088
  • 2.4295
  • 2.9867
  • j

..eeeeeeeeeeeeeeeeeeeeee i

13

  • 1.8443
  • 1.8246
  • 1.7953
  • 1.8925
  • 1.7850
  • 1.9379
  • 3.3898 *
  • 1.9584
  • 2.0147
  • 1.9319
  • 2.1334
  • 2.0608
  • 2.3255
  • 3.8728 *
  • 2. 3051.*. 2. 4636.*.2. 3152.*.2. 56.39..*.2. 4257..*.2. 72.58.*. 4 1136.*

i i

- 14

  • 1.8790
  • 1.7994
  • 1.9523
  • 1.8520
  • 2.1435
  • 3.2980 *
  • 2.1377
  • 2.0173
  • 2.2175
  • 2.1716
  • 2.5702
  • 3.8051
  • 1
  • 2. 5765.*.2. 42.57. *. 2. 6568.*. 2. 5514..*.2. 9839.*.4. 0750..*.

15

  • 2.0621
  • 2.7058
  • 2.2733
  • 2.8159
  • 4 EFPD 118 % POWER J
  • 2.4276
  • 3.1841
  • 2.6390
  • 3.3379
  • 150 EFPD 118 % POWER 1
  • 2. 8235..*. 3. 6196
  • 2. 9366 *.... 3. 7246.*. 415 EPPD 118 % POWER e.

1 THIS IS LEVEL 7 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTON) e...H.........G.........F.........E.........D.........C.........B.........A......

8

  • 2.5346
  • 1.7094
  • 1.7873
  • 1.5791
  • 1.9002
  • 1.7322
  • 1.7643
  • 1.9266 *
  • 2.4053
  • 1.6951
  • 1.8361
  • 1.6361
  • 1.9802
  • 1.8005
  • 1.9584
  • 2.2195 *
  • 2.5346
  • 1.9648
  • 2.17s0
  • 1 2

eeeee**eeeeeeeeeeeeeeeee. 9217

  • 2.3311
  • 2 0909.s*eeee.3255
  • 2.5388 *

........ **eeeeee eeeeeeeeeeeeeee 1.7094

  • 1.9961
  • 1.5823
  • 1.7594
  • 1.5743
  • 1.7285
  • 1.6954
  • 2.5262
  • 9 *
  • 1.6951
  • 2.0064
  • 1.6327
  • 1.8340
  • 1.6454
  • 1.8645
  • 1.8470
  • 2.9059 *

. 1. 9648..*.2.3224

  • 1. 9218..*. 2. 1901..*. 1. 9.478.*. 2. 2400 *..... 2. 1897..**3.263s *

... *eeeeene 10

  • 1.7873
  • 1.5807
  • 1.7323
  • 1.5640
  • 1.7476
  • 1.7038
  • 1.8449
  • 2.1213 *
  • 1.8361
  • 1.6311
  • 1.8108
  • 1.6310
  • 1.8544
  • 1.7914
  • 2.0395
  • 2.4022 *

. 2.e.1780

  • 1.9228
  • 2.1722
  • 1.9301
  • 2.2181
  • 2.1055
  • 2.3999
  • 2.6385
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.5791
  • 1.7554
  • 1.5648
  • 1.8779
  • 1.5735
  • 1.0246
  • 1.7809
  • 2.6591 *
  • 1.6361
  • 1.8319
  • 1.6311
  • 1.9815
  • 1.6628
  • 1.9956
  • 2.0051
  • 3.0477 *
  • 1.9217
  • 2.1903
  • 1.9301
  • 2.3477
  • 1.9824
  • 2.3472
  • 2 3070
  • 3. 3424.*
  • eeeeeeeeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee. eee.

12

  • 1.9002
  • 1.5664
  • 1.7390
  • 1.5687
  • 1.7802
  • 1.7265
  • 2.0689 *
  • 1.9802
  • 1.6387
  • 1.8479
  • 1.6593
  • 1.9830
  • 1.9403
  • 2.3835
  • e.. 3 311.. *. 1. 9 4 4 2.. *. 2. 216 5. *.1.

9 812

  • 2. 3 2 2 0..*.2.2 3 2 9. *. 2. 7127.. *.

2...

eeeee..

ee 13

  • 1.7322
  • 1.7209
  • 1.6954
  • 1.8161
  • 1.7188
  • 1.8590
  • 3.2557 *
  • 1.8005
  • 1.8590
  • 1.7853
  • 1.9905
  • 1.9355
  • 2.1761
  • 3.5770 *
  • 2.0909.*. 2. 2397..*.2. 1055.*. 2. 3472..*.eee.2313
  • 2.5024
  • 3.7289
  • 2 eeeeeeee eeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.7643
  • 1.6926
  • 1.8395
  • 1.7728
  • 2.0555
  • 3.1676 *
  • 1.9504
  • 1.8449
  • 2.0355
  • 2.0013
  • 2.3741
  • 3.5151
  • e.2. 3255..*. 2. 1899..*. 2 4017..*. 2. 3087.* 2.7103
  • 3.6934 *

..eeeeeeeeeeeeeeeeeeeen 15

  • 1.9266
  • 2.5283
  • 2.1169
  • 2.6479
  • 2.2195
  • 2.9044
  • 2.4004
  • 3.0418
  • 150 EFPD 118 % POWER

. 2 5308..*. 3. 2636

  • 2. 6407..*.3. 3495..* 415 EFPD 118 % POWER

l Catawba 2 Cycle 7 Core Operating Limits Report Page 124 of 144 j

Appendix A l

TABLE 3 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORMAL OPERATION j

THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) i l

....H........G.........F.........B......**e.........C.........B.........A......

D l

8

  • 2.4333
  • 1.6399
  • 1.7190
  • 1.5115
  • 1.8316
  • 1.6548
  • 1.6868
  • 1.8465 *
  • 2.2348
  • 1.5731
  • 1.7062
  • 1.5156
  • 1.8435
  • 1.6677
  • 1.8207
  • 2.0596
  • e..

3031.*.1. 7714.*eeee.9749 1.73..68.*.2. 1224... 1. 8972e*eeee.1185

  • 2.3152
  • 2
  • 2 1

eeeeeeeeee.

eeeeeeeeeeeeee.

9

  • 1.6399
  • 1.9254
  • 1.5115
  • 1.6868
  • 1.4977
  • 1.6489
  • 1.6152
  • 2.4352 *
  • 1.5731
  • 1.8724
  • 1.5105
  • 1.7029
  • 1.5211
  • 1.7301
  • 1.7142
  • 2.7068
  • e.1. 7 714. *.2. 10 3 3.. *.1.

7 3 6 8. *.1.9 8 7 4. *. 1. 7 6 21...*. 2. 0 3 6 4..*.1.

9 8 8 5. *. 2. 9 8 5 4.

  • l 10
  • 1.7190
  • 1.5093
  • 1.6576
  • 1.4962
  • 1.6663
  • 1.6194
  • 1.7603
  • 2.0325 *
  • 1.7062
  • 1.5091
  • 1.6803
  • 1.5055
  • 1.7158
  • 1.6577
  • 1.8890
  • 2.2262
  • 1
  • 1.7446
  • 2.0129
  • 1.9055
  • 2.18'5
  • 2.4056 *
  • 1 9749

...... 1. 7369.*.eee.9700 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

11

  • 1.5115
  • 1.6814
  • 1.4827
  • 1.7864
  • 1.4890
  • 1.7275
  • 1.6816
  • 2.5514
  • j l
  • 1.5156
  • 1.7011
  • 1.5056
  • 1.8353
  • 1.5296
  • 1.8365
  • 1.8462
  • 2.8310
  • e.1. 7 3 6 8
  • 1. 9 87 5.. *.1.

7 4 4 4. *.2.12 87.. *.1.7 8 62.. *. 2. 12 6 2.. *. 2. 0 9 2 0. *. 3. 0 5 4 3. *.

12

  • 1.8316
  • 1.4890
  • 1.6576
  • 1.4841
  • 1.6996
  • 1.6391
  • 1.9596 *
  • 1.8435
  • 1.5163
  • 1.7102
  • 1.5266
  • 1.8143
  • 1.7714
  • 2.1938
  • e.2. 1224..*.1. 7602..*. 2.e.0117
  • 1.7852
  • 2.0941
  • 2.0081
  • 2.4573
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 13
  • 1.6548
  • 1.6429
  • 1.6110
  • 1.7200
  • 1.6322
  • 1.7712
  • 3.0967
  • i
  • 1.6677
  • 1.7249
  • 1.6525
  • 1.8311
  • 1.7665
  • 1.9892
  • 3.3112
  • l
  • 1. 8 9 7 2.. *. 2. 0 3 6 2.. *. 1. 9 0 6. 5. *. 2. 12 5 0.. *. 2. 0 0 5 8.. *. 2. 2 5 3 2...*. 3. 3 8 6 6.
  • e 14
  • 1.6868
  • 1.6118
  • 1.7545
  • 1.6735
  • 1.9463
  • 3.0139 *
  • 1.8207
  • 1.7127
  • 1.8856
  • 1.8429
  • 2.1862
  • 3.2514
  • 2.1185
  • 1.9897
  • 2.1850
  • 2.0...934.*.2. 4554.*. 3. 3562..*

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.8465
  • 2.4372
  • 2.0272
  • 2.5391
  • 2.0596
  • 2.7068
  • 2.2239
  • 2.8270
  • 150 EFPD 118 % POWER
  • 2.3152
  • 2.9883
  • 2.4075
  • 3.0573
  • 415 EFPD 118 % POWER
          • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

THIS IS LEVEL 5 OF 18 (LEVEL 18 a TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..C.eeeeeeeeeeeeeeeeeeeeee.

8* 2.3255

  • 1.5648
  • 1.6360
  • 1.4361
  • 1.7404
  • 1.5624 + 1.5898
  • 1.7420 *
  • 2.0545
  • 1.4421
  • 1.5620
  • 1.3850
  • 1.6888
  • 1.5220
  • 1.6562
  • 1.8737 *
  • 1
  • 3.6698
  • 1.0732
  • 2.0483
  • 0034......1. 5376........ 7277
  • 1.5171.*.1 8636
  • 3 e***e

........e**ee....seasessesseseeeeeeee 1.8371

  • 1.4347
  • 1.6003
  • 1.4139
  • 1.5530
  • 1.5226
  • 2.3061
  • 9= 1.5648 *
  • 1.4421
  • 1.7183
  • 1.3786
  • 1.5566
  • 1.3853
  • 1.5734
  • 1.5563
  • 2.4706 *

. 1. 5376... 1 8361..*.1. 5151.*. 1. 7405.*.1 5444.*. 1. 7955..*. 1. 7555.*.2. 6471.*

10

  • 1.6360
  • 1.4334
  • 1.5716
  • 1.4005
  • 1.5716
  • 1.5286
  • 1.6584
  • 1.9207 *
  • 1.5620
  • 1.3777
  • 1.5357
  • 1.3714
  • 1.5628
  • 1.5064
  • 1.7158
  • 2.0269
  • e.1. 7 2 7 7. *.1.515 6.. *. 1. 7 2 5 8.. *. 1. 5 2 47.. *.1. 7 6 8 8
  • 1. e. 6 7 5 2. *eeee**e 9297..*. 2. 1302..*,

1

    • e..

... ee.....

