Text

r 3

/

o FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNITS 3 AND 4 EMERGENCY PROCEDURE 20101 JUNE 10, 1982

1.0 Title

DUTIES OF EMERGENCY COORDINATOR 2.0 Approval and List of Effective Pages:

2.1 Approval :

Change dated 6/10/82 Reviewed by PNSC June 10, 1982 Approved by

/41 ant Mgr-Nuclear, M /d 19 / 2 l!/u[jd Approved by Vice President of 8

7D 19 L/

/ Nuclear Energy 2.2 List of Effective Pages:

Page Date Page Date Page Date Page Date 1

6/10/82 8

3/8/82 15 3/8/82 22 3/8/82 2

3/0/82 9

6/10/82 16 3/8/82 23 3/8/82 3

3/8/82 10 3/8/82 17 3/8/82 24 3/12/82 4

6/10/82 11 3/8/82 18 3/8/82 25 3/8/82 5

6/10/82 12 6/10/82 19 3/8/82 26 3/8/82 6

3/8/82 13 3/8/82 20 3/8/82 27 3/8/82 7

6/10/82 14 3/8/82 21 3/8/82 28 3/8/82 29 3/8/82

3.0 Scope

3.1 Purpose

This procedure provides the guidelines to be followed by the Emergency J

Coordinator when an emergency occurs that requires initiation of the Q.

Emergency Plans.

3.2 Discussion

The Nuclear Plant Supervisor becomes the Emergency Coordinator upon initiation of the Emergency Plans and, as such, directs 'the On-Site Emergency Organization to bring the emergency under control.

A member of the plant management staff may assune the role of Emergency Coordinator when he reaches the Control Room and becomes familiar with the emergency.

The i

Nuclear Plant Supervisor will then concentrate on control of the reactor.

g=

3.3 Authority

Turkey Point Plant Radiological Emergency Plan 8209210521 820830 PDR ADOCK 05000250 F

P_DR l g'

. _.,, _.-_1

. m. m m.._m.m n,, 7. s.

m..,.m

_y.,.

r 1

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 2 DUTIES OF EMERGENCY COORDINATOR f

4.0 Precautions

4.1 The Nuclear Plant Supervisor and the shift operating staff represent the first-line of response to any developing emergency condition.

The primary responsibility of the Nuclear Plant Supervisor is to' control the condition as well as possible.

However, the success of the Emergency Plan and procedures requires lorompt classification of the emergency (in accordance with Emergency Procedure 20103) and notificationsl of designated off-site authorities and the FPL Off-Site Emergency Organization.

4.2 The Emergency Coordinator :nay delegate his responsibilities at his f'

discretion with the exception of the decision to notify state and local

A authorities and the reconsnendation,0f protective actions for the public (off-site).

4.3 lDuring all exercises, drills or tests ALL messages si begin and end with "This is a Drill" or "This is an Exercise".

4.4 Protective action recommendations to State and Local au norities cannot be delegated by the Emergency Coordinator.

However, these reconsnendations become the res operationali. ponsibility of the Recovery Manager when the EOF is manned and

5.0 Responsibilities

N' 5.1 If the Nuclear Plant Supervisor is incapacitated, the Emergency Coordinator shall be (in order of succession):

5.1.1 Nuclear Watch Engineer 5.1.2 Any other member of the plant staff with a Senior Reactor Operator license.

5.1.3 One of Nuclear Control Center Operators on shift.

5.2 The Emergency Coordinator shall only grant permission for watch relief, including his own, when the emergency condition is sufficiently under control to make it safe in his judgment to do so.

5.3 A member of the plant management staff may, assume the -duties of the

~

Emergency Coordinator.

6.0 References 6.1 Turkey Point Plant Radiological Emergency Plan 6.2 Emergency Procedure 20'93, Classification of Emergencies and Criteria for Evacuation 6.3 Emergency Procedure 20126, Los: of Coolant Accident Dose Calculations

_ h) 7.0 Records and Notifications:

7.1 All significant information, events, and actions taken during the emergency period shall be recorded in the Nuclear Plant Supervisor's Log Book.

t

)

3.- -

_3 m y

4 y&

pg c

.w

=

e t

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 3 DUTIES OF EMERCENCY C0ORDINATOR 8.0 Instructions :

8.1 Upon becoming aware of an off-nomal condition, the Nuclear Plant Supervisor shall diagnose the condition and direct initial corrective action to control or mitigate the condition.

8.2 Then the Nuclear Plant Supervisor shall, using the tables in Emergency Procedure 20103, Classification of Energencies, classify the condition and thereby detennine if the condition constitutes an unusual event, alert, site area emergency, or general emergency.

If the condition is an unusual event, alert, site area emergency, or general emergency, the Nuclear Plant Supervisor shall declare an emergency and become the Emergency Coordinator.

The State Warning point at the Bureau of Disaster Preparedness (BOP) shall be notified within fifteen minutes of the emergency declaration.

8.3 Then the Emergency Coordinator shall station himself in the Control Room and shall begin following the steps in the applicable attached checklist (s)

(unusual event, alert, ~ site area emergency, general emergency, fire or explosion, medical emergency).

8.4 The Emergency Coordinator may designate one or more persons to handle the offsite ccmmunications and notifications required in the checklists.

The Emergency Coordinator shall designate a person to stay on the ENS circuit with the NRC until the NRC gives permission to hang up.

The designated individuals may be from the operating shift, from plant staff, or from other available personnel.

a 8.5 The initial notification to BDP shall be made within fifteen minutes of the declaration of the energency and shall be made by lNAWAS.

The initial notification shall include items of the Emergency Information Checklistl.

8.6 Each of the checklists for an emergency (unusual event, alert, site area emergency, and general emergency) require notifying the Duty call Supervisor. This should be accomplished as follows:

l The duty call supervisor for any given week will be indicated in a letter signed by the Plant Manager and available in the Control Room.

Each duty call supervisor's telephone number will be listed in the letter.

l

{C If Duty Call Supervisor is not avail 6ble at listed phone, place beeper call by dialing on any PTP Bell phone switchboard extension as follows:

l 8-102-119-892.

When the beeper ntsnber is reached, there will be a series of high pitched tones in the telephone receiver that alerts the beeper carrier that a message is to be transmitted.

When the high pitched tones cease, j

speak slowly and clearly into the telephone and tell the Duty Call Supervisor (by name) to call the Turkey Point Plant.

Repeat message, then hang up the telephone.

EXAMPLE:

%e:

'nith, call Turkey Point Plant - Joe Smith, call Turkey Point Plant" If the Duty Call Supervisor does not call promptly, notify System Operations e_h Power Coordinator and tell him to call the personnel on the Duty Call Supervisor's Call List.

?

g,. - ~ - n, -

-- ~

.e

- -. -. ~,..

,r,.,.

r 6/10/82 EMERGENCY ROCEDURE 20101, PAGE 4 DUTIES OF F 4ERGENCY C00RDfNATOR i

8.7 As the emergency progresses.md additional infomation becomes available or as the situation changes, information applicable to the Emergency Infomaticn Checklist shoJ1d be relay 3d by telephone, NAWAS,and/or Local Government Radio (LGR) to' B.)P and Dada County Civil Defense.

If the Technical Support Center (TSL) is not staffed the infomation should be relayed by the Emergency Coordinator '(EC) or a designated comunicator.

8. 8 The notification to N'<C on the Emergency Notification System (ENS) shall be made within one hour of the declaration of the. emergency and should cont 61n, to the extent known, the infomation applicable to Appendix B of this procedure.

IUpcn a failure of the T;nergengency Notification System, immediately call the NRC comerciallyl.

Once the notification to the NRC

,[

via ENS, f or comercially n made, we are required by 10 CFR 50.72 to maintain an open channel of communication until the NRC grants pemission to hang up.

The EC shall designate an individual to maintain the open chain of communications as required.

8.9 When, during the course of the emergency, the seriousness of the condition changes so that the emergency fits into a different classification than it originally was reported as, the EC shall so notify the Emergency Control Officer (ECO), the BDP, and Dade County Civil Defense by teiephone, Nh/AS, and/or LGR.

The notifications may be made by the-TSC Supervisor or. a designated comunicator under the direction of the EC.

When the condition is recl assified, the EC shall switch to the appropriate part of the checklist for the new classification.

NOTE: This includes the case where a condition changes so that it no longer y

fits the classification of any emergency.

In other words, when the condition is no longer an emergency, the ECO, the BDP and Dade County Civil Defense shall be so notified.

8.10 Responsibility for Off-site Communications and Coordination shall be relinquished to the Emergency Control O'ficer when he establishes contact and assumes responsibility.

8.11 The Emergency Coordinator is responsible for providing Protective Action Recormiendations to off-site authorities as indicated on " Protective Action Recomendations Checklist".

When the Emergency Control Officer has indicated that the E0F is manned and operational, the Pecovery Manager can relieve the Emergency Coordinator of this responsibility.

/

w 1

n

.,a1-*

y-

+,-m,p.,,

,n.

..p-,s,,9 c.

i 6/10/82 EMERGENCY PROCEDURE 20101, PAGE 5 DUTIES OF EMERGENCY COORDINATOR UNUSUAL EVENT CHECKLIST Actions to be taken by Emeraency Coordinator in the event of an UNUSUAL EVENT 1.

Direct initial corrective action to mitigata the problem.

Fire / Explosion - see attached Fire / Explosion Checklist and Emergency Procedure 20107 ti Medical - see attached Medical Emergency Checklist 2.

Direct Nuclear Watch Engineer to mobilize interim Emergency Teams to respond if necessary.

3.

Complete the attached Emergency Infonnation Checklist.

4.

Relay infonnation to the Duty Call Supervisor (see NPS Bulletin Board for scheduled supervisor and telephone number). Direct him to notify the individuals on his call list in Emergency Procedure 20104, F.mergency Roster. Alternate - see Paragraph 8.6 of this procedure.

g-5.

Within fifteen minutes of declaration of emergency, notify, by_ NAWAS, the State Warning Point at the Bureau of Disaster Preparedness in Tallahassee and communicate Emergency Infnnnatinn Checklist data.

Alternate numbers are 6.

Within one hour notifv NRC via ENS hot-line. Alternate numbers are

_ _. ano Upon a failure of the Emergency Notification System, imediately call the NRC comercially at.

Use the attached Appendix B to make the notification. Do not liang~up until the NRC gives pemission.

7.

Reassess the Emergency Classification and update the Emergency Infomation Checklist, and notify BDP via NAWAS if necessary.

hg When the plant conditions no longer meet the definition of an unusual 8.

event or any other emergency condition, so notify the ECO and BDP by telephone.

4 e.

w

.\\

  • rM'my,** 7
  • sN ---

a---

s--

~

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 6 OUTIES OF EMERGENCY COORDINATOR C

ALERT CHECKLIST (Page 1 of 2)

Actions to be taken by Emergency Coordinator in the event of an ALERT 1.

Direct initial corrective action to mitigate the problem and bring the plant to a safe, stable condition.

(G Fire / Explosion - see attached Fire / Explosion Checklist and Emergency Procedure 20107 Medici - see attached Medical Emergency Checklist 2.

