=. -. _

ATTACilNP.NT 1 CORE OPrJtATING LIMIT 3 REPORT CYCL 2 3 i

r i

9012190099 901214 PDR ADOCK 05000440 P

PDR M

.+,-y

OM18 PDB-F0001 Paget i

Rev.:

O PLANT DATA BOOK ENTRY SUBMITTAL SHEET TITLE:

CORE OPERATING LIMITS REPORT POR THE PERRY NUCLEAR POVER PLANT, UNIT 1 CYCLE 3 (RELOAD 2)

PDB -

F0001 /Rev. O EFFECTIVE DATE:

'l D

NPLt J11 TCN:

OkA PAGES AFTECTED: Mh SCOPE OF CHANGE:

N/A

REFERENCE:

PY-CEI/NRR-1104 L PY-CEI/NRR-1157 L PY-NRR/CEI-0529 L PREPARED BY R. A. Loef fler

'"8, d. M4 12-1-90 W

Date REVIEVED BY:

OA4fk

>fdh ~

/M"/M 80 M /' " " ~

Date

'Wh A*//Ilc r bk}* kDW

/E ~}9 /[)

APPROVED BY:

' Manager - Sponsoring Group Date' TAB F USE ONLY PORC HEETING NUMBER:

90-ll!

__/2/l3/fo Date APPROVED BY:

v41,[

40k y

/)

?

7 t

( PPTD Director ~

Da'te

1 1

OH18s PDB-F0001 Page 1 Rev.: O LMIT 1 CORE OPERATING LIMITS REPORT 4

INDEI Specification Page INTRODUCTION AND REFERENCES 2

AVERAGE PLANAR LINEAR HEAT GENERATION RATE 3

(CORRESPONDS TO TS 3.2.1)

Figure 3.2.1-1 Flov Dependent KAPLHGR Factor (MAPFAC )

4 g

Figure 3.2.1-2 Power Dependent KAPLHGR Factor (MAPFAC )' 5 p

Figure 3.2.1-3 MAPLHGR Versus Average Planar Exposure, 6

Fuel Type BP85RB219 Figure 3.2.1-4 MAPLHCR Versus Average Planar Exposure, 7

Fuel Type BP85RB176 Figure 3.2.1-5 MAPLHGR Versus Average Planar Exposure, 8

Fuel Type BS301E Figure 3.2.1-6 MAPLHGR Versus Average Planar Exposure, 9

Fuel Type BS301F Figure 3.2.1-7 MAPLHGR Versus Average Planar Exposure, 10 Fuel Type GE88-P850B320-9GZ-120H-150-T Figure 3.2.1-8 MAPLEGR Versus Average Planar Exposure, 11 Fuel Type GE8B-P850B322-7GZ-120M-150-T HINIMUM CRITICAL POVER RATIO (CORRESPONDS TO TS 3.2.2) 12 Figure 3.2.2-1 Flow Dependent MCPR Factor (MCPR )

13 g

Figure 3.2.2-2 Power Dependent MCPR Factor (MCPR )

14 p

LINEAR HEAT GENERATION RATE (CORRESPONDS TO TS 3.2.3) 15 i

CICLE 3 CORE OPRRATING I

PERRY UNIT 1 LIMITS REPORT

r OH18: PDB-P0001 Page 2 Rev.: 0 INTRODUCTION AND REFERENCES I?frRODUCTION This Core Operating Limits Report for PNPP Unit 1 Cycle 3 is prepared in accordane,e with the requirements of PNPP Technical Specification 6.9.1.9.

The core operating limits presented vere developed using NRC-approved methods (Reference 2).

Results from the reload analyses for the General Electric fuel in PNPP Unit 1 for Cycle 3 are documented in References 3, 4 and 5.

The cycle-specific core operating limits for the following PNPP Unit 1 Technical Specifications are included in this report:

1.

Average Planar Linear fleat Generation Rate (APLilGR) Limits for each fuel / lattice type, including the pover and flov dependent MAPPAC curves.

(Technical Specification 3/4.2.1) 2.

Minimum Critical Pover Ratio Operating Limit including the power and flow dependent HCPR curves. (Technical Specification 3/4.2.2) 3.

Linear flent Generation Rate (LilGR) Limit for each fuel type.

