Environ Assessment & Finding of No Significant Impact Re Proposed Amend 13 to R-75 Increasing Authorized Power Level from 10 Kw to 500 Kw & Allowing Possession of SNM
ML20062F099
Person / Time
Site: Ohio State University
Issue date: 11/05/1990
From: Weiss S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20062F064 List:
References
NUDOCS 9011270087
Download: ML20062F099 (9)


Text

.

l l

4 Lj 7590-01 l

UNITED STATES NUCLEAR REGULATORY COMMISSION i

ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT ENVIRONMENTAL IMPACT REGARDING PROPOSED POWER ~1NCREASE OF

\\

['CILITY OPERATING LICENSE NO.- R.

OHIO STATE UNIVERSITY-i DOCKET NO. 50-150 The U.S. Nuclear Regulatory Comission (the Commission) is considering -

issuance of an amendment to Facility Operating License No. R-75 to the Ohio-State University (the licensee) for the Ohio. State University Pool-Type Research Reactor (05URR) located on the Ohio State University campus in Columbus, Ohio.

ENVIRONMENTAL ASSESSMENT This environmental assessment relates-to the proposed power increase for ths. OSURR at Columbus, Ohio, in response to an application from the licensee of October 7, 1987, as supplemented on May 26, 1989 Febr_uary 28, and June 12, 1990. The proposed action would authorize-operation at'a power level of 500 kilowatts (thermal) (kW(t)), from the presently licensed power level of.10 '

+

kW(t). The only hardware modifications that are required by the power increase i

and that change the environment are those necessary to increase the capacity of.

-the heat removal system and to increase the-coverage of the radioactivity monitoring system, along with their associated instrumentation and controls.

The heat removal system uses primary (pool water)-to-secondary-(ethylene glycol and water mixture) coolant, heat:exchangers, a fan-forced' air cooling unit (also jy[E$bbkbObb e

a

.t.

u called a drycooler) for initial cooling of the secondary coolant, and a city water-based heat exchanger for additional cooling of the secondary coolant.

The primary secondary coolant loop is a totally enclosed and self-contained loop.

No liquid effluent releases are expected from normal OSURR operation.

Any release of water f rom the reactor pool or seconoary coolant fluid from the cooling system will be planned and controlled, and performed in accordance with appropriate regulations.

By including a drycooler in the secondary loop, the OSURR avoids the use of a cooling tower. Thus, the drycooler produces no drift i

or fog and does not use city water. Makeup water for the reactor pool is obtained from tne city water supply, after first passing through an initial cletnup demineralizer. All connections to the city water system will have backflow preventers to preclude the possibility of introducing reactor pool water to the potable water supply. The city water-based supplementary heat exchanger will draw water from the city wcter supply, but it will be used only when tbt outdoor drycooler is unable, because of the outdoor air temperature, to reduce secondary coolant temperatures to the point where primary coolant temperature returned to the pool is within specified limits.

Thus, water use by the supplementary heat exchanger will be monitored and kept within thermal limits for discharge to the sanitary sewer system.

Installation of the outdoor drycooler unit will require very litt10 land because the unit is mounted on an B foot by 17 foot concrete pad, on en unused part of the grounds of the reactor building. Thus, no additional land use will result. To install-the cooling unit, the licensee will not need to remove trees or move animc1 life.

In addition, the cooling unit stands about 48 inches tall, and covers an area of about 8 feet by 14 feet, and thus will cause no disruption of visibility or visual distraction in the area. Operation of the fans of the drycooler will l

cause a small amount of noise, but no more than may be expected from a building air conditioner of modest size.

In any case, the nearest residences are about one quarter of a mile upwind of the reactor building, and persons in and near these areas will not experience any additional noise exposure because of fan operation. The environmental effluents (warm air / caused by increasing the power to 500 kilowatts are negligible.

The licensee plans to expand the radioactive monitoring system by install.

ing additional monitors outside the restricted area. At least four of these monitors will be positioned in the unrestricted area about 100 feet from the reactor building. The areas are normally unoccupied in all directions except about 150 feet to the south where a van de Graaff laboratory is located.

The effect on the environment of these monitors is nigtigible.

Need for the Proposed Action The licensee is planning to conduct research in neutron activation analysis, boron neutron capture therapy, and related medical and biological research, materials analysis, and instrumentation research and testing.

Operation at 10 kW would not provide sufficient neutron flux to conduct these activities.

Environmental Impact The OSURR operates in a shielded pool of water inside the reactor building on the Columbus campus of the Ohio State University. This licensing action does not lead to a change in the physical environment except for the heat removalsystemandradioactivitymonitoringsystempreviousIydiscussed.

