[r gl1 Nuclear o* "o-

'4$

"ai ioa "o-

'1 Budget Technical Data Report Activity No.

315302 Page 1 of 26 Project:

Department /Section 5300 OYSTER CREEK Revision Date 2-/-87 Decurent

Title:

STATISTICAL ANALYSIS OF ORYWELL THICKNESS DATA OrigineterSignature Date Approval (s) Signature Date

$ft>Y

/ ~.23 -84 b0 S llY21

(

, onwn s

lh.k V L4 J :>

l-M-R K

Approval for External Distribution Date _

Does this TDR include recommendation (s)?

Yes 1 No If yes, TFWR/TR#

Distribution Abstract:

J. D. Abramovici Statement of Problem F. P. Barbieri G. R. Capodanno The design of the carbon steel drywell includes a sand D. W. Covill bed which is located around the outside circumference D. G. Jerko between elevations B' 1/4" and 12'-3".

Leakage M. W. Laggart was observed from the sand bed drains during the 1980, L. C. Lanese 1983 and 1986 refueling outages indicating that water S. D. Leshnoff had intruded into the annular region between the J. A. Martin drywell shell and the concrete shield wall.

J. P. Moore M. A. Orski A long term monitoring program was established in 1986 S. C. Tumminelli

, to take Ultrasonic Thickness (UT) measurements at rep-M. O. Sanfor3 resentative locations on the drywell shell to determine D. G. Slear the corrosion rate and monitor it over time.

The R. W. Keaten initial program included six locations in the sand bed region.

The program was expanded in 1987 to include measurements at higher elevations.

(For Additional Space Use Side 2)

This is a report of work conducted by an individual (s) for use by GPU Nuclear Corporation. Neither GPU Nuclear Corporation nor the authors of the report warrant that the report is complete or accurate.

Nothing contained in the report establishes company policy or constitutes a commitment by GPU Nuclear Corporation.

  • Abstract only l

9012030051 N1126 PDR ADOCK O*.000219 P

PDC

F d5s et Continuation TDR No.

948 Revision No.

1 A cathodic protection system is being installed in selected regions of the sand bed to minimize corrosion of the drywell.

The long term monitoring program was further expanded in 1988 to monitor the effectiveness of the cathodic protection system and to monitor additional sand bed regions not covered by cathodic protection.

A critical part of the long term program is the statistical analysis of the UT measurements to determine the corrosion rate at each location. This report documents the assumptions, methods, and results of the statistical analyses of UT measurements taken through December 31, 1988.

Summary of Key Results Bay Area Location Corrosion Rate **

Mean Thickness ***

11A Sand Bed Not significant 908.6 15.0 mils 11C Sand Bed Indeterminable 916.6 110.4 mils 17D Sand Bed

-27.6 16.1 mpy 864.8 16.8 mils 19A Sand Bed

-23.7 14.3 mpy 837.9 14.8 mils 19B Sand Bed

-29.2 10.5 mpy 856.5 10.5 mils l'90 Sand Bed

-25.9 14.1 mpy 860.9 14.0 mils 90 Sand Bed Indeterminable

  • 1021.4 19.7 mils 13A Sand Bed Not significant*

905.3 110.1 mils 150 Sand Bed possible*

1056.0 19.1 mils 17A Sand Bed Indeterminable' 957.4 19.2 mils 5

51' Elev.

-4.3 10.03 mpy 750.0 10.02 mils 9

87' Elev.

Not significant 620.3

+1.0 mils 13 87' Elev.

Not significant 635.6 10.7 mils 15 87' Elev.

Not significant 634.8 10.7 mils 17D Trench Not significant*

981.2 16.7 mils 17/19 Frame Cutout Indeterminable

  • 981.7 14.4 mils 1D Sand Bed Indeterminable
  • 1114.7 +30.6 mils

~

3D Sand Bed Hot significant*

1177.7 15.6 mils SD Sand Bed Not significant*

1174.0 12.2 mils 7D Sand Bed possible*

1135.1 14.9 mils 9A Sand Bed Indeterminable

  • 1154.6 14.8 mils 13C Sand Bed Hot significant*

1147.4 13.7 mils 13D Sand Bed Not significant*

962.1 f22.3 mils 15A Sand Bed Not significant*

1120.0 112.6 mils one data point in Bay 19A and one data point in Bay 5 Elev. 51' fell outside l

the 99% confidence interval and thut are statistically different from the mean thickness.

  • Based on limited data.

See text for interpretation.

l

    • Mean corrosion rate in mils per year i standard errer of the mean

"* Current mean thickness in mils 1 standard error of the mean page la N 00308 (02 88)

c 1

[r gv1 Nuclear

= =x = "o-TDR 948 TITLE STATISTICAL ANALYSIS CT DRYh* ELL THICYSESS DATA REV

SUMMARY

OF CHANGE APPROVAL DATE

/gh 1

Corrected outage numbers on pages 3 and 5 1-30-89 (two places).

Deleted redundant discussion of Bay 15D on pages 12, 19, 25 and 26.

ll38l39 4

{'

i I

lb

\\

= _ _

TDR 948 Rov. O Page 2 of 26 TABLE OF CONTENTS Sections Page 1.0 INTRODbCTION 3

1.1 Background

3 1.2 Statistical Inferences 4

2.0 METHODS 5

2.1 Selection of Areas to be Monitored 5

2.2 UT Measurements 6

2.3 Data at Plug Locations 6

2.4 Bases for Statistical Analysis of 6"x6" Grid Data 7

2.5 Analysis of Two 6"x6" Grid Data Sets 9

2.6 Analysis of Single 6"x6" Grid Data Set 10 2.7 Analysis of Single 7-Point Data Set 11 2.8 Evaluation of Drywell Mean Thickness 13

3.0 REFERENCES

15 4.0 EVALUATION OF DATA THROUGH 12/31/88 15 4.1 Results for 6"x6" Grids in Sand Bed Region at Original Locations 15 4.2 Results for 6"x6" Grids in Sand Bed Region at New Locations 18 4.3 Results for 6"x6" Grids at Upper Elevations 20 4.4 Results for !!ultiple 6"x6" Grids in Trench 22 4.5 Results for 6" Strips in Sand Bed Region 23 4.0 Sumary of Conclusions 25 l

1 TDR 948 R v. 1 i

page 3 of 26

1.0 INTRODUCTION

1

1.1 Background

)

The design of the carbon steel drywell includes a sand bed which is located around the outside circumference between elevations B'-11-1/4" and 12'-3".

