Reactor Containment Bldg Integrated Leakage Rate Test Rept for 1993 for Beaver Valley Power Station Unit 2
ML20063H749
Person / Time
Site: Beaver Valley
Issue date: 01/24/1994
From: Fenner S, Patterson J, Sieber J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9402220178
Download: ML20063H749 (64)


Text

v 9

s

_Q Beaver Valley Power Station l

Shippingport, PA 15077-0004 l

JOi!N D SIEBEF1 (412) 393-5255 Pres " ' "

*(#' '# "

  • In"N'Nuclea, o cer February 3, 1994 l

i Nuclear Power Division l

U.

S. Nuclear Regulatory Commission l

Attn:

Document Control Desk Washington, DC 20555 l

Subject:

Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Reactor Containment Building Integrated Leakage Rate Test l

l l

Enclosed is the 1993 Beaver Valley Unit No. 2 Reactor Containment Building Integrated Leakage Rate Test Report submitted in accordance with Appendix J of 10 CFR Part 50.

The report provides a summary'of the Integrated Leakage Rate Test conducted at BVPS Unit No. 2 during l

l the fourth refueling outage.

Also submitted with this report is a summary of results for all local leakage rate tests performed since the previous Integrated Leakage Rate Test.

Sincerely, l

rl

!)

J.

D.

Sieber Attachment cc:

Mr.

L.

W.

Rossbach, Sr. Resident Inspector Mr. T.

T. Martin, NRC Region I Administrator i

Mr.

G.

E.

Edison, Project Manager i

ascmc UTlUTYof 181 La. 0 unn h

9402220178 94o124 tr DR ADOCK 05000412 p

i PDR g

kl i

A s

e s

INIEPATID IB0GGE RATE TEST DUQUESNE IlGff C34PANY BEAVER VALIEl POWER SIATION UNIT NO. 2 NOVEMBER 1993 C

s.

. Patte m m ~

Date:

IaIl Ci Prepared By:

~ tem Ergineer Reviewed By:

4t41 Date:

/~ /7" 9 G.L//Shildt Supervisor, System Engineering R r kn&

ipqu D,te:

R. T. 2% owski Director, System Ergineerirg MW/

Date: /[8d M a

a D. G. McIain Manager, Maintenance Engineering and Assessment Department Q

Approved By:

th Date: /~2 -

ger, Maintenance Programs Unit

L l

7ABLE OF CCtfrENTS l

]

I section Title Engs TABLE OF CONTENTS 11 LIsr OF ATIAO MENTS 111 l

REFERENCES iv I

1 PURPOSE 1-1 1

2 SllNARY j

2.1 7YPE A IIRT 2.1-1 2.1.1.

Test Sunnary 2.1-1 2.2 IOCAL LEAKAGE RATE TESTS (TYPES B & C) 2.2-1 1

3 INrEERATED LEAKAGE RATE TEST l

l 3.1 EDITED LOG OF EVENTS 3.1-l '

j 3.2 GENERAL TEST DESCRIPTION 3.2-1 l

l 3.2.1 Prerequisites 3.2-1 1

l 3.2.2 Equipment ard Instnnnentation '

3.2 '

l 3.2.3 Data Acquisition' 3.2 3.2.4 Data Resolution System 3.2-2 3.3 TEST RESUIlFS 3.3-1 3.3.1 Presentation of 7bst Results

-3.3-1 3.3.2 59.4 PSIA IIRT Results-3.3-2 3.3.2.1 IIRT Results - Mass Point Analysis 3.3-2 3.3.2.2 Supplemental 7bst Results 3.3-3 3.3.2.3 Isakage Penalties Achi to IIRT Isakage

.3.3 l 3.3.2.4 As Found Containment Condition - LIRr Inprovements 3.3-6 3.3.3 Conclusion

_ 3. 3 4 IOCAL LEAKAGE RATE TESTS (7YPES B AND C) 4-1 11 l

i e

i i

LIST OF ATIAGEDTIS i

i I

A1TAOME27f TITLE i

3.2A Instrumentation List 1

3.2B Instrumentation Selection Guide 3.3A IIRT Puheul Input Variables 3.3B IIRP Absolute Test Method - Mass Point Analysis

'Ibst Results 3.3C Containment Air Mass vs. Time I

3.3D Isakage Rate and UCL vs. Time, Mass

' Point Analysis 3.3E Superimposed Isakage Verification Test RuhM_

Input Variables 1

3.3F Superhrveui Isakage Verification Test, Absolute Test Method - Mass Point Analysis 4.1A

'Ihird Refueling Iccal Teakage Rate 'Ibst Data 4.1B

'Ihird Refueling Iccal Isakage Rate Repairs 4.1C Fourth Refueling Local Icakage Rate Test Data 4.1D Fourth Refueliry Iocal Leakage Rate Repairs 4.1E

'Ihird and Fourth Fuel Cycle local Icakage Rate Data' iii

l t

t I

I REFERD7CES i

l l

1.

10CFR50, Apperdix J,

Primary Reactor Containment Isakage Testing For '

i Water-Cooled Power Reactors, January 1, 1993.-

l 2.

2BVP 1.47.2, Containment Type A Imak Test, Beaver Valley Power Station l

Unit No. 2, Issue 2, Revision 1, September 13, 1993 l

3.

ANSI N45.4, American National Standard, Isakage

-Rate Testing'of Containment Structures for Nuclear Reactors, March 16, 1972.:

4.

ANSI /ANS-56.8, Containment System Isakage Testing Requirements, l

January 20, 1987.

i l

1 t

i l

l l

l l

iv 1

m

.., - ~ -

~

g

I I

i l

SECTION 1 PURPOSE I

The purpose of this 4.wi. is to present a description ard analysis of the November 1993 Type A Containment Integrated Isakage Rate Test (IIRP), ard a summary of Type B ard C Iocal Isakage Rate Tests (LIRF's) performed since the last periodic IIRT (November 1990) at Duquesne Light Ctmpany's Beaver Valley Power Station Unit Ib. 2 (BVPS 2).

Stone & Webster Engineering Cw.

ation (SWEC) provided test engineering consultation services to Duquesne Light Ocm1pany during the performance of the 1993 IIRP.

This report is subnitted as required by 10CFR50, Appendix J, Paragraph V.B.

l 1

r L

1 l

i 1-1 l

I

6 l

SECTION 2 SLMMARY 2.1 TYPE A IIRT 2.1.1 Test Summary l

Upon completion of all-IIRT p=aalaisites and initial conditions, containment pressurization started at 2215 hours0.0256 days <br />0.615 hours <br />0.00366 weeks <br />8.428075e-4 months <br /> on November 7,1993 at a fairly constant pressurization rate of 3.0 psi per hour.

%e -em m were secured at 1357 hours0.0157 days <br />0.377 hours <br />0.00224 weeks <br />5.163385e-4 months <br /> on November 8, 1993 with_a peak instantaneous pressure of 61.1759 PSIA.

At 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on November 8,

1993, the t=mycaature stabilization criteria

(<0.5

'R over last two hours) was satisfied, however, ocastainment tenperature I

was still trending downward indicating t e ature was not stable. S e mass trend, which was being influenced by tenperature, was also trending downward.

Penetration area leakage investigations identified no significant leakage.

At 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on November 9,1993, the IIRP was' started based on the improved stability of containment tenperature.

Initial' mama trends indicated an acceptable leakage rate of approximately 9.5 lbn/hr.

1 The IIRP was empleted at 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on November 10, 1993 with a Mass Point-Upper Confidence Ievel of 0.04011 %/ day (see Section 3.3, Test Results). mis leakage rate is below the 0.75 Ia Acceptance Criteria of 0.075 %/ day.

'Ihe Super 4W Isakage Verification Test was started 'at 1900 hours0.022 days <br />0.528 hours <br />0.00314 weeks <br />7.2295e-4 months <br /> on November 10, 1993 when the stability _of all the containment parameter trends had recovered from the imposed leakage rate perturbation.

.% e Superi W i

l Icakage Verification Test was summfully-ompleted at 2300 hours0.0266 days <br />0.639 hours <br />0.0038 weeks <br />8.7515e-4 months <br /> on November 10,1993 (See Section 3.3, Test Results).

j After review of all IIRT test data, containment des assurization started at l

0117 hours0.00135 days <br />0.0325 hours <br />1.934524e-4 weeks <br />4.45185e-5 months <br /> and was completed at 0934 hours0.0108 days <br />0.259 hours <br />0.00154 weeks <br />3.55387e-4 months <br /> on November 11, 1993.

I 2.1-1 l'

l

1 2.2 IOCAL LEAKAGE RATE TESTS (TYPES B AND C)

'Ihe Iccal Isakage Rate Tests (LIRr's) of the containment isolation valves and other containment pe.reuations were conducted as described in the Beaver Valley.

Power Station Unit No. 2 surveillance test p uc=dares for Type B and C tests.

In accordance with Appendix J to 10CFRSO, Parrug@i V.B, data for the local leakage Rate 'Ibsts are sumarized in Section 4 of this inpu L.

I a

t b

l 1

l 1

2.2-1

s l

l SECTION 3 INTIERATED IEAKAGE RATE TEST 3.1 IDITED IDG OF EVDfrS

'Ihis log was edited from information contained in the IIRT Test Ing.

November 7. 1993 l

1955 Prerequisites and Initial Conditions for IIRT cmpleted.

2025 Containment Purge Supply Isolation Valve [2HVR*}OD25B] will not open from the Control Room to allow IIRT pressurization to cemence.

Electrical. Maintenance is notified of problem.

2130 Containment Purge Supply Isolation Valve

[2HVR*}OD25B] opened electrically by resettiry the line starter. Decision was later made to leave [2HVR*}OD25B] open during the duration of the IIRT and rely on

[2HVR* LOD 25A] to isolate the penetration.

[21NR*)OD25B] was repaired l

followiry completion of the IIRP per previously written MRR 24637 (See

'.1D for Penetration No. 91).

2215 Commenced IIRP pressurization.

November 8, 1993 0855 Containment pressure at approximately 45.0 psia. Campleted walkdown of all penetration areas with the following deficiencies noted:

Slight amount of water leaking from Recirculation Spray Pump

[2RSS*P21A] Seal Area (Approximately 2 drops per minute).

Slight amount of water leaking from Recirculation Spray Pump

[2RSS*P21D] Seal Area (unmeasurable amount).

Slight amount of Air Leaking From Recirculation Spray System Demin Water Fill Header Vent [2RSS*101].

1357 Secured containment pressurization with a peak instantaneous pressure of 61.1759 psia.

1400 Commenced IIRT stabilization period.

1702 Completed walkdown of all penetration areas with no new significant leakage noted.

1800 Temperature stabilization criteria satisfied

(<0.5

  • R over last two hours), however, containment temperature is still trending downward.

Will wait until containment temperature stabilizes before IIRT is started.

3.1-1

1 November 9, 1993 0030 Completed walkdown of all penetration areas with no significant leakage noted.

0807 Quantified leakage frun Recirculation Spray System Demin Water Fill Header Vent (2RSS*101] to be approximately 0.45 SCF/M (Vent Valve 1

2RSS*101 was the vent path for ten upstream Recirc Spray System Valves, associated with all four Recirc Spray Punps). No measurable leakage-detected frcan any of the four Recirculation Spray Punp Seals.

0845 Containment temperature is still trending down, i

l I

1622 Refueling canal is filled with water, just above the fuel transfer tube, to allow for leakage investigation. No leakage is de* W.

l 1745 Containment te::perature appears to bc' stable. Decision made to start the IIRT at 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br />.

j 1800 Declared start of IIRP.

i November 10, 1993

.l l

0030 From the data collected, it has been determined that a short duration test using the Total Time Analysis will not be possible, therefore, a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> IIRT will be perfonned using the Mass Point Analysis method.

Mass trend is acceptable at approximately 9.5 lbn/hr. Mass Point Upper Confidence IcVel of 0.064 percent / day.

1400 Containment Mass Point Isak Rate is 0.042 percent / day with a Mass Point Upper Cbnfidence Isvel of 0.043 percent / day.

1800 Ccrmleted IIRP with a

Mass Point Upper Confidence Invel of 0.010 percent / day.

1809 Established a 4.9 SCP/M leakage flow for the Super 4W ed leakage Verification Test.

1900 Cumanced the Superinv=1 Isakage Verification Test.

2300 Completed the Superinposed Leakage Verificaticn 'Ibst with acceptable data obtained.

I November 11, 1993 i

0117 Commenced containment depressurization.

0934 Completed containment depressurization.

3.1-2

~

3.2 GDIERAL TEST DESCRunON l

3.2.1 Prerequisites l

In accordance with Beaver Valley Power Station Unit 2 IIRT Test Procedure l

2BVT 1.47.2, the following is a listirq of the pertinent sucquisites completed and du-nted prior to containment pressurization:

a.

All Type B and C Iccal I.eakage Rate 'Ibsting ocmpleted.

f b.

All test instrumentation calibrated or functionally verified'within 6 months of IIRT.

c.

All penetration valve aliwamuis ocupleted.

d.

All IIRT cmputer software used for. data acquisition, and data analysis, tested and operational.

^

e.

h W ary air wipt:ssors and auxiliary equignent checked out and available for pressurization.

f.

All equi % P.

that could be damaged by test pressure, removed or protected, g.

Portable pressure containing equipment removed from containment.

f i

h.

Depressurized and vented pressure vessels located inside containment.

i 1.

Completed structural integrity inspection of containment.

1 3.2.2 Equipment and Instrumentation l

Pressurization of the containment was achieved by the utilization of a temporary system consisting of seven diesel driven oil free air mip e rs, a water cooled aftercooler, and a refrigerant air dryer. %e system included adequate instrumentation and valving to maintain proper monitoring arx1 control of the ccupressed air quality throughout the pressurization sequence. %e total capacity of the pressurization system was 9000 SG M.

Air was supplied to containment through the Containment Purge System.

We various containment parameters required to calculate containment leakage were ronitored usirq instrumentation which consisted of 18 resistance l

temperature detectors, 5 dewpoint detectors, and 2 absolute pressure quartz manometers.

