ML20058F280

From kanterella
Jump to navigation Jump to search
Deficiency Rept Re Failure of Subsystem Ch Startup Flush to Remove Tape Matl Preventing Closure of Vol Control Tank Outlet Check Valve.Initially Reported on 820623.Deficiency Determined Not Reportable Per 10CFR50.55(e)
ML20058F280
Person / Time
Site: Palo Verde 
Issue date: 07/20/1982
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Bishop T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
10CFR-050.55E, 10CFR-50.55E, 82-32, ANPP-21443-GHD, DER-82-32, NUDOCS 8207300380
Download: ML20058F280 (2)


Text

-

1 Docket Nos.- 50-528/529/530 4 -

50.55(e) Report q.

[.}

NE@ N @@3EDDM STA.

3003 P.o. sox 21666 PHOENIX, ARIZONA 85036 July 20, 1982 ANPP-21443-CHD/BSK U. S. Nuclear Regulatory Commission Region V Creekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek, California.94596-5368 Attention:

Mr. T. W. Bishop, Chief Reactor Construction Projects Branch

Subject:

Deficiency Evaluation Report 82-32 A 50.55(e) Evaluation Relating to Startup Flush of Unit 1 Subsystem CH Failed to Remove Tape Material, Which Prevented Closure of VCT Outlet Check Valve.

File: 82-019-026 D.4.33.2

Reference:

Telephone Conversation between P, Narbut and G. Duckworth on June 23, 1982

Dear Sir:

The NRC was notified of the subject Deficiency Evaluation in the referenced telephone conversation, with a determination of reportability to be made within thirty (30) days (July 23, 1982).

The deficiency has subsequently been determined to be Not Reportable under the requirements of 10CFR50.55(e), therefore no written report is required.

Necessary documentation of the evaluation will be maintained in APS files.

Very truly yours, 1LL I N LLC E. E. Van Brunt, Jr.

APS Vice President Nuclear Projects ANPP Project Director EEVBJr/CHD:db i

cc: See Attached Page 2 g' lO g.

ud O '"

cNS$M

["C[

i 8207300380 820720 l

PDR ADOCK 05000528 l

_._,, _ _. _ P D R Q.f233 8

Jk U. S. Nuclear Regulatory Commission Attention:

Mr. T. W. Bishop, Chief July 20, 1982 ANPP-21443-GHD/BSK Page 2'

~

cc: Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulhtory Commission Washington, D. C. 20555 J. A. Roedel D. B. Fasnacht G. C. Andognini A. C. Rogers B. S. Kaplan W. E. Ide J. Vorees J. A. Brand A. C. Gehr W. J. Stubblefheld W. G. Bingham i R. L. Patterson R. W. Welcher R. M. Grant D. R. Hawkinson L. E. Vorderbrueggen G. A. Fiorelli Lynne Bernabei, Esq.

Harmon & Weiss 1725 "1" Street, NW Suite 506 Washington, D. C. 20006 R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 8703

.