Responds to NRC Re Violations Noted in Insp Repts 50-277/78-21 & 50-278/78-26.Corrective Actions: Computer Analysis Method Modified to Calculate Incremental Pu-241
ML20062B761
Person / Time
Site: Peach Bottom  
Issue date: 10/02/1978
From: Daltroff S
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Martin W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20062B758 List:
References
NUDOCS 7811010089
Download: ML20062B761 (2)


Text

.

l PHILADELPHIA ELECTRIC COMPANY 2301 M ARKET STREE.T P.O. BOX 8699 PHILADELPHI A. PA.19101 SHIELDS L. D ALTRoFF suc%c'ZEEE.-

October 2, 1978 Re:

Docket Nos.:

50-277 50-273 Inspection Nos.:

50-277/78-21 50-278/78-26 Mr. Valter G. Martin, Chief Safeguards Branch United States Nuclear Regulatory Commission Region 1 631 Park Avenue King of Prussia, PA 19404

Dear Mr. Martin:

Your letter of September 18, 1978 forwarded Inspection Report 50-277/78-21 and 50-273/79-26.

Appendix A to your letter addresses one activity which did not appear to be in conformance

\\

with Nuclear Regulatory Commission requirements.

This item is a Deficiency and is listed below with our response.

Section 70 53 (a) states in part "Each licensee who is authorized to possess at any one time and location special nuclear material in a quantity totaling more than 350 3 rams of contained uranium-235, uranium-233, or plutonium or any combination thereof, shall comple te and submit to the Commission Material. Status Reports on Form NRC-742, in accordance with printed instructions for completing the form, concerning special nuclear material received, produced, possessed, transferred, consumed, disp 9 sed of or lost by the licensee."

The Printed Instructions for completing the Form NRC-742 state in part, the f ollowing instructions for Line 72-Decay: " Enter the amount of radioactive decay which occurred during the reporting period for Plutonium and

.'2.01 OOQ

.s-

$r. Walter G.

Martin Page 2 October 2, 1978 Pu-238, when SNM being reported is p lu t o n i'sm, enter the amount of radioactive decay of the Isotope Pu-241 if the decay is 1 gram or more."

Contrary to the above, Material Status Reports submitted for the periods ending March 31, 1977, September 30, 1977, and March 31, 1978 were not completed in accordance with the printed instructions in that the amount of radioactive decay of plutonium during these periods was not reported on the Form SRC-742, and the inspectors verified the Pu-241 decay 3 to be, in fact, greater than 1 gram fee each uf the above NRC-742 reporting periods.

Response

Total Plutonium-241 decay during all prior Material Status Report (Form NRC-742) periods, as well as the report period ending September 30, 1978, will be determined and reported on line 72 of Form NRC-742 due te be transmitted for the period ending September 30. 1978.

  1. To prevent a, recurrence, in-house isotopic computer analysis methods are being modified to provide an automatic calculation of incremcatal Plutonium-241 decay during each subsequent six month report p e r io d... This decay will be reported on line 72 of each Material Status. Report transmitted subsequent to the S e p r.amb e r

~

30, 1978 report.

~

Very truly yours, l

4 e"

A

,