_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ums E3 8

Du TABLE 3.6-1 (Cont.)

CONTAINMENT ISOLATION VALVES f

Of PENETRATION ISOLATION b

NUMBER VALVE NUMBER FUNCTION TIME (SEC) m

,88 g $4 C. MANUAL (Cont.)

G LD e 1

2C3 2CV-5432#

Fuel Transfer Tube Isolation (outside)

N.A.

y D. OTHER (Check Valves) 2P9 2N -18 H.P. Nitrogen to SI Tanks (inside)

N.A.

2 2P39 2CVC-78 Quench Tank Makeup & Demin Water Supply (inside)

N.A.

2P40 2FS-37 Fire Water Isolation (inside)

N.A.

2P41 2N -1 L.P. Nitrogen Supply Isolation (inside)

N.A.

2 2P43 2SA-69 Service Air Supply Isolation (inside)

N.A.

w 2P46 2BA-216 Breathing Air Supply Isolation (inside)

N.A.

1 2P51 2AC-49 Chilled Water Supply Isolation (inside)

N.A.

-9 2P52 2CCW-38 CCW to RCP Coolers Isolation (inside)

N.A.

  1. Not subject to Type C leakage tests.
  • May be opened on an intermittent basis under administrative control.