If evacuation of an area is necessary, notify personnel of the emergency condition over the page system, initiate a local evacuation in accordance with Emergency Procedure 20109, Criteria For and Conduct of Local Evacuation. Announce the following:

Area Affected Assembly Area 3.

Direct Nuclear Watch Engineer to mobilize interim Emergency Teams to py respond as necessary.

(w.

W 4.

lComolete the attached Emergency Information Checklistl.

5.

Relay information to the Duty Call Supervisor (see NPS Bulletin Board for scheduled supervisor and telephone number). Direct him to notify the individuals on his call list in Emergency Procedure 20104, Emergency Roster. Alternate - see paragraph 8.6 of this procedure.

6.

Within fifteen minutes of declaration of emergency notify, g lNAWASl, the State Warning Point at the Bureau of Disaster Preparedness in Tallahassee and communicate Emeroency Information Checklist data.

l Alternate numbers are 7.

lif the State Warning Point at the Bureau of Disaster Preparedness was M""

not notified by NAWAS, then notify NTense Office in Miami,__ _._ l, by telephone, the Dade County Civil

_ Land communicate Emergency Information Checklist data. Off hours, call 596-8176 or 911.

8.

IIf the State Warning Point at the Bureau of Disaster Preparedness was not notified by NAWAS, then notifyl, by telanhone the' Monroe County Msaster Preparedness office in Key West

', and communicate u

f Emergency Information Checklist data. Off hour g call.

9.

If local evacuation was conducted, verify from Security Team L der that all personnel are accounted for.

l-

\\

\\

o+

. s

\\

3.g.-,- m. mm

-=

[

6/10/82 EMERGENCY PROCEDURE 20101, PAGE 7 DUTIES OF EMERGENCY C00RDINATOR ALERT CHECKLIST (Page 2 of 2)

{t

10. Direct Shift Technical Advisor to activate the Technical Support Center.
11. Activate the Operational Support Center.
12. Within one hour notify NRC via ENS hot-line. Alternate numbers are

~

'Upon a failure of the Emern=c.y Notification System, imediately call the Nrc comercially at.

0550l. Use the attached Appendix B to make the notification. Do not hang up until the NRC gives permission.

13. Reassess the Emergency Classification and update the Emergency tc?

Infomation Checklist, and notify BDP via NAWAS with updated off-site v

dose information.

14. Brief the Technical Support Center Supervisor (nomally Technical Department Supervisor) on events. Direct him to provide State and County with periodic updates.
15. Reassess corrective and protective actions. Verify activities underway, reassign personnel and teams as necessary.
16. Reassess the Emergency Classification and update the Emergency Infomation Checklist with Technical Suppet Center Supervisor.

^

16. Relinquish control and communication responsibilities to the Emergency (e-Control Officer if he activates the Off-Site Organization.
17. When the plant conditions no longer meet the definition of an alert or any other emergency condition, so notify the ECO and BDP by telephone.

This notification may be made by the TSC, at the EC's discretion.

e.g e

+

n

\\

g w p m.,: y.- c ---.,,,.,-,

I 3/8/82 EMERGENCY PROCEDURE 20101, PAGE 8 DUTIES OF EMERGENCY COORDINATOR

(

SITE AREA EMERGENCY CHECXLIST (Page 1 of 2)

Actions to be taken by Emergency Coordinator in the event of SITE AREA EMERGENCY 1.

Order initial corrective action per Emergency Operating Procedures.

Fire / Explosion - See Attached Fire / Explosion Checklist and Emergency Procedure 20107

('S Medical - See Attached Medical Emergency Checklist 2.

If evacuation is necessary, notify personnel of the emergency condition over the PA system (crossconnect the page), giving location, class, and type of emergency, and order all non-essential personnel to commence evacuation of the Owner Controlled Area in accordance with Emergency Procedure 20110, Criteria for and Conduct of Owner Controlled Area Evacuation.

3.

If site evacuation is necessary, sound Site Evacuation Alarm.

4.

If site evacuation is necessary, repeat PA announcement.

5.

If site evacuation is necessary, order Security Team Leader to evacuate i.N Owner Controlled Area and to report personnel accountability as soon as d

possible.

6.

Direct Nuclear Watch Engineer to mobilize other interim Emergency Teams as necessary.

7.

lComolete the attached Emergency Information Checklist l.

8.

Relay infonnation to the Duty Call Supervisor (see NPS Bulletin Board for scheduled supervisor and telephone number). Direct him to notify the personnel on his call list in Emergency Procedure 20104, Emergency Roster. Alternate - see paragraph 8.6 of this procedure.

9.

Within fifteen minutes of declaration of emergency make NAWAS Announcement:

" State Warning Point Tallahassee, this is Turkey Point."

(State Warning Point will give a go-ahead) l" State Warning Point Tallahassee, this is Turkey Point"l l DELETED l l(Relay Emergency Information Checklist datal.

" Acknowledge, over."

"1 (If NAWAS is inoperable call BDP at, ~

g._

p7

-.~---.y.--~--

r- - -

.m 7 -

r -

6/10/62 ENERGENCY PROCEDURE 20101, PAGE 9 DUTfES OF EMERGENCY COORDINATOR

,e

'l_ ~

SITE AREA EMERGENCY CHECKLIST (Page 2 of 2) 10.

State Warning Point Acknowledgment Time:

(NAWAS announcement also serves to notify Dade and Monroe Counties and the State Department of Health and Rehabilitative Services).

11.

Turn on LGR, contact Dade County Civil Defense, infom them that site evacuation has started, (if it has) location of assembly area (s),

evacuation route (s). Notify them of any wind changes, and when evacuation is completed.

'N 12.

If site evacuation was necessary, verify that each operator on shift is uninjured and relay the operator's names and keycard nebers to Security Team Leader.

13.. Notifv HAFB, Command Post (using the direct line or.

if their services are required.

14.

If site evacuation was necessary, verify from Security Team Leader that Owner Controlled Area Evacuation is complete and that all personnel are accounted for.

15.

Direct Shift Technical Advisor to activate the Technical Support Center.

,. m

16. Activate the Operational Support Center.

%5

17. Within one hour notify NRC via ENS hot-line. Alternate numbers are

'lUpon a failure of the Emergency Notification System, immediately call the NRC commercially at _

Use the attached Appendix B to make the notification. Do not IIang~up until NRC gives permission.

18.

Reassess the Emergency Classification and update the Emergency I

Infomation Checklist and notify BDP via NAWAS with updated off-site dose infomation.

19.

Brief the Technical Support Center Supervisor (nomally the Technical Department Supervisor) on events. Direct him to update State and County p;cy g

periodically (EOF will perfom these updates when operational).

20. Reassess corrective and protective actions. Verify activities underway, reassign personnel and teams as necessary.
21. Relinquish Emergency Coordinator control and communications responsibilities to the Emergency Control Officer when he assumes the responsibilities.
22. When the plant conditions no longer meet the definitfon of Site Area Emergency, so notify the TSC Supervisor so that he can notify the ECO, who will notify BDP.

l @-

l p

8 e

9

=

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 10 DUTIES OF EMERGENCY COORDINATOR

(~

GENERAL EMERGENCY CHECKLIST (Page 1 of 3)

Actions to be taken by Emergency Coordinator in the event of GENERAL EMERGENCY 1.

Order initial corrective action per Emergency Operating Procedures.

2.

Notify personnel of the emergency condition over the PA system (crossconnect the page), giving location, class, and type of emergency.

I 3.

Order all non-essential personnel to commence evacuation of the Owner Controlled Area in accordance with Emergency Procedure 20110, Criteria for and Conduct of Owner Controlled Area Evacuation.

4.

Sound Site Evacuation Alarm.

5.

Repeat PA announcement.

6.

Order Security Team Leader to evacuate Owner Controlled Area and to report personnel accountability as soon as possible.

7.

Direct Nuclear Watch Engineer to mobilize other interim Emergency Teams as necessary.

,3

\\b 8.

Within fifteen minutes of declaration of emergency make NAWAS i

Announcement:

" State Warning Point Tallahassee, this is Turkey Point."

(State Warning Point will give a go-ahead)

I" State Warning Point Tallahassee, this is Turkey Point"l l(Relay Emergency Information Checklist Data)l l" Acknowledge, over."l

./

(If NAWAS is inoperable, call BDP at 9.

State Warning Point Acknowledgment Time:

(NAWAS announcement also serves to notify Dade and Monroe Counties and the State Department of Health and Rehabilitative Services.)

4 F.

s 5

l-

)

y.,

f 3/8/82 EMERGENCY PROCEDURE 20101, PAGE 11 DUTIES OF EMERGENCY COORDINATOR l'

GENERAL EMERGENCY CHECKLIST (Page 2 of 3) 10.

Complete Emergency Information Checklist including off-site dose projections using Emergency Procedure 20115, Radiation Release and Dose Projection.

11. Make NAWAS Announcement:

/ '

" State Warning Point Tallahassee, this is Turkey Point."

(State Warning Point will give a go-ahead).

l" State Warning Point Tallahassee, this is Turkey Point"l l(Relay Emergency Information Checklist datall

" Acknowledge, over."

12. State Warning Point Acknowledgment Time:
13. Relay information to the Duty Call Supervisor (see NPS Bulletin Board for scheduled supervisor and telephone number). Direct him to notify the personnel on his call list in Emergency Procedure 20104.

Alternate: see Section 8.6 of this procedure.

14.

Turn on LGR, contact Dade County Civil Defense, inform them that site evacuation has started, location of assembly area (s), evacuation route (s). Notify them of any wind changes, and when evacuation is completed.

?

- '~ s

. cs y

l

.I

[

[YE I,"

' ~"

6/10/82 EMERGENCY PROCEDURE 20101, PAGE 12 DUTIES OF EMERGENCY COORDINATOR GENERAL EMERGENCY CHECXLIST (Page 3 of 3)

15. Verify that each operator on shift is uninjured and relay names and keycard nisnbers to Security Team Leader.
16. Notify HAFB Command Post - direct line,.
17. Verify from Security Team Leader that Owner Controlled Area Evacuation is complete and that all personnel are accounted for.
18. Order Shift Technical Advisor to activate the Technical Support Center.

b^.n f'

19. Activate the Operational Support Center.
20. Within one hour notify NRC via ENS hot-line. Alternate numbers are iUpon a failure of the EmeraencY Notification System. immediately call the NRC commercially at.

0550l.

Use the attached Appendix B to make the notification. 'Uo not "

hang up until NRC gives permission.

21. Brief the Technical Support Center Supervisor (nonnally the Technical Department Supervisor) on events. Direct him to update State and County periodically.

(EOF will perform these updates when operational.)

/%

22. Reassess corrective and protective actions. Verify activities underway, be reassign personnel and teams as necessary.
23. Reassess the Emergency Classification and update the Emergency Information Checklist with the Technical Support Center Supervisor.

~

24. Relinquish control and communications responsibilities to the Emergency Control Officer when he assumes the responsibilities, i
25. When the plant conditions no longer meet the definition of General Emergency, so notify the TSC Supervisor so that he can notify the ECO, i

who will notify BDP.

