ML20062M341

From kanterella
Jump to navigation Jump to search
Application for Amend to License DPR-59,revising TS to Clarify SRs for Radiation Monitoring Recorders Specified in LCO Spec 3.1.a of RETS
ML20062M341
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 12/29/1993
From: Ralph Beedle
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
Shared Package
ML20062M340 List:
References
NUDOCS 9401060453
Download: ML20062M341 (1)


Text

_

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION in the matter of

)

NEW YORK POWER AUTHORITY

)

Docket No. 50-333 James A. FitzPatrick Nuclear Power Plant

)

APPLICATION FOR AMENDMENT TO OPERATING LICENSE The New York Power Authority requests an amendment to the Technical Specifications contained in Appendix B to Facility Operating License DPR-59 for the James A. FitzPatrick Nuclear Power Plant. This application is filed in accordance with Section 10 CFR 50.90 of the Nuclear Regulatory Commission's regulation.

This application for an amendment to the James A. FitzPatrick Technical Specifications, Appendix B, revises Surveillance Requirement 3.1.a and Table 3.10-2. The existing Surveillance Requirement in Specification 3.1.a, which references Table 3.10-2, requires the performance of instrument checks, tests, and calibrations to assure the operability of specific gaseous effluent radiation monitors. It does not require any surveillances for the associated data recorders. However, LCO 3.1.a specifically states that "... pathways shall be monitored and recorded..." which requires the recorders to be operable for the gaseous effluent monitoring system to be considered cperable. The proposed changes to the Radiological Effluent Technical Specifications (RETS) add the radiation monitor recorders to the Surveillance Requirement and Table 3.10-2 for the gaseous effluent monitoring system. This will provide the surveillance requirements for the data recorders.

The proposed change to the RETS is Attachment I to this Application for Amendment to the Operating License. The Safety Evaluation for the proposed change is included as Attachment II. Attachment tilis a markup of the affected pages.

New York Power Authority r

/

n+.

hdC 7

Rsich E. Bee e Executive Vi e P esident

'N Nuclear Ge ration s

STATE OF NEW YORK COUNTY OF WESTC: GTER Subscribed and sworn to before me this y day o' dlae,2h1993.

KATHLEEN D. GALLAGHER Notary Pubhc, State of NewYork 1

No. 5004481 3 },/zT/hw _

ls/n j

Ouelifiedin Westchester Coud Commission Expires Nov. % 1W, Notary Public 9401060453 931229 PDR ADOCK 05000333 P