(Technical Specification 3/4.2.3)

REFERFECES 1.

J.R. Itall (USNRC) to H.D. Lyster (CEI), Amendment No. 33 to Pacility Operating License No. NPP-58, September 13, 1990.

2.

" General Electric Standard Applicatior for Reactor Puel-GESTAR II,"

NEDE-240ll-P-A-9 and NEDE-24011-P-A-9-US (US Supplement).

3.

" Supplemental Reload Licensing Submittal for the Perry Nuclear Power Plant Unit 1, Reload 2, Cycle 3,"

GE Docurant 23A6492 Rev. 0 (September 1990).

4.

" Supplement 1 to the Supplemental Reload Licenring Submittal for the Perry Nuclear Power Plant Unit 1, Reload 1. Cycle 2," GE Document 23A5948AA Rev. 0 (October 1988).

5.

" Supplement 1 to the Supplemental Reload Licensing Submittal for the Perry Nuclear Power Plant Unit 1, Reload 2, Cycle 3," GE Document 23A6492AA Rev. 0 (September 1990).

6.

Perry Nuclear Pover Plant Updated Safety Analysis Report, Unit 1, Appendix 15B-Reload Safety Analysis.

CYCLE 3 CORE OPERATING l

PERitY UNIT 1 LIMITS REPORT l

(

..-. _ -. =. _

OM18: PDB-F0001 Pages 3 Rev.: 0 AVERAGE PLANAR LINEAR BEAT CENERATION RATE (TS 3.2.1)

All AVERAGE PLANAR LINEAR HEAT GENERATION RATES (APLHGRs) shall not exceed the result obtained from multiplying the applicable MAPLHGR values

  • by the smaller of either the flow dependent MAPLHGR factor

'(MAPFAC,) Figure 3.2.1-1, or the power dependent MAPLHGR factor (MAPFAC )

p Figure 3.2.1-2.

L These applicable MAPLHGR values are:

1.

Those for the respective fuel and Inttice type as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) e or, 2.

When hand calculations are required, the MAPLHGR as a' function

.of the average planar exposure for the most limiting lattice (excluding natural uranium) shown in Figures 3.2.1-3 through Figure 3.2.1-8 for the applicable type of fuel.

CYCLE 3 CORE OPERATING PERRY INIT 1 LIMITS REPORT-w

"-m--y-v-

7yw y-ye 9-y p

y,.re,w 97 yry.

r

-y..

,4

_y

_,7__

r O M 18: PDil F0001 Page : 4 iter. : O PNPP No 8767 liev. 9/90 1.1 1.0 r

r j

J J

r c

l' O.9 -

/

M J

P J

r g

j

$ 0.8 f

r a

E j

2 e

n 1

E

-l l

0.7 j

j r

l A

F J'

ar t

MAPFACg-MIN (1.0, 0.4574 + 0.006758F) :::

r 0.6 f

1.

l 0.5 0

20 40 60 80 100 120 CORE FLOW (% RATED), F FLOW DEPENDENT MAPLIIGR FACTOR (MAPPAC r )

FIGURE 3.2.11 CYCLE 3 CORE OPERATING PERRY UNIT 1 LIMITS REPORT

OM18: PDEF0001 Page : 5 Rev. : O PNPP Na 8768 Rev. 9'90 1.1 1.0

.r

.r

.r 9

o o

0.9

/

r l

r l

c.

a r r

p a

[ 0.8

/

r w

a r

s i

I l

/

.r

.r l

.r

. r 0.7 f

E I

t p-1.0 + 0.0052 (P 100)

MAPFAC p

40% $ P $ 100% ; All core flows f'

25 % $ P g 40% ; Core flow F $ 50%

J t

O.6

?

l MAPFACp= 0.6 + 0.002 (P-40) 25% $ P g 40% ; Core flow P > 50%

0.5 0

20 40 60 80 100 120 CORE TIIERMAL POWER (% RATED), P POWER DEPENDENT MAPLIIGR FAC'IOR (MAPFAC p)

FIGURE 3.2.12 CYCLE 3 CORE OPERATING PERRY UNIT 1 LIMITS REPORT

%T PNPP No 8769 Rev. 99) 13.5 WO EXPOSURE MAPLHGR Z*h m

13.0 (GWdit)

