ML20066H126

From kanterella
Jump to navigation Jump to search
Forwards Table 1, Summary of CPR Adjustments for Oyster Creek Cycle 13 Channel Bow at Most Limiting Time in Core Life for CPR (5.5 Gwd/Mt), in Response to NRC Request for Addl Info Re 901231 Submittal
ML20066H126
Person / Time
Site: Oyster Creek
Issue date: 02/13/1991
From: Devine J
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
5000-91-2021, C320-91-2055, NUDOCS 9102200176
Download: ML20066H126 (2)


Text

_ _ - _ _ _ - _ _

.v GPU Nuclear Corporation NUCaw5En -

hegn One Upper Pond Road Parsippany, New Jersey 07054

. 201 316-7000 TELEX 136 482 Writer's Direct Dial Number:

February 13,'1991-5000-91-2021 C320-91-2055 U. S. Nuclear Regulatory Commission Att: Document Control Desk Washington, DC 20555 Gentlemen

SUBJECT:

OYSTER CREEK NUCLEAR GENERATIN STATION (OCNGS)

DOCKET No. 50-219, LICENSE NO. DPR-16 OYSTER CREEK FUEL CHANNEL BOWING Ref9rences (1) GPU Nuclear Letter, December 31, 1990, " Cycle 13 Specific Analysis - Fuel Channel Bowing."

Reference (1) provided the Oyster Creek, cycle 13 specj2ic analysis for-fuel channel bowing to the NRC.

As part of the NRC's technical review of this submittal, a request was made for additional information.

Attached to this letter is Table.1, " Summary of the CPR Adjustments'for Oyster Creek Cycle 13 Channel Bow at the Most Limiting' Time in Core Life for CPR (5.5 GWD/HT)," which supplies the requested information.

If you have any questions on this submittal, please contact Mr. hichael Laggart, Manager, Corporate. Nuclear Licensing at-(201) 316-7968.

Sincerely, G'

f.A.be ta,e, sv.

J.

C.

Devine, Jr.

Vice President, Technical Functions JCD/RZ/ pip Attachment cci Administrator, Region 1 NRC Resident Inspector NRC Oyster Creek Project'Hanager D

9102200176 910213

. s./

PDR ADOCK 05000219 i

gg/

-l P

PDR e-p-

R2:C3202055 f /' j

, f GPU NurJear Corporahon la a subsdiary of General Public Ut:fities Corporation f

I

I 4

TABLE 1 Summary of-the CPR Adjustments for Oyster Creek Cycle 13 Channel Bow at the Most Limiting Time in Core Life for CF*t (5.5 GWD/MT)

BOW FOR CELL LIMITING AVERAGE CIR CPR FUEL

. TYPE OF CORE

" BUNDLE BOW BEFORE

% OF AFTER _

% OF TYPE CHANNEL LOCATION (MILS)

-(MILS)

ADJUS7 MENT LIMIT ADJUSTMENT LIMIT' l-1 GE338

'NEW 37-20 18 47 1.682 89.8

- 1. 62 6..

92.9 2

.GE338 NEW 33-16 18 77 1.683 89.7

.1.528 92.8 3

G3338 NEW 31-22.

18 59

1. 7:ci.

87.6

'1.667 90.6 4

GE321

-NEW 29-08 18-

.' 9 3 -

1.732

~87.1 1.677 90.0-4 5

GE321 NEW 45-24.

18 57 1.740'

.86.8.

1.685 89.6:

g 6

GF M.1 NEW.

~39-22 18-59 1.755 86.0

- 1.697 89.0' t

l 7

Gi. * ? '

tIEW 31-14 18 72 1.758.

85.9.

1.700 88.8:

.i 8'

GE33S NEW 27-06 18 43

-1.763 85.6-1.708-88.4 9

'GE339 NEW 35-22 18-48 1.775 85.0.

1.717 87.9 1

10 GE338 NEW~

31 18-66

~ 1. 7 7 8..

84.9:

1.720 87.8 11 GE338 NEW

~ 47-26 18 43

1.782 84.7 1.726 87.5 12-GE321-NEW 39-14

'.16 50 1.829 82.6.

1.7.70 85.3 i

13 GE321-NEW-41-24~

18 43:

1.839' 82.1-1.779 84.9 5

114 GP.321 NEW

'29-12a 18.

43

~1.840 82.1-

.1.780 84.8 a5' GE338 NEW.

'31-06

-18 93-1.887-

"80.0 1.826 82.7' 1

]

- a

- 1 61-GE321 NEW 27-08.

34 43

-1.892' 79.8-1.840' 82.1-e J

I l

l m..

~,.-~..__.a,,,_.._