Pertinent data for the test instrumentation is listed in.2A.

A test panel consisting of a rotameter, pressure gauge, and a thermometer was used to perform the SuperiW I.eakage Verification Test.

)

3.2-1 w

er w T*--'f

3.2.3 Data Acquisition System me data acquisition system used for IIRT was a comp 1ter controlled logging system which provided instantaneous raw sensor data.

For the

IIRT, the Data Acquisition System monitored the following instrumentation:

Type No. of Sensors

'1bmperature Detectors 18 Dewpoint Sensors 5

Quartz Manmeter 2

Instantaneous readings for eadi sensor were collected and printed at 15 minute intervals.

Input to the data analysis program was based on these collections.

Each data set was time stanped.

3.2.4 Data Resolution System he recorded data was inputted to Stone & Webster Engineering Cu putation's computer et wt am for data reduction and leakage rate calculations. S e Mass Point Analysis Method was used to deter.mine the containment leakage rate.

Absolute Method of Mass Point Analysis he Absolute K4 thod of Mass Point Analysis consists of calculatirq the air mass within the containment structure, over the test period, using pressure, temperature, and dapoint data obtained during the IIRP. 20 air mass is computed usirg the ideal gas law as follows:

144V(P-Pv)

{

M=

nr Where:

M = air mass, lhn P = total pressure, psia PV = average vapor pressure, psia R = 53.35 ft-lhn/lhu 'R (for air)

T = average containment temperature, 'R V = containment free volume, 1,716,633 cu. ft.

he leakage rate is then determined by plottirg air mass as a function of time, using a least p fit to determine the slope, A = dM/dr. W e leakage rate is expressed as a percentage of the air mass lost in 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or symbolically:

Irakage Rate = A/B(-2400) 3.2-2

Where A is the slope of the least-squares curve ard B is the y-intercept. 'Ihe sign convention is sx:h that the leakage out of containment is positive, ard the units are in percent / day.

The air mm is calculated ard the result is carrulated as a function of time by means of a least-squares curve fit of the form:

M = At + B A confidence interval is min 11ated usirq a Student's T distribution. 'Ihe sum of the leakage rate and confidence is the Upper Confidence Invel.

1 1

1 1

l l

l 3.2-3 l

i

9 I

r I

3.3 TEST RESULTS l

3.3.1 Presentation of Test Results The test data for the November 1993 IIRT is based on an 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> test period starting at 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on November 9,

1993.

The final test results were determined using Stone & Webster Engineering Cu ru.ation's IIRT conputer j

s up am.

'Ihe MM Input Data, Mass. Point Analysis Test Results, SuperiW IW Verification-Test Results, and tar =.=autive pol s are -

2 contained in Attachwent:i 3.3A through 3.3F.

r The Mass Point Analysis Test Results for the IIRP satisfied the rucidural f

acceptarx:e criteria.

i The IIRT instrumentation was verified by the Super 4W Isakage Verification.

Test Method. ' The Mass Point Analysis Test Results for the Superi= mad Isakage Verification Test satisfied the rucidaral acceptance criteria.

t t

l l

t i

j I

I J

l 3.3-l l

l

3.3.2 59.4 PSIA IIRT Results

'Ihe IIRT was conducted in accordance with Beaver Valley Power Station Unit No.

2 test procedure 2BVT 1.47.2.

'Ihe results for the IIRP and for the Supplemental Test are shown below:

3.3.2.1 IIRP Results - Mass Point Analysis Item (Pertxmt/ Day) 1.

Iam, Isakage Rate Calculated 0.038918 2.

Confidence IcVel 0.001192 3.

UCL, lam Icakage Rate plus Confidence 0.040110 level 4.

Corrections for:

(See Section 3.3.2.3) 1.

Type B Penalties 0.000123 ii. Type C Penalties 0.000742 lii. Water Invels 0.000000 iv. 'Ibtal Corrections 0.000865 5.

'Ibtal Reported IIRP Isakage Rate 0.040975 (Items 3 ~

')

Results were within the acceptable limits of < 0.75 Ia or < 0.075 Percent / Day l

l 3.3-2 l

l

l 3.3.2.2 Supplemental Test Results

'Ibe supplemental Verification Test was performed using the SuperiW Isakage Verification Test Method in accordance with test sur.=:dare 2BVT 1.47.2.

'Ihe results for the SuperiW Isakage Verification 'Ibst are shown below.

t 1.

'Ihe SuperiW Isakage Verification Test is acceptable provided Ic falls within the following range:

i I

(Iam + In - 0.251a) s Ic 5 (Iam + Io + 0.25La)

Where:

Lam = Type A calculated leakage (conputer)

= 0.038918 Percent / Day In = Super 1W leakage rate developed frcan rotameter i

= 0.10193 Fuuud./ Day l

l Ic = Ctmposite leakage (ocuputer)

= 0.116522 l

1 l

i d.

Mass Point I

i (0.038918 + 0.10193 - 0.025) $ 0.116522 5 (0.038918'+ 0.101193 + 0.025)

(0.115848) s 0.116522 s (0.165848)-

4

'Ihe SuperiW Isakage Verification 'Ibst was within the allowable limits.

l l

3.3-3 l

3.3.2.3 Leakage Penalties NWvi to IIRT Leakage Penetration leakage to be added since these penetrations were isolated or could not be vented and drained during the IIRP.

'Ihe leakage assigned is the recorded value for minimum pathway leakage.

i. Tvoe B Penalties Description Leakace (SCF/D)

Electrical 0-Rings 8.55 Penetrations

'Ibtal Type B Leakage = 8.55 SCP/D

'Ibtal Type B Irakage = 0.000123 Percent / Day li. Tvoe C Penalties Description Irakace (SCF/D) l Pent #1 Camponent Cbolirg Water System 9.71 Pent #2 Ocx:ponent Cboling Water System 17.96 Pent #4 Ccxuponent Cooling Water System 6.30 Pent #5 Couponent Cboling Water System 11.66 Pent #14 Chilled Water System 0.48 Pent #21 Chilled Water System 0.49 Pcnt #24 RHS System to FWSP 0.49 Pent #25 Chilled Water System 0.48 Pent #27 Chilled Water System 0.49 Pent #28 RCS Istdown 0.48 Pent #56-2 RCS Sample System 0.49 Pent #97-1 RHS Sample System 0.49 Pent #99 Fire Protection 0.49 Pent #101 Fire Protection 0.49 Pent #116 Fire Protection 0.49 Pent #117 Fire Protection 0.49 l

'Ibtal Type C Icakage = 51.48 SCP/D l

' Ictal Type C Is -kvie = 0.000742 Percent / Day 3.3-4 l

_._1.

a

.h 111. Water Level Cvu ctions Description Isakage (SCF/D) i Rx Vessel

0. 0 "

Cnet Sung 0.0 l

r i

Total Water Invel Cvu=ctions = 0.0 SCF/D Total Water Invel Cutoctions = 0.0 Fw.vait/ Day.

l i

a l

s i

l i

i c

.i

+

3.3-5

b j

i 1

3.3.2.4 As Found Containment Condition - IIRT Inprovements In order to account for the affect of Im.al Isakage Rate Test (IIRT) repairs (made prior to the IIRP) on the "as found" condition of containment, an analysis of IIRT results was performed.

The "as found" minimm pathway leakage rate is reviewed against the "as left" i

minimum pathway leakage rate for eadi LIRT per==Ls.ation.. If the perewation minimum pathway leakage rate is r M W because of repairs, maintenance, design L

changes, etc.,

then the leakage rate inprovement is noted. 'Ihe total of all f

these leakage rate improvements is the adjustment to the "as found" containment condition.

The minimum pathway leakage rate for the following IIRP penetrations was reduced as a result of repairs:

AS FOUND MINDEM AS LEFT MINIMLM IEAKAGE PA'IMMY LEAKAGE PA'IH&Y LEAKAGE DmueNCE PEtTP :%

(SCF/D)

(SCP/D)

(SCP/D)

  1. 11 0.97 0.49 0.48
  1. 38 1.46 0.49 0.97 l
  1. 87 10.10 9.27 0.83
  1. 106 0.50 0.49 0.01 L

Total Minimum Pathway Isakage Rate Inprwement = 2.29 SCF/D l

Total Minimum Pathway Isakage Rate Improvement = 0.000033 Percent / Day' T

Adding this "as found" containment adjustment to the reported IIRT results yields the following results:

Item (Fu u::nt/Dav) 1.

Total Reported IIRT Isakage Rate 0.040975 (See Section 3.3.2.1) 2.

As Idund Containment Adjustment 0.000033 3.

Total Containment Isakage Rate 0.041008 3.3-6

3.3.3 Conclusion No significant leakage paths were identified during the performance of the IIRP.

Containment teq mrature stabilization significantly influenced the mass trend, which directly affected the containment leakage and the test duration.

At the start of the test, it appeared that the containment steel liner and concrete shell were at a lower tenperature than the containment atmosphere.

Therefore, during the performance of the test, the liner and shell absorbed heat from the containment ahnnaphere until the difference in teraperature was minimal.

Without the assistance of forced ventilation, the tenperature stabilization took much longer than previously a ne d.

No ventilation equipment was operated during the BVPC #2 November IIRP.

Consideration for future IIRr's will be given to use forced ventilation in containment prior to the start of the IIRT. One possibility might involve operation of one of more Containment Air Recirculation Fans for at least 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the start of pressurization, in an attenpt to equalize the liner and shell tenperature with the containrrent atmosphere.

Also, the pressurization air tenperature should be maintained as close as possible to the containment atnosphere ten 1perature, even if the pressurization rate must be decreased.

l l

b t

3.3-7

l l

l l

l ATI7GMENT 3.2A l

INSTRUMENIATION IISP l

Weight Instntment Factor Rame Zgag Elevation A.

TempaJature 2 INS-TE100-1 0.05810 60 - 100 *F II 781' 21MS-TE100-2 0.06915 60 - 100 *F III 801' 6" 2 INS-TE100-3 0.05550 60 - 100 'F V

701' 6" 2IES-TE100-4 0.03610 60 - 100 'F IV 745' 6" 2IMS-TE100-5 0.07440 60 - 100 'F I

865' 2IMS-TE100-6 0.06915 60 - 100 *F III 791' 2IES-TE100-7 0.05810 60 - 100 'F II 781' 2 IRS-TE100-8 0.02340 60 - 100 'F IV 743' 2 IRS-TE100-9 0.03880 60 - 100 'F V

701' 6" 2 INS-TE100-10 0.07440 60 - 100 'F I

8658 2 IRS-TE100-11 0.02730 60 - 100 *F IV 730' l

2U4S-TE100-12 0.06915 60 - 100 *F III 794' 2 IRS-TE100-13 0.06915 60 - 100 *F III 802' l

2 INS-TE100-14 0.06680 60 - 100 *F V

701' 6" 2IES-TE100-15 0.05810 60 - 100 'F II 777' 4" 2 IRS-TE100-16 0.03880 60 - 100 'F V

701' 6" 21MS-TE100-17 0.07440 60 - 100 *F I

865' 2IES-TE100-18 0.03920 60 - 100 *F IV 7266" 2 IRS-TE100-19 0.00000 60 - 100 'F N/A 741' 2IFG TE100-20 0.00000 60 - 100 'F N/A 727' i

b i

Page 1 of 2 i

I

ATIAWMENT 3.2A (continued)

INSIMMNIATICH LISP Weight Instrument Factor Pame ZgDe Elevation B. Dewpoint 2IMS-ME100-1 0.111624 122*F I

848' 2LMS-ME100-2 0.111624 122*F I

848' 2 INS-ME100-3 0.258917 122'F II 701' 2 IRS-ME100-4 0.258917 122*F II 701' 2IES-ME100-5 0.258918 122*F II 701' C. Pressure I-I-2.3299 0.500000 0-100 PSIA I-I-2.6116 0.500000 0-100 PSIA.

D. Superimposed Irakace Verification Test Flow Instrument I-A-1.553.2 (FI-SIrl) 0.000000 0-8 SCFM I-A-1.553.3 (FI-SIe2) 1.000000 0-8 SOM Page 2 of 2

. =

4 ATIAWMENT 3.2B l

INSIMMENIATION SELECI'ICH GUIDE.

'Ihe Instrumentation Selection Guide (ISG) I far'mila is used to determine the ability of an instrumentation system to measure the integrated leakage of the reactor contai. Tent system.

Instrumentation errors are cambined using a root-sum-square forFnla.

The ISG is not AMai to the value of the calculated leakage rate, hit is used for instrument selection and loss of sensor criteria only.

Mrec:urvJment system sensitivity values are used in the ISG fornula since it is the change in the containment air mass, not the absolute value in mass, that is used to ca@ute leakage.

The following is the information used to calculate the ISG.

Quartz Chilled Motor 100 OHM-Manmeter Hvmu#wr Platinum RID Sensor Manufacturer

- D.H. Instruments General PYC0' Eastern Number of Sensors (n) 2 5

18 Parameter Measured Total Pressure, Dew Point, Tenperature PSIA (p)

'F (pv)-

'R (T)

Absolute Value 59.4 PSIA 60.'F 530 'R 1

1 l

i l

Page 1 of 3

)

ATDODENT 3.2B (ccritirnaad)

INS 1RMENIATICE SELBCTION GUIDE NorE:

Frcan the Steam Tables, at a dew point tenperature of 60 *F the equivalent water vapot. ptw a dm* is- 0.0092 PSIA /*F.

Sensor Sensitivity (E),

and Repeatability and Resolution (C)_

for the Hyp.um:ter's were converted to PSIA prior to calculating the total system error (e).

i Quartz Q1111ed Mirror Platinum Manameter Ihuudcer.

RID Sensor Sensitivity (E) 0.001 0.11 0.1 Repeatability and Resolution of System Excluding Sensor (C) 0 0.1 0.05 Tbtal System Error (e) 0.001

  • 6.1164E-04 0.02635 2 + C )/n)1/2 2

e = [(E The following equation was used to calculate the ISG:

1/2

-2

-2

--2 1

ISG =

2400 2

1

+ 2 gy

+ 2 A

e t

p p.

