Text
..
Omaha Public Power District 1623 HAMNEY E OMAHA. NE8RASMA 68102 e TELEPHONE S36-4000 AREA CODE 402 December 30, 1982 LIC-82-414 Mr. Robert A. Clark, Chief U. S. Nuclear Regulatory Comission Office of Nuclear Reactor Regulation Division of Licensing Operating Reactors Branch No. 3 Washington, D.C.
20555
References:
(1) Docket No. 50-285 (2) Letter from R. W. Wells, CE Cwners Group Chaiman, to D. G. Eisenhut, NRC, " Transmittal of CEN-152, Revision 1, Combustion Engineering Emergency Pro-cedure Guidelines," hovember 22, 1982
Dear Mr. Clark:
NUREG-0737, Item I.C.1 Revised Emergency Procedures Reference (2) transmitted the Combustion Engineering Owners Group's (CE0G's) latest report and revision to the emercency procedure guide-lines.
These guidelines were developed in response to the requirements of the subject TMI Action Plan item.
The purpose of this letter is to reference CEN-152, Revision 1, as being applicable to the Fort Calhoun Station in fulfilling part of the requirements of Item I.C.1.
As stated in the District's letter dated June 4,1982, integration of these emergency procedure guidelines into the Fort Calhoun Station procedures will be completed by the end of the first refueling outage comencing six months after Commission approval of the guidelines.
Sincerely,
(
/ij((gd W. C. Jones Division Manager Production Operations WCJ/TLP:jmm cc: LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N.W.
Washington, D.C.
20036 8301110440 821230 PDR ADOCK 05000285 P
pop
,