Enclosure to Sarini: RSEP/82-1988 Page 1 of 3 OPERATING DATA REPORT DOCRET NO: 50-261 DATE: R91?nt N

COMPLETED BY:

H. Rav Norris TELEPHONE:

(803) 383-4524 OPERATING STATUS Notes:

1. Unit Name:

H. B. Robinson Unit #2

2. Reporting Period: 821101, 0000 / 821130, 2400 There are presently 157 spent fuel
3. Licensed Thermal Power.(FMt): 2300 assemblies in the spent fuel pool.
4. Nameplate Rating (Gross MUc):

739

5. Design Electrical Rating (Net MWe):

700

6. }bximum Dependable Capacity (Gross FMe): 700

, 7. Maximum Dependable Capacity (Net MWe):

665

-t

8. If Changes occur in Capacity Ratings (Item Number 3 throug13 1) Since Last Report, 91ve Reasons:

No Change

9. Power Level to Which Restricted, If Any (Net MWe):

1955 MWt Reactor Power

10. Reusons For Restrictions, If Any: Although the unit is not restricted by any outsloe the power level is presently reduced due to steam generator considerations.
agency, This Month' Yr.-to-Date Cumulative
11. Hours in Reporting Period 720 8016 102942
12. Number of Hours Reactor Was Critical 688.97 3786.9 76132.32
13. Reactor Reserve Shutdown Hours 31.03 31.03 1116.33
14. Hours Generhtor On-Line 687.2 3575.84 74131.15
15. Unit Reserve Shutdown Hours O'

0 23.20 16, Gross Thermal Energy Generated (MWH) 1265349.6 6372019.6 149467393.6

17. Cross Electrical Energy *Cencrated (FMH) 404872 2C14395 48092365
18. Not Electrical Energy Generated (MWH) 380823 1860227 45480478 j
19. Unit Service Factor 95.44 44.61 72.01 l
20. Unit Availability Factor 95.44 44.61 72.03
21. Unit Capacity Factor (Using MDC N'et) 79.54 34.89 66.44
22. Unit Capacity Factor (Using DER Net) 75.56 33.15 63.11 I
23. Unit Forced Outage Rate 4.32 7.86 14.29 l
24. Shutdowns Scheduled Over Next 6 lbnths (Type, Date, and Duration of Each):

Type Two 5/14/83, Four Week Steam Generator Inspection Outagei l

December 1, 1982

75..IC Shut Down At End of Report Period, Estimated Date of Startup:
26. Units In Test Status (Prior to Connercial Operation):

Forecast Achicved i

INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION (9/77) 8212060201 821203 PDR ADOCK 05000261 R

PDR t

Enclosure to Serial: RSEP/82-1988

-' Page 3 of 3 4

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-261

11. B. Robinson UNIT DATE 821201 H. Ray Norris COMPLETED BY TELErilONE (803) 383-4524 MONT11 November DAY AVERAGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER I.EVEL (MWe NetI (MWe Net) 563 563 g7 562 564 2

33 561 562 3

39 563 552 4

20 560 500 g

21 555 560 6

560 507 73 7

560 g

561 24 561 560 9

25 560 561 10 26 560 562 11 27 562 12 28

~

562 295 33 29 14 563 30 0

564 15 3,

564 16 INSTRUCTIONS On this format. list the av::se; daily unit power levelin Mwe. Net for each day in the reporting nwnth. Compute to the neuest whole rm:2 wit.

(9/77)

~

<1

+

~

l Enclosure to Serial: RSEP/ 82--1988 Page 2 of 3 i

DOCKET NO.

50-261 UNIT S!!UTDOWNS AND POWER REDUCTIONS UNIT N AME H.

B.

Robinson DATE R?1?nt COMPLETED BY u

% %,,4c REPORT MONTil November TELEPilONE (ROM ~ 183-4524 e.

E e

.! ?

3

$.Y 5 Licensec j r, Ev),

"Cause & Corrective N"-

DJte i.

5?

.i s 5 Event 37 h'

Action to uiO 5

Prevent Recurrence

~ s :1 Report 8 H

A, E c's i

u 9

WC VALVEX S/G chemistry was unacceptable due 11-01 821129.

1 3103 A

3 to mechanical failure of caustic injection valves. This resulted in inleakage of sodium hydroxide into the make-up water system and and from there into S/G's.,

The valves were replaced.

4 3

Exhibit G-Instructions 2

Method:

3

1. lariual for Preparatum of Data F: Forced Reawn:

S: Scheduled A l'quipment Failure (Explain).

2-Manual Scram.

Entry Sheets for Licensee 3 Automatic Scram.

Event Rep.nt (LER) Fde tNUREG-Il-Maintenance of Test C-Refueling 4.Other (Explain) 0161)

D.Reputato > Restriction E-Ope:atos Training & License Examination 5

F Adnunistrative Exhibit I-Same Source G Operational Error (Explain)

' 19/77)

Il-Other (Explain) g

... ~.