11

  • 1.4361
  • 1.5946
  • 1.3967
  • 1.6827
  • 1.4024
  • 1.6201
  • 1.5751
  • 2.4127 *
  • 1.3850
  • 1.5550
  • 1.3720
  • 1.6730
  • 1.3898
  • 1.6636
  • 1.6720
  • 2.5804 *
  • 1.8695
  • 1.8433
  • 2.7071 *
  • *. 5.171.. a.1 7415.*. 1. 5247..*. 1. 8639..*. 1 5616
  • 1

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.7404
  • 1.4055
  • 1.5630
  • 1.3973
  • 1.5818
  • 1.5226
  • 1.8330 *
  • 1.6888
  • 1.3007
  • 1.5570 1.3862
  • 1.6381
  • 1.5941
  • 1.9835
  • e....

36.*. 1 5422..*.1. 7678... 1. 5608.*. 1. 0332.*. 1. 7589.....

1631..*

  • 2
  • 1.86 ee..

13

  • 1.5624
  • 1.5484
  • 1.5204
  • 1.6118
  • 1.5159
  • 1.6429
  • 2.8991 *
  • 1.5220
  • 1.5687
  • 1.5009
  • 1.6588
  • 1.5889
  • 1.7890
  • 2.9995
  • i

. 1. 6698 *...... 1. 7946...*.1. 6752.*. 1 8685.*.1.7579

  • 1.9751
  • 2.9846 l

l

.ee.

. ee..ee***eseeeee**eeeeee 14

  • 1.5898
  • 1.5196
  • 1.6523
  • 1.5671
  • 1.8193
  • 2.8212 *
  • 1.6562
  • 1.5547
  • 1.7130
  • 1.6685
  • 1.9754
  • 2.9457
  • 1
  • 1.8435
  • e.1 9732..*.1 7564.*eee.9309
2. 1603
  • 2.9556..*

eeeeeeee***....

..e***ee 15

  • 1.7420
  • 2.3078
  • 1.9148
  • 2.4017
  • 1.8737
  • 2.4695
  • 2.0243
  • 2.5762
  • 150 EFPD 118 % POWER
  • 2.0483
  • 2 2

415 EFPD 118 % POWER e e e e e e e.... 6 4 7 4...* e e e.1316. e *.2.

7 0 9 4. * -

    • e e

Catawba 2 Cycle 7 Core Operating Limits Report Page 125 of 144 Appendix A TABLE 3 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORMAL OTERATION THIS IS LEVEL 4 OF 18 (LEVEL 18 TOP OF CORE, LEVEL 1 = BOTTOM) e.........

. 0.........F.........E.........D.........C........ B.........A......

H j

8

  • 2.4140
  • 1.6085
  • 1.6841
  • 1.4638
  • 1.7812
  • 1.5791
  • 1.6085
  • 1.7647 *
  • 2.0381
  • 1.4186
  • 1.5360
  • 1.3542
  • 1.6561
  • 1.4839
  • 1.6063
  • 1.8180
  • 1
  • 1.8250
  • 1.3930
  • 1.5684
  • 1.3760
  • 1.6954
  • 1.5155
  • 1.7060
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.1. 87.61.*

9

  • 1.6085
  • 1.8954
  • 1.4666
  • 1.6306
  • 1.4321
  • 1.5739
  • 1.5384
  • 2.3468 *
  • 1.4186
  • 1.6944
  • 1.3487
  • 1.5267
  • 1.3513
  • 1.5312
  • 1.5092
  • 2.4063 *
  • 1.3930
  • 1.6680.*. 1.3736.*.1. 5802
  • 1 4015.*. 1. 6314.*. 1.e.5933
  • 2.4309 eeeeeeeeeeeee....

eeeeee.

.eeee*e....

ee.

eeeeeeeeeeeeee.

10

  • 1.6841
  • 1.4645
  • 1.6109
  • 1.4210
  • 1.5971
  • 1.5484
  • 1.6814 8 1.9520
  • 1.5360
  • 1.3475
  • 1.5066
  • 1.3383
  • 1.n271
  • 1.4652
  • 1.6667
  • 1.9724
  • 1

. 1 5684

  • 1. 3736.*.1. 5661.*.1. 3820 *... 1.6067
  • 1.5208
  • 1.7603
  • 1.9549
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.4638
  • 1.6326
  • 1.4164
  • 1.7140
  • 1.4216
  • 1.6411
  • 1.5$04
  • 2.4656
  • 1.3542
  • 1.5252
  • 1.3389
  • 1.6356
  • 1.3519
  • 1.6158
  • 1.6195
  • 2.5199 *

. 1 3760.*. 1. 5810.*. 1. 3819..*.1. 6928.*eee.4128

  • 1.7003
  • 1.6779
  • 2.4949
  • 1 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

1.5882

  • 1.4164
  • 1.5971
  • 1.5309
  • 1.8546
  • 12
  • 1.7812
  • 1.4229 *
  • 1.6561
  • 1.3464
  • 1.5212
  • 1.3484
  • 1.5880
  • 1.5380
  • 1.9194 *
  • 1.6954
  • 1.3995
  • 1.6057
  • 1.4120
  • 1.6646
  • 1.5953
  • 1.9745
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.5791
  • 1.5692
  • 1.5392
  • 1.6326
  • 1.5234
  • 1.6541
  • 2.9411 *
  • 1.4839
  • 1.5260
  • 1.4594
  • 1.6108
  • 1.5335
  • 1.7233
  • 2.9167
  • eseeeeeeeeeeeeeeeeeeeeeeee.. 1. 6996.*eee.5937
  • 1.7952
  • 2.7423..*
  • 1.5155
  • 1.6312
  • 1.5208
  • 1

.. e eeeeeeeeeeeeeeeeeee 14

  • 1.6085
  • 1.5354
  • 1.6761
  • 1.5823
  • 1.8416
  • 2.8609 *
  • 1.6063
  • 1.5077
  • 1.6641
  • 1.6154
  • 1.9113
  • 2.8631 *
  • 1. 7060.*. 1. 5961.*.1. 7613.*.1. 6788.*. 1 9720..*. 2. 7142..*.

e.

15

  • 1.7647
  • 2.3506
  • 1.9471
  • 2.4521
  • 1.0180
  • 2.4063
  • 1.9699
  • 2.5138
  • 150 EPPD 118 % POWER e e e 87 61
  • 2. 4309
  • 1. 9 561
  • 2. 49 84.*. 415 EFPD 118 % POWER
  • 1

..eeeeeeeeeeeeeeeeeeeeeeee THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

C B

A

.... H......... G......... F......... E......... D.. e e... e e e e e e e e e e e e e e e e e e e e e e e e.

8

  • 2.5537
  • 1.7019
  • 1.7742
  • 1.5278
  • 1.8438
  • 1.6152
  • 1.6386
  • 1.8131 *
  • 2.0620
  • 1.4336
  • 1.5455
  • 1.3551
  • 1.6468
  • 1.4718
  • 1.5735
  • 1.7877
  • 1 4414
  • 1.2629
  • 1.5547
  • 1.3807
  • 1.5541
  • 1.7184
  • e+ 6846
  • 1.2783 *1.***ee
        • eeeeeee.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee** esesseeeeeen 9
  • 1.7019
  • 1.9935
  • 1.5415
  • 1.7125
  • 1.4770
  • 1.6101
  • 1.5743
  • 2.4064
  • 1.4336
  • 1.7031
  • 1.3554
  • 1.5309
  • 1.3505
  • 1.5107
  • 1.4854
  • 2.3592
  • e.1. 2 7 8 3. *. 1. 5 3 2 0.. *.1.

2 614. *. 1. 4 5 2.1. *. 1. 2 87 7.. *. 1. 4 9 0 5. *.1.

4 5 5 9. *e e e e. 2 2 3 4

  • 2 ee e.

eeeee.

. 10

  • 1.7742
  • 1.5400
  • 1.6886
  • 1.4777
  • 1.6497
  • 1.5969
  • 1.7256
  • 2.0272 *
  • 1.5455
  • 1.3545
  • 1.5099
  • 1.3409
  • 1.5217
  • 1.4520
  • 1.6408
  • 1.9562 *
  • 1.4414
  • 1.2624
  • 1.4302
  • 1.2711
  • 1.4745
  • 1.3899
  • 1.6078
  • 1.7994
  • eeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 11
  • 1.5278
  • 1.7060.* 1.4735
  • 1.7708
  • 1.4763
  • 1.6895
  • 1.6391
  • 2.5639 *
  • 1.3551
  • 1.5294
  • 1.3413
  • 1.6244
  • 1.3473
  • 1.5970
  • 1.5975
  • 2.4984 *

..1 2629.*.1. 4527..*.1. 2711.*.1. 5507..*.1. 2940..*. 1. 5553..*. 1 5355..*. 2. 3015.*.

12

  • 1.8438
  • 1.4679
  • 1.6403
  • 1.4721
  • 1.6446
  • 1.5751
  • 1.9097 *
  • 1.6468
  • 1.3453
  • 1.5157
  • 1.3435
  • 1.5691
  • 1.5169
  • 1.8869
  • 1 e.1. 5547..*. 1. 2856..*. 1. 4731
  • 1. 2930..*ee 5226 ' 1.4559
  • 1.8045 *

.ee.

.eeeeeeeeeeeeeeeeeee.

13

  • 1.6152
  • 1.6044
  • 1.5872
  • 1.6814
  • 1.5679
  • 1.6977
  • 3.0199 *
  • 1.4718
  • 1.5056
  • 1.4468
  • 1.5917
  • 1.5118
  • 1.6892
  • 2.8668 *
  • 1
          • ee 5545 *.... 1.4546......1 6370... 2. 5081.*
      • 3807..*.1. 4898
  • 1.3898
  • 1 ee.

14

  • 1.6386
  • 1.5719.* 1.7190
  • 1.6305
  • 1.8948
  • 2.9326 *
  • 1.5735 *.1.4840
  • 1.6378
  • 1.5926
  • 1.8779
  • 2.0098 *
  • 1.5541
  • 1.4566
  • 1.6092
  • 1.5363
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..... 1. 8024... 2. 4820..*.

15

  • 1.8131
  • 2.4083
  • 2.0219
  • 2.5514
  • 4 EPPD 118 % POWER
  • 1.7877
  • 2.3592
  • 1.9543
  • 2.4934
  • 150 EFPD 110 4 POWER

. 1. 7104

  • 2. 2250..*. 1. 8004.*.2. 30.44.*. 415 EFPD 118 % POWER

Catawba 2 Cycle 7 Core Operating Limits Report Page 126of144

/4ppendix A TABLE 3 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - NORMAL OPERATION THIS IS LEVEL' 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) e.. H......... G.... e e e e e e e e e e e e e e e........ D.........C......... B......... A......

