Text
,
c
,7
'l l.:o I
- Amersham corporation?
40' North' Avenue :
Burlington, Massachusetts 01803 Telephone (617) 272-2000 '
19 October =1990 i Mr. Charles-MacDonald, Chief 1
Transportation Branch Division of Safeguards and Transportation, NMSS j
U.S. Nuclear Regulatory Commission j
OWFN, 4E4-l Washington,:D.C.
20555 j
q
Dear Mr. MacDonald:
j l
I have. enclosed lthe additional information you requested concern-i ing docket number' 71-9141.
.4 Item'Sc has-been corrected to USA.
Item 10 refers to the DOT labels, i.e.
Yellow-II or Yellow III that.are placed on the shipment, and are described in table 1 in
~
q the instructions.
Item 6 refers to the permanent metal name-plates lthat are attached to the package and are - designed-to withstand the. fire test of Part 71.
The-instructions have been revised to clarify the shipping of a j
. package:within a crate, i
In Section 7-.3, the instructions for shipping an empty package i
have1been revised-to require a physical verification that the container!is empty prior to shipment.
-The instructions ~have been cl'rified to. indicate the shipping of-a ca package or a package within an overpack.
'A' note has been added to-clarify that the shipment is not exempt ifromLall requirements of part 49 CFR 171-177.
i i
i I
/' )
9010230285 901019 P
~= 1 Amersham 1
.:an
i V:
ll
'e D
Mr. MacDonald, Chief, Page_Two of two.
These changes have been ' submitted as revised.x ages.
I trust this provides the necessary information to' complete the review of:our-renewal request.
t.
Please contact me if you require additional'information.
~
Sincerely, T fh',9 k)il$(11 t'][1ll
- t Cathleen M. Roughan Radiation Safety Officer-4 CMR/bt i
[-
't
}.'-
,f 1,
f 45 I'
l '
i i --
ll l
i 2
e
~
4 t
i
.i.
SECTION 7:- MODEL 900 OPERATING' PROCEDURES-t NOTE:
All the precautions'used when making e. radiographic expe-sure must be observed when loading or when unloading the package.
l
-1.
A= calibrated and' operable survey meter must.be used at all' times when; loading or unloading this' package.
2.
LPersonnel dosimetry must be worn-when loading or unloading the package.
3.
For' details'on the operation and source changing procedures please refer to the instruction manual'for the device which can be;obtained.from Amersham Corporation.
~
\\
u
\\
TECHNICAL SPECIFICATIONS l
MODEL 900 EXPOSURE DEVICE USNRC Type B Certificate USA /9141/B(U)
=
Isotope
=
Capacity.
100 Curies-(+20%)
=
Authorized source assembly.
90003
=
7 Gross Weight 44.lbs (20 kg)
=
Shielding
-Depleted Uranium
=
29 lbs '13 kct) r 6
7-1 Revision 1 October 1990
y y. )
t a.
9
'I 7.1 Procedure For Loadina'the Packace t
3
-y
.1 1.-
Assure that;the package is not' damaged..except for-j superficial marks or dents.
~
^
2..
Assure: the sourceL is authorized f or use' in this" container'and is secured in the, locked position.
3.
,To properly; secure the source, the' selector ring should be in the lock position, the dust cover-l must be installed and the key lock must be-de'-
pressed with the key' removed.
4 '.
Install'.the shipping plug securely and apply _a, security seal with an identification mark through
'the shipping, plug and front nut of the camera.-
s 5.
Assure all_ nameplates are clear and leg'ible and containlthe following information..-
a.
The words " Danger Radioactive Material" and the trefoil symbol.
L b.
The proper shipping name l;
Radioactive Material Special' Form, N.O.S.,
UN2974-l c.
Package identification LUSA/9141/B (U), Type B (U) -
d.
The radioactive contents.
L 6.