61 4

l.@

l 7,,4_ ___;...,,,.., _.._..

..__._...._m_

a 3/8/82 EMERGENCY PROCEDURE 20101, PAGE 13 DUTIES OF EMERGENCY COORDINATOR TABLE 1 (Sheet 1 of 3)

EMERGENCY INFORMATION CHECKLIST ESSAGE FORM FOR NOTIFICATION TO THE STATE OF FLORIDA DATE AND TIME OF MESSAGE 1.

_ SITE 2.

ACCIDENT CLASSIFICATION 3.

UNIT MlMBER(S)

B ST. LUCIE A

UNUSUAL EVENT A

ONE (1)

Y TURKEY POINT T

ALERT T

TWO (2)

C SITE AREA EERGENCY C

THREE(3)

T GENERAL EMERGENCY N

FOUR (4) 4.

TINE AND DATE OF INCIDENT / EVENT:

TIME DATE 5.

INCIDENT INVOLVES:

6.

SITUATION INVOLVED:

7.

TYPE OF RELEASE IS:

A NO RELEASE A

RADI0 ACTIVE GASEOUS T

POTENTIAL (POSSIBLE) RELEASE I

NON-RADIOACTIVE GASEOUS I

IMINENT (PROBABLE) RELEASE T

RADI0 ACTIVE LIQUID L.

E A RELEASE IS OCCURRING V

NON-RADI0 ACTIVE LIQUID T

A RELEASE THAT OCCURRED, BUT STOPPED T

NON-APPLICABLE 8.

RECOMENDED PROTECTION ACTIONS:

@l FOR INFORMATION ONLY - (UNUSUAL EVENT OR ALERT)

[Bl PREPARE FOR POSSIBLE ACTION INVOLVING THE PUBLIC, TO INCLUDE NOTIFICATION.

(ALERT OR SITE AREA EMERGENCY) lCl NOTIFY PUBLIC TO TAKE THE FOLLOWING PROTECTIVE ACTIONS. (SITE AREA OR GENERAL EMERGENCY)

NO ACTION SHELTER EVACUATE l_l lDJ

@l 0-2 MILE RADIUS (GASEOUS RELEASE) b'E l_l

@l Ql 2-5 MILES FOR SECTORS (GASEOUS RELEASE) l_l

@l

[dl 5-10 MILES FOR SECTORS (GASEOUS RELEASE) lGl

$l MILES l,Q DISCONTINUE USE OF POTENTIALLY AFFECTED WATER IN LOCATIONS 9.

RELEASE IS:

@l CONTINUING - EXPECTED DURATION OR MAGNITUDE

[Bl TERMINATED - APPROXIMATE DURATION OR MAGNITUDE 67 B

b2 l

\\

7g.,., -...

^

-i s

3/8/82 EMERGENCV PROCEDURE 20101, PAGE 14 DUTIES OF EMERGENCY C0ORDINATOR TABLE 1

{

(Sheet 2 of 3)

EMERGENCY INFORMATION CHECKLIST

10. REPORT OF GASEOUS RELEASE IS:

@l GROUND LEVEL

11. WIND SPEED:

MILES PER HOUR

12. WIND DIRECTION DATA (CHECK ONE, READ ACROSS)

WIND FROM DEGREES WIND TOWARD SECTORS AFFECTED A ---N------------34 9-11 -------------S-----H J K T ----NNE--

12-33--

SSW - --

JKL C -----NE--

--34-56----

-SW-KLM f

N --ENE---

--57-78


WSW LMN i

T ----E-101 W

--M N P T --E S E---

-102-123---

L'W

-NPQ l - --SE-


124-146

-NW PQR R

-SSE---

-147-168 - - -

"W-

--Q R A J

S --

169-191

--R A B Y

SSW-192-213

--NNE-

---A B C T

-SW

- 214-236-

-NE

-B C D R ---WSW 237-258----

ENE-CDE R

W 259-281 - -

-E-9EF 7 - - WNW 282-303-ESE--

EFG l ---NW

-304-326 SE-

-F G H R

NW

- - - 327-348 SSE------G H J

(..

13. CURRENT OUTSIDE TEMPERATURE:

@[

  • F
14. WEATHEk CONDITIONS (RAIN, SNOW, SLEET, ETC.):
15. TEMPERATURE DIFFERENCE (DELTA T):

l_Al

'F ELEVATION OF TEMP. DIFFERENCE MEASUREMENT:

STABILITY CLASS (IF KNOWN)

16. RELEASE DETECTED BY:

A VISUAL T

SAMPLE RESULTS ARE:

Y INSTRtMENTATION--


LOCATION

-RELEASE RATE (Ci/sec)

.d

-j: 17. ACCIDENT RELATED INJURIES:

@l NO lB,l YES NLMBER OF INJURIES

18. OTHER INFORMATION:
19. MESSAGE REPORTED BY:

NAME ORGANIZATION TELEPHONE (0UTSIDE a)

20. MESSAGE RECEIVED BY:

YOUR NAME TIME DATE g.-

CONTINUE TO NEXT PAGE FOR:

Ef 1)

PLANT DUTY SUPERVISOR 2)

EMERGENCY CONTROL OFFICER / RECOVERY MANAGER / NUCLEAR ENERGY DUTY OFFICER 3)

DHRS RADIOLOGICAL DUTY OFFICER y-.y

.,n..-,.,....

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 15 DUTIES OF EMERGENCY COORDINATOR TABLE 1 (Sheet 3 of 3)

EMERGENCY INFORMATION CHECKLIST ADDElEXM TO ESSAGE FORM FOR NOTIFICATION TO THE STATE OF FLORIDA 1.

DATE Ale

/

/

TIME OF MESSAGE 7"

2.

ASSESSMENT OF THE EERGENCY (INCLUDING POTENTIAL FOR ESCALATION TO HIGHER CLASS) 3.

BASIC DESCRIPTION OF THE EVENT n-4.

ESTIMATE OF RADI0 ACTIVE MATERIAL RELEASED (GASEOUS):

NOBLE GASES:

SOURCE TERM:

Ci/Sec TOTAL RELEASE:

C1 RADI0 IODINES:

SOURCE TERM:

C1/Sec TOTAL RELEASE:

Ci t

n 5.

ESTIMATE OF PROJECTED OFFSITE DOSE RATES:

N DISTANCE

  • THYROID WHOLE BODY (mrem /hr)

(mrem /hr) 1 mile (site boundary) 2 miles l

5 miles 10 miles f'Q" r

  • Adult thyroid dose commitment - the accumulated dose body burden to an adult from

~

fnhalation of radiciodine for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> duration.

)

J t

7 OW_p"Y T..MrrW PP q"'_ mT".5'~*". = 7per* "- ~ '- ~- ~~ ~

s -?':'r':

t

_ ru m.4,.:pf :

~.

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 16 DUTIES OF EMERGENCY COORDINATOR PROTECTIVE ACTION RECOMMENDATIONS CHECKLIST FPL is required to provide BDP with recomendtions for protective actions to be taken by off-site personnel during an emergency condition. Until the EOF is staffed and functional following declaration of the emergency, the EC is responsible for providing the state with these 'ecomendations. Due to the extremely large political and legal ramifications of these recommendations and their very large potential impact on FPL, the format and content will be strictly adhered to as described below.

The contents of the recommendations are to be determined by using figures A-1 through A-5 of this procedure as follows:

1.

If the eme gency has been classified as a GENERAL EMERGENCY and No Off-Site dose estimates or field survey results are available, refer to Figure A-1 through A-3 to evaluate off-site protective action recommendations.

NOTE:

If a controlled release is necessary to stabilize plant conditions or an uncontrolled release is anticipated, determine the approximate source term and duration of the release and the projected off-site doses prior to making any protective action recomendations.

2.

If the emergency has been classified, and the off-site doses are LESS THAN 0.5 Rem whole body or 1 Rem to the thyroid at 1 mile over the projected duration of the release, no protective action is recomended. This should be reported to BDP and other outside agencies who inquire as:

I

(

" Based on our current assessment of all the infonnation now available to us, Florida Power and Light recomends that you consider taking the following protective actions (PA) - NONE. This recomendation may change in the future, but we cannot now say when it may change or what it may change to."

l NOTE:

Off-site dose values are calculated from Emergency Procedure 20126, Off-l site Dose Calculations, and/or field monitoring results.

3.

If the emergency has been classified and off-site dose information is available (from any credible source), use the dose information to enter the appropriate estimated off-site table in Figure A-2 (PA with off-site dose estimates for greater than or equal to 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> duration) or Figure A-3 (PA with off-site dose j

estimates for less than 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> duration). The appropriate recomendations can l

c then be made. For example, a release has occurred at the St. Lucie Plant with a

('.

projected duration of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, the wind direction is from the NNE and the projected off-site integrated (2 hr) thyroid dose is 10 Rem at 1 mile, 2 Rem at 2 miles, and less than 1 Rem at 5 miles. Referring to Figure A-2 (PA with off-site dose estimates for greater than or equal to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> duration) the following recomendation should be made:

" Based on our current assessment of all the information now available to us, Florida Power and Light Company recomends that you consider taking the following protective actions:

(1)

Evacuate all personnel between a 0 and 2 miles radius from the plant.

sr by (2)

Shelter all personnel between a 2 and 5 mile radius from the plant who are in sectors J, K and L (refer to Emergency Information Checklist).

This recomendation may change in the future, but we cannot now say when it may change or what it may change to."

2WWT@f7 "E"U" !

7" ~PF"P"E "U

"~~~ ~ ~ ~ "

3/@/82 EMERGENCY PROCEDURE 20101, PAGE 17 o

DUTTES OF EMERGENCY COORDINATOR 4.

When available, both plume calculations and off-site monitoring results should be evaluated when making these protective action reconsnendations.

If significant discrepancies exist between field monitoring results and plume dispersion calculations, then an evaluation of the discrepancy should be made, and the appropriate value shauld be selected in the determination of protective action reconsnendations.

5.

For other emergency conditions which may occur, enter the table for those conditions, determine the reconsnended protective actions and formulate the appropriate message in the above format and transmit it to BDP.

6.

Protective action reconsnendations for a child have been incorporated into the figures.

9 i

/

k.',#7 p.,_.--,,_

7_...

..y,,

y..

g,...p

,.3..,__.,.,

s.

=.; w

,y..,

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 18 DUTIES OF EMERGENCY COORDINATOR FIGURE A-1 PROTECTIVE ACTION RECOMMENDATIONS BASED ON PLANT CONDITIONS (To Be Used Only When Off-Site Dose Projections Are Not Available)

GENERAL NO Line 1 EMERGENCY t,.

