ML20059C074

From kanterella
Jump to navigation Jump to search
EN-90-082:on 900830,notice of Proposed Imposition of Civil Penalty in Amount of $62,500 Will Be Issued to Licensee Based on Technicians Receiving Unplanned Radiation Exposures for Activated Traversing Incore Probe
ML20059C074
Person / Time
Site: Brunswick  
Issue date: 08/27/1990
From: Lieberman J, Luehman J
NRC OFFICE OF ENFORCEMENT (OE)
To:
References
EA-90-130, EN-90-082, EN-90-82, NUDOCS 9008310036
Download: ML20059C074 (1)


Text

- -.-

i=

)

August 27, 1990 EN 90-082 0FFICE OF ENFORCEMENT

-NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION Licensee: Carolina Power & Light Company (EA90-130)

-(Brunswick)

Docket Nos.

50-325 and 50-324 l

Subject:

PROPOSED IMPO3ITION OF CIVIL PENALTY

$62,500 This is to inform the Cosmiission that a Notice of Violation and Proposed l

Imposition of Civil Penalty in the amount of $62,500 will be issued on or about August 30, 1990 to the Carolina Power & Light Company (Brunswick). This action t

is based on an event that occurred on-July 5,1990. During work on the Unit I traversing incore probe (TIP) plant technicians received unplanned radiation R

exposures from an activated TIP having a. radiation dose. rate of approximately 1000 rem per hour on contact. While no regulatory radiation exposure limits were violated, it was determined that a substantial potential for overexposures existed. The base civil penalty of $50,000 was-escalated 25 percent after partially off-setting the escalation for prior notice of similar events by mitigation-for identification and reporting as well as corrective actions.

It should be noteo' that the licensee has not been specifically informed of the enforcement action. The schedule of issuance and notification is:

Mailing of Notice August 30, 1990 Telephone Notification of Licensee

. August 30, 1990 The State of North Carolina will be notified.

The licensee has thirty days from the date of the' Notice in which to respond.

Following NRC evaluation of the response, the civil penalty may be remitted, mitigated, or imposed by Order.

~

Contact:

J. Luehman, OE, 23280 J. Lieberman, OE, 20741 Distribution OWFN_ M OWFN 3:10 MNBB 3l10 PHIL T IO Chairman Carr EDO OC IRM' Comm. Rogers DEDR AE0D Comm. Curtiss DEDS Op:Ctr Comm. Remick OE NMSS SECY NRR OCA 01 GPA OGC SP Regional Offices MAIL RI 3'/D RIV 3l/O ADM: Doc. Mgt. Br.

RII 5:to RV 3//o PDR ACRS RIII Ml/o RES DIG PRELIMINARY INFORMATION - NOT FOR PUBLIC DISCLOSURE UNTIL PUBLICLY ANNOUNCED

-cos27 083 PDC qp Y

$Ao-ggsg