ML20069A666

From kanterella
Jump to navigation Jump to search
Forwards TS Change Request 244 to License DPR-50,requesting Revised CR Trip Insertion Time Testing Acceptance Criterion for Remainder of Cycle 10 for 12 Specific CRs Which Experienced Slow Rod Drop Times During Testing on 940317
ML20069A666
Person / Time
Site: Crane Constellation icon.png
Issue date: 05/20/1994
From: Broughton T
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20069A671 List:
References
C311-94-2069, NUDOCS 9405260096
Download: ML20069A666 (2)


Text

1 e

GPU Nuclear Corporation f g Route 441 South of hh hhf P.O. Box 480 Middletown. Pennsylvania 17057-0480 (717)944 7621 Writer's Direct Dial Number:

(717) 948-8005 May 20, 1994 C311-94-2069 U. S. Nuclear Regulatory Commission Att: Document Control Desk Washington, DC 20555

Dear Sir:

Subject:

Three Mile Island Nuclear Generating Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Technical Specification Change Request (TSCR) No. 244 Cycle 10 Control Rod Trip Insertion Time Testing In accordance with 10 CFR 50.4(b)(1), enclosed is Technical Specification Change Request (TSCR) No. 244.

Also enclosed is a Certificate of Service for this request, certifying service to the chief executives of the township and county in which the facility is located, as well as the designated official of the. Commonwealth of' Pennsylvania, Bureau of Radiation Protection.

in accordance with the NRC Confirmatory Action Letter (CAL) of March 29, 1994, GPUN submitted evaluation criteria for control rod drop time testing results-by letter dated April 22, 1994.

In our meeting with the staff on May-3, 1994, we were informed that NRC approval of the evaluation criteria was not likely to occur prior to scheduled drop time testing on June 1, 1994.

In accordance with the April 22, 1994 letter, TSCR No. 244 requests a revised control rod trip insertion time testing acceptance criterion for the remainder of Cycle'10

.for the twelve (12) specific control rods which initially experienced slow rod drop times during. testing conducted on March 17, 1994.

In order to preclude the possible need for future Enforcement Discretion should control rod drop times for any of the specified control rods be greater than 1.66 seconds but less than 2.11' seconds, it is requested that this TSCR be processed under exigent procedtres to support continued TMI-l operation.

. 'i. ' q

?,

NS 940s2600,6 940s20 i

PDR ADOCK 0s000289

.i P

PDR

\\

GPU Nuclear Corporation is a subsidiary of General Pubhc Uthes Corporation

.e Document Control Desk

.. C311'-94-2069' Page 2 of 2

-Pursuant to 10 CFR 50.91(a)(1), enclosed is our analysis, applying the standards in 10 CFR 50.92 to make a determination of no significant hazards

. considerations. As stated above, pursuant to 10 CFR 50.91(a), we have i

provided a copy of this letter, the proposed change in Technical Specifications, and our analyses of significant hazards considerations to Robert J. Barkanic, the designated representative of the Commonwealth of Pennsylvania.

Sincerely,

[ehg )%

d T. G. BrougMon Vice President and Director, TMI DJD/plp

Enclosures:

1) Technical Specifications Change Request No. 244
2) Certificate of Service for Technical Specification Change Request No. 244 i

cc:

Region I Administrator TMI-l Senior Project Manager TMI Senior Resident 1.ispector l'

l I

I l

1 l

L I