Leakage was observed from the sand bed drains during the 1980, 1983 and 1986 refueling outages indicating

]

that water had intruded into the annular region between the drywell j

shell and the concrete shield wall.

The drywell shell was inspected in 1986 during the 11R outage to determine if corrosion was occurring.

The inspection methods, results and conclusions are documented in Ref. 3.1, 3.2, and 3.3.

Ar a result of these inspections it was concluded that a long term monitoring program would be established.

This program includes repetitive Ultrasonic Thickness (UT) measurements in the sand bed region at a nominal elevation of 11'-3" in bays 11A, 11C, 17D, 19A, 19B, and 19C.

The continued presence of water in the sand bed raised concerns of potential corrosion at higher elevations. Therefore, UT measurements were taken at the 51' and 87' elevations in November 1987 during the 11M outage. As a r6sult of these inspections, repetitive measurements in Bay 5 at elevation 51' and in Bays 9, 13 and 15 at the 87' elevation were added to the long term monitoring program to confirm that corrosion is not occurring at these higher elevations, t cathodic protection system is being installed in selected regions ot' the sand bed during the 12R outage to minimize corrosion of the dry' ell. The long term monitoring program was also expanded during the.2R ottage to include measurements in the sand bed region of Bays l'1, 3D, SD, 7D, 9A,13A,13C,13D,15A, ISD and 17A which are not covared by the cathodic protection system.

It also includes measuremt.nts in the sand bed region between Bays 17 and 19 which is covered by the cathodic protection system, but does not have a reference electrode to monitor its etfectiveness in this region.

l Some measureme,nts la the long term monitoring program are to be taken at each outage of opportunity, while others are taken during each refueling outage. The functit,nal requirements for these l

inspections are documented in Ref. 3.4.

The primary purpose of the UT measurements in the sand bed region is to determine the corrosion rate and monitor it over time. When the cathodic

(

protection system is installed and operating, these data will be used to monitor its effectiveness. The purpose of the measurements at other locations is to confirm that corrosion is not occurring in those regions.

This report documents the assumptions, methods, and results of the statistical analyses used to evaluate the corrosion rate in each of these regions.

The complete analyses are documented in Ref. 3.7.

l

A

{

TDR 948 R:v. O i

Page 4 of 26 1.2 Statistical Inferences 1.2.1 Statistical Hypotheses The cbjective of these statistical analyses is to make statistical decisions or inferences about populations on the basis of sample information.

In attempting to reach these decisions, it is useful to make assumptions or guesses about the populations involved.

Such assumptions, which may or may not be true, are called statistical hypotheses and in general are statements about the probability distributions of the populations.

In many instances we formulate a statistical hypothesis for the sole purpose of rejecting or nullifying it.

For example, in performing a t-test to test the difference between the means of two samples we first hypothesize that there is no difference between the two means. This is referred to as a null hypothesis. Any hypothesis which differs from the null hypothesis is referred to as an alternative hypothesis, eg., the means are not equal, one mean is greater than the other, etc.

1.2.2 Tests of Hypotheses and Significance If on the supposition that a particular null hypothesis is true we find that results observed in a random sample differ markedly from those expected under the hypothesis on the basis of pure chance, we would say that the observed differences are significant and we would be inclined to reject the hypothesis (or at least not accept it on the basis of the evidsnee obtained).

Procedures which enable us to decide whether to reject or not reject hypotheses are called tests of hypotneses.

I 1.2.3 Type I and Type II Errors If we reject a hypothesis when it should not have been rejected, we say that a Type I error has been made.

If, on the other hand, we fail to reject a hypothesis when it should have been rejected, we say a Type II error has been I

made. In either case a wrong decision or error in judgement has occurred.

l 1.7.4 Level of Sionificance In testing a given hypothesis, the maxinum probability with which we would be willing to risk a Type I error is called the level of significanco of the test. This probability is usually denoted by the Greek letter alpha.

In practice a level of significance of 0.05 (5%) or 0.01 (1%) is customary.

If 0.05 has been selected, we say that the hypothesis is rejected (or not rejected) at a level of significance of 0.05.

i l

1 l

o. M TDR 948 R v. 1 Page 5 of 26 I

2.0

. METHODS 2.1 Selection of Areas to be Monitored A program was initiated during the 11R outage to characterize the l

corrosion and to determine its extent.

The details of this i

inspection program are documented in Ref. 3.3.

The greatest corrosion was found via UT measurements in the sand bed region at the lowest accessible locatioss.

Where thinning was detected, additional measurements were tcade in a cross pattern at the thinnest section to determine the extent in the vertical and horizontal directions. Having found the thinnest locations, measurements were made over a 6"-5" grid.

To determine the vertical profile of the thinning, a trench was excaveted into the floor in Bay 17 and Bay S.

Bay 17 was selected since the extent of thinning at the floor level was greatest in that area.

It was determined that the thinning below the top of the curb was no more severe than above the curb, and became less severe at the lower portions of the sand cushion.

Bay 5 was excavated to determine if the thinning line was lower than the floor level in areas where no thinning was detected above the floor. Thors were no significant indications of thinning in Bay 5.

It was on the basis of these findings that the 6"x6" grids in Bays 11A, lic, 17D, 19A, 19B and 19C were selected as representative locations for longer term monitoring.

The initial measurements at these locations were taken in December 1986 without a template or markings to identify the location of each measurement.

Subsequently, the location of the 6"x6" grids were permanently marked on the drywell shell and a template is used in conjunction with these markings.to locate the UT probe for successive measurements. Analyses have shown that including the non-template data in the data base creates a significant variability in the thickness data. Therefore, to minimize the effects of probe location, only those data sets taken with the template are included in the analyses.

The presence of water in the sand bed also raised concern of-potential corrocion at higher elevations. Therefore, UT measurements were taken at the 51' and 87' elevations in 1987 during the 11M outage. The measurements were taken in a band on 6-inch centers at all accessible regions at these elevations.