YES LOSS OF CHRRM NO CONTAINMENT NO Line 1

> 10 R/hr INTEGRITY

  • YES YES Go to Figure A-2 Line 1

(._

A-2 e

LINE 0-2 MILES 2-5 MILES 5-10 MILES 1

N N

N 2

S(CR)

S (DW)

N 3

E (CR)

E(DW) + S(RS)

E(DW) + S(RS) 4 E (CR)

E (CR)

E(DW) + S(RS)

LEGEND OF ABBREVIATIONS N = No Protective Action Recomended S = Sheltering Recommended

/*E = Evacuation Recommended

'wri DW = Downwind Sector + 2 Adjoining Sectors RS = Remaining Sectors CR = Complete Circle Around Plant at Specified Distance

  • Loss of Containment Integrity assumes greater than allowable Technical Specification leakage but less than 400 times this value.

s, U.rzzzi:

1 1 2 r :J a r ~ N "~ r "E

d a

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 19 DUTIES OF EMERGENCY COORDINATOR FIGURE A-2 PROTECTIVE ACTION RECOMMENDATIONS BASED ON PLANT CONDITIONS (To Be Used Only When Off-Site Dose Projections Are Not Available)

LOSS OF CHRRM NO CONTAINMENT NO Line 1

> 100 R/hr INTEGRITY YES I

Line 2 l

YES LOSS OF CHRRM NO CONTAINMENT NO Line 1

> 2.00 x 104 INTEGRITY R/hr YES YES Go to Table A-3 Line 4 A-3 LINE 0-2 MILES 2-5 MILES 5-10 MILES 1

1 N

N N

2 S(CR)

S (DW)

N 3

E (CR)

E(DW) + S(RS)

E(DW) + S(RS) 4 E(CR)

E (CR)

E(DW) + S(RS)

LEGEND OF ABBREVIATIONS N

No Protective Action Reconrnended

=

S Sheltering Recommended

=

( ~- = Evacuation Reconinended

(.JW = Downwind Sector + 2 Adjoining Sectors i

RS = Remaining Sectors CR = Complete Circle Around Plant at Specified Distance n.-

s

.)

-~

\\-nv c-e-h :- - ' ~~ ~

3-

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 20 DUTIES OF EMERGENCY COORDINATOR l

FIGURE A-3 PROTECTIVE ACTION RECOMMENDATIONS BASED ON PLANT CONDITIONS (To Be used Only When Off-Site Doce Projections Are Not Available)

A-3 f

LOSS OF CHRRM NO CONTAINMENT NO Line 2

> 1.0 x 105 INTEGRITY R/hr YES l

Line 4 l

YES LOSS OF CONTAINMENT NO Line 3 INTEGRITY f

YES Line 4 LINE 0-2 MILES 2-5 MILES 5-10 MILES 1

N N

N 2

S (CR S (DW)

N 3

E(CR E(DW) + S(RS)

E(DW) + S(RS) 4 E (CR E (CR)

E(DW) + S(RS)

"..EGEND OF ABBREVIATIONS N

No Protective Action Recommended

=

S Sheltering Recommended

=

E Evacuation Recomended

=

DW = Downwind Sector + 2 Adjoining Sectors RS = Remaining Sectors CR = Complete Circle Around Plant at Specified Distance f

e y. ~, ~ -,.

  • ~

,s

.. q

"*}

[

EMERGENCY PROCEDURE 20101, PAGE 21 DUTIES OF EMERGENCY COORDINATOR FIGURE A-4 PROTECTIVE ACTION RECOMMENDATIONS BASED ON ACTUAL RELEASE (GREATER THAN OR EQUAL TO 2 HOUR DURATION) WITH OFFSITE DOSE ESTIMATES (used in preference to Figure A-1 through A-3)

OR WHOLE BODY THYROID DOSE DOSE (REM)

(REM) 0-2 MILES; 2-5 MILES; 5-10 MILES; USE 1 MILE USE 2. MILE-USE 5 MILE VALUE VALUE VALUE

< 0.5

< 1,0 N

N N

1 0.5

> 1,0

'"Io

)l}g S(CR)

S(DW)

S(DW) 1 1.0

- 1 5.0 E(CR)

E(DW) +

E(DW) +

<50 o

S(RS)

S(RS) l 1 5.0

> 25.0 E(CR)

E(CR)

E(DW) +

l S(RS)

,G l

S.,

NOTE:

If the duration of the release is projected to be less than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, use Figure A-5.

  • The dose @ 1 mile affects protective actions LEGEND OF ABBREVIATIONS i

from 0-2 miles l

N - No protective action recomended The dose @ 2 miles effects protective actions S - Sheltering recommended i

from 2-5 miles E - Evacuation recomended f.

l (7The dose @ 5 miles effects protective actions DW-Downwind sector + 2 adjoining i

from 5-10 miles sectors l

The dose @ 10 miles can be used to evaluate RS-Remaining sectors protective actions for greater distances.

CR-Complete circl5 around plant at specified distance i

I i

,,,,,.~4

-r +

~.

,.,,y,.

.pg, we m

.gt g p, f

,7

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 22 DUTIES OF EMERGENCY COORDINATOR FIGURE A-5

  • ~

PROTECTIVE ACTION RECOMMENDATIONS BASED ON ACTUAL RELEASE

~

(LESS THAN 2 HOUR DURATION) WITH OFFSITE DOSE ESTIMATES (used in preference to Figure A-1 through A-3)

WHOLE BODY THYROID DOSE DOSE (REM)

(REM) 0-2 MILES; 2-5 MILES; 5-10 MILES; USE 1 MILE USE 2 MILE USE 5 MILE VALUE VALUE "

VALUE -

\\.

< 0.5

< 1.0 N

N N

1 0.5

> 1.0 but

_but S(CR)

S(DW)

S(09)

< 1.0

< 5.0

> 1.0

> 5.0 lut Ibut S(CR)

S(CR)

S(CR)

-< 5.0

< 25.0 1 5.0 1 25.0 E(CR)

E(DW) +

E(DW) +

S(RS)

S(.RS)

. NOTE:

^ If the duration of the release is projected to be less than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, use Figure A-4

  • The dose @ 1 mile affects Protective Actions LEGEND OF ABBREVIATIONS from 0-2 miles N - No protect'ive action recomended The dose @ 2 miles affects Protective Actions from 2-5 miles S - Sheltering recomended i

t E - Evacuation recomended The dose @ 5 miles affects Protective Actions from 5-10 miles DW-Downwind sector + 2 adjoining sectors hyThedose@10milescanbeusedtoevaluate RS-Remaining sectors

" Protective Actions for greater distances.

CR-Complete circle around plant at specified distadce i

i pyy :~.-~;"w.3V W

  • " ' ~ ' ~ ' '

.n.

-.--->-v~n

,mm., egwm ' $

v

.. ~.

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 23 DUTIES OF EMERGENCY COORDINATOR iT FIRE OR EXPLOSION EMERGENCY CHECKLIST TIME

_ Crossconnect page to all units and sound fire alarm.

Make page announcement: "This is not a drill.

This is not a drill," and give the location and classification of the fire / explosion. Then announce, "All personnel in the fire area withdraw to a safe location.

Activate any other appropriate Emergency Teams - as needed Dade County Fire Department - 911 See EP 20107 concerning when to call Dade County HAFB Direct line to command post.

(See EP 20107 concerning when to call HAFB)l Return to appropriate IUNUSUAL EVENTI, ALERT, SITE AREA EMERGENCY, or GENERAL EMERGENCY checklist.

rc

.; s I

l l

l l

[L.

~

l l

l l

6 Q

M4 W**

7 7

F* 4 "P*T - ' * * " * ' '

^-"

"*#~'*

'M

- 8 * ~1

FN'N D

f

  • [' D. '*

y

3/12/82 EMERGENCY PROCEDURE 20101, PAGE 24 DUTIES OF EMERGENCY COORDINATOR

'g MEDICAL EMERGENCY CHECKLIST

{_

TIME Determine:

Name of Victim Employer (if not FPL)

Nature and Extent of Injury Location Is victim contaminated Ensure Victim gets first aid by:

Sending N.W.E. and extra operator to scene and activating First Aid and Personnel Decontamination Team (Notify Radiochemist or Chemistry Supervisor f-f('

at c on Bell phone or,

on PAX phone).

NOTIFY:

Health Physics PAX BELL Site Manager PAX BELL Plant Manager-Nuclear PAX

(

BELL l

When detemined, notify Captain of Guard where to direct ambulance, etc.

RADIO (CHANNEL 1)

PAX BELL Nuclear Plant Supervisor should:

'h-1.

Determine mode of transportation based on nature and extent of injuries.

(Ensure victim's TLD, selfreader, ID badge and key card are retained on site).

a)

Imediate life threatening condition.

DADE COUNTY FIRE RESCUE PHONE:

HOMESTEAD AIR FORCE BASE 3 and 4 Direct Tie Line Phone b)

Medical transportation for serious inhu-RANDLE EASTERN AMBULANCE PHONE:

BECHTEL AMBULANCE PHONE:

c)

Medical treatment for minor injuries:

g FPL Vehicle - Call Maintenance Supervisor u

l 2.

Decide where to send victim and notify them he is coming.

a)

Non-radioactively contaminated victims:

Send to CORAL REEF GENERAL HOSPITAL PHONE: 2 b) Radioactively contaminated victims send to:

See EP 20101 - Appendix A

" REEF Notification" l

MT. SINAI HOSPITAL (primary)

PHONE:

BAPTIST HOSPITAL (backup)

PHONE:

(Radiation Protection Man should accompany the victfin to the

' g hospital) 3.

If Site Manager not available, notify Administrative Assistant (PAX.

. ___kor Duty Call Supervisor - See Emergency Roster.

Site Manager and/or the Administrative Assistant will handle off-site notifications.

!o s

....l

..g

.1-p.

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 25 DUTTES OF EMERGENCY COORDINATOR APPENDIX A REEF NOTIFICATION In the event of a radiation emergency which requires the transportation of casualties to REEF, located within Mt. Sinai Hospital, the Emergency Coordinator shall transmit the following information, if it is available:

1.

Name of casualty being transported 2.

Types of injuries involved and body part:

h.

a.

Fractures b.

Burns c.

Hemorrahaging d.

Other e.

Anbulatory:

Yes No 3.

Radiation contamination status:

a.

Type of instrument used b.

BEFORE AFitR DECONTAMINATION DECONTAMINATION BODY PART C/M C/M 1.

2.

~f.7 3.

w;p 4.

5.

c.

Radioisotopes involved d.

Decontamination procedures used (c. l..

4.

Type of transporting vehicle 5.

Time of departure from. plant

's I

b x===:::=

==.

=~

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 26 DUTTES OF EMERGENCY COORDINATOR APPENDIX B CHECKLIST FOR NOTIFICATION OF SIGNIFICANT EVENTS MADE IN ACCORDANCE WITH 10 CFR 50.72 A.

Identification:

Date:

Time:

Name of Person Making Report:

g:

ENS or Bell Phone:

Name of Person Contacted:

License: Florida Power and Light Co. Facility Affected: Turkey Point Unit Applicable Part of 10 CFR 50.72:

Activation of Emergency Plans B.

==

Description:==

Date of Event:

Time:

Trip Number:

Description of What Happened:

w C.

Consequences of Event:

(Complete depending on type of event)

(

.l Injuries:

Fatalities:

Contamination (personnel):

(property):

Overexposures (known/possible)

Safety Hazard (describe - actual / potential)

C.

