ML20058J105

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Re Licensee Suppl Response to GL 88-01, NRC Position on Intergranular Stress Corrosion (IGSCC) in BWR Austenitic Stainless Steel Piping
ML20058J105
Person / Time
Site: Browns Ferry 
Issue date: 12/03/1993
From: Williams J
Office of Nuclear Reactor Regulation
To: Medford M
Tennessee Valley Authority
Shared Package
ML20058J108 List:
References
GL-88-001, TAC-M85296 NUDOCS 9312130393
Download: ML20058J105 (1)


Text

.,

December 3, 1993 Docket No. 50-296 Dr. Mark 0. Medford, Vice President Technical Support Tennessee Valley Authority 3B Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Dr. Medford:

SUBJECT:

BROWNS FERRY NUCLEAR PLANT UNIT 3 - SAFETY EVALUATION OF SUPPLEMENTAL RESPONSE TO GENERIC LETTER 88-01 (TAC NO. M85296)

By [[letter::05000296/LER-1992-006-03, :on 921203,3D EDG Inadvertently Started & EDG Ground Alarm Received in Control Room.Caused by Short Circuit in Test Leads Connected to EDG Start Circuit.Faulty Test Leads Replaced|letter dated December 28, 1992]], the Tennessee Valley Authority (TVA) submitted its supplemental response to Generic letter 88-01, "NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austenitic Stainless Steel Piping." The NRC staff has reviewed this response, and finds it acceptable, as documented in the enclosed Safety Evaluation.

Please call me at (301) 504-1470 if you have any questions regarding this topic.

Original signed by Joseph F. Williams, Project Manager Project Directorate 11-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page Distribution Docket File NRC & Local PDRs M. Banic BFN Reading S. Varga G. Lainas F. Hebdon B. Clayton J. Williams D. Trimble OGC ACRS (10)

E. Merschoff, RII P. Kellogg, RII J. Crlenjak, RII 0FC PDII-4/LA PDII-4/PMh/

PDII-4/PM PDII-4/Dh/

NAME BC1ayton JWillia[

DTrimble OC'l FHebdo[ Yne DATE 7/ G-/93 lyf 1- /93 n/ 1 /93

/I/ 2,

/93 DOCUMENT NAME:

G:\\BfN/lGSCC3.LTR 08005a NBC RE CENTia CWY 9312130393 931203 i

PDR ADOCK 05000296 I

Th PDR s

.