Where these measurements indicated potential corrosion, the measurements spacing was reduced to 1-inch on centers.

If these additional readings indicated potential corrosion, measurements were taken on a 6"x6" grid using the template.

It was on the basis of these inspections that the 6"x6" grids in Bay 5 at elevation 51' and in bays 9, 13 and 15 at the 87' elevation were selected as representative locations for long term monitoring.

/t 9

TDR 048 Rov. O Page 6 of 26 The long term monitoring program was expanded as follows during the 12R outaget (1) Measurements on 6"x6" grids in the sand bed region of Bays 9D, 13A, ISD and 17A. The basis for selecting these locations is that they were originally considered for cathodic protection but are not included in the system being installed.

(2) Measurements on 1-inch centers along a 6-inch horizontal strip in the sand bed region of Bays 10, 3D, 50, 7D, 9A, 13C, and i

15A. These locations were selected on the basis that they are representative of regions which have experienced nominal corrosion and are not within the scope of the cathodic protection system.

(3) A 6"x6" grid in the curb cutout between Bays 17 and 19.

The purpose of ?hese measurements is to monitor corrosion in this region which is covered by the cathodic protection system but does not have a reference electrode to monitor its performance.

2.2 UT Heasurements The UT rneasurements within the scope of the long term monitoring program are performed in accordance with Ref. 3.4.

This involves taking UT measurements using a template with 49 holes laid out on a 6"x6" grid with 1" between centers on both axes.

The center row is used in those bays where only 7 measurements are made along a 6-inch horizontal strip.

The first set of measurements were made in December 1986 without the use of a template. Ref. 3.4 specifies that for all subsequent readings,"QA shall verify that locations of UT measurements performed are within 11/4" of the location of the 19B6 UT measurements.

It also specifies that all subsequent measurements are to be within 11/8" of the designated locations.

2.3 Data at Plug Locations Seven core samples, each appro,:tmately two inches in diameter were removed from the drywell vessel the11.' These samples were evaluated in Ref. 3.2.

Five of tiese samples were removed within the 6"x5" grids for Bays 11A,170,19A,19C and Bay 5 at elevation 51'.

These locations were repaired by weldirig a plug in each hole.

Since these plugs are not representative of the drywell shell, UT measurements at these locations on the 6"x6" grid must be dropped from each data set

TDR 948 R;v. 0 i

Fage 7 of 26 The following specific grid points have been deleted:

Bay Area Points 11A 23, 24, 30, 31 17D 15, 10, 22, 23

)

19A 24, 25, 31, 32 19C 20, 26, 27, 33, 5

20, 26, 27, 28, 33, 34, 35 2.4 Bases for Statistical Analysis of 6"x6" Grid Data 2.4.1 Assumptions The statistical evaluation of the UT measurement data to determine the corrosion rate at each location is based on the following assumptions:

(1)

Characterization of the scattering of data over each 6"x6" grid is such that the thickness measurements are normally distributed.

(2) once the distribution of data for each 6"x6" grid is found to be normal, then the mean value of the thickness is the appropriate representation of the average condition.

(3)

A decrease in the mean value of the thickness with time is representative of the corrosion occurring within the 6"x6" grid.

(4)

If corrosion has ceased, the mean value of the thickness will not vary with time except for random errors in the UT measurements.

(5)

If corrosion is continuing at a constant rate, the mean thickness will decrease linearly with time.

In this case, linear regression analysis can to used to fit the mean thickness values for a given-zone to a straight line as a function of time. The corrosion rate is equal to the slope of the line.

The validity of these assumptions is assured by:

(a)

Using more than 30 data points per 6"x6" grid (b)

Testing the data for normality at each 6"x6" grid location.

(c)

Testing the regression equation as an appropriate model to describe the corrosion rate.

t o

TDR 948 R:v. O pcg3 8 of 26 These tests are discussed in the following section.

In cases where one or more of these assumptions proves to be invalid, non-parametric analytical techniques can be used to evaluate the data.

2.4.2 Statistical Approach The following steps are performed to test and evaluate the UT measurement data for those locations where 6"x6" grid data has been taken at least three times:

(1)

Edit each 49 point data set by setting all invalid points to zero.

Invalid points are those which are declared invalid by the UT operator or are at a plug location.

(The computer programs used in the following steps ignore all zero thickness data points.)

(2)

Perform a chi-squared goodness of fit test of each 49 point data set to ensure that the assumption of normality is valid at the 954 and 994 confidence levels.

(3)

Calculate the mean thickness of each 49 point data set.

(4)

Using the mean thickness values for each 6"x6" grid, perform linear regression analysis over time at each location.

(a) perform F-test for significance of regression at the 95% :onfidence level. The result of this test indicates whether or not the e

regression model is more appropriate than the mean model In other words, it tests to see if the variation of the regression model is statistically significant over that of a mean model.

(b)

Calculate the co-efficient of determination (R*) to assess how well the regression model explains the percentage of total error and thus how useful the regression line will be as a predictor.

(c)

Determine if the residual values for the regression equations are normally distributed.

(d)

If the regression model is found to be appropriate, calculate the y-intercept, the slope and their respective standard errors.

The y-intercept represents the fitted mean thickness at time zero, the slope represents

TCR 948 R0v. O Page 9 of 26 the corrosion rate, and the standard errors represent the uncertainty or random error of these two parameters.

(5)

Use a z score of 2.58 and the standard deviatien to establish a 99% confidence interval about the c.ean thickness values for each 6"x6" grid location to determine whether low thickness measuraments or

" outliers" are statistically significant.

If the data points are greater than the 99% lower confidence limit, then the difference between the value and the mean is deemed to be due to expected random error.

However, if the data point is less than the lower 99%

confidence limit, this implies that the difference is statistically significant and is probably not due to chance.

2.5 Analysis of Two 6"x6' Grid Data Sets Regression analysis is inappropriate when data is available at only two points in time. However, the t-Test can be used to determine if the means of the two data sets are statistically different.

2.5.1 Assuretions This analysis is based upon the following assumptions (1)

The data in each data set is normally distributed.

(2)

The variances of the two data sets are equal.

