Monthly Operating Rept for June 1982
ML20058J869
Person / Time
Site: San Onofre 
Issue date: 07/06/1982
From: Raidy T
SOUTHERN CALIFORNIA EDISON CO.
To:
Shared Package
ML20058J866 List:
References
NUDOCS 8208120152
Download: ML20058J869 (5)


Text

{{#Wiki_filter:. AC40 RA 4 NRC MONTHLY OPERATING REPORT DOCKET NO 50-206 DATE 6 July l982 COMPLETED BY ~ Ri-__ TELEPHONE - 00 Ext. 702 OPERATING STATUS

1. Unit Name:

San Onofre Nuclear Generatino Station, Unit 1

2. deporting Period:

1 June 1982 through 30 June 19R2

3. Licensed Thermal Power (Mhil:

1347 456

4. Nameplate Rating (Gross MWe,.

436

5. Design Electrical Rating (Net MWe);

456

6. Masimum Dependable Capacity (Gross Mwe):

436

7. Maximum Dependable Capacity (Net Mhe):
8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Rea>ons:

N/A

9. Power Level To Which Restricted.lf Any (Net MWel:

N/A N/A

10. Remns For Restrictions. lf Any:

This Month Yr..to Date CumuLitise 720 4343 131,863

11. Hours in Reporting Period 0

1374.2 88,430

12. Number Of Hours Rescior was Critical
13. Reactor Resene Shutdown Hours 0

0 0

14. Hours Generator On.Line 0

1372.3 84.818.15 0 0 0

15. Unit Resene Shutdown flours 0

1.585.041.8 108.263.946.8 i

16. Gross Thermal Energy Generated (MWH) 0 540.000 37.203.434 l

17 Grow Electrical Energy Generated IMWH, 0 510,223 34,933,054 l

18. Net Electrical Ener'g5 Generated (MWH) 0%

31.64 % 64.031

19. Unit Senice Factor 0%

31.64%

64. 03 x, 20 Unit Asailability Factor 0%

26.94% 60.76% 21 Umt Capacits Factor IUsing MDC NetI 0% 26.94% 60.76% 2.'. Uma Capacity Factor (Using DER Net) 0% 0% 21.93%

23. Uma Forced Outage Rate
24. Shutdowns Scheduled Oser Nest 6 Month IT.s pe.Date.and Duration of Each p:

The current outage began 2/27/82 and is scheduled for completion by 28 Nov.1982 l

25. If Shur Down 4: End Of Report Period. Estimated Date of Startup:

November 28. 1982 2ti. Units in Test StaruuPrior to Commercial Operations-Forecast Achiesed l INill \\ L CRi flCA LIT Y INITI\\L ELECTRICITY COMMERCI AL OPER ATION A paso (s) ses se a w s /,a 8208120152 820706 ,'--- PDR ADOCK 05000206 R PDR

e e UNIT SilUTDOWNS AND POWER REDUCTIONS DOCKETNO. 50-206 UNIT N AME RnNC9 1 DATE 6 Julv 1982 COMPLETED BY T. Raidy REPORT MONTil June TELEPHONE 714-492-7700 t.X T.. /U2 "s =, ee 3 .aa O h 2e s yE4 1.w.ensee g r, g4 Cauw A correceive ,b' Dale 5E 4 2iE 1: vent u7 j'? 9 Aoion to 5E E j5g Report 8' 'E U Psevent Rei;urrente 6 I' 78 2/27/82 S 720 B 1 N/A 22 N/A Extended outage to accomplish seismic backfit and miscellaneous maintenance items. 1 2 1 4 I l'..r.cd R eas..n Metinal: 1.sluin F. Instinctions S Sin d nled A.I quipment !.nlure ( Esplain) l Manual tiu Prepa:Ati.en of Data II.Manitenance or Test 2 Manual Scrain. Ent ) Shesis sin Iiseince ( u Reincling 3 Autoinatic St.un. I veni Rep os el i RIl'ile iNitRI G-In Rcrul d'H) Rest r ation 4 Other (Explanil Ol til l i Opce.it..i Is.sining & lic ense 1.umination 1 - Adniinnisasi.c 5 (, Opci.iinen.il i uso (l'spl.no) l'stuballl S.nne S.unce 11 I)llics ll %pl.asill e s.o t.1 s,....n.

AVER AGE DAILY UNIT POWER LEVEL DOCKET NO. 56-206 UNIT SONGS-1 DATE 6 July 1982 T. Raidy COMPLETED BY TELEPHONE 714-492-7700 Ext. 702 June MONTH DAY AVERAGE ILY P ER LEVEL DAY AVER AGE D AILY POhER LEVEL iMWe-Net i 1 0 0 17 2 0 i8 0 0 0 3 i, 0 0 4 20 5 0 21 0 6 0 0 0 0 7 ,3 0 0 8 ,4 0 0 9 's 0 0 Io ,6 0 o Ii e 3 0 0 13 ,9 0 o 14 39 is 0 N/A ti o i, ( I ....i,3.......,,, ' em m m-e so ,,_m

REFUELING INFORMATION DGCKET N0'.' 50-206 UNIT SONGS-1 DATE 6 July 1982 COMPLETED BY T. Raidy TELEPHONE 714-492-7700 Ext. 702 Date/ Time Event June 1, 0001 Unit is in cold shutdown status for upgrading seismic restraints and to perform miscellaneous maintenance work. June 9, 1205 North mixed-bed demineralizer placed in service; south demineralizer valved out because of high chlorides and suspended solids in the reactor coolant. The unsaturated north demineralizer reduced the reactor coolant boron concentration from 2358 ppm to 2147 ppm which is a violation of Tech. Spec. 3.6.lB(3). The Resident NRC Inspector was notified of this event at 1220 on June 10, 1982 after analysis of the Reactor Coolant revealed the reduction in boron concentration. SIR-82-24 and LER 82-016 were generated to document this event. June 14, 0210 South waste gas decay tank found at 0 pressure. The pressure had been approximately 25 psi. Isolated the tank and investigating the reason for the pressure drop. 6.22 x 10-{ysis of the tggk contents indicates that Ana curies of KR was released. The NRC was notified of this event and a subsequent LER 82-017 was generated to document this event. June 18, 2130 No. 2 Diesel Generator was returned to service after the pistons were modified and miscellaneous maintenance work was performed. The temporary 480 volt Diesel Generators are no longer required to be operable. June 30, 2400 The unit remains in cold shutdown status for seismic restraints modifications and miscellaneous maintenance.

~ :- REFUELING INFORMATION DOCKET NO. 50-206 UNIT SONGS 1 DATE 6 July 1982 ' COMPLETED BY T. Raidy 714/492-7700 Ext. 702 TELEPHONE 1. Scheduled date for next refueling shutdown. December 1983 2. Scheduled date for restart following refueling. March 1984 3. Will refueling or resumption of operation thereafter require a Technical Specification change or other license amendment? Not yet determined What will these be? Not yet determined 4. Scheduled date for submitting proposed licensing action and supporting information. Not yet determined 5. Important licensing considerations associated with refueling, e.g. new or different fuel design or supplier, unreviewed design or performance analysis methods, significant changes in fuel design, new operating procedures. Not yet determined 6. The number of fuel assemblies. a) In the core 157 b) In the spent fuel storage pool. 94 7. Licensed spent fuel storage capacity. 216 Intended change in spent fuel storage capacity. None 8. Projected date of last refueling that can be discharged to spent fuel storage pool assuming present capacity. hbrch 1985 ...ot. l in ~..n. m}}