If the shipping package is.to be packaged inside a crate or other outer packaging, the_ outer packag-ing.must be strong enough_to withstand the normal conditions.of-transport and'must not reduce the--
L safety of the package.
The-shipping package'must L
be: placed within the. outer package :with sufficient l
blocking to prevent shifting during transporta--
L tion.
NOTE:
When using a-crate or other outer packaging'to ship the 900, steps 7-13 refer to the. crate or outer packaging.
p.-
i
((
t l
l l
I 7-2 Revision 1 L
October 1990
- b
, il.
i 17. :
Survey the, exterior surfaces of the package and k
assure that the: maximum radiation level does-not
~
exceedf200 arem/hr;.
Survey. one meter from thel i
exterior surfaces ofLthe' package'and. assure-that the-maximum--radiationilevel does not exceed 10 L<
'arem/hr.
Determine the proper:shippingolabelsito i
be appli'edito the package using the.-criteria of;
. table 1.
1 L
8.
Properly complete two shipping: labels:' indicating.
the contents (Iridium-192),. the activity) of the t
L source in curies'or-millicuries and the, transport index.
The transport index is the dimensionless-
- o number (rounded up to the
- first -decimalt place) expressing the maximum' radiation ;1evel '(in f
arem/hr) measured at one meter from the package surface.
l 9.
Assure-that any old shipping labels'have-been L
removed from the package.
Apply two properly
. completed labels to two opposite sides.of.the package.
10.
Mark the outside of the package with'the proper shipping name and identificationonumber (Radioac--
tive Material, Special Form, n.o.s., UN 2974) if1
-not already marked.
Place the> letters RQ next to.
^
the proper shipping name.-
l 11.
If the: shipping package is inside a crate or other' outer packaging, mark the-outside package:"INSIDE PACKAGE COMPLIES WITH PRESCRIBED SPECIFICATIONS"'
and list the-appropriate DOT specification number or USNRC Type B number and the.words " TYPE B".
12. - Assure that the: levels of removable-radioactive contamination'on the outside surface of the outer package do not exceed 0.001 microcurie per 100-s square centimeters.
13.
Properly complete the shipping papers, indi'cating:
a.
Proper shipping name and identification number (i.e. Radioactive Material,-Special Form, n.o.s.,'UN 2974).
b.
The letters RQ must appear next to the proper shipping name when shipping more than-10 curies of Ir-192 or Co-60.
7-3 Revision 1 October 1990 i
w-er-
..y-fi c.
Name'of the radionuclide-(i.e. iridium-192).;
d.
Activity of source in curies or' millicuries.-
e.-
Category of label applied;(i.e.. Radioactive Yellow II).
f.
Transport Index.
g.
USNRC identification number or DOT'specifica-
' tion number (i.e. USA /9141/B(U).
For export shipments, the IAEA identification-h.
number (i.e. USA /9141/B(U).
i.
Shipper's certification:
"This is to. certify that the above named materials are-properly classified, described,.
packaged, marked and labeled and.are-in proper condition'for transport according=to the applicable regulations of the-Department of Transportation."
j.
The' shipping papers must. indicate an emergen-
.cy phone number.
This phone number must have 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> coverage.in case: of an - emergency.
concerning your shipment.
The' phone-number must be clearly visible on the~ shipping paper.
k.
For packages containing depleted uranium as shielding material, a notice must be enclosed' in or on the package, included with the packing list or otherwise-forwarded with the
-package.
This notice must include the'name of~the consignor or consignee and the state-ment:
"This package conforms _to the conditions and limitations specified in 49 CFR173.424 for excepted radioactive material, articles manufactured from depleted uranium UN 2909.
14.
Place the package onto the vehicle using the handle of the camera.
15. - Properly brace and secure the package against movement in the vehicle.
1 7-4 Revision 1 October 1990
L o'
16.: ' Assure that"back of the' vehicle is closed.and secured so that it will not open-during. transport.;
NOTES: l '.