T i

)

where:

t = test duration, Hours

  • p = system error for pressure, PSIA

= system error for dewpoint, PSIA

= system error for tenperature, 'R This number was converted to equivalent water vapor pressure.

Page 2 of 3

l e

4 ATIAODENI' 3.2B (continued)

'1 INSIMMENIATION SEULTION GUIDE l

'Ihe ISG (24 Hrs) was calculated as follows:

v l

1/2-

-2

-2

-2 2400 0.001.

6.1164E-04 0.02635 ISG =

2

+2

+2 i

24 59.4 59.4 --

530.

-?

1/2 i

2400 ISG =

5.6684E-10 + 2.1206E-10 + 4.9436E l 24 1

l l

ISG =

0.00756 Pct / Day (Maxim m allowable ISG = 0.025 Pct / Day) j l

Time (t) at the naximum ISG was calculated as follows:

1/2 l

2400 t=

5.6684E-10

+ 2.1206E-10 + 4.9436E-09 0.025 t=

7.26 Hours Page 3 of 3

ATIAO MENT 3.3A INTEGRATED LEMGGE FATE TEST FBCH 1800 HOURS ON 11/9/93 'IO 1800 HOURS ON 11/10/93 RIDUCED INPUT VARIAMPA Time Press.

V.P.

Temp.

Dewpoint Mass (hh:mm)

(PSIA)

(PSI)

(R)

(F)

(LbM) 18:00 60.707 0.2463 531.851 58.902 526732.27 18:15 60.706 0.2461 531.845 58.887 526733.65 18:30 60.705 0.2467 531.836 58.949 526726.91 18:45 60.705 0.2463 531.820 58.905 526740.92 19:00 60.704 0.2457 531.807 58.839 526753.50 19:15 60.703 0.2458 531.821 58.853 526730.66 19:30 60.702 0.2460 531.805 58.870 526734.04 19:45 60.701 0.2464 531.805 58.921 526722.82 20:00 60.700 0.2467 531.811 58.947 526708.50 20:15 60.699 0.2466 531.799 58.936 526712.80 20:30 60.698 0.2468 531.778 58.959 526721.03 20:45 60.697 0.2467 531.786 58.946 526708.50 21:00 60.697 0.2468 531.792 58.959

.526695.99 21:15 60.696 0.2470 533 784 58.982 526694.34 21:30 60.694 0.2466 531.772 58.936 526698.11 21:45 60.694 0.2472 531.771 59.005 526689.32 I

22:00 60.693 0.2472 531.765 59.010 526686.35 22:15 60.692 0.2470 531.768 58.987 526674.45 22:30 60.691 0.2473 531.756 59.016 526677.46 22:45 60.691 0.2473 531.749

.59.016 526683.89 23:00 60.690 0.2463 531.755-58.902 526681.04 23:15 60.690 0.2469

-531.736 58.975 526689.92 23:30 60.689 0.2466 531.728 58.941 526692.06 23:45 60.688 0.2472 531.732 59.006 526675.18 00:00 60.687 0.2490 531.719 59.210 526663.16 00:15 60.686 0.2469 531.731 58.973 526664.81 00:30 60.685 0.2471 531.731 58.993 526654.28 00:45 60.685 0.2468 531.717 58.957 526666.06 01:00 60.684 0.2467 531.721 58.949 526659.27 01:15 60.683 0.2470 531.712 58.979 526657.79 01:30 60.683 0.2472 531.714 59.005 526649.70 01:45 60.682 0.2473 531.702 59.021 526651.29 02:00 60.631 0.2473 531.692 59.023 526654.11 02:15 60.681 0.2476 531.706 59.053 526632.98 02:30 60.680 0.2478 531.696 59.080 526636.30 l

02:45 60.680 0.2477 531.688 59.064 526640.49 03:00 60.679 0.2478 531.689 59.074 526633.07 03:15 60.678 0.2478 531.697 59.077 526617.46 03:30 60.677 0.2480 531.674 59.097 526633.14 l

03:45 60.677 0.2479 531.677 59.090 526625.94 l

04:00 60.677 0.2480 531.672 59.093 526629.93 i

04:15 60.676 0.2477 531.674 59.064 526621.37 l

04:30 60.675 0.2480 531.672 59.103 526613.66 04:45 60.675 0.2477 531.661 59.059 526624.17 05:00 60.674 0.2475 531.656 59.042 526627.21 05:15 60.673 0.2476 531.654 59.049' 526621.70 05:30 60.673 0.2471 531.652 59.001 526621.69 05:45 60.672 0.2475 531.636 59.043

.526628.10 Papa 1 of 2 l

ATDOMENT 3.3A IN1ERATED LEAIGGE RATE TEST IHCN 1800100RS CN 11/9/93 'IO 1800 IOURS ON 11/10/93 REDUCED IIRTF VARIABLES (continued) i Time Press.

V.P.

Temp.

Dewpoint Mass (hh:mm)

(PSIA)

(PSI)

(R)

(F)

(LbM)'

1 06:00 60.671 0.2476 531.634 59.049 526624.16 06:15 60.671 0.2468 531.639 58.959 526620.57-o 06:30 60.670 0.2476 531.640 59.049 526604.75 06:45 60.669 0.2477 531.637 59.059 526604.13 07:00 60.668 0.2477 531.623 59.062 526605.77 07:15 60.668 0.2476 531.629 59.053

.526598.08 07:30 60.668 0.2478 531.611 59.077 526611.74 07:45 60.666 0.2479 531.612 59.087 526600.27 08:00 60.666 0.2479 531.610 59.087 526597.84 08:15 60.665 0.2478 531.602 59.076 526600.16-08:30 60.664 0.2482 531.599 59.118 526592.52 08:45 60.664 0.2481 531.594 59.113 526594.82 09:00 60.663 0.2482 531.579-59.118

'526599.99 09:15 60.662 0.2481 531.583 59.112 526587.34 09:30 60.661 0.2481 531.579 39.105-526585.81 09:45 60.661 0.2484 531.576 59.141 526581.97 10:00 60.660 0.2485 531.582 59.158 526569.24.

10:15 60.659 0.2486 531.570 59.166 526574.51 10:30 60.659 0.2484 531.562 59.146 526582.'17 j

10:45 60.658 0.2478 531.557 59.074 526583.74' 11:00 60.658 0.2480 531.554 59.100 526579.08 l

11:15 60.656 0.2481

.531.549 59.106 526571.96' 11:30 60.656 0.2483 531.536 59.126 526580.97 11:45 60.655 0.2470 531.537 58.986 526580.40 12:00 60.654 0.2479 531.534 59.087 526570.69 12:15 60.653 0.2478 531.535-59.079 526563.30' 12:30 60.653 0.2482 531.528 59.120 526568.34 i

12:45 60.653 0.2480 531.531 59.097-526559.78, 13:00 60.652 0.2484 531.515 59.141 526566.88 13:15 60.651 0.2483 531.521 59.134 526553.36 13:30 60.651 0.2484 531.5111 59.141' 526559.72 13:45 60.650 0.2486 531.511 59.164 526549.55 14:00 60.649 0.2486 531.495

-59.164 526561.91 14:15 60.649 0.2487 531.493 59.179' 526556.78 14:30 60.648 0.2488 531.492 59.189.

526548.25 14:45 60.647 0.2487 531.480 59.177' 526557.93 15:00 60.647 0.2487 531.475 59.179

.526562.23 15:15 60.646 0.2490 531.482 59.213 526541.53 15:30 60.645 0.2488 531.473 59.185 526547.58 15: 45 60.645 0.2491 531.471 59.219

-526545.21 16:00 60.645 0.2491 531.462 59.223 526546.75 16:15 60.644 0.2488 531.467 59.191 526536.64 16:30 60.643 0.2471 531.467 58.998 526543.25 16:45 60.642 0.2489 531.463

.59.200 526526.00 17:00 60.642 0.2491 531.459 59.221 526528.73 17:15 60.641 0.2483 531.442-59.131 526545.25 17:30 60.641 0.2487 531.445 59.177 526534.55-17:45 60.640 0.2486 531.435 59.164 526541.45-18:00 60.639 0.2487 531.440 59.179-526527.67 l

Page 2 of 2

l

)

I ATUGMENT 3.3B INrB2ATED LEAKAGE RATE TEST MM 1800100RS ON 11/9/93 'IO 1800 HOURS.CH 11/10/93-j ABSOIUTE TEST MEMOD, MASS POINT ANALYSIS TESP MPIHOD Time Mass-Leakage.

Confidence

-UCL~

(hh:mm)

(LbM)

(PCT./ DAY)

(PCT./ DAY) _

(PCT./ DAY) q 18:00 526732.27 0.000000 0.000000 0.000000 18:15 526733,65 0.000000

'O.000000-0.000000 18:30 526726.91

-0.048834 0.365898 0.414732 i

18:45 526740.92

-0.034991 0.153108 0.118118 19:00 526753.50

-0.090615 0~103547 0.012932-19:15 526730.66-

-0.034100 0.092763

.0.058664 19:30 526734.04

-0.016868 0.065159' 0.048291 19:45 526722.82 0.008761-0.054957 0.063718 20:00 526708.50 0.037535.

0.052090 0.089625 l

20:15 526712.80' O.045858 0.041753 0.087611 L

20:30 526721.03 0.041501 0.033921 0.075423 l

20:45 526708.50 0.046169 0.028330 0.074499' 21:00 526695.99 0.054987 0.025425 0.080412 21:15 526694.34 0.059817 0.022172 0.081990~

21:30 526698.11 0.059744

'O.019080

.0.078824 21:45 526689.32 0.061911-0.016740 0.078651 22:00 526686.35 0.063246 0.014756 0.078001 22:15 526674.45 0.066878 0.013561 0.080438 22:30 526677.46 0.067555 0.012104 0.079659 i

22:45 526683.89 0.065410 0.011067 10.076476-l 23:00 526681.04 0.063646 0.010136 0.073782 23:15 526689.92-0.059649

-0.010014 0.069663 23:30 526692.06

'O.055535-0.009994 0.065529' 23:45 526675.18 0.054888 0.009163 0.064051 00:00 526663.16 0.055900'

-0.008472 0.064372 00:15 526664.81 0.055961 0.007806 0.063767 00:30 526654.28 0.057088 0.007301 0.064389 t

00:45 526666.06' O.055982 0.006856 0.062838 01:00 526659.27 0.055557

'O.006387 0.061945 01:15 526657.79 0.055028 0.005976

'O.061004.

l 01:30 526649.70 0.055153 0.005585 0.060738 01:45 526651.29 0.054778 0.005243 0.060021 5

02:00 526654.11 0.053900 0.004994 0.058894 i

02:15 526632.98-0.054837 0.004784 0.059622' 02:30 526636.30 0.055074 0.004512-0.059586 02:45 526640.49 0.054681 0.004275 0.058956 03:00 526633.07 0.054692 0.004041 0.058733' 03:15 526617.46 0.055632 0.003933 0.059565 l

03:30 526633.14 0.055121 0.003762 0.058883-i 03:45 526625.94 0.054962 0.003574 0.058536' 04:00 526629.93 0.054380 0.003445-0.057825 04:15 526621.37 0.054215 0.003282 0.057498 04:30 526613.66 0.054346 0.003130 0.057476 04:45 526624.17 0.053714 0.003049 0.056763.

05:00 526627.21 0.052847 0.003031

-0.055878 05:15 526621.70 0.052220 0.002961

'0.055181 05:30 526621.69 0.051531 0.002911 0.054442 05:45 526628.10 0.050496 0.002963

-0.053460' I

Page 1 of 2

i l

l

~.

ATIA0iMDE 3.3B l

INTIERATED IDJGGE RATE TEST l

FRCH 1800 HOURS ON 11/9/93 'IO 1800 HOURS ON 11/10/93 l

ABSOLUTE TEST MEH10D, MASS POINF ANALYSIS TESP MEIHOD l

(continued)

Time Mass Leakage Confidence UCL (hh:mm)

(LbM)

(PCT./ DAY)

(PCT./ DAY)

(PCT./ DAY) 06:00 526624.16 0.049635 0.002961 0.052596 06:15 526620.57 0.048910 0.002927 0.051837 06:30 526604.75 0.048808 0.002813 0.051621 06:45 526604.13 0.048636 0.002709 0.051345 07:00 526605.77 0.048319 0.002623 0.050942 07:15 526598.08 0.048221 0.002527 0.050748 l

07:30 526611.74 0.047554 0.002518 0.050072 l

07:45 526600.27 0.047259 0.002444 0.049703 08:00 526597.84 0.046990 0.002372 0.049362 08:15 526600.16 0.046590 0.002322 0.048912 08:30 526592.52 0.046387 0.002251 0.048638 08:45 526594.82 0.046059 0.002198 0.048257 09:00 526599.99 0.045540 0.002184 0.047724 09:15 526587.34 0.045353 0.002120 0.04747e 09:30 526585.81 0.045158 0.002061 0.047219 09:45 526581.97 0.045016 0.002001 0.047017 10:00 526569.24 0.045149 0.001943 0.047092 l

10:15 526574.51 0.045078 0.001885 0.046963 l

10:30 526582.17 0.044770 0.001852 0.046622 10:45 526583.74 0.044394 0.001833 0.046228 l

11:00 526579.08 0.044101 0.001802 0.045903 11:15 526571.96 0.043936 0.001757 0.045693 11:30 526580.97 0.043540 0.001750 0.045289 11:45 526580.40 0.043138 0.001744 0.044882 12:00 526570.69 0.042917 0.001709 0.044626 12:15 526563.30 0.042812 0.001666 0.044478 12:30 526568.34 0.042574 0.001637 0.044211 12:45 526559.78 0.042471 0.001597 0.044068 13:00 526566.88 0.042204 0.001576 0.043780 13:15 526553.36 0.042155 0.001536 0.043691 13:30 526559.72 0.041960 0.001509 0.043469 13:45 526549.55 0.041912 0.001472 0.043384 l

14:00 526561.91 0.041627 0.001461 0.043088 14:15 526556.78 0.041407 0.001441 0.042848 14:30 526548.25 0.041301 0.001409 0.042711 14:45 526557.93 0.041020 0.001402 0.042422 15:00 526562.23 0.040660 0.001412 0.042072 15:15 526541.53 0.040594 0.001380 0.041974 15:30 526547.58 0.040415 0.001359 0.041774 15:45 526545.21 0.040249 0.001338 0.041587 16:00 526546.75 0.040044 0.001322 0.041366 16:15 526536.64 0.039957 0.001295 0.041252 16:30 526543.25 0.039761 0.001281 0.041042 16:45 526526.00 0.039770 0.001253 0.041023 17:00 526528.73 0.039717 0.001227 0.040944 17:15 526545.25 0.039439 0.001230 0.040669 17:30 526534.55 0.039280 0.001213 0.040493 17:45 526541.45 0.039024 0.001213 0.040237 18:00 526527.67 0.038918 0.001192 0.040110 Page 2 of 2 l

l

BEAVER VATIFY POWER STATION UNIT NO. 2 INTEGRATED LEAKAGE RATE TEST ATIAOMENT 3.3C - OMP AIR MASS vs TIME Vol 2

Mass 526753-Beaver Uallev 2 - 1993 ILRT rre irc rri e rre rre nre irr itra ivr irrri rrr irr e irr e rr e irri rr e irr eir nrr e irr err e irri re nvri rr i rrr e ir e 526731-

[

526708- --- -- - - : - - --

+-

528685-526662-

- - ~~- - --

a m

M E

526640-n J-526617-

- -+-- - ------

-l---

+

5 526594-526572-J-

526549-

...j 52.,2e 0

4 8

12 18 20' 24 Tisse - (Hours >-

i 4

$*.c i

6 3g Tj

.gj....q T

... g

.s.