2.5.2 Statistical Approach v

The evaluation takes place in three stepst (1)

Perform a chi-squared test of each data set to ensure that the assumption of normality is valid at the 95%

and 99% confidence levels.

(2)

Perform an F-test of the two data sets being compared to ensure that the assumption of equal variances is valid at the 954 and 99% confidence levels.

(3)

Forform a two-tailed t-Test for two independent samples to determine if the means of the two data sets are statistically different at the 0.05 and 0.01 levels of significance.

A conclusion that the means are not statistically different is interpreted to mean that significant corrosion did not occur over the time period represented by the data.

However, if equality of the means is redocted, this implies that the difference is statistically significant and could be due to corrosion.

U TD3 948 R;v. 0 Pag 3 10 of 26 2.6 Analysis of Sincie 6"x6" Grid Data set In those cases where a 6"x6" data so; is taken at a given location for the first time during the current outage, the only other data to which they can be compared are the UT survey measurements taken in 1986 to identify the thinnest regions of the drywell shell in the sand bed region. For the most part, these are single point measuraments which were taken in the vicinity of the 49-point data set, but not at the exact location.

Therefore, rigorous statistical analysis of these single data sets is impossible.

However, by making certain assumptions, they can be compared with the previous data points.

If more extensive data is available at the location of the 49-point data set, the t-test can be used to compare the means of the two data sets as described in paragraph 2.5.

When additional measurements are made at these exact locations during future outages, more rigorous statistical analyses can be employed.

2.6.1 Assumptions The comparison of a single 49-point data sets with previous data from the same vicinity is based on the following assumptionst (1)

Characterization of the scattering of data over the 6"x6" grid is such that the thickness measurements are normally distributed.

(2)

Once the distribution of data for the 6"x6" grid is found to be normal, then the mean value of the thickness is the appropriate representation of the e

average condition.

(3)

The prior data is representative of the condition at this location in 1986.

2.6.2 Statistical Approach The evaluation takes place in four steps:

(1)

Perform a chi-squared test of each data set to ensure that the assumption of normality is valid at the 95%

and 99% confidence levels.

(2)

Calculate the mean and the standard error of the mean of the 49-point data set.

(3)

Determine the two-tailed t value from a t distribution table at levels of significance of 0.05 and 0.01 for n-1 degrees of freedom.

o e

TDR 948 R3v. O page 11 of 26 t

(4)

Use the t value and the standard error of the mean to calculate the 95% and 99% confidence intervals about the mean of the 49-point data set.

(5)

Compare the prior data point (s) with these ccnfidence intervals about the mean of the 49-point data sets.

If the prior data falls within the 95t confidence intervals, it provides some assurance that significant corrocion has not occurred in this region in the period of time covered by the data.

If it falls within the 99%

confidence limits but not within the 95% confidence limits, this implication is not as strong.

In either case, the corrosion rate will be interpreted to be "Not Significant".

If the prior data falls above the upper 99% confidence limit, it could mean either of two things (1) significant corrosion has occurred over the time period covered by the data, or (2) the prior data point was not representative of the condition of the location of the 49-point data set in i

1986. There is no way to differentiate between the two.

In this case, the corrosion rate will be interpreted to be "possible".

If the prior data falls below the lower 99% confidence limit, it means that it is not representative of the condition at this location in 1986.

In this case, the corrosion rate will be interpreted to be " Indeterminable".

2.7 Analysis of Single 7-Point Data Set In those cases where a 7-point data set is taken at a given location for the first time during the current outage, the only other data to which they ran be compared are the UT survey measurements taken in 1966 to identify the thinnest regions of the drywell shell in the sand bed region. Fcr the most part, these are single point measurements which were taken in the vicinity of the 7 point data sets, but not at the exact locations. However, by making certain assumptions, they can be compared with the previous data points.

If more extensive data is available at the location of the 7-point data set, the t-test can be used to compare the means of the two data sets as described in paragraph 2.5.

When additional measurements are made at these exact locations during future outages, more rigorous statistical analyses can be employed.

2.7.1 Assumptions The comparison of a single 7-point data sets with previous data from the same vicinity is based on the following assumptions:

(1)

The corrosion in the region of each 7-point data set is normally distributed.

TDR 948 Rov. 0 Page 12 of 26 (2)

The prior data is representative of the condition at this location in 1986.

The validity of these assumptions cannot be verified.

2.7.2.

Statistical Approach The evaluation takes place in four steps:

(1)

Calculate the mean and the standard error of the mean of the 7-point data set.

(2)

Determine the two-tailed t value using the t distribution tables at levels of sige.ificance of 0.05 and 0.01 for n-1 degrees of freedom.

(3)

Use the t value and the standard error of the mean to calculate the 95% and 99% confidence intervals about the mean of the 7-point data set.

(4)

Compare the prior data point (s) with these confidence intervals about the mean of the 7-point data sets.

If the prior data falls within the 95% confidence intervals, it provides some assurance that significant corrosion has not occurred in this region in the period of time covered by the data.

If it falls within the 994 confidence limits but not within the 95% confidence limits, this implication is not as strong.

In either case, the corrosion rate will be interpreted to be "Not Significant".

If the prior data falls above the upper 99% confidence interval, it could mean either of two things (1) significant corrosion has occurred over the time period covered by the data, or (2) the prior data point was not representative of the condition of the location of the 7-point data set in 1986.

There is no way to differentiate between the two.

In this case, the corrosion rate will be interpreted to be "possible".

If the prior data falls below the lower 994 confidence limit, it means that it is not representative of the condition at this location in 1986.

In this case, the l

corrosion rate will be interpreted to be " Indeterminable".

1 l

2.8 Evaluation of Drywell Mean Thickness l

l This section defines the methods used to evaluate the drywell i

thickness at each location within the scope of the long term l

monitoring program.

l l

2.8.1 Evaluation of Mean Thickness Using Regression Analysis l

l The following procedure is used to evaluate the drywell L

mean thickness at those locations where regression analysis has been deemed to be more appropriate than the mean model.

i l

l

TDR 948 R:v. O P ge 13 of 26 (1)

The best estimate of the mean thickness at these locations is the point on the regression line corresponding to the time when the most recent set of measurements was taken.

