_

]

c.

4 q

August 24, 1990 1

o i

- Docket No. 50 461 DISTRIBUTION

' Docket m e..

EJordan NRC & Local PDRs ACRS(10) l Mr. Frank A. Spangenberg PD33 Reading PD33 Gray File r

Manager. Licensing and Safety DCrutchfield Region III, DRP.

.Clinton Power Station JZwolinski P. 0. Box 678 PKreutzer Mail Code V920 JHickman Clinton, Illinois 61727 OGC-0WFN

Dear Mr. Spangenberg:

SUBJECT:

REVIEW OF RESPONSE TO NRC GENERIC LETTER 88 01, "NRC POSITION ON IGSCC IN BWR AUSTENITIC STttNLESS STEEL PIPING," FOR CLINTON POWER STATION,

{

UNIT 1(TACNO.69130) i The' NRC staff bas completed its review of your July P9 1988 and September 21 1989submittalsinresponsetoGenericLetter(GL)8801. A copy of the stafbs Safety Evaluation with attached copy of the Technical Evaluation Report prepared

- by the staff's contractor, Viking Systems International, is enclosed.

t Based on the Safety Evaluation, the staff finds your responses to GL 88 01 is acceptable with some exceptions.

You are requested to review these exceptions and notify the staff of actions taken to address them. We note that you have submitted a Technical Specification change request in support of the positions in GL 88 01. Our review of those proposed changes will be l

conducted separately, t

for Safety Evaluation deficiencies related to welds, categorization of welds, and qualification of personnel, these deficiencies shall be corrected in the corrosion cracking (you previously submitted integrated intergranular stress ISI program. Since IGSCC) inspection plans, our safety evaluation precludes the necessity for you to submit IGSCC. inspection plans for each future outage.

However, if-flaws are found'that do not meet the criteria of Section XI of the ASME Code for continued operation without evaluation, NRC approval of flaw evaluations or repairs in accordance with IWD 3640 and IWB'T130 is required before resumption of operation.

Note that weld overlay repair is considered as a non. code repair, which requires NRC approval.

<J8 Sincerely, won.

88 Original signed by John N. Hannon for/

i

$8 John B. Hickman, Project Manager Project Directorate - III.3 M

Division of Reactor Projects. III, g8 IV, Y and Special Projects

.M Office of Nuclear Reactor Regulation T

Enclosure:

gg Safety Evaluation with attached osoA Technical Evaluation Report 3

cc w/ enclosure <

q g'

See next page h

0FC

LA:PD3/3:DRSP
P P :D:PD;

.DRSP :

1 \\:

..:....,..;.......:...............:............J.:...........

NAME :PKyJJ ICKMAN: jar :JHANNON

...... :.. J.'.J3E R DATE :8/%/90

8/4 /90
8 /14 # / 9 0 OFFJCIAL RECORD COPY q

. Document Name: 69130 GL88 01

?!

j s.

~

L 4

Mr. Frank A. Spangenberg Clinton Power Station Illinois Power Company Unit 1 l

cc: Mr. J. S. Perry Illinois Department Vice President of Nuclear Safety l

Clinton Power Station Office of Nuclear Facility Safety i

P. O. Box 678 1035 Outer Park Drive 1

Clinton, Illinois, 61727 Springfield, Illinois 62704 j

Mr. J; A'. Miller Mr. Donald Schopfer Manager Nuclear Station Project Manager Engineering Dept.

Sargent & Lundy Engineers Clinton Power Station 55 East Monroe Street J

P. O. Box 678 Chicago, Illinois 60603 Clinton, Illinois 61727 Sheldon Zabel, Esquire i

Schiff, Hardin & Waite 7200 Sears Tower 233 Wacker Drive Chicago, Illinois 60606 Resident Inspector U. S. Nuclear Regulatory Comission RRf3, Box 229 A Clinton Illinois 61727 J

1 Mr. L.'Larson Project Manager General Electric Company 175 Curtner Avenue N/C 395 i

San Jose, California 95125 Regional Administrator, Region III i

799 Roosevelt Road Bldg. #4 Glen Ellya, 1111nols60137

. Chairman of DeWitt County c/o County Clerk's Office DeWitt County Courthouse Clinton, Illinois 61727 i

Robert Neumann Office of Public Counsel State of Illinois Center 100 W. Randol Suite 11-300 ph l

Chicago, Illinois 60601 J

7 4

9 m -

-