Fj

$ 1*

s 3

l

(

i

~

l

e t

...q.

.g.

.J..

...N i

l l

f r

l g.

i N

g ;

m W >:

O L 2 g.

Z g g:

ul 1

M:

8 3

j

% pg 0

l

..,w 4

i C.

y

.I

.t.

.g.

....t..

.l..

i c.

~.

l I

.\\

W N-E 3*

'a

  • H g.

j 0.=.

Ig i

.... CD l

m 3

l H

a l

l g:

l k

l

)

h g

g g:

3 i

i s-l

@CD:

..t.

..l....

.l..

l l

i

'j l

f 4m.

ei l

l 1

O I

i i

i i

i

.I I

I l

s C

m n

N O

C.

C.

O.

C.

C.

C.

C.

C.

C.

C.

C C

C C

C C

C C

.C.

.c c

MG / IC l

l l -

L

ATDGMENT 3.3E SUPERIMPOSED LEAKAGE VERIFICATICH TEST 7

FRCH 1900 EX.RS _ON 11/10/93 70 2300 HXRS ON 11/10/93' REDUCED INPUT VARIARTFS Time Press.

V.P.

Temp.

Dewpoint ~

Mass

~

(hh:mm)

(PSIA)

(PSI)

(R).

,(F)

.(LbM) 19:00 60.635

.0.2489 531.422-59.195 526506.'22 19:15 60.633-0.2491 531.423

-59.225-526488.44-19:30 60.633 0.2489 531.426

.59,196.

.526482.66 t

19:45 60.632 0.'2491

.531.409' 59.222

.526486.16 20:00-60.630 0.2493

~ 5 31. 4 09.

59.248 526470.62 20:15 60.629 0.2492 531~.412 59.228-526463.95-l 20:30 60.628-0.2494

.531.399

-59.256 526462.47 20:45 60.627 0.2493 531.'390 59.244 526465.73 21:00' 60.626

'O.2495

.531.389 59.269-526456'01-21:15 60.625 0.2496 531.403-59.2791 526431.03.

21:30-60'.624 0.2493 5 31~. 3 91-59.246 526435.46:

i 21:45 60.623 0.2497 531.385-59.289,

-526428.43l 22:00 60.622 0'2495 531'.392-159.266

,526413.'27:

22:15 60.621-0.2493

.531.384-59.246..

526413.70-22:30 60.619-0.2493 531.380 59.246' 526404.77' 22:45 60.619 0.2485

. 5 31.- 3 7 7_'-

.59.157' 526410.16-E 23:00 60.617 0.2488 531.369

59.186-

~526405.60-1 L$

i i

2 1

i Page 1 of 1 i

l

i 4

ATI%CHMENT 3.3F s

SUPERIMPOSED LEAKAGE VERIFICATION TEST FRCH 1900 HOURS ON 11/10/93 20 2300 HOURS ON 11/10/93-i ABSOIUTE TEST ME1 HOD, MASS POINT ANALYSIS. TEST ME1EOD Time Mass Leakage Confidence

. UCL (hh:mm)

(LbM)

(PCT./ DAY)

(PCT./ DAY)-

(PCT./ DAY) 19:00 526506.22 0.000000 0.000000 0.000000-19:15 526488.44 0.000000 0.000000

-0.000000' 19:30 526482.66 0.214841 0.540810~

0.755651 19:45 526486.16

-0.120268 0.180906-0.301174 4

20:00 526470.62 0.133982 0.085638' O.219620 20:35 526463.95 0.136141 O.050829 0.186970-20:30 526462.47 0.125207 0.036275 0.161483' 20:45 526465.73.

0.-105264 0.034359~

0.139622'-

21:00.

526456.01 0.100762 0.026412

'O.127174 21:15 526431.03 0.117819 0.027624 0.145443-21:30 526435.46 0.118091 0.022236' O.140327 21:45

~526428.43 0.118635 0.018302 0.136937' 22:00 526413.27 0.124166 0.016364 0.140530 l

22:15 526413.70 0.123872 0.013911 0.137783 1

22:30 526404.77 0.124655 0.011997-0.136652 i

22:45 526410.16 0.120264 0.011350

-0.131613-23:00.

526405.60 0.116522 0.010658 0.127180 f

i l

i l

i a

I i

l i

1 Page 1 of 1

(

i i

l i

SIrrION 4 l

IDCAL LEAKAGE PATE TESTS (TYPES B AND C)

Incal Irak Rate Testing (LIRT) of contairunent penetrations is perfonned on a l

periodic basis (normally each refueling, but not oWing 24 months), in acconlance with 10 CFR 50 Appendix J ani Beaver Valley Power Station #2 7bchnical Specifications.

'Ihese IIRT's are performed by pressurizing the required penetrations with air or nitrogen and either measuring leakage across the containment isolation valves boundary (Type C), or across the resilient l

seals (Type B). The combined leakage rate of containment pernhations subject l

to IIRT's shall be less than 60 perant Ia, at a minimum test pressure of Pa.

l Additionally IIRT's (Total Volume Type B) are performed for each containment i

airlock at 6 month intervals in accortlance with 10 CFR 50 Appendix J, and Beaver Valley Power Station #2 Technical Specifications.

The Attachments for this section are:

i Attachment No.

Title i

4.1A Third Refueling (3/92 - 4/92) IIRT Data i

4.1B 1hird Refuelirg (3/92 - 4/92) IIRT Repairs 4.1C Fourth Refueling (9/93 - 11/93) IIRT Data I

4.1D Fourth Refueling (9/93 - 11/93) IIRP Repairs

)

)

4.1E Third and Fourth Fuel Cycle IIRT Data l

l l

1 4-1 i

i I

l ATIACHMDfI' 4.1A l

THIRD REEUELING TYPE C TEST RESULTS CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATION NO.

MARK NO.

TESTED LEAKAGE LEAKAGE LEAFACE IN OUT (SCF/D)

(SCF/D)

(SCF/D) 2CCP*MOV157-2 X

04-04-92 13.23 29.40 1

1 2CCP*MOV157-1 X

04 04-92 12.74 33.30 33.30 2CCP*RV105 X

PARALLEL WITH 2CCP*MOV157 1 2CCP*MOV150 2 X

04-06-92 88.03 88.03 2

2CCP*MOV150-1 X

04-06 92 78.25 78.25 88.03 2CCP*RV105 X

PARALLEL WITH 2CCP*MOV150-1 i

2CCP*MOV151 2 X

04-05 92 14.70 29.30 l

4 2CCP*MOV151-1 X

04-05-92 14.70 0.49 29.30 2CCP*RV103 X

PARALLEL WITH 2CCP*MOV151 1 1

2CCP*MOV156-2 X

04-06 92 14.20 14.20 5

2CCP*MOV156-1 X

04-06-92 2.45 2.45 14.20 2CCP*RV104 X

PARALLEL WITH 2CCP*MOV156-1 l

2IAC*MOV133 X

04-18-92 5.90 4.90 4,90 2IAC*MOV134 X

04-18-92 0.49 0.49 2SWS*MOV153 2 X

03-20-92 1.95 1.95 14 2 SUS *MOV153-1 X

03-20-92 2.92 2.92 2.92 25WS*RV153 X

PARALLEL WITH 25WS*MOV153-1 2CHS*MOV378 X

03-30-92 0.49 0.49 l

19 2CHS*473 X

PARALLEL WITH 2CHS*MOV378 0.49 2CHS*MOV381 X

04-14 92 9.80 0.49 2 SIS *42 X

04-15-92 0.49 0.49 4

i 20 2 SIS *41 X

04-26-92 0.49 0.50 0.50 2 SIS *RV130 X

PARALLEL WITH 2 SIS *41 TOTAL PENETRATION LEAKAGE FOR PACE 2 (SCF/D) 173.64 i

Page 1 of B i

l

l l

l ATIACHMDTt 4.1A (continued)

'IHIRD REFUELDU 'IYPE C TEST RESULTS CONTAINME':T AS FOUND AS LETT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRAT!CN 50.

MARK NO.

TESTED LEAKAGE LEAKAGE LEAXACE IN OUT (SCF/D)

(SCF/D)

(SCF/D) 25WS*MOV155-2 X

04 13-92 0.49 0.49 21 2SWS*MOV155-1 X

04 13-92 0.49 0.49 0.47 25WS*RV155 X

PARALLEL WITH 2SWS*MOV155-1 l

2RHS*107 X

04 04-92 0.49 0.49 l

24 2RHS*15 X

04-04 92 0.49 0.49 0.49 2RHS*RV100 X

PARALLEL WITH 2RHS*15 l

25WS*MOV154-2 X

03-20-92 0.49 0.49 l

25 25WS*MOV154-1 X-03-28 92 0.49 0.49 0.49 l

25WS*RV154 X

PARALLEL VITH 2SWS*MOV154 1 l

2 SUS *MOV152-2 X

04 13-92 0.49 0.49 27 25WS*MOV152-1 X

04-13-92 0.49 0.49 0.49 25WS*RV152 X

PARALLEL WITH 2SWS*MOV152-1 2CHS*A0V200A X

03 30 92 0.50 0.50 2CHS*A0V200B X

PARALLEL WITH 2CHS*A0V200A 2CHS*A0V200C X

PARALLEL WITH 2CHS*A0V200A 2B 1.4B 2CHS*HCV142 X

03-30 92 0.49 0.49 2CHS*RV203 X

04 08-92 0.49 0.49 2CHS*A0V204 X

03 30-92 0.49 0.49 2DGS*A0V108A X

04-03-92 0.49 0.49 l

29 2DGS*A0V108B X

04-03-92 0.49 0.49 0.49 l

2DGS*RV115 X

PARALLEL WITH 2DGS*ACV108B TOTAL PENETRATION LEAKAGE FOR PAGE 3 (SCF/D) 3.93 l

i l

Page 2 of 8 i

ATTAWMENT 4.1A (continued)

'111IRD REFUELD4G TYPE C TESP RESULTS CONTAINMENT AS FOUND AS LEFT ASSIGNED PEST VALVE DATE VALVE VALVE PENETRAT:CN S0.

MARK NO.

TESTED LEAKAGE LEAKAGE LE.W GE IN OUT (SCF/D)

(SCF/D)

( S C F,'D )

2DAS*A0V100A X

04-24-92 1.27 0.49 l

38 2DAS*A0V100B X

04-18-92 0.68 0.68 0.68 2DAS*RV110 X

PARALLEL VITH 2DAS*AOV100B 2SAS*15 X

03-17 92 59.07 1.23 42 1.23 2SAS*14 X

03-17-92 167.53 0.49 l

2CVS*93 X

04 07-92 587.50 5.87 l

43 5.87 2CVS*SOV102 X

04 01-92 0.49 0.49 2CVS*SOV1533 X

04-01-92 2.94 2.94 a4 4.15 1

2CVS*SOV153A X

04-17 92 318.20 4.15

{

j 2RCS*72 X

03-18-92 0.49 0.49 i

45 2RCS*A0V519 K

03-18-92 0.49 0.49 0.59 2RCS*RV100 X

PARALLEL VITH 2RCS*A0V519 l

l 2VRS*A0V109A2 X

03 26-92 0.49 0.49 48

.j 0.49-

)

2VRS*AOV109Al X

03-26-92 0.49 0.49 2RCS*68 X

04-03-92 3.91 3.91 49 i

3.91 2RCS*A0V101 X

04-03-92 3.42 3.42 2GNS*A0V101-2 X

04 15 92 32.30 32.30 53 32.30 l

2GNS*A0V101-1 X

04-15-92 0.50 0.50 2SSR*A0V109Al X

04 03 92 0.49

.0.49 55-1 2SSR*A0V109A2 X

04-03-92 0.49 0.49 0.49 2SSR*RV117 X

PARALLEL VITH 2SSR*A0V109A2 TOTAL PENETRATION LEAKAGE FOR PAGE 4 (SCF/D) 49.61 Page 3 of 8 l

l

=

ATIACH4ENT 4.1A (ccritinued) 1 THIRD REEUELDG TYPE C TESTP RESULTS 1

i CONTAINMENT AS FOUND AS LEFT ASSICSE3 PENT VALVE DATE VALVE VALVE PENETRAT!:S l

)

e NO.