Forl air:
shipments, the following-Shipper's certification may be used:
"I hereby certify that-the contents of'~the-consignment are fully-land accurately de-scribed,above by proper: shipping name-and-are classified packaged,. marked and labeled and are in proper condition for carriage by air according to applicable national': gov _-
ernmental regulations."
2.
For air shipments, the package must-bec
-labeled with a " CARGO AIRCRAFT ONLY"' label.
-and the shipping papers must state:'
"THIS SHIPMENT IS WITHIN THE LIMITATIONS PRESCRIBED FOR CARGO AIRCRAFT ONLY".
3.
-For international shipments the activity must be given in Gigabecquerels'on'the1 DOT label and the shipping papers ~ (curies: X ' 37
= Gigabecquerels).
-t e
l 7-5 Revision 1 October 1990 a
~
~
A t
-l
[,,
1 I
J7.2 Procedure for Unloadina-the Packaae NOTES: a.
-A radioactive material package must be' accepted from the' carrier at the time it is delivered.
b'.
. If - a radioactive material package is_to be held at i
the carrier's terminal for pickup, arrangements must J
be made to receive notification from-the carrier of J
'the arrival _of the package at;the time of arrival.
.The_
package ~must be picked = up expeditiously upon
' receipt of notification (within-three hours
- if-j practicable).
1.
Upon receipt of a package of radioactive material, survey the exterior surfaces of.the package.and assure that the maximum radiation level does not-exceed 200 mrem /hr.
Survey three feet from the exterior surfaces of'the packages'and-ascitre that the maximum radiation level does not exceed 10 l-mrem /hr..'If either of these limits are exceeded, notify.the Radiation Safety' Officer immediately.
Record - the maximumi i
L radiation levels measured.at the package surface and at-l' three feet from the. package surface on the-Receiving Report.'
t.
h 2.-
If the package contains radioactive material which is'notiin l
special form make a contamination wipe test of the exterior-L surface of-the package.
Wipe a representative surface of
.i the package, covering an area of approximately 100 square-l.
centimeters,.using a cloth patch and moderate-pressure.
Measure the activity _of the patch using the contamination ll monitor and. assure that the activity-does not exceed-0.01 L
microcurie.
If this limit is exceeded, notify the. Radiation 1
Safety Officer immediately.
Record the results of this contamination' wipe-test'on the Receiving Report.
NOTE:
If any of these limits are exceeded, the Radiation c
Safety Officer shall immediately notify the USNRC and l
the final delivering carrier.
q
~
3.
Inspect the package for any evidence of physical damage.
Record the results of this inspection'on the Receiving i
Report.
Also record on the Receiving Report'the source model number, source serial number, radionuclide, activity, transport package model number and package serial number.
Forward a copy of the completed Receiving Report.to the 1
L Radiation Safety Officer.
[
4.
Assure that the package is locked, or place the package'into an outer locked container.
Place the package into the
,p3 Radioactive Material Storage Room and lock the door to the
(;
room.
7-6 Revision 1 October 1990
'y
(
.,l.,,
- q gj
- 1 5 '.
-Keep.a copy of:the operations Manua1-for the package on file to assure;you-have-the' proper opening instructions.
-~
t
. 6.-
To properly open.and use the package,- as a radiographic.
device refer to!the? detailed instruction' manual for this
^
o.- i -
device.'
-i i'
lj q
0
,I-1 1
.ii 4
4
]
-i
't
+
t
?
l i
)-
7-7 Revision 1 October 1990
+
s
- 4
.7.3 Procedure for Preparation of an'Emnty Packace for t
Transoort 1
i 1
1.
. Assure'.that theipackage does not contain=a radio.
active source,-'by performing the:following proce--
' dure:'
3 a.-
Survey the device-to assure radiation--levels:
do not exceed approximately 2 mR/hr at thet surface.-
- )
3 b '.
Due to the. straight source tube of the 900.a il physical verification can be performed-by a;
'I visual' check of the tube, i
o c.
