Text

_ _ _ _ _ _ _ _ _ _

Washington Public Power Supply System Box 1223 Elma, Washington 98541 (206)482-4428 Docket No. 50-508 February 16, 1983 G03-83-145 Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

POTENTIAL 10CFR50.55(e) DEFICIENCY DIFFUSER RETAINING CAP SCREWS -

REACTOR COOLANT PUMPS (D/N #46)

Attached is a copy of the final report provided to Region V concern-ing a potential 10CFR50.55(e) deficiency associated with the subject condition.

Should you have any questions or desire further information, please contact me directly.

I s

(

. S. Leddick (760)

Program Director, WNP-3 DRC:nj i

Attachment cc:

J. Adams - NESCO, wo/a D. Smithpeter - BPA, wo/a Ebasco - New York, wo/a WNP-3 Files - Richland, wo/a TEA 7 F302230148 830216 PDR ADOCK 05000508 s

PDR

_ _ _ _ _ _ _ _