n
,)
-
DEC 011993
Docket Nos.
50-369 and 50-370
Duke Power Company
ATTN: Mr. T. C. McMeekin
Vice President
McGuire Site
-
12700 Hagers Ferry Road (MG01A)
Huntersville, NC 28078-8985
Gentlemen:
SUBJECT: NRC INSPECTION REPORT NOS. 50-369/93-18 AND 50-370/93-18
Thank you for your response of November 15, 1993, to our Notice of Violation
issued on October 20, 1993, concerning activities conducted at your McGuire
facility. We have evaluated your response and found that it meets the
,
requirements of 10 CFR 2.201. We will examine the implementation of your
,
corrective actions during future inspections.
We appreciate your cooperation in this matter.
Sincerely,
ORIaluAt S:g,(o y
ALAN R. HERDT
Alan R. Herdt, Chief
Reactor Projects Branch 3
Division of Reactor Projects
cc:
R. O. Sharpe
.
'
Compliance
Duke Power Company
12700 Hagers Ferry Road
Huntersville, NC 28078-8985
G. A. Copp
Licensing - EC050
'
Duke Power Company
P. O. Box 1007
Charlotte, NC 28242
A. V. Carr, Esq.
,
Duke Power Company
422 South Church Street
Charlotte, NC 28242-0001
cc:
Continued see page 2
l
.
1 0
230037
9312270218 931201
ADOCK 05000369
8
""
IEO(
-
y
_
,
- :.
0
-
>
DkC 011993
Duke Power Company
2
,
cc:
Continued
J. Michael McGarry, III, Esq.
i
Winston and Strawn
'
1400 L Street, NW
Washington, D. C.
20005
Dayne H. Brown, Director
t
Division of Radiation Protection
N. C. Department of Environment,
i
Health & Natural Resources
P. O. Box 27687
i
s.
Raleigh, NC 27611-7687
County Manager of Mecklenburg County
720 East Fourth Street
Charlotte, NC 28202
i
T. Richard Puryear
,
Nuclear Technical Services Manager
,
Carolinas District
!
Westinghouse Electric Corporation
2709 Water Ridge Parkway, Ste. 430
Charlotte, NC 28217
'
Dr. John M. Barry, Director
',
Mecklenburg County Department
of Environmental Protection
700 North Tryon Street
,
Charlotte, NC 28203
,
Karen E.'Long
d
Assistant Attorney General
N. C. Department of Justice
P. O. Box 629
l
Raleigh, NC 27602
bec:
V. Nerses, NRR
R. Watkins, RII
{
M. S. Lesser, RII-
'
A. R. Herdt, Rll
Document Control Desk
NRC Resident Inspector
U.S. Nuclear Regulatory Commission
12700 Hagers Ferry Road
Huntersville, NC 28078-8985
RII
RII
fatkins
Me er
1/ /93
$l/93
)
u