Final Deficiency Rept DER-48 Re Dragon Valve Co Instrument Line Check Valves Seized Open by Welding Heat.Movable Internal Poppet for Excess Flow Check Valve Redesigned by Vendor to Preclude Binding from Welding Valve in Place
ML20067D715
Person / Time
Site: Palo Verde 
Issue date: 12/07/1982
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Sternberg D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
10CFR-050.55E, 10CFR-50.55E, ANPP-22459-GHD, DER-82-48, NUDOCS 8212210097
Download: ML20067D715 (3)


Text

Dockst Nos. 50-528/529/53f 50.55(o) Report Arizona Public Service Company

. PHOENIX. ARIZONA 85036 P.o. box 21666 December 7, 1982

'ANPP-22459-GIID/BSK U. S. Nuclear Regulatory Commission Region V-Creekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek, California 94596-5368 Attention:

Mr. D. M. Sternberg, Chief Reactor Projects Branch 1

Subject:

Final Report - DER 32-48 A 50.55(e) Reportable Condition Relating to Dragon Valve Company Instrument Line Check Valves Seized Open by Welding Heat File: 82-019-026 D.4.33.2

Reference:

(A) Telephone Conversation between T. Young and G. Duckworth on September 1, 1982 (B) ANPP-21927, dated September 30, 1982 (Interim Report)

Dear Sir:

Attached, is our final written report of the reportable deficiency, under the requirements of 10CFR50.55(e).

Very truly yours,

. \\ m \\ nu, \\b_.

r E. E. Van Brunt, Jr.

APS Vice President Nuc1 car Projects !!anagement ANPP Project Director EEVBJr/ Gild:db Enclosure N000 cc: See Attached Page 2 fG :l.u 81 330 5 0 G.is 03A0033 8212210097 821207 PDR ADOCK 05000529 s

S PDR

~ ~

.s i,

t.

U. S. Nuclear Regulatory Commission December 7, 1982 Attention:

Mr. D..M. Sternberg, Chief ANPP-22459-GHD/BSK i

Page 2 cc: Richard DeYoung, Director:

Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission

' Washington, D. C. 20555 T. G. Woods, Jr.

J. A. Roedel D. B. Fasnacht G. C. Andognini J. R. Bynum A. C. Rogers i

B. S. Kaplan W.

E.~ Ide J. Vorees J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham i

R. L. Patterson R. W. Welcher i

R. H. Grant D. R. Hawkinson L. E. Vorderbrueggen G. A. Fiorelli P. P. Klute 1-Lynne Bernabei, Esq.

Harmon & Weiss 1725 "I" Street, NW j

Washington, D. C. 20006 R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 37503 i

k I

r l

l

?

I

, - ~

,,,.,,,..-.-.4,#,,..,,---,w,..,--,ve.e,.-,,--,,,-,m.o,

.,,--,.-,,,,n,--.44.-,..-,,,-,,i~...,--.,,,n--,em-wr,

FINAL REPORT - DER 82-48 DEFICIENCY EVALUATION 50.55(e)

ARIZONA PUBLIC SERVICE COMPANY (APS)

PVNGS UNIT 1 4

1.

DESCRIPTION OF DEFICIENCY An installation problem has been encountered with the Excess Flow Check Valves supplied by Dragon Valve Company (PVNGS specification 13-JM-705). Thermal expansion and distortion of the valve body in the heat affected zone during welding assembly with the piping systems causes the poppet to seize in the open position.

II.

ANALYSIS OF SAFETY IMPLICATION This condition is evaluated as Reportable. The condition precludes the device from performing its intended function of preventing loss of fluid in the event of instrument tubing rupture or loss of pressure down stream of the check valve. Should the condition remain uncorrected, and in the event of a tubing rupture, the defect would result in release of radioactive fluids which could present a substantial safety hazard.

III. CORRECTIVE ACTION The movable internal poppet for the excess flow check valve has been redesigned by the vendor to preclude binding as a result of welding the valve in place.

Nonconformance Report PX-4379 will be dispositioned to test and/or rework all the subject flow check valves delivered to the jobsite.

Valves failing an operational test, or not tested, will be reworked by installing the redesigned poppet. The vendor will provide corrected valves for Units 2 and 3 to preclude recurrence of this problem at PVNGS.

In addition to reportability under 10CFR50.55(c), PVNGS Project considers the deficiency to be Reportable under the requirements of 10CFR Part 21 by the supplier. This Deficiency Evaluation Report (82-43) addresses the reporting requirements specified under 10CFR 21.21.(b) (3) with the exception of sub part (vi) which requires the number and location (customers and/or facilities) of other possibly defective equipment. A copy of this report has been sent to Dragon Valve Company requesting their review for reporting under 10CFR Part 21, including number and location of all components supplied.