[k%7ft) g

%x x4 12.5 0.0 11.9

~

1.0 12.0 C

12.0

=

5.0 12.1 Z

10.0 12.2 WO L

15.0 12.3

'1 O

11.0

\\a 20.0 12.1 10.5 m

PERMISSIBLE 25.0 11.6 REGION OF hZ 10.0 OPERATION U

30.0 11.2

~g 20 9.5 35.0 10.6 k

40.0 9.9 9.0

-w V*

0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 m

i AVERAGE PLANAR EXPOSURE (GWd/t) n j

h2 MAXIMUM AVERAGE PLANAR LINEAR IIEAT N'ioe,

  • $,);'[ed 0

OMo GENERATION RATE (MAPLIIGR) VERSUS linear interpolation Nh$

AVERAGE PLANAR EXPOSURE, BP8x8R I'etween adjacent points. pp $

%mr sq=

FUEL TYPE BP8 SRB 219 9

c >% M m

w o.a oee x-FIGURE 3.2.1-3 e

az e

a g

8 l

W(

PNFP No 8no Rev.9W i

EzJ O T

Z *3 EXPOSURE MAPLHG i

M 13.0 (G%d/t)

(k%7ft) m M

/F

%~

12.5 0.0 12.0

[

\\

W BP85RB176 I

1.0 12.2 g

5.0 12.7 i

II#

L Z 10.0 12.9 11.0 15.0 12.9 N

20.0 12.6 10.5 Z

PERMISSIBLE 25.0 11.7 I

g>W REGION OF L

10.0

<Z OPERATION 30.0 10.8

[

Eza 20 9.5 35.0 10.2 f

h <b 40.0 9.6 g

9.0

- 532 i

XZ 0

5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 i

e AVERAGE PLANAR EXPOSURE (GWd/t)

O i

r*

MAXIMUM AVERAGE PLANAR LINEAR IIEAT Note: Intermediate MAPLHGR

(

E_ O$g GENERATION RATE (MAPLHGR) VERSUS

      • "[

f y

MO<

AVERAGE PLANAR EXPOSURE, BP8x8R between adjecent points. ?7$

@mO

<=-

l gy FUEL TYPE BP8 SRB 176

.[E i

Uh" FIGURE 3.2.1-4 "3

Ei z e

o a

8

~

i

m w s77: ac.m

^,

13.5 EXPOSURE MAPLIIGR

(

13.0 (GWd/t)

(kWlft) r W<

12.5 0.0 12.4 m

WO BS301E 1.0 12.4 Zy 12.0 T

4' 5.0 12.8 gd EU 11.5 70 N

<W

% L 8.0 13.2 ZW 11.0

/N 10.0 13.5 C

d%

10,5 I

4 2 12.5 13.5 Mm WO 10.0 20.0 12.5 O~

'y Y k

25.0 9.5 35.0 10.4 W

9.0 az 45.0 8.9

  • W 8.5 50.0 6.9 h

PEPMISSIBLE

==k 8.0 --

REGION OF

$g OPERATION V, Z 7.5

<k 7.0 0

6.5 6.0 g

g'* y t O 0

5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 0 tU n d9y AVERAGE PLANAR EXPOSURE (GWd/t) g:;y S

  1. 3 h sb MAXIMUM AVERAGE PLANAR LINEAR IIEAT Note 1.

Intemdiate MAPtitGR aQW GENERATION RATE (MAPLIIGR) VERSUS 7,I",** ",7,

"*d h7

$[

gg AVERAGE PLANAR EXPOSURE, GE8x8EB between adjacent points.

c)

2. This curve is a composite of FUEL TYPE BS301E the most limiting enriched fuel 8

lattices. For lattice specific

'~"'"*'""'""*'*"**4-FIGURE 3.2.1-5

l 1

PNPP No 8772 Rev. 9N 13.5 EXPOSURE MAPL 11GR p

(

(GWd!t)

(kW/ft) 13.0

/r 0.0 12.6

(

l g

12.5 BS301F 1.0

<W7 12.0 5.0 12.9 h 3; 5

M J

v*

11.5 7.0 13.2 f

8.0 M

< W 11.0 z !;:

\\

10.0 13.5 C

10.5 TL 12.5 13.5

  1. j Z

X\\

~d bZ 10.0 20.0 12.5 WQ k

25.0 11.8

~

h 9.5 35.0 10.4 Z

9.0 4

g 45.0 8.9 Wg 50.0 6.9 l

PERMISSIBLE 8.0 --

REGION OF h

OPERATION f

$Q 7.5

\\

5* x 7.0 2

6.5 6.0 g

0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 h70

= en a

=

o dO<

AVERAGE PLANAR EXPOSURE (GWd/t) mo Notes:

1.