MARK NO.

TESTED LEAKAGE LEAKAGE LEAKAGE l

IN OUT (SCF/D)

(SCF/D)

(SCF/D) 2SSR*SOV;;JAl X

04-20 92 0.49 0.49 55-2 0.;9 2SSR*SOV130A2 X

04 20 92 0.49 0.49 i

2HCS*SOV136A X

03-23 92 0.49 0.49 55-3 j.

0.e9 l

2HCS*SOV136B X

04-06-92 0.49 0.49 l

l 2SSR*A0V102Al X

04 16 92 0.49 0.49 56-1 2SSR*A0V102A2 X

04-16 92 0.49 j

0.49 0.49 l

2SSR*RV118 X

PARALLEL WITH 2SSR*A0V102A2 2SSR*A0V128Al X

03 21-92 4.39 4.39 56-2 2SSR*A0V128A2 X

03 21-92 24.39 24.39 24.39 2SSR*RV120 X

PARALLEL VITH 2SSR*A0V128A2 2SSR*A0V100A1 X

03-21 92 0.49 0.49 56-3 2SSR*A0V100A2 X

04 01-92 0.49 0.49 0.49 i

2SSR*RV119 X

PARALLEL WITH 2SSR*A0V100A2 2SSR*A0V112Al X

04 03 92 0.49 0.49 57-1 2SSR*A0V112A2 X

04 03 92 9.79 9.79 9.79 2SSR*RV121 X

PARALLEL WITH 2SSR*A0V112A2 2HCS*SOV135A X

03 23-92 0.98 0.98 57-2 0.98 2HCS*SOV135B X

03 23-92 0.98 0.98 2IAC*22 X

03 19 92 0.49 0.49 59 0.98 2IAC*MOV130 X

04 07 92 0.49 0.98 TOTAL PENETRATION LEAXAGE FOR PAGE 5 (SCF/D) 38.10 l

l l

I l

Page 4 of 8

ATIACIMENT 4.1A (continued)

THIRD REEUILDU TYPE C TESTP RESULTS l

i CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATICN No.

MARK NO.

IESTED LEAKAGE LEAKAGE LEAFACE IN OUT (SCF/D)

(SCF/D)

(SCF/D) 2QSS*4 X

04-18 92 0.49.

0.49 63 2QSS*MOV101A X

04 14-92 0.49 7.83 7.83-2QSS*RV101A X

PARALLEL WITH 2QSS*MOV101A 2QSS*3 X

04 20-92 19.60 1.95 64 2QSS*MOV101B X

04 20 92 0.49 3.41 3.41 2QSS*RV101B X

PARALLEL WITH 2QSS*MOV101B 2HCS*111 X

ja3-1792 10.34 10.34 10.34 2HCS*MOV117 X

v3-17-92 10.34 10 34 2HCS*110 X

03-17-92 0.49

'O.49 88 2HCS*MOV116 X

03-17-92 0.49 0.49 0.49 2HVR* MOD 23B X

90 04 04-92 195.10 142.00 142.00 2HVR* MOD 23A X

2HVR* MOD 25B X

91 2HVR* MOD 25A X IO4 04 92 536.50 102.80 102.80 2HVR*DMP206 X

2HCS*SOV114B X

03-31 92 0.98 0.98

~

(

2HCS*SOV115B X

03-31-92 0.98 0.98 92 18,60 2CVS*SOV151B X

03-31-92 0.98 0.98 2CVS*SOV152B X

03 31 92 17.62 17.62-2HCS*SOV114A X

03 31 92 14.70 14,70 2HCS*SOV115A X

03-31 92 13.72 13.72 93 2CVS*SOV151A X

03 31-92 15.18 15.18 29.88 2CVS*SOV152A X

03 31-92 10.29 10.29 TOTAL PENETRATION LEAKAGE FOR PAGE 6 (SCF/D) 315.35 l

Page 5 of 8 l

ATIACHMDir 4.1A (continued)

THIRD REFUELI'G TYPE C TEST RESULTS CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATICN NO.

MARK NO.

TESTED LEAXACE LEAKAGE LEAXACE IN CUT (SCF/D)

(SCF/D)

(SCF/D) 2CVS*151 X

03-16 92 5.91 5.91 94 5.91 2CVS*151-1 X

03-16 92 0.49 0.49 2SSR*A0V129Al X

03-21-92 29.26 29.26 97 1 2SSR*A0V129A2 X

04-20-92 0.49 0.49 29,26 2SSR*RV122 X

PARALLEL WITH 2SSR*A0V129A2 2HCS*SOV1J38 X

03-23 92 0.49 0.49 97-2 0.49 2HCS*SOV134B X

03-23-92 0.49 0.49 2FPW*761 X

04 15 92 0.49 0.49 99

'1.71 2 FPW*A0V206 X

04 02-92 1.71 1.71 2FPW*753 X

04-01 92 0.49 0.49 101 1,47 2FPW*A0V205 X

04 01-92 1,47 1.47 2FNC+121 X

04-03-92 0.49 0.49 103 0.49 i

2FNC*38 X

04-03-92 0.49

'O.49 1

2 FNC*122 X

04-03 92 0.49 0.49 104 0.49 2FNC*9 X

04-03-92 0.49 0.49 2HCS*SOV133A X

03-23-92 3.75 3.75 105 1 3.75 2HCS*SOV134A X

03-23-92 0.49 0.49 2 PAS *SOV105A1 X

04 19-92 0.98 0.98 105-2 1.17 2 PAS *SOV105A2 X

04-19-92 1.17 1.17 2LHS*51 X

03-22-92 0.49 0.49 105-3 0.49 2LMS*52 X

03 22 92 0.49 0.49 l

TOTAL PENETRATION LEAXACE FOR PAGE 7 (SCF/D) 45.23 Page 6 of 8 l

ATIACHENT 4.1A (continued)

~.

THIRD REFUELDJG TYPE C TESP RESULTS CONTAINMENT AS FOUND AS LEFT ASSIGNED f PENT VALVE DATE VALVE VALVE PENETRATION NO.

MARK NO.

TESTED LEAKAGE LEAKAGE LEAKAGE IN OUT (SCF/D)

(SCF/D)

(SCF/D) 2 SIS *MOV842 X

03-20-92 0.50 0.50 106 2 SIS *A0V889 X

03-23 92 0.50 0.49 0.50 2 SIS *RV175 X

PARALLEL WITH 2 SIS *A0V889 2FPW*388 X

04-06-92 0.49 0.49 116 0. /. 9 2FFW*A0V221 X

03-28-92 0.49 0.49 2FPW*382 X

04-07-92 9.79 0.49 117 14.69 2FPW*A0V204 X

03-28 92 14.69 14.69 2QSS*267 X

04 18-92 0.49 0.49 118 2QSS*SOV100A X

04-13-92 8.84 8.84 8.84 2QSS*SOV100B X

PARALLEL tiIT1: 2qSs*S0y100A TOTAL PENETRATION LEAKAGE FOR PAGE 8 (SCF/D) 24.52 TOTAL PENETRATION LEAKAGE PAGE 2 0F (SCF/D) 173.64 TOTAL PENETRATION LEAKAGE PAGE 3 0F

.(SCF/D) 3.93 TOTAL PENETRATION LEAKAGE PAGE 4 0F (SCF/D) 49.61' TOTAL PENETRATION LEAKAGE PAGE 5 OF (SCF/D) 38.10 TOTAL PENETRATION LEAKAGE PAGE 6 0F (SCF/D) 315.35 TOTAL PENETRATION LEAKAGE PAGE 7 0F (SCF/D) 45.23 TOTAL PENETRATION LEAKAGE PAGE 8 0F (SCF/D) 24.52 TOTAL CONTAINMENT TYPE C LEAYAGE - SUM OF PAGES 2 THRU 8 (SCF/D)650.38 l

l Page 7 of 8 r

i ATIAGEENT 4.1A (continued)

THIRD REFUELDU TYPE B AND C TEST RESULTS P

l "AS FCUND" "AS LEFT" PENERTATION DATE PENETRATION PENETRATION l

(TEST PROCEDURE)

TESTED LEAKAGE LEAYAGE l

(SCF/D)

( S C F 'D )

ELECTRICAL PENETPATIONS 03-15-92 8.55 8.55 (2BVT 1.47.4)

FUEL TRANSFER TUBE FLG.

04 23-92 0.49 0.49 (2BVT 1.47.9)

EQUIPMENT HATCH 04-25-92 0.48 0.50 (2BVT 1.47.9)

EQUIP. HATCH INNER FLG.

04-26-92 0.48 0.51 (2BVT 1.47.9) l PERSONNEL AIRLOCK 04-24 92 48.54 0.49 (2BVT 1.47.8) l EMERGENCY AIRLOCK 04-26 92 8.01 13,03 (2BVT 1.47.10)

TOTAL PENETRATION LEAKAGE FOR PAGE 9 (SCF/D):

23.57 I

TOTAL CONTAINMENT TYPE C LEAKAGE - SUM OF PAGES 2 THRU 8 650.38 SCF/D TOTAL CONTAINMENT TYPE B LEAKAGE - SUM OF PAGE 9 23.57 SCF/D TOTAL CONTAINMENT TYPE B & C LEAKAGE - SUh Cr TAON 2 THRU 9 673.95 SCF/D l

Page 8 of 8

i l

l l

i ATIAGMENI' 4.1B

'IHIRD REFUELIIG IDCAL LEAKAGE RATE TEST REPAIRS Penetration No. 1

'Ihe "As-Found" leak test was performed on March 29, 1992. Static 10 VATS l

Testing was perform 3d on valves 2CCP*NOV157-1 per ME 6280 and 2CCP*)OV157-2 l

per MfR 6281.

Relief valve 20:P*RV105 was ruroved for In-Service Testing per MWR 2011. FollowlIg completion of the MOVATS testing and reinstallation of the relief valve, the "As-left" leak test was performed on April 4,1992 with acceptable leakage rates measured.

Penetration No. 4 The "As-Found" leak test was performed March 29, 1992. Static IOVATS 'Ibsting was performed on valves 2CCP*lOV151-1 per NWR 6278 and 2CCP*}0V151-2 per MWR 6279.

Also the inlet and outlet mounting flarge gaskets were replaced for valve 2CCP*lOV151-2 per MWR 906868. Following completion of the 10 VATS testing and replacement of the mounting flange gaskets a retest was performed on l

April 4,

1992.

Isakage was detected at the mounting flange gaskets for valve 2CCP*MOV151-2.

The gaskets were retorqued aM the "As-Left" leak test was performed on April 5,1992 with acceptable leakage rates measured.

Penetration No. 11

'Ihe "As-Found" leak test was performed March 18, 1992. Static MOVATS Testing was performed on valve 2IAC*lOV134 per MWR 6269. Follcwing completion of the MOVATS Testing, the "As-Inft" leak test was performed on April 18, 1992 with an acceptable leakage rate measured.

Penetration No. 19

'Ihe "As-Found" leak test was performed on Mart:h 30, 1992. Static 10 VATS Testing was performed on valve 2 GS*lOV381 per MWR 6282. Followiry completion of the MOVATS testirg, the "As-left" leak test was performed on April 14, 1992 with an acceptable leakage rato measured.

Penetration No. 20 l

The "As-Found" leak test was performed on April 15, 1992. After returning i

Penetration No., 20 back to service, leakage was detected from relinf valve 2 SIS *RV130.

NWR 9195 was written to remove and repair the relief valve.

Following reinstallation,_

the "As-Inft" leak test was performed on l

April 26, 1992 with an acceptable leakage rate measured.

l Penetration No. 24

'Ihe "As-Found" leak tast was performed March 31, 1992. Relief valve 2RHS*RV100 was renved for In-Service Testirq per MNR 2002 and the packing was adjusted for valve 2RHS*107 per MWR 7983.

Following empletion of the packirg adjustment ard reinstallation of the relief valve, the "As-left" leak test was perfonned on April 4,1992 with acceptable ledage rates measured.

l Page 1 of 5 l

l l

l l

ATIAQMENT 4.1B (continued)

THIRD REFUELING IOCAL LEAKAGE PATE TEST REPAIRS Penetration No. 25 The "As-Found" leak test was perfomed on Mardi 20, 1992. Relief valve 25WS*RV154 was re::cved for In-Service 7bsting per MWR 2015.

Foll wing reinstallation of the relief valve, the "As-Inft" leak test was performed on March 28, 1992 with an acceptable leakage rate measured.

Penetration No. 28 The "As-Found" leak test was perfomed on March 30, 1992. Relief valve 2CES*RV203 was removed for In-Service Testing per NWR 1999.

Follwing reinstallation of the relief valve, the "As-Inft" leak test was perfomed on April 8, 1992 with an acceptable leakage rate measured.

Penetration No. 38 The "As-Found" leak test was performed on April 18, 1992. The actuator diaphragm for valve 2DAS*AOV100A was replaced for preventive maintenance per MNR 8860.

Followirg the repair, the "As-Isft" leak test was performed on April 24, 1992 with an acceptable leakage rate measured, l

Penetration No. 42 The "As-Found" leak test was performed on March 16, 1992. Due to excessive seat leakage MWR's 7869 and 7870 were written for valves 2SAS*14 and 2SAS*15.

l The valve seating surfaces Wre cleaned for valve 2SAS*14 and the disc was replaced for valve 2SAS*15. Follwirg these repairs, the "As-Isft" leak test was performed on March 17, 1992 with acceptable leakage rates measured.

)

Penetration No. 43 The "As-Found" leak test was performed on April 1,1992. Due to excessive seat leakage, MWR 8434 was written for valve 2CVS*93. She valve seat and plug were lapped.

Follwing this repair, the "As-Inft" leak test was performed on April 7,1992 with an acceptable leakage rate measured.

Penetration No. 44 The "As-Found" leak test was performed April 1,1992. Due to excessive seat leakage MWRs 8435 was written for valve 2CVS*SOV153A. The valve soft seat was replaced.

