ML20062K162

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re Essential Svc Water Pipe Support Embedded Plate Stud Failure.Deficiency Determined Not Reportable Under 10CFR50.55(e). Essential Svc Water Sys Pump Restraint Embed Rept Encl
ML20062K162
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 08/10/1982
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20062K167 List:
References
10CFR-050.55E, 10CFR-50.55E, KMLNRC-82-233, NUDOCS 8208170067
Download: ML20062K162 (1)


Text

e e

t 9

KANSAS GAS AND ELECTRIC COMPANY T HE F L E C TRC Cf #APAN f OLENN L MOESTER vs<fPoE00a%v sevctgae August 10, 1982 Mr. W.C. Eoidle, Chief U.S. Nuclear Regulatory Commission,

%@}] p g %

Reactor Projects Branch 2 Region IV 611 Ryan Plaza Drive, Suite 1000 Si AUG I 21982 l

Arlington, Texas 76011 l ljj t

KMLNRC 82-233 Re:

Docket No. STN 50-482 Subj: Final 10CFR50.55(e) Report - Essential Service Water Pipe Support Embedded Plate Stud Failure

Dear Mr. Seidle:

This letter is the final report on the Essential Service Water Pipe Support Embedded Plate. Kansas Gas and Electric Company and the Architect / Engineer have completed the evaluation of the embedded plate and concluded that, had the deficiency not been detected, the safety of the plant would not have been adversely a f fected. Therefore, this matter is not reportable under the requirements of 10CFR50.55(e).

A copy of the Architect / Engineer's final report on this matter is attached.

It provides a detailed summary of the testing and engineering evaluation of the embedded plate. Please note that Appendices I, II and III of the report are voluminous and have therefore been omitted in this transmittal. However, complete documentation, including the above-mentioned Appendices, are available for your review.

If you require additional information on this matter, please contact me or Mr. Otto Maynard of my staff.

Yours very truly,

)-

-ffjy f U

GLK:bb Attach cc: Mr. Thomas Vandel, w/a

'y 8208170067 820810 PDR ADOCK 05000482 S

PDR 201 N. Market ~ Wichita, Kansas - Mail Address: PO. Box 208 I Wichita. Kansas 67201 - Telephone: Area Code (316) 261-6451