QUALITY ASSURANCE PLAN Docket 50-602 Nuclear Engineering Teaching Laboratory Balcones Research Center The University of Texas at Austin 9008200039 900815 PDR ADOCK 07100535 C

PDC

QUALITY ASSURANCE l'ROGRAM Objectives of quality assurance (QA) may be divided into two major goals.

First is the goal of safe operation of equipment and activities to prevent or mitigate an impact on public health and safety.

Second is

~

the reliable operation of equipment and activities associated with education and research functions of the University.

The risk or potential release of radioactive materials is the primary impact on public health and safety, and may be divided into direct risks and indirect risks.

Direct risks are activities such as waste disposal, fuel trar: sport and decommissioning that introduce radioactive materials into the public don.ain.

Indirect risks are accident conditions created by normal or abnormal operating conditions that generate the potential or actual release of radioactive materials from the controlled areas of a facility.

1, htroduction Characteristics of uranium loaded zirconium hydride fuel used in the TRIGA reactor provide substantial benefits to safe reactor operation.

Many accident situations are simulated by normal operation of the fuel in either pulse mode or steady state mode.

Other features such as fission product retention, stainless steel cladding design, facility engineered features, and periodic schedule of operation combine with routine operation procedures to decrease the consequences. of failure of any reactor components.

The limited scope of application of formal quality assurance criteria is due to the f act that most parts and procedures associated with operation of the TRIGA type reactor are not relevant to public health and safety.

2 1

a

1 p.

lb

l

,1 -

4 i

^k?' ;

t Ml:- >

l JP,

.M U

[p. oi; Table 1 di Q-List for IMW UT TRIGA I

y.

,q-nOff QC/Qh L+

Structures, systens or components safety

  • Specs Fuel' Element Cladding structure 1

manuf.-

j

_ -4.

Shipping package 1

nanuf.

l

$$'\\

Reactor Core j

Structural components 2

nanut.

'y I

Tank structure 2

design

(

Shield structure 2

constr.

Experiment Equipment (core reflector)

Beam tube components 2

design Rotary rack system 2

design f

Experiment Equipment - (core grid)

Pneumatic tube components 2

design i

Installed core system 2

design r

Protective Systems f

= Instrunentation system 2

manuf.

)

Control system 2

-manuf.,

l Safety. system-2

manuf, i

Auxiliary Systems

= Pool coolant system 2

des.ign Water purification system 2

design s

'[

Room confinement components 2

const.

7 Area ventilation components 2

const.

Area radiation monitor system 2

manuf.

Air radiation monitor system 2

manuf.

1-All sections of quality' assurance. program shall be' considered f

. applicable.

2--

Specific sections of quality assurance program.should be applied as reqvired to assure reliable performance.

i

(

m l

"d '

t i

'L i :-.

?

i l?

P

!t 6

t 8

Safety-related identifications for quality assurance are determined from safety analyses.

Although several systens such as the reactor safety and protection system, engineered safety features and radiation monitoring systems are important to safety, only one reactor component is identified as safety-related.

The quality assurance program is not applied to routine reactor operations and surveillance activities but shall be implemented for non routine activities determined to be safety-related in nature or af fecting safety-related components.

Activities shall include design, construction, testing, modification an1 maintenance of safety-related items.

Other components related to safety lindte, lindting conditions for operation and design features, as identified in technical specifications, will apply only those elements of quality assurance necessary to establish reliable perf ormance of the intended structure, system or component function.

The following table lists the components subject to quality assurance program or selected sections of the program.

Two additional conditions remain, however, that are important to the application of at least portions of the quality assurance program.

One is the safety to operation personnel and experimenters and the other is continuity of the operations programs.

Each of these conditions must be examined objectively relative to operation procedures and program expectations.

In general, the application of good industry quality assurance practices is sufficient to meet operational program goals.

The quality assurance program shall be commensurate with the TRIGA type reactor, The University of Texas administrative programs and the goals of cpality assurance.