In the SAS Regression Analysis output (Ref. 3.7), this is the last value in the column labeled " PREDICT VALUE"-

(2)

The best estimate of the standard error of the mean thickness is the standard error of the predicted value used above.

In the SAS Regression Analysis output, this is the last value in the column labeled "5fD ERR PREDICT".

(3)

The two-sided 95% confidence interval about the mean thickness is equal to the mean thickness plus or minus t times the estimated standard error of the mean. This is the interval for which we have 95%

confidence that the true mean thickness will fall within.

The value of t is obtained from a t distribution table for equal tails at n-2 degrees of freedom and 0.05 level of significance, where n is the number of sets of measurements used in the regression analysis. The degrees of freedom is equal to n-2 because two parameters (the y-intercept and the slope) are calculated in the regression analysis with n mean thicknesses as input.

(4)

The one-sided 95% lower limit of the mean thickness is equal to the estimated mean thickness minus t times the estimated standard error of the mean.

This is the mean thickness for which we have 95%

confidence that the true mean thickness does not fall below.

In this case, the value of t is obtained from v

a t distributian table for one tail at n-2 degrees of freedom and 0.05 level of significance.

2.8.2 Evaluation of Mean Thickness Using Mean Model The following procedure is useid to evaluate the drywell mean thickness at those locations where the mean model is deemed to be more appropriate than the linear regression model. This method is consistent with that used to evaluate the mean thickness using the regression nodel.

(1)

Calculate the mean of each set of UT thickness measurements.

(2)

Sum the means of the sets and divide by the number of sets to calculate the grand mean.

This is the best estimats of the mean thickness.

In the SAS Regression Analysis output (Ref. 3.7), this is the value labelled "DEP MEAN".

- = _ - _=

e TDR 948

/

R3v. O Page 14 of 26 (3)

Using the means of the sets from (1) as input, calculate the standard error. ThAs is the best estimate of the standard error of ?.he mean thickness.

(4)

The two-sided 95% confidence interval about the mean thickness is equal to the mean thickness plus or minus t times the estimated standard error of the mean.

This is the interval for which we have ?5%

confidence that the true mean thickness will f all within. The value of t is obtained from a t distribution ' vle for equal tails at n-1 degrees of freedom and 0.05 level of significance.

(5)

The one-sided 95% lower limit of the mean thickness is equal to the estimated mean thickness minus t times the estimated standard error of the mean.

This is the mean thickness for which we have 95%

confidence that the true mean thickness does not fall below.

In this case, the value of t is obtained from a t distribution table for one tail at n-1 degrees of freedom and 0.05 level of significance.

2.8.3 Evaluation of Mean Thickness Using Single Data Set The following procedure is used to evaluate the drywell thickness at those locations where only one set of measurements is available.

(1) calculate the mean of the set of UT thickness measurements.

This is the best estimate of the mean thickness.

(t) calculate the standard error of the mean for the set of UT measurements. This is the best estimate of the l

standard error of the mean thickness, l

1 Confidence intervals about the mean thickness cannot be calculated with only one data set available.

l

3.0 REFERENCES

l 3.1 GPUN Safety Evaluation SE-000243-002, Rev. O, "Drywell Steel Shell Plate Thickness Reduction at the Base Sand Cushion Entrenchment Region" 3.2 GPUN TDR 854, Rev. O, "Drywell Corrosion Assessment" l

3.3 GPUN TDR 851, Rev. O, " Assessment of Oyster Creek Drywell Shell" 3.4 GPUN Installation Specification IS-328227-004, Rev. 3, "Punctional Requirements for Drywell Containment Vessel Thickness Examination" 1-

--e v

w w

i e

TDR 948 Rev. O a

Pego 15 of 26 3.5 Applied Regression Analysis, 2nd Edition, N.R. Draper & H. Smith, John Wiley & Sons, 1981 j

3.6 Statistical concepts and Methvas G.K. Bhattacharyya & R.A. Johnson, John Wiley & sons, 1977 3.7 GPUN Calculation C-1302-187-5300-005, Statistical Analysis of i

Drywell Thickness Data Thru 12/31/88.

4.0 EVALUATION OF DATA THROUGH 12/31/88 4.1 Results for 6"x6" Grids in Sand Bed Region at Original Locations 4.1.1 Bay 11A 5/1/87 to 10/8/88 Six 49-point data sets were available for this bay covering the time period from May 1, 1987 to October 8, 1988.

Since a plug lies within this region, four of the points were voided in each data set.

The data were analyzed as described in paragraphs 2.4 and 2.8.2.

(1) The data are normally distributed.

(2)

The mean model is more appropriate than the regression codel.

(3)

The current mean thickness + standard error is 908.6

+5.0 mils.

(4)

Tnere was no significant corrosion from May 1, 1987 to October 8, 1988.

4.1.2 Bey lic 5/1/87 to 10/8/88 Five 49-point data sets were available for this bay ccvering the time period from May 1, 1987 to October 8, 1988.

These data were analyzed as described in paragraphs 2.4 and 2.8.2.

The initial analysis of this data indicated that the data are not normally distributed.

The lack of normality was tentatively attributed to minimal corrosion in the upper half of the 6"x6" grid with more extensive corrosion in the lower half of the grid. To test this hypothesis, each data set was divided into two subsets, with one containing the top three rows and the other containing the bottom four rows.

The top subset was normally distributed but the bottom subset was not. For both subsets, the mean model is mora appropriate than the regression model.

Since there is an observable decrease in the mean thickness with time, there appears to be some on-going corrosion at I

i this location. Further analysis is required.

l l

t

R s

e TDR 94B

.- V Rov. O Page 16 of 26 The current mean thickness 1 standard error is 916.6 110.4 mils for the lower suhdet and 1057.6 116.9 mils for the upper subset.'

4.1.3 Bey 17D:

2/17/87 to 10/8/88 Six 49-point data sets were available for this bay covering the time period f rom February 17, 1987 te October 8, 1988.

Since a plug lies within this region, four of the points were voided in each data set.

The data were analyzed as described in paragraphs 2.4 and 2.8.1.

(1)

The data are normally distributed.

(2)

The regression model is appropriate.

