ML20064C116

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs Modifying Containment Isolation Valve Table Allowing Entry Into Higher Mode Under Action Statement
ML20064C116
Person / Time
Site: Summer 
Issue date: 12/28/1982
From:
SOUTH CAROLINA ELECTRIC & GAS CO.
To:
Shared Package
ML20064C114 List:
References
NUDOCS 8301040322
Download: ML20064C116 (2)


Text

. - _ _ _ -

T@@

TABLE 3.6-1 (Continued) 20 m po E CONTAINMENT ISOLATION VALVES 88 4 ou "

MAXIMUM

  1. 38 '

VALVE NUMBER ISOLATION TIME E

A.

PHASL 'i " ISOLATION (Continued)

FUNCTION (SEC)

A a3 8PJ

~

g;g

  • 31.

9312A-SS Sampling Line Supply Return From Radiation Monitor 40 nua pa "

32.

93128-55 Sampling Line Return Return From Radiation Monitor 40

@jCD 33.

9339-55 Sample Return Line To PRT 40 34.

9341-5S Sample Return Line To PRT 40 35.

9356A-SS Sampling Line From Pressurizer 40 36.

93568-55 Sampling Line From Pressurizer 40 37.

9357-55 Sampling Line From Pressurizer 40 38.

93648-5S Sampling Lines From Reactor Coolant loop B 40 39.

9365B-55 Sampling Lines From Reactor Coolant Loop B 40 40.

9364C-SS Sampling Lines From Reactor Coolant Loop C 40 41.

9365C-SS Sampling Lines From Reactor Coolant Loop C 40

)

42.

9387-55 Sampling Line From Accumulators 40 t!

43.

9398A-SS # (2)

Sampling Line From Steam Generator A Blowdown 40 I

44.

93988-55 # (3)

Sampling Line From Steam Generator B Blowdown 40 T

45.

9398C-SS # (3)

Sampling Line From Steam Generator C Blowdown 40 E!

46.

7126-WL Reactor Coolant Drain Tank Vent Header 40 47.

7150-WL Reactor Coolant Drain Tank Vent Header 40 48.

1003-WL Reactor Coolant Drain Tank Discharge To Waste 40 j

49. '7136-WL Reactor Coolant Drain Tank Discharge To Waste 40 a

B.

PHASE "B" ISOLATION

(

1.

9568-CC Component Cooling To R. C. Pumps Bearings 60 2.

9600-CC Component Cooling To R. C. Pumps 60 3.

9605-C Component Cooling From R. C. Pumps Bearings 60 4.

9606-CC Component Cooling From R. C. Pumps Bearings 60 5.

1633A-FW #

Chemical Feed Line To Feedwater Loop A 60 i

6.

1633B-FW #

Chemical Feed Line To Feedwauer Loop B 60 7.

1633C-FW #

Chemical Feed Line To Feedwater Loop C 60 C.

REACTOR BUILDING PURGE SUPPLY AND EXHAUST ISOLATION 1.

0001A-AH Reactor Building Purge Supply 5

2.

00018-AH Reactor Building Purge Supply 5

3.

0002A-AH Reactor Building Purge Exhaust 5

-)

p D

r r

(3 3

^

TABLE 3.6-1 (Continued)

C CONTAINMENT ISOLATION VALVES MAXIMUM i

c VALVE NUMBER ISOLATION TIME F.

CHECK FUNCTION (SEC) 1.

7541-AC CRDM Coolant Water Inlet Line N/A 2.

7544-AC CRDM Coolant Water Outlet Line N/A 3.

9570-CC Component Cooling To R. C. Pump Bearings N/A 4.

9689-CC Component Cooling From R. C. Pump Bearings N/A 5.

8103-CS Reactor Coolant Pump Seal Water Return N/A 6.

8368A-CS Seal Injection To R. C. Pump A N/A 7.

8368B-CS Seal Injection To R. C. Pump B N/A 8.

8368C-CS Seal Injection To R. C. Pump C N/A 9.

8381-CS Charging Line To Regenerative Heat Exchanger N/A 10.

6799-FS Fire Service Deluge To Charcoal Filters N/A 11.

2661-IA Instrument Air Supply To Reactor Building N/A w

12.

6588-NG Nitrogen Supply To Steam Generators N/A 1

13.

8046-RC Pressurizer Relief Tank Makeup Water Line N/A cn 14.

2913-SA Service Air Supply To Reactor Building N/A E

15.

3009A-SP Supply To Reactor Building Spray Nozzles N/A R

16.

30098-SP Supply To Reactor Building Spray Nozzles N/A 17.

8947-51 Accumlator Nitrogen Supply N/A 18.

8861-SI Fill Line To Accumulators N/A

(

  1. Valve not subject to Type "C" leakage test.

(1) Manual valves may be opened on an intermittent basis under administrative control.

(2) Remote manual valve positions are maintained by administrative control.

(3) The pu,slws of gg, g,

,.,, 3, a y,,.,

7 j;g g g wrz 47gy Je ly s, s 9g 3,

--.. _. _..