OPE!tATING DATA RI:l' ORT DOCKET NO.

50-286 DATE Mnvambe.30, 1978 COh!!'LETI:D I Y

_.h.E.

~nli-TELEPllONE "14 -7 3 9-U L 'd OPElt ATING ST \\ Tt'S Notes

1. Unit Name: Indian i'oint

'a.

3 Muelcar nnwar Plant

2. Iteporting l'eri"d Novenber 1978
3. Licer".ed Thenn:1 Power (.\\lW ):

3925 1013

1. Name; slate Ratie;(Cross.\\lwel:
5. Design Electrical P.ating (Net 51We):

965

6. "asimum Dependable Capacity (Gron alWe):

!^^^

7. blaximum Dependable Capacity (Net alWe):

_2.65

8. If Changes Occur in Capacity Ratings (Items Number 3 Throu;h 7) Since Last Report. Give Reasons:

nena None

9. Power Level To Which Restricted,if Any (Net hlhe):

N/A

10. Reasons For Restri:tions.lf Any:

This Month Yr to.Date Cumulative' 20 8016.

M3

11. Ilours I. Reporting Period
12. Number Of flours Reactor Was Critical 720 6102.32 15083.94
13. Reactor Resenc Shutdown lluurs 0

0 0

14. Ilours Generator On Line 720 san 4.02 14644.75
15. Unit Resene Shutdown liours rs 0

0

16. Gross Thermal Energy Generated (4th!!)

2.1'a.904 15,372,822 39,647,382

17. Gross Electrical Energy Generated (alWil) 710,830 5,142,651 12,846,291 686,676 4,941,408 12,332,787
18. Net Electrical Ener;> Generated (alWill 100 72.4 74.1
19. Unit Senice factor 100 72.4 74.1
20. Unit Asailahdity raetor 99~

A' - o 64.7

21. Unit Capacity raelor (U>ing SIDC Neti 99 63.9 64.7
22. Unit Capacity Factor (Usin;; DEtt Net) 0 3.7 4.0
23. Unit Forced Out.i e !! ate
24. Shuidowns Seheduled Oser Next 6 51onths (Type.Date.and Duration of Eacht:

None

25. If Shut Dow n At l'nd Of Iteport Period. Estimated Darc of Startup:
26. Units in Test Siains (l'rior to Conuncreial Operation):

Foiecast Achiesed INITIA L CRillCALITY INITI AL I Ll'ClItICIIY CONINILitCI \\ L Ol'! It AllON N/A N_

7812156M (

($1/771

Summary of Operating Experience November 1978 Indian Point Unit 3 was synchronized to the bus for a total of 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> producing a gross generation of 710,830 mwe for this reporting pericd.

During the reporting period, the unit experienced one major load reduction.

At 0300, on November 10, 1978, a load reduction to 700 mwe occurred due to the removal of #32 Main Boiler Feed Pump from service. The pump was removed to repair an oil leak. At 1635, on the same day, the plant was returned to full power.

There were no unit trips for the second consecutive reporting period since the refueling outage.

0 9

1

i t

AVERACE DAILY UNIT POWER LEVEL DOCKET NO.

CO-28A Inui an r'oi nt.

UNIT No.3 DATE D c +er 4. 1978 COMPLETED BY S. S. Zulla r

TEL EPilONE 914-739-8200 MONTil Nove+ r DAY AVER ACE DAILY POWER LEVEL

. DAY AVERACE DAILY POWER LEVEL (MWe. Net)

(MWe Net) d

I 953

' 17 951 955 gg 2

3 4"

19

^^

957 20 961 4

959 960 5

21 6

"4 22 947 939 23 OA4 7

g can 24 oc, oc' 25 964 l

9 l

824 964 10 26 gg 27 aee act 962 966 12

, 28 13 29 966 962 964 965 14 30 15 65 31 964 16 INSTRUCTIONS On this fonnst. list the average daily unit power level in MWe. Net for each day in the reporting inonth. Compute io the nearest whole negwatt.

(9/77)

O e.

t

t 50-286 DOCKET NO.

UNITSIIUTDOWNS ANDPOWER REDUCTIONS Indaan Point unit 3 UNIT NA3f E DATE 12/4/78 COMPLETED BY S.

S.

7.u 11 a REPORT MONT11 nnt nebu TElli'llONE

'J 14 -7 V)-a 200 w

=

c

.$ ?

}

$ E3 Licensee E t,

{"',8 Cause & Conective No.

Date g

3g jg&

Event p

r).

Action to gO Prevent Recurrence y

5 3gg Re,ourt 2r mU H

o v

a 19 781110 F

0 A

1 IJA Illi Pump XX Oil leak on pump control system.

Fixed oil Acak.

B j

.g 6

l l

T i

2

~.3 4

F: Forced Reason:

Method:

Exhibit G Instructions

{

S: Scheduled A Equipment Failure (Explain) 1 Manual for Preparation of Data B41aintenance o(Test 2 Manual Scram.

Entry Sheets for Licensee C. Refueling 3 Automatic Scram.

Event Report (LER) File (NUREG-D. Regulatory Restriction 4-Other (Explain) 0161)

E-Operator Training & License Examination F Administrative 5

G-Operational Error (Explain)

Exhibit I Same Source (9/77) 11-01her (Explain)

(

4

..- ".....,,.,"r

W __ _

I

. -.. ~

i. ---

z. - -.

l.

HOtiTitLY I & C CATEGORY X REPORT I

l NoveuJier 1978 i

i f

Month i

1 5

Corrective Action l

Malfunction l

Date l

W.R.

8 Equipment a

1.1/2/78 I&C-I-00023-02 FC 436 RC low flow Chatters near trip setpoint Problem traced to faulty f

regulation cord in sola bistable transformer for instrument bus 11/2/78 I&C-I-00024-02 FC 416 RC low flow Chatters near trip setpoint Problem traced to faulty regulation cord in sola trans-bistable former instrument bus e

11/15/78 IEC-I-00092-02 PT-1025 vent header system Controls for either zero press-Straightened input linkage end recalibrated 1

ure or full pressure I

11/3/78 IEC-I-00176-02 R/I box TM140 VCT outlet Meter indication was erratic Found filter capacitor C5 blown, replaced, recalibrated I

temp.

^

7 t

t 1

i e

l

./

i I

1 i

k

!!C!iTilLY !%I!JTL!!A! ICE RI:PCRT t;otended 1970

. nth t>;T E.

U.R.

EQUIP!4E!;T f1AIEU!1CTIO!3 CORRECTIVE AC. ION 11-13 I-377-02 PCV 1215A Adjust Limit Switch Adjust Limit Switch 11-13 I-370-02 PCV 1216A Repair loose wire connection Repaired loose wire 11-2 I-387-02

  1. 33 Charging Pump Pepack Repacked (replaced packing and parts) 11-20 I-397-02
  1. 32 Instrument Air Inspect valves Removed and repalced inlet and discharge valves Compressor 11-24 I-400-02
  1. 31 charging pump Repair pump suction and Replaced #2 discharge valve, valie discharge valves seat, spring, valve guide, and all cylinder head gaskets 11-27 I-401-02
  1. 32 charging pump Inspect piston packing - renew Replaced all packing on all cylinders e