Dockst nos. 50-528/529/530 50.55(o) Report

.- m -e q_

s N

N NJED INbNb 3003 STA.

,,o,oox 23... pgogn,x,gnizon,.3o3, Septemberil5,~1982 ANPP-21836-GHD/BSK U. S. Nuclear Regulatory Commission Region V Creekside Oaks Office Park 1450 Maria 1.ane - Suite 210 Walnut Creek, California 94596-5368 Attention:

Mr. D. M. Sternberg, Chief Reactor Projects Branch 1

Subject:

Interim Report - DER 82-45 A 50.55(e) Potentially Reportable Deficiency Relating to C. E./Borg-Warner Safety Injection System Valves Installed With Motor Operator 9 Not Qualified For Inside Containment.

File:

82-019-026 D.4.33.2

Reference:

Telephone Conversation between J. Eckhardt and G. Duckworth on August 26, 1982

Dear Sir:

The NRC was notified of a potentially repos uble deficiency in the referenced telephone conversation. At that time, it was estimated that a determination of reportablilty would be made within thirty (30) days.

Due to the extensive investigation and evaluation required, an Interim Report is attached.

It is now expected that this information will be finalized by November 17, 1982, at which time a complete report will be submitted.

Very truly yours, T

CCLL qQ E. E. Van Brunt, Jr.

APS Vice President Nuclear Projects Management ANPP Project Director EEVBJr/GHD:db Attaclanent ec: See Attached Page 2 D W10070339 820915 I=PER ADOCK 05000528 l

-;s_

_ pm.

i.

I

, ~.

U. S. Nuclear Regulatory Commission September 15, 1982 Attention:

Mr. D. M. Sternberg, Chief ANPP-21836-GHD/BSK Page 2 cc: Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 T. G. Woods, Jr.

J. A. Roedel D. B. Fasnacht G. C. Andognini A. C. Rogers B. S. Kaplan W. E. Ide J. Vorees J. A. Brand A. C. Gehr

~

W. J. Stubblefield l

W. G. Bingham i

R. L. Patterson l

R. W. Welcher R. M. Grant D. R. Hawkinson L. E. Vorderbrueggen G. A. Fiorelli Lynne Bernabei, Esq.

Harmon & Weiss 1725 "I" Street, NW Suite 506 Washington, D. C. 20006 R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503 l

___________)

5 INTERIM REPORT - DER 82-45

. POTENTIAL REPORTABLE DEFICIENCY ARIZONA PUBLIC SERVICE COMPANY (APS)

PVNGS UNITS 1, 2 & 3 i

I.

POTENTIAL PROBLEM A review of_ Combustion Engineering (CE) letter V-CE-6506 dated l

May 28, 1982, indicated motor operators for CE Tag Number SIC-UV-653 and SID-UV-654 were supplied with "outside-cortainment" motor operators instead cf qualified ".inside-containment operators".

l This error is attributed to the valve manufacturer Borg-Warner Corporation. This condition was not detected by CE prior to turning Unit 1 Sybsystem 1-SI-07 over to APS for preoperational testing.

II.

APPROACH TO AND STATUS OF PROPOSED RESOLUTION Bechtel is currently corresponding with CE to disposition this iten.

The subject motor operators are being returned to Borg-Warner for modification.

j III. PROJECTED COMPLETION OF CORRECTIVE ACTION AND SUBMIITAL OF THE FINAL REFORT l

Evaluation of this condition and submittal of the Final Report is forecast to be completed by November 17, 1982.

i:

.