Requests Waiver from Subarticles IWA-4210 & IWA-4240,1974 Edition Through Summer 1975 Addenda of Section XI to ASME Code Re Inservice Insp.Listed Subarticles of 1977 Edition Through Summer 1978 Addenda Contain More Accurate Info
ML20069B886
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 03/14/1983
From: Westafer G
FLORIDA POWER CORP.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
3F-0383-18, 3F-383-18, TAC-49973, NUDOCS 8303170319
Download: ML20069B886 (2)


Text

D 4

{Nfbh) q QCr Ji,

wese.

M Power C O A P O m a t i n es March 14,1983 3F-0383-18 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Relief from ASME Section XI, Articles IWA-4210 and 4240

Dear Mr. Denton:

Presently Florida Power Corporation is required to perform examinations of Class 1, 2, or 3 systems per Section 4.0.5 of the Technical Specifications in accordance with the ASME Boiler and Pressure Vessel Code,Section XI,1974 Edition through Summer 1975 Addenda. Included in these examinations are rules for modifications, replacements, additions, and alterations described in IWA-4240 and required pressure tests of repairs, modifications, replacements, additions, and alterations as described in IWA-4210.

The 1977 Edition through Summer 1978 Addenda clarifies the definitions of the Summer 1975 Addenda of IWA-4240 and reflects accepted industry standards for pressure tests of replacements. This Edition also contains a new article, IWA-7000, not presently contained in the 1974 Edition, which provides the necessary guidelines for the establishment of a well-defined program governing " Replacements" at Crystal River Unit 3.

Therefore, this letter requests that Florida Power Corporation be granted waivers from IWA-4210 and 4240,1974 Edition through the Summer 1975 Addenda of Section XI to the ASME Code. In lieu of these requirements, we wish to adopt Subarticles IWA-4400 and 4600, and Article 7000 of the 1977 Edition through Summer 1978 Addenda of Section XI to the ASME Code. IWA-4210 and 4240 are considered impractical for use at Crystal River Unit 3 as they do not provide sufficient guidelines concerning repairs, modifications, replacements, additions, and alterations on which to establish an ISI Program.

/)ooI w/c/cclt*

}l YooO.OC) 8303170319 830314 PDR ADOCK 05000302 O

PDR General Office 3201 Tnirty-fourth street soutn. P O Box 14042 st Petersburg, Flonda 33733 813-866-5151 f

/

e p

e 3F-0383-18 March 14,1983 l

Florida Power requests that your response be included with previous Inservice Inspection Relief request responses scheduled to be issued by your staff on or about April 29,1983.

Florida. Power Corporation has determined that this relief request involves a Class. III amendment, per 10CFR120.22, in that it involves a single safety issue. Accordingly, the fee of four thousand dollars ($4,000.00) is enclosed.

Sincerely,

, f.

G. R. Westafer Manager Nuclear Licensing and Fuel Management PGH/mm cc:

Mr. 3. P. O'Reilly, Regional Administrator Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, GA 30303 -

Fw-u