Text
,
0 UNIDENTIFIED LEAKAGE 1.36 UNIDENTIFIED LEAKAGE shall be all leakage which is not IDENTIFIED LEAKAGE or CONTROLLED LEAKAGE.
UNRESTRICTED AREA 1.37 An UNRESTRICTED AREA shall be any area, at or beyond the site boundary, to which access is not controlled by the licensee for purposes of protection of individuals from exposure to radiation and radioactive materials or any area within the site boundary used for residential quarters or industrial, commercial, institutional, and/or recreational purposes.
VENTILATION EXHAUST TREATMENT SYSTEM 1,38 A VENTILATION EXHAUST TREATMENT SYSTEM is any system designed and installed to reduce gaseous radiciodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters for the purpose of removing iodines or particulates from the gaseous exhaust stream prior to the release to the environment (such a system is not considered to have any effect on noble gas '
effluents).
Engineered Safety Feature (ESF) atmospheric cleanup systems are not considered to be VENTILATION EXHAUST TREATMENT SYSTEM components.
VENTING 1.39 VENTING is the controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration or other operating condition, in such a manner that replacement air or gas is not provided or required during VENTING. Vent, used in system names, does not imply a VENTING process.
I l
9312230035 931215' PDR ADOCK 05000327 P
PDR.
SEQUOYAH - UNIT 1 1-7 Amendment No. 12, 71, 155, 174
p
. DEFINITIONS
.i SOLIDIFICATION 1.32 - Deleted.
SOURCE CHECK 1.33 Deleted.
STAGGERED TEST BASIS 1.34 A STAGGERED TEST BASIS shall consist of:
- a. A test schedule for n systems, subsystems, trains or other designated components obtained by dividing the specified test interval into n equal subintervals,
- b. The testing of one system, subsystem, train or other designated component at the beginning of each subinterval.
THERMAL POWER 1.35 THERMAL POWER shall be the total reactor core heat transfer rate to the reactor coolant.
i UNIDENTIFIED LEAKAGE 1.36 UNIDENTIFIED LEAKAGE shall be all leakage which is not IDENTIFIED 1
LEAKAGE or CONTROLLED LEAKAGE.
l UNRESTRICTED AREA 1.37 An UNRESTRICTED AREA shall be any area, at or beyond the site boundary,
]
to which ~ access is not controlled by the licensee for purposes of protection '
of individuals from exposure to radiation and radioactive materials or any j
area within the site boundary'used for residential quarters or industrial,.
commercial, institutional, and/or recreational purposes.
1.
9
-l i
SEQUOYAH - UNIT 2 1-7 Amendment No. 63, 134, 146, 165
. *?