Remove the shipping plugs at both ends of the j
camera'and assure there is no connector'in the lock assembly.
Visually verify there is'
?
no source within the tube.
4 d.
'Once the camera-is-determined to be empty,-
insert the shipping plugs and seal wire the front shipping plug.
Attach an empty-tag to-i the device and prepare the package for ship-
[
' ment based on the radiation levels-obtained-below.
2.
If the shipping package is to be-'placed-inside a crate or other outer packaging, the outer.packag-ing,must-be strong.enough_to withstand the normal
,r conditions of transport and must not reduce the-
-j safety of the-package.
The shipping' package must j
be placed within the outer package with sufficient' blocking to prevent' shifting during-transporta-tion.
NOTE:
When using a~ crate or other outer-packaging'to ship the 900, steps 3-4 refer to the outer packaging.
3.
Assure that the levels of removable radioactive contamination on the outside surface'of the-outer package do not exceed 0.001 microcurie per-100 square centimeters.
1 7-8 Revision 1 October 1990
,d'
- 4.
Survey.the: package at the surf ace and at one meter
.from tht surface-to determine'the proper shipping
-labels to be applied to package.=
-a.
IfDthe-surface radiation levelfdoes not-exceed 0.5 arem/hr and there is no' measurable radiationLlevel at one meter-from the sur-face, no label.is required., Mark the outside.
of the; package-with the proper shipping'nameE and identification. number (Radioactive Mate ~
rial,. Articles Manuf actured ' from ' depleted Uranium,-UN 2909).and the statement " EXEMPT-.
.FROM SPECIFICATION PACKAGING SHIPPING. PAPER AND CERTIFICATION, J MARKING AND LABELING 'AND EXEMPT FROM THE REQUIREMENTS OF _49CFR part 175 PER CFR173.421-1 AND,49 CFR173.424".
~ NOTE: This-does not exempt the, shipment-from the reporting requirements listed-in 49 CFR parts-171-177 pertaining to the reporting of--.the-contamination or'other radiation incidents.
Additionally, a notice must be enclosed in or on the package, included with the packing list or otherwise forwarded with the package.
The notice must-include the name of the consignor or consignee and the statement:
"This-package conforms to the conditions and limitations 'specified in 49CFR173.424 for Exempted Radioactive. Material, Articles Manufactured from Depleted Uranium,oUN 2909".
b.
If the surface radiation level exceeds-0.5 mrem /hr, or.if there is a measurable radia-tion level at one meter from-the surface,_use' the criteria of table-1-in section 7.1 to determine-the proper shipping labels to be applied to the package.
Mark the outside of-the package with the proper shipping name and identification number -(Radioactive Material,
- LSA, n.o.s.,~UN 2912)..
If the container is packaged inside a crate'or other outer ~ pack-aging, mark the package with-the statement "INSIDE PACKAGE COMPLIES WITH PRESCRIBEC SPECIFICATIONS".
"4 Properly complete the shipping papers, as-i i
listed in section 7.1.
The isotope is U-238 q
and-approximately 5 millicuries.
o 7-9 Revision 1 October 1990 i
'If
pl +
=
s a<
{
s v
.g TABLE 1 t
a
~
4
, s r
.1~
e t
i t
+
+
i t-
,?
r Maximum-Radiation Nevel' 3,_
at Surface at One Meter Radioact ive White I '
0.5 mR/hr None 1
N@A010 ACTIVE 1 l.
a
'h 7 N
j
-t Radioactive Yellow 11 i
f i
50 mR/hr
.1.0 mR/hr 1r RADIOACilVEII/
)
'a lw 7
a i i
Radioactive Yellow III gg i
N 200 mR/hr 10 mR/hr R.AD.IDACilVE Hi U
-.c.
l-l
'r 1;
b l-l^
7-10 Revision 1 p
October 1990 l-'
J.
{
l 9
.