ML20064C646

From kanterella
Jump to navigation Jump to search
Submits Info Re Possible Deficiency in Calculation of LOCA Peaking Factor Shape Limits by the Axial Power Distribution Monitoring Sys
ML20064C646
Person / Time
Site: North Anna 
Issue date: 10/11/1978
From: Brown S
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 7810230264
Download: ML20064C646 (2)


Text

.

VIRGIN $ A ELECTRIC AND POWER COMP ANY, RICHMOND, VIRGINI A 23268 1

October 11, 1978 Mr. James P. O'Reilly, Director Serial No. 575 Office of Inspection L Enforcement PSE&C/LCK/bep/mc U. S. Nuclear Regulatory Commission

.T Region II Docket No. 50-339 101 Marietta Street, Suite 3100 Atlanta. Georgia 30303

Dear Sir:

On October 6,1978, a report was made under the p ovisions of 10CFR50.55(e)

%g-*n%c a,p_ossible deficiency in the calculation of the LOCA peaking factor

'snfMts 15f^t'he -APDMS hardware for North Anna Unit 2.

~

In accordance with the reporting requirements of 10CFR21, the following information is submitted:

A.

Name and address of reporting individual:

Mr. E. A. Baum. Executive Manager Licensing and Quality Assurance Virginia Electric and Power Company P. O. Box 26666 Richmond, Virginia.

23261 B.

Facility, activity, and/or component affected:

a __

North Anna Power Station, Unit 2

-T Z.

AxiaT-Power Distribution Monitoring System (APDMS)

C.

Name of firm constructing the facility or supplying the component,

~

activity or service.

Westinghouse Electric Corporation Water Reactor Divisions P. O. Box 355 Pittsburg, Pennsylvania 15230

~

D.

Description of defect, deficiency, or failure to comoly:

A similar facility utilizing Westingbouse APDMS hardware for cal-culating the LOCA peaking factor shape limits, discovered a non-conservative error in the computer software which determined the alarm setpoint envelope. This error is caused by a calculational round off which could increase the setpoint above the desired value by as much as 1.1%.

77/0NOMY b

\\

m. -

vmomiA ELECTRIC Ano Powen COMPANY TO Mr. James P. O'Reilly SMaar No.

2 E.

Date of determination of reportability:

October 6, 1978 F.

Similar components, activities, or services:

North Anna Power Station, Unit 1 G.

Corrective action which has been, is being or will be taken, the indi- -

vidual responsible and the length of time to complete the action:

The equipment is not yet operational. A pennanent solution is currently being discussed with Westinghouse.

H.

Other information:

None Any information not available at this time will be submitted in a follow-up letter as a 30-day report.

Should you require further information, please contact this office.

er,

uly curs f[Qi i

Sa C. Brow,

Vi e President - Power ta ion E gineering and Constr t'on cc: Director, Office of Inspection andEnforcement(3) e

'~

p

-,y y.%

e,,

,,~,-a-v

. w e.,

c p

,--s 7,-

-,,-,----c,- - -

_