(3)

The regression model explains 84% of the total 4

variation about the mean.

(4)

The residuals are normally distributed.

(5)

The current mean thickness 1 standard error is 864.8 16.8 mils.

(6)

'The corrosion rate i standard error is -27.6 16.1 mils per year.

(7)

The measurements below 800 mils were tested and determined not to be statistically different from the mean thickness.

4.1.4 Bay 19At 2/17/87 to 10/8/88 v

Six 49-point data sets were available for this bay covering the time period from February 17, 1987 to October 8, 1988.

Since a plug lies within this region, four of the points were voided in each data set. The data were analyzed as described in paragraphs 2.4 and 2.8.1.

(1)

The data are nearly normally distributed.

(2)

The regression model is appropriate (3)

The regression model explains 88% of the total variation about the mean.

i (4)-

The residuals are normally distributed.

(5)

The current mean thickness 1 standard error is 837.9 14.8 mils.

(6)

The corrosion rate 1 standard error is -23.7 14.3 mpy.

m i

TDR 948 s

Rev. O page 17'of 26 (7)

One data point that was below 800 mils at two different times was tested and determined to be statistically different from the mean thickness. The probability of this occurring is less than 1% at each specific time.

4.1.5 Bay 19B 5/1/87 to 10/8/8B Five 49-po2nt data sets were available for this bay covering the time period from May 1, 1987 to October 8, 1988. The data were analyzed as described in paragraphs 2.4 and 2.8.1.

(1)

The data are normally distributed.

(2)

The regression model is appropriate.

(3)

The regression model explains 99% of the total variation about the mean.

(4)

The residuals are normally distributed.

(5)

The current mean thickness i standard error is 856.5 10.5 mils.

(6)

The corrosion rate standard error is -29.2 10.5 mpy.

(7)

The maarurements below 800 mils were tested and determined not to be statistically different from the mean thickness.

4.1'. 6 Bhy 19c:

5/1/87 to 10/8/88 Five 49-point data sots were available for.this bay covering the time period from May 1, 1987 to October 8, 1988.

Since a plug' lies within this region, four of the points were voided in each data set.

The data were analyzed as described in paragraphs 2.4 and 2.8.1.

(1)

The data are normally diatributed.

(2)

The regression model is appropriate.

(3)

The regression model explains 91% of the total variation about the mean.

(4)

The residuals are normally distributed.

(5)

The current mean thickness i standard error is 860.9 14.0 mils.

(6)

The corrosion rate 1 standard error is -25.9 14.1 mpy.

e l

TDR 948

.s R;v. O Page 18 of 26 i

i (7)

The measurements below 800 mils were tested and determined not to be statistically different from the mean thickness.

4.2 Results for 6"x6" Grids in Sand Bed Region at New Locations 4.2.1 Bay 9D: 11/25/86 to 12/19/88 The 6"x6" grid data was taken in December 1988 during the 12R outage.

This bay was considered for cathodic protection, but is not within the scope of the cathodic protection system being installed. The primary purpose of this data is to establish a base line to monitor corrosion in the future. However, previous measurements were.taken in November 1986 in a 10-point 6"x6" cruciform pattern.

Measurements were also taken in a 6"x6" grid in December 1986. The new data were compared with both of the previous data sets.

These comparisons were made using the chi-squared test, F-test and two-tailed t-test as described in paragraph 2.5.

The mean thickness was determined as i

described in paragraph 2.8.3.

(1)

The data are normally distributed.

(2)

The variances are equal in both comparisons.

(3)

It is appropriate to use the two-tailed t-test in both comparisons.

(4)

The difference between the means of the 1988 49-point data set and the 1986 10-point data set is not significant.

However, there is a significant difference between the means of the 1988 49-point v

data set and the 1986 49-point data set.

Therefore, significance of the corrosion rate is classified as

" Indeterminable'.

(5)

The current mean thickness 1 standard error is 1021.4 19.7 mils.

4.2.2 Bay 13A 11/25/86 to 12/17/88 The 6"x6" grid data was taken-for the first time in l

December 1988 during the 12R outage. This bay was i

considered for cathodic protection, but is not within the

~

scope of the cathodic protection being installed.

The primary purpose of this-data is to establish a base line to monitor corrosion in the future. However, previous measurements were taken in November 1986 in abutting 6"x6" cruciform patterns across the entire bay. As a best approximation, 13 of these data points are at the same location as the new 6"x6" grid data set. Therefore, the new data were first compared with these 13 data points, and then with 21 data points which include the 13 plus 8

TDR 948 Rev. 1 s

page 19 of 26 additional points withir. one inch on either side.

These comparisons were made using the chi-squared test, F-test and two-tailed t-test as described in paragraph 2.5.

The i

mean thickness was determined as described in paragraph 2.8.3.

(1)

The data are normally distributed.

(2)

The variances are equal in both comparisons, j

(3)

It is appropriate to use the two-tailed t-test in both comparisons.

(4)

The difference between the means of the data sets is not signficant.

Therefore, the corrosion is classified as "Not Significant".

(5)

The current mean thickness 2 standard error is 905.3 110.1 mils.

4.2.3 Bay ISD: 11/25/86 to 12/17/88 The 6"x6" grid data was taken for the first time in December 1988 during the 123 outage.

This bay was considered for cathodic protection, but is not within the scope of the cathodic protection being installed.

The primary purpose of this data is to establish a base line to monitor corrosion in the future. However, a previous 1-point measurement was taken in November 1986. The location of this point may have been somewhat removed from the location of the new 6"x6" grid data set. The previous measurement was comoared with the new data set using the methods described in paragraph 2.6.

The mean thickness was determined as described in paragraph 2.8.3.

(1)

The new data are normally distributed.

(2)

The previous measurement falls above the 99% upper bound of the new data.

(3)

This implies that the corrosion may have occurred in the time period covered by this data. Therefore, the corrosion is classified as "Possible".

(4)

The current mean thickness i standard error is 1056.0 19.1 mils.

4.2.4 Bay 17A: 11/25/86 to 12/17/f8 The 6"x6" grid data was taken for the first time in December 1988 during the 12R outage.

