June 9,1982 l

ST-H L-A E-839 l

FN G2.04/G15.01 l

(

Mr. John T. Collins Regional Administrator, Region IV Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012

Dear Mr. Collins:

South Texas Project Dockets Nos. 50-498, 50-499 This is in response to your letter 50-498/82-02, 50-499/82-02 dated June 3, 1982, relative to your investigation and resulting report pertaining to an allegation relative to the Quadrex Report.

Houston Lighting & Power Company has carefully reviewed the report and while we have no objection to NRC releasing the report to the Public Document Room and the Atomic Safety & Licensing Board, we have noted several typo-graphical errors which you may wish to correct prior to such release.

These corrections will assure that the report accurately reflects the certified state-ments of the HLSP persons interviewed.

Accordingly, we request that copies of this letter with our comments accompany distribution of the report by your office.

The following changes to the report are recommended in order to more accurately reflect the certified statements of persons interviewed during the course of the investigation:

1.

Page 4 --

7th line from the bottom, change the word "his" to "H LS P's".

16th and 18th lines from the bottom, change the word " timely" to " quick".

2.

Page 5 --

17th line from the bottom, the word "no" should be "NO" and in quotation marks.

20th line from the bottom, change the word " view" to " review".

3.

Page 8 --

7th line from the bottom of Mr. Frazar's interview, change the word "present" to "available".

2nd line from top of Mr. Sumpter's interview, the word "about" should be deleted.

2nd line from the bottom in Mr. Sumpter's interview, the word " discuss" should be; changed to " review".

8207300370 820616 PDR ADOCK 05000498 G

PDR

llouston Igiting &JbutT Company I <

Mr. John T. Collins June 9,1982 Page 2 ST-H L-AE-839 FN G2.04/G15.01 4.

Page 9 --

1st line in the top of the page, the word "nonengineering" should be changed to "known engineering".

8th line from the top of the page, the word " description" should be " descriptions".

20th line from the top, the word " discussed" should be deleted.

30th line from the top, insert the word " lead" between HLSP and engineers.

35th line from the top, change the words "other repre-sentatives" to the name of " Larry Wray".

5.

Page 10 -- Line 28, insert word "not" between was and maintained.

6.

Page 11 -- 7th line from the bottom, the word " interest" should read " interests"; insert the word "not" between would and be; and delete "best".

This series of words will now read " interests would not be served".

7.

Page 13 -- 2nd line from top, Dr. Key has not been identified as being a participant in the Quadrex Report, but we feel the words "Dr. Key" should be replaced with the word "he".

Should you have any questions concerning these changes, please contact me or Mr. J. H. Goldberg.

Very truly yours, Weof e' '.

a, J r'

Ex utive Vice esident GWO /sra