F E

8

  • 3.0501
  • 2.0843
  • 2.1567
  • 1.8334
  • 2.1347
  • 1.8280 *~1.8352
  • 2.1140 *
  • 2.3424
  • 1.6724
  • 1.7818
  • 1.5565
  • 1.8385
  • 1.6474
  • 1.7009
  • 1.9925 *
  • 1.7404
  • 1.3312
  • 1.4912
  • 1.3058
  • 1.5830
  • 1.4086
  • 1.5530
  • 1.7561
  • eeeeeeeeeeeeeeeeee***eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 2.0843
  • 2.3950
  • 1.8800
  • 2.0595 *'1.7122
  • 1.8193
  • 1.7819
  • 2.7058
  • 1.6724
  • 1.9400
  • 1.5740
  • 1.7569
  • 1.5160
  • 1.6627
  • 1.6325
  • 2.5394
  • 1.3312
  • 1.5732
  • 1.3064
  • 1.5033
  • 1.3245
  • 1.5047
  • 1.4730
  • 2.2206
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
  • 2.4241
  • 10
  • 2.1567
  • 1.8777
  • 2.0474
  • 1.7697
  • 1.9190
  • 1.8378
  • 1.9608 1.7818
  • 1.5733
  • 1.7366
  • 1.5413
  • 1.7023
  • 1.6241
  • 1.7977
  • 2.2267 *
1. 3075.*. 1.4870
  • 1.3113
  • 1.5127
  • 1.4129
  • 1.6192..*. 1 8569.*e
  • 1.4912
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

eeeeeee....

11

  • 1.8334
  • 2.0501
  • 1.7637
  • 2.0708
  • 1.7255
  • 1.9499
  • 1.9054
  • 3.0269 *
  • 1.5555
  • 1.7525
  • 1.5379
  • 1.8192
  • 1.5424
  • 1.7704
  • 1.7799
  • 2.8009 *
  • 1.3058
  • 1.5033
  • 1.3107
  • 1.5813
  • 1 2

eseeeeeeeeeeeeeee**eeeeeeeeeeeeeeeeeee. 3340

  • 1.5814
  • 1 5671e*eeee.3632 *

. eeeeeeeeeeeeee...

eeeeee 12

  • 2.1347
  • 1.7019
  • 1.9085
  • 1.7179
  • 1.9190
  • 1.8248
  • 2.2066 *
  • 1.8385
  • 1.5102
  • 1.6945
  • 1.5386
  • 1.7629
  • 1.6855
  • 2.0788
  • eeeeee.0.*. 1. 3195
  • 1.5113
  • 1.3329
  • 1.5553
  • 1.4818
  • 1.533 1.8247
  • e

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.8280
  • 1.8130
  • 1.8291
  • 1.9391
  • 1.8152
  • 1.9657
  • 3.4203 *
  • 1.6474
  • 1.6574
  • 1.6195
  • 1.7644
  • 1.6796
  • 1.8643
  • 3.1116 *
  • 1.4086
  • 1.5039
  • 1.4124
  • 1.5809
  • 1.4797
  • 1.6573
  • 2.5139 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.8352
  • 1.7788
  • 1.9535
  • 1.8961
  • 2.1897
  • 3.3268 *
  • 1.7009
  • 1.6308
  • 1.7946
  • 1.7749
  • 2.0692
  • 3.0476
  • eeee.530..*.1 4737..*.1.6200.*.1 5671
  • 1.8226
  • 2.4877
  • 1.5...

..se

.....eeeeeeeeeeeeeeeeeeeeee 15

  • 2.1140
  • 2.7058
  • 2.4165
  • 3.0124
  • 1.9925
  • 2.5394
  • 2.2243
  • 2.7945
  • 150 EFPD 118 % POWER eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.55.* 415 BFPD 118 % POWER 1.7561
  • 2.2206
  • 1.8580
  • 2.36...

THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

  • eeeeeee.....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8

  • 4.5844
  • 6.1295
  • 3.4176
  • 5.1708
  • 3.1808
  • 2.5811
  • 2.8210
  • 3.5475 *
  • 3.4583
  • 4.3227
  • 2.7720
  • 3.8683
  • 2.7296
  • 2.2806
  • 2.4970
  • 3.1642 *
  • 2.3634
  • 2.7187
  • 2.0979
  • 2.6302
  • 2.1362
  • 1.8630
  • 2.0386
  • 2.4630
  • eeeeeeee****eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese*ee***eesessese.*
  • 2.6538
  • 4.1642
  • 9
  • 6.1295
  • 3.6898
  • 5.3396
  • 3.1732
  • 4.5567
  • 2.8439
  • 4.3227
  • 2.9411
  • 3.9261
  • 2.6879
  • 3.5798'* 2.4802
  • 2.3700
  • 3.7051
  • e.2 7187.*.2. 1604.*.2. 6346
  • 2.1049
  • 2.5826
  • 2.0090
  • 9 3 47.. *. 2. 9 0 6 8.. *.

1

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 3.4176
  • 5.3396
  • 3.2687
  • 4.9643
  • 3.0096
  • 2.6403
  • 3.0622
  • 7.3641 *
  • 2.7720
  • 3.9261
  • 2.7298
  • 3.7867
  • 2.6416
  • 2.3202
  • 2.6938
  • 6.0023 *
  • 2.0979.*. 2. 6346.*. 2. 0.937...*.2.6302..*. 2. 0673
  • 1.8716
  • 2.1623
  • 4.0864 *
      • e

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 5.1708
  • 3.1573
  • 4.9485
  • 3.0563
  • 4.5835
  • 3.0153
  • 3.0378
  • 4.7527 *
  • 3.8683
  • 2.6788
  • 3.7731
  • 2.6886
  • 3.6697
  • 2.6732
  • 2.7079
  • 4.1910 *

.. e e. 2. 10 4 9.

  • e e e. 6 2 8 0
  • 2.13 7 7.. *. 2. 6 4 0 4. *. 2. 12 91.. *. 2. 13 3 4. *. 3. 18 3 3.. * '

2

. 2. 6302

  • eeeeeeeeee 12
  • 3.1808
  • 4.5235
  • 2.9924
  • 4.5634
  • 3.0240
  • 2.8589
  • 3.5726 *
  • 2.7296
  • 3.5615
  • 2.6284
  • 3.6611
  • 2.6765
  • 2.5497
  • 3.1769 *

. 2.e.1362

  • 2. 5744
  • 2.0635
  • 2.6388
  • 2. 1377.*.2 0141
  • 2.4746 i

e......

.eeeeeeeeeeeeeeeee.....

.eeeeeeeeeeee.

13

  • 2.5811
  • 2.8336
  • 2.6291
  • 3.0038
  • 2.8458
  • 3.2153
  • 5.3311 *
  • 2.2006
  • 2.4744
  • 2.3124
  • 2.6652
  • 2.5415
  • 2.8735
  • 4.6246
  • i e.1. 8630..*e**.0068
  • 1.8708
  • 2.1277..*.2. 0116.*.2. 2587..*. 3.3709 2

eeeeeeeeeeeeeeeeeee ee.

14

  • 2.8210
  • 2.6516
  • 3.0533
  • 3.0230
  • 3.5444
  • 5.1946 *
  • 2.4970
  • 2.3700
  • 2.6892
  • 2.6996
  • 3.1610
  • 4.5314
  • eeeeeeeee. 1. 9359..*eeee.1627
  • 2.1334
  • 2.4707
  • 3.3313 *
  • 2.0386
  • 2 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 3.5475
  • 4.1642
  • 7.3467
  • 4.7384
  • 4 EFPD 118 % POWER i
  • 3.1642
  • 3.7076
  • 5.9961
  • 4.1854
  • 150 EFPD 118 % POWER

. 2. 4630 *... 2. S. 07 5. *. 4. 0 9 0 3.. *. 3. e.19 01

  • 415 EFPD 118 % POWER-
    • eee.

Catawba 2 Cycle 7 Core Operating Limits Report Page 127 of 144 Appendix A n

TABLE 4 M-SUB-C VALUBS (F-SUB-Q RPS MARGIN) - POWER ESCALATION AT 118% POWER, 4 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeseneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 88 5.2035 7.5064 4.1082 6.4743 3.8581 3.3308 3.6012 4.4650 9'

7.5064 4.3611-6.6688 3.8148 5.8087 3.5807 3.4415 4.9902 10*

4.1082 6.6688 3.9046 6.2528 3.6940 3.3889 3.7918 8.9044 11*

6.4743 3.7964 6.2403 3.6808 5.7656 3.6555

.3.8177 5.4422 12*

3.8581 5.7763 3.6811 5.7549 3.5970 3.6052 4.2813 13*

3.3308 3.5766 3.3816 3.6470 3.5968 3.9388 5.9223 14 * - 3.6012 3.4415 3.7827 3.8084 4.2639 5.7982 15

  • 4.4650 4.9902 8.8790 5.4234 AT 118% POWER, 4 EFPD, THIS 18 LEVEL 17 OF 18 (LEVIL 18 = TOP OF CORE,' LEVEL 1 = BOTTOM)

H-

.O F

E D

C

.. B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

3.6853.~

2.7332 2.7910 2.4605

'2.7252 2.4802 2.4579' 2.8073 9*

2.7332 3.0080.

2.518&

2.6658 2.3226 2.4164 2.4297

'3.4012 10*

2.7910 2.5143 2.6368 2.3868 2.5148 2.5041 2.5494 3.0922 11*

2.4605 2.6568 2.3832 2.6773 2.3278 2.5269 2.5245' 3.6512 12*

2.7252 2.3140 2.5068 2.3226 2.4598' 2.4547 2.7934 13*

2.4802 2.4109 2.5001 2.5208-2.4489 2.5494 4.0265 14*

2.4579 2.4260 2.5432 2.5163' 2.7811 3.9329 15

  • 2.8073 3.4050 3.0860 3.6428 1

l i

J 1

-n r

i i

Catawba 2 Cycle 7 Core Operating Limits Report Page 12tiof 144 Appendix A

}

j TABLE 4 (CONTINUBD)

M-8UB-C VALUES (F.8UB-Q RPS KARGIN) - POWER ESCALATION -

l 4

j AT 118% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON) ee.eeeeeeee.eeeeee....F...eeeee.Eeeeeeee..D...eeeeeeeeeeeeeeee.ee..eeee ee..

)

H 0

C' B

A 4

1 8*

3.0080 2.1506 2.2050 1.9644 2.2649 2.0899 2.0937 2.3243

)

l 9*

2.1506 2.4198 1.9794 2.1291 1.9124 2.0368 2.0378 2.9298 10*

2.2050 1.9781 2.0881 1.9077 2.0649 2.0580 2.1450 2.5122 11*

1.9644 2.1219 1.9042 2.1963 1.8949 2.0965 2.0759 3.0182 t

12*

2.2649 1.9042 2.0581 1.8949 2.0251 2.0101 2.3341 13*

2.0899 2.0316 2.0526-2.0895 2.0049 2.1140 3.4789 4

14*

2.0937 2.0351 2.1392 2.0690 2.3220 3.3936 15

  • 2.3243 2.9326 2.5062 3.0067 AT 118% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LNVEL 1 = BOTTOM)

H e e e e e e e e e. e e e e e...E. e e e e e e e e e e'e e e e e e e e e e e. e e e e e e e e e eeeeeeeeeeee G F

D C

B A

..eeeeeee 88 2.7301 1.9159, 1.9681 1.7597 2.0638 1.9077 1.9190 2.1227 i

98 1.9159 2.1805 1.7587 1.9097, 1.7255 1.8579 1.8542 2.7131 1

10*

1.9681 1.7567 1.8678 1.7075 1.8678 1.8553 1.9596 2.2834 j

11*

1.7597 1.9028.

