PUBLIC SERVICE sEAam swa Engineering Office:

Companyof NewHampshre 1671 Worcester Road Frominoham. Massachusetts 01701 (617) - 872-8100 August 17, 1982 SBN-310 T.F. B 7.1.2 United States Nuclear Regulatory Commission Washington, D. C. 20555 Attention:

Mr. Frank J. Miraglia, Chief Licensing Branch No. 3 Divisicn of Licensing Re fere nces :

(a) Construction Permit CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) USNFC Letter, dated March 1, 1982, " Request for Additional Information," F. J. Miraglia to W. C. Tallman (c) PSNH Letter, dated April 21, 1982, " Response to 210 Series RAIs; (Mechanical Engineering Branch)," J. DeVincentis to F. J. Miraglia

Subject:

ADLPIPE Benchmark, RAI 210.28; (Mechanical Engineering Branch)

Dear Sir:

In our response to RAI 210.28, submitted in Reference (b), we committed to benchmarking the United Engineers' version of the ADLPIPE computer code against Problem #4 from NUREG/CR-1677.

The enclosed United Engineers' Report (Problem #4, Piping Benchmark Problems, NUREC/CR-1677, BNL-NUREG-51267, Vol. 1) provides verification of the United Engineers version of ADLPIPE.

The results obtained for Problem #4 by UE&C's in-house version of ADLFIPE were compared with the results dc,cumented in NUREG/CR-1677. Parameters included in the comparisons are:

o Frequencies o

Fesultant displacement o

Resultant elemental forces and moments o

Resultant elemental stresses o

Resultant support reactions All items listed above demonstrated excellent agreement with the NUREC results. For convenience in future comparisons, and for documentation 8208190075 820817

/

PDR ADOCK 05000443

{

A PDR I3 h

i i t.

kitedStatesKuclearRegulatoryComeission August 17, 1982 2

I

,) ' Attention:

Mr. Frank J. Miraglia Page 2 purposes, selected items from the above list have been tabulated f.n the summary sheets of the enclosed document.

'Very truly yours, t

L eYANKEE ATOMIC ELECThIC COMPANY Yk J. DeVincentis j

Project Manager Enclosure t

t I

i l

l A

i 4

.,..~

l.

i l

l 5

h

,i I

l l

i I

e t

-c --..

-. ~.

y-r,

-