?

l i

1 x x = r : _ L ------ -

z=:=r-m

e t

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 27 DUTIES OF EMERGENCY COORDINATOR APPENDIXB(cont'd)

CHECKLIST FOR NOTIFICATION OF SIGNIFICANT EVENTS MADE IN ACCORDANCE WITH 10 CFR 50.72 C.

Consequences of Event:

(Complete depending on type of event) (cont'd)

Offsite Radiation Levels:

Integrated Dose:

Location:

Meterology (wind speed):

From (direction):

Weather Conditions (rain, clear, overcast, temperature):

Equipment / Property Damage:

D.

Cause of Event:

N.

E.

Licensee Actions:

Taken:

Planned:

l Emergency Plan Activated (Yes/No):

Classification of Emergency

([.

Resident Inspector Notified (Yes/No):

State Notified (Yes/No):

Press Release Planned (Yes/No):

News Media Interest (Yes/No):

I Local / National:

TO BE COMPLETED BY PLANT MANAGER - NUCLEAR (or his designee) i i

e e

IUnusual Event, Alert, Site Area Emergency, or General Emergency i

I 6

i q,

,*~~';.'"~' ~*~

~ '~ "

~

~ - ~ ' *

  • * " M *m****V~ ~ *~ Tyq"

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 23 DUTTES OF EMERGENCY C00RDfNATOR APPENDIX B (cont'd)

CHECKLIST FOR NOTIFICATION OF SIGNIFICANT EVENTS MADE IN ACCORDANCE WITH 10 CFR 50.72 F.

Current Status:

(Complete depending on type of event) 1.

Reactor Systems Status:

Power Level Before Event:

After Event:

Pressure:

Temp. (thot)

(tcold RCS Flow (Yes/No)

Pumps On (Yes/No)

Heat Sink: Condenser Steam Atm. Dump Other Sample Taken (Yes/No):

Activity Level:

ECCS Operating (Yes/No):

ECCS Operable (Yes/No):

lEngineered Safety Featurel Actuation (Yes/No):

PRZ or RX Level:

Possible Fuel Damage (Yes/No)

S/G Levels:

Feedwater Source / Flow:

Containment Pressure:

Safety Relief Valve Actuation (Yes/No)

Containnent Water Level Indication:

Equipment Failures:

Normal Offsite Power Available (Yes/No):

/ '

Major Busses / Loads Lost:

Safeguards Busses Power Source:

D/G Running (Yes/No)

Loaded (Yes/No) 2.

Radioactivity Release:

Liquid / Gas Location / Source:

Release Rate Duration:

Stopped (Yes/No)

Release Monitored (Yes/No)

Amount of Release Tech Spec. Limits Radiation Levels in Plant Areas Evacuated ye

.wm-

--s-.-

3/8/82 EMERGENCY PROCEDURE 20101, PAGE 29 DUTIES OF EMERGENCY COORDINATOR APPENDIX B (cont'd)

CHECKLIST FOR NOTIFICATION OF SIGNIFICANT EVENTS MADE IN ACCORDANCE WITH 10 CFR 50.72 3.

Security / Safeguards 2 Bomb Threat:

Search Conducted (Yes/No)

Search Results:

t Site Evacuated (Yes/No)

Intrusion:

Insider Outsider Point of Intrusion Extent of Intrusion Apparent Purpose Strike / Demonstration:

Size of Group Purpose Sabotage:

Radiological (Yes/No)

Arson (Yes/No)

Equipment / Property Extortion: Source (phone, letter, etc.)

Location of Letter Demands General: Firearms involved (Yes/No)

Violence (Yes/No)

Control of Facility Compromised or Tnreatened (Yes/No)

Stolen / Missing Material Agencies Notified (FBI, State Police, Local Police, etc.)

(

Media Interest (present, anticipated)

TO BE COMPLETED BY PLANT MANAGER - NUCLEAR (or designee) f 4.

Other Coments:

i I

2See10CFR73.71(c) f

(. ~

t j

.7 -

..,.,..y.

...,,, _;y

.,.m.7._

P FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNITS 3 AND 4 EMERGENCY PROCEDURE 20105 JUNE 24, 1982

1.0 Title

ON-SITE SUPPORT CENTERS 2.0 Anoroval and List of Effective Paoes:

2.1 Aporoval

Change dated 6/24/82 Reviewed by PNSC June 24, 1982 Approved by h /

wePlant Mgr-Nuclear, M /8 19 P2-Approved by Vice President of 82

/ ' Nuclear Energy 7-f/

19 V

2.2 List of Effective Pages:

Page Date Page Date Page Date

(

1 6/24/82 3

3/26/81 5

3/26/81 2

3/26/81 4

6/24/82

3.0 Scope

r

3.1 Purpose

This procedure provides guidelines and responsibilities for activation and use of the on-site interim Technical and Operational Support Centers.

This procedure describes interim facilities and shall be revised when permanent facilities are operational.

3.2 Discussion

The activities of plant management, ~ technical, and engineering support personnel are an important part of the overall site response to 'an accident, and must be properly defined and logistically supported.

The need for additional operational support peMonneli, other than those required and allowed in the control room, is also recognized as vitally important in properly responding to an emergency.

The intent of providing Technical and Operational Support Centers is to provide bases where post-accident emergency planning can be conducted and required operational support personnel can assembly for potential duty.

Both centers will be in close communication with the Control Room via the PAX phone system.

QI 48 g

t---

7-..~

f.-

.y. - y..

-f m

3/26/81 EMERGENCY PROCEDURE 20105, PAGE 2 ON-SITE SUPPORT CENTERS S

3.3

Description:

3.3.1 Interim Technical Support Center (TSC)

The Interim TSC is located in a doublewide trailer within the plant Protected Area.

The available space is adequate to provide sufficient working space for appropriate plant personnel and-five NRC personnel.

3.3.2 Operational Support Center (OSC) 4 The OSC is maintained in the South Assembly Room in the site administration building.

PAX telephone communications are available between the OSC and the Control Room.

4.0 Precautions

4.1 The Interim TSC and OSC shall be activated upon the direction of the Emergency Coordinator or his designated alternate only.

4.2 Radiological conditions in the Interim Technical and Operational Support Center shall be monitored when required to be in use.

4.3 The Emergency Coordinator shall recommend a suitable location other than the designated areas if radiological conditions warrant such actions.

y

'~

5.0 Responsibilities

5.1 The Emergency Coordinator is responsible for activating the Interim TSC, activating the OSC, and arranging for staffing through the Duty Call Supervisor.

5.2 The Technical Support Center Supervisor will be the Technical Department Supervisor or his designee.

The Technical Support Center Supervisor is responsible for supervising TSC activities, reporting to the Emergency Coordinator, and communicating with the Interim Emergency Operations Facility, and other locations as directed

(? '

by the Emergency Coordinator.

5.3 The Shift Technical Advisor is responsible for, at the direction of the Emergency Coordinator, activating the TSC.

5.4 Each department head or designated alternate is responsible for reporting to the Interim Technical Support Center when called.

p

?=

q,1 3,.,..;-.

,7

w EMERGENCY PIOCEDURE E0105, PAGE 3 ON-SITE SUPPGRP CD7TERS 5.5 Personnel reporting to the Operational Support Center are responsible for being prepared to carry out support functions designated by the E:rergency Coordinator.

5.6 2e Emergency Coordinator has the overall responsibility for the conduct cf emergency operations and activities and should work closely with the Technical Support Center to encu e all information is used in making accident recovery decisions.

S.7 he QC Department is. responsible for ensuring that necessary records, documents, and prints are maintained.in the Technical Support Center or are

,J available for immediate use in the Document Control vault.

\\

6.0

References:

6.1 'Iurkey Point Emergency plan 6.2 Emergency Procedure 3101, Duties of the Emergency Coordinator 6.3 Emergency Procedure 2103, Classifications of Emergencies 7.0 Pecords and Notifications:

A record of actions taken at the Interim TSC shall be maintained by the TSC Supervisor.

U

8.0 Instructions

/

8.1 Activation v

2e Emergency Coordinator shall activate' the Interim TSC and the OSC for any-

~

emergency condition classified as Alert, Site Area Emergency, or General Emergency.

/

8.2 Staffing he Emergency Coordinator shall arrange for staffing through the Duty Call Supervisor.

Se Shift Technical Mvisor shall, at the direction of the f

Emergency Coordinator, activate the Interim TSC.

'e*

4

[

l'

?

/

s

-W j4 e

f f

,c8 e

dB ww.

( g*N--*4 a'

  • w="

?

g

  • y
- F** *' $

$*e

} (* 4Dp W W-

"

  • py*g*

g4d""'y 4

.~m,'e

- 9p79

^pp,*fE*'r G'It

    • E'*$""
W4D 5W*.

y. :w u-y

,;v

6/24/82 EMERGEtlCY PROCEDURE 20105, PAGE 4 Oti-SITE SUPPORT CENTERS o

8.3 Radioloaical Sucolies The Interim TSC contains emergency. radiological monitoring eouipment and suppl ies, and respiratory protective devices.

Table 1 details these suppl ies.

8.4 Technical Data The document control center where pertinent records and drawings are available is located in the I and C Building, approximately 50 feet northwest of the Interim TSC.

(

8.5 Use of the Interim TSC 8.5.1 The TSC Supervisor and supporting TSC staff shall maintain communications with the Control Room and provide technical support as required by the Framancy Coordinator.

8.5.2 The TSC staff shall communicate with the General Office Emergency Center or Interim Emergency Operations Facility as necessary.

This shall incl ude relaying messages between those facilities and the Control Room.

8.5.3-The TSC staff shall direct itself toward determining current and projected plant status for orderly implementation of Emergency Plans and Procedures.

t 8.6 Use of the Ooerational Sucoort Center Personnel en Emergency Teams shall initially report to the OSC.

Personnel reporting to the OSC shall maintain communications with the Control Room and report as directed by the Emergency Coordinator or TSC Supervisor.

8.7 Deactivation It is the responsibility of the Emergency Coordinator or his designee to deactivate and secure the Interim TSC and OCS when the emergency condition no longer exists.

8.8 Alternate OSC In the event that the OSC becomes untenable, Ithe alternate 0.S.C. will be the Nuclear I and C Buildino or other location desionated by the Emergency Coordinatorl.

P'

,7

_,._,y_,_

EMEMENCY PROCEDURE 20103, PAGE 5 3/26/81 ON-SITE SUPPORP CENTERS TABLE 1 TECHNICAL SUPPORT CENTER EMERGENCY EQUIPMENT QUANTITY Dose Rate Meter 1

Frisker (Count Rate Meter) 1 Air Sanpler 1

0-500 Dosimeter Z

Dosimeter 01arger 2

Air Sanple Head 2

Particulate Air Sanplers 3 boxes Charcoal Air Sanplers 1 sheet Scott Respirators 6

Iodine Canisters 12 Silver Zeolite Cartridges 6

4 I

t 9

6

.O 4,

  • P N'

Y,,

l

}

['

,_4 m

4 E

w

  • s j

k e

g g.

