ML20062H174

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info to Confirm Presence or Absence of Potentially Hazardous Geologic Structure within 5 Miles of Site
ML20062H174
Person / Time
Site: Skagit
Issue date: 08/04/1982
From: Novak T
Office of Nuclear Reactor Regulation
To: Myers R
PUGET SOUND POWER & LIGHT CO.
References
NUDOCS 8208130329
Download: ML20062H174 (3)


Text

7 M

g DISTRIBUTION:

c Docket.Nos. STN,50-522/523L LB #4 r/f DEisenhut EAdensam bec: TERA Docket flos: STil 50-522 CMoon NRC/PDR and ST!1 50-523 MDuncan Local /PDR l'r. Robert V. l'yers SHanauer NSIC Vice President, General Resources RTedesco TIC Puget Sound Power & Light Company RVo11mer ACRS (16)

Puget Power Building JKramer Bellevue, Washington 98009 RMa ttson RHartfiel d

Dear Mr. flyers:

0 ELD 018E

Subject:

Request for Additional Infomation - Skagit/Hanford fluclear Project On June 8,1982, we forUarded a request for additional infomation and a staff position (RSP 231.5) relating to the need for a definitive integrated study within five niles of the site.

In a meeting with the i!RC staff on July 8 and 9,1982, your representatives provided an extensive presentation and discussion of the results of that study. Although the staff did not reach a conclusion on the acceptataity of that study,it agreed to advise you of its conclusions by about July 16, 1982. On July 16, 1982, the staff telephoned your representatives to advise that the staff had detemined that sone additional investigations are required in one area for which there is not sufficient infomation to confim the presence or absence of a potentially hazardous geologic structure. Our request for additional infomation is attached.

Your representatives met with the staff on July 21, 1982, to present a proposed progran for obtaining the additional information outlined in the enclosure.

Although staf f connents indicated a potential for extension of the proposed programs, depending on the outcore of the investigation, the staff agreed that the progran as proposed was generally responsive to the infomation request.

As stated in the nceting, the staff will be available for review of intemediat.e results throughout the investigation.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, Thonas M. flovak, Assistant Director for Licensing 8208130329 820804 vision of Ucensing PDR ADOCK 05000522 A

PDR

Enclosure:

As sta ted

?

..La;.atgta..s..x)t;.B 4.{,,

A.:DL

..........$....".?"."...?

.".?...........o cc:

omm d,,,,,.,

.o mo

.C o

....m#can....

..tmemam.....ar ca.....

. u m s2........vhaa........2gp2.........n...t

..gp82 em OFFICIAL RECORD COPY une i,.i_m.,eo NRC FORM 318 (10-80) NRCM 024o

SKAGIT/HANFORD Mr. Robert V. Myers Vice President, General Resources Puget Sound Power and Light Company Puget Power Building Be71evue, Washington 98009 cc:

Mr. M. V. Stimac, Manager Ralph Cavanagh, Esq.

Licensing & Regulation Natural Resources Defense Northwest Energy Services Company Council, Inc.

P.O. Box 1090 25 Kearny Street Kirkland, Washington 98033

-San Francisco, California 94108 Mr. F. Theodore Thomsen Mr. Russell Jim Perkins, Coie, Stone, Olsen Tribal Councilman

& Williams Consolidated Tribes and Bands 1900 Washington Building Yakima Indian Nation Seattle, Washington 98101 P.O. Box 151 Toppenish, Washington 98948 Mr. Robert Lowenstein Lowenstein, Newman, Reis Robert Engelken, Regional Administrator

& Axelrad U.S. Nuclear Regulatory Commission, Suite 1214 Region V 1025 Connecticut Avenue, N.W.

1450 Maria Lane, Suite 210 Washington, D. C.

20036 Walnut Creek, California 94596 Mr. Ll oyd K. Marbet Mr. Frank Spangenberg c/o Forelaws on Board Assistant Project Manager - Nuclear 19142 South Bakers Ferry Road Northwest Energy Services Company Boring, Oregon 97009 P.O. Box 1090 l

Kirkland, Washington 98033 Mr. Nicholas D. Lewis, Chairman Energy Facility Site Evaluation Terence L. Thatcher l

Pacific Northwest Resources Council l

Mail Stop PY-11 Center Olympia, Washington 98504 Law Center, 1101 Kincaid Eugene, Oregon 97403 l

Honorable Richard Sandvik l

Department of Justice 500 Pacific Building 520 Southwest Yamhill Portland, Oregon 97204 Coalition for Safe Power l

Governor Building - Suite 527 408 S.W. Second Avenue Portland, Oregon 97204 i

l L.

SKAGIT/HANFORD NUCLEAR PROJECT UNITS 1 AND 2 PUGET SOUND POWER AND LIGHT COMPANY DOCKET N05. 50-522 AND 50-523 231.14 The applicant will conduct a core boring program of sufficient scope to determine if the May Junction monocline is fault controlled.

If fault controlled, this program should provide sufficient new subsurface evidence demonstrating that the fault is not capable.

This may include other subsurface techniques and information to supplement the core borings.

This program should be of sufficient scope to define the attitude, sense of movement and age of last movement of the fault and be designed to carefully recover and define the overlying formations in this area.

231.15 Provide a table and/or other device showing the relationship between the various site area lithologies and velocities (downhole, crosshole and refraction).

1 1

l l

I

,..m

~

_ _ -.,