Based on the review of the facility specific operating characteristics that are considered for possible effect on the environment, as set forth in the staffssafetyevaluationreport(SER)(seeSERforAmendmentNo.13tofacility m

i i

)

i 4-Operating License No. R 75) for this action, the staff concludes that increasing the power level to 500 kW at OSURR will have an insignificant environmental effect. Although the proposed operating features are judged to have an i

insignificant effect on the environment, the following paragraphs summarize those features with the greatest possible environmental effect.

Argon-41, a product from neu' tron irradiation of air during operation, is the principal airborne radioactive effluent from the OSURR during routine operations. Conservative calculations by the staff, based on the total amount of Ar 41 released from the reactor during the year, place the maximum credible j

dose assessment to members of the general public in areas that would normally be occupied at about 0.2 millirem per year.

The staff has considered hypothetical credible accidents at the OSURR and has concluded that there is reasonable assarance that such accidents will not release a significan', quantity of fission products from the fuel cladding and, therefore, will not :ause significant radiological hazard to the environment or the public.

This conclurion is based on the following:

1)

The txcess reactivity available under the technical specifications is ir..uf'icient to support a reactor transient generating enough

~

en',rgy to ;ause overheating of the fuel or loss of integrity of tiie claWti g.

l 2)

At a thermai Jower level of 500 kilowatts the inventory of fission 3roductsintiefuelcannotgeneratesufflcientradioactivedecay t

1 eat to cause fuel damage even in the hypothetical event of instantaneous tota! loss of coolant, and 3)

Thehypotheticallossofintegrityofthecladdinhofthemaximum irradiated fuel rod will not lead to radiation exposures in the unrestricted environment that exceed guidelines values of 10 CFR Part 20.

e.

-y--,-

-.,e..

.-,i.----

t

.v v-

-,e p

-+g-.we-ar

=

pw.,

+

e i t

t In addition to the analyses in the SER summarized herein, the environmental effect associated with the operation of research reactors has been generically evaluated by the staf' and is discussed in the attached generic evaluation.

This evaluation concludes that there will be no significant environmental effect associated with the operation of research reactors licensed to operate at power levels up to and including 2 MW(t) and that an environmental impact statement is not required for the issuance of construction permits or operating licenses for such facilities. We have determined that this generic evaluation is applicable to operation of the OSURR and that this facility will have no special or unique 3

features that would preclude reliance on the generic evaluation.

Alternatives to the Proposed Action Alternatives considered to the proposed action were to not increase the power level or to increase the power level to some lesser power. Operation at i

10 kW would not achieve the licensee's research objectives. Operation at a lesser power could achieve some but not all of the objectives and would result in essentially the same environmental effect as at 500 kW. Tha environmental effect between operation at 10 kW and at 500 kW is not significant.

Alternative Use of Resources This action does not involve the use of any resources beyond those normally allocated for such activities.

Agencies and persons Consulted The staff has obtained the technical assistance of the Idaho National Engineering Laboratory in performing the safety evaluation of continued operation of the OSURR facility.

. ~. - -..

\\

FINDING OF NO $1GNIFICANT IMPACT Based upon the foregoing environmental assessment, the Cornission has concluded that the proposed action will not have a significant effect on the quality of the human environment. Accordingly, the Comission has determined not to prepare an environmental impact statement for this proposed action.

For further details with respect'to this action, see the licensee's request for a license amendment of October 7,1987, as supplemented on May 26, 1989, February 28 and June 12, 1990. These documents are available for public inspection at the Comission's Public Document Room, 2120 L Street, N.W., Washington, D.C.

20555.

Dated at Rockville, Maryland this 5th day of November 1990.

FOR THE NUCLEAR,qEGULATORY COMMISSION Seymour H. Weiss, Director Non-Power Reactor Decommissioning and Environmental Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation I

l

i

[NVIRONMENTAL CON $!DERATIONS REGARDING THE LICEN$1NG OF j

s l

RESEARCN REACTOR $ AND CRITICAL FACILITIES i

h Introduction This discussion deals with research reactors and critical facilities which are designed to operate at low power levels, 2 HW(t) and lower, and are used primarily for basic research in neutron physics, neutron radiography, isotere prodcction, experiments associated with nuclear engineering,ilities willtraining and as a l

part of a nuel, ear physics curriculum. Operation of such fac generally not exceed a 5-day week, 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> day, or about 2000 hours0.0231 days <br />0.556 hours <br />0.00331 weeks <br />7.61e-4 months <br /> per year.

l Such reactors are located adjacent to technical service support facilities i

cith convenient access for students and faculty.

Sited most frequently on the campuses of large universities, the reactors are usually housed in already existing structures, appropriately modified, or placed in new buildings that are designed and constructed to blend in with i

existing facilities. However, the environmental considerations discussed herein are not limiteri to those which are part of universities.