Intermediate MAPLIIGR ce M t- -

tu d 'n MAXIMUM AVERAGE PLANAR LINEAR IIEAT t

g7,I *'Ei tat $o oh" GENERATION RATE (MAPLIIGR) VERSUS e

AVERAGE PLANAR EXPOSURE, GE8x8EB between adjacent points yy h'm$,7s;d;";'ng en$c$[fuct h

FUEL TYPE BS301F lattices. For lattice specific 3

"'"*'*""""*'*""**#~

FIGURE 3.2.1-6

FNFP No 8880 13.5 EXPOSURE MAPLHGR 33,o WM WM g-(

GE8B-P85QB320-9GZ-120M-150-T o,o i3,75 f

0.2 11.78

~

Z*

12.0 -

1.0 11.83 3

4 2.0 11.91 3

M 11.5 J

%~

3.0 12.02 x

f 11.0 4.0 12.17 3

C

\\

5.0 12.32 7

A 10.5 q

Ag 6.0 IN NO 10.0 7.0 12.56 0

9.5 8.0 IUO 9.0 12.84

>W 9.0 X

10.0 12.97 i

sZ 3

W 8.5 12.5 13.00

  • C O PERMISSIBLE 15.0 12.73 D

2 <8 8.0 --

REGION OF M

20.0 trio orERArtox h

7.5 25.0 11.48 I

M 35.0 10.23 45.0 8.66 6.5 50.0 6.16

)

O 6.0 t* O I

EW 0

5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0

= to o

& y *

gh ca GENERATION RATE (MAPLIIGR) VERSUS ("";"jeh,M{ MAXIMUM AVERAGE PLANAR LINEAR IIEAT Notes: 1. Intermediate M,APL11GR H$ AVERAGE PLANAR EXPOSURE, GE8x8EB between adjacent points. o t3

2. This curve is a composite ef F

FUEL TYPE GE8B-P8SQB320-9GZ-120M-150.T the most limiting enriched fact g lattices. For Isttice specific g

    • '"*'*"'""*'*'*"ce5.

FIGURE 3.2.1-7 FNPP No 8879 Rev. 9,90 13.5 EXPOSURE MAPLHGR (GWd!t) (k%7ft) 'e 13.0 ,[ ( GE8B-P8SQB322-7GZ-12JM-150-T O.0 12.11 12.5 0.2 12.10 I h 12.0 1.0 12.09 5 h 2 2.0 12.16 gg3 s gd 3.0 12.28 < EG 11.0 4.0 12.42 I 10.5 Q d 6.0 12.67 W 2: k I- ~ 7.0 12.75 \\, WO 8.0 12.83 ,,. P 9.5 y 9.0 12.92 W 9.0 gg p 10.0 13.02 l 8.5 12.5 13.07 2O PERMISSIBLE 15.0 12.79 I 8.0 -- REGION OF 20.0 12.19 Qp 2 <G OPERATION L 7.5 25.0 11.56 i hN 35.0 10.29 45.0 8.77 6.5 50.0 6.27 3 O 6.0 3Q 0 50 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 o -NO< -o