Follwiry this repair, the "As-Inft" leak test was performed on April 17, 1992 with an acceptable leakage rate measured.

Page 2 of 5

ATIACHENT 4.1B (continued)

THIRD REWELDU IDCE MADGE RATE TEST REPAIRS Penetration 1:). 56-3 l

l The "As-Found" leak test was perfomed on March 21,-

1992. Relief valve 2SSR*RV119 was removed for In-Service Testiry per NWR 2009.

Following l

reinstallation of the relief valve, the "As-Inft" leak test was perfomed on April 1, 1992 with an acceptable leakage rate measured.

Penetration No. 59 l

The "As-Found" leak test was performed on March 19, 1992. Static HOVATS Testing was performed on valve 2IAC*10V130 per NWR 6268. Following cmpletion of the MOVATS testirg, the "As-Left" leak test was performed on April 7,1992 with an acceptable leakage rate measured.

Penetration No. 63 i

The "As-Found" leak test was perfomed on March 18, 1992. NWR 0751 was written prior to 3R for valve 2QSS*}OV101A due to a body to bonnet leak, also MNR 7986 was written for check valve 20SS*4 due to its weight arms birriing when the valve was fully opened.

The body to bonnet gasket was replaced for valve 2QSS*MOV103A and the shaft o-rings were replaced for check valve 2QSS*4. A retest of both valves was perfomed on April 7,1992 with acceptable leakage rates measured; however, durirs the perfomance of 2BVf 1.47.3, " Check Valve Lift Test",

leakage was detected at the body to bonnet gasket for valve 2QSS*10V101A.

NWR 8315 was written to repair the leak. The bonnet bolts were retorqued to a higher value; however, leakage was still detected..The body to bonnet gasket was replaced for a second time per MNR 8721 and the "As-Inft" leak test was successfully performed on April 14, 1992; however, check valve 2QSS*4 failed 2BVI 1.47,'

by liftirg at a lower than acceptable pressure.

IMR 8389 was written to repair the check valve. The spherical washer tint held the disc to the disc arm was machined to allow the disc to seat properly. The "As-Inft" leak test arx1 the " Check Valve Lift Test" were perfomed on April 18, 1992 with acceptable results obtained.

l Penetration No. 64 The "As-Found" leak test was perfomed on March 18, 1992. Relief valve 2QSS*RV101B was removed to repair the inlet thrmelwl connection per NWR 2201, the torque switch for valve 2QSS*MOV101B was replaced for 10CFR Part 50 concerns on the roll pin shearing per MNR 7278, and the shaft o-rings were replaced for check valve 2QSS*3 per HWR 7888 due to the weight arms binding when the valve was fully opened. Following ompletion of all the MRRs, the "As-Inft" leak test was performed on April 20, 1992 with acceptable leakage rates measured.

l Page 3 of 5 l

ATECHENT 4.1B (continued)

THIRD RmHLING IOCAL laDGE PATE TEST REPAIRS Penetration No. 90 The "As-Found" leak test was performed on Mard 19, 1992. Due to excessive packing leakage PER 8066 was written for motor operated damper 2HVR*}OD23A.

Paint was removed frcan the valve follower and the packing was adjusted.

Following this repair, the "As-Left" leak test was perfonned on April 4,1992 with an acceptable leakage rate measured.

Penetration No. 91 The "As-Found" leak test was performed on March 19, 1992. Due to excessive seat leakage MWR 8466 was written for motor operated danper 2HVR*)CD25A. 7he' close limit switch was adjusted to allow the valve to close further. Following this repair, the "As-Inft" leak test was performed on April 4, 1992 with an acceptable leakage rate measured.

Penetration No. 97-1 The "As-Found" leak test was performed March 21, 1992. Relief valve 2SSR*RV122 was removed for In-Service Testing per MWR 2010. Following reinstallation of the relief valve, the "As-Inft" leak test was performed on April 20, 1992 with an acceptable leakage rate measured.

j

^

Penetration No. 99 t

The "As-Fourvi" leak test was performed April 2, 1992 with ac ptable leakage rates measured; however, during the perfannance of 2BVT 1.47.3, "meck Valve Lift Test",

check valve 2FPW*761 lifting at a lower than acceptable pressure.

MWR 8487 was written to repair the valve. The valve disc was lapped to remove any imperfections.

The "As-Inft" leak test and the " Check Valve Lift 7bst" were performed on April 15, 1992 with acceptable results obtained.

Penetration No. 106 L

The "As-Found" leak test was performed March 20, 1992. Relief valve 2 SIS *RV175 was removed for In-Service Testing per NWR 2003. Following reinstallation of the relief valve, the "As-Isft" leak test was performed on March 23, 1992 with l

an acceptable leakage rate measured.

Penetration No. 116 The "As-Found" leak test was performed March 28, 1992 with acceptable leakage rates measured; however, during the performance of 2BVT 1.47.3 " Check Valve Lift Test",

the weight arms for check valve 2FPW*388 were binding when fully opened.

MWR 8343 was written to repair the valve. The shaft plug seat was found not centered over the valve lxxty causing the birding. A 1/8" spacer was installed to center the plug.

The "As-Inft" leak test and the " check Valve Lift Test" were performed on April 6,1992 with acceptable results obtained.

Page 4 of 5 l

l

.a ATIAGMENT 4.1B (corrtinued)

BURD RHELDU IOCAL IEAKAGE PATE TEST REPAIRS Peru bation No. 117 1

Se "As-Found" leak test was performed March 28, 1992 with acceptable leakage rates measured; however, during the performance of 2BVT 1.47.3 "dieck Valve Lift hst",

check valve 2FPW*382 lifting at a lower than acceptable pressure.

MNR 8344 was written to repair the valve. S e valve disc plug shaft was found to be installed backwards causing the weight arms not to lower to their opthmn i

position.

Se disc plug shaft was installed -afdy and a retest was performd on April 6, 1992. An acceptable leakage rate was measured for check i

valve 2FPW*382; however, it still lifted at a lower than acceptable pressure.

We disc seat was then replaced per the same PMR. he "As-Inft" leak test and the " Check Valve Lift Test" were performed on April _7, 1992 with acceptable results obtained.

Penetration No. 118 he "As-Found" leak test was performed April 13, 1992 with acceptable leakage rates measured; however, during the performance of 2BVT 1.47.3 " Check Valve Lift Test",

check valve 2QSS*267 liftirg at a lower than acceptable pressure.

MWR 8866 was written to repair the valve. h e valve disc and disc arm were replaced.

%e "As-left" leak test and the "dieck. Valve Lift Test" were performed on April 18, 1992 with acceptable results obtained.

1 I

Page 5 of 5

ATIACIiKENT 4.1C EARIH REEUELIlu TYPE C TESP RESULTS t

CONTAINMENT AS FOUND AS LEFT ASSIGNED j

PENT VALVE DATE VALVE VALVE PENETRATION NO.

MARK NO.

TESTED LEAKAGE LEAKACE LEAKAGE IN OUT (SCF/D)

(SCF/D)

(SCF/D) 2 CP*MOV157 2 X

10 09-93 9.71 9.71 1

2CCP*Mut157 1 X

10-09-93 14.56 14.56 14.56 2CCP*RV105 X

PARALLEL WITH 2CCP*MOV157-1 2CCP*MOV150-2 X

10-21 93 11.19 17.96 2

2CCP*MOV150 1 X

10-21 93 11.19 17.96 17.96 l

2CCP*RV102 X

PARALLEL WITH 2CCP*MOV150 1 2CCP*MOV151 2 X

10-09-93 6.30 6.30 4

2CCP*MOV151-1 X

10-15 93 5.33 8.76 8.76 i

l 2CCP*RV103 X

PARALLEL WITH 2CCP*MOV151-1~

i 2CCP*MOV156-2 X

10-21-93 11.19 11.66 5

2CCP*MOV156-1 X

10 21 93 11.19 12.63 12.63 2CCP*RV104 X

PARALLEL WITH 2CCP*MOV156 1 1

2IAC*MOV133 X

11-01 93 1.26 0.49 11 0.49 l

2IAC*MOV134 X

11-01-93 0.97 0,49 25WS*MOV153-2 X

09-24 93 0.48 0.48 14 2SWS*MOV153-1 X

10-19 93 0.48 0.49 0.49 2SWS*RV153 X

PARALLEL VITH 25WS*MOV153 1 2CHS*MOV378 X

10-18 93 1.70 0.49 19 2CHS*473 X

PARALLEL WITH 2CHS*MOV378 0.49 2CHS*Mov381 X

10 18 93 0.49 0.49 2 SIS *42 X

10 30 93 0.49 0.49 20 2 SIS *41 X

10-20-93 0.49 0.49 0.49 l

2 SIS *RV130 X

PARALLEL WITH 2 SIS *41 TOTAL PENETRATION LEAKACE FOR PAGE 2 (SCF/D)

5. "

Page 1 of 8

ATIN3PIENT 4.1C (continued).

FOURDI REEUELING TYPE C TESP RESULTS 9

CONTAINMENT AS FOUND AS LETT ASSIGNED PENT VALVE DATE VALVE' VALVE PENETRATION i

NO.

MARK NO.

TESTED LEAKAGE

=LEAXAGE LEAKAGE IN OUT.

(SCF/D)'

(SCF/D)

(SCF/D) 2SWS*MOV155 2 X

10-07 93 0.48 0.49

}

21 2SWS*MOV155-1 X

10-07 93 0.48 1,46 1.46 2SWS*RV155 X

PARALLEL WITH 25WS*MOV155-1 i

2RHS*107 X

10 13 93 0.49 0.49 24 2RHS*15 X

10 13 93

'O.49.

0.49 0.49 2RHS*RV100 X

PARALLEL WITH 2RHS*15

' L 2SWS*MOV154 2 X

09 24 93 0.48-0.48 25 25WS*MOV154 1 X

10 18-93 0.48 0.49 0.49 2SWS*RV154 X

PARALLEL WITH 2SWS*MOV154-1 25WS*MOV152-2 X

10 07-93 0.48 0.49 27 25WS*MOV152-1 X

10 07-93

-0.48 0'.49 0.49 25WS*RV152 X

PARALLEL WITH 2SWS*MOV152 1

' i 2CHS*A0V200A X

10 19-93 0.49 0.49 2CHS*A0V200B X

PARALLEL WITH 2CHS*A0V200A 2CHS*A0V200C X

PARALLEL WITH 2CHS*A0V200A 28 1.94-2CHS*HCV142 X

10 19-93 0.49 0.97-2CHS*RV203 X

10 08-93 0.48 0.48 2CHS*A0V204 X

10408-93 0.48 0.48 2DGS*A0V108A X

09 30 93 0.49 0.49 29 2DCS*A0V108B X'

09 30-93 0.49

0.49-

' O. 4 9 -_

-l 2DGS*RV115 X

PARALLEL WITH 2DCS*A0V108B TOTAL PENETRATION LEAKAGE FOR PAGE 3 (SCF/D)-

5. 3 6 '..

Page 2 of 8

l ATIAGEENT 4.1C (contira.ned) i RXIRIH REFUELING TYPE C TEST RESULTS I

l CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATION NO.

MARX NO, TESTED LEAKAGE LEAKAGE LEAXACE IN OUT (SCF/D)

(SCF/D)

(SCF/D) i 2DAS*A0V100A X

11 01 93 2433.90 0.49 38 2DAS*AOV100B X

11 01 93 1.46 0.49 0.49 2DAS*RV110 X

PARALLEL WITH 2DAS*A0V100B l

2SAS*15 X

09-20 93 1.96 1.96 42 39.38 l

2SAS*14 X

09-25 93 147.00 39 38 i

2CVS*93 X

09-24-93 0.49 0.49 43 l

2CVS*SOV102 X

09-24 03 0.49 0.49 0.49 i

2CVS*SOV153B X

09-24-93 3.18 3.18 44 4.89 2CVS*SOV153A X

09-24-93 4.89 4.89 2RCS*72 X

10 23-93 2412.00 0.73 45 2RCS*A0V519 X

11-11-93 0.48 0.49 0.73 2RCS*RV100 y

PARALLEL VITH 2RCS*A0V519 2VRS*A0V109A2 X

09-29-93 0,48 0.48 48 1.21 2VRS*A0V109Al X

09-29 93 1.21-1.21 2RCS*68 X

09 25 93 6.30 6.30 49 6.30 2RCS*AOV101 X

10 31-93 5.82 5.87 2GNS*AOV101-2 X

10 01 93 10.40 10.40 53 10.90 2GNS*A0V101 1 X

10-01 93 10.90 10.90 l

2SSR*A0V109Al X

09 28 93 0.49 0.49 j

l 55 1 2SSR*A0V109A2 X

10-18-93 0.49 0.49 0.49 2SSR*RV117 X

PARALLEL WITH 2SSR*A0V109A2 f

TOTAL PENETRATION LEAKAGE FOR PAGE 4 (SCF/D) 64.88 l

l Page 3 of 8

i I

l.,

ATIACEMENI' 4.1C (continued) l Pomm RENELING TYPE C TEST RESUUPS I

l l

CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATION NO.

MARK NO.

TESTED LEAYAGE LEAKAGE LEAKAGE IN OUT (SCF/D)

(SCF/D)

(SCF/D) l 2SSR*SOV130Al X

10 15 93 1.95 1,95 55-2 4.86 2SSR*SOV130A2 X

10 15-93 4.86 4.86 l

2HCS*SOV136A X

09 30-93 4.93 4.93 55 3 4.93 2HCS*SOV136B X

09-30-93 4.93 4.93 2SSR*A0V102A1 X

11 05-93 0.49 0.49 56-1 2SSR*A0V102A2 X

11-05 93 0.49 0.49 0.49 2SSR*RV118 X

PARALLEL VITH 2SSR*A0V102A2 2SSR*A0V128A1 X

11 14-93 0.49 0.49 t

j l

56-2 2SSR*A0V128A2 X

11 14-93 68.10 0.49 0.49 2SSR*RV120 X

PARALLEL WITH 2SSR*A0V128A2 i

2SSR*A0V100Al X

09-28 93 0.49 0.49 56 3 2SSR*A0V100A2 X

10-29-93 0.49 0.49 0.49 2SSR*RV119 X

PARALLEL WITH 2SSR*A0V100A2 2SSR*A0V112A1 X

09 28-93 0.49 0.49 57-1 2SSR*A0V112A2 X

10 29 93 0,49 2.43 2.43

)

l 2SSR*RV121 X

PARALLEL WITH 2SSR*A0V112A2 2HCS*SOV135A X

09 30-93 0.74 0.74 57-2 0.74 2HCS*S0V135B X

09-30 93 0.74 0.74 21AC*22 X

10-14 93 0.49 0.49 59 0.49 2IAC*MOV130 X

10-14-93 0.49 0.49 l

TOTAL PENETRATION LEAKAGE FOR PAGE 5 (SCF/D) 14.92 l

l Page 4 of 8

ATIACliMEtE 4.1C (continued)

FOURIH REFUELDE TYPE C TEST RESULTS CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATION NO.

