October 20, 1993 Docket Hos. 50-498 and 50-499 MEMORANDUM FOR:

Suzanne C. Black, Project Director Project Directorate IV-2 Division of Reactor Projects III/IV/V FROM:

Lawrence E. Kokajko, Senior Project Manager Project Directorate IV-2 Division of Reactor Projects III/IV/V

SUBJECT:

MEETING WITH HOUSTON LIGHTING & POWER COMPANY (HL&P) TO DISCUSS RESOLUTION OF NRC BULLETIN 88-08 DATE & TIME:

November 8, 1993; 1:30 p.m. - 6:30 p.m.

November 9, 1993; 8:30 a.m. - 6:30 p.m.

November 10, 1993; 8:30 a.m. - 12:00 p.m.

LOCATION:

Westinghouse Energy Corporation Monroeville Energy Center Pittsburgh, PA PURPOSE:

To discuss the licensee's proposed resolution to NRC Bulletin 88-08 in regards to removing instrumentation to monitor thermal stresses in piping connected to the reactor coolant system. A proposed agenda is enclosed.

PARTICIPANTS *:

NRC HL&P Westinahouse L. Kokajko W. Harrison D. Roarty T. Chan M. Kanavos P. Strauch M. Hartzmann S. Patel S. Swamy BNL representative (s)

B. Muhkerji K. Chang BNL subcontractor M. Pacy 9310270053 931020 Original Signed By ADOCK 0500 8

fDR Lawrence E. Kokajko, Senior Project Manager Project Directorate IV-2 Division of Reactor Projects III/IV/V cc:

See next page i

Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitior.ers, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy," 43 Federal Reaister 28058,6/28/78. However, portions of l

f this meeting will discuss proprietary information as defined in 10 CFR 2.790, and will be closed to the public.

g OFFICE PDIVV-2/LA PD,)V-2/PM PDIV-2/SB

[ke ajko;nb SBl T WAME DATE

}0/19 /93 10/ P /93 10/M/93

/

/

'/

/

co" Yes/No h/No Yes/No Yes/No Yes/No i

Document Name b:\\ll-08:tJ3. MIG

l i

Suzanne C. Black October 20, 1993 cc:

Mr. David P. Loveless Jack R. Newman, Esq.

j Senior Resident Inspector Newman & Holtzinger, P.C.

i U.S. Nuclear Regulatory Commission 1615 L Street, N.W.

{

P. O. Box 910 Washington, D.C.

20036 Bay City, Texas 77414 Licensing Representative Mr. J. C. Lanier/M. B. Lee Houston Lighting and Power Company City of Austin Suite 610 l

Electric Utility Department Three Metro Center 1

721 Barton Springs Road Bethesda, Maryland 20814 Austin, Texas 78704 Bureau of Radiation Control Mr. K. J. Fiedler State of Texas Mr. M. T. Hardt 1101 West 49th Street City Public Service Board Austin, Texas 78756 P. O. Box 1771 San Antonio, Texas 78296 Rufus S. Scott Associate General Counsel Mr. G. E. Vaughn Houston Lighting and Power Company Mr. T. M. Puckett P. O. Box 61867 Central Power and Light Company Houston, Texas 77208 P. O. Box 2121 Corpus Christi, Texas 78403 Mr. William T. Cottle Group Vice-President, Nuclear INPO Houston Lighting and Power Company Records Center P. O. Box 1700 700 Galleria Parkway Houston, Texas 77251 Atlanta, Georgia 30339-3064 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Mr. Joseph M. Hendrie 50 Bellport Lane Bellport, New York 11713 Judge, Matagorda County Matagorda County Courthouse 1700 Seventh Street Bay City, Texas 77414 Mr. James J. Sheppard General Manager, Nuclear Licensing Houston Lighting and Power Company P. O. Box 289 Wadsworth, Texas 77483 m

~

ENCLOSURE I PROPOSED AGENDA FOR MEETING BETWEEN HL&P. WESTINGHOUSE. AND USNRC IN REGARD TO BULLETIN 88-08 November 8 - 10, 1993, in Pittsburgh, PA Monday. November 8. 1993

  • Start of Meeting and Introductions (1:30 pm)

- USNRC & contractual support personnel (BNL and subcontractor)

- HL&P

- Westinghouse

- Others (e.g., EPRI)

M

  • Meeting Objectives (apx 1:45 pm)

= Discussion of Phenomena (apx. 2:00 pm) t

- TASCS testing program

- MHI testing program

- Videotape

. TASCS Evaluation Methodology (apx. 3:00 pm)

- Note: Primary focus on South Texas Project, not generic

- Height of stratified flows

- Heat transfer of stratified flows

- Thermal cycling zone

- Turbulent penetration length

- Heat transfer of uniform flows

  • Discussion and Question / Answer Session (apx. 4:30 pm)
  • Adjourn (apx. 6:30 pm) j i

. Tuesday. November 9. 1993 *

  • Reconvene Meeting (8:30 am)

- Continuation of discussion from previous day, if necessary

. Review of HL&P Monitoring and Analyses (apx. 9:00 am)

- Monitoring program

- Residual heat removal analysis

- Charging and alternate charging analysis

- Auxiliary spray line analysis

  • Lunch (apx. 11:30 am - 12:30 pm)
  • Discussion and Question / Answer Session (apx. 12:30 pm)

- Continuation of morning session, if necessary

- Time available for independent study, if necessary

. Adjourn (apx. 6:30 pm)

Wednesday. November 10. 1993 *

  • Reconvene Meeting (8:30)

- Continuation of discussion from previous day, if necessary Tour of Westinghouse Test Facilities (apx. 9:00 am)

. Discussion and Question / Answer Session (apx. 10:30 am)

  • Summary and Conclusion (apx. 11:30) j

- Follow-up actions and documentation

- Final remarks t

  • Adjourn Meeting (12:00, Noon)

DISTRIBUTION - Routine Meetina Notice Docket File NRC PDR Local PDR PD IV-2 Reading T. Hurley/F. Miraglia J. Partlow J. Roe E. Adensam S. Black L. Kokajko E. Peyton A. Chaffee, OEAB OGC E. Jordan E. Rossi Receptionist (0WFN)

NRC Participants ACRS (10)

OPA NRR Mailroom, PMAS,12/G/18 P. O' Dell, PMAS G. Zech, RPEB J. Gilliland, Region IV l