(

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNITS 3 AND 4 EMERGENCY PROCEDURE 20106 JUNE 10, 1982

1.0 Title

NATURAL EMERGENCIES 2.0 Approval and List of Effective Pages:

2.1 Approval

Change dated 6/10/82 Reviewed by PNSC June 10, 1982 Approved by tcac P1 ant Mgr-N, MN 19 Fr2-r y

b 8/

1982.

Approved by N clear ergy V

j

2. 2 List of Effective Pages:

I Page Date Page Date Page Date Page Date 1

6/10/82 4

2/4/82 7

3/26/81 10 3/26/81 2

3/26/81 5

6/10/82 8

3/26/81 11 3/26/81 3

3/26/81 6

6/10/82 9

3/26/81 12 3/26/81

3.0 Scope

3.1 Purpose

This procedure provides instructions to be followed upon notification of a potential natural emergency or upon occurrence of an actual natural emergency.

3.2 Discussion

3.2.1 The natural emergencies considered in this procedure are those associated with weather disturbances such as hurricanes or tornadoes.

The geographical location of the area is such that the occurrence of other types of natural emergencies is highly improbable. However, flooding of the low lying areas surrounding the plant site could occur due to the torrential rains and flood tides that accompany a hurricane.

3.2.2 Warnings of impending natural emergencies are issued by the U. S.

Government National Oceanic and Atmospheric Administration (NOAA~)

(National Weather Service) based on various weather surveillance means such as

radar, satellite photographs and meteorological reporting stations.

These warnings provide adequate infomation of

-g the approach of most natural emergency conditions.

Y l

s., nn ;- w. r- - - ~.

~.---.

EMERGENCY PM 20106, PAGE 3 NATUPAL EMERGENCIES

3. 2.3 he warnings issued by NOAA (National Weather Service) are received at the FPL System Operations Power Coordinator's Office on the Weather teletype network.

The information received at the FPL System Operations Power Coordinator's Office is then relayed to the Turkey Point Plant, Units 3 and 4 Control Room through one of the various normal or emergency co n nication channels described in Emergency Procedure

20112, Co n nications Network.

3.3 Authority

Turkey Point Plant Emergency Plans

3.4 Definitions

he following terns, as used by NOAA are used throughout this procedure:

3.4.1 TORNADO WATCH:

Meteorological conditions in the area described as favorable to the formation of tornadoes.

3.4.2 TORNADO WARNING:

his condition is declared once the surveillance means have shown that a tornado has been sighted. W e area for which this warning is issued is usually smaller than that for which a watch is declared.

3.4.3 TROPICAL STORM:

A~ weather disturbance of large size with winds of 39 to 73 uph, rotating in a counterclockwise direction, acconpanied by torrential rains and an area of low barometric pressure.

3.4.4 HURRICANE

Same as a tropical storm, but the winds are over 73 aph and a well defined low barcrnetric pressure center, called the EYE of the storm, is present.

3.4.5 EYE: The center of a hurricane where calm prevails, with winds of ra nore than 20 - 30 nph and little or no rain.

3.4.6 HURRICANE ADVISORY: Wis is 'u) information release put out every six hours, usually at 12 o' clock and 6 o' clock both day and night

(-

whenever a hurricane exists; the advisory is continually updated and this information is iscued in the form of BURRICANE BULLETINS which are issued every 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />, day and night.

3.4.7 HURRICANE WATCH:

This is a comninication from NOAA, issued whenever a hurricane is between 24 and 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> from, and approaching, the U.S. coast and conprises an area approximately 100 miles either side of the expected place where it could come inland.

It also gives the size, maximum winds, direction and speed of travel.

([,;

.-c.,,,,

.c,..7.,.

,,..g

..,...m

,_.,,,....7

8I EMERGENCY PROCEDURE 20106, PAGE 3 NA2 URAL EMERGENCIES 3.4.8 HURRICANE WARNING:

his is a cormunication from NOAA, issued whenever a hurricane is between 12 and 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> from, and approaching, the U. S. coast and conprises an area approximately 50 miles either side of the expected place where the hurricane will strike the coastal areas.

Se size of the area cortprised by the warning will be determined by the area' over which hurricane force winds can be expected. 21s warning also gives the expected time and location where the hurricane will strike the coast, as well as the size, maxinum winds, direction and speed of travel. He warning may also describe the coastal areas where high water, floods or high waves may be expected.

4.0 Precautions

4.1 All unnecessary personnel in the Protected Area and all visitors in the Owner Controlled Area shall be required to leave when a hurricane warning is issued for the area.

Flooding of the low-lying portions of the area, from heavy rains and high tides may make later evacuation inpossible.

4. 2 If a hurricane passes directly over the plant area, do not assume the hurricane has passed when the winds subside and rain stops. m is only means that the EYE of the hurricane is over the area, and in approximately 1 hcur the winds will begin blowing again frcrn the opposite direction as the second half of the hurricane goes over the area.

4.3 When the hurricane is near the area and high winds are occurring, keep all activities outside of the plant buildings to a minimum.

4.4 Do not assume the emergency to be over until the receipt of official word from NOAA through the System Operations Power Coordinator that there is no longer a threat to the area.

5.0 Responsibilities

5.1 It shall be the responsibility of the Site Manager, Plant Manager - Nuclear, Maintenance Superintendent - Nuclear, Operations Superintendent - Nuclear, Technical Department Supervisor, and Instrument and Control Supervisor to conply with the steps outlined in Section 8.0 of this procedure to protect the plant and personnel from the effects of the emergency.

i'

6.0 aeferences

6.1 W rkey Point Plant Emergency Plans 6.2 hrkey Point Plant, Units 1 and 2 Hurricane Plans 6.3 National Oceanic and Atmospheric Administration Information - information on area tornado and hurricane reports 6.4 FSAR, Section 2, and Figures 1.2-3 and 1.2-4 6.5 Bechtel Corp. Drawing No. 5610-SK-C-289 Main Plant Perimeter Flood Wall s~