MARX NO.

TESTED LEAXAGE LEAXACE LEAKAGE i

IN OUT (SCF/D)

(SCF/D)

(SCF/D) 2QSS*4 X

09-22-93 0.48

-0.48-63 2QSS*MOV101A X

11 12 93 0.96 16.11-16.11 2QSS*RV101A X

PARALLEL WITH 2QSS*MOV101A 2QSS*3 X

09-25-93 3.87 3.87-64 2QSS*MOV101B X

10-15-93 0.48 14.63 14.63 2QSS*RV101B X

PARALLEL WITH 2QSS*MOV101B 2HCS*111 X-09 22 93 10.10 10.10 87 10.10 2HCS*MOV117 X

11-06-93 10.10 9.27 2HCS*110 X

09-22-93 0.48 0.48 88 0.49 2HCS*MOV116 X

11-06-93 0.48 0.49 2HVR* MOD 23B X

90 10 02 93 159.00 262.40 262.40 2HVR* MOD 23A X

l 2HVR* MOD 25B X

91 2HVR* MOD 25A X

11-12 93 347.90 186.56 186.56 2HVR*DMP206 X

2HCS*SOV114B X

09 22-93 1.20 1.20 2HCS*SOV1158 X

09-22 93 1.20 1.20 92 28 70 l

2CVS*SOV1518 X

09 22-93 1.06 1.06 l

l 2CVS*SOV152B X

09 22 93 27.50

.27.50 2HCS*SOV114A X

09 23-93 11.60 11.60 2HCS*SOV115A X

09 23 93 7.73 7,73 93

{

24,16 2CVS*SOV151A X

09 23-93 12.56 12.56 i

1 I

l 2CVS*SOV152A X

09 23 93 5.31 5.31 i

TOTAL PENETRATION LEAXAGE FOR PAGE 6 (SCF/D) 543.15 Page 5 of 8 I

l l

ATIACHENT 4.1C (continued).

FOURIH REEUELING 'IY1 E C TESP RESULTS j

CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATION No.

MARK NO.

TESTED LEAKAGE _

LEAKAGE LEAKAGE IN OUT (SCF/D)-

(SCF/D).

(SCF/D)-

2CVS*151 X

09-28 93 1.94-

.1. 94 '

94

'2.04.

2CVS*151-1 X

10 11-93 2327.00 2.04 2SSR*A0V129Al X

11 14-93 30.70 0.49 97-1 2SSR*A0V129A2 X

11-14 93, 0.49 0.'49 0.49 2SSR*RV122 X

PARALLEL WITH 2SSR*A0V129A2 2HCS*SOV133B X

09 30-93

'O'49 0.49' 97-2 0.' 49 -

2HCS*SOV134B X

09-30-93 0.49.

0.49 2FPW*761 X

10 11-93 0.49.

'.49 0

99 0.49 2FPU*A0V206 X

10-14 93 0.73

.0.49-2FPW*753 X

10-18-93 0.49-O.49' 101 0.49 2FPW*A0V205 X

10-12-93 0.49 0.49 2 FNC*121 X

09 23 93 26.60 26.60 103 26.60 2TNC*38 X

09 23 93 17.41 17.41_

2FWC*122 X

09-27-93 20.~44 20.44 104 20.44:

1 2FNC*9 X

09 27-93 20.44 20.44 2HCS*SOV133A X

09 30 93

~3.74 3.74' 105 1 3.74 2HCS*SOV134A X

09 30 93 3.10 3.10 2 PAS *SOV105A1 X

09 29-93 0.49

0. 4 9 --

105 2 0.49 2 PAS *SOV105A2-X 09 29-93

' O 49

.0.49 21RS*51 X

09-23-93

'O.48 105 3 "0.48 0.48-2LMS*S2 X

09 23 93

'O.48 0.'48 TOTAL PENETRATION LEAXAGE FOR PAGE.7

~(SCF/D)

'55.75.

Page 6 of 8

I ATIAQ94ENT 4.1C (continued)

EXRIll REFUELING T'IPE C TEST RESULTS CONTAINMENT AS FOUND AS LEFT ASSIGNED PENT VALVE DATE VALVE VALVE PENETRATION

.N O.

MARK NO.

TESTED LEAKAGE LEAKAGE LEAKAGE IN OUT (SCF/D)

(SCF/D)

(SCF/D) i 2 SIS *MOV842 X

09 29-93 0.50 0.49 106 2 SIS *A0V889 X

09 20 93 0.50 0.50 0.-50 j

2 SIS *RV175 X

PARALLEL WITH 2 SIS *A0V689 2FPW*388 X

10 22-93 0.49 0.49 116 0.49 2FPW*A0V221 X

10 02-93 0.49 0.49 2FPW*382 X

10 02 93 0.49 0.49 117 36.93 2FPW*A0V204 X

10 02 93 6.93 36.93 2QSS*267 X

10 28-93 0.49 0.49 i

118 2QSS*SOV100A X

10-28-93 0.49 0.49 0.49 l

2QSS*SOV1008 X

' PARALLEL WITH 2QSS*SOV100A TOTAL PENETRATION LEAKAGE FOR PAGE 8

'(SCF/D) 38.41-l I

TOTAL PENETRATION LEAKAGE PAGE 2 0F (SCF/'))

55.87 TOTAL PENETRATION LEAKAGE PAGE 3 OF (SCF/ D) 5.36 TOTAL PENETRATION LEAKAGE PAGE 4 0F (SCF/D) 64.88 TOTAL PENETRATION LEAKAGE PAGE 5 0F (SCF/D) 14.92

'.'OTAL PENETRATION LEAKAGE PAGE 6 0F (SCF/D) 543.15 TOTAL PENETRATION LEAKAGE PAGE 7 0F (SCF/D) 55.75 TOTAL PENETRATION LEAKAGE PAGE 8 0F (SCF/D) 38.41 TOTAL CONTAINMENT TYPE C LEAKAGE SUM OF PAGES 2 THRU 8 (SCF/D) 778.34 i

l l

Page 7 of 8 l

l

ATIACHENT 4.1C (continued)

FOURIH REFUELDG TWE B AND C TESP RESUIlrS "AS FOUND*

"AS LEFT*

PENERTATION DATE PENETRATION PENETRATION (TEST PROCEDURE)

TESTED LEAKAGE LEAXAGE (SCF/D)

(SCF/D)

ELECTRICAL PENETRATIONS 09 19-93 8.55 8.55 i

(2BVT 1.47.4) l FUEL TRANSFER TUBE FLC.

11 04-93 0.49 0.49 (2BVT 1.47.9)

EQUIPMENT HATCH 11 05 93 0.50 0.49 (2BVT 1.47.9)

EQUIP. HATCH INNER FLC.

11 06 93 0.: 0 0.50 (2BVT 1.47.9)

PERSONNEL AIRLOCK 11 15 93 36.93 136.68 (2BVT 1.47.8)

EMERGENCY AIRLOCK 11-13 93 3.79 15.17 (2BVT 1.47.10)

TOTAL PENETRATION LEAKAGE FOR PAGE 9

.(SCF/D) 161.88 i

TOTAL CONTAINMENT TYPE C LEAKAGE - SUM OF PAGES 2 THRU 8 778.34 SCF/D TOTAL CONTAINMENT TYPE B LEAKAGE - SUM OF PAGE 9 161.88 SCF/D l

TOTAL CONTAINMENT TYPE B & C LEAKAGE SUM OF PAGES 2 THRU 9 940.22 SCP/D i

l i

I i

I Page 8 of 8

ATIACHME2TP 4.1D RXRIH REFUELING IDCAL IDEAGE RATE TEST REPA1RS Emetration No. 2

'Ihe "As-Found" leak test was performed on October 16, 1993. Static NOVATS Testing was performed on valves 20CP*lOV150-1 per NWR 22014 and 2CCP*10V150-2 per ME 22015. Relief valve 20CP*RV102 was removed for In-Service Testing per M4R 17350.

Following ccmpletion of the IOVA'IS Testing arxi reinstallation of the relief valve, the "As-Icft" leak test was performed on October 21, 1993 with acceptable leakage rates measured.

Penetration No. 4 Re "As-Found" leak test was performed on Oct

  • r 9, 1993. Valve 20CP*MOV151-1 was replaced due-to previous Dynamic ICVATS Testing results per NWR 9853.

Static }0 VATS Testing was performed following replacement of the valve per.

MVR 14163.

Following completion of the POVATS testing the "As-Ieft" leak test was performed on October 15, 1993 with an acceptable leakage rate measured.

Penetration Ko. 5

'Ihe "As-Found" leak test was performed on M h v 16, 1993. Static }0 VATS Testing was performed on valves 20CP*10V156-1 per MWR 22103 and 20CP*10V156-2 per MVR 22017. Relief valve 20CP*RV104 was removed for In-Service 'Ibsting per MWR 17351.

Following ocanpletion of the IOVATS 'Ibstirg and reinstallation of the relief valve, the "As-Left" leak test was performed on October 21, 1993 with acceptable leakage rates measured.

Penetration No. 11

'Ihe "As-Found" leak test was performed on October 22, 1993. Static MOVATS Testing was performed on valve 2IAC*lOV133 per MVR 22032. Followiry completion of the NOVATS

Testing, the "As-left", leak test was performed on November 1, 1993 with an acceptable leakage rate measured.

Penetration No. 14

'Ihe "As-Fourd" leak test was performed on September 24, 1993. Relief valve 25WS*RV153 was removed for In-Service Testing per MWR 23615.

Following reinstallation of the relief valve, the "As-Inft" leak test was performed on October 19, 1993 with an acceptable leakage rate measured.

Eenetration No. 19

'Ihe "As-Found" leak test was performed September 27, 1993. Static }OVATS Testing was performed on valves 2CHS*lOV378 per HWR 21970 and 2CHS*MOV381 per MVR 21971. Following completion of the }0 VATS Testirg, the "As-Ieft" leak test was performed on October 18, 1993 with acceptable leakage rates measured.

Page 1 of 7

l l

ATIAQ MENT 4.1D (continued) l IOURm RENEUM IOCAL IMGGE PATE TEST REPAIR i

Penetration No. 20 The "As-Found" leak test was performed October 20, 1993.

During the performance of 2BVP 1.147.3 " Check Valve Lift Test", Check Valve 2 SIS *42 lifted at 0.8 psid which was less than the Acceptance Criteria. M R 24274 was written 1

l to repair the valve.

The soft seat on the valve disc was found to be worn allowing the air to leak by the disc rather than lift the disc. Followiry the replacement of the soft seat, the "As-Inft" leak test was perfarnni on October 30, 1993 with an acceptable leakage rate measured.

Penetration No. 21 The "As-Found" leak test was performed September 21, 1993. Static MOVATS l

Testing was performed on valves 2SWS*}0V155-1 per M R 22030 and 2SWS*M3V155-2 j

per MWR 22031. Relief valve 2SWS*RV155 was removed for In-Service Testing per MR 23539.

Followirg cmpletion of the lOVATS Testing and reinstallation of the relief valve, the "As-Inft" leak test was performed on October 7,1993 with acceptable leakage rates measured.

Penetration No. 25 l

The "As-Found" leak test was performed September 24, 1993.. Relief valve l

2SWS*RV154 was removed for In-Service Testing per MWR 23616..

Following reinstallation of the relief valve, the "As-Inft" leak test was performed on l

October 18, 1993 with an acceptable leakage rate measured.

i Penetration No. 27 The "As-Found" leak test was performed September 21, 1993. Static }OVATS Tusting was performed on valves 2SWS*10V152-1 per MWR 21427 and 2SWS*}OV152-2 per MR 22029.. Relief valve 25WS*RV152 was removed for In-Service hsting per MWR 17354.

Following cmpletion of the loVATS Tbsting arri reinstallation of the relief valve, the "As-left" leak test was performed on October 7, 1993 with acceptable leakage rates measured.

Penetration No. 28 The "As-Found" leak test was performed October 8, 1993. Due to body to 1.u nect leakage detected during plant cperation, the body to bonnet gaskets were replaced for valves 20iS*AOV200A per MR 9680, 2OIS*AOV200B per MWR 10162, 20iS*AOV200C per MNR 9682, and 2OIS*HCV142 per ME 23747.

Followirg replacement of the body to bonnet gaskets,. the "As-Inft" leak test was performed on October 19, 1993 with acceptable leakage rates measured.

l I

Page 2 of 7 i

l ATIAGMENT 4.1D (continued) l IURIH RENELJNG ITAL IEAKAGE RATE TEST REPAIRS l

i l

Penetration No. 38 h "As-Found" leak test was performed October 29, 1993. Due to excessive leakage, MR 24502 was written for valve 2DAS*ADV100A. Debris had damaged the plug stem.

The debris was removed and the pity stem was replaced. Relief Valve 2DAS*RV110 was remved for In-Service Testing per M 17339. Following completion of the repair of 2DAS*AOV100A and reinstallation of relief valvo 2DAS*RV110, the "As-Inft" leak test was performed on November 1, 1993 with acceptable leakage rates measured.

