JUL 9 1382 DISTRIBUTION:

Document Controll(50-373);

NRC PDR Docket Nos.: 50-373/374 hSfC PRC LB#2 Reading EHylton ABournia CWoodhead, OELD Hr. Louis 0. De1 George I&E Director of Nuclear Licensing ACRS (16)

Commonwealth Edison Company Region III Post Office Box 767 RJBosnak Chicago, Illinois 60690 FCherney GHammer

Dear Mr. De1 George:

HCRockhold, EG&G/ Idaho

Subject:

Pump and Valve Inservice Testing Program - La Salle County Station, Units 1 and 2 Enclosed are questions which were developed as a result of the review of your pump and valve inservice testing program. This review was performed by EG&G under a technical assistance contract to NRC. To proceed with this review, we would like to arrange a working meeting at the La Salle site, and the enclosed questions would serve as the agenda for the meeting.

We would like to arrange this meeting for sometime during the week of August 23, 1982.

If you desire any clarification, please contact A. Bournia at (301) 492-3196.

Sincerely, v

A. Schwencer, Chief l

Licensing Branch No. 2 Division of Licensing

Enclosure:

As stated cc: See next page 8207300043 820709 PDR ADOCK 05000373 P

ppg

.D,L,;g,f,2fP,M,.D.

2/BC, orrice >

su m uc>..M9.uro,1,a,,: kw.AS,

, n,c e r,,

.....?L1/ 82....,

. 7/ / 82,,,,,

om>

Ec ronu sis oo-somscu ono OFFICIAL RECORD COPY usce mi-mm

La Salle Mr. Louis 0. De1 George Director of Nuclear Licensing Commonwealth Edison Company P. O. Box 767 Chicago, Illinois 60690 cc: Philip P. Steptoe, Esquire Suite 4200 One First National Plaza Chicago, Illinois 60603 Dean Hansell, Esquire Assistant Attorney General 188 West Randolph Street i

Suite 2315 Chicago, Illinois 60601 William G. Guldemond, Resident Inspector LaSalle NPS, U.S.N.R.C.

P. O. Box 224 Marseilles, Illinois 61364 Y

O 4

9 Valve Testing Program A.

General Comments and Questions 1.

Why was the 1974 Edition through Sumer '75 Addenda of ASME Section XI utilized for preparation ~ly the-LaSalle IST Program rather tSan the 1977 Edition?

2.

Are all valves that perform a pressure isolation function and containment isolation function leak rate tested to 10 CFR 50 Appendix J and Section XI requirements?

3.

Provide P&ID-M-93 Sheet 1 for our review at the working meeting.

4.

Are all check valves that receive the "E" exercise testing full stroke exercised at the specified frequency?

B.

Diesel Generator System 1.

Should Valve 10G-012 actually be 10G-002 as indicated on the P&IO7 2.

Valve 10G009.is indicated in' the valve listing on page 1 and 3.

Are these listings for the same valve?

C.

Feedwater System 1.

What is the safety related function of check valves 1821-F010A and 87 i

l

' 2.

How are the check Valves IB21-F032A and 8 partial stroke exercised during power operation.

D.

Containment Combustible Gas Control System i

1.

Is this system configuration the same for Unit I as for Unit 27 1

DESIGNATED ORIGINAL Certified By

a

.;e.
- - w 4..'.a w...#i...-, =n:.. e. A; G;.y.eg.._2,..,%.fyp,. d4,G.,,..

w.;a.,4. 3 E.

High Pressure Core Soray System 1.

Review the safety related functions of testable, check Valve IE22-F005 to determine if it should be categorized A/C.

"* 'a 2.

Review the safety related functions of Valve's IE22-F012 and lE22-F015 to determine if they should be categorized A.

3.

Provide the specific technical justification for not full or partial stroke exercising check Valve lE22-F016 quarterly and during cold shutdowns.

Is this valve full stroke exercised during refueling outages?

4 Review the safety related functions of relief Valves 1E22-F014

~

and lE22-F035 to determine if they should be categorized A/C.

5.

Is a check of valve position indicators performed per lWV-3300 for Valve lE22-F0387 6.

Review the safety related functions of the following valves to determine if they should be included in the IST program and categorized as indicated.

j Category A lE22-F354 (location C-6) i

-lE22-F023 (location C-4)

Category B l

lE22-F010 (location 0-4) l lE22-F0ll (location 0-3) l l

2 I

s\\

F.

Drywell Instrument Nitrogen System 1.

Provide the specific technical justification for not full stroke exercising the following valves during cold shutdowns.

IIN001A

. lIN074 IIN0018 lIN075 IIN017 2.