This document provides requirements for establishing, managing, conducting and evaluating the QA Prograu.

The QA Program applied to items or activities determined to be safety-related follows the guidelines of Nuclear Regulatory Guide 2.5 (77/05)

(9,10).

1.1 Purnose.

Quality assurance of certain activities associated with the University of Texas TRIGA reactor facility is important for the safe and efficient completion of tasks that are identified as safety-related.

This document outlines the general elements of quality assurance applied' to safety-related structures, systems or components, and activities.

Requirements are documented for establishing, managing, conducting, and evaluating the QA Program.

Although aspects of the QA Program may be routinely applied to many facility activities, the formal implementation of the program is limited to specific items or activities related to public health and safety.

Table 1 lists the quality level and description of key systems and components.

1.2 Responsibility.

The University of Texas at Austin as owner and operator of the TRIGA reactor f acility shall be responsible for a quality assurance prograu.

The owner-operator shall establish and implement a program consistent with the goals of quality assurance for safety-related activities, structures, systems and components.

Identification of safety-related items shall be the responsibility of the owner-operator and will includ_ a description of the item and the applicable elements of the quality assurance program.

Special quality 4

-j

\\

I 1

provisions, delegated functions of the program, and unresolved quality assurance problems shall also be identified by the owner-operator.

The facility supervisor shall have the ultimate responsibility foi coth the specifications of quality related requirement s and the functions of quality related activities.

Table 2 lists the responsibilities and key personne1' participating in the University TRIGA QA Program.

J Table 2 RESPONSIBILITIES AND KEY PERSONNEL Rampensibilitian gay tiniversity Parannnel

1. Establish program Director or Supervisor Implement program of TRIGA facility Identify Safety-related items
2. Unresolved issues President or Executive Vice President and Provost
3. Delegated functions Faculty and staff
4. Specialized functions Specified personnel l

=>

1.3 organization. The organization applied to quality assurance activities shall be part of the normal university administrative structure.

The f acility Supervisor - ehall develop and

~

implement the quality assurance program and identify safety related items.

Unresolved issues of quality assurance shall be reported to the Director of the f acility and the appropriate administrative vice president of the university.

Execution of specific elements of the program may be delegated to persons in the University organization or other organizations as appropriate.

University persons shall include committees, faculty, researchers or staff as required for specific program applications.

Non-univer ity organizations or persons may supplement University personnel when specialized qualifications are i

necessary for specific quality ' assurance tasks.

The University organization applied to reactor safety and quality assurance is. the academic administration represented by Figure 3.

1.4 DAc"mentatinn.

All activities affecting safety-related items sublect to the quality assurance program shall be identified and documented formally.

The format of. Table 3 shall be used to identify applicable elements of the Quality Assurance Program and identify documents, procedures, reviews, inspections, tests, or other quality assurance features that are to be applied to a safety-related activity.

The checklist or approval shall be incorporated in the table format for the acceptance of each specified quality assurance element by the f acility supervisor.

5

I i

Line Organization 6

QUALITY ASSURANCE ORGANIEATION r

k Office of the President The University of Texas at Austin i

ExecutAve Vice President and Provost i

Director of i

Nuclear Engineering Teachincy T.aboratory Assistant Director neactor supervisor r

h t

r ACADEMIC ORGANIZATION Figure 1 6

.l y- ;.

1-t l

1 Table 3 FORMAT FOR SAFETY RELATED QA CHECKS 7

t

!i Each safety-related activity structure, system, or comp $nent will be' given a. letter symbol, such as A, B,

C, and be appended with the

{

following designations (for example,' A1.0):

i 1.0 : Title l

Identification and description of safety-related item i

1.1 Participation - supplemental organization and functions

[*

1.2 Documents - applicable procedures or special. measures 2.1 Design Control 2.1.1. Codes, standards and regulations 2.1.2 Method of verification i

