Dear Mr. Bauer:

Subject:

Request for Additional Information - Limerick (Core Performance)

The Reactor Fuels and Reactor Physics Sections of the Core Performance Branch have reviewed the Limerick FSAR and have ident.ified a need for the additional information delineated in Enclosure 1.

Please provide us, within 7 working days from receipt of this letter, with the date(s) on which you plan to respond to the above. Any questions concerning this infortation request should be directed to Dr. Harvey Abelson, (301) 492-9774, the Licensing Project P.anager.

Sincerely, 1

4 i

A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing

Enclosure:

As stated cc: See next page

'1 8208030081 820709 PDR ADOCK 05000

^

'aA.

..../B D

M DL:LI L J or,,c.,

H t

ASch er wRme >

.?N.!82,,,..... ?!..

82.......

om, OFFICIAL RECORD COPY usaponen-us so NRC FORM 318 (10-80) NRCM 0240

.\\-

~'

Lime rick Mr. Edward G. Bauer, Jr.

Vice President & General Counsel Philadelphia Electric Compary 2301 Market Street Philadelphia, Pennsylvania 19101

~

cc: Troy B. Conner, Jr., Esquire Mr. Marvin I, Lewis Conner and Wetterhahn 6504 Bradford Terrace 1747 Pennsylvania Avenue, N. W.

Philadelphia, PA 19149 Washington, D. C. 20006 Frank R. Romano, Chairman Mr. Robert W. Adler Air &-Water Pollution Patrol Assistant Counsel 61 Forest Avenue Commonwealth of Pennsylvania, DER Ambler, PA 19002 505 Executive House P. O. Box 2357 Charles W. Elliott, Esquire Harrisburg, Pennsylvania 17120 ~

Thones & Hair 123 North Fifth Street Honorable Lawrence Coughlin Allentown, PA 18102 House of Representatives Congress of the United States Judith A. Dorsey, Esquire Washington, D. C. 20515 Limerick Ecology Action 1315 Walnut Street, Suite 1532 Roger B. Reynolds, Jr., Esquire Philadelphia, PA 19107 324 Swede Street Norristown, Pennsylvania 19401 Mr. Karl Abraham Public Affairs Officer Lawrence Sager, Esquire Region I Sager & Sager Associates U.S. Nuclear Regulatory Commission 45 High Street 631 Park Avenue Pottstown, Pennsylvania 19464 King of Prussia, PA 19806 Joseph A. Smyth Mr. Jacque Durr Assistant County Solicitor Resident Inspector County of Montgonery U.S. Nuclear Regulatory Commission Courthouse P. O. Box 47 Norristown, Pennsylvania 19404 Sanatoga, PA 19464 Eugene J. Bradley James M. Neill, Esquire s Philadelphia Electric Company Associate Counsel for Del-Aware Associate General Counsel Box 511 2301 Market Street Dublin, PA 18917 Philadelphia, Pennsylvania 19101 Joseph H. White III Mr. Vincent Boyer 11 South Merion Avenue Senior Vice President Byrn Mawr, PA 16801 Nuclear Operations Philadelphia Electric Company 2301 Market Street Philadelphia, Pennsylvania 19101

./

Thomas GenJsky, Director Sugarman & Denworth Bureau of Radiation Protection Suite 510 Dept. of Environmental Resources.

North American Building 5th Floor, Fulton Bank Bldg.

121 South Broad Street Third & Locust Streets Philadelphia, PA 19107' Harrisburg, PA 17120 Donald S. Bronstein, Esq.

Director, Pennsylvania Emergency The National Lawyers Guild Management Agency Third Floor..

Basement, Transportation a 1425 Walnut Street Safety Building Philadelphia, PA 19102 Harrisburg, PA 17120 Lawrence Brenner, Esq., Chairman

  • John Shniper Administrative Judge Meeting House Law Bldg. & Gallery U.S. Nuclear Regulatory Commission Mennonite Church Road Washington, D.C.

20555 Schuykill Road (Rt. 724) l Spring City, PA 19475 Dr. Richard F. Cole

20555 Delaware Valley 103 Vernon. Lane, Box 186 Dr. Peter A. Morris

  • Moylan, PA 19065 Administrative Judge U.S. Nuclear Regulatory Commission W. Wilson Goode Washington, D.C.

20555 Managing Director City of Philadelphia Philadelphia, PA 19107 William A. Lochstet 119 E. Aaron Drive State College, PA 16801

[

Walter.W. Cohen -

Consumer Advocate Office of Attorney General l

1425 Strawberry Square l

Harrisburg, PA 17120 Steven P. Hershey, Esquire l

Consumers' Education & Protective Association Sylvania House Juniper & Locust Streets Philadelphia, PA 19107 Alan J. Nogee The Keystone Alliance 3700 Chestnut Street Philadelphia, PA 19104

J' ENCLOSURE 1 JUN 3 01992 QUESTIONS FOR LIMERICK GENERATING STATION

~

490.1 Since the issuance of NED0-20944, which is referenced in the Limerick FSAR, GE has. developed another fuel design as described in NED0-24011-A-2.

Is the applicant's fuel system design like the new fuel. design (NED0-240ll-A-2)?

If so, provide the information that is needed for the new fuel design.

490.2 The SRP states that allowable oxidation, hydriding, and crud levels should be discussed in the FSAR and shown to be acceptable.

In the past, we have not reviewed these phenomena in accordance with the SRP.

However, in light of (a) recent emphasis on stricter adherence to the SRP, and (t) current

' interest in extended burnups, we request that you provide the following:

(1)

Allowable limits on external ox dation, hydriding, and crud buildup.

(2)

Justification for those limits.

(3)

Evidence that the Limerick fuel will not exceed those limits.

490.3 The SRP Section 4.2 states the need for on-line fuel system monitoring and post-irradiation surveillance.

The FSAR Section 4.2 and NED0-20944 do not have information about on-line fuel system monitoring.

Although Section 2.4l.3 of NED0-209_44 has some information about post-irradiation surveillance, the contents do not follow the SRP guidelines.

Please provide further infonnation on on-line fuel system monitoring and post-irradiation surveillance in accordance with the SRP guidelines.

4-s A safety design basis for the control rod drive system is 491.1 that "each positioning device prevents its control rod from (4.6.1.1)

~

Is this withdrawing as a result of a single malfunction".

to be intrepreted to mean that rod drift occurs only for multiple malfunctions?

Expl ain.

4 1

0 s

e 9

0 e

2

- -.- --.~.. - -... - -