ML20062K484

From kanterella
Jump to navigation Jump to search
Forwards Resurveillance Rept on Three-Yr Surveillance Tendons for Containment Post-Tensioning Sys, Addendum to Three-Yr Tendon Surveillance Rept
ML20062K484
Person / Time
Site: Farley 
Issue date: 08/11/1982
From: Kingsley O
ALABAMA POWER CO.
To: Reeves E
Office of Nuclear Reactor Regulation
Shared Package
ML20062K487 List:
References
NT-82-2443, NUDOCS 8208170225
Download: ML20062K484 (1)


Text

At:b:m3 Powsr Company 60-][8 600 North 18th Strat a

W Post Offica Box 2641 Birmingham, Alabama 35291 Telephone 205 250-1000 NT-82-2443 L

Alabama Power ItW' SOUIhtTO C

  • Clf C 5 VS!L9D I

August 11, 1982 Mr. E. A. Reeves Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 J. M. Farley Nuclear Plant - Unit 1 Resurve111ance Report on Three Year Surveillance Tendons

Dear Mr. Reeves:

Per your discussion with D. M. Varner and S. T. Burns, Jr. on August 9,1982, Alabama Power Company herewith submits seven (7) additional copies of the subject report for your review.

Extra copies are a ailable upon request.

The Five Year Containment Tendon Surveillance Reports transmitted to the NRC on July 7,1982 were for information purposes only and were not required to be submitted pursuant to the Unit 1 Technical Specifications paragraph 4.6.1.6.4.

If you have any questions, please advise.

Your y,

/- >

. r

0. D. Kingsley 3

Manager N-ear i

ering and Technica uppo STB:bs Attachments cc:

Mr. W. H. Bradford (w/o attachment)

Mr. J. J. Lenahan (w/o attachment)

File: 91T-37 (w/o attachment) l col y

, o y 8208170225 820811 PDR ADOCK 05000348 P

PDR