Final Deficiency Rept Re Nonconforming Rockbestos Cable Delivered to Facility.Samples from All Suspect Cable Reels Returned to Manufacturer for Testing Against Bechtel Specs. Deficiency Concerns Physical Properties of Jacket Only
ML20062K232
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 08/09/1982
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8208170094
Download: ML20062K232 (2)


Text

'

CTANSAS GAS AND ELECTRIC C)MPANY f *1E E LE CT F#C CCMPANY GLENN L MOESTER vK s res tos e.f owcteam August 9, 1982 Mr. W.C. Seidle, Chief Reactor Projects Branch 2 U.S. Nuclear Regulatory Commission, I

g Region IV f

Y 611 Ryan Plaza Drive, Suite 1000 j

1 Mf 7 Arlington, Texas 76011 KMLNRC 82-232 Re:

Docket No. STN 50-482 Subj : Final 10CFR50.55(e) Report Nonconforming Rockbestos Cable

Dear Mr. Seidle :

This letter is the final report on nonconforming Rockbestos cable delivered to the Wolf Creek Generating Station. Kansas Gas and Electric Company (KG&E) and the Architect / Engineer have completed the evaluation of the cable and have concluded that this matter is not reportable under the requirements of 10CFR50.55(e).

Samples from all of the suspect cable reels were returned to the man-ufacturer for testing against the requirements of Bechtel specification 10466-E-057.

This specification is more stringent than Standards set by the cable industry. For example, Insulated Cable Engineers Association (ICEA) Standard S-19-81, paragraph 4.13.4, allows a minimum cable jacket tensile strength of 1500 psi and percentage elongation af ter air and oil aging of 50 and 60 percent respectively. Specification 10466-E-057, paragraph 6.4.4.2, requires 1800 psi tensile strength and elongation after air and oil aging of 60 and 60 percent respectively.

One reel of 7/C #14AWG cable, designated for safety-related applications, was rejected because percent elongation for the outer jacket was 53% af ter air oven aging. This met ICEA Standards, but the cable was rejected be-cause it did not meet specification 10466-E-057 criteria. All other suspect reels met the acceptance criteria.

The deficiency in the rejected cable was related only to the physical properties of the jacket. Environmental qualification testing was performed on individual unjacketed control cables and the insulated singles success-

'k gg8Si?88NB88$g

/[

201 N. Market - Wictuta, Kansas - Mail Address: PO. Box 208 I Wichsta, Kansas 67201 - Telephone: Area Code (316) 261-6451

Mr. W.C. Seidle KMLNRC 82-232 August 9, 1982 fully passed testing per IEEE-323 and -383.

Therefore, the lack of an overall jacket would not affect the ability of the cable to perform its safety-related electrical functions.

The one reel of 7/C #14AWG cable was returned to the manufacturer because, from a commercial standpoint, it did not meet specification lO466-E-057 prior to shipment to the Wolf Creek job site. However, inadvertent use of the cable would not have compromised the safety of the Wolf Creek Generating Station.

Documentation of the cable tests and engineering evaluation are available for review. If you require additional information, please contact me or Mr. Otto Maynard of my staff.

Yours very truly,