2.1.3 Modifications proposed i

2.2 Procurenent Control I

2.2.1 Codes, standards and regulations 2.2.2 Quality assurance specifications l

2.2.3. Proposed changes enacted j

2.2.4 Procurerent-conformance method j

2.3' Document Control t

2.4 Material Control l

.2.4.1-Special procedures required i

2.4.2~ Equipment required

'[

2.4.3. Personnel qualifications 2.5 Process Control

-i 2.5.1-Special procedures 2.5.2 Special equipment L

2.5.3 Personnel,qualificatione i

3.1 Inspection Program Description

~3.2 Test Program Description 3.3 Measurement Equipment 3.4 Nonconformance item and Disposition

[

3.5-Corrective Acticna Instituted t

4.0 Reco'rds List.

t I

..t

+

2.

Qudity Asaggance centrolm 2.1 Design controin.

Design controls shall consist of design specifications, references to applicable codes, standards and regulations, design verifications and document approval.

Applicable codes, standards, regulations or other quality requirements will be identified and requirements incorporated into the design documents.

Design document approvals shall be part of the design document.

Design approval will be by a person, other than the design originator, that is knowledgeable of the design criteria and is informed of the quality requirements.

Modifications of safety-related documents shall be subject to the same provisions as the original document.

Approval of the design modification will be included with the design document an ~ the modification identified.

Verification of design adequacy shall be provided by either design reviews, alternate calculation, test program or other method, determined to be appropriate.

Verifications of the design shall check characteristics such as compatibility of materials; suitability of application of inspection, maintenance and repairs proper interfacing of sub-systems, and proper acceptance criteria.

Method of verification will be identified and documented by approval of the design document.

2.2 Erneurement centrols.

Procurement controls shall consist of procurecent specifications, references to applicable codes, standards and regulations, procurement acs'otance and document approval.

Applicable code, standards, regulations or other quality requirements will be identificd and references incorporated into the procurement documents.

Procurement document approvals shall be part of the procurement documen'..

Procurement approval will be by a person, other than procuremvat orJginator, that is knowledgeable of the procurement specifications and is informed of the quality requirements.

Changes to safety-related procurement documents shall be subject to the same provisions as the original document.

Approval of procurement changes will be included with the procurement document and the change identified.

Acceptance of procured items or services shall consist of evidence provided by the contractor, evaluation of the procurement source, inspection at the source or inspection upon receipt.

Acceptance of the procurement should require measures such as quality assurance by contractor, inspection and test functions, or controls on naterials processes and nonconformances.

The methods of acceptance will be identified and documented by approval of the procurement document.

2.3 Dncument co ur.ol.

Document control consists of monitoring the development, revision, release and ut.e of documents, drawings or specifications affecting safety-related activities.

Document contrcl shall include assurance that safety reinted documents are identified as such, and are completmt and traintained properly.

The 8

laboratory Supervisor shall provide control of safety related documents that are specified according to the format of Table 2.

2.4 tialarial control.

Procedures shall be written to establish material control when special measures are necessary to assure material quality of safety-related items.

Controls shall be applied to activities such as identification, handling, storage, shipping, cleaning and preservation.

Procedures shall specify equipment and personnel required to accomplish the specified material control.

Applicable codes, standards, specifications and personnel qualifications shall be oocumented.

2.5 Erncass control.

Procedures shall be written to establish process control when special neasures are necessary to assure procesa quality of safety-related items.

Controls shall be applied to activities such as crimping, soldering, welding, painting, cleaning and heat treating.

Procedures shall specify qualifications of equipment and personnel required to perform the appropriate process control.

Applicable codes, standards, specifications and personnel qualifications shall be documented.

3.

Ingection and corrective Actions 3.1 Ingentien program.

An inspection program shall be established for safety related items or activities.

The inspection program shall apply to construction, procurements, experiment equipment fabrication, and modifications that effect safety-related structures, systems, or components.

Persons delegated to perform inspections shall not be the same person involved in the safety-related activity but may be from the same organization.

The inspection program will consist of written procedures that will include, as appropriate, procedures specifying characteristics to be inspected, acceptance criteria and inspection hold points.

