Docket No. 50-423 B14635 Millstone Nuclear Power Station, Unit No. 3 Proposed Revision to Technical Specifications Area Temperature Monitoring Surveillance Requireme*ts Markup Pages April 1994 9404220240 940418 PDR ADOCK 05000423 P
PDR.
a
h,a 25, 1000-PLANT SYSTEMS 3/4.7.14 AREA TEMPERATURE MONITORING LIMITING CONDITION FOR OPERATION 3.7.14 The temperature limit of each area shown in Table 3.7-6 shall r,ot be exceeded.
APPLICABILITY: Whenever the equipment in an affected area is required to be OPERABLE.
ACTION:
With one or more areas exceeding the temperature limit (s) shown in Table 3.7-6:
a.
By less than 200F and
',r less than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, record the cumulative time and the amount by which the temperature in the affected area (s) exceededthelimit(s).
b.
By less than 200F and for more than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, prepare and submit to the Commission within 30 days, pursuant to Specification 6.9.2, a
Special Report that provi$s a record of the cumulative time and the amount by which the tungerature in the affected area (s) exceeded the limit (s) 'and an analysis to demonstrate the continued OPERABILITY of the affected equipment.
The provisions of Specification 3.0.3 are not applicable.
c.
With one or more areas exceeding the temperature limit (s) shown in Table 3.7-6 by more than 200F, prepare and submit a Special Report as required by ACTION b. above and within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> either restore area (s) to within the temperature limit (s) or declare the equip-w in the affected area (s) inoperable.
SURVEILLANCE RE0VIREMENTS 4.7.14 The temperature in each of the areas shown in Table 3.7-6 shall be determined to be within its limitt et-kat ericc Fr R h=:.
Q. M \\ead ovyx pic men da3s Whe.n b Q\\Mm is operabk)
SQ
- b. O hask (mce pu FL hufs dren Ot Go% is WW6SE -
HILLSTONE - UNIT 3 3/4 7-44 AMENDMENT NO. 57
\\
Docket No. 50-423 B14635-Millstone Nuclear Power Station, Unit No. 3 Proposed Revision to Technical Specifications Area Temperature Monitoring Surveillance Requirements Retyped Pages 1
April 1994
PLANT'S'YSTEMS 3/4.7.14 AREA TEMPERATURE MONITORING LIMITING CONDITION FOR OPERATION 3.7.14 The temperature limit of each area shown in Table 3.7-6 shall not be exceeded.
APPLICABILITY:
Whenever the equipment in an affected area is required to be OPERABLE.
ACTION:
With one or more areas exceeding the temperature limit (s) shown in Table 3.7-6:
a.
By less than 20*F and for less than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, record the cumulative time and the amount by which the temperature in the affected area (s) exceeded the limit (s).
b.
By less than 20'F and for more than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, prepare and submit to the Commission within 30 days, pursuant to Specification 6.9.2, a Special Report that provides a record of the cumulative time and the amount by which the temperature in the affected area (s) exceeded the limit (s) and an analysis to demonstrate the continued OPERABILITY of the affected equipment.
The provisions of Specification 3.0.3 are not applicable, c.
With one or more areas exceeding the temperature limit (s) shown in Table 3.7-6 by more than 20*F, prepare and submit a Special Report as required by ACTION b. above and within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> either restore the area (s) to within the teeperature limit (s) or declare the equip-ment in the affected area (s) inoperable.
KilDVFfi l ANr_F DFollf RFMFMTC 4.7.14 The temperature in each of the areas shown in Table 3.7-6 shall be determined to be within its limits-f a.
At least once per seven days when the alarm is OPERABLE, and; b.
At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> when the alarm is inoperable, j
l l
MILLSTONE - UNIT 3 3/4 7-44 Amendment No. J7, 0171