Notice of Violation from Insp on 931115-1203.Violation Noted:Ist Procedure CPS 9069.01 Contained Inadequate Acceptance Criteria to Verify That Following Check Valves Were Exercised Quarterly to Full Open Position
ML20059A288
Person / Time
Site: Clinton 
Issue date: 12/23/1993
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20059A286 List:
References
50-461-93-24, NUDOCS 9312300094
Download: ML20059A288 (1)


Text

.

I NOTICE OF VIOLATION i

Illinois Power Company Docket No. 50-461 Clinton Power Station License No. NPF-62 As a result of the inspection conducted on November 15 through December 3, 1993, and in accordance with the " General Statement of Policy. and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C, (Enforcement Policy) the following violation was identified:

Technical Specification 4.0.5.a states "... inservice testing of ASME Code Class 1, 2, and 3 pumps and valves shall be performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code..." ASME Section XI, IWV-3522, " Exercising Procedure," states, in part " check valves shall: be -

exercised to the position required to fulfill their function..."

Contrary to the above, inservice test procedure CPS No. 9069.01,= Shutdown Service Water Operability Test, dated September 20, 1993, contained inadequate acceptance criteria to verify that the following check valves were exercised quarterly to their full open position:

a.

Shutdown service water pump discharge check valves ISX001A and ISX001B.

required 11,655 and 11,632 gpm flow, respectively to verify full open, whereas the test acceptance criteria was 8937-9070 gpm.

b.

Shutdown service water pump discharge check valves ISX001C required 839 gpm flow to verify full open, whereas the test acceptance criterion was 743-757 gpm.

This is a Severity Level IV violation (Supplement I.D.3).

j

^

The inspection showed that steps had been taken to correct the identified violation and to prevent recurrence. Consequently, no reply to the violation is required and we have no further questions regarding this matter, i

Dated at Lisle, Illinois this 23rd day of December 1993 9312300094 931223 i