1.7047 1.9961 1.7028 1.9016

-1.8800 2.7616 12*

2.0638 1.7179 1.8601 1.7028 1.8373 1.8152 2.1319 13*

1.9077 1.8503-1.8487 1.8948 1.8089 1.9249 3.2349

)

14*

1.9190 1.8509 1.9547 1.8721 2.1205 3.1512 i

15

  • 2.1227 2.7155 2.2783 2.7520 i

i a

4 e

b d

9 f

i 6

f 4

w.

~

i

)

I Catawha 2 Cycle 7 Core Operating 1,imits Report Page 129 of 144 Appendix A 1

j TABLE 4 (CONTINUED) 1 M-SUB-C VALUES (F-SUB-Q RPS KARGIN) - POWER ESCALATION' AT 118% POWER, 4 EFPD.

THIS IS LNVEL 14 OF 18 l

(LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM) l H

G F

B C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee..D..eeeeeeeeeeeeeeeeeeeeeeeeeeee...

i 8*

2.7082 1.8766 1.9343 1.7274 2.0471 1.8846 1.9051 2.1069 l

9*

1.8766 2.1543 1.7207 1.8812 1.6972 1.8395 1.8313 2.7155 10*

1.9343 1.7179 1.8395 1.6753 1.8427 1.8237 1.9451 2.2650 i

11 1.7274 1.8745 1.6717 1.9754 1.6735 1.8801 1.8564 2.7544 12*

2.0471 1.6880 1.8352 1.6708 1.8182 1.7870 2.1176 13*

1.8846 1.0309 1.8173 1.8734 1.7809 1.9074 3.2418 14*

1.9051-1.8280 1.9403 1.8407 2.1049 3.1577 15

  • 2.1069 2.7179 2.2601 2.7424 AT 118% POWER, 4 RFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

2.6679 1.8356' 1.8891 1.6899 2.0093 1.8465 1.8667-2.0621 9*

1.8356 2.1125 1.6798 1.8395 1.6592 1.8016 1.7922 2.6702 10*

1.8891 1.6771 1.7985 1.6373 1.8026 1.7829 1.9074 2.2213 11*

1.6899 1.8330 1.6330 1.9364 1.6373 1.8395 1.8152 2.7094 12*

2.0093 1.6504 1.7944 1.6330 1.7802 1.7459 2.0758 13*

1.8465 1.7934 1.7768 1.8320 1.7390 1.8656 3.1942 14*

1.8667 1.7891 1.9016 1.8068 2.0622 3.1093 15

  • 2.0621 2.6726 2.2150 2.6978 t

l i

h l

=

w w

Catawba 2 Cycle 7 Core Onerating Limits Report Page 130 of 144 Aprendix A TABLE 4 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - POWER ESCALATION AT 118% POWER, 4 BFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

H O

P E

D C

B-A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

2.7623 1.8869 1.9451 1.7361 2.0750 1.8961 1.9213 - 2.1198 9'

1.8869 2.1805 1.7236 1.8948 1.7047 1.0568 1.0421 2.7573 10*

1.9451 1.7217 1.8535 1.6825 1.8579 1.0334. 1.9657 2.2867 11*

1.7361

'1.8880 1.6780 1.9987

-1.6834 1.8971-1.8676 2.8034

'12*

2.0750 1.6954 1.8492 1.6780 1.8363 1.7953 2.1435 l

13*

1.8961 1.8481 1.8259 1.8891 1.7881 1.9237 3.3123 14*

1.9213 1.8378 1.9596 1.8598 2.1305 3.2246 15

  • 2.1198 2.7598 2.2817 2.7910 i

i AT 118% POWER, 4 EFPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) l H

O F

E D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l

8*

2.8556 1.9669 2.0341 1.8089 2.1728 1.9744.

2.0032 2.2009 l

9*

1.9669 2.2836 1.7963 1.9843 1.7768 1.9415 1.9183 2.8772 10*

2.0342 1.7943 1.9427 1.7557 1.9463 1.9136 2.0568 2.3868 11*

1.8089 1.9768 1.7508 2.0950' 1.7567 1.9893 1.9508. 2.9394 12*

2.1728 1.7667 1.9367 1.7508 1.9284 1.8789' 2.2491 13*

1.9744 1.9331 1.9054 1.9818 1.0721 2.0186 3.4869 14*

2.0032 1.9148 2.0514 1.9423 2.2348 3.3936 15

  • 2.2009 2.8799 2.3813 2.9284 f

wo i

1' i

I i

l i

l nem - w ra v

e f - -

Catawba 2 Cycle 7 Core Operating Limits Report Page 131 of 144 Appendix A TABLE 4 (CONTINUED)

M-8UB-C VALUES (F.SUB-Q RPS KARGIN) - POWER ESCALATION AT 118% POWER, 4 EFPD,- THIS IS LEVEL 10 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 e BOTTON)

H F

B D

C-B A

...ee........O....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee*eeeeeee eeeeeeeeeeeeeeeen e

B*

2.8290 1.9582 2.0212 1.7994 2.1620

.1.9781 2.0109 2.2245 9*

1.9582 2.2717 1.7860 1.9731 1.7728 1.9427 1.9266

-2.9130 10*

2.0212 1.7840 1.9319 1.7500 1.9463' 1.9171 2.0730 2.4222 11*

1.7994 1.9669 1.7459 2.0864 1.7518 2.0019 1.9719 2.9981 12*

2.1620 1.7627 1.9367 1.7468 1.9427 1.8938 2.2767 13*

1.9781 1.9331 1.9065 1.9918 1.8857 2.0408 3.5728 14*

2.0109 1.9219 2.0662 1.9631 2.2620 3.4*/09 15

  • 2.2245 2.9158

'2.4165 2.9867 AT 118% POWER,

& EFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTON)

H O

F E

D C

B A

seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese 8*

2.7901 1.9254

'2.0173 1.7829 2.1543 1.9533 1.9880 2.1931 10*

2.0173 ~ 2.2399 1.7728 1.9681 1.7577 1.9331 1.9030 2.8881 9*

1.9254 1.7707 1.9284 1.7351 1.9367 1.8995 2.0608 2.4128 11*

1.7829 1.9608 1.7303 2.0793 1.7361 1.9905 1.9557 2.9981 12*

2.1543 1.7478 1.9260 1.7303 1.9331 1.8755 2.2669 l

13*

1.9533 1.9225 1.8891 1.9818 1.8676 2.0264 3.5728 14*

1.9800 1.8995 2.0541 1.9447 2.2507 3.4749 15

  • 2.1931 2.8908 2.4053 2.9839 l

t 1

.l

4 l

l Catawba 2 Cycle 7 Core Operating Limits Report Page 132 of 144 Apggndix A t

I TABLE 4 (CONTINUED) l' M-SUS-C VALUES (F-SUB-Q RPS MARGIN) - POWER ESCALATION AT 118% POWER, 4 EFPD, THIS IS LEVEL. 8 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM)

H.

Q

.F E

A e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.......D.........C.........B..... e e e e e e e e.

8*

2.6401 1.8078 1.8914 1.6798 2.0159 1.8443 1.8790 2.0621, 9*

1.8078 2.1051 1.6735 1.8579 1.6654 1.8330 1.8036 2.7034 10*

1.8914 1.6717 1.8224 1.6460 1.8384.

1.8047 1.9596 2.2800 11*

1.6798 1.8535 1.6417 1.9614 1.6477 1.9016 1.8620 2.8286 12*

2.0159 1.6574 1.8299 1.6434 1.8514 1.7932 2.1582

'13*

1.8443 1.8246 1.7953 1.8925 1.7850.

1.9379 3.3898 14*

1.8790 1.7994 1.9523 1.8520 2.1435

-3.2980 15

  • 2.0621' 2.7050 2.2733 2.8159 AT 118% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 I

.(LEVEL 18 m TOP OF CORE, LEVEL 1 m BOTTOM).

H-0 F

B D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-8*.2.5346 1.7094 1.7873 1.5791.

1.9002 1.7322 1.7643 1.9266 9*

1.7094 1.9961 1.5823 11.7594 1.5743 1.7285 1.6954 2.5262 10*

1.7873 1.5807

.1.7323 1.5640 1.7476 1.7038 1.8449 2.1213 11*.1.5791.-

1.7554 1.5648 1.8779-1.5735 1.8246f 1.7809 2.6591 l

12*

1.9002 1.5664 1.7390 1.5687 1.7802 1.7265

'2.0689 13*

1.7322 1.7209 1.6954 1.8161 1.7188-1.8590 3.2557 t

14*

1.7643 1.6926 1.8395 1.7728 2.0555 3.1676 15

  • 1.9266 2.5283 2.1169 2.6479-i a- -

~ ' ' "

Catawba 2 Cycle 7 Core Operating Limits Report Page 133 of 144 Aqppendix A TABLE 4 (CONTINUED)

H-SUB-C VALUES (F-SUB-Q RPS MAROIN) - POWER ESCALATION AT 118% POWER, 4 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

. B A'

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

2.4333 1.6399 1.7190 1.5115 1.8316 1.6548 1.6868 1.8465 9*

1.6399 1.9254 1.5115 1.6868 1.4977 1.6489 1.6152 2.4352 10*

1.7190.

1.5093 1.6576 1.4862 1.6663

.1.6194 1.7603 2.0325 11*

1.5115 1.6814 1.4827 1.7864 1.4890 1.7275 1.6816 2.5514 l

12*

1.8316 1.4890 1.6576 1.4841 1.6996 1.6391 1.9596

-13*

1.6548 1.6429 1.6110 1.7200' 1.6322 1.7712 3.0967 14*

1.6868 1.6118 1.7545 1.6735 1.9463 3.0139 15

  • 1.8465 2.4372 2.0272 2.5391

{

AT 118% POWER, 4 EFPD, THIS IS LEVEL 5 OF 18

[

(LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTON) l H

G F

E D

C B

A l

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

2.3255 1.5648 1.6360 1.4361 1.7404 1.5624 1.5898 1.7420' i.

9*

1.5648 1.8371 1.4347 1.6003 1.4139 1.5530 1.5226 2.3061 l

10*

1.6360 1.4334 1.5716 1.4005 1.5716 1.5286 1.6584 1.9207 t

12*

1.7404 1.4055 1.5630 1.3973

,1.4024 1.6201 1.5751 2.4127 11*

1.4361 1.5946 1.3967 1.6827 1.5818-1.5226 1.8330 13*

1.5624 1.5484 1.5204 1.6118 1.5159',1.6429 2.8991 14*

1.5898 1.5196 1.6523 1.5671. 1.8193 2.8212 15

  • 1.7420 2.3078 1.9148 2.4017 o

w m-m

,m_

jy c-g

+

--.g

l l

Catawba 2 Cycle 7 Core Operating Limits Report Page 134 of 144 Appendix A i

4 TABLE 4 (CONTINUED)

(

M-SUB-C VALUES (F-SUB-Q RPS MARGIN) - POWER ESCALATION AT 118% POWER, 4 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) 0 D

C A

.ee.Heeeeeee.eeeeees..F......e..E..e.ee.eeeeeeeeeeeee...... Bee.eeeee.ee.ee 8*

2.4140 1.6085 1.6841 1.4638 1.7812 1.5791 1.6083 1.7647 9*

1.6085 1.8954 1.4666 1.6386 1.4321 1.5739 1.5384-2.3488

' 10

  • 1.6841 1.4645 1.6109 1.4210 1.5971 1.5484 1.6814 1.9520 l

11*

1.4638 1.6326 1.4164 1.7140 1.4216 1.6411

'1.5904

.2.4656 12*

1.7812 1.4229 1.5882 1.4164 1.5971 1.5309 1.8546 13*

1.5791 1.5692 1.5392.