I l

Penetration No. 42 The "As-Found" leak test was performed October 29, 1993. Due to excessive leakage, MR 24502 was written for valve 2DAS*ADV100A. Debris had damaged the plug stem.

The debris was removed ard the plug stem was replaced. Relief Valve 2DAS*RV110 was removed for In-Service Testing per M M 17339. Following l

completion of the repair of 2DAS*AOV100A and reinstallation of relief valve l

2DAS*RV110, the "As-Inft" leak test was performed on November 1, 1993 with acceptable leakage rate measured.

Penetration No. 42 The "As-Found" leak test was performed September 20, 1993. Due to excessive leakage, MM 23335 was written for valve 2SAS*14. The valve seating surfaces were cleaned and the "As-Isft" leak test was performed on September 25, 1993 with an acceptable leakage rate measured.

Penetration No. 45 The "As-Iound" leak test was performed September 20, 1993. Due to excessive leakage, ME 23423 was written for check valve 2RCS*72. The soft seat on the valve disc was found to be damaged and was replaced. Check Valve 2RCS*72 was repaired three additional times during the outage (M E's 23643, 23706, 24255) since durity the performance of 2BVT 1.47.3 " Check Valve Lift 7bst", 2RCS*72 lifted at a pressure less than the Acceptance criteria. The diaphragm for valve 2RCS*AOV519 was replaced for preventive maintenance per M E 16867.

Relief Valve 2RCS*RV100 was removed for In-Service Testing per M M 17332.

Relief Valve 2RCS*RV100 was later removed and repaired per M M 23644 since during the outage excessive leakage was detected during use of the penetration.

Following all these repairs, the "As-Left" leak test was performed an October 23, 1993 for 2RCS*72 and on November 11, 1993 for 2RCS*AOV519 and 2RCS*RV100 with ac ptable leakage rates measured.

Penetration No. 49 The "As-Found" leak test was performed September 25, 1993. The diaphragm for valve 2RCS*AOV101 was replaced for preventive maintenance per MM 16866.

Following the replacement of the diaphragm and several adjustments to the valve actuator, the "As-Isft" leak test was performed on October 31, 1993 with an acceptable leakage rate measured.

Page 3 of 7

ATDCEENT 4.1D (continued)

RXRIH REFUELING IOCAL LEAIGGE RATE TESI REPAIRS Penetration No. 55-1 Se "As-Found" leak test was performed September 28, 1993. Relief Valve 2SSR*RV117 was removed for In-Service 'Ibsting per }ER 17347.

Following reinstallation of the relief valve, the "As-left" leak test was performed on October 18, 1993 with an acceptable leakage rate measured.

Penetration No. 56-1 he "As-Found" leak test was performed September 28, 1993. Air leaks were l

repaired on the actuator for valve 2SSR*AOV102A-1 and 2SSR*ADV102A-2 per IER's 15899 and 15900 due to stroke times trerrling upward. Following completion of these repairs, the "As-Left" leak test was performed on November 5, 1993 with acceptable leakage rates measured.

l i

Penetration No. 56-2

%e "As-Found" leak test was perfomed October 14, 1993. Due to excessive j

l leakage, lER 24006 was written for valve 2SSR*SOV128A-2. Nicks were found in i

the valve disc and seat.

%e disc was replaced and the seat was lapped to i

remove the nicks.

Relief Valve 2SSR*RV120 was removed for In-Service Testing per }ER 17348. New terminal boards, rectifier, and cover gasket were installed i

in valve 2SSR*SOV128A-1 for B2 rcquirements per IER 18190.

Following completion of the repair of 2SSR*SOV128A-1 & 2 and reinstallation of relief j

valve 2SSR*RV120, the "As-left" leak test was performed on November 14, 1993 with acceptable leakage rates measured.

Penetration No. 56-3 he "As-Found" leak test was performed September 28, 1993. Due to excessive packing leakage, }ER 20715 was written for valve 2SSR*AOV100A-2. Relief Valve 2SSR*RV119 was removed for In-Service Testing per IER 24217.

Following completion of the repack of 2SSR*ADV100A-2 and reinstallation of relief valve 2SSR*RV119, the "As-Ieft" leak test was performed on October 29, 1993 with acceptable leakage rates measured.

Penetration No. 57-1

%e "As-Found" leak test was performed September 28, 1993. Relief Valve 2SSR*RV121 was removed for In-Service Testing per }ER 24288.

Following reinstallation of the relief valve, the "As-Ieft" leak test was perfomed on October 29, 1993 with an acceptable leakage rate measured.

Penetration No. 63 he "As-Found" leak test was performed September 22, 1993. Static IOVATS Testing was performed on valve 2QSS*lOV101A per }ER 22003. Relief valve 2QSS*RV101A was removed for In-Service Testing per IER 17345. Following completion of the MOVATS Testing and reinstallation of the relief valve, the "As-Left" leak test was performed on November 12, 1993 with acceptable leakage rates measured.

Page 4 of 7

ATIAGMENT 4.1D (co'tinued) j r00Rm REFUEIJNG IDCAL LEAIG3E RATE TESP REPAIRS 1

I Penetration No. 64 The "As-Found" leak test was performed September 25, 1993. Limit and torque switch adjuAmuns were made to valve 2QSS*MN101B in acco2xlance with DCP 2034 per IHR 14034.

Following coupletion of the limit and torque switch adjustments, the "As-Inft" leak test was performed on October 15, 1993 with an acceptable leakage rate measured.

Penetration No. 87 The "As-Found" leak test was performed September 22, 1993.. Static IOVATS l

l Tbstirg was performed on valve 2HCS*NN117 per MRR 22042. Following cmpletion l

of the IOVATS

Testing, the "As-Left" leak test was performed on l

November 6, 1993 with an acceptable leakage rate measured.

Penetration No. 88 The "As-Found" leak test was performed September 22, 1993. Static IOVATS Ibstirq was performed on valve 2HCS*lOV116 per }MR 22041. Following completion l

of the 10 VATS

Testing, the "As-Left" leak test was performed on l

November 6,1993 with an acceptable leakage rate measured.

Penetration No. 90 1

The "As-Found" leak test was performed September 20, 1993. Due to excessive packirq leakage, MWR 23425 was written for valve 2HVR* MOD 23A. The packing was l

replaced and valves 2HVRIlOD23A and 2HVR* LOD 23B were BARTS Tested per MNR's 22035 and 22036.

Following cmpletion of the repack and BARPS Testing, the "As-Left" leak test was performed on October 2,1993 with an nmaptable leakage rate measured.

Penetration No. 91 The "As-Found" leak test was perfomed September 21, 1993. BARPS Testing was performed on valves 2HVR* LOD 25A and 2HVR* LOD 25B per MWR's 22037 and 22038. ~

Followirg ccupletion of the BARPS Testirg the valves were retested, however due to excessive packirg leakage MWR 23655 was written for valve 2HVR*M]D25A. The packing was replaced.

Followirq coupletion of the repack the valves were retested, however due to excessive seat leakage NWR 24637 was written for valve 2HVR* MOD 25B.

The valve seal ring was replaced..A fourth retest was performed on November 12, 1993 with an acceptable leakage rate measur d.

Eenetration No. 94 The "As-Found" leak test was performed Sqfanber 28, 1993. Due to excessive leakage, MVR 23624 was written for valve 2CVS*151-1.

The valve seat was replaced and the "As-Inft" leak test was performed on October 11, 1993 with an acceptable leakage rate measured.

Page 5 of 7

e f.

ATIACHENT 4.1D (continued)

FIXHUH REFUELING IIX:AL LENKAGE RATE TEST REPAIRS Penetration No. 97-1 The "As-Found" leak test was performed Och 14, 1993. Due to low flow suspected through valve 2SSR*SOV129A-1, MR 23319 was written to inspect the valve.

It was found that a soft seated disc was installed in the valve which was not suitable for the valve's application. 7he seat disc was replaced with a hard seated disc. Relief Valve 2SSR*RV122 was removed for In-Service Testing per MRR 24220. New terminal boards, rectifier, and cover gasket were installed in valve 2SSR*SOV129A-1 for EQ requimunutus per ME 18162.

Following completion of the repair of 2SSR*SOV129A-1 & 2 and reirstallation of relief j

l valve 2SSR*RV122, the "As-Isft" leak test was performed on November 14, 1993 l

with acceptable leakage rates measured.

l Penetration No. 99 The "As-Found" leak test was performed October 11, 1993.- During inspection of I

the Containment Hose Reels it was discovered that the Containment Fire l

Protection Hose Reel Header would not der.essurize even with valve 2FPW*AOV206 l

closed.

MWR 23922 was written to inspect the preload on the actuator for 2FPW*A0V206.

The preload was found to be set too low to hold the valve closed i

against the Containment Hose Reel Header Pressure. Following the adjustment of I

the preload, the "As-Inft" leak test was performed on October 14, 1993 with an acceptable leakage rate measured.

Penetration No. 101 l

The "As-Found" leak test was performed October 12, 1993.

During the performance of 2BVT 1.47.3 " Check Valve Lift Test", C. heck Valve 2FPW*753 lifted at 0.2 psid which was less than the Acceptance Criteria. MWR 16929 was previously written to inspect the valve for routine maintenance. The soft seat on the valve disc was found to be worn allowing the air to leak by the disc rather than lift the disc.

Following the replacement of the soft seat, the "As-Isft" leak test was performed on October 18, 1993 with an acceptable leakage rate measured.

Penetration No. 106 The "As-Found" leak test was performed September 20, 1993. Static M3 VATS Testing was performed on valve 2 SIS *f0VB42 per MR 22098. Following completion of the M3 VATS Tbsting, the "As-Left" leak test was performed on September 29, 1993 with an acceptable leakage rate measured.

Page 6 of 7

4 ATD4HENT 4.1D (continued) 4 FOURIH REFUELING IDCAL LEAIGGE RATE TESP REPAIRS Penetration No. 116

'Ihe "As-Fcund" leak test was performed Ocheer 2,1993. During the performance of 2BVf 1.47.3 " Check Valve Lift Test", Check Valve 2FPW*388 lifted at 0.3 psid which was less than the Acceptance Criteria ~. M4R 23707 was written to repair the valve. Imperfections were found in the valve seating area allowing the air to leak by the disc rather than lift the disc. 'Ibe imperfections were renoved and a second lift test was performed with an unacceptable lift pressure l

measured.

M4R 23898 was written to repair the valve. Numerous repair attenpts and retests were performed until the vendar discovered that the valve disc was not centered on the valve seat. Shims were installed on.the valve swing arms to center the disc.

Fbilowiry this repair, an acceptable lift test was performed and the "As-Inft" leak test was perfacmed on Octe**r 22, 1993 with an acceptable leakage rate also manaured.-

-i i

I Page 7 of 7

,=

ATIAQ EENT 4.1E e

'IHIRD AND FOURIH FUEL CYCLE IDCAL IDFME RATE TEST DNIA I.

'Ihird Riel Cycle IIRT Data i

A.

Type B 'Ibsts 1.

Airlock Total Volume Type B Tests a.

Fuiunel Airlock [2PHS* PAL 1)) (4-2-91) 96.90 SCF/D Cw.tective Actir.( )

Inner door o-ring was replaced per Maintenance Work Request 910468.

b.

Bauipment Hatd1 Airlock [2PHS*IAL1] (4-3-91) 0.51 SCP/D Cbrrective Acticn(s)

None c.

Personnel Airlock [2PHS* PAL 1] (9-24-91) 48.54 SCF/D Cw.tective Action (s)

None i

d.

Equipnent Hatch Airlock [2PHS*EAL1] (9-26-91) - 8.01 SCP/D Cw.tective Action (s)

None B.

Type C Tests 1.

Penetration No. 97-1 [2SSR*RV122] (11-27-90) 0.49 SCP/D Cw.tective Action (s)

Relief valve was leaking by.

'Ihe relief valve was replaced with a new i

relief valve per Maintenance Work l

Request 906593.

l 2.

Penetration No. 55-1 (2SSR*RV117] (5-21-91) 0.48 SCF/D i

l Corrective Action (s)

Relief Valve was leaking by.

'Ihc relief valve was repaired per Maintenance Work Request 0913.

3.

Penetration No. 56-2 [2SSR*RV120] (10-9-91) 0.49 SCF/D Corrective Action (s)

Relief valve was 3eaking by.

The i

Relief Valve was repaired per l

Maintenance Work Request 2730.

l Page 1 of 2

9 l

c',,

ATIACHENT 4.1E (continued)

THIRD AND FOURIH FUEL CYCLE IDCAL LEAKAGE RATE TEST DATA i

II. Fourth Ebel Cycle LIRT Data A.

Type B Tests 1.

Airlock Total Volume Type B Tests a.

Peu.-ual Airlock [2PHS* PAL 1] ' (10-20-92).

8.73 SCF/D Corrective Action (s)

None I

b.

Equipnent Hatch Airlock [2PHS*EAL1] (10-21-92) 0.50 SCP/D.

Cvu ective Action (s)

None c.

Ptu.muel Airlock [2PHS* PAL 1] (3-24-93) 36.93 SCP/D Corrective Action (s) '

None d.

Bquipment Hatch Airlock [2PHS*EAL1] (3-25-93) 3.79 SCF/D Corrective Action (s)

None-B.

Type C Tests 1.

Penetration No. 56-1 [2SSR*RV118] (2-19-93)

O'.49 SCF/D cvu active Action (s)

Relief valve was leaking _by.-

The-relief valve was-replaced with a new relief valve per Maintenance Work Request 10907.

2.

Penetration No. 56-1 [2SSR*RV118]-(6-18-93)

O.49.SCP/D Corrective Action (s)

Relief valve was_ leaking by.

The' relief ~ valve was' replaced 'with a new.

relief valve 'per Maintenance. Work Request 20672.

NorE:

BVPS #2 Technical Specifications limit Type B leakage of each l

airlock to 5% La (347 SCP/D).

Total Type _ B and-C leakage (excluding airlocks) is adm4nistratively_ limited to 50% Ia to -

account for airlock retests.

Page 2 of 2 l

_