This bay was considered for cathodic protection, but is not within the scope of the cathodic protection being installed. The primary purpose of this data is to establish a base line to monitor corrosion in the future. However, a previous

o TDR 948 L

Rov. 0

,o a

pago 20 of 26 1-point measurement was taken in Novenber 1986. The location of this point may have been somewhat removed from the location of the new 6"x6" grid data set. The previous measurement was compared with the new data set using the methods described in paragraph 2.6.

The mean thickness was determined as described in paragraph 2.8.3.

(1)

The new data are not normally distributed. However, the top three rows and the bottom four rows are each l

normally distributed.

(2)

The previous measurement falls below the 99%

confidence interval for the top three rows, and above the 99% confidence interval for the bottom four rows.

(3)

The corrosion is classified as " Indeterminable".

(4)

The current mean thickness + standard error is 1133.1 1 9 milsfor the top three rows and 957.4 19.2 mils 6

1 for the bottom four rows.

4.3 Results for 6"x6" Grids at Upper Elevations 4.3.1=

Bay 5 51' Elevation: 11/01/87 to 10/8/88 Three 49-point data sets were available for this bay covering the time period from November 1, 1987 to October 8, 1988. The data were analyzed as described in paragraphs 2.4 and 2.8.1.

(1)

Except for the first data set, the data are normally distributed.

(2)

The regression model is appropriate.

.(3)

The regression model explains 99% of the total variation about the mean.

(4)

The residuals are normally distributed.

(5)

The current mean thickness 1 standard error is 750.0 10.02 mils.

(6)

The corrosion rate 1 standard error is -4.3 10.03 mpy.

(7)

One data point was determined to be statistically different from the mean thickness.

The probability of this occurring due to expected random error is less than 1% at each specific time.

i l

l

TDR 948

.s Rev. O Page 21 of 26 4.3.2 Bay 9 87' Elevation: 11/6/87 to 10/8/88 Three 49-point data sets were available for this bay covering the time period f rom November 6,1987 to October 8, 1988.

The data were analyzed as described in paragraphs 2.4 and 2.8.2.

(1)'

The data are normally distributed.

(2)

The mean model is appropriate than the regression model.

(3)

There was no significant corrosion from November 6, 1987 to October 9, 1988.

(4)

The current mean thickness 1 standard error is 620.3 11.0 mils.

4.3.3 Bay 13 87' Elevation: 11/10/87 to 10/8/88 Three 49-point data sets were available for this bay covering the time period from November 10, 1987 to October 8, 1988.

The data were analyzed as described in paragraphs 2.4 and 2.8.2.

(1)

The data are normally dir e -abuted.

(2)

The aan model is more appropriate than the regression model.

(3)

There was no significant corrosion from November 10, 1987 to October 8, 1988.

%8 (4)

The current mean thickness 1 standard error is 635.6 10.7 mils.

4.3.4-Bay 15 87' Elevation: 11/10/87'to 10/6/88 Three 49-point data sets were available for this bay covering the time period from November 10, 1987 to October 8, 1988.

The data were analyzed as described in paragraphs 2.4 and 2.8.2.

(1)

The data are normally distributed.

(2)

The mean model is more appropriate than the regression model'.

(3)

There was no significant corrosion from November 10, 1987 to October 8, 1988.

(4)

The current mean thickness 1 standard error is 634.8 10.7 mils.

IDR 948 Rev 0 Page 22 of 26 4.4 Results for Multiple 6"x6" Grids in Trench 4.4.1 Bay 17D Trencht 12/9/86 to 12/23/88 The two sets of measurements in the Bay 17D Trench were taken on December 9, 1986 and December 23, 1988. The 1986 s

data is a 7 column by 36 row array. The 1988 data is a 7 column by 42 row array. The 1986 data is at the same elevation as the lower 36 rows of the 1988 data, but is centered about 3-/12 inches to the left of the 1988 data.

To compare these two data sets, the 1986 data set and the lower 36 rows of the 1988 data set were each subdivided into six 7 column by 6 row subsets. Each pair of subsets ut was compared as described in paragraphs 2.5 and 2.8.3.

Fourth Subset From The Top:

The chi-squared statistic for the fourth subset from the top from the 1986 data set slightly exceeded the critical value for level of significance of 0.05, but was within the g~

critical value for level of significance of 0.01.

Also, the F statistic exceeded the critical value for levels of significance of 0.05 and 0.01.

Therefore, it is inappropriate to apply the two-tailed t-test babed on equal variances. However, the approximate t-test based on unequal variances can be applied. From the results of this-test, it is concluded that the difference between the mean thicknesses is not significant. This implies that corrosion at this location was not significant.

All Other Subsets:

(4)

The~ data are normally distributed.

-(2)

The variances are equal.

(3)

Comparison of the means using the two-tailed t-test is appropriate.

(4)

The difference between the means of the subsets-was not significant. This implies that there was no significant corrosion in the period from December 9, 1986 to December 23, 1988..

(5)

The current mean thickness i standard error of the top subset is 981.2 16.7 mila.

This is the thinnest area in the trench.

W

TDR 948 Rov. 0 Page 23 of 26 4.4.2 Bays 17/19 Frame Cutout: Decerber 1998 Two sets of 6"x6" grid measurements were taken in December 1988.

The upper one is located 25" below the top of the high curb and the other below the floor.

There is no previous data.

The upper location has been added to the long term monitoring program. With no prior data, the only possible analysis was to check the data sets for normality using the chi-squared test.

The data at ths upper location are not normally distributed.

The lack of normality was tentatively attributed to minimal corrosion in the lower half of the 6"x6" grid with more extensive corrosion in the upper half of the grid. To test this hypothesis, each data set was divided into two subsets, with one containing the top three rows and the other containing the bottom four rows. These subsets proved to be normally distributed, thus confirming the hypothesis. The current mean thickness 1 standard error is 981.7 14.4 mils for the top three rown and 1003.8 16.6' mils for the bottom four rows.

The data at the location below the floor is normally distributed. Also, the mean thickness is higher than at the upperflocation. The mean thickness i standard error is 1034.1 16.8 mils.