1.6326 1.5234 1.6541 2.9411 14*

1.6085 1.5354 1.6761 1.5823 1.8416 2.8609 15

  • 1.7647 2.3506 1.9471 2.4521 AT 110% POWER, 4 EFPD, THIS IS LEVEL 3 OF 18-(LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON) eeeeeeeeeeeeeee.eeeeeeeeeeeeeee.ee.eeeeeeeeeeeeeeee.e..se.Beeeeeeee.A.ee.

H G

F E

D C

es 8*

2.5537 1.7019 1.7742 1.5278 1.8438 1.6152 1.6386 1.8131 9*

1.7019 1.9935 1.5415 1.7125 1.4770 1.6101 1.5743 2.4064 10*

1.7742 1.5400 1.6886 1.4777 1.6497 1.5969 1.7256 2.0272 11*

1.5278 1.7060 1.4735 1.7708 1.4763 1.6895

'1.6391 2.5639 12*

1.8438 1.4679 1.6403 1.4721 1.6446 1.5751 1.9097 13*

1.6152 1.6044 1.5872 1.6814 1.5679 1.6977 3.0199 14*

1.6386 1.5719 1.7190

.1.6305 1.8948 2.9326 15

  • 1.8131 2.4083-2.0219 2.5514 l

4 I

l l

h l

l l

I

[

i w

r,,-

Catawba 2 Cycle 7 Core Operating Limits Report Page 135 of 144 Appendix A TABLE 4 (CONTINUED)

M-SUB-C VALUES (F-SUB-Q RPS KARGIN)

POWER ESCALATION AT 118% POWER, 4 EFPD,.

THIS IS LEVEL 2 OF lb (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)-

H G

F E

D C

B

.A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

3.0501 2.0843 2.1567 1.8334 2.1347 1.8280 1.8352 2.1140 9*

2.0843 2.3950 1.8800 2.0595 1.7122 1.8193-1.7819 2.7058 10*

2.1567 1.8777 2.0474 1.7697 1.9190 1.8378 1.9608 2.4241 11*

1.8334 2.0501 1.7637 2.0708 1.7255 1.9499 1.9054 3.0269

.12*

2.1347 1.7019 1.9085 1.7179 1.9190 1.8248 2.2066 13*

1.8280 1.8130 1.8291 1.9391-.1.8152 1.9657 3.4203 14*

1.8352 1.7788 1.9535 1.8961 2.1897' 3.3268 15

  • 2.1140

.2.7058 2.4165

'3.0124 AT 118% POWER, 4 EFPD,. THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTON)

H G

F E

D C

B A

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eaeeeeeeeee 8*

4.5844 6.1295 3.4176 ~ 5.1708 3.1808 2.5811 2.8210 3.5475 9*

6.1295 3.6898 5.3396 3.1732 4.5567 2.8439 2.6538 4.1642 10*

3.4176 5.3396 3.2687 4.9643 3.0096 2.6403 3.0622 7.3641 11*

5.1708 3.1573.

4.9485 3.0563 4.5835

.3.0153 3.0378 4.7527 12*

3.1808 4.5235 2.9924 4.5634 3.0240 2.8589 3.5726 13*. 2.5811 2.8336 2.6291 3.0038 2.8458 3.2153 5.3311 14*- 2.8210 2.6516 3.0533 3.0230 3.5444

.5.1946 15

  • 3.5475 4.1642 7.3467 4.7384

~

l 1

l l

I l.

_m i

Catawha 2 Cycle 7 Core Operating Limits Report Page 136 of 144 Appendix A-1 l

TABLE 5 i

F-DEL-H & M-DEL-H VALUES - NORMAL OPERATION l

I AT 100% POWER, 4 RFPD A'

.... H......... G........ F......... E......... D......... C.........' B..... e e e e e e e e e.

8*

.8290

  • 1.2160
  • 1.2180
  • 1.3260
  • 1.1140
  • 1.2480
  • 1.2490 * '1.0900
  • 1.2483
  • 1.2856
  • 1.1544
  • 1.4075
  • 1.2473
  • 1.2426
  • 1.4008 *
  • 1.8482
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee l'

9

  • 1.2160
  • 1.0520
  • 1.3310
  • 1.2510
  • 1.3520
  • 1.2910
  • 1.2790 *

.8290

  • 1.2 4 8.*. 1 47 64
  • e e e.1514
  • 1.2 5 63
  • 1.13 6 8
  • 1. 2 2 01
  • 1.218 0
  • 1. 842 6
  • 1 eeeeee.3 e

. eee**

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeen 10

  • 1.2180
  • 1.3320
  • 1.2760
  • 1.3650
  • 1.2810
  • 1.2850
  • 1.2070 *

.9750 *

. 1. 2 8 5 6. *. 1. 15 0 5..*.1.

2 314.

  • 1. 12 8 2.. *.1.

2 3 27.. *e.1. e. 2 3 3 0.. *.1.

2 9 5 2.. *.1 5 3 2 0..*.

een.

l 11

  • 1.3260
  • 1.2560
  • 1.3690
  • 1.1540
  • 1.3650
  • 1.2480
  • 1.2380 *

.8250 *

  • 1.1544
  • 1.2523.*. 1. 1257
  • 1.3685
  • 1. 1292.e*eeee.2629
  • 1.2626
  • 1.8549
  • 1 e eeeeeeeeeeeee.

.eeeeee**eeeeeee eeeeeeeeeeeeeeeeeeeeeeee 12

  • 1.1140
  • 1.3600
  • 1.2870
  • 1.3690
  • 1.2690
  • 1.2930
  • 1.0950
  • e.1. 4 07 5. *. 1. 1311. *.1.2 2. 6 9. *. 1. 12 6 8.. *.1.

2 2 6 2. a.1. 2147..*.1. 4218.*

eee.

13

  • 1.2480
  • 1.2970
  • 1.2920
  • 1.2530
  • 1.2980
  • 1.2200 *

.6820

  • e.1 2 47 3. *. 1. 216 4. *.1.2 27 2.. *.1.

2 57 9. *.1.210 2.. *.1..2 011. *.2.

2 610.

  • 14
  • 1.2490
  • 1.2820
  • 1.2110
  • 1.2440
  • 1.1020 *

.7000

  • e.1. 2426.*.1. 2162..*.1. 2920.*. 1. 257.4.^*eee.4143
  • 2.2013
  • 1 eeeeeeeeeeeeene 15
  • 1.0900 *

.8280 *

.9780 *

.8290

  • F-DEL-H e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.6 0.*.

M-DEL-H

  • 1.4008
  • 1.8447
  • 1.5273
  • 1.84..

AT 100% POWER, 150 BFPD C

B A

e...H.........G.........F.........E.........D. e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e 8*

.9160

  • 1.3140
  • 1.2500
  • 1.3720
  • 1.1300
  • 1.2810
  • 1.1830
  • 1.0140 *
1. 1011.*.1. 3628.*. 1 2057..*.1 2818..*.1. 4633..*
  • 1.7192
  • 1.1685
  • 1.2405
  • e eeeeeeeeeeeeeeeeeeeeeeeeee...

9

  • 1.3140
  • 1.1090
  • 1.3810
  • 1.2660
  • 1.3740
  • 1.2540
  • 1.2460 *

.7620 *

  • 1 1685.*. 1. 4164.*.1. 1038.*.1. 2310
  • 1.1094.*. 1. 2317..*. 1. 2265.*. 1 9088.*..

e..

e**e ee....

10

  • 1.2580
  • 1.3820
  • 1.2870
  • 1.3800
  • 1.2620
  • 1.2950
  • 1.1430 *

.9140

  • 1.2405
  • 1.1030
  • 1.2139
  • 1.1084
  • 1.2417
  • 1.2072
  • 1.3218
  • 1.5670
  • eeeeeeeeee**eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee-11
  • 1.3720
  • 1.2670
  • 1.3880
  • 1.1420
  • 1.3690
  • 1.1880
  • 1.1580 *. 7510 *

. 1 1011..*.1. 2291..*.1. 1068.*.1. 3834.*. 1. 1269..*. 1 2776.*. 1. 3012..*. 1. 9465.*.

e 12

  • 1.1300
  • 1.3790
  • 1.2670
  • 1.3720
  • 1.1960
  • 1.2250 *

.9850 *

  • 1 3628
  • 1.1054
  • 1.2377
  • 1.1245
  • 1.2509
  • 1.2312
  • 1.5048
  • mee seesessenessemeneaseeeeeeeeesesaaaaaaaaaaaaaaaaaaaea.aea**e*

13

  • 1.2810
  • 1.2590
  • 1.3000
  • 1.1920
  • 1.2290
  • 1.0950 *

.6350

  • l

. 1. 2057..*.1. 2278..*. 1. 2034.*. 1. 2744.*. 1. 2280.* 1. 3593..*. 2. 2936.*.

l i

14

  • 1.1830
  • 1.2470
  • 1.1450
  • 1.1610 *

.9920 *

.6470

  • i I
  • 1.2818
  • 1.2256
  • 1.3195
  • 1.2984
  • 1.4990
  • 2.2530
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 15
  • 1.0140 *.7620 *

.9150 *

.7530

)

. 1. 4633..*.1. 9088.*. 1. 5653..*. 1. 9420..* M-DEL-H i

f

Catawba 2 Cycle 7 Core Operating Limits Report Page 137 of 144 Appendix A TABLE 5 (CONTINUED)

F-DEL-H & M-DEL-H VALUES - NORMAL OPERATION AT 100% POWER, 415 BFPD j

e... H......... G......... F......... E...... D......... C... e e e e e e e e ee e.... A......

B es 8*

.9980

  • 1.3170
  • 1.2200
  • 1.3440
  • 1.1010
  • 1.2530
  • 1.1190 *

.9850 *

. 1. 5075..*.1. 1375.*. 1. 2411..*. 1. 0929..*.1 3508..*. 1. 187.4.*.1. 3089.*.1. 4621.*

1.3170

  • 1.1170
  • 1.3460
  • 1.2210
  • 1.3180
  • 1.1800
  • 1.1810 *

.7530

  • 9
  • eeeeeeeeeeeeeeeeeeeeeeee 1. 9121.*.

1.2518

  • e.1. 1375.*. 1. 2691.*. 1. 1047.*.1. 2357..*eee.1147
  • 1.2628
  • 1

. ee.

. e 10

  • 1.2280
  • 1.3460
  • 1.2340
  • 1.3390
  • 1.1990
  • 1.2500
  • 1.0830 *

.9150 *

  • 1. 2 411.. +.1.10 5 0. *. 1. 2 2 8 0. e
  • e e e.112 4. *.1.

2 7 21. *. 1. 219 2.. +. 1. 3 7. 5 2. *.1.

5 4 4 0. *.

1

. e e..