< ;,; a s m r

.g

e-7.- ~ -

y, y. - -

.w

-O -e 7

~~~r-~-~

.n-

<r-

~

-~

2/4/82 EMERGENCY PROCEDURE 20106, PAGE 4 NATURAL EMERGENCIES 7.0 Records and Notifications:

If the Emergency Plans are initiated as a result of the natural emergency, records and r.otifications shall be as described in other Emergency Procedures.

If the Emergency Plans are not initiated only nomal log entries are required.

8.0 Instructions

l NOTE:

If a hurricane or tornado warning is received, notify the Nuclear Plant Supervisor that an " unusual event" has occurred l.

8.1 When information is received that a Tornado Watch has been issued for the area in which the plant is located:

8.1.1 The Nuclear Plant Supervisor shall notify the Site Manager or Plant Manager - Nuclear (if they are on-site), the Duty Call Supervisor (if the Site Manager or the Plant Manager - Nuclear were not notified),

the Security Shift Supervisor at the Main Entrance Station and plant personnel on his shift.

He shall also infom them that an Unusual Event is in progress.

8.1.2 The Site Manager / Plant Manager - Nuclear / Duty Call Supervisor shall evaluate the infomation, and decide if further action and/or manpower is required.

8.1.3 The Security Shift Supervisor shall ensure that all visitors in the Owner Controlled Area are notified of the Tornado Watch.

s 8.2 When infomation is received that a Tornado Warning has been issued for the area in which the plant is located:

8.2.1 The Nuclear Plant Supervisor shall notify personnel as in 8.1.1 above.

This shall be an Unusual Event unless the tornado strikes the facility (in which case an ALERT would be declared).

8.2.2 The Site Manager / Plant Manager - Nuclear / Duty Call Supervisor shall evaluate the information and decide if further action and/or manpower is required.

/ ~~

8.2.3 The Security Shift Supervisor shall notify all visitors in the Owner V

Controlled Area of the warning and ensure that they leave the property.

8.2.4 The Maintenance Supervisor - Nuclear, if available, or the Nuclear Plant Supervisor and Nuclear Watch Engineer shall conduct a survey of all plant areas and the equipment on them and remove or tie down any loose material or equipment that could be blown away.

8.2.5 The Auxiliary Equipment Operator shall clean the intake trash barrier and start the intake traveling screens.

8.3 When any tornado strikes the facility:

W.?

~

8.3.1 The Nuclear Plant Supervisor shall declare an ALERT and initiate the Emergency Plan.

pm,,,~,-mm,,,v.gy.m-..u,ve m

,m-c w.me m

m ~. -

6/10/82 EMERGENCY PROCEDURE 20106, PAGE 5 NATURAL EMERGENCIES 8.3.2 The Nuclear Plant Supervisor shall notify personnel as in Instruction 8.1.1 (above).

8.3.3 The Site Manager / Plant Manager - Nuclear / Duty Call Supervisor shall evaluate the infomation and decide if further action is required.

8.4 When infomation is received that a Hurricane Watch' has been issued for the area in which the plant is located:

8.4.1 The Nuclear Plant Supervisor shall notify the Site Manager or the Plant Manager Nuclear (i f they are on-site) or the Duty Call Supervisor (if the Site Manager or the Plant Manager - Nuclear were not notified).

8.4.2 If visitors have not yet been required to leave, the Plant Security Supervisor shall order the Security Shift Supervisor to infom all visitors of the Hurricane Watch issued and ensure that they leave.

8.4.3 The Operations Superintendent - Nuclear or Nuclear Plant Supervisor shall verify that the following preparations are made:

1.

Check operation of the NAWAS and LGR equipment, base radio and portable radio equipment.

2.

Test run both A and B emergency diesel generators, top off day and skid fuel tanks and verify that starting air is at 240 psi.

3.

Test run the turbine DC oil pumps.

4 Check fire system and itest run the fire pumpsl.

5.

Test run the intake trash rakes and traveling screens.

8.4.4 The Maintenance Superintendent - Nuclear or his designee shall verify that the following preparations are made:

l

)

1.

Check supply of emergency items and materials such as:

l Wire Wooden wedges Flashlights and Batteries

[.

Lumber Buckets Portable bedding equipment x.. '

Rope Caulking Portable Fans and Air Movers Nails Plastic Film Cloth (pliofilm) 2.

Provide a truck and driver to obtain foodstuffs and other required items.

l

.****1**",",%'n M' #l?'*A* * **T 4"[.

, ~

    • ^***~"W

' "3 V '

? A "*: '? "* * ** ' * *

    • W;**

^:'X*

    • v

" ~ ~ ~

e 6/10/82 EMERGENCY PROCEDURE 20106, PAGE 6 NATURAL EMERGENCIES 3.

Cl ean sumps and sump pump suction strainers on the auxiliary building and electrical cable manholes.

Test run all sump pumps.

4.

Survey the plant site removing trash and debris and securing loose equipnent.

8.4.5 The Operations Superintendent Nuclear shall verify that the following preparations are made:

1.

Inventory supply of laboratory chemicals and reagents and obtain those that are necessary.

2.

Check diesel oil storage tank and turbine lube oil storage tanks.

Diesel oil storage tank should be topped off and turbine lube oil storage tank should be at least half full.

3.

Make arrangements with the diesel oil suppliers for possible emergency deliveries.

4.

Bolt or tie down all hatches on water plant tanks.

8.4.6 The Instrument and Control Supervisor shall check all instrtunents located outdoors to be in weather proof condition, inspect cases, gaskets, etc. and weatherproof those that are not with plastic film and tape.

8.4.7 The Land Management Site Manager shall make arrangements with the Air Force Sea Survival School for removal of their boats and loose gear from the area; and also with any outside contractor working within the plant property to remove, tie down, or otherwise secure his equipment and material to keep it from blowing away.

8.4.8 The Administrative Supervisor shall have all food storage facilities inventoried, a grocery list prepared and the necessary food purchased and properly stored.

Enough food shall be purchased for all operators, maintenance and guard parsonnel staying on site during the storm for several days.

8.5 When information is received that a Hurricane Warning has been issued for the area in which the plant is located:

8.5.1 The l Plant Supervisor - Nuclearl shall notify personnel as in 8.3.1 above.

This shall be classified as an Unusual Event unless there is reason to upgrade the classification to an ALERT.

8.5.2 Tne Plant Security Supervisor will inform the Security Shift Supervisor to close the barriers to all unauthorized traffic.

8.5.3 The Operations Superintendent - Nuclear or Nuclear Plant Supervisor shall verify that the following preparations are made:

1.

Make arrangements for sufficient operating personnel to be at the C.

plant during the hurricane in order to provide the necessary G

coverage for several days during which the plant may be inaccessible.

p3,,,-

~

nw

p. w

EMERGENCY PROCEDURE 20106, PAGE 7 3/26/81 NATURAL ENERGENCIES 2.

Fill condensate tanks, primary water tanks and refueling water storage tanks.

3.

When hurricane is less than 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> from the plant have portable bedding equipment brought to the control rom and/or cable spreading room and other suitable locations.

4.

Open and tag outdoor 480V receptacle circuit breakers.

(See attachea breaker list, Appendix A).

Issue clearance to Nuclear Plant Supervisor on all breakers opened.

5.

As the hurricane approaches the site, and high winds begin, stop the vent fans listed below:

NOIE:

Fans may be operated on a selected basis as operating conditions dictate.

Spent fuel pit ventilation fan New fuel storage rom vent fan Spent fuel pit heat exchanger room vent fan Containment purge supply and exhaust fans Auxiliary building supply vent fans Containment penetration cooling fans if not required 4160V Switchgear and 480V L. C. roons vent fans Diesel generator room vent fans 6.

Shutdown Amertap Systems, open and tag power supply breakers to

.V all punps and valves, clearance to the Nuclear Plant Supervisor.

8.5.4 The Maintenance Superintendent Naclear shall verify that the following preparations are made:

1.

Close the following outside doors and roof hatches and inflate door seals where applicable.

(1) Clatside Doors:

Cable Spreading Room to roof (through CRDM room)

New Fuel Storage Ibons Spent Fuel Pits Conp. Cooling Water Surge Tank Room Door from Auxiliary Building to Ttarbine Area 480V L.C. Iboms 4160V Switchgear Rooms Doors to Holdup Tank enclosures Emergency Diesel Room doors Turbine and Auxiliary Building Chemical Storage Room Door fra Aux. Building to No. 4 Cong. Cool Water Equip.

Area Elevator vestibules Containment Purge Supply Fan Room Inlet to No. 3 Charging Puup Room from Boric Acid Tank Area

,(..;

Intake Chlorinator Equipment House Reactor Control Rod RIuipnent Boons (3B and 4B MCC Iboms) s-Electrical Penetration Rooms and Enclosures Generator Exciter Switchgear Roons Radwaste Building Doors (East, West, and Icading Ranp) l 1

-( p,.

w.m,= 3 ; r m.s m ~ y ~ >

wy-cye

.p.
- c 3 ; m -v, ~;<

, ~7 g wp = w e ~-

~-

s

~

~

3/26/81 EMERGENCY PROCEDURE 20106, PAGE 8 NATURAL EMERGENCIES (2) Ibof hatches:

RER punp renoval hatches Evaporator Condensate Demineralizers Monitor Tanks Radwaste Building 2.

Install stoplogs on plant flood protection wall as follows:

(Ref. to Dwg. No. 5610-6K-C-289)

By the Unit 3 4160V Switchgear Room entrance By the Diesel Oil Storage Tank Dike Area By the Unit 3 and Unit 4 Main Transformers By the Unit 4 Steam Generator k%ed Punp Room By the Unit 4 Blowdown Tank On the entrance to the Unit 3 Conp. Cool Water Pung Area On the entrance to the Unit 4 Conp. Cool Water Punp Area By the Unit 3 and Unit 4 New Fuel Storage Area By the Unit 3 and Unit 4 Inbe Oil Reservoir On the entrance to the Unit 3 and Unit 4 Condenser Pits On the entrance to the Unit 3 and Unit 4 Spent Fuel Pit Heat Exchanger Iboms Cn the entrance to the Aux. Building Chemical Storage Area 3.

Tie down, remove, or otherwise secure all loose equignent, such as ladders, fire extinguishers and hose reels, waste containers, life rings, etc.

4.

Store all chemical drums in the chemice.1 warehouse, and oil drums in the oil house-and/or chemical warehouse.

i l

S.

Verify that the gas cylinders in both gas cylinder storage houses l

are properly secured.

6.

Remove vortex eliminators frm the intake area, and clean the trash pit.

7.

Dog the intakc area gantry crane, the cask crane and the turbine deck gantry crane.

8.

Install life lines between inportant operating areas of the plant in case personnel nust be sent to these areas during high winds.

9.

Provide tarpaulins and ropes at various locations throughout the auxiliary building; also have on hand in the control center and l

cable spreading rom an anple supply of plastic film (pliofilm).

l

10. Ensure that mechanics and electricians will be available at the plant during the emergency.
11. Provide portable dewatering punps at Condensate Pung Areas, Units 3 and 4.

(n t

i u

4

m. m_'g'.,.,.,;..

m.,_._._.,_

i 9,

'c-,

^

r 3g

,.3 3/26/81 EMERGENCY PROCEDURE 2)l06, PAGE 9 NAIUPE EMERGENCIES

12. Close doors and vent openings on the elevator machinery room.
13. Wire shut all doors on outdoor MCC's, with insulated wire.
14. Take spare sung punps to the Auxiliary Building.
15. Tie down intake trash rakes and hoists in such a manner that they are secure, yet readily available if needed.
16. When the vent fans listed in 8.4.3.5 are stopped, the following air intake, exhaust, or vent openings should be closed off.

Verify that the danpers of those openings equipped with danpers are locked in the closed position.

Install protective covers where required, as follows:

Spent Fuel Pit Inlet Air Vents New Fuel Storage Room Fan Inlet Vent Spent Fuel Pit Heat Exchanger Room Fan Inlet Vent Spent Fuel Pit Heat Exchanger Roan Exhaust Vent Containment Purge Supply Fan Air Intake

[

Auxiliary Building Supply Fans Air Intake Vent Control Room HVAC Outside Air Intakes Control Ibom HVAC Post MBA Emergency Fan CAltside Air Intake 4160V Switchgear and 480V L.C. Rooms Exhaust Fan Vents 8.5.5 2e Cperations Superintendent melear shall verify that the

(

following preparations are made:

1.

Bolt or otherwise secure the hatches on the chemical feed tanks.

8.5.6 2e Instrument and Control Supervisor shall ensure that I and C Specialists will be available at the plant during the emergency and shall verify that the following preparations are made:

1.

Protect exposed vital instrumentation from the high winds and possible flying debris.

8.5.7 he Site Manager shall verify that required additional personnel have been notified and are available.

I 8.6 When information is received of the approach of a hurricane with winds up to design basis (215 aph) levels, the Nuclear Plant Supervisor shall declare an Alert and activate Emergency Procedure 20101, Duties of Emergency Coordinator, and Emergency Procedure 2)l03, Classification of Emergencies.

Provisions of Step 8.5 shall also be followed.

t 8.7 When information is received of the approach of a hurricane with winds

[