Procedures should provide for identification of inspected and tested items.

Provisions shall be made to clearly identify non conforming items from conforming items.

In situations that inspections are not advantageous a description shall be provided f or monitoring actions.

Procedures shall be written for in service inspections of safety-related structures, systems or components.

3.2 Inst Program.

A test program shall be established - for safety-related items or activities.

The test program shall apply to prototype qualifications, installation proofs and functional tests.

Testing shall be performed in accordance with acceptance criteria derived from design or procurement documents.

The test program will consist of written procedures that will include, as appropriate, procedures that specify acceptance criteria, monitoring requirements, equipment required, personnel qualificatic.s, 9

l

environmental conditions, data acquisition, and documentation of results.

3.3 Measuring and 're s t Equipment.

Measurement tools, gages, instruments, and other measuring or test devices that measure critical paraneters of safety-related items shall be identified.

Provisions for identified measuring and test devices shall include availability, adjustment, calibration and accuracy as required for each application.

Test equipment will be identified.

3.4 Non-cenforming Material _and Parts.

Non-conforming materials and parts associated with safety-related structures, systems or components shall be identified.

The disposition such as acceptance, repair, rework or rejection of parts from safety-related functions will be determined by the person responsible for document control. Repair or reworked parts will be removed or labeled until accepted.

Rejected parts will be removed and labeled.

The disposition of non conforming i

materials will be documented.

3.5 CarIastive Action.

Documentation of specified quality control or assurance documents shall provide evidence of quality of safety-related items.

Significant deviations from acceptable quality, repeated quality problems or unresolved quality issues shall be noted and reported in writing to administrative management personnel.

It should be recognized that a determination of a quality problem may be subjective and should include evaluation of the documented quality requirements relative to the impact on the safety-related nature of the i

item.

3.6 Experimental Equipment.

Design, construction, modification, inspection, testing and maintenance of experimental equipment shall be subject to this quality assurance program to the extent that these activities are safety-related.

3.7 Replacements. Modi f i c a t_i_pn s. or changgL.

Insofar as possible, the replacement, modification, or change to structures, systems or components with a safety-related function shall be documented as meeting the requirements of the original structure, syv em or component.

Evaluation should establish a performance and reliability equivalent or exceeding the original.

4.

Records and Audits 4.1 cuality Assurance Re c Q.Ida.

Records that document quality-of safety-related items or activities are identified according to Table 3.

The records identified consist of inspection and test results, quality assurance reviews, quality assurance procedures and engineering analysis in support of design modifications or changes.

The records shall be retained with as-built drawings, manuals and other records of important facility and system information.

The retention period is to be the life of the f acility or system for most, if not all, safety-related items.

10

m 44 - 4

.'t i

The retention period is indicative of the.**pectation that items which I

affect safety related to as TRIGA reactor are integrally related to the p

reactor, instrumentation and f acility design and should persist for the system or facility life.

i 4.2 Audi ta.

An audit shall be conducted to examine the~

[

records and function of the quality' assurance program.

Audits will occur within two years of the QA Program activities by designated persons that were not directly responsible for the oudited functions.

Written procedures, Table 4, for the audit will be considered part of the Quality Assurance Program.

A' report of'the audit results, actions e

to resolve deficiencies and evaluation of the program will be made to a f acility operations committee and university administrative management, and maintained with other Quality Assurance Program documents.

i Table 4 QUALITY ASSURANCE PROGRAM E

AUDIT PROCEDURES

-1.

Designate a person or persons responsible to perform the program audit.

l 2.

Determine the date of the previous audit, i

3.

Review the Quality Assurance. Program document.

4.

Examine the list of safety-related items.

5.

Note additions to the safety-related items.

6.

Identify records applicable to additional itens.

7.

Determine the location of all indicated records.

8.

Review records for abnormalities and completentss.

,r 9.

Prepare statement that evaluates functions of Ouality Assurance Program.

10.

Report findings-of audit and program functions to i

operations committee and management.-

t Y

s Y

1 11 l

l