Text
>
VERMONT YAN KME NUCLEAR POWER CORPORATION SEVENTY SEVEN GROVE STREET 2.C.2.1 FVY 82-47 RUTLAND, VERMONT 05701 REPLY TO:
ENGINEERING OFFICE April 30,.1982 1671 WORCESTER ROAD FRAMINGH AM, M ASSACH USETTS ol7ot TELEPHONE 817 872 8100 United States Nuclear Regulatory Commission di 4
Washington, D. C. 20555 N
~
g Attention:
Of fice of Nuclear Reactor Regulation p [#
]
Mr. D. B. Va ssa llo, Chief
[
fj en,-
]
'./
Operating Reactors Branch N f7llg#& [NL.
Division of Licensing g
of 4
References:
(a) License No. DPR-28 (Docket No. 50-271)
O h
(b) Letter, USNRC to VYNPC, dated March 17, 1982
/
g (c) Letter, VYNPC to USNRC, FVY 82-17, dated February 82 4
(d) Letter, USNRC to VYNPC, dated January 15, 1982 (e) Letter, VYNPC to USNRC, FVY 81-161, dated November 16, 1981 (f) Letter, VYNPC to USNRC, FVY 81-131, dated September 4, 1981 (g) Letter, VYNPC to USNRC, FVY 80-1707 dated December 15, 1980
Subject:
Environmental Qualification of Safety-Related Electrical Equipment
Dear Sir:
In response to your letter, dated March 17, 1982, we are providing you with additional information relative to environmental qualification of equipment associated with the NUREG-0737 sections addressed below.
IIE4.1 Dedicated Hydrogen Penetrations:
The equipment installed which addresses this requirement is that which is listed on the Master List under Containment Atmosphere Dilution System.
Documentation for equipment on CAD worksheets was submitted in Reference (c).
IIK3.13 Separation of HPCI and RCIC System Initiation Levels, Analysis, and Implementation:
No changes were made relative to separation of HPCI/RCIC initiation levels, based on the BWR Owners Group position.
IIK3.15 Modify Break-Detection Logic to Prevent Spurious Isolation of HPCI and RCIC:
8 Relative to HPCI/RCIC steam line isolation, changes were made to electrical equipment.
However, in the RCIC System, the f Q changes involved the addition of timers in the Control Room which is a mild environment; and in the HPCI System, the vendor 8205040664 820430 PDR ADOCK 05000271 P
e United States Nuclear Regulatory Commission April 30, 1982
.}
' Attention:
Mr. L D. B. Vassallo -
Page 2-modified an existing. component in the electronic govern'or,'but this component is not required to operate in a_ harsh environment.'
IIK3.19 Interlock on Recirculation Pump Loops:
The recirculation. pump interlock requirement does not apply to Vermont Yankee.
IIK3.21 Restart of Chre Spray and LPCI: Systems:
Relative to core spray ~ and LPCI auto restart,; no changes were -
made at Vermont Yankee based on the BWR Owners Group position.
~
11K3.27 Provide Common Reference Level'for' Vessel Level Instrumentation:
To provide a common reference for reactor water level, only the meter indicator scales were changed. The associated
. safety-related level transmitters, which were not modified for TMI, are on Worksheet PAM-5, and documentation was submitted in Reference (e)
We trust 'this information is acceptable to you; however, should you have -
any questions, please contact us.
Very - t ruly yours, j
VERMONT YANKEE NUCLEAR POWER CORPORATION.
,. D.
tnL01U
. :. Sinclair B
Licensing. Engineer JBS : dad -
cc:
Mr. Cyril J. Crane Franklin Research Center q
The Parkway at Twentieth Street Philadelphia, Pennsylvania 19103
.