ML20065K221

From kanterella
Jump to navigation Jump to search
Amend 35 to License NPF-73,revising Tech Specs Re Letdown Line Containment Isolation Valve Stroke Time
ML20065K221
Person / Time
Site: Beaver Valley
Issue date: 11/13/1990
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Cleveland Electric Illuminating Co, Duquesne Light Co, Ohio Edison Co, Toledo Edison Co
Shared Package
ML20065K223 List:
References
NPF-73-A-035 NUDOCS 9011160139
Download: ML20065K221 (4)


Text

- - - - _ _ _ _ _ - _ -. _ - - _ - - - _ _ _ _ _

. jf#Nd UNITED STATES i

t4 NUCLE AR REGULATORY COMMISSION h

J 0, f

W ASHING T ON, D. C. 20505 To %.

l'

z, 4.%
  • l I

DUQUESNE LIGHT COMPANY i

OHIO EDISON COMPANY-

}

THE CLEVELAND ELECTRIC ILLUMINATING COMPANY THE TOLEDO EDISON COMPANY x

DOCKET NO. 50-412 I

.w BEAVER VALLEY POWER STATION UNIT NO. 2 fA AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 35 License No. NPF-73 1.

The Nuclear Regulatory Comission (the Commission) has found that:

i-A.

The application for amendment by Duquesne Light = Company,

= et al. (the' licensee) dated June 21,.1990 complies with the standards and requirements of the Atomic Energy Act of'1954,-as amended (the Act) and the Commission's rules and_ regulations set forth in 10 CFR Chapter I; q

B.

The facility will operate in cor.formity with the applica-tion, the provisions of the Act, and the rules and regu-

, lations of the Commission;

'C.

Thereisreasonableassurance(1).thattheactivities I

authorized by this ame6.dment'can be: conducted without endangering the health and safety of the public, and 1

'(ii) that such activities will be conducted in compliance with the_ Commission's regulations; j;

D.-

The11ssuance of this amendment will not be inimical to the consnon defense and security or to the health and safety of the public;.and j

t

~iE.

The issuance of this amendment-is in accordance with 10 CFR i

Part 51 of.the Commission's regulations ~and all applicable i

requirements have been satisfied.

9011160' J 901113 DR A' JOCK 05000412 PDC 3

l

2 2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-73 is hereby

' amended to read as follows:

(2)_ Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 35, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto are hereby incorporated in the license.

DLCO shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance, to be

. implemented within 60 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION f

John. Sto irector Prp' ject Directorate I (vision of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications-c

-Date of Issuance: November 13. 1990 i

i ATTACHMENT TO LICENSE AMENDMENT NO. 35 FACILITY OPERATING LICENSE NO. NPF-73 e,

DOCKET NO. 50-412 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages as indicated. The revised pages are identified by amendment

.l number and contain vertical lines indicating the areas of change.

Remove Insert 3/4 6-18 3/4 6-18 O, l,.

k

'j s

i b

i E

ma

TABLE 3.6-1 (Cont)

CONTAINMENT PENETRATIONS 55 MAXIMUM MAXIMUM E

PENT.

INSIDE STROKE OUTSIDE STROKE CE NO.- AREA IDENTIFICATION / DESCRIPTION' VALVE TIME (SEC)

VALVE TIME (SEC) c:

17 High tkad (3)(2) 25I5-84 N/A' (3)(2) 2 SIS-MOV8698-N/A

'{

Safety Injection (13) 19

-Seal-Water from (A)

-2CHS-MOV378

< 60 (A) 2CHS-MOV381

< 60 Reactor Coolant Pump 2CHS-473 N/A 20 Safety Injection 2 SIS-42 N/A (1) 2 SIS-41 N/A Accumulator Makeup 2 SIS-RV130 N/A 21 Chill & Service Wtr-(B) 25WS-MOV155-2 < 60 (B) 25WS-MOV155-1

< 60 from Cont.-Air 25WS-RV155 N/A Recirc Cooling Coils us

,n 22 SPARE 7

v 23 SPARE 24 Residual Heat Removal 2RHS-107 N/A 2RHS-15 N/A to Refueling Water Tank 2RHS-RV100 N/A 25 Chill & Service.Wtr (B) 25WS-MOV154-2 < 60 (B) 25WS-MOV154-1

< 60 from Cont. Air Recirc 25WS-RV154 N/A Cooling Coils 27 Chill & Service Wtr (B) 25WS-MOV152-2 < 60 (B) 25WS-MOV152-1

< 60 E

to Cont. Air Recirc 25WS-RV152 N/A j

Cooling Coils e

me 28 Reactor Coolant Letdown (A) 2CHS-A0V200A

< 60 (A) 2CHS-A0V204

< 60 (A) 2CHS-A0V200B

< 60 (A) 2CHS-A0V200C

< 60 us (1) 2CHS-HCV142 N/A 2CHS-RV203 N/A

'