11

  • 1.3440
  • 1.2210
  • 1.3390
  • 1.1030
  • 1.2970
  • 1.1270
  • 1.1150 *

.7500

  • 1.0929
  • 1.2356
  • 1.1118
  • 1.3837 *<1.1471
  • 1.3454
  • 1.3617
  • 1.9581
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 12
  • 1.1010
  • 1.3210
  • 1.2000
  • 1.2900
  • 1.1320
  • 1.1750 *- 9530
  • e 1 3508..*.1. 1107..*. 1. 2702...*.1. 1462
  • 1.2869.* 1.2835
  • 1.5431 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.2530
  • 1.1810
  • 1.2500
  • 1.1270
  • 3.1760.* 1.0440 *

.6650 *

  • 1.1874
  • 1.2616
  • 1.2180
  • 1.3449
  • 1.2825
  • 1.4060
  • 2.1710
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.-

14

  • 1.1190
  • 1.1800
  • 1.0830
  • 1.1150 *

.9540

  • 6720
  • e.1. 3089..*.1. 2517..*. 1. 3750..*.1. 3616
  • 1.5416
  • 2.1507
  • eeeeeeeeeeeeeeeeeeeeee.

15 *

.9850 *

.7520 *

.9140 *

.7500

  • 1.4621.*eee.9128
  • 1.5444
  • 1.9585
  • M-DEL-H 1

eeeeee. e eeeeeeeeeeeeeeeeeee...

AT 75% POWER, 4 EFPD H

G E

D C

B A

  • eeeeeeeeeeeeeeeeeee..F.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.7720

  • 1.2210
  • 1.2370
  • 1.3520
  • 1.1290
  • 1.2720
  • 1.2730
  • 1.1060
  • 2.3822
  • 1.5884
  • 1.6231
  • 1.44..41.*. 1 7512..*.1. 5498.*.1. 5478.*ee 7461.*e 1
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeee.

9

  • 1.2210
  • 1.0550
  • 1.3560
  • 1.2730
  • 1.3750
  • 1.3110
  • 1.3030 *

.8360

  • 1 1.5135
  • 2.2928
  • e 1. 5 8 8 4. *.1.8 8 2 8.*.1. 4 4 91.*.1. 5 8 01. e *e.1.

4 2 9 4. *e e e e. 5 2 0 0

  • eeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.2370
  • 1.3570
  • 1.2940
  • 1.3740
  • 1.2930
  • 1.3040
  • 1.2210 *

.9810 *

  • 1. 6231..*. 1. 4.400..*. 1. 5490.*. 1 4155.*. 1. 54.50..*. 1. 5486.*. 1. 6351.*.1. 9448..*.

e.

11

  • 1.3520
  • 1.2780
  • 1.3780
  • 1.1490
  • 1.3680
  • 1.2430
  • 1.2370 *

.8220 *

  • e. 4 4 41. *. 1. 57 3 8. *. 1. 4113.. *. 1. 7 2 2 0.. *. 1. 4 2 01. *. 1. 5 8 37.. *. 1. 5 8 9 8.. *. 2. 37 7 7.. *
  • 1....

12

  • 1.1290
  • 1.3840
  • 1.3020
  • 1.3730
  • 1.1500
  • 1.2520
  • 1.0760 *
  • 1 7512.*.1. 4221..*. 1. 5377..*. 1. 4159
  • 1.5348
  • 1.5223
  • 1.8012
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.2720 a 1.3180
  • 1.3110
  • 1.2500
  • 1.2580
  • 1.1680 *

.6550 *

  • 1 5498..*. 1.5156..*. 1. 5405.*.1. 5773..*.1. 5153..*. 1. 6147.*.2. 7719..*

es ee.

e 14

  • 1.2730
  • 1.3050
  • 1.2260
  • 1.2440
  • 1.0840
  • 6730
  • e.1. 5 47 8.. *.1.510 2.. *. 1. 6 3 0 0.. *. 1 5 8 21. *. 1. 7 8 9 8. *. 2. 7 018..
  • 15
  • 1.1060 *

.8360 *

.9840 *

.8260

  • 1. 7461.*.2. 2956.*. 1. 9411..*.2. 3661.* M-DEL-H e.

e e

+

w e

y v-sy-.a wn v-

+

yy'~-9 y 9 -

Catawha 2 Cycle 7 Core Operating Limits Report Page 133 of 144 Ap;pendix A TABLE 5 (CONTINUED)

F-DEL-H & M-DEL-H VALUES - NORMAL OPERATION l

AT 754 POWER, 150 EFPD G

F E

C B

A

....H..... eeeeeeeeeeeeeeeeeeeeeeeeeeee..D.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8450

  • 1.3240
  • 1.2850
  • 1.4080 *.1.1540
  • 1.3110
  • 1.2110
  • 1.0310
  • e. 2. 07 9 4. *.1.4 3 4 0.. *.1.

47 8 5. *.1.3 018.. *.1.5 9 67.. *. 1. 413 2.. *. 1. 4 8 9 7.. *.1.

7.14 8. *.

j

  • 1.2730 *

.7710

  • 1.3240
  • 1.1170
  • 1.4150
  • 1.2950
  • 1.4050
  • 1.2900 9 *

. 1. 4 3 4 0.. *.1 7 216.. *.1. e. 3 2 2 0.. *.1.

4 5 47...*.1.

3.119.. *.1.4...... 1. 4368.*.2. 2832..*

j en.

10

  • 1.2850
  • 1.4160.* 1.3140
  • 1.4140
  • 1.2830
  • 1.3200
  • 1.1570
  • 9190
  • e.1. 47 8 5. *. 1. 3 210
  • 1. 4 4 4 3
  • 1. 3 2 6 4
  • 1. 4 8 5 0
  • 1. 4 3 9 0 * - 1. 5 8 7 6
  • 1. 8 9 51 *

...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11

  • 1.4080
  • 1.2960
  • 1.4150
  • 1.1460
  • 1.3720
  • 1.1780
  • 1.1580 *

.7470

  • e.1. 3010.*. 1 4524.*. 1. 3236.*.1 6.616..*.1 3558
  • 1. 5728
  • 1.6140
  • 2.4277 *

...ee.

. eeeeeeeeeeeeeeeeeeeen

.9600

  • 12
  • 1.1540
  • 1.4100
  • 1.2880
  • 1.3760
  • 1.0790
  • 1.1660
  • 1.5967..*.1. 3038..*.1 4792..*.1. 3529..*..'1. 5390.*. 1 5197..*. 1 8782..
    • ee 13
  • 1.3110
  • 1.2840
  • 1.3250
  • 1.1820
  • 1.1700
  • 1.0250
  • 6000
  • e.1. 4132..*. 1. 4418..*. 1. 4326.*.1 5685
  • 1.5153
  • 1.6884
  • 2.8989

.....eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2110
  • 1.2750
  • 1.1600
  • 1.1620 *

.9650 *

.6120

  • ee. 4897..*.1. 4346 *ee....1. 5848
  • 1.6099
  • 1.8703
  • 2.8465 *
  • 1

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeese 15

  • 1.0310 *

.7710 *

.9200 *

.7480

  • 1.7148
  • 2.2833
  • 1.8930
  • 2.42 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.12..* M-DEL-H i

AT 75% PuMER, 415 BFPD H

0 F

B D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee i

6*

.9010

  • 1.3200
  • 1.2660
  • 1.4030
  • 1.1440
  • 1.3090
  • 1.1670
  • 1.0210
  • e.1. 8 57 0. *. 1 3 813.. *. 1. 4 6 0 0...*.1 2 7. 41. *.1.

5 4 3 3.. *.1.

3 6 4 2.. *.1.

5 0 0 5

  • 1. 6 9 9 6
  • eeeeeeeeeeeeee.

9

  • 1.3280
  • 1.1320
  • 1.3940
  • 1.2660
  • 1.3710
  • 1.2210
  • 1.2270 *

.7770 *

  • 1 3 813.. *. 1. 6 2. 4 9.. *.1.

2 9 9 8. *. 1. 4 2 2 2.. *. 1. 3 0 3 0.. *. 1. 4 5 0 0.. *.1.

4 4 21.. *. 2. 2 216.. *.

10

  • 1.2660
  • 1.3940
  • 1.2730
  • 1.3840
  • 1.2290
  • 1.2820
  • 1.1080 *

.9340 *

  • 1 4600..*. 1. 2998.*. 1. 4198.*.1. 3118..*.1. 4704.*.1. 4127..*. 1. 5950.*.1. 8145.*

11

  • 1.4030
  • 1.2660
  • 1.3850
  • 1.1100
  • 1.2950
  • 1.1050
  • 1.1160 *

.7510

  • e.1. 2 7 41. *.1.4 2 2 0.. *. 1. 310 8
  • 1. 6 5 0 8. *. 1. 4 0 27.. *.1.

616 0.. *. 1 6. 3 3 4. *. 2. 3 3 8 8. *.

12

  • 1.1440
  • 1.3760
  • 1.2300
  • 1.2960
  • 1.0040
  • 1.0740 *

.9120

  • e.1 5.433..*. 1. 2978
  • 1.4678
  • 1.4026
  • 1.5711
  • 1.5532
  • 1.9304 *

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13

  • 1.3090
  • 1.2220
  • 1.2820
  • 1.1060
  • 1.0760 *

.9260 *

.6120

  • e.1 3642.*. 1. 4468
  • 1.4119
  • 1.6145
  • 1.5513
  • 1.7467 2.7683 *

.. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.1670
  • 1.2260
  • 1.1000
  • 1.1160 *

.9130 *

.6100 *

. 1. 5005..*.1. 4428 *.... 1. 5947..*. 1. 6331..*.1.9274

  • 2.7396 *

. eeeeeeeeeeeeeeee.

15 *-1.0210 *

.7770 *

.9340 *

.7500

  • 1.6996
  • 2.2215
  • 1.8149
  • 2.33 M-DEL-H e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e.00..*e

Catawha 2 Cycle 7 Core Operating Limits Report Page 139 of 144 Appendix A TABLE 5 (CONTINUED)

F-DEL-H & M-DEL-H VALUES - NORKAL OPERATION AT 50% POWER, 4 EFPD H

G F

B D

C B-A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

8*

.7440

  • l'.2260
  • 1.2500
  • 1.3790
  • 1.1450
  • 1.2970
  • 1.2990
  • 1.1200
  • 5.*. 2. 0.168.*.2. 4171
  • 2.1574
  • 2.1423
  • 2.4590.*
  • 3.2900
  • 2.2233
  • 2.206

.eeeeeeeeeeeeeeeeeeeeeeeeeeeee..

eeeeeeeeeeeeeeeeeeeeeeen.