4.5 Results for 6" Stripa in Sand Bed Region 4.5.1 Bay 10: 11/25/86 to 12/17/88 The 7-point data set was taken in December 1988 and a single point measurement was taken in November 1986. The date were compared as described in paragraph 2.7. 'The previu s measurement falls below the 99% lower bound of the n

new 7-point data set. Thus, the corrosion rate is class-'

ified as indeterminable. The current mean thickness 1 standard error is 1114.7 130. 6. mils.

4.5.2 Bay 3D: 11/25/86 to 12/17/88 The 7-point data set was taken in December 1988 and a single point measurement was taken in November 1986. The data were compared as described in paragraph 2.7.

The previous measurement falls within the 99% upper and lower bounds of.the new 7-point data set. This implies that significant corrosion has not occurred at this location in-the time period covered by the data. The current mean thickness i standard error is 1177.7 15.6 mils..

4.5.3 Bay 50: 11/25/86 to 12/17/88 The 7-point data set was taken in December 1988 and a single point measurement was taken in November 1986. The data were compared as~ described in paragraph 2.7.

The

TDR 948 R v. O Page 24 of 26 previous measurement falls within the 95% upper and lower bounds of the new 7-point data set. This implies that significant corrosion has not occurred at this location in the time period covered by the data.

The current mean thickness rate i standard error is 1174.0 12.2 mils.

4.5.4 Bay 7D: 11/25/86 to 12/17/88 The 7-point data set was taken in Decembwr 1988 and a single point measurement was taken in November 1986. The data was compared as described in paragraph 2.7.

The previous measurement falls just above the 99% upper bound of the new 7-point data set. This implies that corrosion has possibly occurred at this location in the time period covered by the data. The current mean thickness i standard error is 1135.1 +4.9 mils.

l 4.5.5 Bay 9A: 11/25/86 to 12/17/88 The 7-point data set was taken in December 1988 and a L

single point measurement was taken in November 1986.

The data were compared as described in paragraph 2.7.

The previous measurement falls below the 99% lower bound of the l

new 7-point data set.

Thus, the corrosion rate is class-ified as indeterminable.

The current mean thickness 1 standard error.is 1154.6 14.8 mils.

4.5.6 Bay 13C: 11/25/86 to 12/17/88 l

The 7-point data set was taken in December 1988 and a single point measurement wasitaken in November 1986. The L

data were compared as described in paragraph 2.7.

The previous measurement falls within the 95% upper and lower bounds of the new 7-point data set.

This implies that significant corrosion has not occurred at this. location in l

the-time period covered by the data.

The current mean l

thickness 1 standard error is 1147.4 13.7 mils.

4.5.7 Bay 13D: 11/25/86 to 12/17/88 The 7-point data set was taken in December 1988 and a single point measurnment was taken in November 1986. The data were compared as described in paragraph 2.7.

The-previous measurement falls within the 95% upper and lower L

bounds of the new 7-point data set.

This implies that l

significant corrosion has not occurred at this location in the time period covered by the data. The current mean thickness 1 standard error is 962.1 122.3 mila.

4.5.8 Bay 15A: 11/25/86 to 12/19/88 i

The 7-point data set was taken in December 1988 and a single point measurement was taken in November 1986. Also, a 6"x6" grid data set was taken on December 2, 1986 at this l'

.x.

  • O TDR 948 Rev. 1 page 25 of 26 location. As a best approximation, the first 5 points in the 7-point data set.are at the same location as points 38 to 42 of the 6"x6" grid. These five points all fall within the 99% confidence interval of the new 7-point data set.

The single measurement falls below the 99% lower bound.

This implies that significant corrosion has not occurred at this location in the time period covered by the data. The current mean thickness i standard error is 1120.0 +12.6 mils.

4.6 Summary of Conclusions Bay & Area Location Corrosion Rate **

Mean Thickness ***

4.6.1 6"x6" Grids in Sand Bed Region at Original Locations 11A Sand Bed Not significant 908.6 15.0 mils 11C Sand Bed Indeterminable 916.6 +10.4 mils 17D Sand Bed

-27.6 16.1 mpy 864.8

+6.8 mils 19A Sand Bed

-23.7 14,3 mpy 837.9 14.8 mils 19B Sand Bed

-29.2 +0.5 mpy 856.5 10.5 mils 19C

, Sand Bed

-25.9 +4.1 mpy 860.9 14.0 mils 4.6.2 ~ 6"x6" Grids in Sand Bed Region at New Locations 90 Sand Bed Indeterminable

  • 1021.4 19.7 mils

.13A Sand Bed Hot significant*

905.3 110.1 mils ISD Sand Bed Possible*

1056.0 19.1 mils 17A Sand Bed Indeterminable

  • 957.4

+9.2 mils 4.6.3 6"x6" Grids at Upper Elevations 5

51' Elev.

-4.3_10.03 mpy 750.0 10.02 mils 9

87' Elev.

Not significant 620.3 11.0 mils 13 87' Elev..

Not significant 635.6

+0.7 mils 15 87' Elev.

Not significant 634.8 10.7 mils 4.6.4 Multiple 6"x6" Gride in Trench 17D Trench Not significant*

981.2 16.7 mils 17/19 Frame Cutout Indeterminable

  • 981.7

+4.4 mils

a.

  • c-TDR 948 R0v. 1 P:go 26 of 26 4.6.5 6" Strips in Sand Bed Region ID Sand Bed Indeterminable
  • 1114.7 130.6 mils 3D Sand Bed Hot significant*

1177.7 15.6 mils SD Sand Bed Not significant*

1174.0 12.2 mils

-7D Sand Bed Possible*

1135.1 14.9 mils 9A Sand Bed Indeterminable

  • 1154.6

+4.8 mils 13C Sand Bed Hot significant*

1147.4 13.7 mils 130 Sand Bed Hot significant*

962.1 122.3 mils 15A Sand Bed Hot significant*

1120.0 112.6 mils 4.6.6 Evaluation of Individual Measurements Below 800 Mils One data point in Bay 19A and one data point in Bay 5 Elev. 51' fell outside the 99% confidence-interval and thus are statistically different from the mean thickness.

  • Based on limited data. See text for interpretation.
    • Mean corrosion rate in mils per year i standard error of the mean
      • Current mean thickness in mils 1 standard error of the mean v