ML20058P024

From kanterella
Jump to navigation Jump to search
Summary of 402nd Meeting of ACRS on 931007-08 Re Proposed Rule & Draft RG to Address Resolution of Generic Issue 23, Reactor Coolant Pump Seal Failure
ML20058P024
Person / Time
Issue date: 10/14/1993
From: Wilkins J
Advisory Committee on Reactor Safeguards
To: Taylor J
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
References
REF-GTECI-023, REF-GTECI-NI, TASK-023, TASK-23, TASK-OR ACRS-R-1538, NUDOCS 9310210318
Download: ML20058P024 (2)


Text

A

,[

'o UNITED STATES

~N NUCLEAR REGULATORY COMMISSION ACRSR-1538

{

,E ADVISORY COMMITTEE ON REACTOR SAFEGUARDS PDR Og g

WASHINGTON, D. C. 20555

,8 October 14, 1993 Mr. James M. Taylor Executive Director for Operations U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Taylor:

SUBJECT:

PROPOSED RULE AND DRAFT REGULATORY GUIDE TO ADDRESS RESOLUTION OF GENERIC ISSUE 23,

" REACTOR COOLANT PUMP SEAL FAILURE" During the 402nd meeting of the Advisory Committee on Reactor Safeguards, October 7-8, 1993, we reviewed a proposed rule and draft regulatory guide deyeloped for resolving Generic Issue 23,

" Reactor Coolant Pump Seal Failure."

Our Subcommittee on Decay Heat Removal Systems met on October 5, 1993, to review this matter.

During this review, we had discussions with representatives of the NRC staff, Northeast Utilities, and NUMARC.

We also had the benefit of the referenced documents.

We do not believe that the proposed rule and draft regulatory guide should be issued for public comment in their present form.

There are several aspects of the rulemaking package that need further attention.

For example, the proposed rule is too deterministic and does not permit consideration of the wide variation in risk from pump seal LOCA among the different plants.

We believe that the proposed rule should be revised to permit the use of a risk-based approach.

Furthermore, the provision in the regulatory guide that either seal cooling be restored within 10 minutes or a seal leakage rate of 480 GPM per reactor coolant pump be assumed appears to be overly conservative.

This provision will have a serious impact on the coping analyses already performed to meet the strictures of the Station Blackout Rule.

There is clearly a need for further dialogue among the NRC staff, the nuclear industry, and the ACRS.

We wish to be kept informed regarding the resolution of this matter.

Sincerely,

_ wJJ}

o J.

Ernest Wilkin, Jr.

Chairman b- 0 200052

\\0 9310210318 931014 PDR ACRS

((

R-1538 PDR

s

" 1f Mr. James M. Taylor 2

october 14, 1993

References:

Memorandum dated August 3, 1993, from C.

J. Heltemes, Jr., Office of Nuclear Regulatory Research, to J.

Ernest Wilkins, Jr.,

ACRS Chairman,

Subject:

Proposed Rule for GI-23, " Reactor Coolant Pump Seal Failure," with following enclosures (1)

Draft NUREG-1483, " Regulatory Analysis Supporting Proposed Rule on Reactor Coolant Pump Seals"

,(2)

Proposed Federal Reaister notice (3)

Draft Regulatory Guide, DG-1008, Revision 1,

" Reactor Coolant Pump Seals."

t 9

i i

r a.