greater than design basis (225 aph) levels, the N.1 clear Plant Supervisor shall declare a Site Area Emergency and activate Emergency Procedure 20101, Duties of Emergency Coordinator, and Emergency Procedure

20103, Classification of Emergencies.

Provisions of Step 8.5 shall also be l

followed.

l h3 o:.

I

[

h 7.g.

7

,,,p:,,,,

.c

._7,,.

y J

n-t

,?-

EMERGENCY PROCEDURE 20106, PAGE 10 3/26/81 NMURAL EFJGENCIES 8.8 When information is received that lower high water levels (50 year flood or low water) is anticipated in the area of the plant (but a Hurricane Watch is not in effect):

8.8.1 The Nuclear Plant Supervisor shall classify it as an Unusual Event and activate Emergency Procedure

20101, Duties of Emergency Coordinator, and Emergency Procedure
20103, Classification of Emergencies.
8. 8.1 If high water is anticipated but not high wind, those provisions of Step 8.4 shall be carried out which are directed toward concern for high water.

t 8.9 When flood, low water, hurricane surge, or other abnormal water conditions cause the storm drainage system to be exceeded, the Nuclear Plant Supervisor shall declare an Alert, and activate Emergency Procedure 20101, Duties of Emergency Coordinator, and Emergency Procedure 20103, Classification of Emergencies.

8.10 When flocd, low water, hurricane surge, or other abnormal water conditions cause vital equipnent to fail, the Nuclear Plant Supervisor shall declare a Site Area Emergency and activate Emergency Procedure 20101, Duties of Emergency Coordinator, and Emergency Procedure 20103, Classification of Emergencies.

8.11 When any earthquake has occurred as indicated on the seismograph, the M.1 clear Plant Supervisor shall classify this as an Unusual Event and activate Emergency Procedure 20103, Classification of Emergencies.

8.12 If any earthquake occurs greater than the Operating Basis Earthquake, the Nuclear Plan Supervisor shall declare an Alert and activate Emergency l

Procedure

20101, Duties of Emergency Coordinator and Emergency Procedure 20103, Classification of Emergencies.

l 8.13 When an earthquake occuru greater than the Safe Shutdown Earthquake,the Nuclear Plant Supervisor shall declare a Site Area Emergency and activate Emergency Procedure 20101, Duties of Emergency Coordinator, and Emergency Procedure 20103, Classification of Emergencies.

/

8.14 Stop all non-essential handling of radioactive materials and avoid releases l(

of radioactive water to the environment during the duration of the emergency.

P 8.15 In the case of weather emergencies, wait until official word is received frun NOAA through the System Operations Power Coordinator, that the causes of the emergency are over and that the threat to the area is over before terminating the emergency conditions.

i F

h,p@

\\

--*.,ee rp.

w

.g

, e e.g - g-

--r p,

w.,--

g y y.-,

+=s, g

-pe

-e w. eye r -

g,*.e-g

EMERGENCY PROCEDURE 20106, PAGE 11 NA'IURAL EMERGENCIES APPENDIX A 480 VOLT RECEPTACLE LIST BREAKER NO.

RECEPTACLE NO./IDCATION 30653 17 and 17a, Unit 3 Containment 30661 5, West End, Aux. Building E/W Passageway 30674 6, 6A and 6B East End and Exterior East Wall of Aux.

Building (See Note 1) 30736 7, North End, Aux. Building N/S Passageway 30905 11 and 12, North End of Intake Area 30760 8, Unit 3 Cask Wash Area (See Note 2) 40653 17 and 17a, Unit 4 Containment 40903 15 and 16, Intake Area (at Traveling Screens 0870 9, South End of Aux. Building N/S Passageway 0871 10, Unit 4 Cask Wash Area (See Note 2) 10 23 13, Water Treatment Plant Area B1605 01, Radwaste Control Area, West Wall B1704 02, Radwaste N/S Passageway, North End B202 03, Radwaste N/S Passageway, South End l

Radwaste Building, outside East Wall at ~ door to Control Area, welding receptacle B2067 Trash Coupactor Ibom (See Note 3), Welding Receptacle Panel 3P14, Bkr 1

'IWo Receptacles outside North Wall and two outside East Wall of No. 3 4160 Switchgear Roca l

Panel 3P14, Bkr 2 One Receptacle at SE Corner No. 3 Aux. Trans.

Panel 3P14, Bkr 3 One Receptacle at No. 3 Bowser Filter One Receptacle at West of 3A MSRH One Receptacle at SW Corner of Cond. Retubing Pit, Ground Ievel (See Note 4)

Panel 3P14, Bkr 4 One Receptacle in Aux. Feedwater Pung Area One Receptacle East of 3D MSRH Panel 3P14, Bkr 5 One Receptacle, hrbine Deck, West Side between Units 3 and 4 One Receptacle under South End of Steam Platform Panel 3P14, Bkr 6 One Receptacle on Mezz. IAvel at Panel 3P14 (4

One Receptacle at NE Corner of Turbine Deck Panel 3P14, Bkr 7 One Receptacle at NW Corner of W rbine Deck Panel 4P14, Bkr 1 One Receptacle at East Wall No. 4 4160 Boom Panel 4P14, Bkr 2 One Receptacle at SE Corner No. 4 Aux. Transformer l

Panel 4P14, Bkr 3 One Receptacle at South Side of Cond. Retubing Pit, Ground Iavel (See Note 4)

One Receptacle East of Bowser Filter One Receptacle West of 4A MSRH Panel 4P14, Bkr 4 One Receptacle East of 4D MSRH One Receptacle East of No. 4 S/G Feedwater Punp Boom Panel 4P14, Bkr 5 One Receptacle at SW Corner of Wrbine Dedt One Receptacle under South edge of Steam Platform p

Panel 4P14, Bkr 6 One Receptacle on Mezz. I4 vel at Panel 4P14

- Q~

One Receptacle on Wrbine Deck, South of Control Room Door t

i i

y ---

,en,

~,,,

p ;

,.m

,,,3

.-,,y,-~~,.'

81 EMERGENCY PIOCEDURE 20106, PAGE 12 NATURAL EMERGENCIES APPENDIX A (cont'd}

Apprentice Training Building - Incal breakers on seven welding receptacles on exterior North wall.

NOTE 1:

Also provides power to B.A.E. tenporary punps.

NOTE 2:

Power supply to Emergency Spent Fuel Pit Cooling Water Punps NOTE 3:

Power supply to trash conpactors NOTE 4:

Power supply to L.O. Reservoir Oil Renovators (Delaval) er f

,L h+

. ;s

==

a.:,

s..

t a

S' 4,,--

,<m.---r--

,.m,~,.

,y,-

3 gm.-+ - fyn _,--

(

FLORIDA POWER AND LIGHT COMPANY N

TURXEY POINT UNITS 3 AND 4 EMERGENCY PROCEDURE 20201 JUNE 3, 1982

1.0 Title

MAINTAINING EMERGENCY PREPAREDNESS - RADIOLOGICAL EMERGENCY PLAN TRAINING 2.0 Anproval and List of Effective Pages:

2.1 Approvals

\\

Change dated 6/3/82 Reviewed by PNSC June 3, 1982 Approved by

4. Plant Mgr-Nuclear, M7 19 82 Approved by Vice President of L/

[

Nuclear Energy NS 19P2 2.2 List of Effective Pages:

Page Date Pace Date Page Date 1

6/3/82 3

3/26/81 5

6/3/82 2

3/26/81 4

3/26/81 E

'3.0 Scoce:

3.1 Purpose

This procedure provides requirements for periodic training of individuals, onsite, who may have some response upon initiation of the Turkey Point Plant Radiological Emergency Plan.

3.2 Discussion

In order to maintain emergency preparedness, persoanel working at the Turkey Point Plant must be familiar with certain preplanned actions in the gpt Emergency Plan and its implementing procedures.

Any changes in required actions or response due to revision of the Plan or procedures must be presented to appropriate personnel on a periodic basis.

3.3 Authority

Turkey Point Plant Radiological Emergency Plan

3.4 Definition

Throughout this procedure, the terms Emergency Plan and Plan will be used to g:7 mean Turkey Point Radiological Emergency Plan.

Eli-1 1

t { "I[.. '. i., ',.

Y'

~~

~

f -k ? -

3/26/81 EMERGENCY PROCEDURE l0:01, PAGE 2 MAINIAINING EVERGENCY PREPAREDNESS RADIOILGICAL EMIRGENCY PIAN TRAINING 4,

4.0 Precautions 4.1 21s procedure does not cover requirements for periodic training of the FPL Off-Site Emergency Organization.

5.0 Responsibilities

5.1 he Plant Manager - Nuclear has the overall responsibility for Emergency Plan Training.

5.I ne Training Supervisor is responsible for ensuring all Emergency Plan C

Training is conducted in accordance with the references listed herein.

c 5.3 he primary team leader of each emergency team is responsible for the developnent and inplementation of his team's training and retraining program.

He may assign conpetent individuals to assist him in acconplishing this task.

5.4 he Operations Superintendent - Nuclear is responsible for the development and inplementation of the Emergency Coordinator training and retraining program.

He may assign conpetent individuals to assist him in accomplishing this task.

5.5 he Training Supervisor is responsible for development and inplementation of Emergency Plan Training of all candidates for reactor operator or senior p

reactor operator licenses.

wr 5.6 he Health Physics Supervisor shall provide for training all individuals requiring unescorted access ensite describing the action to be taken by an individual discovering an emergency condition, the location of assembly areas, the identification of emergency alarns, and the action to be taken on hearing those alarms.

6.0 Beferences 6.1 Turkey Point Plant Radiological Emergency Plan 6.2 10 CFR 50.47

?(,

6.3 10 CFR 50 Appendix E 6.4 NUREG 0654, Revision 1 7.0 Records and Notifications:

Records documenting the Emergency Plan Training received by individuals are quality assurance records and, tnerefore, shall be retained in accordance with Administrative Procedure 0190.14, Document Control and Quality Assurance Records.

f~-

Q*,U g - - -.

--v-

,y.w

3/26/81 EMIRGENCY PROCEDURE ;0;01, PAGE 3 MAINIAINING EMIRGENCY PREPAREDNESS RADICIDGICAL EMIRGENCY PIAN TRAINING

8.0 Instructions

8.1 Emergency Coordinator Training All Nuclear Plant Supervisors, Nuclear Watch Engineers, Reactor Control Operators (who are holders of Senior Reactor Operator licenses) shall receive training in categories provided in this section, annually:

8.1.1 Interpretation of plant and field data and how it relates to emergencies and their classification (i.e. emergency action level determination).

8.1. ; Prorpt and effective notification rethods, including the types of comnunication system 8.1.3 Method of activating the Florida Power and Light Cortpany Emergency Organization.

8.1.4 The rethods used for estimating radiation doses.

8.2 Cther qoerational Assistance Other personnel who may be required during an emergency shall receive training in the following areas on an annual basis:

8. ;.1 Emergency Plan familiarization.

8. 2. 2 Emergency Plan inplementing procedures familiarization.

8. :.3 Con::unications and notification methods.
8. 2. 4 Accident assessment and corrective action.
8..5 Specific Emergency Team Training (for individuals assigned to emergency teams) 8.3 Shift Technical Advisor

, ~ '

All Shift W ehnical Advisors shall receive the following annual training:

8.3.1 Emergency Plan familiarization.

8.3. ; Emergency inplementing procedures familiarization.

8.3.3 hchnical Specifications (in-depth understanding) 8.3.4 Specialized training in power plant and reactor specific core operating characteristics (normal and abnormal).

l 8.3.5 Familiarization with other related Plant programs,

plans, and procedures with enphasis on accident assessment techniques.

.p.

l

.- ~~~

7

..,.7... -_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

I

.o 3/26/81 EMERGENCY PROCEDURE ;0 201, PAGE 4 MAIhTAINING EMERGENCY PREPAREDNESO RADIOwGICAL EMERGENCY PLAN. TRAINING 8.4 Erergency ham 8.4.1 Emergency Team Leaders shall have successfully conpleted Group A training in radiation protection conducted by the Health Physics group.

Successful cortpletion of this training is acknowledged by the issuance of a " Red Badge" identification card.

All assigned leaders shall participate in an annual training exercise designed to have them and their teams respond to sinulated situations.

'Ihe primary team leader is responsible for scheduling, conducting, and documenting such exercises.

8.4.2 Team members shall have successfully conpleted the Group A courses and hold a " Red Badge" identification card.

8.4.3 Specific emergency team training shall be conducted by the u;;;r.ed team leader or his qualified designee familiarizing team members with their responsibilities described in the Emergency Plan and its inplementing procedures, comnunications and coordination with other emergency teams and the following team-specific topics:

1.

Emergency Radiation 'Ibam (1) Use of air sanpling equipment.

( 2) Performance of contamination surveys.

(3) Determination of air activity.

(4) Datermination of radiation levels.

(5) Recordkeeping methods.

(6) In-depth knowledge of personnel and field monitoring / analyzing techniques.

(7) Responsibilities of the Emergency Radiation Team.

l 2.

Security Team (1) Personnel accountability procedures.

( 2) Site ingress and egress control procedures.

l (3) Deployment of Security Personnel.

l 3.

First Aid / Decontamination Team (1) Description, storage location, and application of suppliers and eqaignent.

e.

( 2) Sequential steps for the assessment and treataent of N.

personnel injury and contamination levels.

1 7~- -.

n.,.

r

6/3/82 EMERGENCY PR'0CEDURE 20201, PAGE 5 MAINTAINING EMERGENCY PREPAREDNESS RADIOLOGICAL EMERGENCY PLAN TRAINING (3) Allowable and advisable radiation enviro'nments and exposures.

(4) Personnel decontamination procedures.

(5) Procedures for the evacuation of contaminated persons to off-site medical facilities.

(6) lAll team members will satisfactorily complete the American National Red Cross Multi-Media First Aid Course.

Each team member will receive yearly refresher trainingl.

4.

Fire Team t

Fire Team training is covered by the Fire Protecticn Program, Administrative Procedure 15500.