ML20062H120

From kanterella
Jump to navigation Jump to search
Forwards Notification of NRC Evaluation of New Info Re Flow Blockage Model for ECCS to Determine Design Conformance
ML20062H120
Person / Time
Site: 05000471
Issue date: 04/02/1979
From: Beverly Smith
NRC OFFICE OF THE EXECUTIVE LEGAL DIRECTOR (OELD)
To: Callihan A, Cole R, Luton E
Atomic Safety and Licensing Board Panel, UNION CARBIDE CORP.
References
NUDOCS 7905070131
Download: ML20062H120 (1)


Text

. . - ,

e.

9

, . . fL . . . . . . . . --

4 M (* '

UNITED STATES

['r '

'S NUCLEAR REGULATORY COMMisslON

[, , WASHINGTON, D. C. 20555

% 2 ,

?

%,; , / Apyil 2,1979 NP.C PIIDLIC DCCJMENT ROOM Edward Luton..Esq. .

Dr. A. Dixon Callihan-Atomic Safety and Licensing Board Union Carbide Corporation U.S. Nuclear Regulatory Commission P. O. Box Y Washington, D.C. 20555 Oak Ridge, Tennessee 37830  ;

Dr. Richard F. Cole , e -;; .

Atomic Safety and Licensing Board -~

U.S. Nuclear Regulatory Commission i ' ' % ' <. -g' " y,'s

.' ei

-i

  • In the Matter of ~

BOSTON EDISON C0ff ' , E AL.

(Pilgrim Nuclear Generat ng Stat'i n, Unit 2)

Docket No. 50-471 -

Gentlemen: -

This letter is to notify you that the Staff is evaluating new infonnation relating to Combustion Engineering's flow blockage model for the Pilgrim Unit 2 Emergency Core Cooling System (ECCS). This model is being reviewed to determine Pilgrim Unit 2's ECCS design conformance to the requirements of Appendix K and 10 CFR 550.46. I will forward to you the Staff's evaluation of this information when it is ccmpleted.

Sincerely, , ,

.hq f L

Barry H. Smitn Counsel for NRC Staff cc: See Pilgrim Service List .

7905070/3i. G

.