ML20067D251
| ML20067D251 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 02/04/1991 |
| From: | Skolds J SOUTH CAROLINA ELECTRIC & GAS CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML20067D254 | List: |
| References | |
| GL-90-09, GL-90-9, TSP-910003, TSP-910003-0, NUDOCS 9102130006 | |
| Download: ML20067D251 (2) | |
Text
._
South Carolina Electric & Gas Company Jchn L os Jenk'nsvh SC 29065 Nuclear Operahons (803) 34H040 SCE&G FEB 0 41991
. a_
1 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 Gentlemen:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION DOCKET N0. 50/395 OPERATING LICENSE NO. NPF-12 TECHNICAL SPECIFICATIONS CHANGE - TSP 910003-0 SNUBBERS (GENERIC LETTER 90-09)
In accordance with 10CFR50.90, South Carolina Electric and Gas Company (SCCE&G) is submitting an amendment request to License NPF-12 to change the Technical Specifications (TS) for the Virgil C. Summer Nuclear Station (VCSNS). The proposed amendment is a revision to TT 4.7.7 SNUBBERS SURVEILLANCE REQUIREMENTS and associated BASES 3/4.7.7, in conformance with the guidance provided in Generic Letter (GL) 90-09. Accordingly,- the next visual inspection for VCSNS will be based on the results of previous visual inspections and the criteria of GL 90-09.
The proposed change is needed to reduce occupational dose, reduce the amount of resources used for snubber inspections, and shorten the refueling outage duration.
SCE&G has scheduled a refueling outage to begin in September 1991.
Because of the potential impact on the outage schedule, SCE&G requests that the NRC process.this amendment by May 1, 1991.
The proposed technical specification change is identified in Enclosure 1.
The safety evaluation is provided in Enclosure 2.
A proposed no significant hazards evaluation performed pcrsuant to 10CFR50.92 is provided in.
This proposed technical specification change has been reviewed and approved by the Plant Safety Review Committee and the Nuclear Safety Review Committee.
I declare that the statements and matters set forth herein are true and correct to the best of my knowledge, information, and belief.
Should you have any questions concerning this issue, please call Mr. Manuel W. Gutierrez of nty staf f, at (803) 345-4392, at your convenience.
Very truly yours, EsE
/
John L. Skolds MWG:JLS: led
[
Enclosures N
c:
See Page 2 I
9102130006 91020t l
ADOCK0500g5 DR
Document Control Desk TSP 910003-0 Page 2 of 2 c:
- 0. W. Dixon Jr. (w/o Enclosures)
R. R. Mahan R. J. White S. D. Ebneter G. F. Wunder General Managers NRC Resident Inspector J. B. Knotts Jr.
File (813.20)
NUCLEAR EXCELLENCE - A SUMMER TRADITION!