Provide the specific technical justification for not stroke timing the following valves.

l!N017 11N074

IIN075, 3.

Review the safety related function of Valve LINO 31 to determine if it should be categorized A.

Provide the specific technical justification for not stroke timing this valve.

4 Provide a more specific technical justification for not exercising check Valves 1821-F024 A, B, C, and D and 1821-F040 C, D, E, R, S, U, and V during cold shutdowns.

f 5.

Review the safety related function of Valves IIN100 and IIN101 to determine if they should be categorized A.

Provide the specific technical

  • justification for not full stroke exercising these valves during cold shutdowns.

6.

Review the safety related functions of the following valves to determine if they should be included in the IST program and categorized as indicated.

3

Category C 1821-F036 C (location 0-2) P&ID 66-02 IB21-F036 0 (location 0-4)

IB21-F036 E (location 0-7)

IB21-F036 R (location 0-7)

IB21-F036 5 (location 0-6) 1821-F036 U (location 0-2)

IB21-F036 V (location 0-4) lIN043 (location 0-5) PLIO 66-07 lIN044 (location 0-8)

G.

Low Pressure Core Soray System 1.

Review the safety related functions of the following valves to determine if they should be categorized as indicated.

Catego'ry A Category A/C lE21-F001 lE21-F006 lE21-F005 1E21-F018 IE21-F011 lE21-F031 2.

Is a check of valve position indicators performed per IWV-3300 for Valve lE21-F0517 3.

Review the safety related functions of Valves lE21-F012 I

and IE21-F333 (locations C-5 and C-7 respectively) to determine if they should be included in the IST program and categorized A.

H.

Main Steam System 1.

Review the safety related functions of the ADS safety / relief valves to determine if they should be categorized B/C.

I.

Primary Containment Vent & Purge System 1.

Why is the exercising frequency of Valve IVQO35 different from IVQO32?

e 4

2.

Is Valve IVQ068 ever open during power operation?

3.

Review the safety related function of the following valves to determine if they should be categorized A rather than B.

IVQ047

~~

~

IVQ048 IVQ050 IVQ051 IVQ042 i

IVQ043 4.

Review the safety related functions of the following valves to determine if they should be included in the IST program and

~

categorized as indicated.

Category A Category C 1CM012(locationC-6)

IPC001A (location 0-6)

ICM004 (location B-3) 1PC0018 (location E-6)

IPC001C.(location D-3)

IPC0010 (location E-3)

~

J.

Control Rod Drive Hydraulic System 1.

Review the safety related functions of Valves.lCll-F010 and ICll-F0li to determine if they should be categorized A.

2.

What is the Technical Specification CR0 scram testing frequency indicated in relief request RV-30?

3.

Review the safety related functions of Valves ICll-0001-115 and 1C11-D001-138 (locations D-7 and 0-5 respectively) to determine if they should be included in the IST program and categorized C.

4 Review the safety related functions of Valves ICll-F110A and B and ICll-F009 (locations B-7 and B-6 respectively) to determine j

if they should be included in the IST program and categorized B.

5 i

K.

Reactor Building Eculpment Orain System 4

1.

Are the following valves,always shut during power operation?

1RE024 1RF012 1RE025 1RF013 1RE026

~ ~.'a 1RE029 i

i t

L.

Residual Heat Removal System i

1.

Review the safety related functions of the following valves to determine if they should be categorized as indicated.

Category A Category A/C Category A/E lE12-F004A lE12-F025A lE12-F302 lE12-F016A lE12-F041A lE12-F017A lE12-F050A IE12-F027A lE12-F088A lE12-F042A lE12-F053A lE12-F064A j,'

1E12-F023 IE12-F024A 2.

Is a check of valve position indicators performed per IWV-3300 for Valves lE12-F092A and IE12-F090A?

i 3.

Review the safety related functions of Valves IE12-F099A and IE12-F327A (locations C-7 and E-7 respectively) to determine l

if they should be included in the IST program and categorized A.

4 4.

Review the safety related functions of the following valves to determine if they should be categorized as indicated.

f r

6 4

n-.

1 Category A Category A/C IE12-F0048 lE12-F0258 IE12-F0168 lE12-F030 lE12-F0178 lE12-F041B IE12-F027B lE12-F0508 lE12-F042B IE12-F0888

~

lE12-F0538 IE12-F0648 t-,

IE12-F0248 5.

Is a check of valve position indicators performed per IWV-3300 for Valves lE12-F0908 and lE12-F092B7 6.

Review the safety related functions of Valves IE12-F0998 and lE12-F3273 (locations C-7 and E-7 respectively) to determine if they should be included in the IST program and categorized A.

7.

Review the safety related functions of the following valves to determine if they should be categorized as indicated.

