_ _ _ _ _

i i

I Q$

For 244 g

y f.T' JJ4T A. G t 0 8 -

Carolina Power & Light Company Q

a s. ~ :: m.

-e-

-w -+ ~

$ $EM

11. B. ROBINSON STEAM ELECTRIC PLANT cornpany correspondence POST OFFICE BOX 790 liARTSVILLE, SOUTil CAROLINA 29550 APR'A 71982 Robinson File No.:

13510C Serial: RSEP/82-811 Mr. James P. O'Reilly Regional Administrator W

U. S. Nuclear Regulatory Commission k

Region II m

y'O i

101 Marietta Street, Suite 3100 t

Atlanta, Georgia 30303 co yo

%y

11. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 2

c, m DOCKETNO.50-261/p C

D:@

LICENSE NO. DPR-23 90 N

PROMPT NOTIFICATION - INSERVICE INSPECTION I

OF STEAM GENERATOR TUBES E-

Dear Mr. O'Reilly:

In accordance with Section 6.9.2.a. (3) of the Technical Specifications for the !!. B. Robinson Steam Electric Plant, Unit 2, the following event is reported.

During the current refueling outage, a 100% eddy current inspection of all three (3) steam generators was performed. Upon completion of the inspection on April 26, 1982, "B" and "C" steam generators had pluggable indications of 4.4% and 1.5%

respectively. Therefore, "B" and "C" steam generators are classified as sampling category C-3, which is reportable pursuant to Technical Specification 4.2.5.3.3.

A description of the inspection and planned corrective actions will be submitted in the licensee event report.

Mr. C. Julian, NRC Region II and Mr. B. J. Furr, Vice President - Nuclear Operations were notified of this event on April 27, 1982.

Very truly yours, R. B. Starkey, J.

General Manager

11. B. Robinson S.E. Plant IITC :Ja C

oyYs #

c IU" 7 8209100130 820427 PDR ADOCK 05000261 S

PDR

..