)

Facility There are no exterior conduits, pipelines, electrical or mechanical structures or transmission lines attached to or adjacent to the facility other than for utility services, which are similar to those required in other similar facilities, specifically laboratories. Hiet dissipation, if required, is generally accomplished by use of a cooling tom:* located next to or on the ecof of the building. These cooline towers typicatif are on the order of 10' x 10' x 10' and are comparable to' cooling towers associated with the air-conditico;n; tysterns of large office buildings. Heat dissipation may also be accomplished by traecfer through a heat exchanger to water flowing directly to a sewer or a chilled water system. Make up for the cooling system is readily available and usually obtained from the local water supply.

Radioactive gaseous effluents are limited to Ar 41 and the release of radioactive liquid effluents can be carefully monitored and controlled. Liquid wastes are collected in storage tanks to allow for decay and monitoring prior to dilution and release to the sanitary sewer system.

This liquid waste may also be solidift.ed and disposed of as solid waste Solid radioactive wastes are packaged and ship >ed off-site for-storage at htC approved sites. The transportation of suci waste is done in accordance with existing NRC-D0T regulations in approved shipping containers.

Chemical and sanitary waste systems are similar to these existing at other similar laboratories and buildings.

l 1

~. _ ~. _,. _. _. _ _ _ _ _..

~ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _. _

Environental Effects of Site Preparation and Facility Construction I

Construction of such facilities invariably occur in areas that have already been disturbed by other butiding construction and, in some cases, solely crithin an already existing building. Therefore, construction would not be expected to have any significant effects on the terrain, vegetation, wildlife or nnarby waters or aquatic life. The societal, economic and esthetic impacts of construction would be no greater than those associated with the j

construction of a large office building or similar research facility.

I Environmental Effects of Facility Operation l

Release of thermal effluents from a reactor of less that 2 W(t) will not have a i

significant effect on the environment. This'small amount of waste heat is generally rejected to the atmosphere by means of small cooling towers.

Extentive drift and/or fog will not. occur at this low powar level. The small amount of waste heat released to sewersIll not raise average waterin the case of hea secondary flow directly to the sewer, w temperatures in the environment.

Release of routine gaseous effluents can be limited to Ar-41, which is generated by neutron activation of air.

In most cases, this will be kept as low as l

practicable by using gases other than air for supportina experiments.

Experiments that are supported by air are designed to mInimite productior, of

~

Ar-41. Yearly doses to unrestricted areas wil be at or below established guidelines in 10 CFR 20 limits. Routine releases of radioactive liquid 1

effluents c n be carefully monitored and controlled in a manner-that will ensure compliance with current standards.

Solid radioactive wastes will be shipped to an authorized disposal site in appro,*ed containers. These wastes should not require more than a few shipping containers a year.

I Based oii experience with other research reactors, soecifically TRIGA reactors

.operatira in the 1 to 2 W(t) ranje, the annual releese of gaseous and liquid effluentr to unrestricted areas siould be less than 3V curies and 0.01 curie, respectively.

No release of potentially harmful chemical substances will occur during normal operation. Small arounts of chemicals and/or high solid content water may be released from the facility through the sanitary sewer during periodic blowdown of the cooling tower or from laboratory experiments.

Other potential effects of the facility, such as esthetics, noise, societal or impact on local flora and fauna are expected to be too small to measure.

invironmental Effects of Accidents Accidents ranging from the failure of experiments up to the largest. core damage and fission product release considered possi>1e result in doses that are less than 10 CFR Part 20 guidelines and are considered negligible with respect to the environment.

l I

j

/

e l

l l l

i unavoidable Effects of Facility Construction and Doeration The unavoidable effects of construction and operation involve the materials ssed in construction that cannot be recovered and the fissionable material l

Wsed in the reactor. No adverse impact on the environment is expected from i

either of these unavoidable effects.

Alternatives to Construction and Doeration of the Facility To acconplish the objectives associated with research reactors, there are no i

suitable alternatives.

Some of these objectives are training of students in the operation of reactors, production of radioisotopes, and use of neutron and gamma ray beams to conduct experiments.

(

Leno Term Effects of Fagility Construction and Coeration The long term effects of research facilities are considered to be beneficial as a result of the contribution to scientific knowledge and training. Because of the rrla*.ively small amount of capital resources involved and the small 4

.ithpact r,n the environment, very little irreversible and irretrievable corraittent is associated with such facilities.

Costt and Benefits of Facility Alternatives The costs are on the order of several millions of dollars with very little environmental impact.

The benefits include, but are not limited to, some combination of tie following:

conduct of activation analyses, conduct of neutron radiography, training of operating personnel and education of students. Some of these act'vities could be conducted using particle accelerators or radioactive sources which would be more costly and less efficient. There is no reasonable alternative to a nuclear research reactor t

l for conducting this spectrum of activities.

Conclusion The staff concludes that there will be no significant environmental ispect associated with the licensing of research reactors or critical facilities desianed to operate at power level of 2 MW(t) or lower and that no environmental impact statements are required to be written for~the issuance of construction permiu or operating licenses for such facilities.