9

  • 1.2260
  • 1.0590
  • 1.3820
  • 1.2970
  • 1.3900
  • 1.3340
  • 1.3270 *

.8430'*

  • 1.9272
  • 2.0687
  • 2.0907
  • 3.2368
  • e.2. 2233..*.2. 5739
  • 2.0054
  • 2.1294

. eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee ee 10

  • 1.2580
  • 1.3840
  • 1.3140
  • 1.3960
  • 1.3100
  • 1.3240
  • 1.2350 *

.9840 *

. 2. 2065.*.2. 0024.*.2. 0812..*. 1. 9141..*.2. 0776..*.2. 0885.*.2. 2014

  • 2.6813
  • eeeeeeeeeeeeeee 11
  • 1.3790
  • 1.3020
  • 1.4040
  • 1.1470
  • 1.3690
  • 1.2390
  • 1.2333 *

.8180

  • 9137
  • 2.1239
  • 2.1422
  • 3.2381 *
  • 2.0168
  • 2.1209
  • 1.9085
  • 2. 3215
  • 11 eeeeeeeeeeeeeeeeeeeeeeeeeeeee

.eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.1450
  • 1.4070
  • 1.3190
  • 1.3750
  • 1.0990
  • 1.2090
  • 1.0540
  • 2.4171
  • 1.9160
  • 2.0665
  • 1.9066
  • 2.0544
  • 2.0413
  • 2.4293
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13
  • 1.2970
  • 1.3410
  • 1.3330
  • 1.2460
  • 1.2150
  • 1.1110 *. 6270 *
  • 2.1574
  • 2.0576
  • 2.0789
  • 2.1141
  • 2.0323
  • 2.1682
  • 3.9237
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 14
  • 1.2990
  • 1.3310
  • 1.2400
  • 1.2400
  • 1.0620 *

.6450

  • 2.1423
  • 2.0858
  • 2.1943
  • 2.1321
  • 2.4121
  • 3.8177
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.1200 *

.8430 *

.9870 *

.8220

2 408

  • 2. 67 58
  • 3.222 4
  • M-DEL-H
  • 2.459

...eeeeeeeeeeeeeeeeeee.

AT 50% POWER, 150 EFPD G

F E

B A

e e e e e e e e e e e e e e e e e e e e e e e e e e e e........D.........C e...H seeeeeeeeeeeeeeeeeeeeeee 8*

.7880

  • 1.3370
  • 1.3270
  • 1.4650
  • 1.1950
  • 1.36.10
  • 1.2200
  • 1.0480 *
  • 2. 8071.*. 1. 9480..*.2. 0049.*. 1. 7931
  • 2. 1912..*.1. 9282
  • 2.0520.*. 2. 3964.*.

e.

e**ee.

eeeeeeeeee,.

9

  • 1.3370
  • 1.1290
  • 1.4500
  • 1.3400
  • 1.4540
  • 1.3210
  • 1.3140 *

.7830 *

  • 1.9480
  • 2.3013
  • 1.8181
  • 1.9717
  • 1.8055
  • 1.9790
  • 1.9700
  • 3.2002
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee<

eeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.3270
  • 1.4590
  • 1.3210
  • 1.4570
  • 1.3160
  • 1.3600
  • 1.1840 *

.9330

  • e.2 0 0 4 9 e *.1.

815 5. *. 1. 9 3 7 5

  • 1. 8 0 6 3. *.1 9 7 2 9. *. 1. 9 4 5 3. *.2.

17 6 3.. *. 2. e. 7 07 4 *

. e

. eeeeeee....

eeee.

11

  • 1.4650
  • 1.3420
  • 1.4500
  • 1.1500
  • 1.3700
  • 1.1680
  • 1.1630 *

.7490

  • e.1 7 9 31. *.1 9 6 8 6. *. 1. 8 0 6 3. *.2.

19 61

  • 1. 8 2 4 4
  • 2. 07 8 9
  • 2.1519
  • 3. 3 314
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

12

  • 1.1950
  • 1.4640
  • 1.3220
  • 163740 *

.9920

  • 1.0720 *

.9240 *

  • 2.1912
  • 1.7932
  • 1.9651
  • 1.8203
  • 2.0314
  • 2.0155
  • 2.5186
  • eeeeeeeeeeeeeee*eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3610
  • 1.3270
  • 1.3660
  • 1.1720
  • 1.0760 *

.9130 *

.5550 *

  • 1.9282
  • 1.9716 1 1.9363
  • 2.0720
  • 2.0090
  • 2.2552
  • 3.9350 *
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**eeeeee**ee 14
  • 1.2200
  • 1.3160
  • 1.1870
  • 1.1660 *

.9280 *

.5670 *

  • 2.0510
  • 1.9671
  • 2.1705
  • 2.1462
  • 2.5082
  • 3.8570
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

15

  • 1.0480 *

.7830 *

.9340 *

.7510

  • F-DEL-H eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.65.*. N-DEL-H 2.3964
  • 3.2002
  • 2.7048
  • 3.32..

Catawba 2 Cycle 7 Core Operating Limits Report Page 140 of 144 4

Appendix A s

~

TABLE 5 (CONTINUED) 9-DEL-H tr M-DEL-H VALITMS

.- NORMAL OPERATION AT 50% POWER, 415 EFPD H

O P

R D

C B

A eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 8*

.8330

  • 1.3330
  • 1.3000
  • 1.4690
  • 1.1880
  • 1.3530
  • 1.1270 *

.9800

  • j 5 2 7.. *..?. 2 5 67.. *e

...... 8149

  • 1e.8340
  • 1.e.6306 *ee....1. 9893..*.1. 7584
  • 1.9

. 2. 3968 1.eeeee.

ee e

...ee ee.eee.e.

9

  • 1.3330
  • 1.1210
  • 1.4300
  • 1.3050
  • 1.4340
  • 1.2650
  • 1.2480 *

.7550

  • 1.6745
  • 1.8738
  • 1.8812
  • 2.9527
  • e.1. 814 9. *. 2. 0 9 8 4. *.1 6 6 91. *.1.

8111..e

... eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 10

  • 1.3000
  • 1.4300
  • 1.1780
  • 1.4090
  • 1.2650
  • 1.3280
  • 1.1390 *

.9480

  • 1.8340
  • 1.6695
  • 1.8154
  • 1.6842
  • 1.8975
  • 1.0037'* 2.0760
  • 2.4865
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 11
  • 1.4690
  • 1.3050
  • 1.4110
  • 1.1010
  • 1.3030
  • 1.1160
  • 1.1410 *

.7660

  • 1.010...een8.*.1.6828.* 2.1545..*.1.e.8337
  • 2. 1026
  • 2.0427
  • 2 9646 *
  • 1.6306 *

.. eeeee eeeee..

eeeeeeeeeeeeeeeee

...ee q'

eseeeeeeeeeeeee.

12

  • 1.1880
  • 1.4410
  • 1.2670
  • 1.3040 *

.9370

  • 1.0190 *

.9040 *

  • 1.9893..*eee.6667eeeeee.1. 8931
  • 1.8322
  • 2.0624
  • 2.0529
  • 2.5568
  • 1 eeeee..

..eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.3530
  • 1.2660
  • 1.3290
  • 1.1170
  • 1.0210 *

.8560 *

.5860 *

  • e e. 5 8 4. *.1.

8 6 9 0.. *.1 8 018...*.2.

0 9 8 5.. *. 2. 0. 4 9 4. *. 2. 3 2 61.. *. 3. 7 47 4. *

  • 1.7 14
  • 1.1270
  • 1.2480
  • 1.1190
  • 1.1410 *

.9050 *-.5950

  • 1. 9527..*ee. 8819..*.2. 0736..*.2. 0420
  • 2. 5511.*. 3. 7073.*

1 e.

e eeee.

15 *

.9800 *

.7550 *

.9480 *

.7660

. 2. 2567..*.2. 9561.*.2. 4865.*.2. 9632..*. M-DEL-H 1

3 1

1 1

i t

e 6

i i

2

?

i l

T

I J

Catawba 2 Cycle 7 Core Operating Limits Report Page 141 of144 Appendix A TABLE 6 F-DEL-H E M-DEL-H VALUES - POWER ESCALATION AT 100% POWER,

'4 EFPD A

.... H........ 0....... F......... E......... D......... C......... B..... e e e e e e e e e.

8 *

.8240

  • 1.2170
  • 1.2190
  • 1.3280
  • 1.1150
  • 1.2490
  • 1.2500
  • 1.0920
  • e.1 8. 4 8 2.. *..1 2 4 8 3. *.1.

2 8 5 6. *.1.15 4 4. *. 1. 4 07 5.. *. 1. 2 47 3.*.

1. 2 4 2 6. e *e.1 4 0 0 8. *.

.ee 9

  • 1.2170
  • 1.0530
  • 1.3320
  • 1.2520
  • 1.3530
  • 1.2910
  • 1.2800 *

.8300 *

  • 1. 2 4 8 3. *.1.47 6 4. *.1.1514. e *e e e e. 2 5 6 3...*.1 13 6 0. *.1.

2 2 01..*.1.210 0.

  • e e e. 8 4 2 6
  • 1 1

e ee....

e.e eeeeen 10

  • 1.2190
  • 1.3330
  • 1.2770
  • 1.3650
  • 1.2810
  • 1.2850
  • 1.2080 *

.9760

  • e.1. 2856.*. 1. 1505.*. 1. 2314.*.1. 1282.*.1. 2327..*.1. 2330..**1.2952
  • 1.5320 *
  • eeeeeeeeeeeeeee.

11

  • 1.3280
  • 1.2570
  • 1.3690
  • 1.1530
  • 1.3640
  • 1.2470
  • 1.2380 *

.8260

  • eeeeeeeeeeeeeqeeeaee. 1257..*.1 3685
  • 1. 1292..*.1 2629
  • 1.2626
  • 1.8549 *
  • 1.1544
  • 1.2523
  • 1

... eeeeee.

eeeeeeeeeeeeeeeeeeeeee.

12

  • 1.1150 *- 1.3610
  • 1.2870
  • 1.3690
  • 1.2600
  • 1.2890
  • 1.0940 *
  • e e 4 07 5. *. 1. 1311.. *.1.2 2 6 9. *.1.12 6 8. *. 1. 2 2 6 2.. *. 1. 2147.. *. 1. 4 218.. *
  • 1 13
  • 1.2490
  • 1.2980
  • 1.2930 e 1.2520
  • 1.2950
  • 1.2160 *

.6810

  • e.1. 2. 47 3.. *.1.

216 4. *. 1. 2 27 2.. *.1.

2 57 9. *.1.2102.. *.1 2 811.. *.2.2 610. *.

14

  • 1.2500
  • 1.2830
  • 1.2120
  • 1.2440
  • 1.1010 *

.6990 *

=

  • 1. 2426.*.1. 2162..*. 1. 2920.*.1. 2.574.*. 1. 4143..*.2. 2.013..*

e.

15

  • 1.0920 *

.8290 *

.9790 *. 6300

. 1. 4008.... 1 8447.*.1. 5273..*.2 8460

  • M-DEL-H

. 2 eeeee.

AT 75% POWER, 4 EFPD e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e....C.........B....eeeeeeeee..

H G

F E

D A

8*

.7970

  • 1.2160
  • 1.2270
  • 1.3370
  • 1.1160
  • 1.2550
  • 1.2560
  • 1.0890
  • e. 2. 3 82 2.. *. 1. 5 8 8 4. *. 1. 62 31.. *.1. 4 4 41.. *. 1. 7 512.. *.1.
5. 4 9 8. *.1 5 4 7 8. *.1.7 4 61 *e

.. eee.

....... eeeeee W

  • 1. 216 0
  • 1. 0 4 9 0
  • 1. 3 450
  • 1. 2 63 0
  • 1. 3 6 50
  • 1. 3 0 0 0
  • 1. 2 87 0 *

.8240

  • e.1. 5884.*.1. 8828
  • 1.e.4491
  • 1.5801
  • 1. 4294.*.1. 5200
  • 1.5135
  • 2 2.928.*.

ee.... eeeeeeeeeeeeeeee eeeeeeeeeeeeee.

