ML20058H058
| ML20058H058 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 11/01/1990 |
| From: | Oconnor P Office of Nuclear Reactor Regulation |
| To: | Trevors G NEBRASKA PUBLIC POWER DISTRICT |
| References | |
| TASK-***, TASK-OR GL-90-04, GL-90-4, NUDOCS 9011140218 | |
| Download: ML20058H058 (4) | |
Text
-
s A
~
. November 1,1990L Docket No. 50-298 l
Mr. George A. Trevors Senior Staff Advisor - Nuclear Power Group Nebraska Public Power District Post Office Box 499 Columbus, Nebraska' - 68602-0499'
Dear Mr. Trevors:
SUBJECT:
UNIMPLEMENTED GENERIC SAFETY ISSUES AT 000PER hi' CLEAR STATION-On April 25, 1990, the staff issued Generic Letter 90 04 which requested information concerning the implementation status of certain generic safety-
-l issues (GSIs) at your facility.
Based on your. response to this Generic.
Letter, dated June 22, 1990, our own records,-and discussions with your staff, we have updated our-database on GSI implementation status. The results of this effort were presented to the Commission.at a meeting on October 25, 1990.
The enclosure to this letter summarizes the staff's understanding of the current status of.those GSIs which remain unimplemented at' Cooper Nuclear Station. We appreciate the assistance you provided,in responding to Generic Letter 90-04 and we encourage your timely completion of _those'GSIs listed in the enclosure.
Please contact me if you have any questions or comments about the enclosed information.
Sincerely,
-ORIGINAL-SIGNED BY:
Paul O'Connor, Senior Project-Manager Project Directorate IV-1, Division of' Reactor Projects. III, IV, V.and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/ enclosure:
, r, n See next page
..- v DISTRIBUTION-EN T. Quay PD4-1 Reading File M. Virgilio MS13E4 NRC PDR L. Berry PD4 1 Plant File E. Jordan MBNN'3701' Local PDR P. O'Connor OCG-MS15B18 ACRS-(10)'MS P-315
~R. Scholl MS13E4 D. Miller MS14H20' q
OFC-
- PD4-1/LA......:........fg::PD4-1/D y
- PD4-1/PM
- P0'Connor:1h.:TQuay.p......:..............:..............:.............
......:......3
- NAME :LBerry DATE
- lD/$C/90
- 10 /3e/90
- U/s /90-0FFICIAL RECORD COPY Document Name: GENERIC SAFETY ISSUE COOPER 1
9011140218 9o1191 1
PDR ADOCK 05000298 pk P
f UNITED STATES
',g s, j gg y
NUCLEAR REGULATOR / COMMISSION
. WASHINGTON, D. C. 20555 -
,/
November 1, 1990
....+
Docket No. 50-298 Mr. George A. Trevors-Senior Staff Advisor - Nuclear Pon t Group Nebraska Public Power District Post Office Box 499 I
Columbus, Nebraska 68602-0499
Dear Mr. Trevors:
1
SUBJECT:
UNIMPLEMENTED GENERIC SAFETY '.SSUES AT COOPER NUCLEAR STATION 1
On April 25, 1990, the staff issued Generic letter 90-04 which requested information concerning the implementation status of certain generic safety issues (GSIs) at your facility.- Based on your response to this Generic-Letter, dated June 22, 1990, our own records, and discussions with your staff, we have updated our database on GSI. implementation status. The results of-this effort were presented to the Commission at a meeting on October 25, 1990.
The enclosure to this letter summarizes the staff's understanding of the i
current-status of those GSis which remain unimplemented at Cooper ~ Nuclear Station. We appreciate the assistance you provided in responding to Generic Letter 90-04 and we encourage your timely completion of those1GSis listed in
.l the enclosure.
Please contact me if you have any-questions or comments about the enclosed information.
Sincerely,.
.t Paul O'Connor, Senior Project Manager Project Directorate IV-1 Division of Reactor Projects - III, IV, V and Special Projects, Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/ enclosure:
See next page l
?
h s
J
.a M'r. George A. Trevors Nebraska Public Power District Cooper Nuclear Station
'1 CC:
i Mr. G. D. Watson, General Counsel j
l Nebraska Public Power District P. O. Box 499 4
Columbus, Nebraska 68602-0499 Cooper Nuclear Station ATTN: Mr. John M. Meacham Division Manager of Nuclear = Operations P. O. Box 98 1
Brownv111e, Nebraska 68321
]
l Dennis Grams, Director Nebraska Department of Environmental
- l Control P. O. Box 08922 Lincoln, Nebraska 68509-8922 Mr. Larry Bohlken, Cht'rman Nemaha County Board L-
"missioners
-l Nemaha-County Courthe s-1824 N Street Auburn, Nebraska 68305 Senior Resident inspector U.S. Nuclear Regulatory Connission P. O. Box 218 Brownville, Nebraska 68321 r
Regional Administrator, Region IV U.S. Nuclear..tegulatory Connission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Mr. Harold Borchert, Director Division of Radiological Health Nebraska Department of-Health 301 Centennial Mall, South P. O. Box 95007
.l p
Lincoln, Nebraska 68509-5007 l
l u
-l l
ENCLOSURE-3 b
UNIMPLEMENTED GSIs AT COOPER NUCLEAR STATION-PROJECTED IMPLEMENTATION-GSI NO.
TITLE DATE REMARKS 1 51 Improving the Reliability 12/21/91 NPPD has; proposed of Open-Cycle Service
-an acceptable Water Systems resolution for thistissue.and' will implement that resolution-by the end of.the next refueling outage.
67.3.3 Improved Accident TBD Neutron ~ flux Monitoring monitoring issue under appeal s
-l I
l i
'i 4
.i 1
l
.