KANSAS GAS ANI) ELECTRIC COMPANY 1 4 E LE C f 54C COMP ANY OLENN L ROESTER v<a pas tiormt mut.tean August 5, 1982 Mr. liarold R. Denton, Director Gffice of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 KMLNRC 82-229 Re Docket No. STN 50-482 Ref:
(1) Letter KMLNRC 82-182 dated March 26, 1982 from GLKoester, KG&E, to HRDenton, HRC (2) Letter KMLNRC 82-192 dated May 3,1982 from GLKocster, KG&E, to HRDenton, NRC Subj: Additional Information
Dear Mr. Denton:
Kansas Gas and Electric Company representatives met with the NRC on March 19, 1982. Discussions were held concerning the effects of a higher free field response spectra prepared for the NRC (NUREG-0881, Appendix E) on those Wolf Creek site specific, Category I structures and components which were designed to a Regulatory Guide 1.60 response spectrum anchored at.12g.
Reference (1) transmitted an analysis of the effects of the higher spectrum on the ultimate heat sink dam and slopes.
Reference (2) transmitted a similar analysis for the essential service water system (ESWS) pumphouse, manholes, valvehouse, discharge structure and pipe incasements.
Transmitted herewith is the evaluation of the effects of the higher spect. rum on the essential service water piping systems and supports.
These analyses have shown that the existing design for the site specific Category I portions of the Wolf Creek Plant have sufficient design con-servatism to accommodate a 0.15g SSE event with minimal, if any, redesign.
Accordingly, and in the interest of resolving the seismic issues in the Wolf Creek SER, KG&E commits to adopting a Regulatory Guide 1.60 spectrum anchored at 0.159 (zero period acceleration) as the SSE design spectrum for the site specific, Category 1 structures and components at the Wolf Creek Generating Station. This spectrum closely bounds the site specific go l
o 8208100339 820805 PDR ADOCK 05000402 A
PDR 201 N. Market - Wichita, Kansas - Mail Address: PO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 261-6451
Mr. Harold R. Denton KMLNRC 82-229 August 5, 1982 response spectrum given in NUREG-0881, Appendix E which was proposed by Lawrence Livermore National Laboratory.
The only analysis of the Wolf Creek design not yet provided to the NRC for the higher SSE loading is the effect on qualification of equipment to withstand the higher loads. KG&E's commitment above, of course, includes such qualification to the 0.15g SSE level. Documentation of the seismic qualification of the ESWS equipment will be available for review with other equipment qualification information when the NRC conducts the SQRT audit of Wolf Creek.
This information will be formally incorporated into the Wolf Creek Geh-erating Station, Unit No.1, Final Safety Analysis Report in Revision 10 This information is hereby incorporated into the Wolf Creek Generating Station, Unit No.1, Operating License Application.
Yours very truly, sfg)
I/S GLK:bb Attach cc: Mr. J.B. Hopkins (2)
Division of Project Management Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Mr. Thomas vandel Resident NRC Inspector Box 311 l
Burlington, Kansas 66839 4
l l
L
OATI! OF AFFIPJtATION STATE OF KANSAS
)
) SS:
. COUNTY OF SEDGWICK )
4 I
I, Glenn L. Koester, of lawful age, being duly sworn upon oath, do depose, state and affirm that I am Vice President - Nuclear of Kansas Gas and Electric Company, Wichita, Kansas, that I have signed the foregoing ' letter of transmittal, know the contents thereof, and that all statements contained therein are true.
KANSAS GAS AND ELECTRIC COMPANY
~
By - Glenn L. Koester ~ dJA 24()
M Vice President - Nuclear W.B. Walker, Secretary l
4 STATE OF KANSAS
)
) SS:
COUNTY OF SEDGWICK )
BE IT REMEMBERED that on this 5th day of _ August, 1982
, be fore me, Evelyn L. Fry, a Notary, personally appeared Glenn L. Koester, Vice l
President - Nuclear of Kansas Gas and Electric Company, Wichita, Kansas, who is personally known to me and who executed the foregoing instrument, and he duly acknowledged the execution of the same for and on behalf of and as the act and deed of said corporation.
,IN WITNESS WHEREOF, I have hereunto set my hand and affixed my seal the
' ',,,,,,,,gl'Ets,,and year above written.
R
/
- h .
a:
l k,
M y gi,Cf ~ I
-[Evelyni. Fry, N ary
- T,.,
e, i I
e'
' " My C6'mmission expires on August 15, 1984.