10

  • 1.2270
  • 1.3460
  • 1.2870
  • 1.3730
  • 1.2880
  • 1.2950
  • 1.2120 *

.9700

  • 7
  • 1. 6231
  • 1. 4 4 8 0
  • 1. 5 49 0.e *e e e e.415 5
  • 1. 5 4 50
  • 1. 5 40 6
  • 1. 63 51
  • 1. 9 4 a n e 1

e.eeeeeeeeeeeeeeeee.

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

11

  • 1.3370
  • 1.2680
  • 1.3780
  • 1.1940
  • 1.3720
  • 1.2510
  • 1.2400 *

.8h 1.4441

  • 1.57...38.*.1. 4113.*.1 7220..*. 1 4201.*. 1. 5837..*. 1. 5898..*. 2. 3777...*

eeeeeeee.** ee.

12

  • 1.1160
  • 1.3730
  • 1.2960
  • 1.3770
  • 1.2430
  • 1.2870
  • 1.0880 *-

.. ** 12.*e*1.,4221.*. 1. 5377..*. 1. 4159

  • 1.$348
  • 1.5223 = 1.8012 *
  • 1.75..

i

.eeeeeeeeesesseeeeeeeeeeeeeeeeee i

13

  • 1.2550
  • 1.3070
  • 1.3020
  • 1.2570
  • 1.2930
  • 1.2080 *

.6690 *

  • 1. 5498
  • 1. 5156..*. 1. 5405.*.1 5773..*. 1. 5153..*. 1. 6147..*.2. 7719..*.
  • e 4

14

  • 1.2560
  • 1.2900
  • 1.2170
  • 1.2470
  • 1.0960 *

.6880

  • l e.1. 5478 *.. e e. !.10 2.. *. 1. 6 3 0 0.. *. 1. 5 8 21.*.
1. 7 8 9 8.. *. 2. 7 018.. *.

1 15

  • 1.0890 *

.82hd *.9730 *

.8220

. 1. 7461..*. 2. 2956

  • 1. 9411..*. 2. 3661..* M-DEL-H I

l' l

l I

i I -

l l

l 1

i i

1 Catawba 2 Cycle 7 Core Operating Limits Report Page 142 of 144 Appendix A TABLE 6 (CONTINUED)

'F-DEL-H & M-DEL-H VALUES - POWER ESCALATION AT 50% POWER, 4 EFPD

....H........ 0.........F......... E.. e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e e... A...

D C

B 8*

.7930

  • 1.2140
  • 1.2330 1.3440
  • 1.1150
  • 1.2570
  • 1.2570'*.1.0800 *-
  • 3 2900..*. 2. 2233.*.2. 2065..*. 2. 0168.*. 2. 4171..*.2. 1574..* 2. 1(23.*.2. 4590..*.

e..

9

  • 1.2140 *'1.0450
  • 1.3570
  • 1.2730
  • 1.3740
  • 1.3060
  • 1.2900 *

.8150 *

... 2233..*.2. 5739.*.2. 0054

  • 2.1294 *.1.9272
  • 2.0687
  • 2.0907
  • 3.2368 *
  • 2

... eeeeeeeeee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

10

  • 1.2330
  • 1.3590
  • 1.2980
  • 1.3820
  • 1.2970
  • 1.3030
  • l'2130 *

.9610 *

  • -2. 2065.*. 2. 0024.*.2. 0872..*.1. 9141.*.2. 0776..*. 2. 0885.*. 2. 2014.*. 2. 6813..*.

e.

11

  • 1.3440
  • 1.2790
  • 1.3870
  • 1.1550 *-1.3810
  • 1.2580
  • 1.2410 *

.8090 *'

  • 2.1209
  • 1.9005
  • 2.3215 *
  • 3.2381
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee**e.1.9137
  • 2.1239
  • 2.1422 e.2.0168 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...

12

  • 1.1150
  • 1.3830 *'1.3050
  • 1.3870
  • 1.2470
  • 1.2930
  • 1.0850 *
  • 2.4171 *,1.9160
  • 2.0665
  • 1.9066..*. 2. 0544.*.2. 0413.*.2. 4293.*.
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

13

  • 1.2570.* 1.3140
  • 1.3110
  • 1.2650
  • 1.3000
  • 1.2000 *

~.6600

  • 3 e.2. 1574
  • 2.0576
  • 2.0789
  • 2.1141..'..'2. 0323..*.2. 1682..*.s 9237..*e 6

. eeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2570'* 1.2930
  • 1.2180
  • 1.2490
  • 1.0930 *

.6790

  • e.2. 1423..*. 2. 0858..*.2. 1943.* 2. 1321
  • 2.4121
  • 3.8177 *

.eeeeeeeeeeeeeeeeeeeeee.

15

  • 1.0800 *

.8140 *

.9640 *

.8130

  • 2.6758
  • 3.2224
  • M-DEL-H
  • 2.4590
  • 3 *eeeeeeeeeeeeeeeeee ee.

AT 30% POWER, 4 BFPD

....H.........Q.........F........E.........D.................B.........A......

'^

C

.7720

  • 1.2150
  • 1.2400
  • 1.3520
  • 1.1140
  • 1.2570
  • 1.2550
  • 1.0710
  • B
  • 3.2900 2.2233
  • 2.2065
  • 2.0168
  • 2.4171
  • 2.1574
  • 2.1423
  • 2.4590
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeene 9
  • 1.2150
  • 1.0440
  • 1.3700
  • 1.2830
  • 1.3850 *-1.3110
  • 1.2910 *

.8050

. 2. 2233.*.2. 5739.*..2. 0054.*. 2. 1294.*. 1. 9272..*.2. 0687..'*.2. 0907..*.3 2368.*-

10

  • 1.2400 *'1.3720
  • 1.3080
  • 1.3910
  • 1.3030
  • 1.3090
  • 1.2130 *.9520 *

. 2. 2065.*.2. 0024.*. 2. 0872..*.1. 9141.*.2. 0776..*.2. 0885

  • 2. 2014.*.2. 6813..*..

11

  • 1.3520
  • 1.2390
  • 1.3960
  • 1.1560
  • 1.3890
  • 1.2630
  • 1.2410 *

.8000 *

  • 2. 016 8
  • 2. 12 0 9. *.1. 9 0 8 5.*.2. 3 215..*. 1. 9137..*.2.12 3 9.*.2. 1. 42 2..*.3.2 3 81.. *e e.

12

  • 1.1140
  • 1.3930 e 1.3120
  • 1.3960
  • 1.2510
  • 1.2900 1.0810 *

-j 1.9160

  • 2 e e...+.*
  • e **

e.. 066 5

  • 1. 9 0 66
  • 2. 054 4'
  • 2. 0 413
  • 2. 42 9 3 *.

e...

171 *

  • 2.4

.eeeeeeeesssesseseeseesesseseaseeeeeeeeee.

13

  • 1.2570
  • 1.3190
  • 1.3180
  • 1.2700
  • 1.3040
  • 1.2060 *

.6520 *

. 2. 1574.*.2. 0576.*. 2. 0789..*. 2. 1141

  • 2.0323
  • 2.1682
  • 3.9237
  • eeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.

14

  • 1.2550
  • 1.2950
  • 1.2180
  • 1.2480
  • 1.0890 *

.6710 *

  • 2. 1423.*. 2. 0858 **2.1943
  • 2.1321.*. 2. 4121..*. 3. 8177..*.

ee..

  • eeeeeeeeeeee.

15

  • 1.0710 *

.8050 *

.9560 *. 8050

... 4 5 9 0..*.3. 2 4 08

  • 2. 67 5 8.* 3. 2 22 4
  • M-DEL-H
  • 2 I

I I

l A

I h

i i

Catawha 2 Cycle 7 Core Operating Limits Report Page 143 of144 Appendix A Table 7 Maximum Allowable Radial Peaks (MkRPS) for Non. Axial Blanket Fuel l

Core Heiaht 1.1 Arial 1.2 Arial 1.3 Azial 1.4 Arial ift)

Peak Peak 21&%

Esak l

M M&BE MARP M

0.12 1.5809' 1.6266 1.6722 1.7113-1.2 1.5806 -

1.6259 1.6677 1.7085 l

2.4 1.5836 1.6265 1.6663 1.7025 3.6 1.5859 1.6263 1.6635

-1'.6960 4.8 1.5871.

1.6240 1.6571 1.6751.

6.0 1.5878 1.6196 1.6470 1.6303 7.2 1.5864 1.6130 1.6265 1'5848 l

8.4 1.5781 1.5956 1.5773 1.5327 l

9.6 1.5655 1.5612 1.5208 1.4815 l

~10.8 1 5459 1.5152 1.4717 1.4292 12.0 1.5133 1.4693 1.4274 1.3878_

Core Meicht 1.5 Arial 1.6 Arial-1.7 Arial 1.8 Arial ift)

Peak Engk Peak Ettk M&BE M&RE M&BE M&RE 0.12 1.7477

.1.7331 1.7054 1.643w l

1.2 1.7433 1.7029.

1.6789 1.6193 2.4 1.7126 1.6616 1.6433 1.5869 i

3.6 1.6735 1.6211 1.6011-

'1.5504

~

l 14.8 1.6313 1.5811 1.5622 1.5121 l

6.0 1.5868 1.5415 1.5238 1.4763 7.2 1.5378 1.4913 1.4766

.1.4344 8.4 1.4886 1.4450 1.4296 1.3880 E

9.6 1.4399 1.4013 1.3882 1.3490 10.8 1.3883 1.3526-1.3433' 1.3081 12.0 1.3500 1.3140' 1.3078 1.2749 Core Heicht 1.9 Arial 2.1 Axial ifti Etak 22ak MARP MARE 0.12 1.5839 1.5401 i

1.2 1.5624 1.5154 2.4 1.5328 1.4801 3.6 1.5013 1.1395 4.0 1.4626 1.4030 l

6.0 1.4291 1.3619 5

7.2 1.3920 1.3271 8.4 1.3485 1.2824t 9.6 1.3126 1.2501.

1 l

10.8 1.2726 1.2091 l

12.0 1.2443 1.1890 l

l l'

l i

l.

l

I Catawba 2 Cycle 7 Core Operating Limits Report.

Page 144 of 144 Appendix A q

Table 8

- Maximum Allowable Radial Peaks (MARPS) i for Axial Blanket Fuel Core Heicht 1.1 Arial 1.2 Arial 1.3 Arial 1.4 Arial fft)

Peak E3Ah Emah Peak MARP MARP H&EE H&EE 0.12 1.5491 1.5942 1.6385 1.6771 1.2 1.5491 1.5933 1.6346 1.6743-2.4 1.5518 1.5942 1.6331

.1.6686 3.6 1.5545 1.5942 1.6300 1.6621 4.8 1.5555 1.5917 1.6238 1.6414 6.0 1.5564 1.5875 1.6138 1.5979 7.2 1.5545 1.5808 1.5938 1.5529 8.4 1.5464 1.5633 1.5454 1.5021 9.6 1.5345 1.5300 1.4900 1.4521 10.8 1.5145 1.4850 1.4423 1.4007-12.0 1.4827 1.4400 1.3985 1.3600 pore Heicht 1.5 Axial 1.6 Axial 1.7 Axial 1.8 Arial

.LLt;1 Ennh Penk Penk EsAh M&BE MARP H&BE MARP 0.12 1.7127 1.6988 1.7053 1.6439 1.2 1.7087-1.6688 1.6788 1.6194-2.4 1.6787 1.6281