r APPENDIX A NOTICE OF VIOLATION Tennessee. Valley Authority Docket No. 50-438 Bellefonte 1 License No. CPPR-122 As a result of the inspection conducted on May 1-31, 1982 and in accordance with the NRC Enforcement Policy, 47 FR 9987 (March 9, 1982), the following violation was identified.

10 CFR 50, Appendix B, Criterion V and Tennessee Valley Authority (TVA)

Final Safety Analysis Report, Section 17.1A.5 requires that activities affecting quality be accomplished in accordance with procedures and drawings.

"Bellefonte's sequence control chart SCC INR-M-004R1 paragraph 31 states:

Torque nut ring retainer bolts to five(s) ft-lbs."

Contrary to the above, on May 27, 1982, the resident inspector identified two (2) nut ring retainer bolts that were loose on control rod drive mechanisms CRDM #1209 and #1215. These nuts had previously been inspected by QC personnel.

This is a Severity Level IV Violation (Supplement II.E.1).

Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged viola-tion; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved. Consideration may be given to extending your response time for good cause shown.

Date:

820803023s 9207g9 PDR ADOCK 05000438 G

PDR L