Category A Category A/C lE12-F004C 1E12-F005 i

lE12-F042C lE12-F025C 1E12-F064C lE12-F041C 1E12-F088C i

- B.

Is a check of valve position indicators performed per IWV-3300 for Valves 1E12-F092C and IE12-E0207 9.

Review the safety related functions of Valves 1E12-F021 and lE12-F327C to determine if they should be included in the IST program and categorized A.

10. Review the safety related functions of the following valves.to determine if they should be categorized as indicated.

t 7

Category A Category A/C lE12-F011A 1E12-F055A 1E12-F0llB IE12-F0558 lE12-F311A lE12-F3118

11. Review the safety related functions 0.f;the following valves to determine if they should be included in the IST program and categorized as indicated.

Category A 1E12-F073A (location E-3)

IE12-F0738 (location E-5)

Category B IE12-F065A (location B-2) lE12-F0658 (location A-7)

Category C 1E12-F089 (location F-5)

Category E 1FC040A (location E-7 P&ID M-87-02) 1FC042A (location E-7 P&ID M-87-02) 1FC045A (location E-6 PLID M-87-02)

IFC0408 (location D-7 P&ID M-87-01)

IFCO ;23 (location C-7 P&ID M-87-01)

IF'0458 (location C-6 P&ID M-87-01)

M.

Reactor Core Isolation Coolant System I

1.

Provide a more detailed technical basis for not full stroke l

exercising Valve IE51-F064 during power operation.

l 2.

Review the safety related functions of Valves lE51-F068 and lE51-F069 to determine if they should be categorized A.

8

3.

Review the safety related function of Valves lE51-F025 and IE51-F026 (location D-6) to determine if they should be included in the IST progcam and categorized B.

4 Review the safety related functions of the following valves to determine if they should be categorffed as indicated.

Category A Category 8 lE51-F013 lE12-F036A lE51-F019 IE12-F0368 IE51-F031 lE51-F066 5.'

Provide a more detailed technical justification for not full stroke exercising IE51-F013 during power operation.

6.

Is check Valve IE51-F030 full stroke exercised quarterly?

7.

Review the safety related functions of the following valves to determine if they should be included in the IST program and categorized as indicated.

Category A lE51-F355 (location C-8)

Category 8 lE51-F022 (location E-6) lE51-F059 (location E-5)

Category C lE51-F021 (location B-4)

N.

Nuclear Boiler and Reactor Recirculating System 1.

Do the excess flow check valves on the instrument lines for this system provide a containment isolation function?

9

)

s P.

Reactor Water Clean-UD System 1.

Is this system required to be in operation at all times during power operation?

Q.

Standby Liquid Control System 1

Provide a more detailed technical justification for not full stroke exercising Valves IC41-F001A and 8 during cold shutdown.

2.

Provide a more detailed technical justification for not full stroke exercising check Valves IC41-F006 and IC41-F007 during cold shutdown.

3.

Is a check of valve position indicators performed per IWV-3300 for Valve IC41-0087 R.

Primary Containment Chilled Water System 1.

Provide a more detailed technical justification for not full stroke exercising all valves indicated on relief request RV-17 during cold shutdown.

S.

Containment Monitoring System 1.

Review the safety related function of the following valves to dete.rmine if they should be included in the IST program and categorized as indicated.

(

i e

10

1 Category A j

ICM017A (location F-7, P&ID M-156-01)

ICM018A (location E-7, P&ID M-156-01) 1CM019A (location B-7, P&ID M-156-01)

ICM020A (location B-7, P&ID M-156-01)

ICM022A (location E-3, P&ID M-156-01)

ICM024A (location E-3, P&ID M-156-01) 1CM025A (location A-4, P&ID M-IS6 01),

4 ICM0178 (location F-7, P&ID M-156-02)

ICM0183 (location F-7, P&ID M-156-02) 1CM0198 (location 8-7, P&ID M-156-02)

ICM0208 (location B-7, P&ID M-156-02)

ICM0218 (location E-3, P&ID M-156-02)

ICM0238 (location E-3, P&ID M-156-02) 1CM026B (location A-4, P&ID M-156-02)

ICM031 (location C-6, P&ID M-156-04) 1CM032 (location C-6, P&ID M-156-04)

ICM033 (location B-7, P&ID M-156-04)

ICM034 (location B-7, P&ID M-156-04)

~

e 4

i I

i l

l l

l l

l i.

i f

11 l

1 Pumo Testing Program 1.

The current NRC position on IST pump testing frequency is the pumps be started and one parameter cbserved to verify satisf actory operation monthly and the complete Section XI specified test performed quarterly.

'~

4

=

b G

e 12