n tG t-AVERAGE PLANAR EXPOSURE (GWd/t) 5%M

?? 9 oN" MAXIMUM AVERAGE PLANAR LINEAR IIEAT Notes: 1. Intermediate MAPLIIGR $%0 yE GENERATION RATE (MAPLIIGR) VERSUS ",I7 ;*'*,,*hI" O AVERAGE PLANAR EXPOSURE, GE8x8EB hetween adjacent points. CC@ 2. s cu a FUEL TYPE GE8B-P8SQB322-7GZ-120M-150-T i g nrYct ed fact h m9, i lattices. For lattice specific g "'"*'*""'""*'*"ce5. FIGURE 3.2.1-8 _. ~.. OH18: PDB-F0001 Page: 12 i Rev.: 0 MININUM CRITICAL POVER RATIO (TS 3.2.2) The MINIMUM CRITICAL POVER.,ATIO (HCi'R) shall be equal to or greater than both the MCPR limits at the indicated core flow. THERHAL POVER,deltah*andMCPRand core average exposure compared to the End Exposu.re (EOCE)** as specified in Figures 3.2.2-1 and 3.2.2-2. Thisdelta.Treferstotheplannedreductionofratedfeegvater temperature frm nominal rated feedvater temperature (420 F), such as prolonged removal of feedvater heatcr(s) from service. End of Cycle Exposure (E0CE) is defined as 1)'the' core average exposures at which there is no longer sufficient reactivity to achieve RATED THERMAL POVER vith rated core flov, all control rods withdravn', all feedvater heaters in service and-equilibrium Xenon, or 2) as'specified by the fuel vendor. CTCLE 3 CORE OPERATING PERRY UNIT 1 LIMITS REPORT V OM18: PDB F0001 Page : 13 PNPP Na 8773 Rev.12/90 Rev. : 0 I'O - Illi Illi 11I111 111lll1till i. 11111 il it iIII IIi1 IIi11I IIIIIIIIIII I IIIII II II I MCPH g= (1.8134 0.006948F) * [1.0 + 0.0032 (40 F)] : for i F $40% i I ,?.L__ 1.7 ---- i i JF T m a r 1, J' ~ L, j PEftMISSIBLE u s REGION OF OPERATION 1.6 i L a 1. L I t MCPR g-MAX (1.18,1.8134 0.006948F) : for 1.5 =- t p )4og s w 1. I r M 1 4 'L J n r g E t j 't i 1.4 L a w r i. L J 't r 1. 1 1 'k L 1.3 ~ t RATED OPERATING LIMIT MCPR - 1.18 t l t V l! l im NI ~ \\, Il 1.2 - ( l' 1. El ll 'I 'l 1.15 0 20 40 60 80 100 120 CORE FLOW (% RATED), F FLOW DEPENDENT MCPR FAC'IDR (MCPR ) g FIGURE 3.2.21 CYCLE 3 CORE OPERATING PERRY - UNIT 1 LIMITS REPORT O M 18: PDil F0001 Page : 14 PNPP No 8774 Rev. 9/90 Rev. : 0 2.3 TilERMAL POWER 25% < P < 40% 2.2 CORE FLOW > 50% ( [ 2.1 L - TilERMAL POWER 25% < P < 40% 2.0 - ~ ~ CORE FLOW < 50% ~ ww ' t i h l 1.9 \\ PERMISSIBLE REGION OF i l l-OPERATION 1.8 - l 1.7 TilERMAL POWER 40% < P < 70% ~~ Cr: a 4 1.6 .r O E ,m_ I u : l 1.5 S u m i TIIERMAL POWER P > 70% : 1.4 f r 2 BEFORE AND AT END OF CYCLE: yg r 1.3 -- ^II core average exposures and w. O f A T f 1000F and \\ i Core Flow f 105% s 1.2 - : AFTER END OF CYCLE: s Core average exposure > EOCE g_ and Of 6 T f1700F and Core flow $ 105% 1.0 0 20 40 60 80 100 120 CORE THERMAL POWER (% RATED), P POWER DEPENDENT MCPR FACTOR l l (MCPRp) FIGURE 3.2.2 2 CYCLE 3 CORE OPERATING PERRY UNIT 1 LIMITS REPORT h, - . ] 3. t i i OM18: PDB-F0001 Page: 15 - LAST Rev.: O LINEAR HEAT GENERATION RATE (TS 3.2.3) The LINEAR HEAT GENERATION RATE (LHGR) shall not exceed: a. 13.4 kv/ft for the following fuel types: 1. BP8 SRB 219 2. BP85RB176-- b. -- 14.4 kv/ft for the following fuel types: 1. BS301E 2. BS301F 3.- GE85-P8S0B320 9GZ-120M-150-T 4. GE8B-P850B322-7GZ-120M-150-T -i b ,i L 4 4 I CYCLE 3 CORE OPERATING

PERRY UNIT 1 LIMITS REPORT

. - ~. . _}}